rehabiliation and strengthening of rcc structures by using frp composites

13
International Journal of Emerging Technology and Advanced Engineering Website: www.ijetae.com (ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 3, Issue 10, October 2013) 261 Rehabilitation and Strengthening of R.C.C. STRUCTURES by using FRP composites Rahul kumar satbhaiya 1 , Shishir gupta 2 , T.R Arora 3 1 M.Tech Scholar CTM, LNCT Bhopal (M. P.) 2 Asst Proff LNCT Bhopal (M.P.) 3 H.O.D Department Of Civil Engg. LNCT Bhopal (M.P.) AbstractFiber Reinforced Polymer (FRP) as an external reinforcement is used extensively to deal with the strength requirements related to flexure and shear in structural systems. But the strengthening of members subjected to torsion is explored only recently. Torsion failure is an undesirable brittle form of failure which should be avoided specially in the earthquake prone areas. In the present work, the behaviour and performance of rectangular reinforced concrete beams strengthened with externally bonded Fibre Reinforced Polymer (FRP) fabrics subjected to combined flexure and torsion is studied experimentally. Three sets of concrete cylinders were tested for their ultimate strengths. In SET I three concrete cylinders (F1, F2 and F3) are tested. In SET II three concrete cylinders (S1, S2 and S3) are tested. In SET III three concrete cylinders (R1, R2 and R3) are tested. The concrete cylinders F1, S1 and C1 were taken as the control concrete cylinders. It was observed that the concrete cylinders F1, S1 and C1 had less load carrying capacity when compared to that of the externally strengthened beams using FRP sheets. In SET I concrete cylinders F2 is strengthened only single warp of FRP sheet on the full dimensions of concrete cylinders and F3 is strengthened by double warp of FRP sheet on the full dimensions of concrete cylinders. In SET II concrete cylinders S2 is strengthened only single warp of FRP sheet on the full dimensions of concrete cylinders and S3 is strengthened by double warp of FRP sheet on the full dimensions of concrete cylinders. In SET III concrete cylinders R2 is strengthened only single warp of FRP sheet on the full dimensions of concrete cylinders and R3 is strengthened by double warp of FRP sheet on the full dimensions of concrete cylinders. The ultimate load carrying capacities of all the concrete cylinders are calculated. Experimental data on ultimate cracking loads of each of the cylinders were obtained. The effect of different types and configuration of FRP and ultimate load carrying capacity of the cylinders were investigated. KeywordsConcrete, Cylinder, Failure, Fibre, Polymer, Reinforced I. INTRODUCTION This The maintenance, rehabilitation and upgrading of structural members, is perhaps one of the most crucial problems in civil engineering applications. Moreover, a large number of structures constructed in the past using the older design codes in different parts of the world are structurally unsafe according to the new design codes. Since replacement of such deficient elements of structures incurs a huge amount of public money and time, strengthening has become the acceptable way of improving their load carrying capacity and extending their service lives. Infrastructure decay caused by premature deterioration of buildings and structures has lead to the investigation of several processes for repairing or strengthening purposes. One of the challenges in strengthening of concrete structures is selection of a strengthening method that will enhance the strength and serviceability of the structure while addressing limitations such as constructability, building operations, and budget. Previously, the retrofitting of reinforced concrete structures, such as columns, beams and other structural elements, was done by removing and replacing the low quality or damaged concrete or/and steel reinforcements with new and stronger material. However, with the introduction of new advanced composite materials such as fiber reinforced polymer (FRP) composites, concrete members can now be easily and effectively strengthened using externally bonded FRP composites. Retrofitting of concrete structures with wrapping FRP sheets provide a more economical and technically superior alternative to the traditional techniques in many situations because it offers high strength, low weight, corrosion resistance, high fatigue resistance, easy and rapid installation and minimal change in structural geometry. In addition, FRP manufacturing offers a unique opportunity for the development of shapes and forms that would be difficult or impossible with the conventional steel materials. Although the fibers and resins used in FRP systems are relatively expensive compared with traditional strengthening materials, labour and equipment costs to install FRP systems are often lower. FRP systems can also be used in areas with limited access where traditional techniques would be impractical.

Upload: nanban-vijay

Post on 21-May-2017

250 views

Category:

Documents


14 download

TRANSCRIPT

Page 1: Rehabiliation and Strengthening of Rcc Structures by Using Frp Composites

International Journal of Emerging Technology and Advanced Engineering

Website: www.ijetae.com (ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 3, Issue 10, October 2013)

261

Rehabilitation and Strengthening of R.C.C. STRUCTURES by

using FRP composites

Rahul kumar satbhaiya1, Shishir gupta

2, T.R Arora

3

1M.Tech Scholar CTM, LNCT Bhopal (M. P.)

2Asst Proff LNCT Bhopal (M.P.)

3H.O.D Department Of Civil Engg. LNCT Bhopal (M.P.)

Abstract— Fiber Reinforced Polymer (FRP) as an external

reinforcement is used extensively to deal with the strength

requirements related to flexure and shear in structural

systems. But the strengthening of members subjected to

torsion is explored only recently. Torsion failure is an

undesirable brittle form of failure which should be avoided

specially in the earthquake prone areas. In the present work,

the behaviour and performance of rectangular reinforced

concrete beams strengthened with externally bonded Fibre

Reinforced Polymer (FRP) fabrics subjected to combined

flexure and torsion is studied experimentally.

Three sets of concrete cylinders were tested for their

ultimate strengths. In SET I three concrete cylinders (F1, F2

and F3) are tested. In SET II three concrete cylinders (S1, S2

and S3) are tested. In SET III three concrete cylinders (R1, R2

and R3) are tested. The concrete cylinders F1, S1 and C1 were

taken as the control concrete cylinders. It was observed that

the concrete cylinders F1, S1 and C1 had less load carrying

capacity when compared to that of the externally

strengthened beams using FRP sheets. In SET I concrete

cylinders F2 is strengthened only single warp of FRP sheet on

the full dimensions of concrete cylinders and F3 is

strengthened by double warp of FRP sheet on the full

dimensions of concrete cylinders. In SET II concrete

cylinders S2 is strengthened only single warp of FRP sheet on

the full dimensions of concrete cylinders and S3 is

strengthened by double warp of FRP sheet on the full

dimensions of concrete cylinders. In SET III concrete

cylinders R2 is strengthened only single warp of FRP sheet on

the full dimensions of concrete cylinders and R3 is

strengthened by double warp of FRP sheet on the full

dimensions of concrete cylinders. The ultimate load carrying

capacities of all the concrete cylinders are calculated.

Experimental data on ultimate cracking loads of each of

the cylinders were obtained. The effect of different types and

configuration of FRP and ultimate load carrying capacity of

the cylinders were investigated.

Keywords— Concrete, Cylinder, Failure, Fibre, Polymer,

Reinforced

I. INTRODUCTION

This The maintenance, rehabilitation and upgrading of

structural members, is perhaps one of the most crucial

problems in civil engineering applications.

Moreover, a large number of structures constructed in

the past using the older design codes in different parts of

the world are structurally unsafe according to the new

design codes. Since replacement of such deficient elements

of structures incurs a huge amount of public money

and time, strengthening has become the acceptable way of

improving their load carrying capacity and extending their

service lives. Infrastructure decay caused by premature

deterioration of buildings and structures has lead to the

investigation of several processes for repairing or

strengthening purposes. One of the challenges in

strengthening of concrete structures is selection of a

strengthening method that will enhance the strength and

serviceability of the structure while addressing limitations

such as constructability, building operations, and budget.

Previously, the retrofitting of reinforced concrete

structures, such as columns, beams and other structural

elements, was done by removing and replacing the low

quality or damaged concrete or/and steel reinforcements

with new and stronger material. However, with the

introduction of new advanced composite materials such as

fiber reinforced polymer (FRP) composites, concrete

members can now be easily and effectively strengthened

using externally bonded FRP composites.

Retrofitting of concrete structures with wrapping FRP

sheets provide a more economical and technically superior

alternative to the traditional techniques in many situations

because it offers high strength, low weight, corrosion

resistance, high fatigue resistance, easy and rapid

installation and minimal change in structural geometry. In

addition, FRP manufacturing offers a unique opportunity

for the development of shapes and forms that would be

difficult or impossible with the conventional steel

materials. Although the fibers and resins used in FRP

systems are relatively expensive compared with traditional

strengthening materials, labour and equipment costs to

install FRP systems are often lower. FRP systems can also

be used in areas with limited access where traditional

techniques would be impractical.

Page 2: Rehabiliation and Strengthening of Rcc Structures by Using Frp Composites

International Journal of Emerging Technology and Advanced Engineering

Website: www.ijetae.com (ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 3, Issue 10, October 2013)

262

II. LITREAURE

A review of some significant experimental investigations

conducted using steel plates is presented to demonstrate

some of the structural implications of external plating.

Research work into the performance of members

strengthened with steel plates was pioneered

simultaneously in South Africa and France in the 1960s

(L’Hermite and Bresson, 1967; Fleming and King,1967;

Lerchenthal,1967; Gilibert et al.,1976). Continued

development of suitable adhesives and the increased use of

the technique in practice stimulated further research work.

Eberline et al. (1988) present a literature review on

research and applications related to steel plate

bonding.Preliminary studies were conducted by Irwin

(1975). Macdonald (1978) and Macdonald and Calder

(1982) reported four point loading tests on steel plated RC

beams of length 4900mm. These beams were used to

provide data for the proposed strengthening of the Quinton

Bridges (Raithby, 1980 and 1982), and incorporated two

different epoxy adhesives, two plate thicknesses of 10.0mm

and 6.5mm giving width-to-thickness (b/t) ratios of 14 and

22, and a plate lap-joint at its centre. In all cases it was

found that failure of the beams occurred at one end by

horizontal shear in the concrete adjacent to the steel plate,

commencing at the plate end and resulting in sudden

separation of the plate with the concrete still attached, up to

about mid-span. The external plate was found to have a

much more significant effect in terms of crack control and

stiffness. The loads required to cause a crack width of

0.1mm were increased by 95%, whilst the deflections under

this load were substantially reduced. The post cracking

stiffness was found to be increased by between 35-

105% depending upon the type of adhesive used and the

plate dimensions. The features of this work became the

subject of a more detailed programme of research at the

TRRL (Macdonald, 1982; Macdonald and Calder, 1982), in

which a series of RC beams of length 3500mm were tested

in four point bending. The beams were either plated as-cast

or plated after being loaded to produce a maximum crack

width of 0.1mm. The effect of widening the plate whilst

maintaining its cross-sectional area constant was studied. It

was found that the plated as-cast and the pre-cracked beams

gave similar load/deflection curves, demonstrating the

effectiveness of external plating for strengthening purposes.

The benefits of utilising FRP materials over steel in plate

bonding applications are thus clear. The drawbacks are the

intolerance to uneven bonding surfaces which may cause

peeling of the plate, the possibility of brittle failure modes

(Swamy and Mukhopadhyaya, 1995) and the material cost,

since fiber composites are between 4-20 times as expensive

as steel in terms of unit volume.

However, in a rehabilitation project, where material

costs rarely exceed 20% of the overall project cost, the

installation savings can offset the higher material costs

(Meier, 1992). Peshkam and Leeming (1994) have

considered the commercial viability of FRP plate bonding

for bridge strengthening. In a straight comparison with steel

plate bonding for a typical application, despite the fact that

material costs will be increased, labour and equipment

costs will be reduced, construction times will be shorter

and durability will be improved. It is shown that 2kg of

FRP could replace 47kg of steel on an equal strength basis.

The costs of installing both materials are shown to be

similar; however, when traffic management, traffic delay

and maintenance costs are included, the use of FRP

provides a saving of 17.5% over steel. There are situations

where steel plate bonding is not a viable option because of

the extent of chloride contamination of the concrete. In

such cases, the use of FRP may avoid the need for

demolition and replacement. Peshkam and Leeming (1994)

presented a cost comparison of bridge replacement against

strengthening with FRP, in which possible savings of 40%

are demonstrated. These cost comparisons were made

before true manufacturing and installation costs were

known and were at the best estimates. Subsequently the

tendering process for real installation projects has shown

carbon fiber reinforced polymer (CFRP) plate bonding to

be very competitive against steel plate bonding in first cost,

before even future maintenance costs are added to the

whole life cost equation.

Saadatmanesh and Ehsani (1991) conducted an

xperimental study of the strengthening of reinforced

concrete beams using non-prestressed and prestressed

GFRP plates. One of the two prestressed beams contained a

relatively small amount of internal tensile steel

reinforcement, while the other contained larger bars and

was precracked prior to bonding of the plate. The plate

prestress in the precracked case closed some of the cracks,

indicating the benefit of prestressing from a serviceability

point of view. The beam with little original reinforcement

before plating experienced a large improvement in ultimate

capacity due to the additional moment couple provided by

the plate prestress. In both cases, the prestress was

generated by cambering the beam before bonding the plate

so that a tensile load was transferred to the plate when the

camber was released. Improved concrete crack control was

observed with prestressed plates, a clear advantage from a

serviceability point of view. A previous experimental study

by Saadatmanesh and Ehsani (1990) also included the

prestressing of a beam by cambering; this particular

specimen had a low internal reinforcement area ratio of

0.32% (based on effective depth) so that a very high

increase in ultimate load (323%) was observed as a result.

Page 3: Rehabiliation and Strengthening of Rcc Structures by Using Frp Composites

International Journal of Emerging Technology and Advanced Engineering

Website: www.ijetae.com (ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 3, Issue 10, October 2013)

263

The GFRP plate was not anchored at its ends, and failure

occurred by premature plate separation associated with the

removal of a layer of concrete from the tension face of the

beam.

III. EXPERIMENTAL STUDY

The experimental study consists of casting of three sets

of reinforced concrete (RC) cylinders of size 150mm

diameter and 300mm height. In SET I three cylinders of M-

15 grade of concrete were casted, out of which one is

unreinforced and other two were strengthened using

continuous fiber reinforced polymer (FRP) sheets. In SET

II three cylinders of M-20 grade of concrete weak in shear

were casted, out of which one is the unreinforced and other

two were strengthened by using continuous fiber reinforced

polymer (FRP) sheets in shear. In SET III three cylinders of

M-25 grade of concrete weak in shear were casted, out of

which one is the unreinforced and other two were

strengthened by using continuous fiber reinforced polymer

(FRP) sheets in shear. The strengthening of the cylinder is

done with varying configuration and layers of FRP sheets.

Experimental data on load and failure modes of each of the

cylinder were obtained. The change in load carrying

capacity and failure mode of the cylinder are investigated

as the amount and configuration of FRP sheets are altered.

The following chapter describes in detail the experimental

study. In this study we have taken four cases for checking

the strength of unreinforced concrete cylinders over the

reinforced concrete cylinders with FRP (Fiber Reinforced

Plastic) sheets. In each case we have taken three sets of

concrete cylinders having different grades of concrete. All

experimental details given in table below.

Table 3.1

Case study details

CASE NO. LOCATIO

N

DETAILS

Case-I Sagar (M.P.)

Experimental grades

of Concrete M-15, M-

20 and M-25

Case-II Sagar (M.P.)

Experimental grades

of Concrete M-15, M-

20 and M-25

Case-III Bhopal

(M.P.)

Experimental grades

of Concrete M-15, M-

20 and M-25

Case-IV Bhopal

(M.P.)

Experimental grades

of Concrete M-15, M-

20 and M-25

All the specimens were tested in the “Structural

Engineering” Laboratory of Gov. Engg. College SAGAR

(M.P.). The testing procedure for the entire specimen was

same. After the curing period of 28 days was over, the as

washed and its surface was cleaned for clear visibility of

cracks. The most commonly used load arrangement for

testing of cylinders will consist of compression testing

machine loading. Before testing the member was

checked dimensionally, and a detailed visual inspection

made with all information carefully recorded. Loads will

then normally be increased again in similar increments up

to failure, cracking and manual strain observations must be

suspended as failure approaches unless special safety

precautions are taken. If it is essential that precise

deflection readings are taken up to collapse. Cracking and

failure mode was checked visually, and a load/deflection

plot was prepared.

To meet the wide range of needs which may be required

in fabricating composites, the industry has evolved over a

dozen separate manufacturing processes as well as a

number of hybrid processes. Each of these processes offers

advantages and specific benefits which may apply to the

fabricating of composites. Hand lay-up and spray-up are

two basic moulding processes. The hand lay-up process is

the oldest, simplest, and most labour intense fabrication

method. The process is most common in FRP marine

construction. In hand lay-up method liquid resin is placed

along with reinforcement (woven glass fiber) against

finished surface of an open mould. Chemical reactions in

the resin harden the material to a strong, light weight

product. The resin serves as the matrix for the reinforcing

glass fibers, much as concrete acts as the matrix for steel

reinforcing rods. The percentage of fiber and matrix was

50:50 in weight.

The following constituent materials were used for

fabricating the plate:

1. E-glass woven roving as reinforcement

2. Epoxy as resin

3. Hardener as diamine (catalyst)

4. Polyvinyl alcohol as a releasing agent

Contact moulding in an open mould by hand lay-up was

used to combine plies of woven roving in the prescribed

sequence. A flat plywood rigid platform was selected. A

plastic sheet was kept on the plywood platform and a thin

film of polyvinyl alcohol was applied as a releasing agent

by use of spray gun. Laminating starts with the application

of a gel coat (epoxy and hardener) deposited on the mould

by brush, whose main purpose was to provide a smooth

external surface and to protect the fibers from direct

exposure to the environment.

Page 4: Rehabiliation and Strengthening of Rcc Structures by Using Frp Composites

International Journal of Emerging Technology and Advanced Engineering

Website: www.ijetae.com (ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 3, Issue 10, October 2013)

264

Ply was cut from roll of woven roving. Layers of

reinforcement were placed on the mould at top of the gel

coat and gel coat was applied again by brush. Any air

which may be entrapped was removed using serrated steel

rollers. The process of hand lay-up was the continuation of

the above process before the gel coat had fully hardened.

Again, a plastic sheet was covered the top of plate by

applying polyvinyl alcohol inside the sheet as releasing

agent. Then, a heavy flat metal rigid platform was kept top

of the plate for compressing purpose. The plates were left

for a minimum of 48 hours before being transported and

cut to exact shape for testing.

FIG 3.1-Application of epoxy and hardener on the

concrete structure

FIG -3.2 Fixing of FRP sheet on the concrete structure

IV. RESULTS

Three sets of concrete cylinders were tested for their

ultimate strengths. In SET I three concrete cylinders (F1,

F2 and F3) are tested. In SET II three concrete cylinders

(S1, S2 and S3) are tested. In SET III three concrete

cylinders (R1, R2 and R3) are tested.

The concrete cylinders F1, S1 and C1 were taken as the

control concrete cylinders. It was observed that the

concrete cylinders F1, S1 and C1 had less load carrying

capacity when compared to that of the externally

strengthened beams using FRP sheets. In SET I concrete

cylinders F2 is strengthened only single warp of FRP sheet

on the full dimensions of concrete cylinders and F3 is

strengthened by double warp of FRP sheet on the full

dimensions of concrete cylinders. In SET II concrete

cylinders S2 is strengthened only single warp of FRP sheet

on the full dimensions of concrete cylinders and S3 is

strengthened by double warp of FRP sheet on the full

dimensions of concrete cylinders. In SET III concrete

cylinders R2 is strengthened only single warp of FRP sheet

on the full dimensions of concrete cylinders and R3 is

strengthened by double warp of FRP sheet on the full

dimensions of concrete cylinders. The ultimate load

carrying capacity of all the concrete cylinders is given in

Tables below.

Page 5: Rehabiliation and Strengthening of Rcc Structures by Using Frp Composites

International Journal of Emerging Technology and Advanced Engineering

Website: www.ijetae.com (ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 3, Issue 10, October 2013)

265

Table 4.1

Results for M-15 grade of concrete in Case -I

Sr.

No.

Date of

casting

Grade of

Concrete

Date of

Test

Cylinder

Status

Breaking

Load (MT)

Strength

Kg/cm2

Remark

1. 15/06/2013 M-15 12/07/2013 Without

warp

35.75 202.40 Initial stage

2. 15/06/2013 M-15 12/07/2013 Single

warp

55.45 313.94 Increased by

55% from

initial stage

3. 15/06/2013 M-15 12/07/2013 Double

warp

77 435.95 Increased by

38.86% from

single warp

Table 4.2

Results for M-20 grade of concrete in Case -I

Sr.

No.

Date of

casting

Grade of

Concrete

Date of

Test

Cylinder

Status

Breaking

Load (MT)

Strength

Kg/cm2

Remark

1. 16/06/2013 M-20 13/07/2013 Without

warp

45.75 259 Initial stage

2. 16/06/2013 M-20 13/07/2013 Single

warp

65.45 370.55 Increased by

43% from

initial stage

3. 16/06/2013 M-20 13/07/2013 Double

warp

87 492.56 Increased by

33% from

single warp

Page 6: Rehabiliation and Strengthening of Rcc Structures by Using Frp Composites

International Journal of Emerging Technology and Advanced Engineering

Website: www.ijetae.com (ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 3, Issue 10, October 2013)

266

Table 4.3

Results for M-25 grade of concrete in Case –I

Sr.

No.

Date of

casting

Grade of

Concrete

Date of

Test

Cylinder

Status

Breaking

Load (MT)

Strength

Kg/cm2

Remark

1. 17/06/2013 M-25 14/07/2013 Without

warp

52.45 296.95 Initial stage

2. 17/06/2013 M-25 14/07/2013 Single

warp

69.23 391.96 Increased by

32% from

initial stage

3. 17/06/2013 M-25 14/07/2013 Double

warp

98.76 559.15 Increased by

43% from

single warp

Table 4.4

Results for M-15 grade of concrete in Case –II

Sr.

No.

Date of

casting

Grade of

Concrete

Date of

Test

Cylinder

Status

Breaking

Load (MT)

Strength

Kg/cm2

Remark

1. 18/06/2013 M-15 15/07/2013 Without

warp

34.85 197.31 Initial stage

2. 18/06/2013 M-15 15/07/2013 Single

warp

56.24 318.41 Increased by

61% from

initial stage

3. 18/06/2013 M-15 15/07/2013 Double

warp

76.85 435.10 Increased by

36% from

single warp

Page 7: Rehabiliation and Strengthening of Rcc Structures by Using Frp Composites

International Journal of Emerging Technology and Advanced Engineering

Website: www.ijetae.com (ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 3, Issue 10, October 2013)

267

Table 4.5

Results for M-20 grade of concrete in Case –II

Sr.

No.

Date of

casting

Grade of

Concrete

Date of

Test

Cylinder

Status

Breaking

Load (MT)

Strength

Kg/cm2

Remark

1. 19/07/2013 M-20 16/08/2013 Without

warp

45.20 255.90 Initial stage

2. 19/07/2013 M-20 16/08/2013 Single

warp

64.84 367.10 Increased by

43.45% from

initial stage

3. 19/07/2013 M-20 16/08/2013 Double

warp

85.88 486.22 Increased by

32% from

single warp

Table 4.6

Results for M-25 grade of concrete in Case –II

Sr.

No.

Date of

casting

Grade of

Concrete

Date of

Test

Cylinder

Status

Breaking

Load (MT)

Strength

Kg/cm2

Remark

1. 20/07/2013 M-25 17/08/2013 Without

warp

51.25 290.16 Initial stage

2. 20/07/2013 M-25 17/08/2013 Single

warp

68.88 389.97 Increased by

34.39% from

initial stage

3. 20/07/2013 M-25 17/08/2013 Double

warp

97.95 554.56 Increased by

42.2% from

single warp

Page 8: Rehabiliation and Strengthening of Rcc Structures by Using Frp Composites

International Journal of Emerging Technology and Advanced Engineering

Website: www.ijetae.com (ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 3, Issue 10, October 2013)

268

Table 4.7

Results for M-15 grade of concrete in Case –III

Table 4.8

Results for M-20 grade of concrete in Case –III

Sr.

No.

Date of

casting

Grade of

Concrete

Date of

Test

Cylinder

Status

Breaking

Load (MT)

Strength

Kg/cm2

Remark

1. 24/06/2013 M-15 14/07/2013 Without

warp

35.05 198.44 Initial stage

2. 24/06/2013 M-15 14/07/2013 Single

warp

56.29 318.69 Increased by

60% from initial

stage

3. 24/06/2013 M-15 14/07/2013 Double

warp

76.15 431.13 Increased by

36.64% from

single warp

Sr.

No.

Date of

casting

Grade of

Concrete

Date of

Test

Cylinder

Status

Breaking

Load (MT)

Strength

Kg/cm2

Remark

1. 26/07/2013 M-20 15/08/2013 Without

warp

44.89 254.15 Initial stage

2. 26/07/2013 M-20 15/08/2013 Single

warp

64.56 365.52 Increased by

43.38% from

initial stage

3. 26/07/2013 M-20 15/08/2013 Double

warp

85.42 483.62 Increased by

32.31% from

single warp

Page 9: Rehabiliation and Strengthening of Rcc Structures by Using Frp Composites

International Journal of Emerging Technology and Advanced Engineering

Website: www.ijetae.com (ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 3, Issue 10, October 2013)

269

Table 4.9

Results for M-25 grade of concrete in Case –III

Table 4.10

Results for M-15 grade of concrete in Case –IV

Sr.

No.

Date of

casting

Grade of

Concrete

Date of

Test

Cylinder

Status

Breaking

Load (MT)

Strength

Kg/cm2

Remark

1. 27/07/2013 M-15 16/08/2013 Without

warp

35.19 199.23 Initial stage

2. 27/07/2013 M-15 16/08/2013 Single

warp

57.05 323 Increased by

62.12% from

initial stage

3. 27/07/2013 M-15 16/08/2013 Double

warp

76.45 432.83 Increased by

34% from

single warp

Sr.

No.

Date of

casting

Grade of

Concrete

Date of

Test

Cylinder

Status

Breaking

Load (MT)

Strength

Kg/cm2

Remark

1. 26/07/2013 M-25 15/08/2013 Without

warp

50.85 287.89 Initial stage

2. 26/07/2013 M-25 15/08/2013 Single

warp

67.28 380.92 Increased by

32.31% from

initial stage

3. 26/07/2013 M-25 15/08/2013 Double

warp

96.70 547.48 Increased by

43.72% from

single warp

Page 10: Rehabiliation and Strengthening of Rcc Structures by Using Frp Composites

International Journal of Emerging Technology and Advanced Engineering

Website: www.ijetae.com (ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 3, Issue 10, October 2013)

270

Table 4.11

Results for M-20 grade of concrete in Case –IV

Sr.

No.

Date of

casting

Grade of

Concrete

Date of

Test

Cylinder

Status

Breaking

Load (MT)

Strength

Kg/cm2

Remark

1. 28/07/2013 M-20 17/08/2013 Without

warp

45.10 255.34 Initial stage

2. 28/07/2013 M-20 17/08/2013 Single

warp

64.95 367.72 Increased by

44.01% from

initial stage

3. 28/07/2013 M-20 17/08/2013 Double

warp

85.92 486.45 Increased by

32.2% from

single warp

Table 4.12

Results for M-25 grade of concrete in Case –IV

Sr.

No.

Date of

casting

Grade of

Concrete

Date of

Test

Cylinder

Status

Breaking

Load (MT)

Strength

Kg/cm2

Remark

1. 28/07/2013 M-25 17/08/2013 Without

warp

51.25 290.16 Initial stage

2. 28/07/2013 M-25 17/08/2013 Single

warp

68.15 385.84 Increased by

32.97% from

initial stage

3. 28/07/2013 M-25 17/08/2013 Double

warp

96.25 544.93 Increased by

41.23% from

single warp

Page 11: Rehabiliation and Strengthening of Rcc Structures by Using Frp Composites

International Journal of Emerging Technology and Advanced Engineering

Website: www.ijetae.com (ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 3, Issue 10, October 2013)

271

Fig – 4.1 Combined results for breaking load on grades case-I

Fig – 4.2 Combined results for breaking load on grades case-II

Page 12: Rehabiliation and Strengthening of Rcc Structures by Using Frp Composites

International Journal of Emerging Technology and Advanced Engineering

Website: www.ijetae.com (ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 3, Issue 10, October 2013)

272

Fig – 4.3 Combined results for breaking load on grades case-III

Fig – 4.4 Combined result for breaking load on grades case-IV

Page 13: Rehabiliation and Strengthening of Rcc Structures by Using Frp Composites

International Journal of Emerging Technology and Advanced Engineering

Website: www.ijetae.com (ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 3, Issue 10, October 2013)

273

V. CONCLUSION

All specimens are tested At Gov. Engineering College

Civil Laboratory, SAGAR. The results of testing on

cylinders are given above in tables. In this exercise we have

chosen three grades of concrete cylinders M-15, M-20 and

M-25 which are generally used in these days for

construction work under the limit state design consideration.

Test Cylinders Size 150 mm diameter x 300 mm height

water cured. Date of Wrapping is 36 hrs before from date of

testing. We have made 3specimens for each grade and tests

are applied on all 9 specimens. In this study the specimens

are made by concrete and warp with the FRP (Fibre-

reinforced plastic). The tests are conducted on normal

concrete and FRP warped concrete. After completing all the

analysis on normal concrete and FRP warped concrete

grades M-15, M-20 and M-25, the strength of concrete grade

is increased with average 37% for all grades.

REFERENCES

[1] M. A. Shahawy, M. Arockiasamy, T. Beitelman, R. Sowrirajan

“Reinforced concrete rectangular beams strengthened with CFRP

laminates” Composites: Part B 27B (1996) 225-233.

[2] Victor N. Kaliakin, Michael J. Chajes and Ted F. Januszka “Analysis

of concrete beams reinforced with externally bonded woven

composite fabrics” Composites: Part B 27B (1996) 235-244.

[3] 3. Koji Takeda, Yoshiyuki Mitsui, Kiyoshi Murakami, Hiromichi

Sakai and Moriyasu Nakamura “Flexural behaviour of reinforced concrete beams strengthened with carbon fibre sheets” Composites

Part A 27A (1996) 981-987.

[4] G. Spadea, F. Bencardino and R. N. Swamy “Structural Behavior of Composite RC Beams with Externally Bonded CFRP” Journal of

Composites for Construction Vol. 2, No. 3. August, 1998. 132-137.

[5] Ahmed Khalifa, William J. Gold, Antonio Nanni, and Abdel Aziz

M.I. “Contribution of externally bonded FRP to shear capacity of RC

flexural members” Journal of Composites for Construction, Vol. 2. No. 4, November, 1998. 195-202.

[6] N. F. Grace, G. A. Sayed, A. K. Soliman and K. R. Saleh “Strengthening Reinforced Concrete Beams Using Fiber Reinforced

Polymer (FRP) Laminates” ACI Structural Journal/September-

October 1999. 865-875.

[7] B. Taljsten and L. Elfgren “Strengthening concrete beams for shear

using CFRP- materials: evaluation of different application methods”

Composites: Part B 31 (2000) 87-96.

[8] Ahmed Khalifa, Antonio Nanni “Improving shear capacity of existing RC T-section beams using CFRP composites” Cement & Concrete

Composites 22 (2000) 165-174.

[9] Thanasis C. Triantafillou and Costas P. Antonopoulos “Design of concrete flexural members strengthened in shear with FRP” Journal of

Composites for Construction, Vol. 4, No. 4, November, 2000. 198-

205.

[10] V.P.V. Ramana, T. Kant, S.E. Morton, P.K. Dutta, A. Mukherjee and

Y.M. Desai “Behavior of CFRPC strengthened reinforced concrete beams with varying degrees of strengthening” Composites: Part B 31

(2000) 461-470.

[11] D. Kachlakev and D.D. McCurry “Behavior of full-scale reinforced

concrete beams retrofitted for shear and flexural with FRP laminates”

Composites: Part B 31 (2000) 445-452.

[12] Alex Li, Cheikhna Diagana, Yves Delmas “CRFP contribution to

shear capacity of strengthened RC beams” Engineering Structures 23

(2001) 1212-1220.

[13] J. F. Bonacci and M. Maalej “Behavioral trends of RC beams

strengthened with externally bonded FRP” Journal of Composites for Construction, Vol. 5, No.2, May, 2001, 102-113.

[14] Ahmed Khalifa, Antonio Nanni “Rehabilitation of rectangular simply

supported RC beams with shear deficiencies using CFRP composites” Construction and Building Materials 16 (2002) 135-146.

[15] Bjorn Taljsten “Strengthening concrete beams for shear with CFRP sheets” Construction and Building Materials 17 (2003) 15-26.

[16] C. Diagana, A.Li, B. Gedalia, Y. Delmas “Shear strengthening

effectiveness with CFF strips” Engineering Structures 25 (2003) 507-516.

[17] M.N.S. Hadi “Retrofitting of shear failed reinforced concrete beams” Composite Structures 62 (2003) 1-6.

[18] Sergio F. Brena, Regan M. Bramblett, Sharon L. Wood, and Michael

E. Kreger “Increasing Flexural Capacity of Reinforced Concrete Beams Using Carbon Fiber-Reinforced Polymer Composites” ACI

Structural Journal/January-February 2003. 36-46.

[19] Bimal Babu Adhikary, Hiroshi Mutsuyoshi, and Muhammad

Ashraf “ShearStrengthening of Reinforced Concrete Beams Using

Fiber-Reinforced Polymer Sheets with Bonded Anchorage” ACI Structural Journal/September-October 2004. 660-668.

[20] Zhichao Zhang and Cheng-Tzu Thomas Hsu “Shear Strengthening of Reinforced Concrete Beams Using Carbon-Fiber-Reinforced Polymer

Laminates” Journal of Composites for Construction, Vol. 9, No.2,

April 1, 2005. 158-169.