quick start guide - iron edison 3...mate3 inverter (master) inverter (slave) flexmax charge...

6
UP PORT TOP LOCK BATTERY STATUS INVERTER GEN CHARGER EVENTS FAVORITE AC INPUT OutBack Power 1.5 kW 0.1 kW 115 V 1.5 kW 85% 28.5 V System OK 0.00 kW 0.0 kW G G About OutBack Power Technologies OutBack Power Technologies is a leader in advanced energy conversion technology. Our products include true sine wave inverter/chargers, maximum power point tracking charge controllers, and system communication components, as well as circuit breakers, batteries, accessories, and assembled systems. Contact Information Telephone: +1.360.435.6030 (Main) +1.360.618.4363 (Technical Support) +1.360.435.6019 (Fax) Mailing Address: Corporate Headquarters European Office 17825 – 59 th Avenue NE Hansastrasse 8 Suite B D-91126 Arlington, WA 98223 USA Schwabach, Germany E-mail: [email protected] Web Site: www.outbackpower.com Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING, OUTBACK POWER TECHNOLOGIES: (a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION. (b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER’S RISK. Warranty Summary OutBack Power Technologies warrants that the products it manufactures will be free from defects in materials and workmanship for a period of five (5) years subject to the conditions set forth in the warranty detail, found in the product manual. OutBack Power Technologies cannot be responsible for system failure, damages, or injury resulting from improper installation of their products. Notice of Copyright MATE3 System Display and Controller Quick Start Guide © February 2012 by OutBack Power Technologies. All Rights Reserved. Trademarks OutBack Power is a registered trademark of OutBack Power Technologies. Date and Revision February 2012, Revision A Part Number 900-0136-01-00 Rev A Quick Start Guide Contents: Installation………………………………………..…….. 1-2 Firmware Updating………………………………….…. 3-4 User Panel……………...………………….…….……... 5 Controls…………………………………………….……. 6 Accessing the Main Menu……………….……….……. 7 Configuration Wizard: New Configuration……………………………...…. 9 Configuration Wizard (Save)………………..……. 10

Upload: others

Post on 11-Jun-2020

21 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Quick Start Guide - Iron Edison 3...MATE3 Inverter (Master) Inverter (Slave) FLEXmax Charge Controller (FM80) Communications Manager (HUB4) MATE3 Inverter Communications Manager (HUB10)

UP

PORT

TOP

LOCK

BATTERY STATUS

INVERTER

GEN

CHARGER

EVENTS

FAVORITE

AC INPUTOutBack Power

1.5 kW0.1 kW

115 V1.5 kW

85%

28.5 V

System OK

0.00 kW

0.0 kW

GG

About OutBack Power TechnologiesOutBack Power Technologies is a leader in advanced energy conversion technology. Our products include true sine wave inverter/chargers, maximum power point tracking charge controllers, and system communication components, as well as circuit breakers, batteries, accessories, and assembled systems.

Contact InformationTelephone: +1.360.435.6030 (Main)

+1.360.618.4363 (Technical Support)+1.360.435.6019 (Fax)

Mailing Address: Corporate Headquarters European Office17825 – 59th Avenue NE Hansastrasse 8Suite B D-91126Arlington, WA 98223 USA Schwabach, Germany

E-mail: [email protected]

Web Site: www.outbackpower.com

DisclaimerUNLESS SPECIFICALLY AGREED TO IN WRITING, OUTBACK POWER TECHNOLOGIES:

(a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION.

(b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER’S RISK.

Warranty SummaryOutBack Power Technologies warrants that the products it manufactures will be free from defects in materials and workmanship for a period of five (5) years subject to the conditions set forth in the warranty detail, found in the product manual.

OutBack Power Technologies cannot be responsible for system failure, damages, or injury resulting from improper installation of their products.

Notice of CopyrightMATE3 System Display and Controller Quick Start Guide © February 2012 by OutBack Power Technologies. All Rights Reserved.

TrademarksOutBack Power is a registered trademark of OutBack Power Technologies.

Date and RevisionFebruary 2012, Revision A

Part Number900-0136-01-00 Rev A

Quick Start Guide

Contents:Installation………………………………………..…….. 1-2Firmware Updating………………………………….…. 3-4User Panel……………...………………….…….……... 5Controls…………………………………………….……. 6Accessing the Main Menu……………….……….……. 7Configuration Wizard:

New Configuration……………………………...…. 9 Configuration Wizard (Save)………………..……. 10

Page 2: Quick Start Guide - Iron Edison 3...MATE3 Inverter (Master) Inverter (Slave) FLEXmax Charge Controller (FM80) Communications Manager (HUB4) MATE3 Inverter Communications Manager (HUB10)

Programming System

CONFIG Saved to SD Card

Continue

Setup Complete

Exit Program Save

System Programmed

Exit Save

CONFIG 1/07/11 19:58A 1/08/11 7:47

Exit New Save

M

ProgramSystem

Save to SD Card

M

M

New Wizard Configuration File Bxxxxxxx

Delete Save

Bxxxxxxx Saved to SD Card

Continue

C

File names can have up to 8 characters.

1

1

S

Press <Program>to program the

settings and commit them to the MATE3

internal memory.

Press <Save> to save the settings to the SD card.

Recommendation:1. Program the system first.

2. Then save the settings to the SD card for use or restoration in the future.

NOTE: Saving without programming the system first may result in the loss of settings.

In other words, changes made to settings may not be set in the internal memory and can be lost.

Programming the system commits the settings to internal memory.

Saving the profile to the SD card saves a copy of that profile onto the SD card so that it can be retrieved at a later time if required.

Programming and Saving the Configuration

Page 10

Press <New> to create a new name

for the settings.

Press <Save> to overwrite the settings in the filename that is highlighted in the list.

Installation – Direct Connections

Page 1

PV +

PV –

BAT–

BAT +

MATE Port

(RJ45)

RTS Port

(RJ11)

In 23.2 V 0.0 AOut 27.6 V 0.0 A

0.000 kW 0.0 kWHAUX: OFF Sleeping

MATE3 to FLEXmax Charge

Controller

MATE3

FLEXmax Charge Controller

(FM80)

MATE RTS

MATE3 to

Inverter

MATE3 Inverter

Page 3: Quick Start Guide - Iron Edison 3...MATE3 Inverter (Master) Inverter (Slave) FLEXmax Charge Controller (FM80) Communications Manager (HUB4) MATE3 Inverter Communications Manager (HUB10)

Installation – Indirect Connections

PV +

PV –

BAT–

BAT +

MATE Port

(RJ45)

RTS Port

(RJ11)

In 23.2 V 0.0 AOut 27.6 V 0.0 A

0.000 kW 0.0 kWHAUX: OFF Sleeping

MATE

RTS

1st

MATE1234

PV +

PV –

BAT–

BAT +

MATE Port

(RJ45)

RTS Port

(RJ11)

In 23.2 V 0.0 AOut 27.6 V 0.0 A

0.000 kW 0.0 kWHAUX: OFF Sleeping

MATE

RTS

1st

MATE12345678910

MATE

RTS

MATE3 to Communications Manager (HUB4 or HUB10)

MATE3 Inverter (Master)

Inverter (Slave)

FLEXmax Charge Controller

(FM80)

Communications Manager (HUB4) MATE3

Inverter

Communications Manager (HUB10)

To program the settings for the system on the MATE3, see the Programming section of the MATE3 Owner’s Manual.

To program the settings for the system on the MATE3, see the Programming section of the MATE3 Owner’s Manual.

Single Inverter

Stacked Inverters

FLEXmax Charge Controller

(FM80)

Page 2

Configuration Wizard

Page 9

Page 4: Quick Start Guide - Iron Edison 3...MATE3 Inverter (Master) Inverter (Slave) FLEXmax Charge Controller (FM80) Communications Manager (HUB4) MATE3 Inverter Communications Manager (HUB10)

Page 8

Home ScreenTo enter the

correct password:

Main Menu

When the correct password is displayed:

Press the <LOCK> Button.

Use the Control Wheel to change the password to 141.

Press the center button on the Control Wheel to

enter the password.

BATTERY STATUS

INVERTER

GEN

CHARGER

EVENTS

FAVORITE

AC INPUT

UP

PORT

TOP

LOCK

OutBack Power

0.0kW0.1kW115VG0.1 kW

13.6V

13.6VG

System OK

BATTERY STATUS

UP

PORT

TOP

LOCK

Installer [0] [0] [0] [0]

User[132]

INVERTER

GEN

CHARGER

EVENTS

FAVORITE

AC INPUT

132

BATTERY STATUS

UP

PORT

TOP

LOCK

Installer [0] [0] [0] [0]

User[132]

INVERTER

GEN

CHARGER

EVENTS

FAVORITE

AC INPUT

132

BATTERY STATUS

UP

PORT

TOP

LOCK

Settings >>Configuration Wizard >>Device Data Logs >>Event Logs >>Software Update >>

INVERTER

GEN

CHARGER

EVENTS

FAVORITE

AC INPUTSettings

To return to the Home Screen from the Main

Menu, press the <TOP>, <UP>, or <LOCK>

Buttons.

To return to the Main Menu: To return to the Main Menu:

Press the <TOP> button.Press the <TOP> button. Press the <UP> Button.

BATTERY STATUS

INVERTER

GEN

CHARGER

EVENTS

FAVORITE

AC INPUT

UP

PORT

TOP

LOCK

OutBack Power

0.0kW0.1kW

115VG

0.1 kW

13.6V

13.6V

System OK

Home Screen

Exiting the Main Menu:Main Menu Screen

Menu Item Menu ItemTo return to the Menu Options:

BATTERY STATUS

UP

PORT

TOP

LOCK

System >>Inverter >>Charge Controller >>Battery Monitor >>MATE >>

INVERTER

GEN

CHARGER

EVENTS

FAVORITE

AC INPUTSystem

Menu Options

BATTERY STATUS

UP

PORT

TOP

LOCK

System Information >>Date & Time >>LCD Display >>Sound >>Ethernet Addresses >>

INVERTER

GEN

CHARGER

EVENTS

FAVORITE

AC INPUTSystem Information

BATTERY STATUS

UP

PORT

TOP

LOCK

System Information >>Date & Time >>LCD Display >>Sound >>Ethernet Addresses >>

INVERTER

GEN

CHARGER

EVENTS

FAVORITE

AC INPUTSystem Information

Accessing the Main Menu:

See page 6 for instructions on adjusting set points within the Main Menu.

Page 3

www.outbackpower.com

or

Firmware Upgrades - Downloading

Click here to save the file to the SD card.

Continued on page 4.

11

2

2

3

3

Page 5: Quick Start Guide - Iron Edison 3...MATE3 Inverter (Master) Inverter (Slave) FLEXmax Charge Controller (FM80) Communications Manager (HUB4) MATE3 Inverter Communications Manager (HUB10)

Page 4

Firmware Upgrades – Installing on MATE3

Page 7

To return to the Main Menu, press the <TOP> button.

To return to the Home Screen from the Main Menu, press the <TOP>, <UP>, or <LOCK> buttons.

Main Menu Screen*

Home Screen

Menu Options

Menu Items Menu Items

To return to the Main Menu, press the <TOP> button.

To return to the Main Menu, press the <TOP> button.

*Accessing the Main menu requires entering a password.

See page 8 for details on how to access the Main menu.

Navigation

Page 6: Quick Start Guide - Iron Edison 3...MATE3 Inverter (Master) Inverter (Slave) FLEXmax Charge Controller (FM80) Communications Manager (HUB4) MATE3 Inverter Communications Manager (HUB10)

Ethernet Port

Port to HUB or OutBack

Device

Side View Back View

Page 5

SD Memory Card Slot

Network Status LEDs

Inverter Hot Key

Charger Hot Key

Gen(erator) Hot Key

Soft Keys (x4)

UP

PORT

TOP

LOCK

BATTERY STATUS

INVERTER

GEN

CHARGER

EVENTS

FAVORITE

AC INPUTOutBack Power

1.5 kW0.1 kW

115 V1.5 kW

85%

28.5 V

System OK

0.00 kW

0.0 kW

GG

Front View

Inverter Status LED

Charger Status LED

GEN Status LED

Events Hot KeyEvents Status LED

AC Input Hot Key

AC Input Status LED

Favorites Hot KeyFavorite Status LED

Battery Status LEDs (x3)

Liquid Cyrstal Display (LCD)

Front Cover

OutBack Power

1.5 kW1.5 kW

115 V1.5 kW

85%

28.5 V

System OK

0.00 kW

0.0 kW

GG

User Panel

Page 6

Adjust Set Point Mode

To Adjust Set Points:1. Use the Control Wheel to navigate to

the set point field to be adjusted. 2. When the desired set point is selected,

press the Enter button. The box around the field should become solid (Adjust Set Point mode).

3. Use the Control Wheel to change the set point value.

4. When the set point is correct, press the center button again to return to Field Select mode.

5. Repeat Steps 1-4 for each set point to be adjusted.

To scroll down to the next menu or increase the value of the setting:

While touching the control wheel, make a clockwise circle.

To scroll up to the previous menu or decrease the value of the setting:

While touching the control wheel, make a counter-clockwise circle.

To select the option or setting value:

Press the button in the center of the control wheel (Enter Button).

UP

PORT

TOP

LOCK

BATTERY STATUS

INVERTER

GEN

CHARGER

EVENTS

FAVORITE

AC INPUTOutBack Power

1.5 kW0.1 kW

115 V1.5 kW

85%

28.5 V

System OK

0.00 kW

0.0 kW

GG

TOP Navigation

Key

UP Navigation

KeyPORT

Navigation Key

Control Wheel

ENTER Button

LOCK Navigation

Key

OutBack Power

1.5 kW1.5 kW

115 V1.5 kW

85%

28.5 V

System OK

0.00 kW

0.0 kW

GG

Programming Controls

Field Select Mode