readers & controllers quick installation guide

19
Readers & Controllers Quick Installation Guide R11C-30 2020/03/23

Upload: others

Post on 23-Jun-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Readers & Controllers Quick Installation Guide

Readers & Controllers

Quick Installation Guide

R11C-30

2020/03/23

Page 2: Readers & Controllers Quick Installation Guide

www.acti.com

Quick Installation Guide

2

Table of Contents

Part 1: Installation and Wiring ............................... 3

Installation ................................................................................................ 3

Cabling Instructions ................................................................................. 4

Connectors Diagram ............................................................................. 4

Wiring Instructions ................................................................................ 6

Part 2: Basic Settings ............................................. 8

Step 1: Go to SETTINGS .......................................................................... 8

Step 2: Set the Language ........................................................................ 9

Step 3: Change Password ...................................................................... 11

Part 3: Other Configurations ................................ 12

Configure IP Address ............................................................................. 12

Configure RELAY ................................................................................... 16

Restore to Default Factory Settings ..................................................... 18

Page 3: Readers & Controllers Quick Installation Guide

www.acti.com

Quick Installation Guide

3

Thank you for using ACTi Reader. This documentation contains basic settings of

your device. If you wish to add users, it is recommended to add users through the

Access Control Standard Server (ACSS). For more information, please refer to

the ACSS manual.

Part 1: Installation and Wiring

Installation

Attach the waterproof strip to the mounting plate.

Pull the cables from the square hole of the mounting plate.

Use a screwdriver to screw the base onto the wall.

Connect the terminal cables to the body and attach the body to the

mounting plate.

Assemble the covers with the bundled Allen key and scres.

Turn on the power, the LED will light and a beep will sound, you will see

“Ready” on the LCD screen.

Page 4: Readers & Controllers Quick Installation Guide

www.acti.com

Quick Installation Guide

4

Cabling Instructions

Connectors Diagram

Cable: CN4 (Main cable)

Wire Application Wire Color Description

Lock Relay 1 Blue - White Normal On (N.O.)

2 Purple – White Normal Close (N.C.)

Lock Relay COM 3 White COM

Door Contact 4 Orange Negative Trigger Input

Exit Switch 5 Purple Negative Trigger Input

Alarm Relay 6 Gray DC24V1Amp

Power 7 Red DC 12V

8 Black DC 0V

Page 5: Readers & Controllers Quick Installation Guide

www.acti.com

Quick Installation Guide

5

Cable: CN5 (Wiegand DI/DO Wiring)

Wire Application Wire Color Description

Beeper 1 Pink Beeper Output 5V/100mA,

Low

LED 2 Yellow Red LED Output 5V/20mA,

Max

3 Brown Green LED Output 5V/20mA,

Max

Door Output 4 Blue – White

Transistor Output Max.

12V/100mA

(Open collector Active Low)

Wiegand

5 Green Wiegand DAT: 0 Input

6 Blue Wiegand DATA: 1 Input

WG Door

Contact 7 Orange Negative Trigger Input

WG Door Switch 8 Purple Negative Trigger Input

Cable: CN7 (Network Wiring)

Wire Application Wire Color Description

1 --- ---

2 --- ---

TCP/IP Output 3 Orange-White Net - TX+

4 Orange Net - TX-

5 Green - White Net - RX+

6 Green Net - RX-

7 --- ---

Page 6: Readers & Controllers Quick Installation Guide

www.acti.com

Quick Installation Guide

6

Wiring Instructions

A. Connecting the Reader / Controller and Exit Switch

+

EXIT

Exit Switch

GND

N.O.

+

-

E

-

+

Exit PB

0V

12V DC 12V

DC 0V

Electric Lock

CN4

1

2

3

4

5

6

7

8

N.O.

COM

12V

0V (GND) )

PB

R11C-30

DC 12V

DC 0V -

Page 7: Readers & Controllers Quick Installation Guide

www.acti.com

Quick Installation Guide

7

B. Controlling Entry / Exit of Two or More Readers / Controllers

1

2

3

4

5

6

7

8

N.O.

COM

12V

0V(GND)

PB

+

-

E

-

+

Exit PB

0V

12V DC 12V

DC 0V

Electric Lock

CN4

1

2

3

4

5

6

7

8

N.O.

COM

12V

0V (GND)

PB

R11C-30

DC 12V

DC 0V -

+

-

+ DC 12V

DC 0V

R11C-30

Page 8: Readers & Controllers Quick Installation Guide

www.acti.com

Quick Installation Guide

8

Part 2: Basic Settings

Step 1: Go to SETTINGS

Press “*123456#” to enter the device SETTINGS.

Use the F1 , F2 keys to scroll up or down.

Use the * key to select an item and # key to enter menu.

Press * to select item.

Pressor #

Press F1 and F2 keys to

scroll up or down

Press # to enter.

Page 9: Readers & Controllers Quick Installation Guide

www.acti.com

Quick Installation Guide

9

Step 2: Set the Language

1. In SETTINGS, select “5. Tools“ then press # to enter the menu.

2. Select “1. Language”.

3. Enter the corresponding number of the preferred language. A confirmation

message will appear. Press * to exit the menu.

Page 10: Readers & Controllers Quick Installation Guide

www.acti.com

Quick Installation Guide

10

4. Select “Quit” to exit SETTINGS and return to the Standby screen.

Page 11: Readers & Controllers Quick Installation Guide

www.acti.com

Quick Installation Guide

11

Step 3: Change Password

1. Go to SETTINGS and select “5. Tools”.

2. Select “ 2. Master Code”.

3. Enter the new password and then press # to confirm.

Page 12: Readers & Controllers Quick Installation Guide

www.acti.com

Quick Installation Guide

12

Part 3: Other Configurations

Configure IP Address

1. Go to SETTINGS, select “3. Parameters (1)”.

2. Select “1. Node ID”.

Page 13: Readers & Controllers Quick Installation Guide

www.acti.com

Quick Installation Guide

13

3. Retain the preset value (default value is 1), press # to confirm.

4. Retain the preset value of the Main Door Controller (default value is 1),

press # to confirm.

5. Retain the preset value of Weigand 1 WG1 (default value is 1), press # to

confirm.

6. The LCD display shows a confirmation message, set to “1” to enable

Page 14: Readers & Controllers Quick Installation Guide

www.acti.com

Quick Installation Guide

14

weigand, then press # to confirm.

7. Set the device IP.

To Enable DHCP

To enable DHCP, select “1. Enable”. When done, the device will

automatically restart and apply the setting.

To Disable DHCP

a. If DHCP will not be used, enter a static IP address, then press # to

confirm.

Page 15: Readers & Controllers Quick Installation Guide

www.acti.com

Quick Installation Guide

15

b. Enter the Subnet Mask, press # to confirm.

c. Enter the Gateway, then press # to confirm.

When done, the device will automatically restart and apply the setting.

Page 16: Readers & Controllers Quick Installation Guide

www.acti.com

Quick Installation Guide

16

Configure RELAY

You can set the relay interval when a door opens and closes on the device.

1. Go to SETTINGS, select “3. Parameters (1)”.

2. Select “3. Door Relay Tm”.

3. Set the time interval, then press # to confirm.

Page 17: Readers & Controllers Quick Installation Guide

www.acti.com

Quick Installation Guide

17

4. If using a Wiegand control electric lock, you need to set the relay of the

Wiegand. Press # to confirm.

Page 18: Readers & Controllers Quick Installation Guide

www.acti.com

Quick Installation Guide

18

Restore to Default Factory Settings

If necessary, you can restore the device default factory settings.

1. Go to SETTINGS, select “4. Parameters (2)”.

2. Select “9. Factory Reset”.

3. Select the corresponding number of the item to reset. You can reset either

the System settings or User settings or both. The device will automatically

restart after confirmation.

Page 19: Readers & Controllers Quick Installation Guide

Copyright © 2020, ACTi Corporation All Rights Reserved

7F, No. 1, Alley 20, Lane 407, Sec. 2, Ti-Ding Blvd., Neihu District, Taipei, Taiwan 114, R.O.C.

TEL : +886-2-2656-2588 FAX : +886-2-2656-2599

Email: [email protected]