real energy comes technical information from … · 2020. 3. 10. · real energy comes from...
TRANSCRIPT
-
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
TECHNICAL INFORMATIONModel XQ75E XQ100E XQ135E XQ150E XQ200E XQ250E XQ275 EU3
Rating - Prime Prime Prime Prime Prime Prime Prime
Frequency Hz 50 50 50 50 50 50 50
Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V
Power capacity1 kVA 75 100 135 150 200 250 275
kW 60 80 100 120 160 200 220
Output2 A 108 144 195 217 289 360 398
Breaker 4P A 160 160 250 250 400 400 630
Fuel tank ltr 593 766 766 766 1200 1200 668
Fuel consumption3 l/hr 18.66 23.26 20.9 23.2 31 35.2 48
Running time hr 32 33 37 33 39 34 14
Dimensions [LxWxH] mm 2900 x 1155 x 1940 3570 x 1155 x 2030 3570 x 1155 x 2030 3570 x 1155 x 2030 4250 x 1320 x 2445 4250 x 1320 x 2445 4308 x 1500 x 2421
Weight4 without fuel kg 2160 2540 2810 2810 3980 4110 4080
Weight4 with fuel kg 2750 3310 3580 3580 5140 5310 4670
Sound level5 dBA 656 666 62.8 62.8 66.2 66.9 66.5
POWER GENERATORS 75 - 275 KVA
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V
3. Fuel consumption measured at 75% load | fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50 Hz at 7m
6. Data at 100% load
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
REAL ENERGY COMES FROM ENERGYST
-
INTRODUCINGENERGYST.POWERED BYCATERPILLAR
We are Energyst CAT Rental Power When it comes to equipment hire, we are CAT rental. And if the world’s leading manufacturer of diesel and natural gas engines can trust Energyst with their reputation, it goes without saying that you can rely on us too.
CONTENTSINTRODUCINGENERGYST.POWERED BYCATERPILLAR
We are Energyst CAT Rental Power When it comes to equipment hire, we are CAT rental. And if the world’s leading manufacturer of diesel and natural gas engines can trust Energyst with their reputation, it goes without saying that you can rely on us too.
CONTENTS
POWER CAN OFTEN BE A MATTER OF LIFE AND DEATH. WHAT IS MORE, UNEXPECTED FAILURES ARE NOT JUST COSTLY IN TERMS OF YOUR FINANCES, THEY MAY ALSO DO UNTOLD DAMAGE TO YOUR REPUTATION. SO WHEN YOU NEED A POWERFUL SOLUTION THAT YOU CAN REALLY RELY ON, IT PAYS TO GET REAL ENERGY FROM ENERGYST.
Energyst CAT Rental Power is one of the leading providers of power rental solutions. As a subsidiary of Caterpillar dealers and Caterpillar Inc., our extensive range of world class rental equipment includes everything from power generators to load banks.
We are Energyst CAT Rental PowerWhen it comes to equipment hire, we are CAT rental. And if the world’s leading manufacturer of diesel and natural gas engines can trust Energyst with their reputation, it goes without saying that you can rely on us too.
OUR SOLUTIONS 3
POWER GENERATORS 4
OFFSHORE
POWER GENERATORS 7
FUEL TANKS 10
LOAD BANKS 11
TRANSFORMERS 12
-
,
REAL ENERGY COMES FROM ENERGYST
OUR SOLUTIONS
POWERSOLUTIONS
From a sudden power failure to a
planned shutdown, temporary power
for a small-scale project or a long-term
solution for a mega plant, Energyst can
help. We have a range of Caterpillar
generator sets for every power solution.
From a simple power set up to a multi-
megawatt installation, our modular
solutions work together to generate the
power you need. So if you need 500kVa,
simply rent four of our 125 kVA units.
Our power equipment includes:
• Power Generators up to 2000 kVA
• Cables
• Fuel tanks
• Distribution gear
• Load banks
• Transformers
Our knowledgeable and experienced staff are on hand to answer any questions
or provide more information about how we can help meet your specifi c needs.
INTRODUCINGENERGYST.POWERED BYCATERPILLAR
,
REAL ENERGY COMES FROM ENERGYST
OUR SOLUTIONS
POWERSOLUTIONS
From a sudden power failure to a
planned shutdown, temporary power
for a small-scale project or a long-term
solution for a mega plant, Energyst can
help. We have a range of Caterpillar
generator sets for every power solution.
From a simple power set up to a multi-
megawatt installation, our modular
solutions work together to generate the
power you need. So if you need 500kVa,
simply rent four of our 125 kVA units.
Our power equipment includes:
• Power Generators up to 2000 kVA
• Cables
• Fuel tanks
• Distribution gear
• Load banks
• Transformers
Our knowledgeable and experienced staff are on hand to answer any questions
or provide more information about how we can help meet your specifi c needs.
INTRODUCINGENERGYST.POWERED BYCATERPILLAR
,
REAL ENERGY COMES FROM ENERGYST
OUR SOLUTIONS
POWERSOLUTIONS
From a sudden power failure to a
planned shutdown, temporary power
for a small-scale project or a long-term
solution for a mega plant, Energyst can
help. We have a range of Caterpillar
generator sets for every power solution.
From a simple power set up to a multi-
megawatt installation, our modular
solutions work together to generate the
power you need. So if you need 500kVa,
simply rent four of our 125 kVA units.
Our power equipment includes:
• Power Generators up to 2000 kVA
• Cables
• Fuel tanks
• Distribution gear
• Load banks
• Transformers
Our knowledgeable and experienced staff are on hand to answer any questions
or provide more information about how we can help meet your specifi c needs.
INTRODUCINGENERGYST.POWERED BYCATERPILLAR
,
REAL ENERGY COMES FROM ENERGYST
OUR SOLUTIONS
POWERSOLUTIONS
From a sudden power failure to a
planned shutdown, temporary power
for a small-scale project or a long-term
solution for a mega plant, Energyst can
help. We have a range of Caterpillar
generator sets for every power solution.
From a simple power set up to a multi-
megawatt installation, our modular
solutions work together to generate the
power you need. So if you need 500kVa,
simply rent four of our 125 kVA units.
Our power equipment includes:
• Power Generators up to 2000 kVA
• Cables
• Fuel tanks
• Distribution gear
• Load banks
• Transformers
Our knowledgeable and experienced staff are on hand to answer any questions
or provide more information about how we can help meet your specifi c needs.
INTRODUCINGENERGYST.POWERED BYCATERPILLAR
WHATEVER POWER YOU NEED FOR YOUR INDUSTRIAL FACILITY
FOR MORE INFORMATION VISIT WWW.ENERGYST.COM
CALL US: UK 0845 769 7450IE 0035 314 018 580
EMAIL US: [email protected]@ENERGYST.COM
• Power Generators up to 2000 kVA• Rigsafe and Norsok Oil & Gas Generators• Cables• Fuel tanks• Distribution gear• Load banks• Transformers
https://www.energyst.com/uk/power/mailto:[email protected]:[email protected]://www.energyst.com/uk/power/www.energyst.comhttps://www.energyst.com/uk/
-
POWER GENERATORS 75 - 275 KVA
TECHNICAL INFORMATION
Caterpillar is the largest producer of medium and high speed diesel engines, and its generators are known worldwide for their safety and reliability. We have temporary generator rental solutions ranging from a simple power set to multi-megawatt installations. It is heavy-duty equipment with low noise and – alongside base load supply – easy to ramp up and down with soft loading and unloading for peaking power.
Our canopied containers are sound insulated, with super-silent models for extra-sensitive environments. The XQE line provides industry leading fuel effi ciency (up to 20% higher) and excellent performance. Ancillaries ensure your power supply meets the
highest safety standards, from HV and LV cables and Powerlock connectors to fuel tanks, and 32- to 3200-A distribution boxes.
Energyst’s fuel-effi cient and low-emission CAT diesel generator solutions: • Form modular systems from 75 to 2000 kVA and above • Produce low diesel and CO2 emissions, meeting or exceeding local and national standards • Come with a standard internal, fully bunded environmentally safe double-walled diesel tank
1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V 3. Fuel consumption measured at 75% load | fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50 Hz at 7m 6. Data at 100% load
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
TECHNICAL INFORMATIONModel XQ75E XQ135E XQP150 EUIIIA XQ150E XQ250E XQ275 EUIIIA
Rating - Prime Prime Prime Prime Prime Prime
Frequency Hz 50 50 50 50 50 50
Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V
Power capacity1 kVA 75 135 150 150 250 275
kW 60 100 120 120 200 220
Output2 A 108 195 217 217 360 398
Breaker 4P A 160 250 250 250 400 630
Fuel tank ltr 593 766 590 766 1200 668
Fuel consumption3 l/hr 18.66 20.9 29.6 23.2 35.2 48
Running time hr 32 37 20 33 34 14
Dimensions [LxWxH] mm 2900 x 1155 x 1940 3570 x 1155 x 2030 3520 x 1120 x 2226 3570 x 1155 x 2030 4250 x 1320 x 2445 4308 x 1500 x 2421
Weight4 without fuel kg 2160 2810 2547 2810 4110 4080
Weight4 with fuel kg 2750 3580 3124 3580 5310 4670
Sound level5 dBA 656 62.8 64 62.8 66.9 66.5
POWER GENERATORS 75 - 275 KVA
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V
3. Fuel consumption measured at 75% load | fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50 Hz at 7m
6. Data at 100% load
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
V7 /
12.1
6 / E
NER
GYS
T
Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.
All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.
STAND-ALONE & EFFICIENT HEAT PUMP RENTAL
ENERGYST HEAT PUMPSSPECIFICATION
HEAT PUMPS 100-300 KW
INSTANT GENERATOR RENTAL – FROM A FEW KW UP TO MULTI MEGAWATTS
75 - 275 KVAPOWER GENERATORS 75 - 275 KVA
TECHNICAL INFORMATION
Caterpillar is the largest producer of medium and high speed diesel engines, and its generators are known worldwide for their safety and reliability. We have temporary generator rental solutions ranging from a simple power set to multi-megawatt installations. It is heavy-duty equipment with low noise and – alongside base load supply – easy to ramp up and down with soft loading and unloading for peaking power.
Our canopied containers are sound insulated, with super-silent models for extra-sensitive environments. The XQE line provides industry leading fuel effi ciency (up to 20% higher) and excellent performance. Ancillaries ensure your power supply meets the
highest safety standards, from HV and LV cables and Powerlock connectors to fuel tanks, and 32- to 3200-A distribution boxes.
Energyst’s fuel-effi cient and low-emission CAT diesel generator solutions: • Form modular systems from 75 to 2000 kVA and above • Produce low diesel and CO2 emissions, meeting or exceeding local and national standards • Come with a standard internal, fully bunded environmentally safe double-walled diesel tank
1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V 3. Fuel consumption measured at 75% load | fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50 Hz at 7m 6. Data at 100% load
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
TECHNICAL INFORMATIONModel XQ75E XQ135E XQP150 EUIIIA XQ150E XQ250E XQ275 EUIIIA
Rating - Prime Prime Prime Prime Prime Prime
Frequency Hz 50 50 50 50 50 50
Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V
Power capacity1 kVA 75 135 150 150 250 275
kW 60 100 120 120 200 220
Output2 A 108 195 217 217 360 398
Breaker 4P A 160 250 250 250 400 630
Fuel tank ltr 593 766 590 766 1200 668
Fuel consumption3 l/hr 18.66 20.9 29.6 23.2 35.2 48
Running time hr 32 37 20 33 34 14
Dimensions [LxWxH] mm 2900 x 1155 x 1940 3570 x 1155 x 2030 3520 x 1120 x 2226 3570 x 1155 x 2030 4250 x 1320 x 2445 4308 x 1500 x 2421
Weight4 without fuel kg 2160 2810 2547 2810 4110 4080
Weight4 with fuel kg 2750 3580 3124 3580 5310 4670
Sound level5 dBA 656 62.8 64 62.8 66.9 66.5
POWER GENERATORS 75 - 275 KVA
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V
3. Fuel consumption measured at 75% load | fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50 Hz at 7m
6. Data at 100% load
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
V7 /
12.1
6 / E
NER
GYS
T
Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.
All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.
STAND-ALONE & EFFICIENT HEAT PUMP RENTAL
ENERGYST HEAT PUMPSSPECIFICATION
HEAT PUMPS 100-300 KW
INSTANT GENERATOR RENTAL – FROM A FEW KW UP TO MULTI MEGAWATTS
75 - 275 KVA
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
60 Hz versions available on request.
The majority of our generators is equipped with remote monitoring.
1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V, 60Hz at 480V 3. Fuel consumption measured at 75% load. Fuel density is 850 G/L 4. Includes oil and coolant, excludes slings.
5. Sound levels given at 75% prime power load 50 Hz at 7m, Sound data 60 Hz is estimated 2 dBa more than 50 Hz based on bare engine data.
6. Design data 7. Data at 100% load
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
TECHNICAL INFORMATIONModel XQ75E XQ135E XQ150E XQ250E
Rating - Prime Prime Prime Prime Prime Prime
Frequency Hz 50 50 50 50 50 50
Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V
Power capacity1 kVA 75 135 150 150 250 275
kW 60 100 120 120 200 220
Output2 A 108 195 217 217 360 398
Breaker 4P A 160 250 250 250 400 630
Fuel tank ltr 593 766 590 766 1200 668
Fuel consumption3 l/hr 18.67 20.9 29.6 23.2 35.2 48
Running time hr 32 37 20 33 34 14
Dimensions [LxWxH] mm 2900 x 1155 x 1940 3570 x 1155 x 2030 3520 x 1120 x 2226 3570 x 1155 x 2030 4250 x 1320 x 2445 4308 x 1500 x 2421
Weight4 without fuel kg 2160 2810 2547 2810 4110 4080
Weight4 with fuel kg 2750 3580 3124 3580 5310 4670
Sound level5 dBA 657 62.8 64 62.8 66.9 66.5
POWER GENERATORS 75 - 275 KVA
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V
3. Fuel consumption measured at 75% load | fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50 Hz at 7m
6. Data at 100% load
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
V7 /
12.1
6 / E
NER
GYST
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
TECHNICAL INFORMATIONModel XQ75E XQ135E XQ150E XQ250E
Rating - Prime Prime Prime Prime Prime Prime
Frequency Hz 50 50 50 50 50 50
Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V
Power capacity1 kVA 75 135 150 150 250 275
kW 60 100 120 120 200 220
Output2 A 108 195 217 217 360 398
Breaker 4P A 160 250 250 250 400 630
Fuel tank ltr 593 766 590 766 1200 668
Fuel consumption3 l/hr 18.67 20.9 29.6 23.2 35.2 48
Running time hr 32 37 20 33 34 14
Dimensions [LxWxH] mm 2900 x 1155 x 1940 3570 x 1155 x 2030 3520 x 1120 x 2226 3570 x 1155 x 2030 4250 x 1320 x 2445 4308 x 1500 x 2421
Weight4 without fuel kg 2160 2810 2547 2810 4110 4080
Weight4 with fuel kg 2750 3580 3124 3580 5310 4670
Sound level5 dBA 657 62.8 64 62.8 66.9 66.5
POWER GENERATORS 75 - 275 KVA
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V
3. Fuel consumption measured at 75% load | fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50 Hz at 7m
6. Data at 100% load
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
V7 /
12.1
6 / E
NER
GYST
1 Performance data quoted in accordance with ISO 8528-1
2 Amps 50Hz at 400V, 60Hz at 480V
3 Fuel consumption measured at 75% load. Fuel density is 850 G/L
4 includes oil and coolant, excludes slings.
5 Sound levels given at 75% prime power load 50 Hz at 7m, Sound data 60 hz is estimated 2 dBa more then 50 hz based on bare engine data.
6 Design data
7 Data at 100% load
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
60 Hz versions available on request
The majority of our rental solutions is equipped with remote monitoring.
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
TECHNICAL INFORMATIONModel XQ75E XQ135E XQ150E XQ250E
Rating - Prime Prime Prime Prime Prime Prime
Frequency Hz 50 50 50 50 50 50
Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V
Power capacity1 kVA 75 135 150 150 250 275
kW 60 100 120 120 200 220
Output2 A 108 195 217 217 360 398
Breaker 4P A 160 250 250 250 400 630
Fuel tank ltr 593 766 590 766 1200 668
Fuel consumption3 l/hr 18.67 20.9 29.6 23.2 35.2 48
Running time hr 32 37 20 33 34 14
Dimensions [LxWxH] mm 2900 x 1155 x 1940 3570 x 1155 x 2030 3520 x 1120 x 2226 3570 x 1155 x 2030 4250 x 1320 x 2445 4308 x 1500 x 2421
Weight4 without fuel kg 2160 2810 2547 2810 4110 4080
Weight4 with fuel kg 2750 3580 3124 3580 5310 4670
Sound level5 dBA 657 62.8 64 62.8 66.9 66.5
POWER GENERATORS 75 - 275 KVA
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V
3. Fuel consumption measured at 75% load | fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50 Hz at 7m
6. Data at 100% load
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
V7 /
12
.16 /
EN
ER
GYS
T
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
TECHNICAL INFORMATIONModel XQ75E XQ135E XQ150E XQ250E
Rating - Prime Prime Prime Prime Prime Prime
Frequency Hz 50 50 50 50 50 50
Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V
Power capacity1 kVA 75 135 150 150 250 275
kW 60 100 120 120 200 220
Output2 A 108 195 217 217 360 398
Breaker 4P A 160 250 250 250 400 630
Fuel tank ltr 593 766 590 766 1200 668
Fuel consumption3 l/hr 18.67 20.9 29.6 23.2 35.2 48
Running time hr 32 37 20 33 34 14
Dimensions [LxWxH] mm 2900 x 1155 x 1940 3570 x 1155 x 2030 3520 x 1120 x 2226 3570 x 1155 x 2030 4250 x 1320 x 2445 4308 x 1500 x 2421
Weight4 without fuel kg 2160 2810 2547 2810 4110 4080
Weight4 with fuel kg 2750 3580 3124 3580 5310 4670
Sound level5 dBA 657 62.8 64 62.8 66.9 66.5
POWER GENERATORS 75 - 275 KVA
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V
3. Fuel consumption measured at 75% load | fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50 Hz at 7m
6. Data at 100% load
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
V7 /
12
.16 /
EN
ER
GYS
T
XQP150 EUIIIa XQ275 EUIIIaXQP100 EUIIIa XQP275 EUIIIa
Prime
50
400V / 230V
100
80
144
200
410
20.3
20
2270 x 1120 x 1846
2027
2456
77.8
Prime
50
400V / 230V
275
220
398
630
717
48.1
15
4065 x 1400 x 2124
3880
4518
66.4
TECHNICAL INFORMATION
https://www.energyst.com/news/power-generators-75-275-kva/https://www.energyst.com/uk/
-
POWER GENERATORS 365 - 500 KVA
TECHNICAL INFORMATION
Caterpillar is the largest producer of medium and high speed diesel engines, and its generators are known worldwide for their safety and reliability. We have temporary generator rental solutions ranging from a simple power set to multi-megawatt installations. It is heavy-duty equipment with low noise and – alongside base load supply – easy to ramp up and down with soft loading and unloading for peaking power.
Our canopied containers are sound insulated, with super-silent models for extra-sensitive environments. The XQE line provides industry leading fuel effi ciency (up to 20% higher) and excellent performance. Ancillaries ensure your power supply meets the
highest safety standards, from HV and LV cables and Powerlock.
Energyst’s fuel-effi cient and low-emission CAT diesel generator solutions:• Form modular systems from 75 to 2000 kVA and above• Produce low emissions, meeting or exceeding local and
national standards• Use DEIF generator controls, with 24/7 remote monitoring
and fully automatic synchronisation between the generators or with the grid for peak shaving
• Come with a standard internal, fully bunded environmentally safe double-walled diesel tank
1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V 3. Fuel consumption measured at 75% load | fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50 Hz at 7m
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
TECHNICAL INFORMATION
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
Model XQ365E XQ455E XQ500 EU3 XQ600E
Rating - Prime Prime Prime Prime
Frequency Hz 50 50 50 50
Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V
Power capacity1 kVA 365 455 500 600
kW 292 364 400 480
Output2 A 527 657 722 866
Breaker 4P A 630 800 800 1600
Fuel tank ltr 1098 1098 1020 1750
Fuel consumption3 l/hr 56.3 65.6 82 104.3
Running time hr 20 17 12 17
Dimensions [LxWxH] mm 5050 x 1800 x 2300 5050 x 1800 x 2300 5325 x 2020 x 2505 6058 x 2438 x 2591
Weight4 without fuel kg 8000 8300 6528 14110
Weight4 with fuel kg 8940 9230 7395 15600
Sound level5 dBA 61.2 59.3 68.5 64.5
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V
3. Fuel consumption measured at 75% load | fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50 Hz at 7m
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
POWER GENERATORS 365 - 600 KVA
Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.
All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.
STAND-ALONE & EFFICIENT HEAT PUMP RENTAL
ENERGYST HEAT PUMPSSPECIFICATION
HEAT PUMPS 100-300 KW
INSTANT GENERATOR RENTAL – FROM A FEW KW UP TO MULTI MEGAWATTS
TECHNICAL INFORMATION
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
Model XQP500 EUIIIA XQ500 EUIIIA XQ600E
Rating - Prime Prime Prime
Frequency Hz 50 50 50
Voltage range V 400V / 230V 400V / 230V 400V / 230V
Power capacity1 kVA 500 500 600
kW 400 400 480
Output2 A 722 722 866
Breaker 4P A 800 800 1600
Fuel tank ltr 965 1020 1750
Fuel consumption3 l/hr 86.8 82 104.3
Running time hr 11 12 17
Dimensions [LxWxH] mm 5103 x 1954 x 2292 5325 x 2020 x 2505 6058 x 2438 x 2591
Weight4 without fuel kg 5977 6528 14110
Weight4 with fuel kg 6879 7395 15600
Sound level5 dBA 67 68.5 64.5
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V
3. Fuel consumption measured at 75% load | fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50 Hz at 7m
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
POWER GENERATORS 500 - 600 KVA
V5 /
12.1
6 / E
NER
GYS
T
POWER GENERATORS 365 - 500 KVA
TECHNICAL INFORMATION
Caterpillar is the largest producer of medium and high speed diesel engines, and its generators are known worldwide for their safety and reliability. We have temporary generator rental solutions ranging from a simple power set to multi-megawatt installations. It is heavy-duty equipment with low noise and – alongside base load supply – easy to ramp up and down with soft loading and unloading for peaking power.
Our canopied containers are sound insulated, with super-silent models for extra-sensitive environments. The XQE line provides industry leading fuel effi ciency (up to 20% higher) and excellent performance. Ancillaries ensure your power supply meets the
highest safety standards, from HV and LV cables and Powerlock.
Energyst’s fuel-effi cient and low-emission CAT diesel generator solutions:• Form modular systems from 75 to 2000 kVA and above• Produce low emissions, meeting or exceeding local and
national standards• Use DEIF generator controls, with 24/7 remote monitoring
and fully automatic synchronisation between the generators or with the grid for peak shaving
• Come with a standard internal, fully bunded environmentally safe double-walled diesel tank
1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V 3. Fuel consumption measured at 75% load | fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50 Hz at 7m
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
TECHNICAL INFORMATION
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
Model XQ365E XQ455E XQ500 EU3 XQ600E
Rating - Prime Prime Prime Prime
Frequency Hz 50 50 50 50
Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V
Power capacity1 kVA 365 455 500 600
kW 292 364 400 480
Output2 A 527 657 722 866
Breaker 4P A 630 800 800 1600
Fuel tank ltr 1098 1098 1020 1750
Fuel consumption3 l/hr 56.3 65.6 82 104.3
Running time hr 20 17 12 17
Dimensions [LxWxH] mm 5050 x 1800 x 2300 5050 x 1800 x 2300 5325 x 2020 x 2505 6058 x 2438 x 2591
Weight4 without fuel kg 8000 8300 6528 14110
Weight4 with fuel kg 8940 9230 7395 15600
Sound level5 dBA 61.2 59.3 68.5 64.5
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V
3. Fuel consumption measured at 75% load | fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50 Hz at 7m
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
POWER GENERATORS 365 - 600 KVA
Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.
All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.
STAND-ALONE & EFFICIENT HEAT PUMP RENTAL
ENERGYST HEAT PUMPSSPECIFICATION
HEAT PUMPS 100-300 KW
INSTANT GENERATOR RENTAL – FROM A FEW KW UP TO MULTI MEGAWATTS
TECHNICAL INFORMATION
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
Model XQP500 EUIIIA XQ500 EUIIIA XQ600E
Rating - Prime Prime Prime
Frequency Hz 50 50 50
Voltage range V 400V / 230V 400V / 230V 400V / 230V
Power capacity1 kVA 500 500 600
kW 400 400 480
Output2 A 722 722 866
Breaker 4P A 800 800 1600
Fuel tank ltr 965 1020 1750
Fuel consumption3 l/hr 86.8 82 104.3
Running time hr 11 12 17
Dimensions [LxWxH] mm 5103 x 1954 x 2292 5325 x 2020 x 2505 6058 x 2438 x 2591
Weight4 without fuel kg 5977 6528 14110
Weight4 with fuel kg 6879 7395 15600
Sound level5 dBA 67 68.5 64.5
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V
3. Fuel consumption measured at 75% load | fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50 Hz at 7m
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
POWER GENERATORS 500 - 600 KVA
V5 /
12.1
6 / E
NER
GYS
T
POWER GENERATORS 500 KVA
TECHNICAL INFORMATION
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
Model
Rating - Prime Prime
Frequency Hz 50 50
Voltage range V 400V / 230V 400V / 230V
Power capacity1 kVA 500 500
kW 400 400
Output2 A 722 722
Breaker 4P A 800 800
Fuel tank ltr 965 1020
Fuel consumption3 l/hr 86.8 73.1
Running time hr 11 14
Dimensions [LxWxH] mm 5103 x 1954 x 2292 5325 x 2020 x 2505
Weight4 without fuel kg 5977 6528
Weight4 with fuel kg 6879 7468
Sound level5 dBA 67 68.5
POWER GENERATORS 500 KVA
V5 /
12.1
6 / E
NER
GYST
1 Performance data quoted in accordance with ISO 8528-1
2 Amps 50Hz at 400V, 60Hz at 480V
3 Fuel consumption measured at 75% load. Fuel density is 850 G/L
4 includes oil and coolant, excludes slings.
5 Sound levels given at 75% prime power load 50 Hz at 7m, Sound data 60 hz is estimated 2 dBa more then 50 Hz based on bare engine data.
6 Design data
7 Data at 100% load
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
60Hz versions available on request
The majority of our rental solutions is equipped with remote monitoring.
XQ500EXQ500 EUIIIaXQP500 EUIIIa
Prime
50
400V / 230V
500
400
722
800
950
76
13
5235 x 1758 x 2546
6225
7033
66.8
TECHNICAL INFORMATION
60 Hz versions available on request.
The majority of our generators is equipped with remote monitoring.
1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V, 60Hz at 480V 3. Fuel consumption measured at 75% load. Fuel density is 850 G/L 4. Includes oil and coolant, excludes slings.
5. Sound levels given at 75% prime power load 50 Hz at 7m, Sound data 60 Hz is estimated 2 dBa more than 50 Hz based on bare engine data.
6. Design data 7. Data at 100% load
https://www.energyst.com/news/power-generators-365-600-kva/https://www.energyst.com/uk/
-
TECHNICAL INFORMATION
Caterpillar is the largest producer of medium and high speed diesel engines, and its generators are known worldwide for their safety and reliability. We have temporary generator rental solutions ranging from a simple power set to multi-megawatt installations. It is heavy-duty equipment with low noise and – alongside base load supply – easy to ramp up and down with soft loading and unloading for peaking power.
Our generators are housed in robust cast-iron 20-foot (diesel only) or 40- foot (diesel and gas) CSC plated ISO containers that are easy to transport by road, sea or air. They are simple to assemble, operate and maintain. The XQE line provides industry leading fuel effi ciency (up to 20% higher) and excellent performance. Ancillaries ensure your power supply meets the highest safety standards, from
HV and LV cables and Powerlock connectors to fuel tanks, and 32- to 3200-A distribution boxes.
Energyst’s fuel-effi cient and low-emission CAT diesel generator solutions:• Form modular systems from 75 to 2000 kVA and above• Produce low emissions, meeting or exceeding local and
national standards• Use DEIF generator controls, with 24/7 remote monitoring
and fully automatic synchronisation between the generators or with the grid for peak shaving
• Come with a standard internal, fully bunded environmentally safe double-walled diesel tanksafe double-walled diesel tank
1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V 3. Fuel consumption measured at 75% load | fuel density is 850 G/L4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50 Hz at 7m
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
TECHNICAL INFORMATION
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
Model XQ810E XQ810E Mera XQ1000E XQ1500E XQ1500 XQ2000E
Rating - Prime Prime Prime Prime Prime Prime
Frequency Hz 50 50 50 50 50 50
Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V
Power capacity1 kVA 810 810 1000 1500 1500 2000
kW 648 648 800 1200 1200 1600
Output2 A 1170 1170 1445 2167 2167 2890
Breaker 4P A 1600 1600 1600 2500 2500 3200
Fuel tank ltr 1750 1750 1200 3500 400 3500
Fuel consumption3 l/hr 126.1 126.1 156.8 225.2 231 306.3
Running time hr 14 14 8 16 2 11
Dimensions [LxWxH] mm 6058 x 2438 x 2591 5900 x 2238 x 2553 6058 x 2438 x 2591 12192 x 2438 x 2591 6058 x 2438 x 2896 12192 x 2438 x 2591
Weight4 without fuel kg 15410 10000 15570 26600 20000 28400
Weight4 with fuel kg 16910 11500 16570 29600 20400 31400
Sound level5 dBA 68 727 69,7 70,5 81 67,2
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V
3. Fuel consumption measured at 75% load | fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50 Hz at 7m
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
POWER GENERATORS 810 - 2000 KVA
Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.
All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.
STAND-ALONE & EFFICIENT HEAT PUMP RENTAL
ENERGYST HEAT PUMPSSPECIFICATION
HEAT PUMPS 100-300 KW
INSTANT GENERATOR RENTAL – FROM A FEW KW UP TO MULTI MEGAWATTS
TECHNICAL INFORMATION
Caterpillar is the largest producer of medium and high speed diesel engines, and its generators are known worldwide for their safety and reliability. We have temporary generator rental solutions ranging from a simple power set to multi-megawatt installations. It is heavy-duty equipment with low noise and – alongside base load supply – easy to ramp up and down with soft loading and unloading for peaking power.
Our generators are housed in robust cast-iron 20-foot (diesel only) or 40- foot (diesel and gas) CSC plated ISO containers that are easy to transport by road, sea or air. They are simple to assemble, operate and maintain. The XQE line provides industry leading fuel effi ciency (up to 20% higher) and excellent performance. Ancillaries ensure your power supply meets the highest safety standards, from
HV and LV cables and Powerlock connectors to fuel tanks, and 32- to 3200-A distribution boxes.
Energyst’s fuel-effi cient and low-emission CAT diesel generator solutions:• Form modular systems from 75 to 2000 kVA and above• Produce low emissions, meeting or exceeding local and
national standards• Use DEIF generator controls, with 24/7 remote monitoring
and fully automatic synchronisation between the generators or with the grid for peak shaving
• Come with a standard internal, fully bunded environmentally safe double-walled diesel tanksafe double-walled diesel tank
1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V 3. Fuel consumption measured at 75% load | fuel density is 850 G/L4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50 Hz at 7m
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
TECHNICAL INFORMATION
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
Model XQ810E XQ810E Mera XQ1000E XQ1500E XQ1500 XQ2000E
Rating - Prime Prime Prime Prime Prime Prime
Frequency Hz 50 50 50 50 50 50
Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V
Power capacity1 kVA 810 810 1000 1500 1500 2000
kW 648 648 800 1200 1200 1600
Output2 A 1170 1170 1445 2167 2167 2890
Breaker 4P A 1600 1600 1600 2500 2500 3200
Fuel tank ltr 1750 1750 1200 3500 400 3500
Fuel consumption3 l/hr 126.1 126.1 156.8 225.2 231 306.3
Running time hr 14 14 8 16 2 11
Dimensions [LxWxH] mm 6058 x 2438 x 2591 5900 x 2238 x 2553 6058 x 2438 x 2591 12192 x 2438 x 2591 6058 x 2438 x 2896 12192 x 2438 x 2591
Weight4 without fuel kg 15410 10000 15570 26600 20000 28400
Weight4 with fuel kg 16910 11500 16570 29600 20400 31400
Sound level5 dBA 68 727 69,7 70,5 81 67,2
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V
3. Fuel consumption measured at 75% load | fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50 Hz at 7m
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
POWER GENERATORS 810 - 2000 KVA
Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.
All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.
STAND-ALONE & EFFICIENT HEAT PUMP RENTAL
ENERGYST HEAT PUMPSSPECIFICATION
HEAT PUMPS 100-300 KW
INSTANT GENERATOR RENTAL – FROM A FEW KW UP TO MULTI MEGAWATTS
POWER GENERATORS 1000 - 2000 KVA
TECHNICAL INFORMATION
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
Model XQ810E XQ810E Mera XQ1000E XQ1500E PM1360 XQ2000E
Rating - Prime Prime Prime Prime Prime Prime
Frequency Hz 50 50 50 50 50 50
Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V
Power capacity1 kVA 810 810 1000 1500 1500 2000
kW 648 648 800 1200 1200 1600
Output2 A 1170 1170 1445 2167 2167 2890
Breaker 4P A 1600 1600 1600 2500 2500 3200
Fuel tank ltr 1750 1750 1200 3500 400 3500
Fuel consumption3 l/hr 126.1 126.1 184 225.2 231 306.3
Running time hr 14 14 8 16 2 11
Dimensions [LxWxH] mm 6058 x 2438 x 2591 5900 x 2238 x 2553 6058 x 2438 x 2591 12192 x 2438 x 2591 6058 x 2438 x 2896 12192 x 2438 x 2591
Weight4 without fuel kg 15410 10000 15570 26600 20000 28400
Weight4 with fuel kg 16910 11500 16570 29600 20400 31400
Sound level5 dBA 68 727 69,7 70,5 81 67,2
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V
3. Fuel consumption measured at 75% load | fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50 Hz at 7m
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
POWER GENERATORS 1000 - 2000 KVA
TECHNICAL INFORMATION
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
Model XQ810E XQ810E Mera XQ1000E XQ1500E PM1360 XQ2000E
Rating - Prime Prime Prime Prime Prime Prime
Frequency Hz 50 50 50 50 50 50
Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V
Power capacity1 kVA 810 810 1000 1500 1500 2000
kW 648 648 800 1200 1200 1600
Output2 A 1170 1170 1445 2167 2167 2890
Breaker 4P A 1600 1600 1600 2500 2500 3200
Fuel tank ltr 1750 1750 1200 3500 400 3500
Fuel consumption3 l/hr 126.1 126.1 184 225.2 231 306.3
Running time hr 14 14 8 16 2 11
Dimensions [LxWxH] mm 6058 x 2438 x 2591 5900 x 2238 x 2553 6058 x 2438 x 2591 12192 x 2438 x 2591 6058 x 2438 x 2896 12192 x 2438 x 2591
Weight4 without fuel kg 15410 10000 15570 26600 20000 28400
Weight4 with fuel kg 16910 11500 16570 29600 20400 31400
Sound level5 dBA 68 727 69,7 70,5 81 67,2
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V
3. Fuel consumption measured at 75% load | fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50 Hz at 7m
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
POWER GENERATORS 1000 - 2000 KVA
TECHNICAL INFORMATION
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
Model XQ810E XQ810E Mera XQ1000E XQ1500E PM1360 XQ2000E
Rating - Prime Prime Prime Prime Prime Prime
Frequency Hz 50 50 50 50 50 50
Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V
Power capacity1 kVA 810 810 1000 1500 1500 2000
kW 648 648 800 1200 1200 1600
Output2 A 1170 1170 1445 2167 2167 2890
Breaker 4P A 1600 1600 1600 2500 2500 3200
Fuel tank ltr 1750 1750 1200 3500 400 3500
Fuel consumption3 l/hr 126.1 126.1 184 225.2 231 306.3
Running time hr 14 14 8 16 2 11
Dimensions [LxWxH] mm 6058 x 2438 x 2591 5900 x 2238 x 2553 6058 x 2438 x 2591 12192 x 2438 x 2591 6058 x 2438 x 2896 12192 x 2438 x 2591
Weight4 without fuel kg 15410 10000 15570 26600 20000 28400
Weight4 with fuel kg 16910 11500 16570 29600 20400 31400
Sound level5 dBA 68 727 69,7 70,5 81 67,2
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V
3. Fuel consumption measured at 75% load | fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50 Hz at 7m
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
POWER GENERATORS 1000 - 2000 KVA
TECHNICAL INFORMATION
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
Model XQ810E XQ810E Mera XQ1000E XQ1500E PM1360 XQ2000E
Rating - Prime Prime Prime Prime Prime Prime
Frequency Hz 50 50 50 50 50 50
Voltage range V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V 400V / 230V
Power capacity1 kVA 810 810 1000 1500 1500 2000
kW 648 648 800 1200 1200 1600
Output2 A 1170 1170 1445 2167 2167 2890
Breaker 4P A 1600 1600 1600 2500 2500 3200
Fuel tank ltr 1750 1750 1200 3500 400 3500
Fuel consumption3 l/hr 126.1 126.1 184 225.2 231 306.3
Running time hr 14 14 8 16 2 11
Dimensions [LxWxH] mm 6058 x 2438 x 2591 5900 x 2238 x 2553 6058 x 2438 x 2591 12192 x 2438 x 2591 6058 x 2438 x 2896 12192 x 2438 x 2591
Weight4 without fuel kg 15410 10000 15570 26600 20000 28400
Weight4 with fuel kg 16910 11500 16570 29600 20400 31400
Sound level5 dBA 68 727 69,7 70,5 81 67,2
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V
3. Fuel consumption measured at 75% load | fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50 Hz at 7m
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
POWER GENERATORS 1000 - 2000 KVA
1 Performance data quoted in accordance with ISO 8528-1
2 Amps 50Hz at 400V, 60Hz at 480V
3 Fuel consumption measured at 75% load. Fuel density is 850 G/L
4 includes oil and coolant, excludes slings
5 Sound levels given at 75% prime power load 50 Hz at 7m, Sound data 60 hz is estimated 2 dBa more then 50 Hz based on bare engine data
6 Design data
7 Data at 100% load
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
60Hz versions available on request
The majority of our rental solutions is equipped with remote monitoring.
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V, 60Hz at 480V 3. Fuel consumption measured at 75%
load. Fuel density is 850 G/L 4. Includes oil and coolant, excludes
slings. 5. Sound levels given at 75% prime power
load 50 Hz at 7m, Sound data 60 Hz is estimated 2 dBa more than 50 Hz based on bare engine data.
6. Design data 7. Data at 100% load
60 Hz versions available on request.
The majority of our generators is equipped with remote monitoring.
https://www.energyst.com/news/power-generators-810-2000-kva/https://www.energyst.com/uk/
-
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
TECHNICAL INFORMATION
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50HZ at 400V | 60Hz at 480V
3. Fuel consumption measured at 75% load | Fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data
6. Design data
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
Model
Rating
Frequency Hz
Voltage range V
Power capacity1 kVA
kW
Output2 A
Breaker 4P A
Fuel tank L
Fuel consumption3 l/hr
Running time hr
Dimensions [LxWxH] mm
Weight4 without fuel kg
Weight4 with fuel kg
Sound level5 dBA
XQ1250E
Prime Standby Prime Standby
50 60
400V / 230V 480V / 277V
1000 1100 1137 1250
800 880 910 1000
1445 1589 1369 1505
1600
1190
162 175 168 200
7 7 7 6
6058 x 2438 x 2590
18140
19152
73.9 73.9 76.8 76.8
OFFSHORE POWER GENERATORS NORSOK XQ1250E
V1 /
12.1
6 / E
NER
GYS
T
TECHNICAL INFORMATION
At Energyst we know that saving space is key in the offshore industry. That is why we put real energy into designing the most compact offshore generator available in the market.
Energyst’s diesel driven generators are manufactured by Caterpillar and are housed in a custom designed offshore rental package comprising of a custom built DNV 2.7-1 certifi ed 20-ft ISO container. The package has been designed to provide fl exibility
for all types of end user operation. The equipment packages are classifi ed NORSOK Z-015 for use in non-hazardous zone. The key safety features outlined within the XQ power modules are: fi re & gas detection and suppression, air shut off, spark arrestor, emergency stop and sea mist fi lter. Our offshore equipment range includes transformers and fuel tanks.
1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V, 60Hz at 480V 3. Fuel consumption measured at 75% load | Fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data 6. Design data
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
Our heat pump rental solutions are stand-alone, closed packagedsystems. They can supply hot and cold water that is transported throughflexible high-pressure hoses to distribution devices.
All our units have a standard design to make assembly, disassembly,installation and maintenance quick and easy. They are easy to transportwith a forklift or a crane. They of course come complete with all theancillaries and fittings you’ll need – like electric cables and water hoses.
STAND-ALONE & EFFICIENT HEAT PUMP RENTAL
ENERGYST HEAT PUMPSSPECIFICATION
HEAT PUMPS 100-300 KW
ENERGYST CAT RENTAL POWER IS BUILT ON THE LATEST OFFSHORE REQUIREMENTS TO MEET THE DEMANDS OF THE ENERGY SECTOR, ENSURING SAFE EQUIPMENT WITH A RELIABLE PARTNER TO SECURE YOUR PRODUCTION.
OFFSHORE POWER GENERATOR NORSOK XQ1250E
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V, 60Hz at 480V3. Fuel consumption measured at 75% load. Fuel density
is 850 G/L 4. Includes oil and coolant, excludes slings.5. Sound levels given at 75% prime power load 50 Hz
at 7m, Sound data 60 Hz is estimated 2 dBa more than 50 Hz based on bare engine data.
6. Design data
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
The majority of our generators is equipped with remote monitoring.
https://www.energyst.com/uk/news/offshore-power-generator-norsok-xq1250e/https://www.energyst.com/uk/
-
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
TECHNICAL INFORMATION
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V | 60Hz at 480V
3. Fuel consumption measured at 75% load | Fuel density is 850 G/L
4. Includes oil and coolant, excludes slings
5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data
6. Design data
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
Model
Rating
Frequency Hz
Voltage range V
Power capacity1 kVA
kW
Output2 A
Breaker 4P A
Fuel tank L
Fuel consumption3 l/hr
Running time hr
Dimensions [LxWxH] mm
Weight4 without fuel kg
Weight4 with fuel kg
Sound level5 dBA
Prime Standby Prime Standby
50 60
400V / 230V 480V / 277V
1500 1650 1700 1870
1200 1320 1360 1496
2167 2384 2047 2251
2500
1650
236 258 269 297
7 6 6 6
6058 x 2438 x 2896
225005
240005
856
OFFSHORE POWER GENERATORS NORSOK XQ1700
TECHNICAL INFORMATION
At Energyst we know that saving space is key in the offshore industry. That is why we put real energy into designing the most compact offshore generator available in the market.
It’s the people at Energyst that make the difference. By listening to the market and transforming its demands into true innovations. On a global level Energyst is the fi rst rental company to introduce a 1700 kVA NORSOK approved generator that fi ts into a 20 foot container. Our latest innovation, designed together with our partner Caterpillar, saves you 50% of space.
Energyst’s diesel driven generators are manufactured by Caterpillar and are housed in a custom designed offshore rental package comprising of a custom built DNV 2.7-1 certifi ed 20-ft ISO container. The package has been designed to provide fl exibility for all types of end user operation.
The equipment packages are classifi ed NORSOK Z-015 for use in nonhazardous zone. The key safety features outlined within the XQ power modules are: fi re & gas detection and suppression, air shut off, spark arrestor, emergency stop and sea mist fi lter. Our offshore equipment range includes transformers and fuel tanks.
1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V, 60Hz at 480V 3. Fuel consumption measured at 75% load | Fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data 6. Design data
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.
All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.
STAND-ALONE & EFFICIENT HEAT PUMP RENTAL
ENERGYST HEAT PUMPSSPECIFICATION
HEAT PUMPS 100-300 KW
ENERGYST CAT RENTAL POWER IS BUILT ON THE LATEST OFFSHORE REQUIREMENTS TO MEET THE DEMANDS OF THE ENERGY SECTOR, ENSURING SAFE EQUIPMENT WITH A RELIABLE PARTNER TO SECURE YOUR PRODUCTION.
OFFSHORE POWER GENERATOR NORSOK 1700
1700
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V, 60Hz at 480V 3. Fuel consumption measured at 75% load. Fuel density
is 850 G/L 4. Includes oil and coolant, excludes slings. 5. Sound levels given at 75% prime power load 50 Hz
at 7m, Sound data 60 Hz is estimated 2 dBa more than 50 Hz based on bare engine data.
6. Design data
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
The majority of our generators is equipped with remote monitoring.
https://www.energyst.com/uk/news/offshore-power-generators-norsok-xq1700/https://www.energyst.com/uk/
-
TECHNICAL INFORMATION
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V | 60Hz at 480V
3. Fuel consumption measured at 75% load | Fuel density is 850 G/L
4. Includes oil and coolant | excludes slings
5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data.
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
OFFSHORE POWER GENERATORS RIGSAFE
Model
Rating
Frequency Hz
Voltage Range V
Power capacity1 kVA
kW
Output2 A
Breaker 4P A
Fuel tank L
Fuel consumption3 l/hr
Running time hr
Dimensions [LxWxH] mm
Weight4 without fuel kg
Weight4 with fuel kg
Sound level5 dBA
XQ250E
Prime Standby Prime Standby
50 60
400V / 230V 480V / 277V
250 275 250 275
200 220 200 220
360 395 305 331
400
1200
35,2 42,1 41,5 48,9
34 29 29 25
4600 x 1800 x 2616
6210
7410
66,9 66,9 68,9 68,9
XQ500E
Prime Standby Prime Standby
50 60
400V / 230V 480V / 277V
500 550 500 562,5
400 440 400 440
722 795 605 677
800
1250
72,6 91,2 81,3 89,6
17 14 15 14
5400 x 2100 x 3130
8875
9683
66,8 66,8 68,8 68,8
V1 /
12.1
6 / E
NER
GYS
T
ENERGYST CAT RENTAL POWER IS BUILT ON THE LATEST OFFSHORE REQUIREMENTSTO MEET THE DEMANDS OF THE INDUSTRY.
OFFSHORE POWER GENERATORS RIGSAFE
ENERGYSTOFFSHORE POWER GENERATORS SPECIFICATION
At Energyst we know that safety is a prerequisite in the offshore industry. That is why, together with our partner Caterpillar, we put real energy into designing the best offshore generators available in the market.
Energyst’s diesel driven Rig Safe generators are manufactured by Caterpillar and are housed in a custom designed offshore rental package comprising of a canopied generator in a DNV 2.7-1 certified lifting frame. The package has been designed to provide flexibility for all types of end user operation. The equipment packages are classified for use in non-hazardous zone.
The key safety features outlined within the XQ power modules are: air shut off, spark arrestor, emergency stop, stainless steel braided fuel lines, anti-static drive belts and ‘Yellow Alert’ rig ESD.
Our offshore equipment range also includes transformers, fuel tanks and NORSOK generators.
1 Chalwyn Valve
2 Exhaust Spark Arrestor
3 ESD Button
4 Anti static drive belts
5 Battery Isolation
6 Yellow alert shutdown module
7 DNV 2.7-1 Offshore lifting frame
8 Generator earth bonded to DNV Frame
9 Braided fuel hoses
10 Front line spares kit
11 Certification document pack
OUTLINE TECHNICAL/SAFETY SPECIFICATION
TECHNICAL INFORMATION
OUTLINE TECHNICAL /SAFETY SPECIFICATION
At Energyst we know that safety is a prerequisite in the offshore industry. That is why, together with our partner Caterpillar, we put real energy into designing the best offshore generators available in the market.
Energyst’s diesel driven Rig Safe generators are manufactured by Caterpillar and are housed in a custom designed offshore rental package comprising of a canopied generator in a DNV 2.7-1 certifi ed lifting frame. The package has been designed to provide fl exibility for all types
of end user operation. The equipment packages are classifi ed for use in non-hazardous zone.
The key safety features outlined within the XQ power modules are: air shut off, spark arrestor, emergency stop, stainless steel braided fuel lines, anti-static drive belts and ‘Yellow Alert’ rig ESD.
Our offshore equipment range also includes transformers, fuel tanks and NORSOK generators.
Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.
All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.
STAND-ALONE & EFFICIENT HEAT PUMP RENTAL
ENERGYST HEAT PUMPSSPECIFICATION
HEAT PUMPS 100-300 KW
ENERGYST CAT RENTAL POWER IS BUILT ON THE LATEST OFFSHOREREQUIREMENTS TO MEET THE DEMANDS OF THE INDUSTRY.
1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V | 60Hz at 480V 3. Fuel consumption measured at 75% load | Fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
TECHNICAL INFORMATION
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V | 60Hz at 480V
3. Fuel consumption measured at 75% load | Fuel density is 850 G/L
4. Includes oil and coolant | excludes slings
5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data.
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
OFFSHORE POWER GENERATORS RIGSAFE
Model
Rating
Frequency Hz
Voltage Range V
Power capacity1 kVA
kW
Output2 A
Breaker 4P A
Fuel tank L
Fuel consumption3 l/hr
Running time hr
Dimensions [LxWxH] mm
Weight4 without fuel kg
Weight4 with fuel kg
Sound level5 dBA
XQ250E
Prime Standby Prime Standby
50 60
400V / 230V 480V / 277V
250 275 250 275
200 220 200 220
360 395 305 331
400
1200
35,2 42,1 41,5 48,9
34 29 29 25
4600 x 1800 x 2616
6210
7410
66,9 66,9 68,9 68,9
XQ500E
Prime Standby Prime Standby
50 60
400V / 230V 480V / 277V
500 550 500 562,5
400 440 400 440
722 795 605 677
800
1250
72,6 91,2 81,3 89,6
17 14 15 14
5400 x 2100 x 3130
8875
9683
66,8 66,8 68,8 68,8
V1 /
12.1
6 / E
NER
GYS
T
ENERGYST CAT RENTAL POWER IS BUILT ON THE LATEST OFFSHORE REQUIREMENTSTO MEET THE DEMANDS OF THE INDUSTRY.
OFFSHORE POWER GENERATORS RIGSAFE
ENERGYSTOFFSHORE POWER GENERATORS SPECIFICATION
At Energyst we know that safety is a prerequisite in the offshore industry. That is why, together with our partner Caterpillar, we put real energy into designing the best offshore generators available in the market.
Energyst’s diesel driven Rig Safe generators are manufactured by Caterpillar and are housed in a custom designed offshore rental package comprising of a canopied generator in a DNV 2.7-1 certified lifting frame. The package has been designed to provide flexibility for all types of end user operation. The equipment packages are classified for use in non-hazardous zone.
The key safety features outlined within the XQ power modules are: air shut off, spark arrestor, emergency stop, stainless steel braided fuel lines, anti-static drive belts and ‘Yellow Alert’ rig ESD.
Our offshore equipment range also includes transformers, fuel tanks and NORSOK generators.
1 Chalwyn Valve
2 Exhaust Spark Arrestor
3 ESD Button
4 Anti static drive belts
5 Battery Isolation
6 Yellow alert shutdown module
7 DNV 2.7-1 Offshore lifting frame
8 Generator earth bonded to DNV Frame
9 Braided fuel hoses
10 Front line spares kit
11 Certification document pack
OUTLINE TECHNICAL/SAFETY SPECIFICATION
TECHNICAL INFORMATION
OUTLINE TECHNICAL /SAFETY SPECIFICATION
At Energyst we know that safety is a prerequisite in the offshore industry. That is why, together with our partner Caterpillar, we put real energy into designing the best offshore generators available in the market.
Energyst’s diesel driven Rig Safe generators are manufactured by Caterpillar and are housed in a custom designed offshore rental package comprising of a canopied generator in a DNV 2.7-1 certifi ed lifting frame. The package has been designed to provide fl exibility for all types
of end user operation. The equipment packages are classifi ed for use in non-hazardous zone.
The key safety features outlined within the XQ power modules are: air shut off, spark arrestor, emergency stop, stainless steel braided fuel lines, anti-static drive belts and ‘Yellow Alert’ rig ESD.
Our offshore equipment range also includes transformers, fuel tanks and NORSOK generators.
Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.
All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.
STAND-ALONE & EFFICIENT HEAT PUMP RENTAL
ENERGYST HEAT PUMPSSPECIFICATION
HEAT PUMPS 100-300 KW
ENERGYST CAT RENTAL POWER IS BUILT ON THE LATEST OFFSHOREREQUIREMENTS TO MEET THE DEMANDS OF THE INDUSTRY.
1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V | 60Hz at 480V 3. Fuel consumption measured at 75% load | Fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
TECHNICAL INFORMATION
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
1. Performance data quoted in accordance with ISO 8528-1
2. Amps 50Hz at 400V | 60Hz at 480V
3. Fuel consumption measured at 75% load | Fuel density is 850 G/L
4. Includes oil and coolant | excludes slings
5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data.
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
OFFSHORE POWER GENERATORS RIGSAFE
Model
Rating
Frequency Hz
Voltage Range V
Power capacity1 kVA
kW
Output2 A
Breaker 4P A
Fuel tank L
Fuel consumption3 l/hr
Running time hr
Dimensions [LxWxH] mm
Weight4 without fuel kg
Weight4 with fuel kg
Sound level5 dBA
XQ250E
Prime Standby Prime Standby
50 60
400V / 230V 480V / 277V
250 275 250 275
200 220 200 220
360 395 305 331
400
1200
35,2 42,1 41,5 48,9
34 29 29 25
4600 x 1800 x 2616
6210
7410
66,9 66,9 68,9 68,9
XQ500E
Prime Standby Prime Standby
50 60
400V / 230V 480V / 277V
500 550 500 562,5
400 440 400 440
722 795 605 677
800
1250
72,6 91,2 81,3 89,6
17 14 15 14
5400 x 2100 x 3130
8875
9683
66,8 66,8 68,8 68,8
V1 /
12.1
6 / E
NER
GYS
T
ENERGYST CAT RENTAL POWER IS BUILT ON THE LATEST OFFSHORE REQUIREMENTSTO MEET THE DEMANDS OF THE INDUSTRY.
OFFSHORE POWER GENERATORS RIGSAFE
ENERGYSTOFFSHORE POWER GENERATORS SPECIFICATION
At Energyst we know that safety is a prerequisite in the offshore industry. That is why, together with our partner Caterpillar, we put real energy into designing the best offshore generators available in the market.
Energyst’s diesel driven Rig Safe generators are manufactured by Caterpillar and are housed in a custom designed offshore rental package comprising of a canopied generator in a DNV 2.7-1 certified lifting frame. The package has been designed to provide flexibility for all types of end user operation. The equipment packages are classified for use in non-hazardous zone.
The key safety features outlined within the XQ power modules are: air shut off, spark arrestor, emergency stop, stainless steel braided fuel lines, anti-static drive belts and ‘Yellow Alert’ rig ESD.
Our offshore equipment range also includes transformers, fuel tanks and NORSOK generators.
1 Chalwyn Valve
2 Exhaust Spark Arrestor
3 ESD Button
4 Anti static drive belts
5 Battery Isolation
6 Yellow alert shutdown module
7 DNV 2.7-1 Offshore lifting frame
8 Generator earth bonded to DNV Frame
9 Braided fuel hoses
10 Front line spares kit
11 Certification document pack
OUTLINE TECHNICAL/SAFETY SPECIFICATION
TECHNICAL INFORMATION
OUTLINE TECHNICAL /SAFETY SPECIFICATION
At Energyst we know that safety is a prerequisite in the offshore industry. That is why, together with our partner Caterpillar, we put real energy into designing the best offshore generators available in the market.
Energyst’s diesel driven Rig Safe generators are manufactured by Caterpillar and are housed in a custom designed offshore rental package comprising of a canopied generator in a DNV 2.7-1 certifi ed lifting frame. The package has been designed to provide fl exibility for all types
of end user operation. The equipment packages are classifi ed for use in non-hazardous zone.
The key safety features outlined within the XQ power modules are: air shut off, spark arrestor, emergency stop, stainless steel braided fuel lines, anti-static drive belts and ‘Yellow Alert’ rig ESD.
Our offshore equipment range also includes transformers, fuel tanks and NORSOK generators.
Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.
All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.
STAND-ALONE & EFFICIENT HEAT PUMP RENTAL
ENERGYST HEAT PUMPSSPECIFICATION
HEAT PUMPS 100-300 KW
ENERGYST CAT RENTAL POWER IS BUILT ON THE LATEST OFFSHOREREQUIREMENTS TO MEET THE DEMANDS OF THE INDUSTRY.
1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V | 60Hz at 480V 3. Fuel consumption measured at 75% load | Fuel density is 850 G/L 4. Includes oil and coolant, excludes slings 5. Sound levels given at 75% prime power load 50Hz at 7m | Sound data 60Hz is estimated 2 dBA more than 50Hz based on bare engine data
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
TECHNICAL INFORMATIONTECHNICAL INFORMATION
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
OFFSHORE POWER GENERATORS RIGSAFE
Model
Rating
Frequency Hz
Voltage Range V
Power capacity1 kVA
kW
Output2 A
Breaker 4P A
Fuel tank L
Fuel consumption3 l/hr
Running time hr
Dimensions [LxWxH] mm
Weight4 without fuel kg
Weight4 with fuel kg
Sound level5 dBA
XQ250E
Prime Standby Prime Standby
50 60
400V / 230V 480V / 277V
250 275 250 275
200 220 200 220
360 395 305 331
400
1200
35,2 42,1 41,5 48,9
34 29 29 25
4600 x 1800 x 2616
6210
7410
66,9 66,9 68,9 68,9
XQ500E
Prime Standby Prime Standby
50 60
400V / 230V 480V / 277V
500 550 500 562,5
400 440 400 440
722 795 605 677
800
1250
91,2 81,3 89,6
17 14 15 14
5400 x 2100 x 3130
8875
9683
66,8 66,8 68,8 68,8
V1 /
12.1
6 / E
NER
GYST
TECHNICAL INFORMATION
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
OFFSHORE POWER GENERATORS RIGSAFE
Model
Rating
Frequency Hz
Voltage Range V
Power capacity1 kVA
kW
Output2 A
Breaker 4P A
Fuel tank L
Fuel consumption3 l/hr
Running time hr
Dimensions [LxWxH] mm
Weight4 without fuel kg
Weight4 with fuel kg
Sound level5 dBA
XQ250E
Prime Standby Prime Standby
50 60
400V / 230V 480V / 277V
250 275 250 275
200 220 200 220
360 395 305 331
400
1200
35,2 42,1 41,5 48,9
34 29 29 25
4600 x 1800 x 2616
6210
7410
66,9 66,9 68,9 68,9
XQ500E
Prime Standby Prime Standby
50 60
400V / 230V 480V / 277V
500 550 500 562,5
400 440 400 440
722 795 605 677
800
1250
7 91,2 81,3 89,6
17 14 15 14
5400 x 2100 x 3130
8875
9683
66,8 66,8 68,8 68,8
V1 /
12.1
6 / E
NER
GYST
1 Performance data quoted in accordance with ISO 8528-1
2 Amps 50Hz at 400V, 60Hz at 480V
3 Fuel consumption measured at 75% load. Fuel density is 850 G/L
4 includes oil and coolant, excludes slings.
5 Sound levels given at 75% prime power load 50 Hz at 7m, Sound data 60 Hz is estimated 2 dBa more then 50 Hz based on bare engine data.
6 Design data
7 Data at 100% load
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
60Hz versions available on request
The majority of our rental solutions is equipped with remote monitoring.
Model
Rating
Frequency
Voltage Range
Power capacity1
Output
Breaker 4P
Fuel tank
Fuel consumption3
Running time
Dimensions [LxWxH]
Including offshoreframe
Weight4 without fuel
Including offshoreframe
Weight4 with fuel
Including offshoreframe
Sound level5
XQ500E
Prime Standby Prime Standby
50 60
400V / 230V 480V / 277V
500 550 500 562,5
400 440 400 440
722 795 605 677
800
1250
72.6 91.2 81.3 89.6
17 14 15 14
4995 x 1798 x 2513
5650 x 2200 x 2966
6225
8875
7033
9683
66.8 66.8 68.8 68.8
XQ250E
Prime Standby Prime Standby
50 60
400V / 230V 480V / 277V
250 275 250 275
200 220 200 220
360 395 305 331
400
1200
35.2 42.1 41.5 48.9
34 29 29 25
4150 x 1395 x 2140
4600 x 1800 x 2616
4110
6210
5310
7410
66.9 66.9 68.9 68.9
Hz
V
kVA
kW
A2
A
L
L/hr
hr
mm
mm
kg
kg
kg
kg
dBA
60 Hz versions available on request.The majority of our generators is equipped with remote monitoring.
1. Performance data quoted in accordance with ISO 8528-1 2. Amps 50Hz at 400V, 60Hz at 480V 3. Fuel consumption measured at 75% load. Fuel density is 850 G/L 4. Includes oil and coolant, excludes slings.
5. Sound levels given at 75% prime power load 50 Hz at 7m, Sound data 60 Hz is estimated 2 dBa more then 50 Hz based on bare engine data.
6. Design data 7. Data at 100% load
OFFSHORE POWER GENERATORS RIGSAFE
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
https://www.energyst.com/uk/news/offshore-power-generator/https://www.energyst.com/uk/
-
TECHNICAL INFORMATION
For an effi cient operation of our generators Energyst offers a range of ancillaries for rent, including effi cient and environmentally-safe diesel fuel tanks. Our range of fuel tank hire solutions is UN compliant and in conformity with IBC environmental regulations. They allow environmentally safe supply of fuel to Energyst equipment where an auxiliary source is required or if the equipment’s own internal tank does not allow suffi cient running time.
The robust CSC plated, pressure tested containers are equipped with quick release couplings, fork lift pockets on four sides and a lockable, vandal-proof access hatch. They ensure safe and secure containment of bulk fuel supplies for generators, heaters and hot water systems.
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
TECHNICAL INFORMATIONModel 1000 3000 8000 15000 27000
Tank size / capacity ltr 1,000 3,000 8,000 15,000 27,000
Type - Eurocube IBC Eurocube IBC 10 ft ISO container 20 ft ISO container CSC
plated20 ft HC container
Connections 3/8” - 2 2 - - -
Connections 3/4” - 2 2 2 3 8
Connections 1” - 1 1 2 4 0
Bund alarm - Electronic Electronic Visual Visual No
Inspection manhole - 1 1 1 2 2
Heater connection - 2" 2" - 2" 2"
Dipstick - No No No Yes No
Forklift pockets - 2 sides 2 sides 1 side 1 side No
Fuel fill - 3" 3" 2" 3" 3"
Grenzwertgeber fill connection
- Yes Yes Yes Yes No
Lockable - Yes Yes Yes Yes Yes
Dimensions [LxWxH] mm 1200 x 1200 x 1250 2400 x 1200 x 1600 2991 x 2438 x 2438 6058 x 2348 x 2590 6058 x 2348 x 2900
Weight empty kg 450 950 4400 6250 8500
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
FUEL TANKS 1,000 – 27,000 LITRES
Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.
All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.
STAND-ALONE & EFFICIENT HEAT PUMP RENTAL
ENERGYST HEAT PUMPSSPECIFICATION
HEAT PUMPS 100-300 KW
OUR FUEL TANKS ARE SPECIALLY DESIGNED TO COMPLEMENT OURPOWER GENERATION AND TEMPERATURE CONTROL RENTAL FLEET
TECHNICAL INFORMATION
For an effi cient operation of our generators Energyst offers a range of ancillaries for rent, including effi cient and environmentally-safe diesel fuel tanks. Our range of fuel tank hire solutions is UN compliant and in conformity with IBC environmental regulations. They allow environmentally safe supply of fuel to Energyst equipment where an auxiliary source is required or if the equipment’s own internal tank does not allow suffi cient running time.
The robust CSC plated, pressure tested containers are equipped with quick release couplings, fork lift pockets on four sides and a lockable, vandal-proof access hatch. They ensure safe and secure containment of bulk fuel supplies for generators, heaters and hot water systems.
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
TECHNICAL INFORMATIONModel 1000 3000 8000 15000 27000
Tank size / capacity ltr 1,000 3,000 8,000 15,000 27,000
Type - Eurocube IBC Eurocube IBC 10 ft ISO container 20 ft ISO container CSC
plated20 ft HC container
Connections 3/8” - 2 2 - - -
Connections 3/4” - 2 2 2 3 8
Connections 1” - 1 1 2 4 0
Bund alarm - Electronic Electronic Visual Visual No
Inspection manhole - 1 1 1 2 2
Heater connection - 2" 2" - 2" 2"
Dipstick - No No No Yes No
Forklift pockets - 2 sides 2 sides 1 side 1 side No
Fuel fill - 3" 3" 2" 3" 3"
Grenzwertgeber fill connection
- Yes Yes Yes Yes No
Lockable - Yes Yes Yes Yes Yes
Dimensions [LxWxH] mm 1200 x 1200 x 1250 2400 x 1200 x 1600 2991 x 2438 x 2438 6058 x 2348 x 2590 6058 x 2348 x 2900
Weight empty kg 450 950 4400 6250 8500
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
FUEL TANKS 1,000 – 27,000 LITRES
Our heat pump rental solutions are stand-alone, closed packaged systems. They can supply hot and cold water that is transported through flexible high-pressure hoses to distribution devices.
All our units have a standard design to make assembly, disassembly, installation and maintenance quick and easy. They are easy to transport with a forklift or a crane. They of course come complete with all the ancillaries and fittings you’ll need – like electric cables and water hoses.
STAND-ALONE & EFFICIENT HEAT PUMP RENTAL
ENERGYST HEAT PUMPSSPECIFICATION
HEAT PUMPS 100-300 KW
OUR FUEL TANKS ARE SPECIALLY DESIGNED TO COMPLEMENT OURPOWER GENERATION AND TEMPERATURE CONTROL RENTAL FLEET
TECHNICAL INFORMATION
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
TECHNICAL INFORMATIONModel 1000 3000 8000 15000 27000
Tank size / capacity ltr 1,000 3,000 8,000 15,000 27,000
Type - Eurocube IBC Eurocube IBC 10 ft ISO container 20 ft ISO container CSC
plated20 ft HC container
Connections 3/8” - 2 2 - - -
Connections 3/4” - 2 2 2 3 8
Connections 1” - 1 1 2 4 0
Bund alarm - Electronic Electronic Visual Visual No
Inspection manhole - 1 1 1 2 2
Heater connection - 2" 2" - 2" 2"
Dipstick - No No No Yes No
Forklift pockets - 2 sides 2 sides 1 side 1 side No
Fuel fill - 3" 3" 2" 3" 3"
Grenzwertgeber fill connection
- Yes Yes Yes Yes No
Lockable - Yes Yes Yes Yes Yes
Dimensions [LxWxH] mm 1200 x 1200 x 1250 2400 x 1200 x 1600 2991 x 2438 x 2438 6058 x 2348 x 2590 6058 x 2348 x 2900
Weight empty kg 450 950 4400 6250 8500
Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
FUEL TANKS 1,000 – 27,000 LITRES
WE’D LIKE TO HEAR FROM YOU
CALL US: 00800 3637 4978EMAIL US: [email protected]
If you would like to talk to us, request a rental or have a question there are two ways to contact us.
TECHNICAL INFORMATIONModel 1000 3000 8000 15000 27000
Tank size / capacity ltr 1,000 3,000 8,000 15,00