radioblator rf 4mhz

4
4 MHz Radiofrequenz-Gerät mit bipolarem Modus für die Wirbelsäulenchirurgie Focus on Effect Radioblator RF 4 MHz Multidisciplinary radiofrequency surgical device

Upload: phamnhan

Post on 04-Jan-2017

412 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: RADIOBLATOR RF 4MHz

4 MHz Radiofrequenz-Gerät mit bipolarem Modus für die Wirbelsäulenchirurgie

Focus on Effect

Spec

ifica

tions

sub

ject

to c

hang

e w

ithou

t not

ice.

B 79

9.VI

II.14

.EN

.1 Radioblator RF 4 MHzMultidisciplinary radiofrequency surgical device

Page 2: RADIOBLATOR RF 4MHz

Radioblator RF 4 MHzConserving frequency for sensitive structures

Focus on Effect

The precisely focused effect of the 4 MHz technology to conserve peripheral

tissue makes the Radioblator RF 4 MHz ideal for applications close to sensitive

structures, as necessary in e.g. neurosurgery and spine surgery. The complete

radiofrequency surgery solution offers efficient vaporization, gentle coagulation

and a range of cutting modes in monopolar or bipolar operation.

02

Pioneering technologies

The patented automatic control of

the RF current, corresponding to

the impedance of the tissue, allows

surgeons to achieve a uniform quality

for the desired tissue effects. This

applies to all monopolar and bipolar

modes.

An intelligent, pulsed power output

permits a high energy input into the

tissue during coagulation without

undesired carbonization effects in

the tissue and therefore guarantees

adequate hemostasis.

Specialist full-endoscopic spine surgery

The significantly reduced lateral

spread of heat makes working close

to sensitive structures, e.g. nerves,

much more exact and reduces risk.

The use of different bipolar currents

enables the surgeon to achieve the

desired effects of gentle coagulation

to aggressive vaporization or ablation

to suit individual circumstances and

situations.

4 MHz – on one wavelength with precision

As the frequency of the electric

current rises, the electrical resistance

of the biological tissue falls. At the

4 MHz operating frequency of the

Radioblator RF 4 MHz Generator, the

cell membranes are capacitively

bridged such that the thermal effect

of the electrical fields acts directly in

the cells.

Page 3: RADIOBLATOR RF 4MHz

Experts in many specialist areas

The Radioblator RF 4 MHz Generator

can be used in the operating room

for a large number of electrosurgical

functions by implementing a wide

range of operating modes. The

Radioblator is very easy to operate

and the opportunities offered by

programming application-specific

parameters allow it to be used in an

approach for the following areas:

Orthopedics

Neurosurgery

Ear, nose and throat medicine

Oral and maxillofacial surgery

Plastic /Cosmetic surgery

Dermatology

Lateral thinking round corners – the TipControl Concept

TipControl is a series of instruments

articulated at the distal end. They are

used especially in full-endoscopic

operations on the spine in order to

achieve adequate scope of move-

ment through minimally invasive

ports to the operating site. The

TipControl electrodes also enable

surgeons to use this intelligent

concept for all RF applications.

03

Page 4: RADIOBLATOR RF 4MHz

www.richard-wolf.com

Spec

ifica

tions

sub

ject

to c

hang

e w

ithou

t not

ice.

B 79

9.VI

II.14

.EN

.1

Radioblator RF 4 MHz System

Radioblator RF System set comprising:Radioblator RF System (2330001), power/mains cable (244003), double-pedal foot switch (2330901) and cable for disposable neutral electrodes (2330045) ...................................... 23300011

TipControl RF accessories, bipolar

TipControl RF Instrument Set short, WL 290 mmcomprising:Handle bipolar (899351100), sheath tube short, OD 2.5 mm (899351010) ..... 899351000

TipControl RF electrode, short, sterile, pack of 5 ........................................................................................... 499351000

TipControl RF Instrument Set long, WL 400 mmcomprising:Handle bipolar (899351100), sheath tube long, OD 2.5 mm (899352010) ...... 899352000

TipControl RF electrode, long, sterile, pack of 5 ........................................................................................... 499352000

TipControl connection cable, bipolar, connection cable for EU flat connector, 2-PIN International power plug, cable length 3 m ............................................. 899351210

Ablation electrodes, bipolar – for application from 5.6 mm working channel

Bipolar hollow-sphere electrode,WL 330 mm, for single use

distal head part OD 2.9 mm ........................................................................... 899364300

distal head part OD 3.4 mm ........................................................................... 899364400

also:Electrode handle, bipolar, for accommodating bipolar hollow-sphere electrodes, fixed cable with 2-PIN International power plug, cable length 3 m ...................... 899364200

RF accessories, monopolar

Monopolar handlewith cable 4 m, for electrodes with shaft 2.4 mm, for US generators and Erbe "International" ....................................................... 89910.0001

Disposable neutral electrodes,Pack of 50, packed single, non-sterile ................................................................... 433015

Cablefor disposable neutral electrodes, cable length 3 m ............................................... 2330045

Radioblator RF 4 MHzand accessories