reinsurance group of america (rga) global headquarters
DESCRIPTION
Reinsurance Group of America (RGA) Global Headquarters. General Building Info. Steel superstructure with braced frames Concrete parking garage with shear walls. Braced frames and shear walls act together Cantilever Truss System. Existing System-Composite Steel. Typical bay - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Reinsurance Group of America (RGA) Global Headquarters](https://reader035.vdocuments.site/reader035/viewer/2022062323/56816743550346895ddbf78d/html5/thumbnails/1.jpg)
Reinsurance Group of America (RGA) Global Headquarters
![Page 2: Reinsurance Group of America (RGA) Global Headquarters](https://reader035.vdocuments.site/reader035/viewer/2022062323/56816743550346895ddbf78d/html5/thumbnails/2.jpg)
General Building Info
• Steel superstructure with braced frames
• Concrete parking garage with shear walls
• Braced frames and shear walls act together
• Cantilever Truss System
![Page 3: Reinsurance Group of America (RGA) Global Headquarters](https://reader035.vdocuments.site/reader035/viewer/2022062323/56816743550346895ddbf78d/html5/thumbnails/3.jpg)
Existing System-Composite Steel• Typical bay• 2 hour fire rating• 49.0 psf• $39.73/SF• 30” Depth• Deck unshored• Oversized for strength• Deflections pass
comfortably
![Page 4: Reinsurance Group of America (RGA) Global Headquarters](https://reader035.vdocuments.site/reader035/viewer/2022062323/56816743550346895ddbf78d/html5/thumbnails/4.jpg)
Alternate 1-Floor Joists on Beams
• 2 hour fire rated deck, but joists difficult to fireproof effectively
• 48.5 psf ~ Existing• $39.73/SF < Existing• 34.5” depth > Existing• Lateral load path
unchanged
![Page 5: Reinsurance Group of America (RGA) Global Headquarters](https://reader035.vdocuments.site/reader035/viewer/2022062323/56816743550346895ddbf78d/html5/thumbnails/5.jpg)
Alternate 2-Hollow Core on Beams
• 2 hour fire rating• 107.8 psf >> Existing• $56.70/SF >> Existing• 42” >> Existing• Not a viable option• Lateral load path
unchanged
![Page 6: Reinsurance Group of America (RGA) Global Headquarters](https://reader035.vdocuments.site/reader035/viewer/2022062323/56816743550346895ddbf78d/html5/thumbnails/6.jpg)
Alternate 3- One-Way Slab with Beams
• 2 hour fire rating• 101.2 psf >> Existing• $31.23/SF < Existing• 32” > Existing• Viable, but weight will
impact garage• Shear walls in parking
garage and through the superstructure’s core
![Page 7: Reinsurance Group of America (RGA) Global Headquarters](https://reader035.vdocuments.site/reader035/viewer/2022062323/56816743550346895ddbf78d/html5/thumbnails/7.jpg)
Final System ComparisonExisting Floor Joists Hollow Core One-Way Slab
Weight 49.0 psf 48.5 psf 107.8 psf 101.2 psf
Cost $39.73/SF $37.18/SF $56.70/SF $31.23/SF
System Depth 30” 34.5” 42” 32”
Fire Protection 2 Hour 2 Hour* 2 Hour 2 Hour
Deflections (LL) 0.375” 0.58” 0.804” 0.586”
Viable? Benchmark Yes No Yes