Reinforced concrete reinvented Jeroen Smet

Upload: danghanh

Post on 25-Jul-2018

230 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Reinforced concrete reinvented

Jeroen Smet

Page 2: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Let’s presume

• You all know the benefits of using FRC:• Installation time is 50% of steel mesh• 0% corrosion • 15-40% cheaper solution than steel mesh• 100% Safer

Page 3: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

ASTM C 78, JSCE-SF4

Residual Flexural strength

• Concrete = brittle• The bond between the cement and the aggregate => strength

Page 4: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

ASTM C 78, JSCE-SF4

Flexural Strength is NOT Increased

Flexural Strain Capacity ISEnhanced

Residual Flexural strength

• FRC => Residual Flexural strength• Fibres take the tension and transfer this tension to un-cracked

areas

Page 5: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Cracks are held together

Residual flexural strength

Page 6: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Test set-up Plain Concrete FRC

Beam test

Brittle Flexural strength

Residual Flexural strength

Page 7: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Residual Flexural Strength

• Re3-value: residual flexural strenght• 3 point bending test• Determined @WTCB

Page 8: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Residual Flexural strength

Page 9: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Design: Slab on grade

Page 10: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Design Service

• Supported floor slab:• Done against CS-TR34-4th edition• In line with the latest Eurocodes and Standards• Limit state format: ULS and SLS• ULS => Meyerhof equations (Partial Safety Factors acc. EC2)

Page 11: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Design service

Comparison of different design methodologies for FRC Slabs on grade - Sunitha K Nayar and Ravindra Gettu

Page 12: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Design service

• ConCribe:• Engineering buro• Experienced with FRC• Floors – Precast designs• PI

• Own Software (sLade) designed by ConCribe• Supported FRC slab• PI • Very fast respons

Page 13: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Design: Slab on grade

Page 14: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Increase energy absorption

Page 15: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Increase energy absorption

• Shotcrete for tunneling requires energy absorption (500,700 &1000 Joule)

• EFNARC plate test ASTM C1550 RDP TEST

Page 16: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Increase energy absorption

Page 17: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Improved impact resistance16mm rebar reinforcement

Page 18: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Improved impact resistanceFibre reinforcement

Page 19: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Improved impact resistanceFibre reinforcement

Page 20: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Improved impact resistanceFibre reinforcement

Page 21: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Durability

• Polypropylene = inert

• Durability of PP fibers in portland cement-based composites: eighteen years of data –D.J. Hannant

• Can be influenced in time by:

• UV radiation

• Oxidation

• Accelerated aging test: EN ISO 13438

• Service life: 25, 50 and 100 years

• 50% residual tensile strength

• S500 lost 32% strength and only 7,1% Modulus (100 years)

Page 22: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Durability

Page 23: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Creep

General:

• Not taken into account in MC 2010• International round robin test (19 labs) supported by RILEM TC

261-CCF• Improving knowledge on creep behaviour of FRC (Steel &

Polymer)• Check different test methodologies

Page 24: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Creep

In Adfil:

• Different fibre generations have been tested• Continiously improved• Phd @ KU Leuven

Page 25: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Creep

Fibre level:

Page 26: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Creep

Focus on segments not subjected to creep:- Flooring & foundations- Shotcrete(1)

- Precast(2)

Structural applications: hybrid reinforcement(3)

(1) Influence of Fibres on the Creep Behaviour of Reinforced Sprayed Concrete presented by Catharine Larive on WTC 2016

(2) PP FRC concrete pipes under sustained loading presented by Emmanuel Attiogbe on BEFIB 2016

(3) Brittle vs. ductile behavior of concrete beams reinforced with steel rebars and fibersGorino, A., Fantilli, A., Chiaia, B., Zampini, D.,

Page 27: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Creep

Creep test on concrete tubes:

- Primary reinforcement

- Longtherm serviceability factor α

- a ≥ 0,90 provides sufficient longtherm post-crack strength

- ASTM C1818 prequalify synthetic fibres for use as primary reinforcement

Page 28: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Applications

• Seawall defence• 4000m³• 4kg/m³• Eleminate corrosion

Page 29: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Applications

• Screed topping 50mm• Not enough covering for steel• 2400m³• 5kg/m³

Page 30: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Applications

• Extruded concrete• >100 Tonnes

Page 31: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Applications

• Housing• Durus S400 adopted as standard

reinforcement in beam and block floors by NHBC

• 4kg/m³

Page 32: Reinforced concrete reinvented - betonica.net · Design Service • Supported floor slab: ... (Partial Safety Factors acc. EC2) ... Brittle vs. ductile behavior of concrete beams

Thank you

Jeroen SmetProduct/Application Managerwww.adfil.be