report wizard main function report set head form waveformcorrelation description test plan add a new...

25
Report Wizard Main Report Wizard Main Function Function Add a new Header report item to place the title, parameter or logo for completeness in the report you wish to generate.

Upload: timothy-daniels

Post on 03-Jan-2016

214 views

Category:

Documents


0 download

TRANSCRIPT

Report Wizard Main FunctionReport Wizard Main Function

Add a new Header report item to place the title, parameter or logo for completeness in the report you wish to generate.

Report Wizard Main FunctionReport Wizard Main FunctionTo display the test conditions, readings or test results during report generation.Present the data in a table.Except waveform.

Report Wizard Main FunctionReport Wizard Main FunctionPresent the waveform in a table.Except waveform and correlation.

Report Wizard Main FunctionReport Wizard Main Function

X - X - AxisAxis

11 22 33…………

Y - Y - AxisAxis

2.22.211

5.35.322

1.11.199

…………

Plot charts of the array type data

Report Wizard Main FunctionReport Wizard Main Function

OVERSHOOT AT START-UPTest conditions:Outputs at load condition 1 per section 2.1. Input voltage at 264VAC.Pass/Fail criteria: The 3.3V and 5V outputs shall not exceed 3.7V and 5.4V during start-up

OVERSHOOT AT START-UPTest conditions:Outputs at load condition 1 per section 2.1. Input voltage at 264VAC.Pass/Fail criteria: The 3.3V and 5V outputs shall not exceed 3.7V and 5.4V during start-up

OVERSHOOT AT START-UPTest conditions:Outputs at load condition 1 per section 2.1. Input voltage at 264VAC.Pass/Fail criteria: The 3.3V and 5V outputs shall not exceed 3.7V and 5.4V during start-up

OVERSHOOT AT START-UPTest conditions:Outputs at load condition 1 per section 2.1. Input voltage at 264VAC.Pass/Fail criteria: The 3.3V and 5V outputs shall not exceed 3.7V and 5.4V during start-up

Report Wizard Main FunctionReport Wizard Main FunctionA special form to edit quickly.

Report Wizard Main FunctionReport Wizard Main FunctionReport item sequence.Generate reports.Document setting

Principle of Report Wizard Principle of Report Wizard

AA@@@.@@@.@@@@

B B @@.@@@.@@ @

CC @@@@@@@@

AA@@@@@@@@@@

B B @@@@@@@@@@

CC @@@@@@@@

AA 123.45123.45

B B 67.8967.89

CC PASSPASS

AA 1234512345

B B 67896789

CC PASSPASS

Before Test

After Test

Test report include tow elements, report items and log data.

“ Start the Report Wizard ”

Start the Report WizardStart the Report Wizard

Report Activity Flow

Generate

Head 、 Form 、 Waveform 、 Test Plan :New → Edit → Preview → Save → ReleaseDescription 、 Report Set :New → Edit → Save → ReleaseReport Set Generate :Select UUT NO → Generate report

HeadHead

Setting Header:1.Editing text 2.Inserting Image 3.Setting Option: Serial No Environment System Time Model Name Inspector Retest Time Lot Number Customer Order Number Elapsed Time

New → Edit → Preview → Save → Release

FormForm

By Test Item By Test Item By TI Group By TI Group By Sequence By Sequence Free Format Free Format

Form(By Sequence) Form(By Sequence) Free Format Free Format

Form(BY TI) Form(BY TI)

New → Edit → New → Edit → Preview → Save → Preview → Save → ReleaseRelease

Report Editing Mode.Report Editing Mode.Variable Setting Mode .Variable Setting Mode .To generate new form for this report item.To generate new form for this report item.To load the existing report format .To load the existing report format .To save the current report format but not To save the current report format but not variable settings.variable settings.

To define a Test Item Group.To define a Test Item Group.

Form-ToolbarForm-Toolbar

Form-ToolbarForm-Toolbar

To specify the range for variable settings. To specify the range for variable settings.

To clear the specified variable range. This action will To clear the specified variable range. This action will clear all variables that set in the range. clear all variables that set in the range.

Set variable: Specify the cell variable in variable setting Set variable: Specify the cell variable in variable setting mode. mode.

Clear variable: To clear the cell variable in variable Clear variable: To clear the cell variable in variable setting mode. setting mode.

Form-ToolbarForm-Toolbar

Cut: To cut the selected area without variable Cut: To cut the selected area without variable information in report editing mode. information in report editing mode.

Copy: To copy the selected area without variable Copy: To copy the selected area without variable information in report editing mode. information in report editing mode.

Paste: To paste the copied data without variable Paste: To paste the copied data without variable information in report editing mode. information in report editing mode.

Form-ToolbarForm-Toolbar

Merge the cell: To merge the selected cells. Merge the cell: To merge the selected cells. Cancel the cell merge: To cancel merging the selected cells. Cancel the cell merge: To cancel merging the selected cells.

Add a new row: To add a new row at the end of the report. Add a new row: To add a new row at the end of the report. Insert a new row: To insert a new row at the current row. Insert a new row: To insert a new row at the current row. Delete a row: To delete the current row. Delete a row: To delete the current row.

Add a new column: To add a new column at the rightmost of the Add a new column: To add a new column at the rightmost of the report. report.

Insert a new column: To insert a new column at the current column. Insert a new column: To insert a new column at the current column.

Delete a column: To delete the current column. Delete a column: To delete the current column.

FormFormBy By TI TI NameName

By By GroupGroup

By By SequenSequencece

Free & Free & By By SequenSequencece

Free & Free & By TI By TI NameName

Different Different TI Name TI Name in the in the same same form.form.

VariableVariables must in s must in the same the same row. row.

Array Array can auto can auto expand.expand.

The The variables variables in the in the same TI same TI can auto can auto expand.expand.

WaveformWaveformSupport data type:Picture

Support data format:•PCX•BMG•GIF•JPG

Condition Setting:To set the position order.

CorrelationCorrelationSupport data type:Support data type:

Float and integer ArrayFloat and integer Array

Condition Setting:Condition Setting:

To set the position orderTo set the position order..

DescriptionDescription

TestPlanTestPlan

Report SetReport Set

“ Thanks for your attended”