residential building application – prefabricated house ... fileeasysens® example – room layout...

13
Residential building Application – Prefabricated house with 2 floors –

Upload: others

Post on 26-Sep-2019

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Residential building Application – Prefabricated house ... fileEasySens® Example – Room Layout Residential building Application – prefabricated house with 2 floors

Residential building Application – Prefabricated house with 2 floors –

Page 2: Residential building Application – Prefabricated house ... fileEasySens® Example – Room Layout Residential building Application – prefabricated house with 2 floors

EasySens® Example – Room LayoutResidential building Application – prefabricated house with 2 floors

Page 3: Residential building Application – Prefabricated house ... fileEasySens® Example – Room Layout Residential building Application – prefabricated house with 2 floors

EasySens® Example – Room LayoutResidential building Application – prefabricated house with 2 floors

Switch MiniLight & Blind

Switch MiniLight & Blind

Switch MiniLight

Switch MiniLight & Blind

Switch MiniLight & Blind

Switch MiniLight

Switch MiniLight & Blind

Switch MiniLight & Blind

Switch MiniLight & Blind

Switch MiniLight & Blind

Switch MiniLight

» underfloor heating

Switch MiniLight

Switch MiniLight

Switch MiniLight

Switch MiniLight & Blind

Switch MiniLight

Switch MiniLight

Switch MiniLight

Switch MiniLight

Switch MiniLight

Roomtemperature

sensor

Roomtemperature

sensor

Roomtemperature

sensor

Roomtemperature

sensor

Roomtemperature

sensor

Roomtemperature

sensor

Roomtemperature

sensor

Roomtemperature

sensor

» lighting dimmable » lighting switchable » socket switchable

Page 4: Residential building Application – Prefabricated house ... fileEasySens® Example – Room Layout Residential building Application – prefabricated house with 2 floors

EasySens® Example – FunctionalityResidential building Application – prefabricated house with 2 floors

Blinds underfloorheating

socket switchable

Lights(groups)

Dim(groups)

Ground Kitchen / living room 2 1 3 1floor Guest bathroom 1 1 1

Office 1 1 1Utility Room 1 1 1Floor (Ground floor) 1 1

Top Master bedroom 1 1 2 1 1floor Children's room 1 1 1 1 1 1

Children's room 2 1 1 1 1 1Guest bathroom 1 1 1Floor (Top floor) 1

Total 10 8 4 12 4Total data points 20 8 4 12 4

DO DO DO DO AO

Page 5: Residential building Application – Prefabricated house ... fileEasySens® Example – Room Layout Residential building Application – prefabricated house with 2 floors

Operation / Controls

HVAC Lights Blinds Scenes

Outputs

EasySens® Example – SolutionResidential building Application – prefabricated house with 2 floors

OPERATION (TRANSMITTERS) QTY Remark

SR07PTemperature room unit with setpoint potentiometer

8

Mini 2-ch Light 2-channel light switch; pure white brilliant 3

Mini 4-ch Light 4-channel light switch; pure white brilliant 8

Mini 4-ch Light/Blinds2-channel light, 2-channel blinds switch; pure white brilliant

9

OUTPUTS (RECEIVERS)

STC-DO8 Digital ouput module with 8 DO's (Type 3) 3all lights,

blinds

STC-DO8 Digital ouput module with 8 DO's (Type 1) 1 floor heating

STC-PLUS 4DO Digital output add-on module for STC-DO8 2

STC-ADO Universal (DO/AO) output module 10-10VDC setpoint

Page 8: Residential building Application – Prefabricated house ... fileEasySens® Example – Room Layout Residential building Application – prefabricated house with 2 floors

EasySens® Example – Panel WiringResidential building Application – prefabricated house with 2 floors

» Wiring „heating“

Heating H1 Heating H2 Heating H3 Heating H4 Heating H5 Heating H6 Heating H7 Heating H8

FUSE

N +

POWER SUPPLY

LL 24

VDC-

N

STC-DO8 Typ124V GND

1NC 1NO 1C 2NC 2NO 2C 7NC 7NO 7C5NC 5NO 5C 6NC 6NO 6C3NC 3NO 3C 4NC 4NO 4C 8NC 8NO 8C

R7 R8R1 R2 R3 R4 R5 R6

Page 9: Residential building Application – Prefabricated house ... fileEasySens® Example – Room Layout Residential building Application – prefabricated house with 2 floors

EasySens® Example – Panel WiringResidential building Application – prefabricated house with 2 floors

» Wiring „lights“

Lights L1 Lights L2 Lights L3 Lights L4 Lights L5 Lights L6 Lights L7 Lights L8 Lights L9 Lights L10 Lights L11 Lights L12

FUSE

R12R11R10R9R7 R8R2R1 R5

POWER SUPPLY

R4R3

LN

L 24 VDC

-N +

BNC BNO6C 7NC 7NO5NC 5NO 5C 6NC 6NO DC

STC-DO8 Typ3 STC-PLUS 4DO24V GND

BC CNC CNO CC DNC DNO8C ANC ANO AC2C 3NC 3NO 3C 4NC 4NO1NC 1NO 1C 2NC 2NO 7C 8NC 8NO4C

R6

Page 10: Residential building Application – Prefabricated house ... fileEasySens® Example – Room Layout Residential building Application – prefabricated house with 2 floors

EasySens® Example – Panel WiringResidential building Application – prefabricated house with 2 floors

» Wiring „blinds“

N DW UP N DW UP N DW UP N DW UP

N1 N1

L1 L1

NO C NO C NO C NO C

NC NC

L1

N1

E E E N DW UP E

Blind 1 Blind 1

E E N DW UP

Cut-off relay TR1 Cut-off relay TR21N 2N 1DW 2DW 1UP 2UP1N 2N 1DW 2DW 1UP 2UP

R1 R2 R7 R8

1NC 1NO 1C 2NC 2NO 2C 3NC 3NO 8NO 8C

STC-DO8 Typ3POWER SUPPLY

GND 24V

5C 6NC 6NO 6C 7NC 7NO3C 4NC 4NO 4C 5NC 5NO 7C 8NC

Blind 4

2UP

L Fused

Breake

rL 24

VDC-

NN +

Cut-off relay TR7 Cut-off relay TR81N 2N 1DW 2DW 1UP

Blind 4

E E E N DW UP E E E

1N 2N 1DW 2DW 1UP 2UP

N DW UP

Page 11: Residential building Application – Prefabricated house ... fileEasySens® Example – Room Layout Residential building Application – prefabricated house with 2 floors

EasySens® Example – Panel WiringResidential building Application – prefabricated house with 2 floors

» Wiring „sockets (dim)“Socket S1 Socket S2 Socket S3 Socket S4

L1

N1

Dim Dim Dim Dim Light L1 Light L9 Light L10 Light L11

SRC-ADO 4AA / 4DA6 C 7

AO48 C1

AO12 C 3

AO24 C

17C 18NC 19NO 20C

L Fused

Breake

rL 24

VDC-

NN +

5 AO3

POWER SUPPLYGND 24V

9NC 10NO 11C 12NC 13NO 14C 15NC 16NO

R1 R2 R3 R4

Page 12: Residential building Application – Prefabricated house ... fileEasySens® Example – Room Layout Residential building Application – prefabricated house with 2 floors

EasySens® Example – Devices (overview)Residential building Application – prefabricated house with 2 floors

Page 13: Residential building Application – Prefabricated house ... fileEasySens® Example – Room Layout Residential building Application – prefabricated house with 2 floors

Please visit us online www.thermokon.comMany thanks for your attention!

This presentation document is solely made up for internal use by the management and the employees. Distribution, reproduction andcitation to third parties – even excerpts from this presentation – are forbidden and only allowed after explicit consent of Thermokon

Sensortechnik. Violations will be prosecuted by copyright.