www.eaton.com Standard Features w Transformer 5000 provides isolation and step-down 120 VAC outlets w Multiple output receptacles: 120 VAC w Input power cable with L6-30P plug w Dip switch to select 208 or 240 VAC input w 2 — L5-20R protected by individual breakers. w 6 — L5-15R protected by two breakers (one breaker for 3 receptacles) Transformer 5000 Quick Start

Upload: phamkhanh

Post on 02-Jul-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

w w w . e a t o n . c o m

Standard Features w Transformer 5000 provides isolation and step-down 120 VAC outlets

w Multiple output receptacles: 120 VAC

w Input power cable with L6-30P plug

w Dip switch to select 208 or 240 VAC input

w 2 — L5-20R protected by individual breakers.

w 6 — L5-15R protected by two breakers (one breaker for 3 receptacles)

Transformer 5000Quick Start

STEP 1: Transformer 5000 Unpacking and Parts Check (87102)

Transformer 5000 Quick Start Manual

Transformer 5000 Box Contents

Tower Stand Extenders

Stabilizer Bracket(4 screws included)

Telescopic Railsfor Rack Mount

49

4554

43 51

STEP 2: Transformer 5000 Tower Configuration

Tower Configuration of Standard System with Transformer Module

1

1

22

44

4

4

3 3

Transformer 5000

MX 5000 RT

EXB RT(up to 3)

5

86-87102-00 A01 - Page 2

EX RT Transformer Module

STEP 3: Transformer 5000 Rack Configuration

LOAD 4 / 120V~,16A

LOAD 1120V~,16A

LOAD 2120V~,16A

SET THISSWITCH WHENUNPOWEREDBY ALL SOURCESINPUT VOLTAGESELECTION240~

208~

INPUTBREAKER

TRANSFORMERPROTECTION

LOAD 3 / 120V~,16A

LOAD 3BREAKER

LOAD 1BREAKER

LOAD 2BREAKER

LOAD 4BREAKER

LOAD 4 / 120V~,16A

LOAD 1120V~,16A

LOAD 2120V~,16A

SET THISSWITCH WHENUNPOWEREDBY ALL SOURCESINPUT VOLTAGESELECTION240~

208~

INPUTBREAKER

TRANSFORMERPROTECTION

LOAD 3 / 120V~,16A

LOAD 3BREAKER

LOAD 1BREAKER

LOAD 2BREAKER

LOAD 4BREAKER

LOAD 4 / 120V~,16A

LOAD 1

120V~,16A

LOAD 2

120V~,16A

SET THIS

SWITCH WHEN

UNPOWERED

BY ALL SOURCES

INPUT VOLTAGE

SELECTION

240~

208~

INPUT

BREAKER

TRANSFORMER

PROTECTION

LOAD 3 / 120V~,16A

LOAD 3

BREAKER

LOAD 1

BREAKER

LOAD 2

BREAKER

LOAD 1

120V~,16A

LOAD 2

120V~,16A

SET THIS

SWITCH WHEN

UNPOWERED

BY ALL SOURCES

INPUT VOLTAGE

SELECTION

240~

208~

INPUT

BREAKER

TRANSFORMER

PROTECTION

LOAD 1

BREAKER

LOAD 2

BREAKER

3

4

4

4

4 2

2 1

4

4

51

6 6

6

6

STEP 4: Transformer, UPS, and MX EXB RT Systems Connections

Transformer5000InputCableL6-30P

MX EXBBattery

MX EXBBattery

MX 5000 RTUPS

Transformer5000

15

1

17

19

See System Installation and User Manual for details and initial start-up procedures.

86-87102-00 A01 - Page 2

Quick Start

1. Attach both front mounting ear brackets to Transformer 5000 module with supplied screws (for this step, it is possible to adjust the position of both front mounting brackets).

2. Attach rear support brackets to module. These brackets prevent the Transformer 5000 module from sliding out of the rack.

3. Attach rails together and secure with wing nuts, and finger tighten both sides.

4. Attach both rails to rear and front of rack with supplied flathead screws (as shown).

The UPS may remain connected to AC source while installing the transformer.

1. Connect the transformer input cable L6-30P (17) to one of the UPS outlets L6-30R (1).

2. Connect the 120V load to the outlet of transformer (15) or (19).

Note: If an “RCD” load is connected to the transformer, the UPS may go into bypass mode, sound an alarm, and perform self diagnostics for 23 seconds before returning to normal operation.

5. Use caution when sliding unit into rack. Temporarily secure unit to rack with thumb screws on front mounting brackets.

6. Secure rear support brackets to rails.

www.eaton.com86-87102-00 A01