reduce energy costs and environmental impact

2
REDUCE YOUR ENERGY COSTS PM GROUP EXPERIENCE Our experience has been garnered from working with leading multinational clients in many business sectors over three decades. We bring international best practice in our approach to energy optimisation. We can assemble the right team to reduce the energy consumption of your project. Key Services n Sustainability Assessments (LEED, BREEAM) n Building Energy Simulation Studies n Process Energy Simulation Studies n Renewable Energy Feasibility Studies n EED Methodology Facilitation. We can assist you to address energy usage in a holistic and systematic way to improve your competitiveness and ensure a sustainable energy future. We have a team of world- class experts in a variety of engineering and scientific disciplines focused on energy efficiency. AND ENVIRONMENTAL IMPACT RECENT VIABLE ENERGY SAVINGS IDENTIFIED FOR OUR CLIENTS n Biotech manufacturer - 40% saving on group-wide internal benchmark n Food manufacturer - 24% saving on a 2 million total energy bill n Technology sector client - 18% saving on a 1.9 million total energy bill. CON LEDDY Associate Director Group Leader, Sustainable Energy Engineering MICHAEL LAW Associate Director Clean Utility and Process Specialist OUR ENERGY SPECIALISTS To find out how we can assist you with your energy requirements, please contact CON LEDDY +353 21 435 8922 [email protected] OR MICHAEL HOYNE +353 1 404 0700 [email protected] MICHAEL HOYNE IS393 Technical Assessor and Renewable Energy specialist RICHARD COFFEY Energy Auditor and Process Engineering Specialist VINCENT CRONIN Energy Efficient Lighting Specialist LIAM CROWE Utility and Refrigeration Systems Specialist DARRAGH CONWAY LEAN/Six Sigma Blackbelt www.pmgroup-global.com Europe // Asia // USA PAT SWORDS Associate Director CHP Specialist MICHAEL KEOHANE Energy Profiling Analyst and Renewable Energy Specialist MIKE CLUCAS Process Specialist

Upload: pm-group

Post on 23-Mar-2016

222 views

Category:

Documents


3 download

DESCRIPTION

PM Group can assist you to address energy usage in a holistic and systematic way to improve your competitiveness and ensure a sustainable energy future. We have a team of worldclass experts in a variety of engineering and scientific disciplines focused on energy efficiency.

TRANSCRIPT

REDUCE YOUR ENERGY

COSTS

PM GROUP EXPERIENCEOur experience has been garnered from working with leading multinational clients in many business sectors over three decades. We bring international best practice in our approach to energy optimisation. We can assemble the right team to reduce the energy consumption of your project.

Key Services n Sustainability Assessments (LEED, BREEAM)

n Building Energy Simulation Studies

n Process Energy Simulation Studies

n Renewable Energy Feasibility Studies

n EED Methodology Facilitation.

We can assist you to address energy usage in a holistic and systematic way to improve your competitiveness and ensure a sustainable energy future.

We have a team of world-class experts in a variety of engineering and scientific disciplines focused on energy efficiency.

AND ENVIRONMENTAL IMPACT

RECENT VIABLE ENERGY SAVINGS IDENTIFIED FOR OUR CLIENTS

n Biotech manufacturer - 40% saving on group-wide internal benchmark

n Food manufacturer - 24% saving on a €2 million total energy bill

n Technology sector client - 18% saving on a €1.9 million total energy bill.

CON LEddy Associate DirectorGroup Leader, Sustainable Energy Engineering

MIChaEL LawAssociate DirectorClean Utility and Process Specialist

OUR EnERGy

SPECIaLISTS

To find out how we can assist you with your energy requirements, please contact

CON LEddy+353 21 435 [email protected] MIChaEL hOyNE+353 1 404 [email protected]

MIChaEL hOyNE IS393 Technical Assessor and Renewable Energy specialist

RIChaRd COFFEyEnergy Auditor and Process Engineering Specialist

VINCENT CRONINEnergy Efficient Lighting Specialist

LIaM CROwE Utility and Refrigeration Systems Specialist

daRRaGh CONwayLEAn/Six Sigma Blackbelt

www.pmgroup-global.comEurope // Asia // USA

PaT SwORdS Associate DirectorCHP Specialist

MIChaEL KEOhaNE Energy Profiling Analyst and Renewable Energy Specialist

MIKE CLUCaS Process Specialist

Tyndall National Institute for ICT Research

LEaN for Energy Efficiency

Our team of experts has the skills and resources to review and make recommendations on all aspects of a company’s energy usage. A key element of this involves our Lean/Six Sigma specialists who focus on how energy is used across the manufacturing process. They can work with your in-house process experts to identify potential energy savings through the use of Lean/Six Sigma tools normally associated with productivity improvements.

LEAn Services Include:n Mapping of current energy usage across a

facility and identification and metering of significant energy users across the facility

n Incorporation of all aspects of energy usage into the Value Stream Map. This will include significant energy users that are not normally associated with VSMs.

n Coordination of energy focused kaizen events aimed at optimising a particular area of energy usage

n Use of Six Sigma statistical methods to optimise process settings resulting in reduced energy consumption.

Winner: SEAI 2010 Renewable Energy Systems Award

Part of this project involved the refurbishment of existing clean-room suites. By taking a holistic view of the energy needs of both the process and facility systems, opportunities for system integration were exploited, resulting in a 28% reduction in primary energy consumption for the existing ICT facility. Measures adopted in both the existing and new facilities included:

n Reconfiguration of the chilled water system resulting in a 40% reduction in energy consumption for the same cooling capacity.

n Heat from the process cooling water is used to temper incoming air. This has the added benefit of reducing the load on chillers.

n A heat pump is used to efficiently remove heat from a large cluster of computer servers and transfer it at higher temperatures to the reheat coils controlling the temperature in each laboratory (COP = 9).

Energy Efficiency and Greenhouse Gas Emissions Benchmarking Study The Singapore Ministry of Environment and Water Resources (MEWR) commissioned PM Group to conduct an International exercise to benchmark the performance of Singapore’s Pharmaceutical and nutritional plants against equivalent facilities around the world. The focus of the benchmarking study related to Energy Efficiency and Greenhouse Gas Emissions.

The project culminated in the delivery of a series of reports including:

n Energy assessment framework n Site benchmarking reports n Common assessment framework n Best practice guide n Government initiatives review

winner: ISPE Facility of the year 2009 (Sustainability Category)

This project involved the development of a greenfield biopharmaceutical manufacturing facility for Centocor (now named Janssen Biologics) in Cork, Ireland. The project team worked closely with local residents to mitigate the impact of this large, complex project on the community. The project utilized advanced membrane waste water treatment, captured rainwater for recycling, and installed a biomass (woodchip) boiler for base steam load.

This project also involved extensive landscaping that included planting 70,000 trees to mitigate visual impact. The building is 40% more energy-efficient than internal benchmark biotech facilities and there was a 90% reduction in the carbon footprint versus fossil fuel.

Minimising Energy Consumption for our Clients

UCC Western Gateway Building

Janssen Biologics

winner: CIBSE Ireland Sustainable design and Research award in 2011

This 25,000sqm facility provides research and teaching accommodation for a range of academic departments at the university.

RENEwaBLE aNd ALTERNATIVE ENERGYPM Group has extensive experience in feasibility studies and engineering design for renewable energy solutions that best fit your energy profile. We can provide independent advice on the important issues for these projects, including grant supports, ESCo model, fuel supply and storage options.

UCC Western Gateway Energy Consumption

Key Featuresn VAV underfloor system in conjunction with high

temperature cooling system significantly reduces energy usage

n Use of demand controlled ventilation(DCV) to match variable occupancy

n Low specific fan power (SFP)n Thermal wheels for high heat recovery efficiency.n 1 MW simultaneous heating and cooling heat

pump using ground water as heat sink and source

n Ground water also provides free coolingn Excellent part load efficiency with scope for

future expansion

0.0

50.0

100.0

150.0

200.0

250.0

300.0

350.0

400.0

450.0 Total Electricity

Total Fossil Fuel (Thermal)

GoodPractice

TypicalTypical WGB Actual Energy Use

(Metered or Billed)CIBSE TM: 46

University Campus

ECON 19 Type 2 Naturally Ventilated

kWhr

/m2

Janssen Biologics