MET’S School ofEngineeringDept. of Electrical & ElectronicsEngineering
Group V
Alvasim P. A.Anumol R.
Geo JoyNimmy Yesudas
Pradeep K. Vijayan
![Page 4: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/4.jpg)
![Page 5: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/5.jpg)
CONTENTSIntroductionBlock DiagramBlock Diagram ExplanationCircuit DiagramAbout the CircuitWorkingApplicationsAdvantagesConclusionReference
![Page 6: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/6.jpg)
![Page 7: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/7.jpg)
INTRODUCTION The aim of this work is to design and constructa remote controlled fan regulator.This circuit allows total control over theequipments without having to move around.The frequency of remote used is typicallyaround
36 KHz.The remote control device sends an infra-redbeam, which is received by the infra-red sensoron the regulator thereby affecting the speed ofthe fan or intensity of light.
![Page 8: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/8.jpg)
![Page 9: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/9.jpg)
BLOCK DIAGRAM
![Page 10: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/10.jpg)
![Page 11: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/11.jpg)
![Page 12: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/12.jpg)
Infrared Receiver Module The infrared rays transmitted by the remotecontrol are received by IR Receiver.The component used here is capable ofreceiving signals up to 38 KHz.
![Page 13: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/13.jpg)
![Page 14: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/14.jpg)
![Page 15: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/15.jpg)
Monostable MultivibratorMonostable Multivibrator is used for getting anaccurate pulse.The trigger to this is the signals from receivermodule.The output of Monostable Multivibrator (IC1)isused to delay the clock pulse of decadecounter.
![Page 16: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/16.jpg)
![Page 17: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/17.jpg)
Decade Counter Decade counter is Mod-10 counter.The count is incremented with each clockpulse.
![Page 18: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/18.jpg)
TransformerThe 230 V AC is step down to 12V by theTransformer .
![Page 19: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/19.jpg)
![Page 20: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/20.jpg)
![Page 21: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/21.jpg)
Regulator Section The rectified output (12V) of the Transformer isregulated to 9V by the Regulator.This 9V is supplied to the whole circuit.
![Page 22: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/22.jpg)
![Page 23: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/23.jpg)
![Page 24: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/24.jpg)
Opto Coupler An Opto coupler is used to transmit eitheranalog or digital information from one voltagepotential to another while maintaining isolationof potentials. It is used for low voltages.The output of the Opto coupler is used totrigger the Monostable Multivibrator.
![Page 25: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/25.jpg)
![Page 26: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/26.jpg)
![Page 27: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/27.jpg)
Opto Isolator An Opto isolator is used to transmit
eitheranalog or digital information from one voltagepotential to another while maintaining isolationof the potentials.
Its operating voltage is higher than that of an Opto coupler.
The output of the Opto isolator is used to drivethe Triac.
![Page 28: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/28.jpg)
![Page 29: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/29.jpg)
Triac A Triac changes its state when its gate
receivesa current pulse. It is a Thyristor with a firing angle of
nearly45 .0
This firing angle determines the speed of thefan.
![Page 30: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/30.jpg)
CIRCUIT DIAGRAM
![Page 31: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/31.jpg)
![Page 32: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/32.jpg)
The circuit consists of a step down Transformer(12V-0-12V).
The diodes(D1-D6) and the capacitor(C9) constitutes the Rectifier & Filter
section. 7809 is a 9V Regulator. TSOP1738 is the infrared sensor. Zener Diode regulates the voltage across thesensor.
IC1 & IC3 are NE555 IC’s which are wired asMonostable Multivibrators.
IC2 is a Decade Counter. The diodes(D7-D11) & resistors(R5-R9) along withthe Capacitor C5 controls the pulse-width of IC2.
![Page 33: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/33.jpg)
![Page 34: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/34.jpg)
The Transistor(BC548) along with the ResistorsR10 & R11 acts as a switch.
MCT2E is an Opto coupler.
MOC3021 is an Opto isolator.
A Snubber Network consisting of a resistor &capacitor (R13 & C7) regulates the rate of
change of voltage across the Triac. The Triac BT136 regulates the speed of the
fanwith the variations in its firing angle.
![Page 35: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/35.jpg)
![Page 36: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/36.jpg)
WORKING Infrared receiver module TSOP1738 is used
toreceive the infrared signal transmitted byremote control.
The circuit is powered by regulated 9V.
The AC mains is stepped down and rectified.
Pulses from the IR receiver module trigger thetimer NE555 (IC1).
IC1 is wired as a Monostable Multivibrator todelay the clock given to decade counter-cum-
driver IC CD4017 (IC2).
![Page 37: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/37.jpg)
Combination of one of the resistors R5 throughR9 and capacitor C5 controls the pulse width.
NE555 timer (IC3) is wired as a MonostableMultivibrator.
MCT2E (IC5) is wired as a zero-crossingdetector that supplies trigger pulses to
Monostable Multivibrator IC3. MOC3021 (IC4) drives Triac
BT136.The variations in the firing angle affects thevoltage and thus the speed of the fan is varied.
![Page 38: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/38.jpg)
![Page 39: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/39.jpg)
APPLICATIONS Remote controlled Fan Regulator is used
tocontrol the speed of fan from our bed or couch. The same circuit finds its use to control
theIntensity of light at various levels. This circuit also finds it use for switching
ONand OFF any electronic circuit.
![Page 40: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/40.jpg)
![Page 41: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/41.jpg)
ADVANTAGES This circuit is simple to use and
efficient. It can be assembled with
ease. It is cheap and hence very
economic. It is small in
size.
![Page 42: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/42.jpg)
![Page 43: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/43.jpg)
CONCLUSION The speed of fan & intensity of light can
becontrolled in various levels from off position tomaximum intensity possible.
So it finds its use as night lamp by keeping theintensity of lamp in low level.
The circuit also finds its use for switching ONand OFF any electronic circuitry.
Our normal T.V. remote can be used for thispurpose.
![Page 44: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/44.jpg)
![Page 45: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/45.jpg)
REFERENCE www.electronicsforyou.co
m www.howstuffworks.co
m Linear Integrated circuits –
Gaykwad Electronic Devices and Circuits – J.
B.Gupta
![Page 46: Remote-Controlled-Fan-Regulator](https://reader035.vdocuments.site/reader035/viewer/2022070300/543dba1eb1af9f350a8b4b71/html5/thumbnails/46.jpg)