quadrupole magnetic design for an electron ion collider

24
Quadrupole Magnetic Design for an Electron Ion Collider Paul Brindza May 19, 2008

Upload: minya

Post on 08-Jan-2016

20 views

Category:

Documents


3 download

DESCRIPTION

Quadrupole Magnetic Design for an Electron Ion Collider. Paul Brindza May 19, 2008. Achieving Small Crossing Angles. Achieving small crossing angles requires a creative sharing of space inside SC quads with the nearby Ion or Electron beams - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Quadrupole Magnetic Design for an Electron Ion Collider

Quadrupole Magnetic Design for an Electron Ion Collider

Paul Brindza

May 19, 2008

Page 2: Quadrupole Magnetic Design for an Electron Ion Collider

Achieving Small Crossing Angles

• Achieving small crossing angles requires a creative sharing of space inside SC quads with the nearby Ion or Electron beams

• It seems advantageous to place the smaller lower field final focus electron quads closest to the interaction point

• Realistic design considerations of SC quads drives solutions where the ions or electrons must pass through the quad force collar or cold yoke structures

Page 3: Quadrupole Magnetic Design for an Electron Ion Collider

Electron Quad Design Choices

• Reaching small crossing angles requires a “hole” in the SC magnet structure to pass the Ion beam

• A “traditional” Cosine 2 Θ Quad with a non- magnetic force collar near the coil has residual field along the Ion trajectory

• Due to lower fields in the Electron Quad the iron yoke/force collar can be adjacent to the coil

Page 4: Quadrupole Magnetic Design for an Electron Ion Collider

Ion Quad

• Cosine 2Θ type SC quad operating at 2 Kelvin due to high field and high current density

• Non magnetic force collar adjacent to coil

• Hole to pass Electron beam in cold yoke or in force collar with a magnetic shield

• Magnetic Design was performed with TOSCA

Page 5: Quadrupole Magnetic Design for an Electron Ion Collider

Electron Quad Ion Quad

Gradient 64 T/M 220 T/M

Integral Gradient 73.7 (T/M)M 248 (T/M)M

EFL 1.15 M 1.13 M

Diameter 5 cm. 6 cm

Coil Length 120 cm 120 cm

Pressure on Force Collar 1060 psi 6370 psi

Average Current Density 15,000 Amps/cm^2 37,000 Amps/cm^2

Amp Turns 207,000 Amp turns 2 x 10^6 Amp-turns

Operating Current 3500 Amps 6000 Amps

Max field in coil 2 T 8 T

Operating Temperature 4.5 K 2 K

Yoke Length 130 cm 130 cm

Stored Energy 6.3 KJ 434 KJ

Inductance 1 mH 24 mH

Properties of Electron and Ion Quads

Page 6: Quadrupole Magnetic Design for an Electron Ion Collider

Head on View of Electron QuadTosca Model

Page 7: Quadrupole Magnetic Design for an Electron Ion Collider

Model tipped by 19 mR

Page 8: Quadrupole Magnetic Design for an Electron Ion Collider

Gradient in Electron Quad64 T/m and 72 (T/M)M

Page 9: Quadrupole Magnetic Design for an Electron Ion Collider

Harmonics for E quad

Page 10: Quadrupole Magnetic Design for an Electron Ion Collider

Field in Ion pass thru hole

Page 11: Quadrupole Magnetic Design for an Electron Ion Collider

Field in Ion pass thru hole

Page 12: Quadrupole Magnetic Design for an Electron Ion Collider

The Ion Quad for the Electron Light Ion Collider

Page 13: Quadrupole Magnetic Design for an Electron Ion Collider

Ion Quad Considerations• High Gradient of 220 T/m , high current

density 37KA/cm^2 and 8Tesla fields require operation at or near 2 Kelvin

• This permits use of NbTi SC cable

• Conventional Cosine 2Θ magnet geometry

• LHC experience with high gradient quads will be a valuable guide for design

• Force collar pressure due to magnetic forces is 6370 psi

Page 14: Quadrupole Magnetic Design for an Electron Ion Collider

Cross section of quad with electron pass thru

Page 15: Quadrupole Magnetic Design for an Electron Ion Collider

Field magnitude in coil and force collar

Page 16: Quadrupole Magnetic Design for an Electron Ion Collider

Gradient of Ion quad220 T/M and Integral G.dL = 250 (T/M)M

Page 17: Quadrupole Magnetic Design for an Electron Ion Collider

Plot of By on 2.5 cm radius in main aperture

Page 18: Quadrupole Magnetic Design for an Electron Ion Collider

Field harmonics in Ion quad

Page 19: Quadrupole Magnetic Design for an Electron Ion Collider

Field Magnitude in cold yoke

Page 20: Quadrupole Magnetic Design for an Electron Ion Collider

Integral By.dL along length of electron pass thru (8,000 gauss cm)

Page 21: Quadrupole Magnetic Design for an Electron Ion Collider

Field in electron pass thru By component

Page 22: Quadrupole Magnetic Design for an Electron Ion Collider

Harmonics of By on 1.3 radius in electron pass thru

Page 23: Quadrupole Magnetic Design for an Electron Ion Collider

Ion Quad Peak Field Load Lineand NbTi SC Cable Short Sample Curve

SSC outer cable used for comparison

Page 24: Quadrupole Magnetic Design for an Electron Ion Collider

Conclusions• Lambertson type quads are feasible for

the final focus magnets for ELIC

• Locating the Electron quads closest to the crossing point allows a smaller crossing angle.

• ELIC quads require beam pass thru holes in the quad structural elements

• NbTi SC cables can be used in the ELIC quads however the Ion quads must operate at 2 kelvin