ray set chirurgia guidata brochure

2
Ray Set The Ray Set® PROCEDURE is an extraoral protocol based on five geometrical coordinates finalized to tran- sfer, directly on the patient model, all implants three- dimensional positions virtually defined by the dedica- ted Implant3D software. Thanks to the fiducial marker at 0° degrees inserted in the Rx template, the software program for the data elaboration concurs at the threedimensional definition of the implants position in connection with the ana- tomical paraxial and panoramic planes, prosthetically involved. The faithful reproduction of the single implant posi- tion on the master model, by means of the implant analog insertion and the treatment simulation, offers the opportunity to provide a surgical template prosthe- tically coordinate and then the prosthetic device ready to the immediate load. The Ray Set® DELTA apparatus is a special parallelo- meter able to define the axes relative to the implants positions, their inclinations on the relative MD LL bidi- mensional plans and the vertical heights parameters. The RTT base is characterized by three movement planes at right angles (orthogonal) to each other and allows the spatial location of the implant analogs that will be inserted into the patient model, according to the informatic surgical plan. The Ray Set® RTT BASE manages two angular coordinates finalized to implant positioning on its own labio-lingual and mesio-distal planes. The Delta device with the vertical measurement gauge provide three metric coordinates to control all bodily adjustment required to put the implant in a correct relation with the bone crestal ridge. The implant 3d software provides a printed template finalized to verify the surgical project development in the patient model. It verifies the correct application of all prescriptions supplied by the software. Biaggini Medical Devices srl Via Aurelia Nord 340 A/B • 19021 ARCOLA (SP) • Italy Tel. (+39) 0187-50.95.75 • Fax (+39) 0187-59.90.76 [email protected] • www.biaggini.it EXACTA WP0 Ø 3,30mm L. 9mm 11mm 13mm 15mm EXACTA WP1 Ø 4,00mm L. 7mm 9mm 11mm 13mm 15mm EXACTA WP2 Ø 4,35mm L. 7mm 9mm 11mm 13mm 15mm EXACTA WP3 Ø 4,70mm L. 7mm 9mm 11mm 13mm 15mm Replacing multirooted teeth, two regular implants pla- tform results in a geometric risk score. In these cases, alternative wide platform implants pro- vide increased mechanical strength and greater load support than two regular implant platform. The up-to-dated morphology of the Wide Plat-form implants, by a progressive thread design, sets up the most recent biological and prosthetic innovations. The advanced thread design on the cervical implant portion, through the blood clot retention, concurs to the healing process for a predictable bone level main- tenance, considering the biological deficit of the cre- stal cortical bone. Several studies have demonstrate that the attachment of osteoblasts is dependent on the surface roughness. Is well-known today that sandblasted and acid- etched modified surfaces can reduce the healing time, shorte- ning the unloaded period. A special polishing treatment of the implant neck sur- face allows the implant fitting one millimeter above the bone crest in order to have a transmucous fitting, if required, as the gold colored trans gingival collar as- sures the improved aesthetic appearance. The original vectorial mechanics of abutments con- nection concurs to control any bacterial contamination and prosthetic screws stability. Ray Set RTT base Ray Set apparatus WP wide platform implant 15 25 35 45 Excacta surgical guide kit Ray Set chirurgia Guidata Brochure.indd 1 14/04/11 10:03

Upload: biaggini-medical-devices

Post on 30-Mar-2016

216 views

Category:

Documents


1 download

DESCRIPTION

Ray Set chirurgia Guidata Brochure

TRANSCRIPT

Ray SetThe Ray Set® PROCEDURE is an extraoral protocol based on five geometrical coordinates finalized to tran-sfer, directly on the patient model, all implants three-dimensional positions virtually defined by the dedica-ted Implant3D software.

Thanks to the fiducial marker at 0° degrees inserted in the Rx template, the software program for the data elaboration concurs at the threedimensional definition of the implants position in connection with the ana-tomical paraxial and panoramic planes, prosthetically involved.

The faithful reproduction of the single implant posi-tion on the master model, by means of the implant analog insertion and the treatment simulation, offers the opportunity to provide a surgical template prosthe-tically coordinate and then the prosthetic device ready to the immediate load.

The Ray Set® DELTA apparatus is a special parallelo-meter able to define the axes relative to the implants positions, their inclinations on the relative MD LL bidi-mensional plans and the vertical heights parameters.

The RTT base is characterized by three movement planes at right angles (orthogonal) to each other and allows the spatial location of the implant analogs that will be inserted into the patient model, according to the informatic surgical plan.

The Ray Set® RTT BASE manages two angular coordinates finalized to implant positioning on its own labio-lingual and mesio-distal planes.

The Delta device with the vertical measurement gauge provide three metric coordinates to control all bodily adjustment required to put the implant in a correct relation with the bone crestal ridge.

The implant 3d software provides a printed template finalized to verify the surgical project development in the patient model.

It verifies the correct application of all prescriptions supplied by the software.

Biaggini Medical Devices srlVia Aurelia Nord 340 A/B • 19021 ARCOLA (SP) • ItalyTel. (+39) 0187-50.95.75 • Fax (+39) 0187-59.90.76 [email protected] • www.biaggini.it

EXACTA WP0 Ø 3,30mm • L. 9mm 11mm 13mm 15mmEXACTA WP1 Ø 4,00mm • L. 7mm 9mm 11mm 13mm 15mmEXACTA WP2 Ø 4,35mm • L. 7mm 9mm 11mm 13mm 15mmEXACTA WP3 Ø 4,70mm • L. 7mm 9mm 11mm 13mm 15mm

Replacing multirooted teeth, two regular implants pla-tform results in a geometric risk score.

In these cases, alternative wide platform implants pro-vide increased mechanical strength and greater load support than two regular implant platform.

The up-to-dated morphology of the Wide Plat-form implants, by a progressive thread design, sets up the most recent biological and prosthetic innovations.

The advanced thread design on the cervical implant portion, through the blood clot retention, concurs to the healing process for a predictable bone level main-tenance, considering the biological deficit of the cre-stal cortical bone.

Several studies have demonstrate that the attachment of osteoblasts is dependent on the surface roughness.

Is well-known today that sandblasted and acid- etched modified surfaces can reduce the healing time, shorte-ning the unloaded period.

A special polishing treatment of the implant neck sur-face allows the implant fitting one millimeter above the bone crest in order to have a transmucous fitting, if required, as the gold colored trans gingival collar as-sures the improved aesthetic appearance.

The original vectorial mechanics of abutments con-nection concurs to control any bacterial contamination and prosthetic screws stability.

Ray Set

RTT base

Ray Set apparatus

WPwide platform implant

15253545

Excacta surgical guide kit

Ray Set chirurgia Guidata Brochure.indd 1 14/04/11 10:03

SOFTWAREIMPLANT 3DIMPLANT 3D OVERVIEW

Implant3D is a software package that allows you to per-form a 3D implant simulation directly on your PC. You can simulate the implant position on 2D & 3D mo-dels, identify the mandibular canal, draw bone model panoramics and sections, show the 3D bone model and calculate the bone density. By means of Implant3D you can plan the prothesis implant operation more safely, ef-ficiently and quickly.

Supported FormatsImplant3D reads CAT scans from CD-ROM in more than 60 formats, including Dicom 3.0 medical format.

Measures & InformationImplant3D helps you to plan the prothesis implant ope-ration by identifying both the implants and mandibular canal positions. You can perform accurate measurements and calculate the bone density. This is a great aid to per-form the operation more effectively and quickly.

2D & 3DImplant3D generates the panoramic, the sections and the 3D bone model through reading the axial images. This enables you to know both the patient anatomic model under all respects and the exact implant position as to the mandibular canal and the bone structure before the dental operation.

A Useful Communication & Motivation ToolYou can use the images produced by Implant3D to com-municate with the patient in compliance with the rules about the informed consent. Through the image exporting functions you can save your most interesting cases on a CD-ROM. Thanks to the user-friendly interface, learning is a quick matter

Verification and Certification procedure

The informatic printed support provides a verification tem-plate in order to verify the surgical project development.

It verifies the correct application of the software prescriptions.The verification printed template reproduces an horizon-tal scanning plan elaborated by the software, contextually to the definition of all the Ray Set® parameters.

This plan indicates the intersection points of the virtual implants occlusal axes extension concurring to compare, on a printed card, the coincidence with the same axes extension of the implant analogs.

Once the implant analogs are inserted into the model and the control pins, reproducing scan plan height, are mounted on each of them, the precision of the procedu-res can be controlled and stated simply turning upside down the model on the printed template marks and con-trolling a perfect correspondence relation.(At least two implants are necessary)

Hardware Requirement for Implant3D:• Pentium III 600 Mhz minimum, IntelCentrino Duo or higher suggested.• RAM: 512 MB minimum, 2GB suggested.• 3D video acceleretor with driverOpenGL 1.2 or higher, NVidia Graphic Card class 7000 or 8000 suggested.• OS Windows® 98 OSR2 with IE 5.01 or higher, Windows® NT4.0, Windows® ME, Windows® 2000, Windows® XP Pro, Windows® Vista®

IMPLANT 3DDental Implant Simulation

Media Lab Software

Rx template

Rx axial plane

Paraxial vector

Rx paraxial plane

Anchorage pins virtual positioning

Anchorage pins control view

The implant replicas insertion

Mounting pivot and surgical tubes

Surgical stent with anchorage pins

Surgical project card with Ray Set parameters

Surgical stent

Surgical stent and EXACTA WP implant

The fundamental goal of the Ray Set procedure is to have the prosthetic device ready to load, at the same implant placement time

The operative sequence:

1 • The diagnostic Rx Stent construction for the anatomical bone structure evaluation and the prosthodontics treatment planning.2 • The virtual simulation of the surgical treatment related to the prosthodontics plain.3 • The surgical plan reproduction on the cast, by fitting the implant replicas inside.4 • The surgical stent construction.5 • The provisional prostheses construction, ready for immediate implant loading

A feasibility study is the first procedure step by selecting the implant sizes and positions and then adequate prosthetic implant solutions.

The Ray Set Implant3D Software, thanks to diagnostic stent references, planned at zero degrees by the resetted model holder base RTT, can provides the following spatial coordinates of the selected implant position:

1 • The Implant angulation on the paraxial plain (labio-lingual plain)2 • The implant angulation on the panoramic plain (mesio-distal plain)3 • The implant bodily position on the labio-lingual plain4 • The implant bodily position on the mesio-distal plain5 • The eight position of the implant top, related to the bone ridge profile and the soft tissues thickness 6 • The surgical pins position for the surgical stent anchorage.

The Ray Set objectives:

• The construction of a rx template, based on three-dimensional geometrical concepts• A virtual surgical project on five space coordinates• The development and simulation of the informatic project on the model cast• The construction of surgical stent coordinated with the prosthetic plan• The preconstruction of a prosthetic device ready to load• The aesthetic and functional requirements in a single session• The development of the surgical project on the model• The certification for the med-legal requirements

Ray Set