r p p r m - abb...level kv 380,650 750 1050 dimen- a 1686 a)1986 a) sions in mm b 1134 a)1434 a) c...

2
This document is issued by means of a computerized syste The digitally stored original is ele ctronically approved approved document has a date entered in the `Approved'-f A manual signature is not required. The information contained in this document has to kept strictly confidential. Any unautorized use, reproduction, distribution or disclosure to third parties are strictly forbidden. ABB reservs all rights regarding Intellectual Property Rights. © Copyright 2010 ABB. All rights reserved. 6917 028-PA(A4)Rev1 M M R R 255 27 30 50 D 470 600 111 205 C E 195 152 567 45 126 B 140 85 245 H 250 165 225 165 225 255 255 98 6 60 390 260 80 C/L Top flange 332 740 24x 15 710 30 C/L Diverter switch 520 165 165 490 K J 304 95 95 8x 1) 18 A 550 272 140 250 P P C/L Tap selector (2) 54920101-11 No. Shts. Document no. 1 9,13 Pos A Sheet no. Order Revision 82 UCG.E,T XXXX/900/III SHORT 2012-04-03 Henrik Sundberg Language Used in product Approved by Tap-Changer UCGR, UCGD 2012-03-08 Tomas Axelsson Take over department Modified by PPCO/TK 2012-03-05 Tomas Axelsson Title Responsible department Prepared INSULATIONSHORT VERSION LEVEL kV 380,650 750 1050 A 1686 a)1986 a) Dimen- sions in mm B 1134 a)1434 a) C 119 a)c) 119 a) D 240 c) 540 E 30 c) 36 H 930 c) 936 J 290 c) 293 K'580 c) 586 14 Diverter switch terminal 1) Holes for mounting of supports for cleats and leads 2) Shielding rings for insulation levels 650, 750 and 1050 only T=6 V-2,4..12 H-1,3..13 2) 21 20 650 Transformer flange Only for insulation level 1050 kV 4x 18 of which 2x att opposite side 1) 2) M-M These two holes also in top plate a) For mounting on active part use A+106,B and C+106 (See also Drawing 54920103-1) c) Not applicable for 380 kV R-R 2x 18 1)

Upload: others

Post on 23-Mar-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: R P P R M - ABB...LEVEL kV 380,650 750 1050 Dimen- A 1686 a)1986 a) sions in mm B 1134 a)1434 a) C 119 a)c)119 a) D 240 c)540 E 30 c) 36 H 930 c)936 J 290 c)293 K'580 c)586 14 Diverter

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

The information contained in this document has to kept strictly

confidential. Any unautorized use, reproduction, distribution

or disclosure to third parties are strictly forbidden.

ABB reservs all rights regarding Intellectual Property Rights.

© Copyright 2010 ABB. All rights reserved.

6917 028-PA(A4)Rev1

MM

R

R

255 27

30

50

D

470

600

111 205

C

E

195

152

567

45

126

B

14085

245

H

250

165

225

165

225

255 255

98

6

60390

260

80 C/L Top flange

332

740

24x 15

710

30 C/L Diverter switch

520

165 165

490

K

J

30495

95

8x 1)18

A

550

272

140 250

P P

C/L Tap selector

(2)54920101-11No. Shts.Document no.

19,13 PosA

Sheet no.OrderRevision

82 UCG.E,T XXXX/900/III SHORT2012-04-03Henrik Sundberg

LanguageUsed in productApproved by

Tap-Changer UCGR, UCGD2012-03-08Tomas Axelsson

Take over departmentModified by

PPCO/TK2012-03-05Tomas Axelsson

TitleResponsible departmentPrepared

INSULATIONSHORT VERSIONLEVEL kV 380,650

750 1050A 1686 a)1986 a)Dimen-

sionsin mm

B 1134 a)1434 a)C 119 a)c)119 a)D 240 c) 540E 30 c) 36H 930 c) 936J 290 c) 293K'580 c) 586

14 Diverter switch terminal

1) Holes for mounting of supports for cleats and leads2) Shielding rings for insulation levels 650, 750 and 1050 only

T=6

V-2,4..12

H-1,3..13

2)

2120

650

Transformer flange

Only for insulation level 1050 kV

4x 18 of which 2x att opposite side 1)

2)

M-M

These two holesalso in top plate

a) For mounting on active part use A+106,B+106 and C+106 (See also Drawing 54920103-1)c) Not applicable for 380 kV

R-R2x 18 1)

Page 2: R P P R M - ABB...LEVEL kV 380,650 750 1050 Dimen- A 1686 a)1986 a) sions in mm B 1134 a)1434 a) C 119 a)c)119 a) D 240 c)540 E 30 c) 36 H 930 c)936 J 290 c)293 K'580 c)586 14 Diverter

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

The information contained in this document has to kept strictly

confidential. Any unautorized use, reproduction, distribution

or disclosure to third parties are strictly forbidden.

ABB reservs all rights regarding Intellectual Property Rights.

© Copyright 2010 ABB. All rights reserved.

6917 028-PA(A4)Rev1

30�$

30�$

60�$

50�$

22,5�$

22,5�$

45�$

50�$

45

8

55

10

79

45 33,5

30

13

15

40

15

13

245 350

R263

R282.5

(2)54920101-11No. Shts.Document no.

29,13 PosA

Sheet no.OrderRevision

82 UCG.E,T XXXX/900/III SHORT2012-04-03Henrik Sundberg

LanguageUsed in productApproved by

Tap-Changer UCGR, UCGD2012-03-08Tomas Axelsson

Take over departmentModified by

PPCO/TK2012-03-05Tomas Axelsson

TitleResponsible departmentPrepared

ADDITIONAL DRAWINGS:Connection Diagrams:See Technical Guide UCMounting on active part: 54920103-1Accessories:54920103-2Motor Drive BUL:54830001-1Motor Drive BUE:54830001-2 or -3External Drive Shaft:54920083-4Pressure Relay:54920083-2Bevel Gear:54920083-1

T=14

Tap selector contact 20,21 and 22 with shields

9 positions

P-P

23

45

67

1

89

R282.5

R263

A

22

20

21

13 positions

P-P

23

45

67

89

1

1011

1213

22

20

21

Current collector

A