quad sym technology lens dynamics, inc. wheat ridge, co
TRANSCRIPT
QUAD SYM TECHNOLOGY
Lens Dynamics, Inc.
Wheat Ridge, CO
QUAD SYM TECHNOLOGY
• Based on Quadrant Specific Technology.
• Can be the entire B.C. radii in one quadrant or just in the edge.
• Is it the full piece of the pie or just the crust?
DEFINE QUADRANTS
• Quadrant (Quad) 1 is from 1:30 to 4:30
• Quadrant (Quad) 2 is from 10:30 to 1:30
• Quadrant (Quad) 3 is from 7:30 to 10:30
• Quadrant (Quad) 4 is from 4:30 to 7:30
QUAD SYM B.C. DESIGN
• Entire piece of the pie or quadrant.
• Allows the lens to have up to 4 different base curves.
• The lathe cuts a proper front radii to achieve correct power.
QUAD SYM P.C. DESIGN
• Just the edge or crust.
• Allows for different edge lifts in all 4 quadrants.
• Helpful with edge standoff at 6 o’clock.
• Several steps flatter or steeper from Standard edge lift available.
• Quad Sym B.C. and Quad Sym P.C. designs can be combined when needed.
HOW TO FIT
• Start with a spherical large trial lens – Dyna Intra-Limbal.
• Align at least one quadrant and do over refraction.
• Document the fluorescein pattern in other quadrants.i.e. Are the other quadrants pooled or touching?
• Provide topography.• Lab will design other quadrants based on this
information
LATHE LIMITATIONS
• Larger diameters cannot be lathed much steeper B.C. than 5.80 mm.
• 2.0 mm of spread in B.C.s is maximum.
• Some lenses will need to be smaller to achieve needed B.C.s.
i.e. 10.2 mm to 10.8 mm diameters
FLUORESCEIN EVALUATION
TOPOGRAPHY
• Quad 1 and 4 are steep at 50.00 D. or 6.75 mm.
• Quad 2 is moderate at 47.00 D. or 7.18 mm.
• Quad 3 is Flat at 40.00 D. or 8.44 mm.
HOW TO FIT
• Start with 1 D. flatter than one quadrant.
i.e. Quad 3 is 40.00 D. + 1 D. flatter = 39.00 D./ 8.65 mm.
• Quad 1 is 49.00 D. + 1 D. flatter = 48.00 D./ 6.89 mm.
• Get best alignment in a quadrant. The other quadrants will be steepened or flattened per topography by the lab.
• Note the pooling or touch in the other quadrants. •Do over refraction.
Regular Dyna Intra-Limbal on eye
Sphere on eye Quad-Sym on eye
WHAT THE ORDER LOOKS LIKE
• Base Curve: Quad Sym B.C. design.
Q1 & 4 = 49.00, Q2 = 46.00, Q3 = 39.00
• Power: From trial fit 39:00, Total Power = -6.00
• Diameter: 11.2 with 9.4 OZ
• Edge: Standard Lift
QUAD SYM P.C. DESIGN
• Trial fit with large diameter lens – Dyna Intra-Limbal• Fit with standard spherical B.C. but fitter sees edge
problems.• Increase or decrease edge lift in each quadrant as
needed.
i.e. Trial of 7.50, -3.00, 11.2/9.4 fits well except there is pinch off at 12:00 o’clock and standoff at 6:00 o’clock.
• Order: 7.50, -3.00, 11.2 / 9.4, Quad Sym P.C. of Quad 1 & 3 = Standard, Quad 2 = 2 steps Flat, Quad 4 = 4 steps Steep.
QUAD SYM P.C. DESIGN
B.C. 7.50Pwr: -3.00Dia: 11.2 with 9.4 OZEdge Lift: Standard
B.C. 7.50Pwr: -3.00Dia. 11.2 with 9.4 OZEdge Lift: Q1 & 3 = StandardQ2 = 2 steps Flat, Q4 = 4 steps steep
Trial Lens Rx Lens
Questions?
Lens Dynamics, Inc.