1 http://resi.lutron.com Technical Support: [email protected] INTRODUCTION SPECIFICATION & DESIGN FRONT ROOM BACK ROOM APPENDIX Remote Power Feed-Through Panels EIGHT-MODULE REMOTE POWER FEED-THROUGH PANEL (MODEL # HWI-PNL-8) Accommodates one of the following combinations of components: 1 8 Series processor 1 module interface Up to 8 remote Up to 8 remote power modules 1 power modules 1 1 One HW-HIFC-10-2 filter choke may be installed in place of module 8, see pg. 118 Remote power feed-through panels are available in two different sizes, each of which may be either surface- mounted or recess-mounted, in an electrical closet or other equipment room The number of remote power panels—and the types of components within them—may be specified to fit the size, lighting plan, and design of a home Remote power panels may be distributed through- out the home for added flexibility during installation of the line-voltage wiring Remote power feed-through panels may contain HomeWorks ® remote power modules and 8 Series processors or module interfaces A few of the possible configurations are shown below FIVE-MODULE REMOTE POWER FEED-THROUGH PANEL (MODEL # HWI-PNL-5) Accommodates the following combination of components: 1 module interface Up to 5 remote power modules Note: HWI-PNL-5 cannot house a HomeWorks Processor Note: HWI-KIT-RS232 can be installed in HWI-PNL-8, allowing for a connection to RS-232 port without removing the panel cover KIT FOR PERMANENT RS-232 CONNECTION IN HWI-PNL-8 (MODEL # HWI-KIT-RS232) RS-232 cable (provided) RS-232 Connector Bracket Connect Cable to Link 3 or 7 Mounting Screws (3) Module Interface Remote Power Modules (up to 5) Module Interface 8 Series processor Remote Power Modules (up to 8) Remote Power Modules (up to 8) 8 Series Panels & Enclosures N/A N/A or

Upload: trankhuong

Post on 01-Feb-2018

220 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Remote Power Feed-Through Panels - Lutron  · PDF fileRemote Power Feed-Through Panels EIGhT-MODUlE REMOTE POWER FEED-ThROUGh PANEl (MODEl # hWI-PNl-8) Accommodates one of

1��http://resi.lutron.com Technical Support: [email protected]

IN

TRO

DU

CTION

SP

ECIFICATIO

N &

DESIG

N

FRO

NT R

OO

M

BA

CK R

OO

M

A

PP

END

IX

Remote Power Feed-Through Panels

E I G h T - M O D U l E R E M O T E P O W E R F E E D - T h R O U G h P A N E l ( M O D E l # h W I - P N l - 8 )

Accommodates one of the following combinations of components:

• 1 8 Series processor • 1 module interface • Up to 8 remote • Up to 8 remote power modules1 power modules1

1 One HW-HIFC-10-2 filter choke may be installed in place of module 8, see pg. 118 .

Remote power feed-through panels are available in two different sizes, each of which may be either surface-mounted or recess-mounted, in an electrical closet or other equipment room . The number of remote power panels—and the types of components within them—may be specified to fit the size, lighting plan, and design of a home . Remote power panels may be distributed through-out the home for added flexibility during installation of the line-voltage wiring .

Remote power feed-through panels may contain HomeWorks® remote power modules and 8 Series processors or module interfaces . A few of the possible configurations are shown below .

F I v E - M O D U l E R E M O T E P O W E R F E E D - T h R O U G h P A N E l ( M O D E l # h W I - P N l - 5 )

Accommodates the following combination of components:

• 1 module interface• Up to 5 remote power modules

Note: HWI-PNL-5 cannot house a HomeWorks Processor

Note: HWI-KIT-RS232 can be installed in HWI-PNL-8, allowing for a connection to RS-232 port without removing the panel cover .

K I T F O R P E R M A N E N T R S - 2 3 2 C O N N E C T I O N I N h W I - P N l - 8 ( M O D E l # h W I - K I T - R S 2 3 2 )

RS-232 cable (provided)

RS-232 Connector

BracketConnect Cable to Link 3 or 7

Mounting Screws (3)

Module Interface

Remote Power Modules (up to 5)

Module Interface8 Series processor

Remote Power Modules (up to 8)

Remote Power Modules (up to 8)

8 Series

Panels & Enclosures

N/A

N/A

or

Page 2: Remote Power Feed-Through Panels - Lutron  · PDF fileRemote Power Feed-Through Panels EIGhT-MODUlE REMOTE POWER FEED-ThROUGh PANEl (MODEl # hWI-PNl-8) Accommodates one of

1�0 Technical Support • 24 Hours a Day/7 Days a Week • 1.800.523.9466

IN

TRO

DU

CTION

SP

ECIFICATIO

N &

DESIG

N

FRO

NT R

OO

M

BA

CK R

OO

M

A

PP

END

IX

Remote Power Feed-Through Panels (cont .)Model Number

Capacity

Regulatory Approvals

Environment

Cooling

Heat Generated Fully Loaded

Line-Voltage Connections

DIN Rail Terminal Blocks

Ground Bar Terminals

Miswire Protection

Mounting

Dimensions

Construction

Shipping Weight

HWI-PNL-8: Eight-Module Remote Power Feed-Through Panel .

Eight RPMs (HW-RPM-4A, HW-RPM-4U, HW-RPM-4FSQ, HW-RPM-4M, and HW-RPM-4R) in any combination and one module interface or 8 Series processor . See Fig. 3, pg. 151 .

UL, CSA, NOM

Ambient operating temperature: 0 °C to 40 °C, 32 °F to 104 °F Ambient operating humidity: 0-90% humidity, non-condensing . Indoor use only .

Passive cooling . Mount in a place where the vented cover will not be blocked .

750 BTUs per hr . maximum .

Use copper wire only, supply conductors 60 / 75 °C . DIN rail-mounted terminal blocks pro-vided for line-voltage remote power module wiring and processor/MI power . Terminal blocks should be tightened to 3 .5-5 .0 in .-lbs . (0 .40-0 .57 N•m) . See Fig. 2, pg. 151 .

Terminal blocks will accept one #18-10 AWG (1 .0-2 .5 mm2) wire or two #18-16 AWG (1 .0- 1 .5 mm2) wires . Terminal blocks should be tightened to 3 .5-5 .0 in .-lbs . (0 .40-0 .57 N•m) . All terminal blocks are shipped with bypass jumpers installed . After verifying that each circuit is wired correctly, remove the bypass jumpers for system operation .

24 ground termination points .

All terminal blocks are shipped with bypass jumpers installed .

May be surface-mounted or flush-mounted . Panel fits between standard 16 in (406 mm) on-center stud framing . When flush mounting in a 2x4 stud bay, to accomodate the depth of the panel – 41⁄8 in (10 .5 cm) – the sheetrock must be built out or a frame must be construct-ed . Panel must be mounted vertically (+/- 7 degrees from vertical) . Allow at least 12 in (30 cm) air space at top and bottom and a minimum of 12 in (30 cm) clearance in front of panel, or allow air space as required by local codes (whichever is greater) . Remote power panels will hum slightly and internal relays will click while in use . Mount where such noise is acceptable . Mount the panel so that line-voltage wiring will be at least 6 feet (1 .8 m) from audio or electronic equipment and its wiring .

143⁄8 in (36 .5 cm) x 59 in (150 cm) x 41⁄8 in (10 .5 cm) See Fig. 1, pg. 151 .

Enclosure: 16-gauge galvanized sheet metal (unpainted) . Cover: Painted (black) metal cover with ventilation holes .

Cover is attached using eight phillips-head screws .

25 lbs . (11 .4 kg) without RPMs

Page 3: Remote Power Feed-Through Panels - Lutron  · PDF fileRemote Power Feed-Through Panels EIGhT-MODUlE REMOTE POWER FEED-ThROUGh PANEl (MODEl # hWI-PNl-8) Accommodates one of

1�1http://resi.lutron.com Technical Support: [email protected]

IN

TRO

DU

CTION

SP

ECIFICATIO

N &

DESIG

N

FRO

NT R

OO

M

BA

CK R

OO

M

A

PP

END

IX

Note: The panel is 41⁄8 in (10.5 cm) deep past cover mounting tabs.Figure 1 – Panel Dimensions and Mounting

Screwsfor recess mounting (4 places)

8 in (20 cm)

21⁄2 in (6 cm)

413⁄4 in (106 cm)

143⁄4 in (37 cm)

11 in (22 cm)

143⁄8 in (36 .5 cm)

151⁄8 in (38 .5 cm)

59 in (150 cm)

5/16 in dia . (8 mm)

Mount Panel Vertically

Up

-7º +7º

5/8 in dia . (16 mm) Keyholes for surface mounting (4 places)

3/8 in (1 cm)

3/8 in (1 cm)

Remote Power Feed-Through Panels (cont .)

Figure � – Panel Configurations

1 One HW-HIFC-10-2 filter choke may be installed in place of module 8 .

• 1 8 Series processor• Up to 8 remote

power modules1

• 1 module interface• Up to 8 remote

power modules1

8 Series processor

Figure � – Wiring Entry

Preferred Power Wiring Entry

Module Locations (8 max .)

Terminal Blocks

Alternate Power Wiring Entry

Control Wiring Entry (NEC® Class 2)

Remote Power Modules (up to 8)

Remote Power Modules (up to 8)

Module Interface

or

Page 4: Remote Power Feed-Through Panels - Lutron  · PDF fileRemote Power Feed-Through Panels EIGhT-MODUlE REMOTE POWER FEED-ThROUGh PANEl (MODEl # hWI-PNl-8) Accommodates one of

1�� Technical Support • 24 Hours a Day/7 Days a Week • 1.800.523.9466

IN

TRO

DU

CTION

SP

ECIFICATIO

N &

DESIG

N

FRO

NT R

OO

M

BA

CK R

OO

M

A

PP

END

IX

Remote Power Feed-Through Panels (cont .)Model Number

Capacity

Regulatory Approvals

Environment

Cooling

Heat Generated Fully Loaded

Line-Voltage Connections

DIN Rail Terminal Blocks

Ground Bar Terminals

Miswire Protection

Mounting

Dimensions

Construction

Shipping Weight

HWI-PNL-5: Five-Module remote power feed-through panel .

Five RPMs (HW-RPM-4A, HW-RPM-4U, HW-RPM-4FSQ, HW-RPM-4M, and HW-RPM-4R) in any combination and one module interface . See Fig. 2, pg. 153 .

UL, CSA, NOM

Ambient operating temperature: 0 °C to 40 °C, 32 °F to 104 °F Ambient operating humidity: 0-90% humidity, non-condensing . Indoor use only .

Passive cooling . Mount in a place where the vented cover will not be blocked .

475 BTUs per hr . maximum .

Use copper wire only, supply conductors 60 / 75 °C . DIN rail-mounted terminal blocks provided for line-voltage remote power module wiring and processor/MI power . Terminal blocks should be tightened to 3 .5-5 .0 in .-lbs . (0 .40-0 .57 N•m) . See Fig. 2, 3 pg. 153 .

Terminal blocks will accept one #18-10 AWG (1 .0-2 .5 mm2) wire or two #18-16 AWG (1 .0- 1 .5 mm2) wires . Terminal blocks should be tightened to 3 .5-5 .0 in .-lbs . (0 .40-0 .57 N•m) . All terminal blocks are shipped with bypass jumpers installed . After verifying that each circuit is wired correctly, remove the bypass jumpers for system operation .

24 ground termination points .

All terminal blocks are shipped with bypass jumpers installed .

May be surface-mounted or flush-mounted . Panel fits between standard 16 in (406 mm) on-center stud framing . Panel must be mounted vertically (+/- 7 degrees from vertical) . Allow at least 12 in (30 cm) air space at top and bottom and a minimum of 12 in (30 cm) clearance in front of panel, or allow air space as required by local codes (whichever is greater) . Remote power panels will hum slightly and internal relays will click while in use . Mount where such noise is acceptable . Mount the panel so that line-voltage wiring will be at least 6 feet (1 .8 m) from audio or electronic equipment and its wiring .

143⁄8 in (36 .5 cm) x 32 in (81 cm) x 37⁄8 in (9 .8 cm) See Fig. 1, pg. 153 .

Enclosure: 16-gauge galvanized sheet metal (unpainted) . Cover: Painted (black) metal cover with ventilation holes .

Cover is attached using six phillips-head screws .

18 lbs . (8 .6 kg) without RPMs

Page 5: Remote Power Feed-Through Panels - Lutron  · PDF fileRemote Power Feed-Through Panels EIGhT-MODUlE REMOTE POWER FEED-ThROUGh PANEl (MODEl # hWI-PNl-8) Accommodates one of

1��http://resi.lutron.com Technical Support: [email protected]

IN

TRO

DU

CTION

SP

ECIFICATIO

N &

DESIG

N

FRO

NT R

OO

M

BA

CK R

OO

M

A

PP

END

IX

Note: The panel is 37⁄8 in (9.8 cm) deep past cover mounting tabs.Figure 1 – Panel Dimensions and Mounting

7 in (18 cm)

32 in (81 cm)

29 in (74 cm)

71⁄2 in (19 cm)

151⁄8 in (38 .54 cm)

Screwsfor recess mounting (4 places)

143⁄8 in (36 .5 cm)

Up

-7º +7º

Mount Panel Vertically

Remote Power Feed-Through Panels (cont .)

Figure � – Wiring Entry

Preferred Power Wiring Entry

Alternate Power Wiring Entry

Control Wiring Entry (NEC Class 2; IEC PELV)

Figure � – Panel Configuration

Terminal Blocks

HWI-MI-120 Module Interface

Module Locations (5 max)

• 1 Module Interface• Up to 5 Remote Power Modules

5/16 in dia . (8 mm)

5/8 in dia . (16 mm) Keyholes for surface mounting (4 places)