Page 1: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

Radiation and Fluoroscopic EquipmentTour of Ionizing Lab

1

Page 2: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

What to Expect this Week….

Radiation Equipment and Tour

• Radiation Equipment• X-ray Tube components• Main components of

Fluoroscopic Equipment• Tour of Lab

Assignments

• Discussion Question Due• QUIZ 1

2

Page 3: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

3

Page 4: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

Terminology• X-ray tube assembly• Collimator• Radiographic table• Bucky tray• Wall Bucky tray• Tube support• Generator• Control console• Free floating• Kilovoltage• Millamperes• Exposure• Mobile radiography• Radiolucent• Radio-opaque• Thermionic emission• Focusing cup• Terminal-positive, negative

• Longitudinal• Vertical• Transverse• Alignment• Table top• Tube angulation• Image receptor• Cassette• Computed radiography• Digital radiography• Fluoroscopy• PACS• Post processing• Viewing station• Current• Kinetic energy• Potential energy• Pyrex glass

4

Page 5: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

Radiation Equipment

Inside the x-ray room Outside the x-ray room

5

Page 6: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

X-ray Tube Assembly

Cathode Terminal, Anode Terminal

6

Page 7: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

Collimator Assembly

7

Page 8: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

Collimator Assembly

8

Page 9: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

Xray Table Apparatus

9Fluoroscopy tube and table

Page 10: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

X-ray tube and table movements

10

Page 11: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

X-ray table apparatus

11

Page 12: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

X-ray Table Apparatus

12

Page 13: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

X-ray Table Apparatus

13

Page 14: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

Image Receptors

14

Page 15: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

Potter-Bucky tray

15

Page 16: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

16

Wall Bucky Tray

Page 17: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

Control Panel• Factors that

technologist can control from the control panel are:

• Kilovoltage of x-ray• Milliampere of x-ray• Time of exposure

17

Page 18: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

Control Panel

18

Page 19: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

Ancillary Equipment

19

Page 20: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

Portable X-ray

20

Page 21: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

X-ray Tube Assembly

Cathode Terminal Anode Terminal

21

• Positive charge when kilovoltage applied• Tungsten target• Rotating vs. fixed target

• Negative charge when millamps applied• Tungsten filament• Focusing cup• Thermionic emission

Page 22: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

Miscellaneous equipmentPositioning spongesTapeLead apronsLead blockersMarkersSand bagslinens

22

Page 23: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

1

2

3 3

4

5

6

7. Describe Tube Travel

8. Describe tube travel

9. Describe how the tube would travel in order to direct x-ray output at #1??

23

Page 24: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

Lab Tour

24

Page 25: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

X-ray Tube Assembly

25

Page 26: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

X-ray Tube Assembly

26

Page 27: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

X-ray Tube Assembly

Cathode

• Negative terminal• Tungsten filament• Focusing cup• Milliamps applied• Determines amount of

electrons • Thermionic emission

Anode

• Positive terminal• Tungsten target• Rotating or fixed target• Target angle• Neck of anode• Rotor, stators

27

Page 28: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

Cathode Terminal

28

• Negative terminal• Tungsten filament• Focusing cup• Milliamps applied• Determines amount of

electrons • Thermionic emission

Page 29: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

Anode Terminal

29

• Positive terminal• Tungsten target• Rotating or fixed target• Target angle• Neck of anode• Rotor, stators• Kilovoltage applied

Page 30: Radiation and Fluoroscopic Equipment Tour of Ionizing Lab 1

X-ray Tube Housing

30

Pyrex glass encasementWindow for x-rays to exitLead and steel Oil for cooling