rental with stage iiia engines - visa rent · rental with stage iiia engines range english ... visa...
TRANSCRIPT
100% MADE IN ITALY
General Catalogue
GENERATOR SETS WITH STAGE IIIA ENGINES RENTAL
RANGE
ENGLISH VERSION
WWW.VISA.IT
VISA SPA RENTAL SERVICE
Visa SpA offers mobile generator sets designed for rental industry, counting on a fleet of 300 sound-attenuated generators, of recent production, ranging from 20.0 to 2000.0 kVA. Different versions and configurations are available to cover different applications and needs. Gensets can be paralleled to reach up to 30 MW. All the machines are equipped with safety features that comply with the current regulations.Beside the standard versions, Visa SpA provides generators with variable frequency from 50Hz to 60 Hz and/or multiple voltages; the gensets are equipped with automatic control panels, parallel configuration support, twin-pack paralleling gensets and gensets with particulate filter. On request, super silent versions are also available, 50 dbA at 7 mt.Onis Visa gensets high quality is guaranteed by different official certifications: since 1997 Visa SpA is certified ISO 9000 – Quality Management System - and since 2002, it is certified ISO 14001 – Environmental Management System. In 2009 it was inspected again by official agencies, acquiring the upgrade certification to ISO 9001-2008 and ISO 14001-2004.
CUTTING-EDGE TECHNOLOGIES AND EQUIPMENTWith over 55 years of experience in the field of power generation and rental services, Visa SpA has developed a relevant position as international player, representing one of the finest expression of Italian technology and innovation in the energy sector. Particularly in these recent years, it has invested a great deal of resources and technological know-how to improve its ranges of products even better, by providing the machines with certain value-added features, it means electronic devices to grant the highest efficiency and reliability, as well as safety features for safe operating in every sectors.Particular attention is always paid to training courses for technicians and dealers, to keep them updated about new solutions and strategies. Visa SpA has very modern training rooms directly connected to the testing rooms so that all trainees can run tests and simulations safely.
TURN-KEY SOLUTION: A CONVENIENT CHOICE- Reduce fixed costs: no capital expenditure or physical space is required.- Improve management during peak sales periods.- Take advantage of fiscal and financial benefits (tax deductions).- Select the most suitable machine for the specific application.- Eliminate technological obsolescence of one’s fleet.- Use the rental equipment only for the time period necessary to complete the task.- Expertise: highly qualified technical staff specialised in designing and developing specific projects or applications, providing efficient, integrated solutions for just about every needs.- Transportation: Visa SpA can arrange the transport of the electricity generators , wherever you are, through the use of specific handling equipment, including cranes if necessary.- Installation and commissioning.- Full technical support and after-sale services are constantly provided by highly skilled technical team, operating 24/7.- Plant management.- Global insurance coverage.
SOUNDPROOF GENERATING SETSMODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHT
MODELREF
POWERSIZE
kVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
P105SS C20SS 100,00 80,00 87/490 N/A 11,2 17,1 22,6 2950 1020 1740 1600
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
P155SS C30SS 150,00 120,00 230/760 N/A 20,0 31,0 41,0 3390 1020 2100 2400
P180SS C30SS 180,00 144,00 230/760 N/A 20,5 31,0 40,2 3390 1020 2100 2450
JD180SS C30SS 180,00 144,00 230/760 10,7 20,5 31,3 40,8 3390 1020 1910 2270
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
P101GX GV100 100,00 80,00 120/365 N/A 11,2 17,1 22,6 3060 1205 2170 1760
JD180GX GV100 180,00 144,00 120/365 10,7 20,5 31,3 40,8 3230 1205 2170 2190
JD250GX GV100 250,00 200,00 120/365 14,94 28,0 40,6 54,24 3230 1205 2170 2750
V250GX GV100 250,00 200,00 120/365 18,8 32,8 44,3 54,5 3230 1205 2170 2980
* The listed weight refers to a standard genset, with an empty fuel tank and no accessories. Different size fuel tanks and any optional or additional equipment/accessories may modify the weight, dimensions andperformance.
SOUNDPROOF GENERATING SETSMODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHT
MODELREF
POWERSIZE
kVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
P105SS C20SS 100,00 80,00 87/490 N/A 11,2 17,1 22,6 2950 1020 1740 1600
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
P155SS C30SS 150,00 120,00 230/760 N/A 20,0 31,0 41,0 3390 1020 2100 2400
P180SS C30SS 180,00 144,00 230/760 N/A 20,5 31,0 40,2 3390 1020 2100 2450
JD180SS C30SS 180,00 144,00 230/760 10,7 20,5 31,3 40,8 3390 1020 1910 2270
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
P101GX GV100 100,00 80,00 120/365 N/A 11,2 17,1 22,6 3060 1205 2170 1760
JD180GX GV100 180,00 144,00 120/365 10,7 20,5 31,3 40,8 3230 1205 2170 2190
JD250GX GV100 250,00 200,00 120/365 14,94 28,0 40,6 54,24 3230 1205 2170 2750
V250GX GV100 250,00 200,00 120/365 18,8 32,8 44,3 54,5 3230 1205 2170 2980
* The listed weight refers to a standard genset, with an empty fuel tank and no accessories. Different size fuel tanks and any optional or additional equipment/accessories may modify the weight, dimensions andperformance.
SOUNDPROOF GENERATING SETSMODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHT
MODELREF
POWERSIZE
kVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
V326GX GV150 326,00 260,80 120/400 20,0 36,1 52,0 70,1 4000 1300 2400 3680
V385GX GV150 375,00 300,00 120/400 20,76 38,26 56,24 76,14 4000 1300 2400 4700
JD400GX GV150 388,00 310,40 120/400 22,2 40,4 59,4 81,0 4000 1300 2400 4390
P400GX GV150 400,00 320,00 120/400 N/A 46 65 85 4000 1300 2564 4760
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
JD250SS C40SS 250,00 200,00 270/880 14,94 28,0 40,6 54,24 4065 1320 2550 3385
JD251SS C40SS 255,00 204,00 270 14,94 28,0 40,6 54,24 4065 1320 2550 3500
JD400SS C40SS 400,00 320,00 430/880 22,2 40,4 59,4 81,0 4080 1320 2600 4450
P405SS C40SS 400,00 320,00 430/880 N/A 42,0 61,0 81,0 4065 1320 2595 4900
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
P600GX GV200 600,00 480,00 120/950 N/A 63,0 96,0 129,0 4500 1840 2540 5970
V630GX GV200 630,00 504,00 120/950 34,5 62,9 94,3 128,0 4500 1840 2540 6970
* The listed weight refers to a standard genset, with an empty fuel tank and no accessories. Different size fuel tanks and any optional or additional equipment/accessories may modify the weight, dimensions andperformance.
SOUNDPROOF GENERATING SETSMODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHT
MODELREF
POWERSIZE
kVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
P21 FOX 20,00 16,00 50 N/A 2,9 4,0 5,3 1660 770 1350 690
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
D41GX GV020 40,00 32,00 50/120 3,7 5,3 7,4 9,9 2030 970 1560 1230
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
P60GX Ecotop 60,00 48,00 280 4,1 7,2 10,4 13,9 2385 1100 2254 1750
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
JD61GX GV060 60,00 48,00 70/160 4,6 7,5 10,8 14,1 2560 1040 1805 1510
* The listed weight refers to a standard genset, with an empty fuel tank and no accessories. Different size fuel tanks and any optional or additional equipment/accessories may modify the weight, dimensions andperformance.
SOUNDPROOF GENERATING SETSMODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHT
MODELREF
POWERSIZE
kVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
P635SS C50SS 635,00 508,00 620 N/A 63,0 92,0 125 5105 1800 2785 6577
P650SS C50SS 650,00 520,00 730 N/A 66,0 97,0 132,0 5105 1840 2785 6500
P500SS C50SS 500,00 400,00 730 N/A 55,0 81,0 106,0 5105 1840 2785 6100
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
MT780S C60S 780,00 624,00 400 45,2 82,6 120,0 159,0 5670 2200 2920 9100
MT800S C60S 800,00 640,00 400 45,2 82,6 120,0 159,0 5670 2200 2920 9100
P805S C60S 800,00 640,00 400 N/A 90,0 130,0 172,0 5700 2200 2950 8750
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
MT1130S C60S 1130,00 904,00 400 63,0 116,0 171,0 230,0 8600 2200 3350 12200
P1260S C60S 1253,00 1002,40 400 N/A 141,0 196,0 258,0 8600 2200 3400 14100
P1500S C60S 1505,00 1204,00 400 N/A 160,0 230,0 300,0 8600 2200 3400 14300
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
M1900S CONT.HC 1900,00 1520,00 1500/2000 125,0 220,0 305,0 396,0 12190 2438 2896 25000
* The listed weight refers to a standard genset, with an empty fuel tank and no accessories. Different size fuel tanks and any optional or additional equipment/accessories may modify the weight, dimensions andperformance.
SOUNDPROOF GENERATING SETSMODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHT
MODELREF
POWERSIZE
kVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
P21 FOX 20,00 16,00 50 N/A 2,9 4,0 5,3 1660 770 1350 690
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
D41GX GV020 40,00 32,00 50/120 3,7 5,3 7,4 9,9 2030 970 1560 1230
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
P60GX Ecotop 60,00 48,00 280 4,1 7,2 10,4 13,9 2385 1100 2254 1750
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
JD61GX GV060 60,00 48,00 70/160 4,6 7,5 10,8 14,1 2560 1040 1805 1510
* The listed weight refers to a standard genset, with an empty fuel tank and no accessories. Different size fuel tanks and any optional or additional equipment/accessories may modify the weight, dimensions andperformance.
SOUNDPROOF GENERATING SETSMODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHT
MODELREF
POWERSIZE
kVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
P635SS C50SS 635,00 508,00 620 N/A 63,0 92,0 125 5105 1800 2785 6577
P650SS C50SS 650,00 520,00 730 N/A 66,0 97,0 132,0 5105 1840 2785 6500
P500SS C50SS 500,00 400,00 730 N/A 55,0 81,0 106,0 5105 1840 2785 6100
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
MT780S C60S 780,00 624,00 400 45,2 82,6 120,0 159,0 5670 2200 2920 9100
MT800S C60S 800,00 640,00 400 45,2 82,6 120,0 159,0 5670 2200 2920 9100
P805S C60S 800,00 640,00 400 N/A 90,0 130,0 172,0 5700 2200 2950 8750
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
MT1130S C60S 1130,00 904,00 400 63,0 116,0 171,0 230,0 8600 2200 3350 12200
P1260S C60S 1253,00 1002,40 400 N/A 141,0 196,0 258,0 8600 2200 3400 14100
P1500S C60S 1505,00 1204,00 400 N/A 160,0 230,0 300,0 8600 2200 3400 14300
MODEL POWER FUEL TANK/FUEL CONSUMPTION SIZE/WEIGHTMODEL
REFPOWER
SIZEkVA kW litres l./h 25% l./h 50% l./h 75% l./h 100% L mm W mm H mm kg*
M1900S CONT.HC 1900,00 1520,00 1500/2000 125,0 220,0 305,0 396,0 12190 2438 2896 25000
* The listed weight refers to a standard genset, with an empty fuel tank and no accessories. Different size fuel tanks and any optional or additional equipment/accessories may modify the weight, dimensions andperformance.
CISTERNS IN CONTAINERSAREAS OF APPLICATION: External container tanks are used where a greater operating autonomy of power generation is needed, offering better protection againstatmospheric agents. Their sturdy structure allows them to operate effectively in difficult conditions (construction sites, isolated areas, etc.) and provides more efficientsafety measures to prevent theft and tampering, making them easy to transport and commission. They are available in different fuel capacities, from 920 to 12,000litres, according to the specific requirements, are built onboard ISO standard containers, and are equipped with a liquid retention basin.
MODEL CAPACITY SIZE/WEIGHTMODEL REF POWER SIZE litres L mm W mm H mm kg(empty)
CT8-920 8 feet 920 2438 2200 2260 1100
CT15-4900 15 feet 4900 4550 2438 2591 2100
CT15-5659 15 feet 5659 4550 2438 2591 2100
CT15-7238 15 feet 7238 4550 2438 2591 2100
CT20-4900 20 feet 4900 6058 2438 2591 4000
CT20-5600 20 feet 5600 6058 2438 2591 4150
CT20-12000 20 feet 12000 6058 2438 2591 4300
CISTERNS IN CONTAINERSAREAS OF APPLICATION: External container tanks are used where a greater operating autonomy of power generation is needed, offering better protection againstatmospheric agents. Their sturdy structure allows them to operate effectively in difficult conditions (construction sites, isolated areas, etc.) and provides more efficientsafety measures to prevent theft and tampering, making them easy to transport and commission. They are available in different fuel capacities, from 920 to 12,000litres, according to the specific requirements, are built onboard ISO standard containers, and are equipped with a liquid retention basin.
MODEL CAPACITY SIZE/WEIGHTMODEL REF POWER SIZE litres L mm W mm H mm kg(empty)
CT8-920 8 feet 920 2438 2200 2260 1100
CT15-4900 15 feet 4900 4550 2438 2591 2100
CT15-5659 15 feet 5659 4550 2438 2591 2100
CT15-7238 15 feet 7238 4550 2438 2591 2100
CT20-4900 20 feet 4900 6058 2438 2591 4000
CT20-5600 20 feet 5600 6058 2438 2591 4150
CT20-12000 20 feet 12000 6058 2438 2591 4300
MOBILE LIGHTING TOWERSAREAS OF APPLICATION: Mobile lighting towers are designed to grant the highest working reliability under any conditions. Because of their flexibility and reliability,they are suitable for diverse sectors (construction sites, ports, airports, industrial plants, rental business) and highly appreciated in various applications (constructioncompanies, large-scale events and entertainment, fire-fighters, civil defence and disaster relief, just to name a few). They are equipped with sound-proofed electricitygenerators, mounted on special bases, and assembled with primary brand diesel engines and alternators. The presence of the generating unit enables continuous supplyto the lamps, as well as additional energy to supply other small loads. The control panels allow complete command, control and protection, while fully complying with theinternational standard rules and specifications.
MAIN FEATURES
-Zinc plating steel telescopic mast -Maximum height 9 mt (adjustable)-340° manual mast rotation-Extremely sturdy and compact-Mounted on a slow trailer-Sturdy road tires and mudguards-Max wind speed 80 km/h-Winch or hydraulic tower liftingSPECIAL CABINET-Hydraulic lifting system operated with a joystick, safety systemfor lowering (only in the hydraulic version)-Lamps switchesOTHER EQUIPMENT-4 adjustable stabilisers-Adjustable floodlights in horizontal and vertical positions-Adjustable stabiliser mounted on the tow bar
AVAILABLE LAMPS
METAL HALIDE LAMPS
AVAILABLE VERSIONS AND TECHNICAL DATAMODEL kVA/kW
PRPNumberof lamps
Lamppower
Luminousflux
RPM Cons.lt.h 50%
Cons.lt.h 75%
Cons.lt.h 100%
Fueltanklt.
Lmm
Wmm
Hmm
WEIGHTkg.
THREE-PHASE VERSIONS 400/231 Volt 50 HzPT-21 20.0-16.0 4 1000W 4200 m2 1500 2.9 4.0 5.4 50 4350 1600 2580
90001640
TRANSFORMER CABINSMAIN FEATURES
Medium voltage container-equipped transformer substations,complete with Low Voltage switches and Medium Voltage cells,ready for immediate connection. Available in both 20’ or 40’properly modified containers, they come with a set-up for thecable inlet and outlet feed through doors with extruded steelcounter-frames. They are also equipped with an internal lightingsystem, grounding, and a ventilation or cooling system. They areset up for a parallel connection on the medium voltage side of thecontainer through an additional identical transformer station. Thetransformer substations can be used both as voltage boosters oras transformer voltage reducers.
GENERAL TECHNICAL DATA
VERSION 2000 kVATYPE Container 20 feet
TOTAL WEIGHT 10.500 kg
COMPARTMENTS 2
INTERNAL LIGHTING 2 lamps, 36W
ACCESS in the front
INSTALLATION outdoor
AMBIENT TEMPERATURE AND HUMIDITY -20°C +45°C / 80%
ALTITUDE less than or equal to 100 mt s.l.m.
MANUFACTURING REFERENCE STANDARDS CEI 64-8, CEI 17-6, CEI 14-4, CEI 11-18, CEI –EN60439-1 low voltage switchgears, CEI-EN 62271-200
medium voltage switchgears
POWER RATING – FREQUENCY 2000kVA - 50 Hz
NEUTRAL GROUNDING Direct
IP DEGREE OF PROTECTION IP 54
TRANSFORMER POWER 2000 kVA
NOMINAL VOLTAGE 20 kV
NOMINAL CURRENT 400A
VERSION 2500 kVATYPE 20’ container
TOTAL WEIGHT 10.500 kg
COMPARTMENTS 2
EXTERNAL POWER SUPPLY UPS 230V 1 kVA min. autonomy
INTERNAL LIGHTING 2 lamps, 36W
ACCESS in the front
INSTALLATION outdoor
AMBIENT TEMPERATURE AND HUMIDITY -20°C +45°C / 80%
ALTITUDE less than or equal to 100 mt s.l.m.
MANUFACTURING REFERENCE STANDARDS CEI 64-8, CEI 17-6, CEI 14-4, CEI 11-18, CEI 016 lowvoltage switchgears, CEI –EN 60439-1 medium
voltage switchgears, CEI-EN 62271-200 mediumvoltage switchgears
POWER RATING – FREQUENCY 2500kVA / 50 Hz
NEUTRAL GROUNDING Direct
IP DEGREE OF PROTECTION IP54
TRANSFORMER POWER 2500 kVA
TYPE OF INSULATION Covered with resin
WINDING CONNECTION Dyn 11
NOMINAL VOLTAGE PRIMARY CIRCUIT LV 0.4 kV
CURRENT PRIMARY CIRCUIT LV 3608A
NOMINAL VOLTAGE SECONDARY CIRCUIT 20-15-11-6-3 kV
CURRENT PRIMARY CIRCUIT MV 72-96-131-240-481 A
TRANSFORMER CABINSMAIN FEATURES
Medium voltage container-equipped transformer substations,complete with Low Voltage switches and Medium Voltage cells,ready for immediate connection. Available in both 20’ or 40’properly modified containers, they come with a set-up for thecable inlet and outlet feed through doors with extruded steelcounter-frames. They are also equipped with an internal lightingsystem, grounding, and a ventilation or cooling system. They areset up for a parallel connection on the medium voltage side of thecontainer through an additional identical transformer station. Thetransformer substations can be used both as voltage boosters oras transformer voltage reducers.
GENERAL TECHNICAL DATA
VERSION 2000 kVATYPE Container 20 feet
TOTAL WEIGHT 10.500 kg
COMPARTMENTS 2
INTERNAL LIGHTING 2 lamps, 36W
ACCESS in the front
INSTALLATION outdoor
AMBIENT TEMPERATURE AND HUMIDITY -20°C +45°C / 80%
ALTITUDE less than or equal to 100 mt s.l.m.
MANUFACTURING REFERENCE STANDARDS CEI 64-8, CEI 17-6, CEI 14-4, CEI 11-18, CEI –EN60439-1 low voltage switchgears, CEI-EN 62271-200
medium voltage switchgears
POWER RATING – FREQUENCY 2000kVA - 50 Hz
NEUTRAL GROUNDING Direct
IP DEGREE OF PROTECTION IP 54
TRANSFORMER POWER 2000 kVA
NOMINAL VOLTAGE 20 kV
NOMINAL CURRENT 400A
VERSION 2500 kVATYPE 20’ container
TOTAL WEIGHT 10.500 kg
COMPARTMENTS 2
EXTERNAL POWER SUPPLY UPS 230V 1 kVA min. autonomy
INTERNAL LIGHTING 2 lamps, 36W
ACCESS in the front
INSTALLATION outdoor
AMBIENT TEMPERATURE AND HUMIDITY -20°C +45°C / 80%
ALTITUDE less than or equal to 100 mt s.l.m.
MANUFACTURING REFERENCE STANDARDS CEI 64-8, CEI 17-6, CEI 14-4, CEI 11-18, CEI 016 lowvoltage switchgears, CEI –EN 60439-1 medium
voltage switchgears, CEI-EN 62271-200 mediumvoltage switchgears
POWER RATING – FREQUENCY 2500kVA / 50 Hz
NEUTRAL GROUNDING Direct
IP DEGREE OF PROTECTION IP54
TRANSFORMER POWER 2500 kVA
TYPE OF INSULATION Covered with resin
WINDING CONNECTION Dyn 11
NOMINAL VOLTAGE PRIMARY CIRCUIT LV 0.4 kV
CURRENT PRIMARY CIRCUIT LV 3608A
NOMINAL VOLTAGE SECONDARY CIRCUIT 20-15-11-6-3 kV
CURRENT PRIMARY CIRCUIT MV 72-96-131-240-481 A
SOME REFERENCES:
Product and brand names are trademarks or registered trademarks of their respective companies and are used only for reference identification purpose.
SOME REFERENCES:
Product and brand names are trademarks or registered trademarks of their respective companies and are used only for reference identification purpose.
SOME REFERENCES:
Product and brand names are trademarks or registered trademarks of their respective companies and are used only for reference identification purpose.
SOME REFERENCES:
Product and brand names are trademarks or registered trademarks of their respective companies and are used only for reference identification purpose.