r-rpp fix · 2019. 10. 18. · tors. fill gaps between boards using styro-fix. when fully cured,...

2
EXCELLENT ADHESION TO COMMON BUILDING SUBSTRATES AND INSULATING MATERIALS ONE CAN IS ENOUGH TO COVER 8-12 M 2 OF INSULATED SURFACE - HIGHLY EFFICIENT ONE CAN REPLACES 25 KG OF MORTAR FOR ETICS APPLICATIONS - SAVES TIME AND REDUCES THE INSULATION WEIGHT MADE COMPARED WITH TRADITIONAL METHODS WORKS AT LOW TEMPERATURES (-5 °C) – LONGER WORKING SEASONABLE APPLICATION HIGH INITIAL FORCE & EXCELLENT INSULATION - DOES NOT CREATE THERMAL OR ACOUSTIC BRIDGES * ETICS - External Thermal Insulation Composite System (ETICS) with foamed polystyrene usage RAWLPLUG LTD. Skibo Drive Thornliebank Industrial Estate Glasgow G46 8JR tel : +44 (0) 141 638 7961 fax: +44 (0) 141 638 7397 email: [email protected] web: www.rawlplug.co.uk APPLICATIONS Bonding insulation boards on facades and foundations Suitable for ETICS* systems with mechanical fixings Bonding and insulating of wall panels, roofing sheets & tiles Sealing gaps between foamed polystyrene Sealing cracks in walls Filling & sealing expansion joints in thermal insulation BASE MATERIALS Brick walls Hollow blocks Concrete Acrylic and mineral plasters Wood and Metal Foamed polystyrene PCV and rigid PUR foams and other insulation materials Features and benefits: ADHESIVE FOR THERMAL INSULATION BOARDS R-RPP FIX STYROFIX

Upload: others

Post on 06-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: R-RPP FIX · 2019. 10. 18. · tors. Fill gaps between boards using Styro-fix. When fully cured, the excess of adhesive should be removed (eg. using a knife). Remember! To use mechanical

EXCELLENT ADHESION TO COMMON BUILDING SUBSTRATES AND INSULATING MATERIALS

ONE CAN IS ENOUGH TO COVER 8-12 M2 OF INSULATED SURFACE - HIGHLY EFFICIENT

ONE CAN REPLACES 25 KG OF MORTAR FOR ETICS APPLICATIONS - SAVES TIME AND REDUCES THE INSULATION WEIGHT MADE COMPARED WITH TRADITIONAL METHODS

WORKS AT LOW TEMPERATURES (-5 °C) – LONGER WORKING SEASONABLE APPLICATION

HIGH INITIAL FORCE & EXCELLENT INSULATION - DOES NOT CREATE THERMAL OR ACOUSTIC BRIDGES

* ETICS - External Thermal Insulation Composite System (ETICS) with foamed polystyrene usage

RAWLPLUG LTD.Skibo DriveThornliebank Industrial EstateGlasgow G46 8JR

tel: +44 (0) 141 638 7961fax: +44 (0) 141 638 7397

email: [email protected]

web: www.rawlplug.co.uk

APPLICATIONS � Bonding insulation boards on facades

and foundations

� Suitable for ETICS* systems with mechanical fixings

� Bonding and insulating of wall panels, roofing sheets & tiles

� Sealing gaps between foamed polystyrene

� Sealing cracks in walls

� Filling & sealing expansion joints in thermal insulation

BASE MATERIALS � Brick walls

� Hollow blocks

� Concrete

� Acrylic and mineral plasters

� Wood and Metal

� Foamed polystyrene

� PCV and rigid PUR foams and other insulation materials

Features and benefits:

ADHESIVE FOR THERMAL INSULATION BOARDS

R-RPP FIXSTYROFIX

Page 2: R-RPP FIX · 2019. 10. 18. · tors. Fill gaps between boards using Styro-fix. When fully cured, the excess of adhesive should be removed (eg. using a knife). Remember! To use mechanical

Wide array of advantages Product Information Installation

and application:

2h - EXPRESS Application

Saves TIME & MONEY

EASY Application

EFFECTIVE12 m2 wall from one can

8-12 m2

EXTENDS Building Season

+30°C

-5°C

HIGH THERMAL Insulationλ≤ 0,036

1. Wear protective gloves. Ensure surfaces are free from dust, dirt, lime or grease. If the wall surface is dirty it must be primed.

2. Before adhering polystyrene board, starter track must be installed. Shake can vigorously for 30 seconds to mix properly components.

3. Optimal can temperature is +20°C. Appli-cation temperature from -5°C up to +30°C. Screw gun onto the can. Hold can upside--down during application.

4. For adhesion of foamed polystyrene facade insulation, apply a braid of Styrofix (approx. 3 cm wide) around the perimeter of polysty-rene boards (approx. 2 cm from the edge), with an additional strip across the centre of the board.

5. For adhesion of extruded polystyrene foam (XPS) on foundations, apply Styrofix in 4 vertical braids (approx. 3 cm wide) main-taining equal spacing of 20-30 cm between the strips. Ensure 3 cm clearance from the edge of the board (for boards wider than 100 cm, more braids should be applied).

6. Allow max. 5 minutes after application of Styrofix before mounting insulation to the facade or foundation. After mounting, add just the board to the desired position. Bo-ard adjustment is only possible for up to 10 minutes after adhesion. In the case of detachment from the surface apply again Styrofix.

7. At lintels and in the corners, support the boards (approx. 10-15 min) until the bond cures. After 2 hours the boards should be polished with an abrasive paper and additio-nally fixed with special mechanical connec-tors. Fill gaps between boards using Styro-fix. When fully cured, the excess of adhesive should be removed (eg. using a knife).

Remember!

� To use mechanical fixings for ETICS* systems

� To install the starter track

� Coverage depends on air humidity, temperature and type of application:

� up to 8 m2 for foamed polystyrene (EPS) on facade insulation

� up to 12 m2 for extruded polystyrene foam (XPS) on foundations

� Mechanical properties:

� Compressive strength ≥ 40 kPa

� Tensile strength ≥ 100 kPa

� Adhesion also to the substrate coated with bitumen ≥150 kPa

� You have about 5 minutes from applica-tion STYROfix to applying the board to the surface

� You have an additional 15 minutes for correction (without taking off the board from the wall. In case taking off the board required applying again STYROfix)

� 2 hours after application, the product is ready to fix to the special mechanical connectors

� To eliminate thermal bridges you can use STYROfix to fill gaps between boards

* ETICS - External Thermal Insulation Compo-site System (ETICS) with foamed polystyrene usage

STYROfix - Adhesive for thermal

insulation made of EPS / XPS