replace roofs, multiple buildings montgomery city youth center … · 2020-03-03 · line of roof...
TRANSCRIPT
SHEET NUMBER:
OWNER:
PROJECTMANAGEMENT:
DESIGNER:
SITE NUMBER: (7709)(8877709007), (8877709008)(8877709009), (8877709010)(8877709011), (8877709012)(8877709013)
ASSET NUMBERS:
PROJECT NUMBER: H1908-01
WoolpertSTATE OF MISSOURIMichael L. Parson,GOVENOR
DEPARTMENT OF SOCIAL SERVICES DIVISION OF YOUTH SERVICES
OFFICE OF ADMINISTRATIONDIVISION OF FACILITIES MANAGEMENT,DESIGN AND CONSTRUCTION
Replace Roofs, Multiple BuildingsMontgomery City Youth Center
Division of Youth Services
1 OF 6 SHEETS
July ?, 2019
3636 South Geyer RoadSuite 100St. Louis, MO 63127314.436.0865FAX: 314.471.0664
BID DOCUMENTS 06 NOVEMBER 2019
CERTIFICATE OF AUTHORITY NUMBER:
G-001
F00623916
1 OF 6 SHEETS
COTTAGE UNIT "D"
COTTAGE UNIT "C"
COTTAGE UNIT "B" COTTAGE UNIT "A"VOTEC BLDG
MAINT. BLDG
CORE/MULTIPURPOSE/GYMNASIUM BLDG
BUILDING SECTION
DETAIL/ENLARGED PLAN
EXTERIOR ELEVATIONS
DRAWING TITLE
DRAWING REFERENCE NUMBER
DRAWING SHEET NUMBER
END OF SECTION
DRAWING SHEET NUMBER
DRAWING REFERENCE NUMBER
DRAWING REFERENCE NUMBER
DRAWING SHEET NUMBER
SCALE OF DRAWING
DRAWING TITLE
DRAWING SHEET NUMBER
WALL SECTION
END OF SECTION
DRAWING SHEET NUMBER
DRAWING REFERENCE NUMBER
INTERIOR ELEVATIONS
DRAWING REFERENCE NUMBER
DRAWING SHEET NUMBER
A1
A1
A-101
A-101
A1
A-101
A1
A-101
A-101
A1
SIM
SIM
A1SCALE: 1/8" = 1'-0"
View Name
A
A/C
ADD.
ADJ.
A.F.F.
AGG.
ALUM.
ALT.
APPROX.
ARCH.
ASPH.
AIR CONDITION(ING)
ADDENDUM, ADDITIONAL
ADJACENT, ADJUSTABLE
ABOVE FINISH FLOOR
AGGREGATE
ALUMINUM
ALTERNATE
APPROXIMATE
ARCHITECTURE(URE)(URAL)
ASPHALT
B
BC
BD.
BK.
BLDG.
BLKG.
BM.
BORDER CARPET
BOARD
BRICK
BUILDING
BLOCKING
BEAM
C
C.F.
C.J.
CLG.
C.M.U.
CONC.
CONF.
CONST.
CONT.
C.T.
C.P.
CUBIC FEET
CONTROL JOINT
CEILING
CONCRETE MASONRY UNIT
CONCRETE
CONFERENCE
CONSTRUCTION
CONTINUOUS, CONTINUED
CERAMIC TILE
CARPET
C.Y. CUBIC YARD
D
DWG. DRAWING(S)
E
E. EAST
EA. EACH
E.J. EXPANSION JOINT
ELEC. ELECTRIC, ELECTRICAL
ELEV. ELEVATION, ELEVATOR
ENGR. ENGINEER(ING)(ED)
ERD. EXISTING ROOF DRAIN
EQ. EQUAL
EQUIP. EQUIPMENT
E.W. EACH WAY
E.W.C. ELECTRIC WATER COOLER
EXIST. EXISTING
EXP. EXPOSE(ED), EXPANSION
EXT. EXTERIOR
EX ST EXPOSED STRUCTURE
G
GAL. GALLON
GALV. GALVANIZED
G.B. GLASS BLOCK
G.C. GENERAL CONTRACTOR
GL. GLASS
GYP. GYPSUM BOARD
H
H.B. HOSE BIB
H.C. HOLLOW CORE
HDW. HARDWARE
HDWD. HARDWOOD
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
H.&V. HEATING & VENTILATING
I
I.D. INSIDE DIAMETER
INSUL. INSULATION, INSULATED
INT. INTERIOR
J
JCT. JUNCTION
JST. JOIST
L
LB. POUND
L.F. LINEAL FEET
LAM. LAMINATED
LAV. LAVATORY
M
MATL. MATERIAL
MAX. MAXIMUM
MECH. MECHANICAL
MEZZ. MEZZANINE
MFR. MANUFACTURE(ER)(ED)
MIN. MINIMUM
MTG. MEETING
M.O. MASONRY OPENING
N
N.
N.I.C.
NORTH
NOT IN CONTRACT
O
O.C.
O.D.
ON CENTER
OUTSIDE DIAMETER
OFF.
O.F.O.W.
OFFICE
OUTSIDE FACE OF WALL
OH.
OPNG.
OVERHEAD
OPENING
OPP. OPPOSITE
P
P.
PAV.
PAINT(ED)
PAVED, PAVEMENT
PL.
PLMB.
PLASTIC, PLASTER
PLUMB(ING)
PLYW.
P.S.F.
PLYWOOD
POUNDS / SQUARE FOOT
P.S.I. POUNDS / SQUARE INCH
P.T.
P.T.D.
PORCELAIN TILE
PAPER TOWEL DISPENSER
PVC. POLYVINYLCHLORIDE
Q
Q.T. QUARRY TILE
R
REINF.
REQ.
REINFORCE(ED)(ING)
REQUIRE(ED)
RESIL.
RES.
RESILIENT
RESINOUS FLOORING
RM. ROOM
S
S.
S.A.T.
SOUTH
SUSPENDED ACOUSTICAL TILE
S.C.
SECT.
SOLID CORE
SECTION
S.F.
S.G.T.
SQUARE FEET
STRUCTURAL GLAZED TILE
S.N.D. SANITARY NAPKIN DISPENSER
SPKLR.
STD.
SPRINKLER
STANDARD
STL. STEEL
STRUCT. STRUCTURE, STRUCTURAL
SIM. SIMILAR
T
TEL.
TEMP.
TELEPHONE
TEMPORARY, TEMPERATURE
TERR.
T.O.C.
TERRAZZO
TOP OF CONCRETE
TOIL.
T.O.S.
TOILET
TOP OF STEEL
T.O.W. TOP OF WALL
TV. TELEVISION
U
UNF.
UR.
UNFURNISHED
URINAL
UTIL. UTILITY, UTILITIES
V
V.B.
V.C.T.
VAPOR BARRIER
VINYL COMPOSITION TILE
VENT.
VEST.
VENTILATOR, VENTILATION
VESTIBULE
V.P.
V.T.
VENEER PLASTER
VINYL TILE
V.T.B. VINYL TILE BASE
V.W.C. VINYL WALL COVERING
W
W.
W.C.
WEST
WATER CLOSET
WD.
WT.
WOOD
WEIGHT
D.S. DOWNSPOUT
RTU ROOF TOP UNIT
F
FT FEET
TYP. TYPICAL
SHEET NUMBER:
3636 South Geyer Road Suite 100St. Louis, MO 63127314.436.0865FAX: 314.471.0664
ARCHITECTURE ENGINEERING GEOSPATIAL
STATE OF MISSOURIMICHAEL L. PARSON,GOVENOR
PROFESSIONAL SEAL
OFFICE OF ADMINISTRATION DIVISION OF FACILITIES MANAGEMENT,DESIGN AND CONSTRUCTION
DEPARTMENT OF PUBLIC SAFETY, OFFICE OF THE ADJUTANT GENERAL MISSOURI NATION GUARD
INDEX OF DRAWINGS LOCATION MAP
KEY PLANSYMBOLSABBREVIATIONS
2 OF 6 SHEETS
00/00/0000
SHEET TITLE:
DESIGNED BY:
DRAWN BY:
CAD DWG FILE:
CHECKED BY:
REVISION:
DATE:
REVISION:
ISSUE DATE:
REVISION:DATE:
DATE:
SITE #
PROJECT #
ASSET #
REPLACE ROOFS, MULTIPLE BUILDINGS MONTGOMERY CITY YOUTH CENTER DIVISION OF YOUTH SERVICES
H1908-01
7709
(8877709007), (8877709008)(8877709009), (8877709010)(8877709011), (8877709012)(8877709013)
BID DOCUMENTS 06 NOVEMBER 2019
BIM
360://S
tate
of M
issouri/M
on
tgom
ery
City Y
outh
Cente
r_A
RC
H_
R19.r
vt
11/7
/201
9 1
0:2
0:1
0 A
M
G-002
INDEX OF DRAWINGS,LOCATION MAP &ABBREVIATIONS
SheetNumber Sheet Name
G-001 COVER
G-002 INDEX OF DRAWINGS, LOCATION MAP & ABBREVIATIONS
AD-001 OVERALL DEMOLITION ROOF PLAN
A-100 OVERALL ROOF PLAN
A-200 ROOF DETAILS
A-201 ROOF DETAILS
PROJECT LOCATION
LOCATION MAPREGIONAL MAP
SCALE : 1" = 30'-0"1 ROOF LEVEL (WORK AREA)
SITE ADDRESS: 300 NIEDERGERKE DRIVE MONTGOMERY CITY, MO 63361
06 NOVEMBER 2019
UNISEX HOUSING UNIT "B" ROOF PLAN UNISEX HOUSING UNIT "A" ROOF PLANVOTEC BUILDING
UNISEX HOUSING UNIT "C" ROOF PLAN
COED HOUSING UNIT "D" ROOF PLAN
CORE/MULTIPURPOSE/GYMNASIUM BUILDING ROOF PLAN
MAINTENANCE BUILDING
106106106
001001001001
001001001001001001
001001001001
001001001001 001001001001
001001
001001001001
001001
COMPLETELY REMOVE ANTENNAS AND SATELLITE DISHES WHICH ARE NO LONGER IN USE FROM BUILDING
COMPLETELY REMOVE ANTENNAS AND SATELLITE DISHES WHICH ARE NO LONGER IN USE FROM BUILDING
REMOVE EXISTING CAPPED FLUE BELOW ROOF DECK
REMOVE EXISTING ROOF STRAINER BASKETS
REMOVE EXISTING ATTIC VENTS FOR REPLACEMENT WITH NEW. TYP
D.S
D.S.D.S.D.S.D.S.D.S.
D.S. D.S. D.S.
D.S.
D.S.
D.S.D.S.
D.S.
D.S.
D.S.
D.S. D.S.
D.S.
D.S.
D.S.
D.S.
D.S.
D.S.
D.S.
104
104
104
104
104
104
TYP.
TYP.
TYP.TYP.
TYP.
TYP.
TYP.
104
104
TYP.
EXISTING MINI-SPLIT HVAC UNIT ON EXISTING ROOFING
REMOVE EXISTING 4x4 PRESSURE TREATED WOOD BLOCK SUPPORTS UNDER CONDENSING UNITS AND PREPARE TO BE REPLACED WITH NEW
D.S.
D.S.
D.S.
D.S.
D.S.D.S.
D.S.
D.S. D.S.
D.S.
D.S.
D.S.
D.S.
D.S.
D.S. D.S.
D.S.
D.S.
D.S.
D.S.
D.S.
D.S. D.S.
D.S.
D.S.
D.S.
D.S.
D.S.
D.S.
REMOVE 4 SCREWS HOLDING MOUNTING BRACKETS OF DISCONNECT PANEL TO PARAPET WALL FOR REMOVAL OF EXISTING EPDM AND INSTALL OF NEW PVC MEMBRANE
REMOVE EXISTING METAL WATER HEATER EXHAUST VENT PIPE FOR REPLACEMENT WITH PVC PIPE
SHEET NUMBER:
3636 South Geyer Road Suite 100St. Louis, MO 63127314.436.0865FAX: 314.471.0664
ARCHITECTURE ENGINEERING GEOSPATIAL
STATE OF MISSOURIMICHAEL L. PARSON,GOVENOR
PROFESSIONAL SEAL
OFFICE OF ADMINISTRATION DIVISION OF FACILITIES MANAGEMENT,DESIGN AND CONSTRUCTION
DEPARTMENT OF PUBLIC SAFETY, OFFICE OF THE ADJUTANT GENERAL MISSOURI NATION GUARD
2 OF 6 SHEETS
00/00/0000
SHEET TITLE:
DESIGNED BY:
DRAWN BY:
CAD DWG FILE:
CHECKED BY:
REVISION:
DATE:
REVISION:
ISSUE DATE:
REVISION:DATE:
DATE:
SITE #
PROJECT #
ASSET #
REPLACE ROOFS, MULTIPLE BUILDINGS MONTGOMERY CITY YOUTH CENTER DIVISION OF YOUTH SERVICES
H1908-01
7709
(8877709007), (8877709008)(8877709009), (8877709010)(8877709011), (8877709012)(8877709013)
BID DOCUMENTS 06 NOVEMBER 2019
AD-001
OVERALL DEMOLITION ROOFPLAN
SCALE : 1/16" = 1'-0"1 OVERALL DEMOLITION ROOF PLAN11. CONTRACTOR SHALL COMPLETELY REMOVE ALL ROOFING NAILS FROM GROUNDS EACH DAY.
10. PRIOR TO REMOVAL AND RELOCATION OF ANY ELECTRICAL LINES AND GAS LINES, TURN OFF ELECTRIC AND
GAS SERVICES AS REQUIRED.
9. EVERY ATTEMPT HAS BEEN MADE TO LOCATE AND IDENTIFY ALL ROOF PENETRATIONS AND ROOF TOP
UNITS. G.C. SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL ROOF PENETRATIONS AND ROOF TOP UNITS
PRIOR TO BIDDING, SO THAT BID CONTAINS ALL REQUIRED PRICING TO COMPLETE JOB. ALL FLASHING...
8. REMOVE ALL EXISTING ROOFING AND INSULATION DOWN TO EXISTING DECK.
7. AT ANY TIME DURING CONSTRUCTION, IF ANY CONTRACTOR DISCOVERS HAZARDOUS MATERIALS, STOP
WORK AND NOTIFY THE OWNER IMMEDIATELY.
6. CUT AND REMOVE PORTIONS OF EXISTING CONSTRUCTION AS REQUIRED TO ALLOW FOR PROPER
INSTALLATION OF NEW CONSTRUCTION.
5. NEITHER THE OWNER NOR USING AGENCY ASSUMES ANY RESPONSIBILITY FOR ACTUAL CONDITIONS OF
ITEMS TO BE DEMOLISHED.
4. ALL MATERIALS NOT REQUIRED TO BE REMOVED FOR THE EXECUTION OF THE PROJECT SHALL BE LEFT IN
PLACE AND PROTECTED FROM DAMAGE DURING CONSTRUCTION. ANY ITEMS DAMAGED DUE TO THIS
PROJECT SHALL BE RESTORED TO THEIR ORIGINAL CONDITION AT THE CONTRACTOR'S EXPENSE.
3. CONTRACTORS SHALL COMPLETELY REMOVE ALL DEMOLISHED MATERIALS FROM THE SITE. ALL
DEMOLISHED MATERIALS SHALL BECOME PROPERTY OF THE CONTRACTOR UNLESS THEY ARE TO BE
REUSED, OR AS OTHERWISE NOTED OR INSTRUCTED, AND TO BE DISPOSED OF LEGALLY. REMOVE DEBRIS,
RUBBISH, AND OTHER MATERIALS DAILY FROM CONSTRUCTION SITE. ALL REMOVED MATERIALS SHALL BE
DISPOSED OF LEGALLY. DO NOT STORE ANY DEMOLITION MATERIAL ON THE EXISTING ROOF.
2. CONTRACTOR TO VERIFY SIZE, QUANTITY AND LOCATION OF ALL EXISTING ROOF PENETRATIONS.
1. CONTRACTOR SHALL FIELD VERIFY DIMENSIONS AND BE RESPONSIBLIE FOR THE SAME. ANY DISCREPENCIES
SHALL BE BROUGHT TO THE ARCHITECT'S PRIOR TO FABRICATION AND/OR INSTALLATION.
DEMOLITION GENERAL NOTES:
001 REMOVE EXISTING ASPHALT SHINGLES ANDFELTS DOWN TO PLYWOOD SHEATHINGAND PREPARE FOR NEW ROOFINGMATERIALS. DOCUMENT ANY DAMAGEDSHEATHING ON DRAWINGS WITH PICTURESAND REPORT THE AMOUNT REQUIRINGREPLACEMENT TO OWNER'S ON SITEREPRESENTATIVE. TRACK QUANTITY FOREACH BUILDING.
104 REMOVE EXISTING GUTTERS ANDDOWNSPOUTS AND PREP FOR NEWGUTTERS AND DOWNSPOUTS IN SAMELOCATIONS.
106 NEW ASPHALT SHINGLE, OVER NEW #30FELT AND ICE DAM, OVER EXISTINGPLYWOOD ROOF SHEATHING
REFERENCE KEYNOTES:
3 OF 6 SHEETS
06 NOVEMBER 2019
UNISEX HOUSING UNIT "B" ROOF PLAN UNISEX HOUSING UNIT "A" ROOF PLAN VOTEC BUILDING
UNISEX HOUSING UNIT "C" ROOF PLAN
COED HOUSING UNIT "D" ROOF PLAN
CORE/MULTIPURPOSE/GYMNASIUM BUILDING ROOF PLAN
57' - 8"
75
' -
0"
57' - 8"
75
' -
0"
30
' -
3"
34' - 3"
9' -
0"
12
' -
3"
9' -
0"
37
' -
4"
41' - 4"
57
' -
8"
75' - 0"
57
' - 1
1"
7' -
2 1
/2"
65
' -
1 1
/2"
95' - 3"
28' - 1 7/8" 16' - 7 3/8" 10' - 10 5/8" 16' - 7 3/8" 22' - 11 3/4"
213' - 7"
60
' -
0 1
/8"
12
3' -
9 1
/16
"
EXISTING GAS HEATER FLUE & BOILER FLUE -SEE DETAIL 3/A-201
ICE DAM MEMBRANE
ICE DAM MEMBRANE
DOWNSPOUT (15' TO GRADE)
EXISTING ROOF VENTILATOR
EXISTING GAS HEATER FLUE & BOILER FLUE, TYP. EACH UNIT - SEE DETAIL 3/A-201.
CONTINUOUS METAL GUTTER
ICE DAM MEMBRANE
DOWNSPOUT (9' TO GRADE)
DOWNSPOUT (20' TO GRADE)
EXISTING 2'-6" X 3'-0" ROOF HATCH -PROVIDE ROOF CRICKET BETWEEN ROOF HATCH AND EXTERIOR WALL OF MULTIPURPOSE BUILDING - SEE DETAIL 7/A-200
EXISTING RTU FOR KITCHEN HOOD INTAKE AND EXHAUST SEE 6/A-200
PROVIDE ROOF CRICKET
ICE & WATER SHEILD MEMBRANE AT FASCIA, VALLEYS AND CURBS
PROVIDE NEW PREFINISHED ALUMINUM ATTIC VENTS IN EXISTING OPENINGS (MATCH EXISTING SIZE)
ICE DAM MEMBRANE LAYER INTO PVC ROOFING
PROVIDE CRICKETS AT EXISTING SKYLIGHTS
PROVIDE TAPERED ROOF INSUL TO ALLOW POSITIVE DRAINAGE TO ROOF DRAINS.
NEW 4" RETROFIT ROOF DRAIN AND OVERFLOW DRAIN SEE 7/A-201
HIP
TYP. RAKE
RIDGE
ASPHALT SHINGLES
LINE OF ROOF SLOPE CHANGE - SEE 6/A-201
RA
KE RIDGE
ASPHALT SHINGLES
REPLACE EXISTING CONT. 2" EXPANSION JOINT COVER AND FLASHING ALONG MULTIPURPOSE ROOM CMU WALL. SEE 2/A-200
RA
KE
RIDGE
ASPHALT SHINGLES
VALL
EYVALLEY
HVAC UNIT AND CURB
VA
LLE
Y
HIP
HIP
VERT. FACE SEE 3/A-200
RIDGE
RID
GE
RID
GE
VA
LLE
YVA
LLE
Y
VA
LLE
Y
VA
LLE
Y
SLOPE DOWNSLOPE DOWN
SLOPE DOWN
NEW SCUPPER WITH 12" X 12" X 12" CONDUCTOR HEAD AND PREFIN ALUMINUM DOWNSPOUT 13' TO GRADE
RID
GE
D.S
D.S.D.S.D.S.D.S.D.S.
D.S. D.S. D.S.
RIDGE RIDGE
RID
GE
D.S.
D.S.
D.S.D.S.
D.S.
D.S.
D.S.
HIP
RID
GE
VA
LLE
Y
MAINTENANCE BUILDING
5"
/ 12
"
5"
/ 12
"
5" / 12"5" / 12"
DOWNSPOUT TYP. @ 9 LOCATIONS (9' TO GRADE)
NEW CONTINOUS PREFINISHED ALUMINUM GUTTERS AND DOWNSPOUT SYSTEM
DOWNSPOUT (9' TO GRADE)
DOWNSPOUT (9' TO GRADE)
DOWNSPOUT TYP. @ 7 LOCATIONS (9' TO GRADE)
5"
/ 12
"5
" /
12
"
5" / 12"5" / 12"
5"
/ 12
"5
" /
12
"
5" / 12" 5" / 12"
5"
/ 12
"5
" /
12
"
5" / 12"5" / 12"
5" / 12"5" / 12"
5"
/ 12
"5
" /
12
"
5"
/ 12
"5
" /
12
"
DOWNSPOUT TYP. @ 3 LOCATIONS (12' TO GRADE)
9" / 12" 9" / 12" 9" / 12"9" / 12"
NEW METAL PRE-FINISHED PARAPET CAP
DOWNSPOUT TYP. @7 LOCATIONS (9' TO GRADE)
DOWNSPOUT(15' TO ROOF LEVEL BELOW)
DOWNSPOUT(15' TO ROOF LEVEL BELOW)
DOWNSPOUT (20' TO GRADE)
5" / 12" 5" / 12"
SLOPE DOWN 5" / 12"
DOWNSPOUT (15' TO GRADE) CONNECT TO EXISTING BELOW GRADE SYSTEM
DOWNSPOUT (9' TO GRADE)
DOWNSPOUT (9' TO GRADE)
DOWNSPOUT (15' TO GRADE)
TYP.
5"
/ 12
"5
" /
12
"
106
102
102
102
103
TYP.
103
103103
103
103
TYP.
TYP.TYP.
TYP.
TYP.
103
TYP.
106 106
106
106
106
106
4
A-201
4
A-201
4
A-2014
A-201
4
A-201
4
A-201
6
A-201
6
A-201
6
A-201
PROVIDE ROOF CRICKET
EXISTING GAS HEATER FLUE & BOILER FLUE -SEE DETAIL 3/A-201
EXISTING GAS HEATER FLUE & BOILER FLUE -SEE DETAIL 3/A-201
EXISTING EXHAUST FAN FLUE
EXISTING EXHAUST FAN FLUE
EXISTING GAS HEATER FLUE & BOILER FLUE -SEE DETAIL 6/A-200.
EXISTING EXHAUST FAN FLUE
EXISTING EXHAUST FAN FLUE
EXISTING GAS HEATER FLUE & BOILER FLUE -SEE DETAIL 3/A-201
5" / 12"
106
6
A-201
103
103TYP.
RTU CURB. SEE 6/A-200
REMOVE EXISTING CAPPED FLUE BELOW ROOF DECK. PATCH DECKING AS REQUIRED
PROVIDE CRICKET AT EXISTING FLUE
PROVIDE CRICKET AT EXISTING FLUE
105105
105105
105105
EXISTING MINI-SPLIT HVAC UNIT ON NEW PVC ROOFING
EXISTING CONDENSING UNIT ON NEW PRESSURE TREATED 4x4 BLOCKING OVER PVC ROOFING
6
A-201
D.S.
D.S.
D.S.
D.S.
D.S.
D.S.D.S.
D.S.
D.S. D.S.
D.S.
D.S.
D.S.
D.S.
D.S.
D.S. D.S.
D.S.
D.S.
D.S.
D.S.
D.S.
D.S. D.S.
D.S.
D.S.
D.S.
D.S.
INSTALL NEW PVC MEMBRANE ON PARAPET WALL AND RE-ATTACH DISCONNECT PANEL MOUNTING BRACKETS TO PARAPET WALL
D.S.
D.S.
REPLACE EXISTING METAL WATER HEATER EXHAUST VENT PIPE WITH PVC PIPE
SHINGLE OVER RIDGE VENT
1. CONTRACTOR SHALL FIELD VERIFY DIMENSIONS AND BE RESPONSIBLE FOR THE SAME. ANY DISCREPENCIESSHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION PRIOR TO FABRICATION AND/OR INSTALLATION.
2. CONTRACTOR TO VERIFY ALL ROOF PENETRATION LOCATIONS.3. NOT USED4. FOR ROOF DETAILS SEE SHEET A-201 & A-2025. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE STATE OF MISSOURI AND ALL OTHER
APPLICABLE LOCAL CODES, ORDINANCES AND STANDARDS.6. CONTRACTOR SHALL USE EXTREME CARE AND PRECAUTION DURING CONSTRUCTION SO AS NOT TO DAMAGE
EXISTING ADJACENT FACILITIES. ANY DAMAGE DONE TO EXISTING FACILITIES DURING CONSTRUCTION SHALLBE REPAIRED TO THE SATISFACTION OF THE ARCHITECT WITHOUT ADDITIONAL COST TO THE OWNER.
7. ALL DIMENSIONS ARE NOMINAL AND ARE TO FINISH TO FINISH OR FACE TO FACE OF CONSTRUCTION UNLESSOTHERWISE NOTED.
8. CONTRACTOR TO REMOVE ALL TRASH AND DEBRIS FROM SITE ON A DAILY BASIS. COORDINATE DUMPSTERLOCATION AND ACCESS WITH OWNER.
9. OWNER WILL BE CONTINUALLY OCCUPYING THE BUILDING AND THE AREAS BELOW THE CONSTRUCTION. POINTOF CONTACT AT THE SITE TO BE PROVIDED AT PRE-CONSTRUCTION MEETING. NOTIFICATION MUST BE GIVEN(72) HOURS IN ADVANCE FOR ANY WORK WHICH WILL AFFECT THEIR NORMAL WORKING OPERATIONS.
10. SHOULD ANY DOUBT OR QUESTION ARISE WITH RESPECT TO THE TRUE MEANING OF THE DRAWINGS ORSPECIFICATIONS, REFERENCE SHALL BE MADE TO THE ARCHITECT WHOSE DECISION THERIN SHALL BE FINALAND CONCLUSIVE. NO ALLEGED ORAL ADMISSION, CONDONATION, OR INADVERTENT NEGLECT ON PART OFTHE ARCHITECT WILL BE ACCEPTED AS AN EXCUSE FOR INFERIOR WORK.
11. CONTRACTOR IS RESPONSIBLE FOR TEMPORARY DIRECTIONAL SIGNAGE AS WELL AS FRIENDLYCONSTRUCTION SIGNAGE NOTIFYING BUILDING OCCUPANTS AS WELL AS THE PUBLIC.
12. CONTRACTOR SHALL NOT ENGAGE IN ANY ACTIVITY WHICH MAY ENDANGER THE BUILDING OCCUPANTS ASWELL AS THE PUBLIC.
13. CONTRACTOR AND ALL SUBCONTRACTORS ARE REQUIRED TO REVIEW CONTRACT DOCUMENTS OF VARIOUSDISCIPLES AND FAMILIARIZE THEMSELVES WITH THE EXTENT OF WORK SHOWN ON THE DRAWINGS.
14. CONTRACTOR AND ALL SUBCONTRACTORS ARE ENCOURAGED TO READ AND UNDERSTAND THE PROJECTMANUAL PRIOR TO BIDDING OR START OF ANY CONSTRUCTION.
15. CONTRACTOR IS RESPONSIBLE FOR WATER TIGHTENING THE ROOF AND AREAS UNDER CONSTRUCTION ATTHE END OF EACH DAY REGARDLESS OF THE WEATHER FORCAST.
16. CONTRACTOR SHALL NOT IN ANY WAY STORE MATERIALS, EQUIPMENT, OR ANY ITEMS ON THE ROOF WHICHWILL INQUIRE ADDITIONAL LOAD ON EXISTING STRUCTURAL MEMBERS.
17. PROVIDE ADEQUATE SLOPE IN GUTTERS TO DOWNSPOUTS TO AVOID ANY STANDING WATER IN GUTTERS.18. ENTIRE EXISTING FLAT DECK SHALL BE EXAMINED FOR STRUCTURAL SOUNDNESS. DO NOT INSTALL ANY ROOF
FRAMING OVER UNSTABLE DECKING. ALL NEW ROOF ATTACHMENT SHALL BE ON SOLID SUBSTRATE.19. CONTRACTOR SHALL VERIFY THAT THE CONDITION OF THE EXISTING ROOF SURFACE WILL ALLOW FOR
SOUND INSTALLATION OF THE NEW PVC AND TAPERED INSULATION SYSTEM AS DESIGNED BY THE MFG.20. UNLESS OTHERWISE NOTED, G.C. SHALL PATCH AND REPAIR ALL ADJACENT SURFACES BY NEW
CONSTRUCTION OR DEMOLITION.
SHEET NUMBER:
3636 South Geyer Road Suite 100St. Louis, MO 63127314.436.0865FAX: 314.471.0664
ARCHITECTURE ENGINEERING GEOSPATIAL
STATE OF MISSOURIMICHAEL L. PARSON,GOVENOR
PROFESSIONAL SEAL
OFFICE OF ADMINISTRATION DIVISION OF FACILITIES MANAGEMENT,DESIGN AND CONSTRUCTION
DEPARTMENT OF PUBLIC SAFETY, OFFICE OF THE ADJUTANT GENERAL MISSOURI NATION GUARD
2 OF 6 SHEETS
00/00/0000
SHEET TITLE:
DESIGNED BY:
DRAWN BY:
CAD DWG FILE:
CHECKED BY:
REVISION:
DATE:
REVISION:
ISSUE DATE:
REVISION:DATE:
DATE:
SITE #
PROJECT #
ASSET #
REPLACE ROOFS, MULTIPLE BUILDINGS MONTGOMERY CITY YOUTH CENTER DIVISION OF YOUTH SERVICES
H1908-01
7709
(8877709007), (8877709008)(8877709009), (8877709010)(8877709011), (8877709012)(8877709013)
BID DOCUMENTS 06 NOVEMBER 2019
A-100
OVERALL ROOF PLAN
SCALE : 1/16" = 1'-0"A1 OVERALL ROOF PLANS
PLAN NORTH
102 NEW 60 MIL PVC ADHERED/HEATWELDED ROOFING SYSTEM OVER 1/2"ISOGUARD HD COVER BOARD OVERNEW 4 1/2" POLYISO BOARDINSULATION ONTO EXISTING WOODDECK FOR A TOTAL ROOF SYSTEMVALUE OF R-30.
103 NEW PREFINISHED ALUMINUMGUTTERS AND DOWNSPOUTS TOMATCH EXISTING.
105 PROVIDE ICE AND WATER SHEILDMEMBRANE ON AND AROUND EXISTINGSKYLIGHT CURBS UNDER ALUMINUMAPRON FLASHING. (TYP. ALLSKYLIGHTS) SEE DETAIL 5/A-201
106 NEW ASPHALT SHINGLE, OVER NEW #30FELT AND ICE DAM, OVER EXISTINGPLYWOOD ROOF SHEATHING
REFERENCE KEYNOTES:
GENERAL NOTES:
4 OF 6 SHEETS
06 NOVEMBER 2019
21. SEE SECTION 012200 – UNIT PRICES FOR BASED QUANTITY AND UNIT PRICE FOR REPLACING DAMAGED PLYWOOD ROOF SHEATHING.
P.T. WOOD NAILERS
3" MIN. 3" MIN.
INTERPLY REQUIRED FOR 15 & 20 YR SYSTEMS
BASE AND INTERPLY SHEETS AS REQ'D
RECOVERY BOARD
4 1/2" POLYISO INSULATION
INSULATED ROOF HATCH
HIGH-DOMED, CAPPED, GASKETED FASTENERS AS REQ'D - UNDER HATCH CURB COUNTER FLASHING
FASTEN APPROX. 8" o.c.
EXISTING ROOF HATCH INTEGRAL COUNTER FLASHING
EXISTING INSULATED ROOF HATCH CURB, PAINTED EXPOSED SURFACES
1' -
0"
7"
SEAL EDGES OF FLASHING MEMBRANE W/ LAP EDGE SEALANT, TYP.
4" CANT, TYP.
3" MIN.3" MIN. EXISTING WOOD ROOF DECK TO REMAIN
NEW 1/2" COVERBOARD OVER 4 1/2" MIN. RIGID INSULATION (TYP)
NEW 2x4 NAILERS. SCREW TO DECKING
EXISTING BATT INSULATION TO REMAIN
EXISTING 1/2" PLYWOOD TO REMAIN
PVC FLASHING AND LAP SPLICE
EXISTING WOOD TRUSS JOIST TO REMAIN
EXISTING MASONRY WALL TO REMAIN AS IS
NEW .032 BRONZE ALUM.
EXIST. 2x4. LEAVE IN PLACE AND RE-ANCHOR
NEW 6" PREFINISHED ALUMINUM GUTTER & DOWNSPOUT SYSTEM SHAPE TO MATCH EXISTING ROOF GUTTERS.
NOTES:1. DECK FLANGE MUST BE TOTALLY
COVERED BY PVC ELASTOFORM FLASHING
2. MIN 2" LAP SPLICE FROM NAIL HEAD
3. TPO ELASTOFORM FLASHING MUST OVERLAP DECK MEMBRANE MIN 3"
4. FASTENERS AND FASTENER PATTERN AS RECOMMENDED BY METAL EDGE MANUFACTURER
5. TREATED WOOD NAILER MUST EXTEND PAST TOTAL WIDTH OF METAL EDGE DECK FLANGE
KEEP MASTIC, MEMBRANE AND LAP SEALANT BELOW EXISTING WEEPS
LAP SEALANT
WATER CUT-OFF MASTIC
TERMINATION BAR NAIL-IN
TERMINATION BAR
BONDING ADHESIVE
PVC MEMBRANE
LAP SEALANT
PRE-MOLDED PIPE SEAL
STAINLESS STEEL CLAMPING RING
PVC FLASHING OVER PVC BONDING ADHESIVE
WATER CUT-OFF MASTIC
4" MIN INSULATION
IN-SEAM SEALANT
SPLICING CEMENT
LAP SEALANT
NOTES:
1. REMOVE ALL OTHER FLASHING
2. PRE-MOLDED PIPE SEAL MUST HAVE INTACT RIB AT TOP EDGE, REGARDLESS OF PIPE DIAMETER.
3. APPLY IN-SEAM SEALANT 1/2" FROM INSIDE EDGE OF PIPE SEAL FLANGE.
4. DECK FLANGES OF THE PRE-MOLDED PIPE FLASHING SHALL NOT BE OVERLAPPED, CUT OR APPLIED OVER ANY ANGLE CHANGE.
PVC MEMBRANE
APPROX. 1/2"
PVC BONDING ADHESIVE
SEE TERMINATION BAR DETAIL 4-A/200
PVC MEMBRANE
1/8
" M
IN.
1"
MA
X.
3" MIN.
6" WIDE
FULLY ADHERED AND HEAT WELDED PVC MEMBRANE OVER 1/2" COVER BOARD OVER 4 1/2" RIGID INSULATION
SPLICING CEMENT
4 1/2" RIGID INSULATION
SEAM FASTENING PLATE AND FASTENER (MAX. 12" O.C.)
LAP SEALANT
3" MIN.
3" MIN.
3" MIN.
NEW SHINGLE ROOF
NEW METAL RIDGE CAP
REMOVE EXISTING EPDM AND PROVIDE NEW PVC MEMBRANE OVER EXISTING PLYWOOD SHEATHING
3 1
/8"
REMOVE 4 SCREWS HOLDING MOUNTING BRACKETS OF DISCONNECT PANEL TO PARAPET WALL FOR REMOVAL OF EXISTING EPDM AND INSTALL OF NEW PVC MEMBRANE
8'-0
" (F
IEL
D V
ER
IFY
)
PVC MEMBRANE OVER 1/2" COVERBOARD
LAP SEALANT
SPLICING CEMENT
4 1/2" RIGID INSULATION
PVC MEMBRANE
IN-SEAM SEALANT
SEAM FASTENING PLATE (MAX. 12" O.C.)
BONDING ADHESIVE
EXISTING METAL FLASHING
EXISTING ROOF CURB
3" MIN.
NOTES:
1. FASTEN MEMBRANE FLASHING 12" O.C. IF FASTENER PENETRATES METAL COUNTERFLASHING, USE PVC WASHER OR APPLY WATER CUT-OFF MASTIC OR CAULK FASTENER HEAD.
2. 6" WIDE UNCURED ELASTOFOAM FLASHING OR PRESSURE SENSITIVE FLASHING MUST BE CENTERED OVER FIELD SPLICE AT ANGLE CHANGE.
3. THIS DETAIL USED FOR POWER VENTILATORS
4. EXISTING CURB HEIGHT EXTENDED USING 20 GA. SHEET METAL FOR 2 MECHANICAL UNITS ON NORTH EAST CORNER AND SOUTH END OF LOW ROOF CHANGE.
EXISTING 1" WOOD SHEATHING
EXISTIND WOOD TRUSSES
PVC MEMBRANE OVER 1/2" COVERBOARD
LAP SEALANT
MEMBRANE FASTENER
4 1/2" RIGID INSULATION
PVC MEMBRANE
BONDING ADHESIVE
EXISTING WALL
FOAM TUBE TO MATCH THE WIDTH OF EXPANSION JOINT
SHEET NUMBER:
3636 South Geyer Road Suite 100St. Louis, MO 63127314.436.0865FAX: 314.471.0664
ARCHITECTURE ENGINEERING GEOSPATIAL
STATE OF MISSOURIMICHAEL L. PARSON,GOVENOR
PROFESSIONAL SEAL
OFFICE OF ADMINISTRATION DIVISION OF FACILITIES MANAGEMENT,DESIGN AND CONSTRUCTION
DEPARTMENT OF PUBLIC SAFETY, OFFICE OF THE ADJUTANT GENERAL MISSOURI NATION GUARD
2 OF 6 SHEETS
00/00/0000
SHEET TITLE:
DESIGNED BY:
DRAWN BY:
CAD DWG FILE:
CHECKED BY:
REVISION:
DATE:
REVISION:
ISSUE DATE:
REVISION:DATE:
DATE:
SITE #
PROJECT #
ASSET #
REPLACE ROOFS, MULTIPLE BUILDINGS MONTGOMERY CITY YOUTH CENTER DIVISION OF YOUTH SERVICES
H1908-01
7709
(8877709007), (8877709008)(8877709009), (8877709010)(8877709011), (8877709012)(8877709013)
BID DOCUMENTS 06 NOVEMBER 2019
A-200
ROOF DETAILS
SCALE : 6" = 1'-0"7 ROOF HATCH CURB DETAIL
SCALE : 1 1/2" = 1'-0"1 WALL SECTION
SCALE : 1 1/2" = 1'-0"4 TERMINATION DETAIL
SCALE : 1 1/2" = 1'-0"5 VENT PIPE FLASHING DETAIL
SCALE : 1 1/2" = 1'-0"3 WALL/ROOF TRANSITION
SCALE : 3" = 1'-0"6 CURB DETAIL (TYP)
SCALE : 3" = 1'-0"2 EXPANSION JOINT @ WALL OR PARAPET
5 OF 6 SHEETS
06 NOVEMBER 2019
WALL CONSTRUCTION
PRE-FINISHEDALUM. DOWNSPOUT
COMPATIBLE SEALANT
METAL SLEEVE
MASONRY ANCHOR SET IN SEALANT
BRACING STRAP -COLOR AND MATERIAL TO MATCH DOWNSPOUT
SLOPE
ENDS
GUTTER SHALL LAP
PRE-FIN. ALUM. EAVE FLASHING
NOTE:1. PROVIDE EXPANSION JOINT SPACING @ GUTTER PER SMACNA GUIDELINES.
2. EXACT DETAILS & INSTALLATION PER MFR. RECOMMENDATIONS.
PRE-FIN. ALUM. GUTTER
NOTE:1. PRE-MOLDED PIPE FLASHING MAY BE CUT TO HEIGHT, BUT NO LOWER THAN REINFORCING RING (NO WRINKLES OR FOLDS UNDER CLAMPING RING).
RO
UN
D P
EN
ET
RA
TIO
N
CONTINUOUS BEAD OF AP SEALANT OR HIGHER GRADE URETHANE SEALANT
STAINLESS STEEL CLAMPING RING
PRE-MOLDED PIPE FLASHING SET IN FLASHING CEMENT
FIELD FABRICATED GALVANIZED METAL HOOD INSTALL TARGET
MEMBRANE TO EXTEND A MIN. OF 1/2" UP PIPE
NEW ASPHALT SHINGLED RIDGE VENT (ONLY AT MAINTENANCE BUILDING)
ASPHALT SHINGLES ON #30 FELT OVER PLYWOOD ROOF SHEATHING
EXISTING PRE-FINISHED METAL FASCIA TO REMAIN
NEW PRE-FINISHED METAL DOWNSPOUT AND GUTTER
NEW PRE-FINISHED METAL ROOF DRIP EDGE FLASHING
NEW ICE/WATER SHEILD MEMBRANE UP ROOF TO 3'-0"PAST INSIDE FACE OF EXTERIOR WALL.
NEW ASPHALT SHINGLES ON #30 FLETOVER PLYWOOD ROOF SHEATHING
OVERLAP
18" MIN.
CONTINUE UNDERLAYMENT OVER EVERGUARD MEMBRANE FLASHING
APPROVED FASTENERS
EVERGUARD WATER BLOCK
EVERGUARD BONDING ADHESIVE (OPTIONAL)
HEAT-WELDED LAP
DRILL-TEC PLATES & SCREWS 12" (305 MM) O.C.
2" TALL DAM (ONLY AT OVERFLOW DRAIN)
DECK CLAMP
NEW METAL STRAINER BASKET AND PVC RETROFIT ROOF DRAIN KIT
COMPRESSION RING
CONTINUOUS SEALANT BETWEEN DRAIN BOWL FLANGE AND MEMBRANE
PVC MEMBRANE OVER 1/2" COVERBOARD - RUN 1/2" MIN. INTO BOWL PAST CLAMPING RING
TAPER INSULATION TO DRAIN - SEE MANUFACTURER'S REQUIREMENTS FOR MAX SLOPE
EXISTING METAL DECK TO REMAIN
EXISTING 4 1/2" RIGID INSULATION
RUBBER EXPANSION COUPLING
ASPHALT SHINGLES ON #30 FELT OVER EXISTING PLYWOOD ROOF SHEATHING
EXISTING CURB AND SKYLIGHT
WATER AND ICE SHIELD MEMBRANE
PRE-FINISHED ALUMINUM APRON FLASHING
SHEET NUMBER:
3636 South Geyer Road Suite 100St. Louis, MO 63127314.436.0865FAX: 314.471.0664
ARCHITECTURE ENGINEERING GEOSPATIAL
STATE OF MISSOURIMICHAEL L. PARSON,GOVENOR
PROFESSIONAL SEAL
OFFICE OF ADMINISTRATION DIVISION OF FACILITIES MANAGEMENT,DESIGN AND CONSTRUCTION
DEPARTMENT OF PUBLIC SAFETY, OFFICE OF THE ADJUTANT GENERAL MISSOURI NATION GUARD
2 OF 6 SHEETS
00/00/0000
SHEET TITLE:
DESIGNED BY:
DRAWN BY:
CAD DWG FILE:
CHECKED BY:
REVISION:
DATE:
REVISION:
ISSUE DATE:
REVISION:DATE:
DATE:
SITE #
PROJECT #
ASSET #
REPLACE ROOFS, MULTIPLE BUILDINGS MONTGOMERY CITY YOUTH CENTER DIVISION OF YOUTH SERVICES
H1908-01
7709
(8877709007), (8877709008)(8877709009), (8877709010)(8877709011), (8877709012)(8877709013)
BID DOCUMENTS 06 NOVEMBER 2019
A-201
ROOF DETAILS
SCALE : 1 1/2" = 1'-0"1 DOWNSPOUT BRACING
SCALE : 1 1/2" = 1'-0"2 GUTTER EXPANSION
SCALE : 1 1/2" = 1'-0"3 TYP. PIPE PENETRATION
SCALE : 1 1/2" = 1'-0"6 TYP. RIDGE VENT
SCALE : 1 1/2" = 1'-0"4 ROOF EAVE DETAIL
SCALE : 3" = 1'-0"7 SHINGLE TO PVC DETAILSCALE : 3" = 1'-0"8 NEW RETROFIT DRAIN & OVERFLOW ASSEMBLY DETAIL
SCALE : 3" = 1'-0"5 SKYLIGHT DETAIL
BONDING ADHESIVE
WATER BLOCK
ASPHALT SHINGLES OVER ICE & WATERSHIELD. CONTINUE ICE & WATER SHIELDUNDERLAYMENT OVER PVC MEMBRANE
HIGH TEMP BOOTREQUIRED ATCONCENTRIC VENTS(1 PER UNIT)
5 OF 6 SHEETS
06 NOVEMBER 2019
6 OF 6 SHEETS