radifield total solution - emv service radifield bundle 2016-03 e.pdf · radifield® total solution...
TRANSCRIPT
RadiField® Total Solution1 - 6 GHz Radiated Immunity Test System
Ser rr ice
emv Service GmbHOhmstr. 1183607 HolzkirchenGermany
T: +49 (0) 8024 470 08-0M: [email protected]: www.emv-service.com
RadiCentre® Multifunctional EMC test system
RadiField® 1-6 GHz @ 10 V/m field generator
RadiTower® mast with automatic H/V positioner
RadiGen® 9 kHz to 6 GHz signal generator
RadiSense® 10 MHz to 6 GHz field probe
RadiSwitch® coaxial switch card
RadiMation® Full package EMC test SW
Complete set of test accessories
Excluding VAT and
transportation
costswww.dare.eu
The Standard in EMC Instruments & Software,
Consultancy and Training.
Copyright© 2016 All rights reserved by DARE!! Instruments
Ser rr ice
emv Service GmbHOhmstr. 1183607 HolzkirchenGermany
T: +49 (0) 8024 470 08-0M: [email protected]: www.emv-service.com
7
7” TFT / WVGA (800x480)
Intelligent versatile backplane
19’ wide - 3U, 132mm (h) x 312mm (d)
7 kg
Linux
RS232, USB, LAN, GPIB-488
1 GHz – 6 GHz
10 V/m
N-type
0 dBm
11 kg
2 (forward + reflected)
integrated
9 kHz – 6 GHz
-70 dBm to +10 dBm
< 500 µs
2x sma, LF output + HF output
CW, AM, Pulse and Gated Pulse
< 20 ppm
1 Hz
10 MHz – 6 GHz
0.5 V/m to 600 V/m
1500 V/m
± 3.0 dB (1 GHz to 6 GHz)
± 0.5 dB +/- 0.5 V/m
< ± 0.25 dB @ 1 GHz
52 cm3
2 meter
Non reflective
manual
Automatic H/V
Through RadiField® supply card
RadiField® Total SolutionTechnical Specifications
For more information contact DARE!! Instruments at:
T: +31 348 416 592 M: [email protected] W: www.dare.eu
Performance
Number of slots for Plug-in Cards
Display (TFT touch screen)
Backplane
Dimensions
Weight
Operating System
Interfaces
Performance
Frequency range
Three Meter Equivalent (TME) Field1
Input connector
Max. input power to reach TME Field1
Weight
Number of internal power meters
Directional coupler
Performance
Frequency range
Output level range
Output level settling time
Output connector
Modulation types
Frequency error
Frequency resolution
Performance
Frequency range
Measuring range
Maximum input level
Frequency response
Linearity
Isotropic deviation
Electrical measuring volume
Performance
Mast height
Type
Height adjustment
Antenna polarisation
H/V control
1) Three Meter Equivalent (TME) Field: 1,5 m x 1,5m Homogeneous field @ 3 m and 2 dB field compression according to IEC 61000-4-3
RadiCentre® CTR1009B#020
RadiField® RFS1006B
RadiGen® RGN6000B
RadiSense® RSS1006A
RadiTower® RTW2000A
Copyright© 2016 All rights reserved by DARE!! Instruments