RADIOGRAPHY FOR DENTISTRY 1
DR.SAMY I AL-AGHAA PROFESSOR OF RADIOLOGY
AL-AZHAR UNIVERCITY
![Page 2: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/2.jpg)
X-RAY IMAGE RECEPTORS
• 1-CONVENTIONAL X-RAY FILMS
• 2-DIGITAL IMAGE RECEPTORS
![Page 3: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/3.jpg)
X-RAY FILM COMPOSITION
1-Film base2-Adhesive layer3-Film emulsion : a-Gelatin b-Silver halide crystals4-Protective layer
![Page 4: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/4.jpg)
RADIOGRAPHIC FILM
![Page 5: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/5.jpg)
FILM EMULSION
• SILVER HALIDES:1-AgBr2-Ag I3-Agcl
![Page 6: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/6.jpg)
LATENT IMAGE
Ag Br + X-ray or light---Ag+ Br-(latent image)
![Page 7: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/7.jpg)
CONVENTIONAL X-RAY FILMS
1-INTRA-ORAL FILMS
2-EXTRA-ORAL FILMS
![Page 8: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/8.jpg)
INTRA-ORAL X-RAY FILMS
1-X-Ray film2- Two black papers3-Lead foil sheet4-Outer wrapping(soft packet) a-Tube side(white surface) b-Label side(colour coded)
![Page 9: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/9.jpg)
KODAK PACKET COLOR CODES
One – film packet
Two-film packets
Ultra-speed(D-speed) GREEN GRAY
Ekta-speed(E-speed) BLUE PINK
![Page 10: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/10.jpg)
TYPES OF INTRA-ORAL FILMS
1-PERIAPICAL FILMS
2-BITEWING FILMS
3-OCCLUSAL FILMS
![Page 11: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/11.jpg)
PERIAPICAL FILMS
Size 0 :For children&adults with small mouth
Size 1: For anterior teeth in adultsSize 2:(standard film) For
anterior&posterior teeth in adults
![Page 12: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/12.jpg)
BITE-WING FILMS
Size 0 For posterior teeth in young childrenSize 1 For posterior teeth in childrenSize 2 For posterior teeth in adults(most
frequent film)Size 3 For premolar or molar region
![Page 13: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/13.jpg)
OCCLUSAL FILMS
Size 4: To show large areas of upper or lower jaw
![Page 14: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/14.jpg)
FILM SPEED(SENSITIVITY)
It is exposure time necessary to produce an image on the film
Determined by 1-Size of silver halide crystals 2-Thickness of emulsion
Classified from A-speed(slowest) to F-speed(fastest)
![Page 15: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/15.jpg)
FILM SPEED(SENSITIVITY)
Large crystals>>>High speed>>>less details
Small crystals>>>slow speed>>>More details
A-speed films>>>slowest speed &best detailsF-speed films>>>fastest speed &less details
![Page 16: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/16.jpg)
EXTRA-ORAL FILMSTYPES : 1-Screen films 2-non screen filmsINDICATIONS: 1-PTS unable to open mouth2-view large area of pathology3-general view of mandible or maxilla4-view more bones of the face(skull or sinuses)5-impacted or unerupted teeth6-fractures of jaws&localization of F.B7-TM joint
![Page 17: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/17.jpg)
INTENSIFYING SCREEN
COMPOSITION OF I. S.1-Plastic or cardboard sheet2-Reflecting layer (Titanium oxide)3-Phosphor layer: a-Ca Tungestate or Ba Ld sulfate(conventional
screen) b-Gd or Lanthanum (rare earth screen)
![Page 18: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/18.jpg)
INTENSIFYING SCREEN
TYPESA-According to phosphor layer1-Conventional screen>>>Emit blue light
Kodak x-omatic screen 2-Rare earth screen >>> emit green light Kodak Lanex screen
![Page 19: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/19.jpg)
INTENSIFYING SCREEN
B-ACCORDING TO SPEED (Crystal size)1-Slow : small crystals>>best image details
2-Intermediate : Larger crystals>> less details
3-Fast : Largest crystals >> Least details
![Page 20: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/20.jpg)
CASSETTE HOLDERS
1-Cassette front :Plastic, cardboad or Alaminium2-Two Intensifying screens3- Film4-Felt padding5-Cassette back : Lead
![Page 21: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/21.jpg)
FILM STORAGE
Avoid high temperature , chemical fumes , radiation & mechanical pressure
Proper storage conditions:1-Cool ,dry place (no humidity)2-No chemical fumes3-Lead lining of storage area4-Standing film boxes
![Page 22: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/22.jpg)
DIGITAL RADIOGRAPHY
DISADVANTAGES OF CONVENTIONAL RADIOGRAPHY
1-Processing the films2-Use of high radiation dose3-The image cannot be changed4-Sensitive to variation in exposure5-Less sensitive to detect early osseous changes
![Page 23: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/23.jpg)
DIGITAL RADIOGRAPHY
ADVANTAGES OF DIGITAL RADIOGRAPHY1-Low radiation dose2-Image manipulation>>adjust
contrast ,resolusion &image enhancement3-No processing4-Teleradiology5-Storage &archiving of patient imagings
![Page 24: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/24.jpg)
DIGITAL RADIOGRAPHY
DISADVANTAGES OF DIGITAL RADIOGRAPHY1-Expensive2-Needs large disc spaces3-Electronic failure4-Difficult in intra-oral radiography
![Page 25: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/25.jpg)
DIGITAL RADIOGRAPHY
1-Charge coupled device(CCD) systemComposed of a rare earth screen(in rigid plastic
casing)>>conical optical fibers &CCD>>display processing unit(DPU)
PRINSIPLE: X-ray photons strike the screen>>emits light>>transferred by optical fibers>>CCD>>Electrical signals>>digital signals by computer(A/D convertor)
![Page 26: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/26.jpg)
DIGITAL RADIOGRAPHY
2-IMAGE PLATE (IP) SYSTEMCONSISTS OF phosphor particles embeded in a
polymer and coated on a plastic basePRINCIPLE:PHOTOSTIMULABLE LUMINESCENCESome of energy is stored in the screen>>latent
image>>electrical signals(by photomultiplier tubes)>>digital signals(by A/D converter)
![Page 27: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/27.jpg)
FACTORS AFFECTING IMAGE
1-FACTORS RELATED TO X-RAY MACHINE
2-FACTORS RELATED TO OBJECT
3-FACTORS RELATED TO X-RAY FILM
![Page 28: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/28.jpg)
FACTORS AFFECTING IMAGE
A-FACTORS RELATED TO X-RAY MACHINE1-KV2-MA3-EXP TIME(S)4-COLLIMATION5-FILTRATION6-SOURCE-OBJECT DISTANCE
![Page 29: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/29.jpg)
FACTORS AFFECTING IMAGE
1-KV KV of dental x-ray machines from 65-90kv Increase KV(within normal range)>>X-ray high
energy photons >>more penetration power>>>>GOOD CONTRAST(differentiation between black ,white &gray shades
Optimal contrast is between65-90KV KV affects the quality of X-ray beam
![Page 30: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/30.jpg)
FACTORS AFFECTING IMAGE2-mA
Normal mA of dental X-ray machines 8-12mA Increase mA (within normal range)>>increase heating
the filament>>increase No of X-ray photons>>increase degree of darkening of image(good or optimal DENSITY)
mA affects quantity of X-ray beam Difference in mA can be controlled by change of
exposure time(S )
![Page 31: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/31.jpg)
FACTORS AFFECTING IMAGE
3-EXPOSURE TIME (S) Exposure= Ma X sec Affects quantity of X-ray beam
![Page 32: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/32.jpg)
FACTORS AFFECTING IMAGE
4-COLLIMATION Good collimation >> restriction of x-ray beam >>decrease tissue exposure (safety of patients) Proper collimation >> decreases secondary
radiation&increases quality & sharpness of the image
![Page 33: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/33.jpg)
FACTORS AFFECTING IMAGE
5-FILTRATION Filter is a thin sheets of AL which absorb weak x-
ray photons Thickness of AL sheets depends on KVp of x-ray
machines 1.5mm AL for KV up to 70 KVp 2.5mm AL for KV over 70 KVp Proper filtration improves quality of
beam>>patient safety &better image quality
![Page 34: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/34.jpg)
FACTORS AFFECTING IMAGE
6-SOURCE-OBJECT DISTANCEINVERSE SQUARE LAW
![Page 35: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/35.jpg)
FACTORS AFFECTING IMAGE
B-FACTORS RELATED TO OBJECT1-Atomic No2-Density3-Thickness of object
![Page 36: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/36.jpg)
IMAGE CLARITY
SHARPNESS: It is a measure of how well the minimum details of object are seen on the radiograph
RESOLUTION: It is a measure of visualization small objects on the radiograph
![Page 37: RADIOGRAPHY FOR DENTISTRY 1 DR.SAMY I AL-AGHA A PROFESSOR OF RADIOLOGY AL-AZHAR UNIVERCITY](https://reader035.vdocuments.site/reader035/viewer/2022062421/56649dd35503460f94acaf2f/html5/thumbnails/37.jpg)