recuperator de caldura-tangra-evb-pp-04-v-fisa_tehnica.pdf

Upload: dana-lore

Post on 04-Jun-2018

305 views

Category:

Documents


1 download

TRANSCRIPT

  • 8/14/2019 RECUPERATOR DE CALDURA-Tangra-EVB-PP-04-V-Fisa_Tehnica.pdf

    1/12

    TECHNICAL CATALOGUE

    Save energy!

    Reduce your costs!

    Take care of the environment!

    HEAT RECOVERY UNITS

  • 8/14/2019 RECUPERATOR DE CALDURA-Tangra-EVB-PP-04-V-Fisa_Tehnica.pdf

    2/12

    The air we breathe is important for our life!

    One can live 3 weeks without food, 3 days without water, 3 minutes without air!

    People in industrialized countries spend indoor, on average about 90% of the year. Modern buildings and systems do not

    allow natural ventilation. This is a major precondition for creation of mechanical ventilation.

    The fresh air must be heated in winter and chilled in

    summer, and this is related with significant energy

    costs. There is a preliminary trend for growing of the

    price of energy resources for the last 10 years:

    Energy consumption leads to environmental pollution and exhausting of resources of the

    planet. It is our duty to protect it for future generation.

    Quickly return on investments using heat recovery systems:

    Human health and productivity are closely connected with the air quality. Our children

    need fresh air even more than us it could help to avoid illnesses and allergies.

    The data shown are not universal. These parameters are valid

    for the following conditions:

    - Bulgaria, Sofia;

    - Indoor temperature 22oC;

    - Air flow 3000m3/h;

    - Installation working time 10 of 24h.

    - Installation life time 10 years;

    - Energy price 0.1 Euro/kWh;

    - 8% annual maintenance costs;

    - Energy price growth 12% per year;

    - The initial expenses are average;

    Your lost money!

    HEAT RECOVERY UNITS

  • 8/14/2019 RECUPERATOR DE CALDURA-Tangra-EVB-PP-04-V-Fisa_Tehnica.pdf

    3/12

    Heat recovery systems are the proper technical and economically acceptable solution:

    Applications of heat recovery units:

    Ventilation and air-conditioning systems, which provide fresh air supply in:

    - Office and residential buildings;

    - Hotels, restaurants, cafes, nightclubs;

    - Sports halls, gyms and swimming pools;

    - Hospitals, schools, laboratories;

    - Cinemas, theaters, concert halls;

    - Food industries bakeries;

    - Technological systems;- Industrial ventilation.

    0

    1000

    2000

    3000

    4000

    5000

    6000

    7000

    8000

    9000

    10000

    -15 -10 -5 0 5 10

    Q ,kWh

    text ,

    ENERGY CONSUMPTION PER YEAR, kWh

    AHU - A

    0

    1000

    2000

    3000

    4000

    5000

    6000

    7000

    8000

    9000

    10000

    -15 -10 -5 0 5 10

    Q ,kWh

    text ,

    ENERGY CONSUMPTION PER YEAR, kWh

    AHU - A

    AHU - B

    0

    1000

    2000

    3000

    4000

    5000

    6000

    7000

    8000

    9000

    10000

    -15 -10 -5 0 5 10

    Q ,kWh

    text ,

    ENERGY CONSUMPTION PER YEAR, kWh

    AHU - A

    AHU - C

    0

    1000

    2000

    3000

    4000

    5000

    6000

    7000

    8000

    9000

    10000

    -15 -10 -5 0 5 10

    Q ,kWh

    text ,

    ENERGY CONSUMPTION PER YEAR, kWh

    AHU - A

    AHU - D

    ,

    ,

    AHU - A

    RECAHU - B

    AHU - C REC REC

    AHU - D

    System without

    recuperation

    E=0%

    System with plate

    heat exchanger

    E=45 58%

    System with high-

    efficiency plate heat

    exchanger

    E=65 70%

    System with rotary

    heat exchanger

    E=70 83%

    E - % percentage of recovered energy

    HEAT RECOVERY UNITS

  • 8/14/2019 RECUPERATOR DE CALDURA-Tangra-EVB-PP-04-V-Fisa_Tehnica.pdf

    4/12

    HEAT RECOVERY UNITS 05.01-01EVB AL

    EVB AL HEAT RECOVERY UNITS

    Description

    Units for secondary use of energy of the exhaust air in

    ventilation and air-conditioning systems.

    Operation temperatures from -20C to +50C.

    Designed to work with clean air in non-aggressive and

    explosion-proof environment

    Construction

    Supporting construction, made by anodized aluminum

    profiles.

    Thermo and sound insulated panels, powder coated

    RAL7035

    - Internal insulation Firex 10 mm, fire resistance class:

    0-BS 476 Part 6; class 1 BS 476 Part7;

    - Sandwich panels 25 mm with XPS insulation class M1

    or fiberglass class M0;

    Cross ow aluminum plate heat exchanger with ecien-

    cy up to 55%;

    Double inlet direct drive centrifugal fans 230V, 50Hz, IP

    20 (higher protection on request);

    Air lters class G4 EN 779:2002;

    Rectangular or round duct connector;

    Drain tray with connection;

    Conguration allows easily modifying position of the l-

    ters, fans and duct connectors;

    Service doors from the bottom and from the side;

    By-pass with multiple leaf damper;

    Heating/ cooling coil on request;

    Hanging support or basic steps on request;

    Roof panel for outdoor installation on request.

    Control and management systems - see section 7

  • 8/14/2019 RECUPERATOR DE CALDURA-Tangra-EVB-PP-04-V-Fisa_Tehnica.pdf

    5/12

    05.01-02 HEAT RECOVERY UNITSEVB AL

    Overall and joined dimensions

    EVB AL, H Horizontal installation

    ModelMax. air flow

    [m3/h]

    [mm]

    [mm]

    L

    [mm]

    Hmax

    [mm]

    C

    [mm]

    D

    [mm]

    [mm]

    G

    [mm]

    I

    [mm]

    VB PP-04-H 500 800 280 800 320 215 150 200 215 150

    VB AL-06-H 700 1000 350 1000 390 225 180 250 225 180

    VB AL-10-H 1000 1000 420 1300 460 235 210 280 300 250

    VB AL-20-H 2200 1060 480 1500 520 300 260 315 300 300

    VB AL-30-H 3000 1200 580 1600 620 265 290 355 400 300

    VB AL-35-H 3500 1200 680 1600 720 335 290 355 400 400

    VB AL-45-H 4500 1300 900 2000 940 335 290 355 400 400

    EVB AL, V Vertical installation

    ModelMax. air flow

    [m3/h]

    [mm]

    [mm]

    L

    [mm]

    Bmax

    [mm]

    C

    [mm]

    D

    [mm]

    [mm]

    G

    [mm]

    I

    [mm]

    K

    [mm]

    VB PP-04-V 500 280 800 800 320 150 150 200 215 150 45

    VB AL-06-V 700 350 1000 1000 390 180 225 250 225 180 50

    VB AL-10-V 1000 420 1000 1300 460 210 235 280 250 300 85

    VB AL-20-V 2200 510 1060 1500 550 260 300 315 300 300 105VB AL-30V 3000 580 1200 1600 620 290 265 355 300 400 90

    VB AL-35-V 3500 680 1200 1600 620 290 335 355 400 400 140

    VB AL-45-V 4500 900 1300 2000 940 290 335 355 400 400 250

  • 8/14/2019 RECUPERATOR DE CALDURA-Tangra-EVB-PP-04-V-Fisa_Tehnica.pdf

    6/12

    7

    HEAT RECOVERY UNITS 05.01-03EVB AL

    Overall and joined dimensions

    EVB AL-BS (with by pass), H Horizontal installation

    Model [mm] [mm] L [mm] Hmax[mm] C [mm] D [mm] [mm] G [mm] I [mm]VB AL-06-BS 1050 450 1200 520 225 180 250 225 180

    VB AL-10-BS 1050 520 1300 590 235 210 280 300 250

    VB AL-20-BS 1060 650 1500 720 300 260 315 300 300

    VB AL-30-BS 1200 750 1600 820 265 290 355 400 300

    VB AL-35-BS 1300 850 1600 920 335 290 355 400 400

    VB AL-45-BS 1300 1150 2000 1220 335 290 355 400 400

    By-pass with internal multiple leaf damper;

    Manual control - on request;

    Belimo ON-OFF actuator standard version

  • 8/14/2019 RECUPERATOR DE CALDURA-Tangra-EVB-PP-04-V-Fisa_Tehnica.pdf

    7/12

    Overall and joined dimensions

    EVB AL-HBS (heating water coil and by pass), H Horizontal installation

    Model [mm] [mm] L [mm] Hmax[mm] C [mm] D [mm] [mm] G [mm] I [mm] d [mm]

    VB AL-06-HBS 1050 450 1600 520 225 180 250 225 180

    VB AL-10-HBS 1050 520 1600 590 235 210 280 300 250

    VB AL-20-HBS 1200 650 1900 720 300 260 315 300 300 1

    VB AL-30-HBS 1300 750 1900 820 265 290 355 400 300 1

    VB AL-35-HBS 1300 850 1900 920 335 290 355 400 400 1

    VB AL-45-HBS 1450 1150 2500 1220 335 290 355 400 400 1

    By-pass with internal multiple leaf damper;

    Manual control - on request;

    Belimo ON-OFF actuator standard version Two rows water coil Cu/Al;

    Four rows water coil (cooling) - on request.

    05.01-04 HEAT RECOVERY UNITSEVB AL

  • 8/14/2019 RECUPERATOR DE CALDURA-Tangra-EVB-PP-04-V-Fisa_Tehnica.pdf

    8/12

    HEAT RECOVERY UNITS 05.01-05EVB AL

    Technical characteristics

    Externalpressure

    [Pa]

    Air ow [m3/h]

    EVB PP-04

    Model Fan Nominal power [W] Nominal current [A]

    EVB-P-04 CBM/2-133/190-185W 2 x 185 0.8

    Air ow [m3/h]

    Exter

    nalpressure

    [Pa]

    EVB AL-06

    Model Fan Nominal power [W] Nominal current [A]

    BV AL-06 BM/2-146/180 2 220 1.01

  • 8/14/2019 RECUPERATOR DE CALDURA-Tangra-EVB-PP-04-V-Fisa_Tehnica.pdf

    9/12

    05.01-06 HEAT RECOVERY UNITSEVB AL

    Technical characteristics

    Externalpressure

    [Pa]

    Air ow [m3/h]

    EVB AL-10

    Model Fan Nominal power [W] Nominal current [A]

    BV AL-10 BM/4-180/180 2 147 1.5

    BV AL-10/3V BM/4-180/180-V 2 147 1.33

    Air ow [m3/h]

    Externalp

    ressure

    [Pa]

    EVB AL-20

    Model Fan Nominal power [W] Nominal current [A]

    BV AL-20 BM/4-240/240 2 370 4.2

    BV AL-20/3V BM/4-240/240-3V 2 370 3.8

  • 8/14/2019 RECUPERATOR DE CALDURA-Tangra-EVB-PP-04-V-Fisa_Tehnica.pdf

    10/12

    HEAT RECOVERY UNITS 05.01-07EVB AL

    Technical characteristics

    Externalpressure

    [Pa]

    Air ow [m3/h]

    EVB AL-30

    Model Fan Nominal power [W] Nominal current [A]

    BV AL-30 BM/4-270/200 2 370 4.0

    BV AL-30/3V BM/4-270/200-3V 2 370 3.0

    Air ow [m3/h]

    Externalpressure

    [Pa]

    EVB AL-35

    Model Fan Nominal power [W] Nominal current [A]BV AL-35 BM/4-270/270 2 550 6.2

  • 8/14/2019 RECUPERATOR DE CALDURA-Tangra-EVB-PP-04-V-Fisa_Tehnica.pdf

    11/12

    05.01-08 HEAT RECOVERY UNITSEVB AL

    Sound pressure level on frequency bands [dB]

    Model Hz 63 125 250 500 1000 2000 4000 8000

    EVB PP-04

    Inlet 49 54 51 50 48 52 50 41

    Outlet 47 55 56 65 68 70 66 63

    Rad. 40 45 40 41 44 43 41 34

    EVB AL-06

    Inlet 50 55 52 51 49 53 50 43

    Outlet 48 56 58 66 70 71 67 65

    Rad. 41 46 42 41 45 45 42 35

    EVB AL-10

    Inlet 46 51 56 61 56 51 47 40

    Outlet 46 53 58 65 68 67 66 58

    Rad. 47 48 49 50 38 39 34 27

    EVB AL-20

    Inlet 49 56 64 66 63 56 54 43

    Outlet 48 58 67 70 75 74 71 62

    Rad. 48 52 56 55 52 46 41 33

    EVB AL-30

    Inlet 49 56 63 66 64 57 56 45

    Outlet 48 57 65 71 75 74 72 63

    Rad. 48 52 55 54 52 45 42 32

    EVB AL-35

    Inlet 52 61 66 67 64 57 55 45

    Outlet 51 63 69 71 75 75 72 64

    Rad. 51 58 61 56 53 47 42 35

    EVB AL-45

    Inlet 52 61 66 67 64 57 55 45

    Outlet 51 63 69 71 75 75 72 64

    Rad. 45 53 55 50 47 42 38 31

    Note: Measured in free field conditions at a distance 1,5 m.

    [

    Pa]

    [m3/h]

    Note:The dotted curve refers to heat recovery unit with heat exchanger 800/600-2R

    EVB AL-45

    Model Fan Nominal power [W] Nominal current [A]

    BV AL 45 BM - 10/10 4P, 3V 2750 7,8

    Technical characteristics

  • 8/14/2019 RECUPERATOR DE CALDURA-Tangra-EVB-PP-04-V-Fisa_Tehnica.pdf

    12/12

    Accessories

    External high eciency lter F7, Pmax= 80Pa

    Sound attenuators

    External electric heater

    Roof for outdoor installation

    Flexible duct connectors

    3-way valve for water coil

    Freeze protection

    Pressure switch

    3-speed switch

    Hanging supports

    Basic steps

    Frame for outdoor installation

    Control and management systems - see section 7

    EVB AL - 30 /3V -HBS

    BS By pass; HBS heating coil and by pass

    3-speed fan

    Model

    Heat recovery unit

    Order designation

    - Main parameters

    - Optional parameters

    HEAT RECOVERY UNITS 05.01-09EVB AL

    Standard configuration

    ConfigurationAand Cas standard. Modification Band D- on customers request.

    A B

    C D

    EVB AL, H Horizontal installation

    EVB AL, V Vertical installation