rehabilitation of medium-head hydropower · pdf filerehabilitation of medium-head hydropower...

Download REHABILITATION OF MEDIUM-HEAD HYDROPOWER · PDF fileREHABILITATION OF MEDIUM-HEAD HYDROPOWER PLANTS WITH EXPLOITED TWIN-FRANCIS TURBINES. Maciej Kaniecki, ... Turbine type 2 x Twin

If you can't read please download the document

Upload: buinhan

Post on 12-Feb-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

  • REHABILITATION

    OF MEDIUM-HEAD HYDROPOWER PLANTS

    WITH EXPLOITED TWIN-FRANCIS TURBINES.

    Maciej Kaniecki, PhD

    Andrzej ojek, PhD

    Marusz Hajdarowicz, M.Sc.Eng

    Congress SHP, Grenoble 9-10 April 2014

    ZRE Gdask S.A.

    ul. Litewska 14A

    80-719 Gdask

  • ZRE GDANSK Company Profile

    ZRE Gdask S.A., st. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

    1. Production of hi-efficiency, ecological water

    turbines up to 10 MW (Francis and Kaplan)

    2. Upgrades of Hydro Power Plants

    up to 800 MW

    3. Diagnostics services

    (DT & NDT testing)

    4. Turnkey projects, repairs, servicing

  • ZRE Gdask S.A., st. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

    AGENDA

    1. Main reasons for rehabilitation

    2. Refurbishment vs. complete

    rebuilding

    3. Rehabilitation project stages

    4. Case study 1:

    upgrade of HPP Grdek,

    5. Case study 2:

    upgrade of HPP Kamienna.

  • Main reasons for rehabilitation

    of old twin Francis turbines

    Bad condition of metal parts and flow passages

    Erosion and cavitation damages in the flow passages

    Low efficiency of whole generating set

    Low energy production

    ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

  • ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

    Minimized scope of civil works

    Re-use of existing generator

    Following cultural heritage

    protection policies

    Refurbishment vs. complete rebuilding

    of the power plant

  • ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

    Stages of the rehabilitation project

    3D Design process

    Manufacturing and assembly

    of new parts

  • ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

    Performance guarantees, confirmed in acceptance tests

    Refurbishment unit-by-unit, without complete plant outage

  • Case study 1: upgrade of HPP Grdek

    Turbine type 2 x Twin Francis

    Gross head H 18 [m]

    Rated output power P 2 x 1.45 [MW]

    Installed discharge Q 2 x 9.7 [m3/s]

    Rotational speed 300 [rpm]

    ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

  • New, re-engineered runners and guide vanes,

    Refurbishment of the bearings,

    Repairs of other parts:

    shafts,

    camelback suction pipes

    guide vanes control system

    Upgrade of control and power output systems .

    ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

  • Design solutions 3D project

    based on CFD designed flow passages

    ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

  • Manufacturing of the runners

    ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

  • Guide vanes system for HPP Grdek

    ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

  • Acceptance tests of HPP Grdek Weighted efficiency

    Guaranteed value Measured value

    84.0 % 86.2 %

    ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

    65

    70

    75

    80

    85

    90

    3 4 5 6 7 8 9 10 11

    [%]

    Measured efficiency

    Q [m3/s]

  • Bearing type:

    Vibrations velocity

    [mm/s]

    Measured values of vibrations velocity

    Reference values

    ISO 7919-1

    Thrust bearing 0.3

  • Case study 2: upgrade of HPP Kamienna

    ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

    Turbine type Twin Francis

    Gross head H 7.3 [m]

    Rated output power P 2 x 0.52 [MW]

    Installed discharge Q 2 x 9.5 [m3/s]

    Rotational speed 100 [rpm]

  • Design solutions

    based on CFD analysis of flow passages

    ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

    Upgrade of flow systems:

    new runners

    new guide vanes

    new camelback draft tubes

    Manufacturing of new shafts

    Refurbishment of bearings

    Repairs of guide vanes control system

    Rewinding and upgrade of generators

    Renovation of the concrete

  • Old fashion runner with 32 blades

    Brand new runner with 13 blades

    Runners in HPP Kamienna

    ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

  • Old fashion guide vane Brand new guide vane

    Guide vanes of HPP Kamienna

    ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

  • New camelback draft tubes

    New casted parts

    ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

    Damaged parts of old camelback draft tubes

  • Installation of new units (HPP Kamienna)

    ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

  • ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

    Acceptance tests of HPP Kamienna

    combined weighted efficiency

    Guaranteed value Measured value

    82.8 % 85.4 %

    60

    65

    70

    75

    80

    85

    90

    3 5 7 9 11

    Q [m3/s]

    [%]

    Measured values of efficiency

    Measured values of efficiency prior to rehabilitation

  • Considerably low civil engineering activities,

    re-use of many parts and equipment of twin-Francis

    = significant reduction of investments costs of HPP modernization.

    Choice between twin-Francis upgrade and complete plant rebuilding with use of full Kaplan turbines

    should be considered due to lower investment costs, legal limitations and cultural heritage protection

    Summary

    ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

  • ZRE Gdask S.A., ul. Litewska 14A, 80-719 Gdask

    E-mail: [email protected]

    Thank you