reducing the delay: can a rapid hiv test discriminate false positives as effectively as a western...

1
Reducing the Delay: Can a Rapid HIV Test Reducing the Delay: Can a Rapid HIV Test Discriminate False Positives as Effectively as a Discriminate False Positives as Effectively as a Western Blot – the NJ Experience Western Blot – the NJ Experience Eugene G. Martin, Ph.D. * , Gratian Salaru, M.D. * , Kenneth Earley * * , Phil Bruccoleri * * , Sindy M. Paul, M.D., M.P.H. * * , and Evan M. Cadoff, M.D. * UMDNJ – Robert Wood Johnson Medical School * and New Jersey Department of Health and Human Services * * CONCLUSION: A rapid, alternative confirmatory algorithm has been used to retrospectively confirm all Oraquick® HIV positive tests in New Jersey over a ten month period. • A waived algorithm based upon initial Oraquick® HIV screening and confirmatory testing by Trinity Unigold™ Recombigen confirmed all Western Blot positive specimens while excluding all false positives identified by the initial Oraquick® screen. • A rapid testing strategy that provides a complete answer in a single visit would allow Counseling and Testing personnel to more effectively guide HIV + Results Issues/Background Concerns about the significance of false-positive results in low- prevalence populations led the US Public Health Service to utilize a sequential, two-test algorithm (EIA followed by a Western Blot) to confirm initially reactive rapid HIV results. Confirmation of preliminary positives by Western Blot is time- consuming, complex and labor intensive. Clients often wait 48-96 hours before receiving a confirmed result, experience enormous anxiety and many fail to return for follow-up. • Among HIV EIA screen positive blood donors 4.8% have false positive Western Blots. 1 Prior to rapid testing approximately 35% of all patients visiting NJ Counseling and Testing Sites (CTS) for HIV testing failed to receive their results, because they failed to return for a follow-up THE PROBLEM – The Second Visit Methods: • Retrospective study using all residual specimens sent to NJ Public Health and Environmental Labs for HIV confirmatory testing. • Utilizing the Western Blot serum samples available on 8 of 10 discordants, alternative rapid HIV tests were performed: (BioRad Multispot®, MedMira Reveal®, and Trinity Uni-Gold™) to see whether a second, rapid HIV could effectively identify a discordant specimen. Residual specimens from 363 Western Blot confirmatory specimens were retrospectively tested with alternative rapid HIV tests: (BioRad Multispot®, MedMira Reveal®, and Trinity Uni-Gold™) to see whether a second, rapid HIV could confirm a preliminary positive HIV specimen. Results Results IDENTIFICATION OF FALSE POSITIVES OraQuick® testing was reproducible in 7 of 8 available serum discordant specimens . •Two of three alternative rapid tests (Uni-Gold® and Reveal®) TOTAL TESTS 7/1/04 – 4/19/05 HIV PRELIM POSITIV E WESTERN BLOT – Discordants 15,923 363 (2.3 %) 10 (3.4% of Prelim Pos. – 0.07% Overall) 0.0% 0.5% 1.0% 1.5% 2.0% 2.5% 3.0% 3.5% 4.0% 4.5% 5.0% Year P revalence 0 5000 10000 15000 20000 25000 30000 35000 U tilization P revalence U tilization HIV Testing in New Jersey 326 244 82 47 11 0 50 100 150 200 250 300 350 Num ber D isposition ofC onfirm ed H IV + C lients Confirm ed HIV + Result retuned to client Did Not Receive Results Referred to NAP Found by NAP 1 Kleinman S, Busch MP, Hall L, et al. False- positive HIV-1 test results in a low-risk screening setting of voluntary blood donation. JAMA. 1998;280:1080-1085. RETURN FOR RESULTS: Of 326 Western Blot Confirmed Positive HIV results, 82 (25.2%) failed to return and were not initially notified of their HIV status. Forty seven were referred to the Notification Assistance Program (NAP). Eleven (23.4%) of those referred to the NAP were eventually located after varying periods of delay. Seventy-one (71) HIV + clients were never contacted regarding their final HIV status. PROPOSED SOLUTION: CONFIRM A RAPID HIV RESULT WITH A SECONDARY RAPID HIV TEST AT THE TIME OF THE INITIAL SCREENING THE ISSUES: Will it detect False Positives as successfully as the Western Blot? Will it confirm True Positives as effectively as the Western Blot? Oraquick Introduction Confirmatory test results 8 Western Blot negative (False Positive OraQuick) 355 Western Blot positive (True Positive OraQuick) OraSure OraQuick 7 positive 1 negative 355 positive Trinity Uni-Gold 8 negative 355 positive BioRad Multispot 7 negative 1 positive 354 positive 1 QNS MedMira Reveal 8 negative 340 positive 15 sample interference Follow-up of >2 months 6/6 negative Western Blot 6/6 negative viral load Trinity Uni-Gold Bio-Rad Multispot MedMira Reveal Orasure Oraquick N egative D iscordant W B Pos 363 PRELIM POS 10 DISCORDANT 15,570 NEGATIVE NJ 2004 RAPID HIV TESTING

Upload: britney-sullivan

Post on 30-Dec-2015

212 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Reducing the Delay: Can a Rapid HIV Test Discriminate False Positives as Effectively as a Western Blot – the NJ Experience Eugene G. Martin, Ph.D. *, Gratian

Reducing the Delay: Can a Rapid HIV Test Discriminate False Reducing the Delay: Can a Rapid HIV Test Discriminate False Positives as Effectively as a Western Blot – the NJ Experience Positives as Effectively as a Western Blot – the NJ Experience

Eugene G. Martin, Ph.D.*, Gratian Salaru, M.D.* , Kenneth Earley * *, Phil Bruccoleri* * , Sindy M. Paul, M.D., M.P.H.* *, and Evan M. Cadoff, M.D.*

UMDNJ – Robert Wood Johnson Medical School * andNew Jersey Department of Health and Human Services * *

CONCLUSION:

• A rapid, alternative confirmatory algorithm has been used to retrospectively confirm all Oraquick® HIV positive tests in New Jersey over a ten month period.

• A waived algorithm based upon initial Oraquick® HIV screening and confirmatory testing by Trinity Unigold™ Recombigen confirmed all Western Blot positive specimens while excluding all false positives identified by the initial Oraquick® screen.

• A rapid testing strategy that provides a complete answer in a single visit would allow Counseling and Testing personnel to more effectively guide HIV + patients into treatment, while avoiding the nearly 25% of HIV + clients who are lost to follow-up.

ResultsIssues/Background

• Concerns about the significance of false-positive results in low-prevalence populations led the US Public Health Service to utilize a sequential, two-test algorithm (EIA followed by a Western Blot) to confirm initially reactive rapid HIV results.

• Confirmation of preliminary positives by Western Blot is time-consuming, complex and labor intensive. Clients often wait 48-96 hours before receiving a confirmed result, experience enormous anxiety and many fail to return for follow-up.

• Among HIV EIA screen positive blood donors 4.8% have false positive Western Blots.1

• Prior to rapid testing approximately 35% of all patients visiting NJ Counseling and Testing Sites (CTS) for HIV testing failed to receive their results, because they failed to return for a follow-up visit.

•Currently, more than 97 % of tested clients receive negative results at their initial visit, but 35% of clients who need to return for HIV confirmation still fail to return and may not be referred for treatment..

.

THE PROBLEM – The Second Visit Methods:

• Retrospective study using all residual specimens sent to NJ Public Health and Environmental Labs for HIV confirmatory testing.

• Utilizing the Western Blot serum samples available on 8 of 10 discordants, alternative rapid HIV tests were performed: (BioRad Multispot®, MedMira Reveal®, and Trinity Uni-Gold™) to see whether a second, rapid HIV could effectively identify a discordant specimen.

• Residual specimens from 363 Western Blot confirmatory specimens were retrospectively tested with alternative rapid HIV tests: (BioRad Multispot®, MedMira Reveal®, and Trinity Uni-Gold™) to see whether a second, rapid HIV could confirm a preliminary positive HIV specimen.

ResultsResults

• IDENTIFICATION OF FALSE POSITIVES

• OraQuick® testing was reproducible in 7 of 8 available serum discordant specimens .

•Two of three alternative rapid tests (Uni-Gold® and Reveal®) successfully identified all 8 available discordant specimens as non-reactive.

• The Multispot® assay correctly identified 7 of 8 samples as negative with one specimen demonstrating operator-dependent results.

TOTAL TESTS 7/1/04 – 4/19/05

HIV PRELIM POSITIVE

WESTERN BLOT –Discordants

15,923 363 (2.3 %) 10 (3.4% of Prelim Pos. – 0.07% Overall)

0.0%0.5%1.0%1.5%2.0%2.5%3.0%3.5%4.0%4.5%5.0%

Year

Pre

vale

nce

0

5000

10000

15000

20000

25000

30000

35000

Uti

liza

tio

n

Prevalence

Utilization

HIV Testing in New Jersey

326

244

82

47

11

0

50

100

150

200

250

300

350

Number

Disposition of Confirmed HIV + Clients

Confirmed HIV + Result retuned to client Did Not Receive ResultsReferred to NAP Found by NAP

1 Kleinman S, Busch MP, Hall L, et al. False-positive HIV-1 test results in a low-risk screening setting of voluntary blood donation. JAMA. 1998;280:1080-1085.

RETURN FOR RESULTS:Of 326 Western Blot Confirmed Positive HIV results, 82 (25.2%) failed to return and were not initially notified of their HIV status. Forty seven were referred to the Notification Assistance Program (NAP). Eleven (23.4%) of those referred to the NAP were eventually located after varying periods of delay. Seventy-one (71) HIV + clients were never contacted regarding their final HIV status.

PROPOSED SOLUTION:

CONFIRM A RAPID HIV RESULT WITH A SECONDARY RAPID HIV TEST AT THE TIME OF THE INITIAL SCREENING

THE ISSUES:

• Will it detect False Positives as successfully as the Western Blot?

• Will it confirm True Positives as effectively as the Western Blot?

Oraquick Introduction

Confirmatory test results

8 Western Blot negative

(False Positive OraQuick)

355 Western Blot positive

(True Positive OraQuick)

OraSure OraQuick 7 positive1 negative

355 positive

Trinity Uni-Gold 8 negative 355 positive

BioRad Multispot 7 negative1 positive

354 positive1 QNS

MedMira Reveal 8 negative 340 positive15 sample interference

Follow-up of >2 months

6/6 negative Western Blot6/6 negative viral load

Trinity Uni-GoldBio-Rad MultispotMedMira Reveal

Orasure Oraquick

Negative Discordant WB Pos

363PRELIM POS

10 DISCORDANT

15,570NEGATIVE

NJ 2004 R

APID

HIV TESTIN

G