r82 — excelon® plus modular system pressure regulators

7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2020 Norgren Ltd 01/20 en us 8.105.855 Technical features Technical data R82G *1) All models shown here are supplied with integrated gauge applicable for flow direction left to right. With flow direction right to left please use the online configurator www.imi-precision.com/air-preparation-configurator or contact Norgren. > Port size: 1/4” & 3/8” (ISO G/PTF) > Excelon® Plus design allows in-line installation or modular installation with other Excelon® Plus products > Push to lock adjusting knob with built in tamper resistant feature > Easy to read flush mounted integrated pressure gauge as standard Medium: Compressed air only Maximum supply pressure: 290 psi (20 bar) Outlet pressure ranges: 4 to 145 psi, (0.3 to 10 bar) 4 to 58 psi, ( 0.3 to 4 bar) 10 to 247 psi, (0.7 to 17 bar) Port size: G1/4, G3/8, 1/4 PTF, 3/8 PTF Gauge: Integrated as standard Gauge port 1/8 as option Diaphragm Type: Relieving Flow: 69 scfm (33 dm 3 /s) at port size 1/4”, 66 scfm (31 dm 3 /s) at port size 3/8”, inlet pressure 145 psi (10 bar), operating pressure 91 psi (6.3 bar) and a Δp: 14.5 psi (1.0 bar) drop from set. Ambient/Media temperature: -4 ... +149ºF (-20 ... +65ºC) Air supply must be dry enough to avoid ice formation at temperatures below +35°F (+2°C). Materials: Body: Die cast aluminium Body covers: ABS Bonnet: POM/Aluminium Valve: PP Elastomers: NBR R82 — Excelon® Plus Modular System Pressure Regulators 1/4 4 to 145 (0.3 to 10) Knob 0 to 145 psi (0 to 10) 0.50 (0.23) R82G-2AK RMG 3/8 4 to 145 (0.3 to 10) Knob 0 to 145 psi (0 to 10) 0.50 (0.23) R82G-3AK-RMG Symbol Port Size Pressure range Adjustment Integrated gauge Weight lb (kg) Model *1 (PTF) psi (bar) psi (bar) R82HH H H– R H H Option selector *1) Substitute G R Substitute 2 3 Substitute A G Substitute K T*2) Flow General Reverse Flow Port size 1/4“ 3/8“ Thread form PTF ISO G parallel Adjustment Knob T-bar Gauge Substitute With (fitted integrated gauge) G Without integrated gauge N but with gauge port 1/8” Pressure range *3) Substitute 4 to 58 psi (0.3 to 4 bar) F 4 to 145 psi (0.3 to 10 bar) M 1 0 to 247 psi (0.7 to 17 bar) S*2) *3) Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges. *1) All models shown here are applicable for flow direction left to right. With flow direction right to left please use the online configurator www.imi-precision.com/air-preparation-configurator or contact Norgren. *2) Units with 247 psi outlet pressure range are available only with the T-bar adjustment; therefore substitute T at the 7th position and S at the 9th position. T-bar handle only available with 247 psi option.

Upload: others

Post on 01-Mar-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

Factory Automation

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2020 Norgren Ltd

01/20en us 8.105.855

Technical features

Technical data R82G

*1) All models shown here are supplied with integrated gauge applicable for flow direction left to right. With flow direction right to left please use the online configurator www.imi-precision.com/air-preparation-configurator or contact Norgren.

> Port size: 1/4” & 3/8” (ISO G/PTF)

> Excelon® Plus design allows in-line installationormodular installationwithother Excelon® Plus products

> Pushtolockadjusting knobwithbuiltintamper resistantfeature

> Easytoreadflushmountedintegrated pressure gauge

asstandard

Medium:Compressed air only

Maximumsupplypressure:290 psi (20 bar)

Outlet pressure ranges:4 to 145 psi, (0.3 to 10 bar)4 to 58 psi, ( 0.3 to 4 bar)10 to 247 psi, (0.7 to 17 bar)

Port size:G1/4, G3/8, 1/4 PTF, 3/8 PTF

Gauge:Integrated as standardGauge port 1/8 as option

DiaphragmType:Relieving

Flow:69 scfm (33 dm3/s) at port size 1/4”,66 scfm (31 dm3/s) at port size 3/8”,inlet pressure 145 psi (10 bar), operating pressure 91 psi (6.3 bar) and a Δp: 14.5 psi (1.0 bar) dropfrom set.

Ambient/Mediatemperature:-4 ... +149ºF (-20 ... +65ºC)Air supply must be dry enoughto avoid ice formation attemperatures below +35°F (+2°C).

Materials:Body: Die cast aluminiumBody covers: ABSBonnet: POM/AluminiumValve: PPElastomers: NBR

R82 — Excelon® Plus Modular System Pressure Regulators

1/4 4 to 145 (0.3 to 10) Knob 0 to 145 psi (0 to 10) 0.50 (0.23) R82G-2AK RMG3/8 4 to 145 (0.3 to 10) Knob 0 to 145 psi (0 to 10) 0.50 (0.23) R82G-3AK-RMG

Symbol Port Size Pressure range Adjustment Integrated gauge Weight lb (kg) Model *1 (PTF) psi (bar) psi (bar)

R82H–H H H– R H HOption selector *1)

SubstituteGR

Substitute23

SubstituteAG

SubstituteK

T*2)

FlowGeneral

Reverse FlowPort size

1/4“3/8“

ThreadformPTF

ISO G parallel Adjustment

Knob T-bar

Gauge Substitute With (fitted integrated gauge) G Without integrated gauge

N but with gauge port 1/8”

Pressure range *3) Substitute 4 to 58 psi (0.3 to 4 bar) F 4 to 145 psi (0.3 to 10 bar) M1 0 to 247 psi (0.7 to 17 bar) S*2)

*3) Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges.

*1) All models shown here are applicable for flow direction left to right. With flow direction right to left please use the online configurator www.imi-precision.com/air-preparation-configurator or contact Norgren.

*2) Units with 247 psi outlet pressure range are available only with the T-bar adjustment; therefore substitute T at the 7th position and S at the 9th position. T-bar handle only available with 247 psi option.

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2020 Norgren Ltd

01/20en us 8.105.855

Warning: Cancer and reproductive harm — www.p65warnings.ca.gov.

Flow characteristics

Inlet pressure: 145 psi (10 bar) Range: 4 to 145 psi (0.3 to 10 bar)Port size: 1/4”

Inlet pressure: 145 psi (10 bar) Range: 4 to 145 psi (0.3 to 10 bar)Port size: 3/8”

OU

TLET

PR

ESSU

RE

100

80

60

40

20

0

AIR FLOW

scfm

dm3/s

bar g

psig

0

2

4

6

0 20 40 60 70 80503010

0 10 20 30

OU

TLET

PR

ESSU

RE

100

80

60

40

20

0

AIR FLOW

scfm

dm3/s

bar g

psig

0

2

4

6

0 20 40 60 70 80503010

0 10 20 30

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2020 Norgren Ltd

01/20en us 8.105.855

Warning: Cancer and reproductive harm — www.p65warnings.ca.gov.

Accessories

820073-01KIT 820073-02KIT 820073-03KIT 820100-01KIT 820100-02KIT

Integrated gauge Integrated gauge Integrated gauge Gauge adaptor kit Gauge adaptor kit10 bar gauge 20 bar gauge 4 bar gauge 1/8 PTF R 1/8

820014-51KIT 820014-52KIT 820068-51KIT 820048-89KIT 820024-50KIT

Quikclamp® Quikclamp®with Neckmounting Panelmountingnut Mountingbracket bracketassembled bracketandpanelnut

page 4 page 4 page 5 page 5 page 5

820016-50KIT 840055-01KIT 840055-02KIT

Pressure sensing block Pressure sensing block Padlock Lockout device1/4 PTF G1/4

page 6 page 6

0860811000000000

page 7

Digital pressure switch51D (-14 to 145 psi)

820028-50KIT 820028-53KIT 0523109000000000 0881300000000000

Fullflowportingblock Fullflowportingblock Pressureswitchinterface Pneumaticpressureswitch3/8 PTF G3/8 block (18D pressure switch) 18D (7 to 120 psi) G1/4

page 6 page 6 page 6 page 6

FRLB82-Kit

Service KitR82 / B82Elastomerkit

(For regulators with gauge port instead of integrated port)

*3) primary scale

Gauges

0 to 84 0 to 6 0 to 0.6 2“ R1/8 18-015-012 0 to 145 0 to 10 0 to 1 2“ R1/8 18-015-013 0 to 362 0 to 25 0 to 2.5 2“ R1/8 18-015-014

Pressure range

(psi) (bar)*3) (MPa) ø Thread size Model

Center back connection, white face

*3) primary scale

Gauges

0 to 60 0 to 4 0 to 0.4 2“ 1/8“ NPT 18-015-202 0 to 160 0 to 11 0 to 1.1 2“ 1/8“ NPT 18-015-204 0 to 300 0 to 20 0 to 2.1 2“ 1/8“ NPT 18-015-205

Pressure range

(psi) *3) (bar) (MPa) ø Thread size Model

Center back connection, black face

820015-02KIT

Port Adaptors1/4 PTF

page 6

820015-03KIT

Port Adaptors3/8 PTF

page 6

820015-08KIT

Port AdaptorsG1/4

page 6

820015-09KIT

Port AdaptorsG3/8

page 6

820016-51KIT

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2020 Norgren Ltd

01/20en us 8.105.855

Warning: Cancer and reproductive harm — www.p65warnings.ca.gov.

Dimensions

Quikclamp® with wall bracket

AccessoriesQuikclamp®

Main ports 1/4”, 3/8”, (ISO G/PTF)

Gauge port Rc 1/8 for ISO G and 1/8 PTF for PTF main ports

1n

n2

2.3 (58.5)

1.7

(43.

0)

2.14

(54.

5)

4.07

(103

.3)

1.65

(42.

0)1.

53 (3

9.0)

1.5 (38.1)

.47 (12.1)

������

��� ��

���

������

��

��� ��

��

3.1

(78.

45)

1.4

(35.

65)

4.2

(105

.60)

1.4

(35.

65)

FLOW

1.8 (46.50)

2.2

(56.

00)

1.8 (46.50)

2.2

(56.

00)

1 1

21

1.85 (46.9) .47 (12.1)

1.7

(43.

1)

Dimensions in inches (mm) Projection/Third angle

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2020 Norgren Ltd

01/20en us 8.105.855

Warning: Cancer and reproductive harm — www.p65warnings.ca.gov.

Neckmountingbracket

Panelmountingnut

51

21

33

45

80 51

5746

68

71

58

8.9 15

47

15

58

36

57

66

4

18

29

31

05

58

36

15

2.7

32

53

2

2. 53

1.63

(41.

50)

.31

(8.0

)

Ø

4X FULL R

1.73 (44.0) 1.73 (44.0)

1.43 (36.5)1.43 (36.4)

R .86 (22.0)

1.01 (25.9)1.00 (25.5)

1.18 (30.0)

.36 (9.2) .07 (1.9)

.55 (14.0)

1.53 (38.9)

1.25 (32.0)

.55 (14.0)

.59 (15.0)

.31 (8.0)

.35 (9.0)

2x .35 (8.9)

2x .23 (6.0)

2x .28 (7.2)

.20 (5.2)

.19 (4.9)2X

2.1 (52.7)

.05 (1.52)

2.15

(54.

6)

1.1 (2

7.1)

1.1 (2

7.2)

1.46

(37.

0)

1.52

(38.

7)

2x .1 (2.68)

2x .24 (6.0)

2x .15 (3.7)

.21 (5.5)

.17 (4.3) 2x .83 (21.1).31 (8.0)

4x .39 (10.0)

4x .20(5.1)

2x .86 (22.0)

2x 1.0(26.2)

2x .12 (3.0)

1.94 (49.3)

.94 (23.8)

2x M4x0.7

8x FULL R

Mounting bracket

Dimensions in inches (mm) Projection/Third angle

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2020 Norgren Ltd

01/20en us 8.105.855

Warning: Cancer and reproductive harm — www.p65warnings.ca.gov.

Pressure sensing block Fullflowportingblock

2X 1.44 (36.6)

.88 (22.3)

1.76 (44.6)

1.97 (50.125).98 (25.12)

1.66 (42.25)

.72 (18.3)1.

5 (3

8.0)

.75 (19.0)

1.12 (28.6)

1.42 (36.0)

.19

(5)

1.18 (30)

1.18

(30)

1.77

(45)18

AC/

1.08 (27.5)

2.83 (72)

1.38 (35)

1.73 (44)

1.25 (32)

1.57

(40)

1.57 (40)

G1/4

Porting block for 18D pressure switch 18D Pressure switch

18DPortingblockand18Dassembled Pipe adaptor

.90 (23.00)

.46 (11.90)

.54 (13.85)

.51 (13.10)

.33 (8.40)

1.03 (26.20)

.45 (11.50)

1.73 (44)

1.26 (32)

1.57 (40)

2.24 (57)

G1/4

1.57

(40)

Dimensions in inches (mm) Projection/Third angle

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2020 Norgren Ltd

01/20en us 8.105.855

Warning: Cancer and reproductive harm — www.p65warnings.ca.gov.

51D Pressure switch - digital

11.8

(300

.0)

1.22

(31.

0)

1

3

56

4

7

1.22 (31.0)

G1/

8

1.43 (36.50)

1.18

(30.

0)

2

Switch OUT 1, green LED Switch OUT 2, red LED Dustproof protector Connector M12 x 1 Inlet port Alternative inlet port G1/8 plugged Thread for mounting screw

1

2

3

4

5

6

7

Dimensions in inches (mm) Projection/Third angle

WarningThese products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, Norgren Ltd.

Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure

modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure.

System designers must provide a warning to end users in the system instructio-nal manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.