18 Q&A Session Q1. Max Ong, Norimax Sdn Bhd How far is the spread of one sensor to another? Q2. Dr. Hamed Mohebbi, PETRONAS Carigali Sdn Bhd / Universiti Teknologi PETRONAS What is the feedback of using Thermal Sprayed Aluminium (TSA) on large area e.g. tank? RapporteursReport on IMM one day Conference on Corrosion Under Insulation (CUI) 2016 Prepared by: Mr. Leow Chun Ho (Sarawak Shell Berhad), Ms. Elizah Samat (Sarawak Shell Berhad), Dr. Kee Kok Eng (Universiti Teknologi PETRONAS) Edited by: Ir. Ong Hock Guan, Sarawak Shell Berhad (IMM Corrosion Committee, Chairperson) Mr. David Lake It depends on the type of materials. For instance stainless steel material, the spread is about 2 - 3m, for carbon steel about 70 - 80m. Higherattenuation will lead to longer distance of each sensor Mr. Rehan Ahmed Based on the case study, inspection was done last year by stripping off the insulation and no CUI was observed. The speaker also stressed on the importance to ensure perfect TSA coating and the challenges to do so. Q3. Mr. Rehan Ahmed Organization of COE Maintenance Excellence Asset Integrity Team, PETRONAS What is the difference between Acoustic Emission (AE) and Magnetostrictive Sensor (MsS)? Mr. Jeremy Yeo Sze Yew It depends on the objective of the inspection and available budget. MsS is cheaper and has the capability to detect thinning location while AE noiseis always a concern. Q4. Ir. Dr. Mokhtar Che Ismail, Universiti Teknologi PETRONAS Have Shell experienced and witness the self-healing effect of the viscoelastic material? Mr. Hafiz Zakaria Yes. Shell witnessed the testing before through a trial session. It took up to a day to self-heal the defect at ambient temperature. Q5. Dr. Hamed Mohebbi, PETRONAS Carigali Sdn Bhd / Universiti Teknologi PETRONAS What is the performance of inorganic zinc coating under insulation? Ir. Dr. Mokhtar Che Ismail Under reverse polarity >60 degree Celcius, zinc will become cathodic. It is recommended to refer to NACE SP0198 to understand more on the precaution of using inorganic zinc. Q6. Mr. Kamin, Malakoff Power Bhd What is the thickness limitation for resistance based sensor (RBS)? Ir. Dr. Mokhtar Che Ismail For small RBS used in laboratory, the usage is limited to surface area for minimum 1mm pipe thickness. Q7. Elizah Samat, Sarawak Shell Bhd What is the performance of non-contact insulation? Mr. Rehan Ahmed Non-contact insulation is not very effective. Some form of contact is desirable especially in cyclic condition. Q8. Max Ong, Norimax Sdn Bhd Why there is no testing on new coating at Universiti Teknologi PETRONAS? Ir. Dr. Mokhtar Che Ismail Testing of new coating can be done with the existing laboratory facility in UTP. However, it requires protocol that is able to simulate the actual environment e.g. ASTM 189. Q9. Ir. Ong Hock Guan , Sarawak Shell Bhd What if client refused to perform detailed study on insulation during design stage? Dr. Lee Chee Hong It is essential to be extra careful to identify or design out the potential CUI during initial stage (eg. desktop/ modelling study). Rapporteurs: 1. Mr. Leow Chun Ho, Sarawak Shell Berhad (Leader) 2. Ms. Elizah Samat, Sarawak Shell Berhad 3. Dr. Kee Kok Eng, Universiti Teknologi Petronas Date : 13 th October 2016 Time : 7.30 am to 5.00 pm Venue : Ballroom 1, Level 1, Corus Hotel, Kuala Lumpur No. of participants : 129

Upload: dinhthuan

Post on 14-Jun-2018

220 views

Category:

Documents


0 download

TRANSCRIPT

18

Q&A Session Q1. Max Ong, Norimax Sdn Bhd How far is the spread of one sensor to another?

Q2. Dr. Hamed Mohebbi, PETRONAS Carigali Sdn Bhd / Universiti Teknologi PETRONAS What is the feedback of using Thermal Sprayed Aluminium (TSA) on large area e.g. tank?

Rapporteurs’ Report on IMM one day Conference on Corrosion Under Insulation (CUI) 2016

Prepared by: Mr. Leow Chun Ho (Sarawak Shell Berhad), Ms. Elizah Samat (Sarawak Shell Berhad), Dr. Kee Kok Eng (Universiti Teknologi PETRONAS) Edited by: Ir. Ong Hock Guan, Sarawak Shell Berhad (IMM Corrosion Committee, Chairperson)

Mr. David Lake

It depends on the type of materials. For instance stainless steel material, the spread is about 2 - 3m, for carbon steel about 70 - 80m. Higherattenuation will lead to longer distance of each sensor

Mr. Rehan Ahmed Based on the case study, inspection was done last year by stripping off the insulation and no CUI was observed. The speaker also stressed on the importance to ensure perfect TSA coating and the

challenges to do so.

Q3. Mr. Rehan Ahmed Organization of COE Maintenance Excellence Asset Integrity Team, PETRONAS What is the difference between Acoustic Emission (AE) and Magnetostrictive Sensor (MsS)?

Mr. Jeremy Yeo Sze Yew It depends on the objective of the inspection and available budget. MsS is cheaper and has the capability to detect thinning location while AE “noise” is always a concern.

Q4. Ir. Dr. Mokhtar Che Ismail, Universiti Teknologi PETRONAS

Have Shell experienced and witness the self-healing effect of the viscoelastic material?

Mr. Hafiz Zakaria Yes. Shell witnessed the testing before through a trial session. It took up to a day to self-heal the defect at ambient temperature.

Q5. Dr. Hamed Mohebbi, PETRONAS Carigali Sdn Bhd /Universiti Teknologi PETRONAS

What is the performance of inorganic zinc coating under insulation?

Ir. Dr. Mokhtar Che Ismail Under reverse polarity >60 degree Celcius, zinc will become cathodic. It is recommended to refer to NACE SP0198 to understand more on the precaution of using inorganic zinc.

Q6. Mr. Kamin, Malakoff Power Bhd What is the thickness limitation for resistance

based sensor (RBS)?

Ir. Dr. Mokhtar Che Ismail For small RBS used in laboratory, the usage is limited to surface area for minimum 1mm pipe thickness.

Q7. Elizah Samat, Sarawak Shell Bhd What is the performance of non-contact

insulation?

Mr. Rehan Ahmed Non-contact insulation is not very effective. Some form of contact is desirable especially in cyclic condition.

Q8. Max Ong, Norimax Sdn Bhd Why there is no testing on new coating at Universiti Teknologi PETRONAS?

Ir. Dr. Mokhtar Che Ismail Testing of new coating can be done with the existing laboratory facility in UTP. However, it requires protocol that is able to simulate the actual environment e.g. ASTM 189.

Q9. Ir. Ong Hock Guan, Sarawak Shell Bhd What if client refused to perform detailed

study on insulation during design stage?

Dr. Lee Chee Hong It is essential to be extra careful to identify or design out the potential CUI during initial stage (eg. desktop/ modelling study).

Rapporteurs: 1. Mr. Leow Chun Ho, Sarawak Shell Berhad (Leader) 2. Ms. Elizah Samat, Sarawak Shell Berhad 3. Dr. Kee Kok Eng, Universiti Teknologi Petronas

Date : 13th

October 2016 Time : 7.30 am to 5.00 pm Venue : Ballroom 1, Level 1, Corus Hotel, Kuala Lumpur No. of participants : 129

19

Q10. Question submitted via whatsapp What is the latest industrial insulation painting available in the market? If yes, any tests being performed?

Mr. Benson Soon Metal coating is used to protect the metal material. NACE SP0198 prefers multi-layer hybrid coating to protect insulation. So far, only water based ceramic coating is used with certain limitations. However, there is no testing done thus far.