quick start guide - iron edison 3...mate3 inverter (master) inverter (slave) flexmax charge...
TRANSCRIPT
UP
PORT
TOP
LOCK
BATTERY STATUS
INVERTER
GEN
CHARGER
EVENTS
FAVORITE
AC INPUTOutBack Power
1.5 kW0.1 kW
115 V1.5 kW
85%
28.5 V
System OK
0.00 kW
0.0 kW
GG
About OutBack Power TechnologiesOutBack Power Technologies is a leader in advanced energy conversion technology. Our products include true sine wave inverter/chargers, maximum power point tracking charge controllers, and system communication components, as well as circuit breakers, batteries, accessories, and assembled systems.
Contact InformationTelephone: +1.360.435.6030 (Main)
+1.360.618.4363 (Technical Support)+1.360.435.6019 (Fax)
Mailing Address: Corporate Headquarters European Office17825 – 59th Avenue NE Hansastrasse 8Suite B D-91126Arlington, WA 98223 USA Schwabach, Germany
E-mail: [email protected]
Web Site: www.outbackpower.com
DisclaimerUNLESS SPECIFICALLY AGREED TO IN WRITING, OUTBACK POWER TECHNOLOGIES:
(a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION.
(b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER’S RISK.
Warranty SummaryOutBack Power Technologies warrants that the products it manufactures will be free from defects in materials and workmanship for a period of five (5) years subject to the conditions set forth in the warranty detail, found in the product manual.
OutBack Power Technologies cannot be responsible for system failure, damages, or injury resulting from improper installation of their products.
Notice of CopyrightMATE3 System Display and Controller Quick Start Guide © February 2012 by OutBack Power Technologies. All Rights Reserved.
TrademarksOutBack Power is a registered trademark of OutBack Power Technologies.
Date and RevisionFebruary 2012, Revision A
Part Number900-0136-01-00 Rev A
Quick Start Guide
Contents:Installation………………………………………..…….. 1-2Firmware Updating………………………………….…. 3-4User Panel……………...………………….…….……... 5Controls…………………………………………….……. 6Accessing the Main Menu……………….……….……. 7Configuration Wizard:
New Configuration……………………………...…. 9 Configuration Wizard (Save)………………..……. 10
Programming System
CONFIG Saved to SD Card
Continue
Setup Complete
Exit Program Save
System Programmed
Exit Save
CONFIG 1/07/11 19:58A 1/08/11 7:47
Exit New Save
M
ProgramSystem
Save to SD Card
M
M
New Wizard Configuration File Bxxxxxxx
Delete Save
Bxxxxxxx Saved to SD Card
Continue
C
File names can have up to 8 characters.
1
1
S
Press <Program>to program the
settings and commit them to the MATE3
internal memory.
Press <Save> to save the settings to the SD card.
Recommendation:1. Program the system first.
2. Then save the settings to the SD card for use or restoration in the future.
NOTE: Saving without programming the system first may result in the loss of settings.
In other words, changes made to settings may not be set in the internal memory and can be lost.
Programming the system commits the settings to internal memory.
Saving the profile to the SD card saves a copy of that profile onto the SD card so that it can be retrieved at a later time if required.
Programming and Saving the Configuration
Page 10
Press <New> to create a new name
for the settings.
Press <Save> to overwrite the settings in the filename that is highlighted in the list.
Installation – Direct Connections
Page 1
PV +
PV –
BAT–
BAT +
MATE Port
(RJ45)
RTS Port
(RJ11)
In 23.2 V 0.0 AOut 27.6 V 0.0 A
0.000 kW 0.0 kWHAUX: OFF Sleeping
MATE3 to FLEXmax Charge
Controller
MATE3
FLEXmax Charge Controller
(FM80)
MATE RTS
MATE3 to
Inverter
MATE3 Inverter
Installation – Indirect Connections
PV +
PV –
BAT–
BAT +
MATE Port
(RJ45)
RTS Port
(RJ11)
In 23.2 V 0.0 AOut 27.6 V 0.0 A
0.000 kW 0.0 kWHAUX: OFF Sleeping
MATE
RTS
1st
MATE1234
PV +
PV –
BAT–
BAT +
MATE Port
(RJ45)
RTS Port
(RJ11)
In 23.2 V 0.0 AOut 27.6 V 0.0 A
0.000 kW 0.0 kWHAUX: OFF Sleeping
MATE
RTS
1st
MATE12345678910
MATE
RTS
MATE3 to Communications Manager (HUB4 or HUB10)
MATE3 Inverter (Master)
Inverter (Slave)
FLEXmax Charge Controller
(FM80)
Communications Manager (HUB4) MATE3
Inverter
Communications Manager (HUB10)
To program the settings for the system on the MATE3, see the Programming section of the MATE3 Owner’s Manual.
To program the settings for the system on the MATE3, see the Programming section of the MATE3 Owner’s Manual.
Single Inverter
Stacked Inverters
FLEXmax Charge Controller
(FM80)
Page 2
Configuration Wizard
Page 9
Page 8
Home ScreenTo enter the
correct password:
Main Menu
When the correct password is displayed:
Press the <LOCK> Button.
Use the Control Wheel to change the password to 141.
Press the center button on the Control Wheel to
enter the password.
BATTERY STATUS
INVERTER
GEN
CHARGER
EVENTS
FAVORITE
AC INPUT
UP
PORT
TOP
LOCK
OutBack Power
0.0kW0.1kW115VG0.1 kW
13.6V
13.6VG
System OK
BATTERY STATUS
UP
PORT
TOP
LOCK
Installer [0] [0] [0] [0]
User[132]
INVERTER
GEN
CHARGER
EVENTS
FAVORITE
AC INPUT
132
BATTERY STATUS
UP
PORT
TOP
LOCK
Installer [0] [0] [0] [0]
User[132]
INVERTER
GEN
CHARGER
EVENTS
FAVORITE
AC INPUT
132
BATTERY STATUS
UP
PORT
TOP
LOCK
Settings >>Configuration Wizard >>Device Data Logs >>Event Logs >>Software Update >>
INVERTER
GEN
CHARGER
EVENTS
FAVORITE
AC INPUTSettings
To return to the Home Screen from the Main
Menu, press the <TOP>, <UP>, or <LOCK>
Buttons.
To return to the Main Menu: To return to the Main Menu:
Press the <TOP> button.Press the <TOP> button. Press the <UP> Button.
BATTERY STATUS
INVERTER
GEN
CHARGER
EVENTS
FAVORITE
AC INPUT
UP
PORT
TOP
LOCK
OutBack Power
0.0kW0.1kW
115VG
0.1 kW
13.6V
13.6V
System OK
Home Screen
Exiting the Main Menu:Main Menu Screen
Menu Item Menu ItemTo return to the Menu Options:
BATTERY STATUS
UP
PORT
TOP
LOCK
System >>Inverter >>Charge Controller >>Battery Monitor >>MATE >>
INVERTER
GEN
CHARGER
EVENTS
FAVORITE
AC INPUTSystem
Menu Options
BATTERY STATUS
UP
PORT
TOP
LOCK
System Information >>Date & Time >>LCD Display >>Sound >>Ethernet Addresses >>
INVERTER
GEN
CHARGER
EVENTS
FAVORITE
AC INPUTSystem Information
BATTERY STATUS
UP
PORT
TOP
LOCK
System Information >>Date & Time >>LCD Display >>Sound >>Ethernet Addresses >>
INVERTER
GEN
CHARGER
EVENTS
FAVORITE
AC INPUTSystem Information
Accessing the Main Menu:
See page 6 for instructions on adjusting set points within the Main Menu.
Page 3
www.outbackpower.com
or
Firmware Upgrades - Downloading
Click here to save the file to the SD card.
Continued on page 4.
11
2
2
3
3
Page 4
Firmware Upgrades – Installing on MATE3
Page 7
To return to the Main Menu, press the <TOP> button.
To return to the Home Screen from the Main Menu, press the <TOP>, <UP>, or <LOCK> buttons.
Main Menu Screen*
Home Screen
Menu Options
Menu Items Menu Items
To return to the Main Menu, press the <TOP> button.
To return to the Main Menu, press the <TOP> button.
*Accessing the Main menu requires entering a password.
See page 8 for details on how to access the Main menu.
Navigation
Ethernet Port
Port to HUB or OutBack
Device
Side View Back View
Page 5
SD Memory Card Slot
Network Status LEDs
Inverter Hot Key
Charger Hot Key
Gen(erator) Hot Key
Soft Keys (x4)
UP
PORT
TOP
LOCK
BATTERY STATUS
INVERTER
GEN
CHARGER
EVENTS
FAVORITE
AC INPUTOutBack Power
1.5 kW0.1 kW
115 V1.5 kW
85%
28.5 V
System OK
0.00 kW
0.0 kW
GG
Front View
Inverter Status LED
Charger Status LED
GEN Status LED
Events Hot KeyEvents Status LED
AC Input Hot Key
AC Input Status LED
Favorites Hot KeyFavorite Status LED
Battery Status LEDs (x3)
Liquid Cyrstal Display (LCD)
Front Cover
OutBack Power
1.5 kW1.5 kW
115 V1.5 kW
85%
28.5 V
System OK
0.00 kW
0.0 kW
GG
User Panel
Page 6
Adjust Set Point Mode
To Adjust Set Points:1. Use the Control Wheel to navigate to
the set point field to be adjusted. 2. When the desired set point is selected,
press the Enter button. The box around the field should become solid (Adjust Set Point mode).
3. Use the Control Wheel to change the set point value.
4. When the set point is correct, press the center button again to return to Field Select mode.
5. Repeat Steps 1-4 for each set point to be adjusted.
To scroll down to the next menu or increase the value of the setting:
While touching the control wheel, make a clockwise circle.
To scroll up to the previous menu or decrease the value of the setting:
While touching the control wheel, make a counter-clockwise circle.
To select the option or setting value:
Press the button in the center of the control wheel (Enter Button).
UP
PORT
TOP
LOCK
BATTERY STATUS
INVERTER
GEN
CHARGER
EVENTS
FAVORITE
AC INPUTOutBack Power
1.5 kW0.1 kW
115 V1.5 kW
85%
28.5 V
System OK
0.00 kW
0.0 kW
GG
TOP Navigation
Key
UP Navigation
KeyPORT
Navigation Key
Control Wheel
ENTER Button
LOCK Navigation
Key
OutBack Power
1.5 kW1.5 kW
115 V1.5 kW
85%
28.5 V
System OK
0.00 kW
0.0 kW
GG
Programming Controls
Field Select Mode