qrics iso mechanical c 0131

12
^ * t NABL National Accreditation Board for Testing and Calibration Laboratories Department of Science & Technology, India CERTIFICATE OF ACCREDITATION QRICS CALIBRATION LABORATORIES PVT. LTD. has been assessed and accredited in accordance with the standard ISO/IEC 17025:2005 "General Rquirements for the Competence of Testing & Calibration Laboratories" for its facilities at 'PARAS' Complex, GP/67, Office No. 7,8 & 9 Basement, Thermax Ctiowk, MIDC, Chinchwad, Pune in the discipline of MECHANICAL CALIBRATION (To see the scope of accreditation of this laboratory, you may also visit NABL website www.nabl-india.org) Certificate Number C-0131 Issue Date 28/06/2012 Valid Until 27/06/2014 This certificate remains valid for the Scope of Accreditation as specified in the annexure subject to continued satisfactory compliance to the above standard & the additional requirements of NABL. Signed for and on behalf of NABL Shallv Sharma Anil Relia Dr T Ramasami

Upload: sachindesai055

Post on 20-Jan-2015

529 views

Category:

Documents


3 download

DESCRIPTION

 

TRANSCRIPT

  • 1. ^ * t NABL National Accreditation Board for Testing and Calibration Laboratories Department of Science & Technology, India CERTIFICATE OFACCREDITATION QRICS CALIBRATION LABORATORIES PVT. LTD. hasbeenassessedandaccreditedinaccordancewiththestandard ISO/IEC17025:2005 "GeneralRquirementsfortheCompetenceofTesting&CalibrationLaboratories" for itsfacilitiesat 'PARAS' Complex, GP/67, Office No.7,8&9 Basement,Thermax Ctiowk, MIDC,Chinchwad, Pune inthe disciplineof MECHANICAL CALIBRATION (To see the scope of accreditation of this laboratory, you may also visit NABL website www.nabl-india.org) Certificate Number C-0131 Issue Date 28/06/2012 Valid Until 27/06/2014 This certificateremains valid for the Scope of Accreditation as specified in the annexure subject to continued satisfactory compliance to the above standard &the additional requirements of NABL. Signed for and on behalf of NABL Shallv Sharma Anil Relia Dr T Ramasami

2. www.nabl-india.org * ITRT 3. "*,. Laboratory NflBL Deportment of Science a Technology, India SCOPE OF ACCREDITATION QRICS Calibration Laboratories Pvt.Ltd.,' Paras' Complex, GP/67, Office No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune Accreditation Standard ISO/I EC 17025:2005 Discipline Mechanical Calibration Certificate Number C-0131 Last Amended on 06.05.2013 Issue Date 28.06.2012 r Valid Until 27.06.2014 ' Page 1of10 Quantity Measured/ Instrument Range I Frequency "Calibration Measurement Capability () Remarks 1. EXTERNAL MICROMETER ' L.C. 0.001mm L.C. 0.01mm 2. CALIPER' (Digital/ Dial/ Electronic) L.C. 0.01mm | (Vernier & Dial) I L.C.0.02 mm I 3. VERNIER DEPTH' (Digital Type) L.C. 0.01mm (Vernier Type) L.C. 0.02mm Upto 100 mm Upto 100mm Upto 300 mm Upto 600 mm Upto 900 mm Upto 1000mm Upto 300 mm Upto 600 mm Upto 1000 mm Upto 300 mm Upto 600 mm Upto 1000mm Upto 300 mm Upto 600 mm Upto 300 mm Upto 600 mm 2.0 urn 6.5 u,m 10.19 ^m 11.0 (am 12.0 (im 13.0 (am 10.4 jam 10.5 pm 17.6 urn 16.7 (im 16.8 urn 19.5 urn 12.9 urn 14.8 urn 18.4 urn 19.8 urn Using Slip Gauge Blocks Using Slip Gauge Blocks & Plunger Dial Using Caliper Checker & Length Bar Using Caliper Checker & Length Bar Using Caliper Checker & Slip Gauges 4. Laboratory MflBL Department offScience a Technology. India SCOPE OF ACCREDITATION QRICS Calibration Laboratories Pvt. Ltd.,' Paras' Complex, GP/67, Office No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune Accreditation Standard ISO/IEC 17025:2005 Discipline Mechanical Calibration Certificate Number C-0131 Last Amended on 06.05.2013 Issue Date 28.06.2012 Valid Until 27.06.2014 Page 2 of 10 Quantity Measured/ Instrument Range/ Frequency "Calibration Measurement Capability () Remarks HEIGHT GAUGE ' (Digital/Dial/Electronic) L.C. 0.01mm L.C. 0.02mm ELECTRONIC HEIGHT GAUGE3 L.C. 0.001mm Linear Squareness DEPTH MICROMETER' L.C. 0.001mm L.C. 0.01mm HEIGHT MICROMETER' L.C. 0.002 mm Upto 300 mm Upto 600 mm Upto 1000 mm Upto 300 mm Upto 600 mm Upto 1000 mm Upto 600 mm Upto 600 mm Upto 600 mm Upto 100 mm Upto 100mm 300mm 11.3 urn 11.3 urn 14.8 urn 17.5 urn 17.6 (am 19.4 urn 5.6 um 6.6 (am 11.0 urn 11.5 jam 12.0 urn 7.0 Using Caliper Checker & Length Bar Using Slip Gauges & Cylinder Square Using Analog Comparator & Electronic Height Gauge Using Slip Gauges Using Lever Dial, Slip Gauges &Surfaceplate 5. NflBL Laboratory Department of Science fi Technology, Indiq SCOPE OF ACCREDITATION QRICS Calibration Laboratories Pvt. Ltd.,' Paras' Complex, GP/67, Office No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune Accreditation Standard ISO/IEC 17025:2005 Discipline Mechanical Calibration Certificate Number C-0131 Last Amended on 06.05.2013 Issue Date 28.06.2012 Valid Until 27.06.2014 Page 3 of 10 I 1 I I 8. 9. 10. Quantity Measured/ Instrument INTERNAL MICROMETER ' L.C. 0.01mm PLUNGER DIAL ' L.C. 0.001 mm L.C. 0.01 mm LEVER DIAL ' L.C. 0.001 mm L.C. 0.002 mm Range / Frequency Upto 25 mm Upto 10 mm Upto 50 mm Upto 50 mm 0.14 mm 0.2mm "Calibration Measurement Remarks j Capability () 1 6.5 um 2.6 (im 3.2 (im 7.0 urn 2.6 ^m 3.1 um i1 Using Plunger Dial & Slip 1 Gauges i ! Using Electronic Probe 1 Using Dial Calibration Tester I i Using ElectronicProbe ', $ L.C. 0.01 mm 11. DIAL THICKNESS GAUGEl L.C. 0.01 mm 12. PLAIN PLUG GAUGES/ CYLINDRICAL OD/ PIN1 13. SNAP GAUGE/ LENGTH GAUGE1 I mm Upto 20 mm Upto0 150mm Upto 0 300 mm Upto 300 mm 300 to 500 mm 7.0 urn 6.0 um 2.7 urn 3.4 um 3.2 urn 9.2 (am Using Dial Calibration Tester Using Slip Gauges Using Plunger Dial & Slip '. Gauges Using Slip Gauges ' 3 Using ElectronicHeight f Gauge ! 6. NflBL Laboratory Department offScience a Technology, Indio SCOPE OF ACCREDITATION QRICS Calibration Laboratories Pvt. Ltd.,' Paras' Complex, GP/67, Office No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune Accreditation Standard ISO/IEC 17025:2005 Discipline Mechanical Calibration Certificate Number C-0131 Last Amended on 06.05.2013 Issue Date 28.06.2012 Valid Until 27.06.2014 Page 4 of 10 14. 15. 16. 17. 18. 19. Quantity Measured/ Instrument FEELER GAUGE ' BEVEL PROTRACTOR ' ANGLE PROTRACTOR/ COMBINATION SETl STEEL TAPE l L.C. 1mm STEEL RULE ' V BLOCK l Parallelism Squareness Range / Frequency Upto 1mm 0 to 360 Oto180 Upto 50 m Upto 1000mm Upto 300 mm Upto 300 mm 'Calibration Measurement Remarks f Capability () f 4.0 (im 3 minof arc 35 min 0.16x j L mm Vi L inmtr 80.0 urn 5.0 urn 11.0 urn 1 Using Digimatic Micrometer I Using Angle Block, Sine Bar, 1 Slip Gauges & Surface Plate 1 Using Angle Block, Sine Bar, 1 Slip Gauges & Surface Plat I Using Length Measuring 1 Machine J ji Using Length Measuring | Machine j Using Surface Plate, Plunger Dial & Analog Comparator 20. MASTER FOILS FOR COAT THICKNESS' 21. THREAD PLUG GAUGE' (Maj0 &Effective 0) 22. THREAD RING ' (Effective 0) Upto 1 mm Upto M l 00 M3 toM100 4.0 4.3 um 2.5 urn Using Digimatic Micrometer Using Floating Carriage, Measuring Pin & OD Master Using LMM & Master Ring 7. Laboratory MflBL Deportment offScience S Technology, India SCOPE OF ACCREDITATION QRICS Calibration Laboratories Pvt.Ltd.,' Paras' Complex, GP/67, Office No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune Accreditation Standard ISO/IEC 17025:2005 Discipline Mechanical Calibration Certificate Number C-0131 Last Amended on 06.05.2013 Issue Date 28.06.2012 I Valid Until 27.06.2014 | Page 5 of 10 Quantity Measured/ Instrument Range/ Frequency "Calibration Measurement Capability () Remarks 23. BORE GAUGE' (Transmission Mechanism check only) L.C. 0.001 mm L.C. 0.01 mm 24. ENGINEERS SQUARE/SQUARE BLOCK/ANGLE PLATE' Squareness Parallelism 25. SETTING ROD/RISER BLOCKl 26. SPIRIT LEVEL1 27. DIAL CALIBRATION TESTER' L.C. 0.001 mm 28. ELECTRONIC COMPARATOR PROBE' L.C. 0.0001 mm L.C. 0.01 mm Upto 1 mm stroke Upto 1mm stroke Upto 200 mm Upto 25 mm Upto 3 um Upto 30 um 4.6 urn 7.0 urn iO mm x 600 mm 10 mm x 600 mm Upto 150mm Upto 300 mm Upto 600 mm ll.Oum 5.4 (am 2.6 urn 3.0 um 4.0 um 9 um/m 2.6 um 1.4 um 1.2 m Using Electonic Dial Calibration Tester Using Plunger Dial, Analog | Comparator & Surface Plate | Using Plunger Dial, Slip I Gauges & Electronic Height| Gauge * Using Sinebar, Surface Plate & Slip Gauge Using Electronic Probe with DRO & Slip Gauges Using Slip Gauges 8. ^WSSWHP!^^ MflBL Laboratory Department offScience S Technology, India SCOPE OF ACCREDITATION QRICS Calibration Laboratories Pvt. Ltd.,' Paras' Complex, GP/67, Office No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune Accreditation Standard ISO/IEC 17025:2005 Discipline Mechanical Calibration Certificate Number C-0131 Last Amended on 06.05.2013 Issue Date 28.06.2012 Valid Until 27.06.2014 Page 6 of 10 j< 29. 30. 31. 32. 33. 34. 35. 36. Quantity Measured/ Instrument PISTOL CALIPER ' L.C. 0.1mm STANDARD STEEL WIRE GAUGE ' FLOW CUP1 (Jet Dia) CENTER DISTANCE ' SETTINGRING GAUGE ' PLAIN RING GAUGE' SINE BAR 1 Angle Parallelism Roller Distance COMPARATOR STAND l Flatness Squareness Range / Frequency "Calibration Measurement Remarks Capability () 0 to 50 mm 0 to 10 mm 0 4.0 mm Upto 300 mm Upto 100mm Upto 100mm 100 mm to 300 mm Upto 200 mm Upto 200 mm Upto 200 mm Upto 300 mm Upto 300 mm 60 um 13.0 um 4.0 urn 9.0 um 2.8 urn 5.40 um 5.50 um 11.0 Sec 3.5 um 5.4 um 4.6 um 6.7 um Using Slip Gauge Using Feeler Gauge & Slip j Gauge ] Using Hole Test & Digimatic Mic. | Using ElectronicHeight j Gauge 1 Using LMMUsing Electronic Height Gauge Using Slip Gauge & Surface Plate ; Using Dial Comparator i 37. TAPER THREAD PLUG1 Upto 100mm 5.0 Using FloatingCarriage I 9. ^*;iia9S3a^^ NflBL Laboratory Department of Science S Technology, India SCOPE OF ACCREDITATION QRICS Calibration Laboratories Pvt. Ltd.,' Paras' Complex, GP/67, Office No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune Accreditation Standard ISO/IEC 17025:2005 Discipline Mechanical Calibration Certificate Number C-0131 Last Amended on 06.05.2013 Issue Date 28.06.2012 Valid Until 27.06.2014 Page 7 of 10 38. 39. 40. 41. Quantity Measured/ Instrument TWO PINDIAL ' L.C. 0.01 mm L.C. 0.025mm DIAL SNAP GAUGE ' STRAIGHT EDGE ' Straightness Parallelism OD MASTER ' Diameter Concentricity Range / Frequency "Calibration Measurement Remarks Capability () 0 to 75 mm 0 to 75 mm Upto 100 mm Upto 1000 mm Upto 1000mm Upto 100mm Upto 100mm 8.0 urn 16.0 urn 2.5 urn 9.0 urn 5.5 urn 3.0 urn 3.5 urn Using Micrometer & Dial Calibration Tester Using Slip Gauges Using Surface Plate & Plunger Dial Using Analog Comparator i Slip Gauges 42. PLAIN TAPER PLUG GAUGE' 43. RADIUS GAUGE l 44. THREAD PITCH GAUGE' Angle Linear 45. PLAIN TAPER RING GAUGE' Angle Measurement upto 100mm Upto 25 mm 60 60 Angle Measurement 12minof Arc 7.9 urn 12minof Arc 8.5 urn 60" Using Profile Projector/ Electronic Height Gauge & Slip Gauges Using Profile Projector Using Profile Projector Using ElectronicHeight Gauge/ Gauge Blocks 10. ^^^ Laboratory NflBL Department offScience a Technology, India SCOPE OF ACCREDITATION QRICS Calibration Laboratories Pvt.Ltd.,' Paras' Complex, GP/67, Office No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune Accreditation Standard ISO/IEC 17025:2005 Discipline Mechanical Calibration Certificate Number C-0131 Last Amended on 06.05.2013 Issue Date 28.06.2012 Valid Until 27.06.2014 Page 8 of 10 Quantity Measured/ Instrument Range/ Frequency "Calibration Measurement Capability () Remarks 46. V GROOVE MICROMETER' L.C. 0.01 mm L.C. 0.001 mm 47. GRATICULE' L.C. 0.05 mm Linear 48. SURFACE PLATE 2 49. FLOATING CARRIAGE l L.C. 0.0001 mm 50. THREAD MEASURING WIRES' 51. THREAD MEASURING PRISMS ' 52. SLIP GAUGE SET' Upto 100mm Upto 100mm 0 to 25mm 2500 mm x 2500 mm Oto 100mm 0.17 mm to 6.35mm A/B/C/D Upto 20 mm 20 mm to 50 mm 50 mm to 100 mm 1.2x 7.0 urn 2.17 urn 30.0 + 100 2.7 urn 1.4 urn 1.4 um um 0.14 urn 0.23 urn 0.32 xm Using OD Master Using Profile Projector Using Spirit Level Using Slip Gauges, OD Master &Mandril Using Electronic Probe As per IS 6311 | $ I Using Electronic Probe 1 As per IS 6150 J Using Slip Gauge Calibrator } 11. Laboratory NflBL Department offScience fi Technology, India SCOPE OF ACCREDITATION QRICS Calibration Laboratories Pvt. Ltd.,' Paras' Complex, GP/67, Office No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune Accreditation Standard ISO/IEC 17025:2005 Discipline Mechanical Calibration Certificate Number C-0131 Last Amended on 06.05.2013 Issue Date 28.06.2012 Valid Until 27.06.2014 Page 9 of 10 Quantity Measured/ Instrument Range/ Frequency "Calibration Measurement Capability () Remarks S3. PROFILE PROJECTOR' X-Y Axis L.C. 0.001 mm L.C. 0.005 mm Angular Scale Magnification 54. TRAVERSE OF CUPPING MACHINE 2 L.C. 0.05 mm 55. PRESSURE GAUGE CALIBRATION ' Upto 300 mm Screen & Traverse 100 mm 56. PRESSURE / VACUUM GAUGE CALIBRATION 3 57. PRESSURE GAUGE CALIBRATION 2 0 to 20 mm 1 kg/cm2to 65 kg/cm2 70 kg/cm2to 700 kg/cm2 0 to 20 kg/cm2 0 to 700 kg/cm2 -0.68 kg/cm2to 0 kg/cm2 0 to 20 kg/cm2 0 to 700 kg/cm2 2.5 urn 6.5 jam 4 minof arc 0.07% 0 to 0.06 mm 4.7%ofrdg 0.53% of rdg 3.35% of rdg 11.61% of rdg 6.67% of rdg 8.23% of rdg 11.61% of rdg Using Slip Gauges, Steel Ball, Digital Caliper & Angle Blocks Using Digital Depth Vernier Using Dead Weight Tester Using Digital Pressure GaugeS and Pumping Set | by Comparison Method Using Digital Pressure Gauge| and Pumping Set Comparison Method Using Digital Pressure Gauge 1 and Pumping Set J Comparison Method | 12. Laboratory NflBL Department offScience a Technology, Indiq SCOPE OF ACCREDITATION QRICS Calibration Laboratories Pvt. Ltd.,' Paras' Complex, GP/67, Office No. 7, 8 & 9, Basement, Thermax Chowk, MIDC, Chinchwad, Pune Accreditation Standard ISO/IEC 17025:2005 Discipline Mechanical Calibration Certificate Number C-0131 Last Amended on 06.05.2013 Issue Date 28.06.2012 Valid Until 27.06.2014 Page 10 of 10 Quantity Measured/ Instrument Range/ Frequency "Calibration Measurement Capability () Remarks 58. HANDTORQUE TOOLS l All Classes Type I & II 0 to 5Nm 0 to 20Nm Oto 100 Nm 0 to 500 Nm Oto lOOONm 0.98% of rdg 0.98% of rdg 0.58% of rdg 0.62% of rdg 0.85% of rdg Using DigitalTorqueWrench Calibration System as per IS/ISO6789 * Measurement Capability is expressedas an uncertainty () at a confidence probability of 95% 1 Only in Permanent Laboratory 2 Only for Site Calibration 3 The laboratory is also capable for site calibration however; the uncertainty at site depends on the prevailingactual environmental conditionsand masterequipment used.