STANDARD DRAWINGS
REVIEWED AND UPDATED 2007 STANDARD DRAWINGS
REVIEWED AND UPDATED 2011 STANDARD DRAWINDS INCLUDING GAA.
V.C.D. 04/09
M.H. 06/11
PROJECT
DRAWING No.
OFSHEET
REVDETAILS
ISSUE APP'D DATE AMENDMENT
DESIGN
DRAWN
CHECKED
A
B
C
D
ENGINEERING SERVICES DEPT
PAPER
FILE NAME
A4
C
1 1
STANDARD DRAWINGS - MSC 001B.SELL
B.SELL
M.HUTCHINSON
DATEJUN 11
E
REVIEWED AND UPDATED 2000 STANDARD DRAWINGS06/07J.V.
GENERAL NOTES
STANDARD DRAWINGS INDEX
N.T.S.
150
MIN
150
MIN
300
R25
110 190 300
150
MIN
40
125
R15
R75
R225
110 190 300
150
MIN
125
9
SM1
150
MIN
125
25R
300
225R
15R110 190
300
110 40
200
150
MIN
150
R25
B1
LINE/LIP OF KERB
LINE/LIP OF KERB
450
B3
110 40300 LIP OF KERB
LINE OF KERB
150
MIN
300
R25
450
B2
40
110 40300 LIP OF KERB
LINE OF KERB
8
600
SM2
R225
R75
LINE OF KERB
15R
600
LIP OF KERB
LINE OF KERB
LIP OF KERB
EDGE STRIP
M1
150
MIN10R
300
15R
LINE/LIP OF KERB
50
M4
150
MIN
10R
300
15R
LINE/LIP OF KERB
40100
150
MIN
40
300
150
MIN9
600
M2
LIP OF KERB
LINE OF KERB
15R
600
LIP OF KERB
LINE OF KERB
50
300
15R
50
300
SHARP TRANSITION
300
SHARP TRANSITION
150
MIN
40
300
150
MIN9
600
M5
LIP OF KERB
LINE OF KERB
15R
600
LIP OF KERB
LINE OF KERB
100
30010 x 10 CHAMFER
300
40
10R15R
100
30010 x 10 CHAMFER
10R
NOTES:1. CONCRETE SHALL BE NORMAL CLASS N25 STANDARD STRENGTH
GRADE COMPLYING WITH THE REQUIREMENTS OF AS. 1379. REFER TOVICROADS STANDARD SPECIFICATION 703 FOR REQUIREMENTS OFCONCRETE TO BE USED IN EXTRUSION MACHINES.
2. REFER TO AUSTROADS GUIDE TO ROAD DESIGN PART 3: GEOMETRICDESIGN FOR THE RECOMMENDED USE OF KERBS AND CHANNELS.
3. MOUNTABLE KERBS M4, M5 AND M6 ARE DESIGNED TO DISCOURAGEMOST TRAFFIC FROM MOUNTING A TRAFFIC ISLAND OR MEDIANEXCEPT FOR LONG OR OVER DIMENSIONAL VEHICLES, EG. THE KERBON THE OUTER EDGE OF THE MOUNTABLE APRON OF AROUNDABOUT'S CENTRAL ISLAND. THESE KERBS SHALL NOT BE USEDWHERE THERE IS A LIKELIHOOD THAT CYCLISTS, PEDESTRIANS ORPRAMS WILL CROSS THE KERB.
BARRIER KERBSNOT TO SCALE
MOUNTABLE KERBS(REFER TO NOTE 2)
NOT TO SCALE
SEMI-MOUNTABLE KERBSNOT TO SCALE
200
OPEN INVERT CHANNELSM3
M6
M3
50 50
600
250
75
R25
75
300 300
LIP OF KERB
LINE OF KERB
LINE OF KERB
008
STANDARD DRAWINGS FORSUBDIVISIONS IN GROWTH AREASKERB PROFILESB, M, & SM SERIES
1APR 2011
Revision
FigureDate
X:\Drawings & Graphics\Library\Engineering Design and Construction Manual\31-24931-FIG008 REV_1.dwgCad File No:12 April 2011 - 3:14 PMPlot Date: Gary MagnoPlotted by:
DateApprovedCheckedDrawnRevisionNo Note: * indicates signatures on original issue of drawing or last revision of drawing
PROJECT
Ref No.
OFSHEETREV
DETAILS
ISSUE APPVD DATE AMENDMENT
DESIGN
DRAWN
DATE
CHECKED
SCALE
A
B
C
D
M.H
M.H
J.V
06/07
1:2
This symbol shall be marked onthe face of the kerb immediatelyabove the position where atelecommunications serviceconduit is placed.
This symbol shall be marked onthe face of the kerb immediatelyabove the position where anelectrical service conduit isplaced.
This symbol shall be marked onthe footpath immediatelyopposite the position where ahouse drain is connected to amain drain.
This symbol shall be marked onthe face of the kerb immediatelyabove the position where a longwater service conduit is placedacross the roadway.
This symbol shall be marked onthe face of the kerb immediatelyabove the position where a gasservice conduit is placed.
This symbol shall be markedon the face of the kerb in linewith the position where ashort water service is placed.
ENGINEERING SERVICES DEPT
Standard Drawings - MSC 104
Kerb Markings
This symbol shall be marked onthe face of the kerb immediatelyabove the position where arecycled water service conduitis placed.
J.V 06/07
Reviewed and updated 2000 standard drawings
PIT/ACCESS HOLE AT EDGE (PLAN)
SCALE NTS
PIT/ACCESS HOLE NOT AT EDGE (PLAN)
SCALE NTS
W.P.JW.P.J
W.P.J
W.P.J
W.P.J W.P.J W.P.J
E.J
E.J
E.J
E.J
E.J
E.J
NOTES:1. FOUR TIE BARS TO BE INSTALLED AT 300 MAXIMUM CENTRES COMMENCING
150 FROM EDGE AT EACH E.J. OR C.J. EXPANSION JOINTS AT MAXIMUM 18mCENTRES.
2. WEAKENED PLANE JOINTS SHALL BE LOCATED AT 1500 CENTRESAND MAY BE MADE WITH A 'T' IRON (OR CONCRETE SAW WITHIN24-36Hrs OF POUR).
3. THE FINISHED SURFACE SHALL HAVE A LIGHT BROOM FINISH WITH ALLJOINTS AND EDGES HIGHLIGHTED.
4. CONCRETE USED FOR RESIDENTIAL FOOTPATH SHALL BE25MPa AT 28 DAYS. (32MPa FOR COLOURED CONCRETE).
5. CONCRETE USED FOR INDUSTRIAL FOOTPATH SHALL BE32MPa AT 28 DAYS. (32MPa FOR COLOURED CONCRETE).
6. FORMWORK TIMBER TO BE MIN. 90mm DEEP.7. ALL DIMENSIONS IN mm.8. SHARED PATHS TO BE 2.5m IN WIDTH.9. WHERE APPROVED RECYCLED MATERIAL CAN BE USED
W.P.J W.P.J W.P.J
REFER FIGURE 006 FOR JOINT DETAILSW.P.J = WEAKENED PLANE JOINTE.J = EXPANSION JOINT
007
STANDARD DRAWINGS FORSUBDIVISION IN GROWTH AREASCONCRETE JOINT DETAILS
1APR 2011
Revision
FigureDate
X:\Drawings & Graphics\Library\Engineering Design and Construction Manual\31-24931-FIG007 REV_1.dwgCad File No:12 April 2011 - 3:14 PMPlot Date: Gary MagnoPlotted by:
DateApprovedCheckedDrawnRevisionNo Note: * indicates signatures on original issue of drawing or last revision of drawing
A A
P.J 10/09 ADDING WARNING AND DIRECTIONAL TACTILES & SPLAY DETAIL
PROJECT
DRAWING No.OF
SHEET
REVDETAILS
ISSUE APPVD DATE AMENDMENT
DESIGN
DRAWN
DATE
CHECKED
SCALE
A
B
C
D
REVIEWED AND UPDATED 2000 STANDARD DRAWINGSENGINEERING SERVICES DEPT
PAPER
FILE NAMEMSC 202.DWG
A4
#### B
M.H.
JUN 07J.V. 06/07
M.H.
J.V.
STANDARD DRAWINGS - MSC 202
PRAM CROSSING
N.T.S.
1 106/12 UPDATING WARNING AND DIRECTIONAL TACTILES & NOTESM.H
ADDED TABLE 1 & TABLE 2
REVIEWED AND UPDATED 2011 STANDARD DRAWINGS TO MATCH GAA
V.C.D. 03/09
M.H. 06/11
PROJECT
DRAWING No.
OFSHEET
REVDETAILS
ISSUE APP'D DATE AMENDMENT
DESIGN
DRAWN
CHECKED
A
B
C
D
ENGINEERING SERVICES DEPT
PAPER
FILE NAME
A4
D
1 1
STANDARD DRAWINGS - MSC 301
SINGLE RESIDENTIAL VEHICLE CROSSING
B.SELL
B.SELL
M.HUTCHINSON
DATEMAR 11
E
REVIEWED AND UPDATED 2000 STANDARD DRAWINGS06/07J.V.
GENERAL NOTES
N.T.S.REMOVED WINGS AND REPLACED WITH SPLAYSV.C.D 01/13
NOTES:1. PIT BASE TO BE HAUNCHED WHERE ØPIPE + 100 > MIN PIT SIZE.
2. PIPE CENTRELINE TO BE 12 ØPIPE + 150 BEHIND B.O.K.
3. PIT WALLS AND FLOOR:- 150 THICK FOR DEPTH TO 3600- 200 THICK FOR DEPTH > 3600
4. PITS > 900 DEPTH TO BE SUPPLIED WITH STEP IRONS.
5. SUBJECT TO COUNCIL APPROVAL PRECAST PITS MAY BE SUBSTITUTED.
6. PIT TO MATCH FINISHED SURFACE LEVELS.
7. FOR GRATED PITS, GALVANISED LID IN ACCORDANCE WITH AS3996.
8. PITS IN ROAD RESERVE SUBJECTED TO TRAFFIC LOADING TO HAVE CLASS D COVERS,AS PER AS3996. OTHERWISE LIDS TO BE:-LIGHT WEIGHT FIBREGLASS CLASS 'B' OR ABOVE-NOT GREATER THAN 25KG IN WEIGHT FOR 600x900 PIT.
-IMPRINTED WITH "AS 3996" CLASS 'B' AND WEIGHT IN KILOGRAMS, IN 25mm LETTERING.
TABLE 2: JUNCTION PIT IN ROAD RESERVE MINIMUM INTERNALPIT SIZE ACCORDING TO PIT DEPTH ( SEE NOTE 1)
TABLE 1: EASEMENT PIT - MINIMUM INTERNAL SIZE ACCORDINGTO PIT DEPTH (SEE NOTE 1)
PLAN (LID REMOVED)
NOT TO SCALE
B BSTEP IRONSSEE NOTE 4
ATTACH FRAME WITH 10Ø 75MMLONG DYNABOLT
LIGHT WEIGHT LOCKING FIBREGLASS LIDAND FRAME OR APPROVED EQUIVALENT
DEPT
H
SEENOTE 3
SEE
NOTE
3 PIT SIZE SEE TABLE 1
SEE
NOTE
3
AGRICULTURAL DRAIN INLET
BOTTOM TO BE SHAPED ON COMPLETIONOF PIT ("NO SLUMP" CONCRETE)
SECTION A-A
NOT TO SCALE
SECTION B-BNOT TO SCALE
AGRICULTURALDRAIN INLET
STEP IRONSSEE NOTE 4
BOTTOM OF PIT SHAPEDON COMPLETION
SEE
NOTE
3 PIT SIZE SEE TABLE 1
SEE
NOTE
3
A
A100 * 100 CONCRETE SURROUND TO LID FRAME
100 x 100 CONCRETE SURROUNDLID FRAME
ATTACH FRAME WITH 10Ø75mm LONG DYNABOLT A
A
*FIX BOLTS THIS SIDE TO ACHIEVE MIN EDGE DIST.
D/2
DEPTH PIT SIZE FRAME SIZE<1000 600 x 600 825 x 825>1000 600 x 900 800 x 1100
DEPTH PIT SIZE FRAME SIZEALL 600 x 900 800 x 1100
75mm LAYER OFCOMPACTED CLASS 2 FCR
75mm LAYER OF COMPACTEDCLASS 2 FCR
014
STANDARD DRAWINGS FORSUBDIVISIONS IN GROWTH AREASJUNCTION PIT
1APR 2011
Revision
FigureDate
X:\Drawings & Graphics\Library\Engineering Design and Construction Manual\31-24931-FIG014 REV_1.dwgCad File No:12 April 2011 - 3:36 PMPlot Date: Gary MagnoPlotted by:
DateApprovedCheckedDrawnRevisionNo Note: * indicates signatures on original issue of drawing or last revision of drawing
AS S
PECI
FIED
100
200
WIDTH 600
300
490
300
60
225 M
IN.
B2
"BIKE-SAFE" HOT DIP GALVANISEDOR CAST IRON CLASS D AS PERAS3996. GRATING & FRAME TOSUIT BARRIER KERB PROFILE
CAST IN-SITUOR PER-CASTUNIT TO SUIT
OR LO
CATE
GRA
TE P
ITAT
AN
ANGL
E TO
JUNC
TION
PIT
600150 150
PENETRATION FORSUBSURFACE DRAINS
PIPE CENTRED IN PIT
75mm LAYER OF COMPACTEDCLASS 3 FCR
SECTION A-A
NOT TO SCALE
150 300
E.J.
BACK
OF
KERB
LIP O
F KE
RB
E.J.
"BIKE SAFE" HOT DIP GALVANISEDOR CAST IRON CLASS D AS PERAS3996. GRATING & FRAME TO SUITBARRIER KERB PROFILE
A
PLAN
NOT TO SCALEFA
CE O
F KE
RB
(CAS
T IN
-SIT
U OR
PRE
-CAS
T UN
IT)
NOTES:1. INSIDE DIMENSIONS OF SIDE ENTRY PITS TO BE 900x600 FOR PIPES NOT EXCEEDING
450Ø. LARGER PIPES REQUIRE PIT HAUNCHING AS PER VICROADS SD1001 TO SD1023.2. REINFORCEMENT FOR THE PIT DIA < 450mm AND DEPTH > 1200mm. REFER VICROADS
DWG SD1011D. FOR HAUNCHED PITS REINFORCEMENTS ARE TO BE AS SHOWN INTHE VICROADS STD. DWG. 1121B.
3. PIPE CENTRELINE TO BE 450 MINIMUM OR 12 ØPIPE +150mm BEHIND BOK.
4. PIT WALLS AND FLOOR:- 150 THICK FOR DEPTH TO 3600.- 200 THICK FOR DEPTH > 3600.
5. PITS > 900 DEPTH TO BE SUPPLIED WITH STEP IRONS - REFER TO VICROADS SD1041.6. SUBJECT TO SUPERINTENDENT'S & COUNCIL APPROVAL PRECAST PITS MAY BE
SUBSTITUTED.
LENG
TH90
0
WIDTH600
A
E.A FRAME AND LIGHT WEIGHT LOCKINGFIBREGLASS LID OR APPROVED EQUIVALENT
ATTACH FRAME WITH 10Ø 100mm LONGDYNABOLT THROUGH 25 x 25 x 50LONG RHS SPACER
E.A. FRAME AND LIGHT WEIGHT LOCKINGFIBREGLASS LID OR APPROVEDEQUIVALENT
100 x 100 CONCRETE SURROUNDTO LID FRAME GROUT BETWEENFRAME AND PIT STRUCTURE
SEE
NOTE
4
600 OR DIA+150 MIN(WHICHEVER IS >)
SEE NOTE 1
SEE
NOTE
4
SEE
NOTE
4
BOTTOM TO BE SHAPED ONCOMPLETION OF PIT ("NOSLUMP" CONCRETE)
D/2
1000
TAP
ER7. TOP OF PIT TO MATCH FINISHED SURFACE LEVELS.8. STEP IRONS TO BE PROVIDED IN ALL PITS OVER 900mm DEEP.9. CONCRETE STRENGTH 25MPa AT 28 DAYS.10. ALL PIT COVERS AND GRATES IN ACCORDANCE WITH AS3996.
FIBRE GLASS LIDS:-TO BE CLASS 'B' OR ABOVE-NOT GREATER THAN 25KG IN WEIGHT FOR 600x900 PIT.-IMPRINTED WITH "AS 3996" CLASS 'B' AND WEIGHT IN KILOGRAMS, IN 25mmLETTERING
11. NOT APPLICABLE TO MELBOURNE WATER CORPORATION DRAINAGE ASSETS. FORMWC WORKS REFER TO MWC LAND DEVELOPMENT MANUAL.
012
STANDARD DRAWINGS FORSUBDIVISIONS IN GROWTH AREASSIDE ENTRY PIT GRATEDB2 KERB AND CHANNEL
1APR 2011
Revision
FigureDate
X:\Drawings & Graphics\Library\Engineering Design and Construction Manual\31-24931-FIG012 REV_1.dwgCad File No:12 April 2011 - 3:35 PMPlot Date: Gary MagnoPlotted by:
DateApprovedCheckedDrawnRevisionNo Note: * indicates signatures on original issue of drawing or last revision of drawing
150
AS S
PECI
FIED
100
200
WIDTH
300
490
300
60 225 M
IN.
SM2
"BIKE-SAFE" HOT DIP GALVANISED ORCAST IRON CLASS D AS PER AS 3996.GRATING & FRAME TO SUIT SM2PROFILE
CAST IN-SITU OR PER-CASTUNIT TO SUIT
OR LO
CATE
GRA
TE P
ITAT
AN
ANGL
E TO
JUNC
TION
PIT
150 150
PENETRATION FORSUBSURFACE DRAINS
150
E.J.
BACK
OF
KERB
E.J.
"BIKE SAFE" HOT DIP GALVANISED OR CASTIRON CLASS D AS PER AS 3996. GRATING &
FRAME TO SUIT SM2 KERB PROFILE
A
PLAN
NOT TO SCALEFA
CE O
F KE
RB
(CAS
T IN
-SIT
U OR
PRE
-CAS
T UN
IT)
LENG
TH90
0
WIDTH600
A
E.A FRAME AND LIGHT WEIGHT LOCKINGFIBREGLASS LID OR APPROVEDEQUIVALENT
ATTACH FRAME WITH 10Ø 100mm LONGDYNABOLT THROUGH 25 x 25 x 50LONG RHS SPACER
E.A. FRAME AND LIGHT WEIGHT LOCKINGFIBREGLASS LID OR APPROVEDEQUIVALENT
100 x 100 CONCRETE SURROUNDTO LID FRAME GROUT BETWEENFRAME AND PIT STRUCTURE
600
400
PIPE CENTRED IN PIT
75mm LAYER OF COMPACTEDCLASS 3 FCR
SECTION A-A
NOT TO SCALE
SEE
NOTE
4
600 OR DIA+150 MIN(WHICHEVER IS >)
SEE NOTE 1
SEE
NOTE
4
SEE
NOTE
4
BOTTOM TO BE SHAPED ONCOMPLETION OF PIT ("NOSLUMP" CONCRETE)
D/2LIP
OF
KERB
NOTES:1. INSIDE DIMENSIONS OF SIDE ENTRY PITS TO BE 900 x 600 FOR PIPES NOT EXCEEDING
450Ø. LARGER PIPES REQUIRE PIT HAUNCHING AS PER VICROADS SD1001 TO SD1023.2. REINFORCEMENT FOR THE PIT DIA < 450mm AND DEPTH > 1200mm. REFER VICROADS
DWG SD1011D. FOR HAUNCHED PITS REINFORCEMENTS ARE TO BE AS SHOWN IN THEVICROADS STD. DWG. 1121B.
3. PIPE CENTRELINE TO BE 450 MINIMUM OR 12 ØPIPE +150mm BEHIND BOK.
4. PIT WALLS AND FLOOR:- 150 THICK FOR DEPTH TO 3600.- 200 THICK FOR DEPTH > 3600.
5. PITS > 900 DEPTH TO BE SUPPLIED WITH STEP IRONS - REFER TO VICROADS SD1041.6. SUBJECT TO SUPERINTENDENT'S & COUNCIL APPROVAL PRECAST PITS MAY BE
SUBSTITUTED.7. TOP OF PIT TO MATCH FINISHED SURFACE LEVELS.8. STEP IRONS TO BE PROVIDED IN ALL PITS OVER 900mm DEEP.9. CONCRETE STRENGTH 25MPa AT 28 DAYS.10. ALL PIT COVERS AND GRATES IN ACCORDANCE WITH AS3996.
FIBRE GLASS LIDS:-TO BE CLASS 'B' OR ABOVE-NOT GREATER THAN 25KG IN WEIGHT FOR 600x900 PIT.-IMPRINTED WITH "AS 3996" CLASS 'B' AND WEIGHT IN KILOGRAMS, IN 25mm LETTERING
11. NOT APPLICABLE TO MELBOURNE WATER CORPORATION DRAINAGE ASSETS. FORMWC WORKS REFER TO MWC LAND DEVELOPMENT MANUAL.
013
STANDARD DRAWINGS FORSUBDIVISIONS IN GROWTH AREASSIDE ENTRY PIT GRATEDSM2 KERB AND CHANNEL
1APR 2011
Revision
FigureDate
X:\Drawings & Graphics\Library\Engineering Design and Construction Manual\31-24931-FIG013 REV_1.dwgCad File No:12 April 2011 - 3:36 PMPlot Date: Gary MagnoPlotted by:
DateApprovedCheckedDrawnRevisionNo Note: * indicates signatures on original issue of drawing or last revision of drawing
A
A
1. FOR USE ON PIPES AT GRADES OF 1 IN 10 OR STEEPER.
2. TO BE CONSTRUCTED AT MID POINT OF EVERY FOURTH 2.44mLENGTH PIPE. SPACING NO GREATER THAN 10m.
3. CONCRETE STRENGTH TO BE 25 MPa.
NOTES:ELEVATIONNOT TO SCALE
SECTION A-A
NOT TO SCALE
WIDTH OF TRENCH(O.D + 300)
150 15015
015
0
75m
m
PIPE BEDDING
225
I.D.
150
300mm
COLLAR TO BE LOCATEDUPSTREAM OF ANCHOR
RUBBER RING JOINT
O.DOUTSIDE DIA.
015
STANDARD DRAWINGS FORSUBDIVISIONS IN GROWTH AREASDRAINAGE PIPELINESANCHOR BLOCK DETAIL
1APR 2011
Revision
FigureDate
X:\Drawings & Graphics\Library\Engineering Design and Construction Manual\31-24931-FIG015 REV_1.dwgCad File No:12 April 2011 - 3:16 PMPlot Date: Gary MagnoPlotted by:
DateApprovedCheckedDrawnRevisionNo Note: * indicates signatures on original issue of drawing or last revision of drawing
FALL OF LOT
PROPERTY INLET
TITLE BOUNDARY
EASEMENT DRAIN
TITT
LE B
OUND
ARY
PVC SOCKET ADAPTOR,CONCONNECT, OR APPROVED
EQUIVALENT, THEN RENDER JOINT
NOTES:1. ALL PIPES AND FITTINGS TO BE OF 100mm PVC SEWER CLASS HEAVY, REFER AS 1260.
2. FOR SHALLOW DRAINS, COUNCILS ENGINEER MAY GIVE APPROVAL TO CONNECT THEPROPERTY DRAIN INTO THE SIDE OF THE DRAIN.
3. DEPTH 'D' TO BE MINIMUM 600mm OR GREATER AS DIRECTED BY COUNCIL ENGINEER.
4. BACKFILLING / HAUNCHING TO BE CLASS 3 FCR.
5. ALL DIMENSIONS IN MILLIMETRES OR AS NOTED OTHERWISE.
6. NOT APPLICABLE TO MELBOURNE WATER CORPORATION DRAINAGE ASSETS. FOR MWCWORKS REFER TO MWC LAND DEVELOPMENT MANUAL.
TYPICAL LOCATIONEASEMENT DRAIN
NOT TO SCALE
600
MIN
1000
PUSH ON CAP
300
D
600 1000 (MIN)
OR OFFSET AS SPECIFIED
INSPECTION OPENING TO BE SEALEDWITH THREADED CAP
MIN PIPEFALL TO BE
1 IN 30
INLET FOR HOUSE CONNECTIONSEALED WITH THREADED CAP
90° JUNCTION
STREET OR EASEMENT DRAIN
DVA
RIAB
LE D
EPTH
ELEVATIONNOT TO SCALE
FALL OF LOT
PROPERTY INLET
TITLE BOUNDARY
ROAD RESERVE
TYPICAL LOCATIONSTREET DRAIN
NOT TO SCALE
5500
STREET DRAIN
600
MIN
016
STANDARD DRAWINGS FORSUBDIVISIONS IN GROWTH AREASPROPERTY INLETTYPE A
1APR 2011
Revision
FigureDate
X:\Drawings & Graphics\Library\Engineering Design and Construction Manual\31-24931-FIG016 REV_1.dwgCad File No:12 April 2011 - 3:16 PMPlot Date: Gary MagnoPlotted by:
DateApprovedCheckedDrawnRevisionNo Note: * indicates signatures on original issue of drawing or last revision of drawing
N.S.LFALL OF LOT
PROPERTY INLET
TITLE BOUNDARY
EASEMENT DRAIN
TYPICAL LOCATIONNOT TO SCALE
1000
NOTES:1. ALL PIPES AND FITTINGS TO BE OF 100mm PVC SEWER CLASS HEAVY, REFER AS 1260.
2. FOR SHALLOW DRAINS, COUNCILS ENGINEER MAY GIVE APPROVAL TO CONNECT THEPROPERTY DRAIN INTO THE SIDE OF THE DRAIN.
3. DEPTH 'D' TO BE MINIMUM 600mm OR GREATER AS DIRECTED BY COUNCIL ENGINEER.
4. BACKFILLING / HAUNCHING TO BE CLASS 3 FCR.
5. ALL DIMENSIONS IN MILLIMETRES OR AS NOTED OTHERWISE.
PUSH ONCAP
300
INLET FOR HOUSE CONNECTIONSEALED WITH THREADED CAP
90° 'T' JUNCTION
EASEMENT DRAIN
DVA
RIAB
LE D
EPTH
ELEVATIONNOT TO SCALE
PVC SOCKET ADAPTOR,CONCONNECT, OR EQUIVALENT,THEN RENDER JOINT
017
STANDARD DRAWINGS FORSUBDIVISIONS IN GROWTH AREASPROPERTY INLETTYPE B
1APR 2011
Revision
FigureDate
X:\Drawings & Graphics\Library\Engineering Design and Construction Manual\31-24931-FIG017 REV_1.dwgCad File No:12 April 2011 - 3:16 PMPlot Date: Gary MagnoPlotted by:
DateApprovedCheckedDrawnRevisionNo Note: * indicates signatures on original issue of drawing or last revision of drawing
TITL
E BO
UNDA
RY
TITL
E BO
UNDA
RY
FAUCET TO BEINSTALLED IN WALL
DURING CONSTRUCTION
MIN FALL1 IN 30
90° 'T' JUNCTION
INLET FOR HOUSECONNECTION SEALEDWITH THREADED CAP
90° 'T'JUNCTION
MIN FALL1 IN 30
FAUCET TO BEINSTALLED IN WALLDURING CONSTRUCTION
FOOTPATH TO BE MARKED WITH75MMØ CIRCLE AT PROPERTY
INLET CONNECTION.
NOTES:1. ALL PIPES AND FITTINGS TO BE OF 100mm PVC SEWER CLASS HEAVY, REFER AS 1260.
2. DEPTH 'D' TO BE MINIMUM 600mm OR GREATER AS DIRECTED BY COUNCIL ENGINEER.
3. BEDDING TO BE COMPACTED DEPTH OF 50MM CLASS 3 CRUSHED ROCK.
4. BACKFILLING AND HAUNCHING TO BE CLASS 3 FCR.
5. TRENCH UNDER FOOTPATH TO BE BACKFILLED WITH COMPACTED 20MM CLASS 3
CRUSHED ROCK TO UNDERSIDE OF FOOTPATH.
6. IF THE HOLE FOR THE PIPE IS NOT AVAILABLE, A HOLE IS TO BE COLD DRILLED.
7. ALL DIMENSIONS IN MILLIMETRES OR AS NOTED OTHERWISE.
1000OR OFFSET AS SPECIFIED
PUSH ON CAP
600
300
D
300
D
PUSH ON CAP6001000 (MIN)
OR OFFSET AS SPECIFIED
EASEMENT DRAINAGE ELEVATIONNOT TO SCALE
STREET DRAINAGE ELEVATIONNOT TO SCALE
STREET DRAINAGEINLET FOR HOUSECONNECTION SEALEDWITH THREADED CAP
EASEMENTDRAINAGE
018
STANDARD DRAWINGS FORSUBDIVISIONS IN GROWTH AREASPROPERTY INLETTYPE D
1APR 2011
Revision
FigureDate
X:\Drawings & Graphics\Library\Engineering Design and Construction Manual\31-24931-FIG018 REV_1.dwgCad File No:12 April 2011 - 3:16 PMPlot Date: Gary MagnoPlotted by:
DateApprovedCheckedDrawnRevisionNo Note: * indicates signatures on original issue of drawing or last revision of drawing
Notes
1. This is Councils minimum standard for backfill, refer to service authority standards wheninstalling services.
2. Any works within the road reserve must obtain consent as per the Road Management Act.
3. All work must be guaranteed for a twelve month maintenance period in accordance withthe Road Management Act or longer by agreement with Shire of Melton
4. Backfill under road pavements may be either of the three following options20mm Class 3 crushed rock as per note 11
5. Pipe trenches beneath crossovers or adjacent to kerbing up to the level that is affected bya 45 degrees angle of repose must be filled as per Backfill in road pavements.
6. Pipe offset in easements to be a minimum of 1000mm from title boundary.
7. Drainage pipe offset behind kerb to be minimum (0.5 x diameter) + 600mm.
8. All excavations under vehicle crossings and footpaths are to be backfilled with a minimum20mm Class 4 FCR with a 50mm layer of 20mm Class 3 FCR placed immediately belowthe vehicle crossing or footpath.
9. All trench construction shall be in accordance with the current O.H & safety regulations.
10. Existing concrete and asphalt surface shall be saw cut to provide neat and clean edge, forexcavation. Full bays of damaged concrete to be replaced. Footpath shall be joined toexisting in accordance with Expansion Joint on GAA 006. Kerb and Channel to be joinedto existing with 3 x 400mm long N12 bars at each end.
11. Class 3 material to be mechanically compacted at 97% modified compaction in layers notexceeding 200mm loose thickness.
12. Earth backfill to be mechanically compacted at 95% standard compaction in layers notexceeding 200mm loose thickness.
13. All pipe jointing and laying shall be constructed in accordance with the manufacturer'sspecifications. Should there be any disagreement between the Melton Shire CouncilStandard Drawings and the manufacturer's specifications, please refer to Council Engineer.
DELETED ROAD VERGE DRAWING AND MODIFIED NOTES
DELETED KERB AND CROSSFALL AND MODIFIED NOTES
P.J. 04/08
M.H 06/11
PROJECT
DRAWING No.
OFSHEET
REVDETAILS
ISSUE APP'D DATE AMENDMENT
DESIGN
DRAWN
CHECKED
A
B
C
D
ENGINEERING SERVICES DEPT
PAPER
FILE NAME
A4
C
1 1
STANDARD DRAWINGS - MSC 506B.SELL
B.SELL
M.HUTCHINSON
DATEJUL 11
E
REVIEWED AND UPDATED 2000 STANDARD DRAWINGS06/07J.V.
GENERAL NOTES
PIPE BEDDING & RE-INSTATEMENTS
N.T.S.
PLATE ROCK LENGTH TO DEPTH RATIO SHALL BEGREATER THAN 2.5:1
MORTAR PAD BETWEEN PIPE AND ROCKSABUTTING PIPE (NO POINT LOADS)
OUTLINE OF CUTOFFWALL
BANK ROCKWORK TO FINISH FLUSHWITH SURROUNDING GROUND
LEGEND:
TOE/EDGE ROCKS
LINING ROCK
FILTER/EMBEDMENT LAYER
SECTION B-BNOT TO SCALE
ROCKWORK TO FINISH FLUSH WITHSURROUNDING GROUND
PLATE ROCK
D
MORTAR PAD UNDER PLATE ROCK
MORTAR TO SEAL OFF UNDER PIPE500MIN15
0
150
REFER TO NOTE 4
500 MIN.(REFER TO NOTE 4)
SL81 CENTRALLY PLACED
NOTES:1. REFER TO SEC. 5.14 OF MELBOURNE WATER LAND DEVELOPMENT
MANUAL FOR GENERAL NOTES ON ROCKWORK.
2. REFER TO SECTION 5.4.3 OF MELBOURNE WATER LAND DEVELOPMENTMANUAL FOR MORE INFORMATION ON DRAINAGE CONNECTIONS.
3. CUT OFF WALL TO EXTEND VERTICALLY TO SOLID GROUND (MIN. 500mmBELOW PIPE) AND HORIZONTALLY TO FULL PIPE BEDDING CONDITIONS.
4. OUTLET PIPE SHALL BE INTERGRATED INTO SURROUNDING LANDSCAPETO MAXIMISE AESTHETICS AND MINIMISE IMPACTS. THIS MAY INVOLVESUITABLE PLANTING WORKS.
5. A 'PERMIT TO WORK' MUST BE OBTAINED PRIOR TO THECOMMENCEMENT OF WORKS IF CONNECTIONG TO AN EXISTINGMELBOURNE WATER WATERWAY.CUT OFF WALL DETAIL
NOT TO SCALE
019
STANDARD DRAWINGS FORSUBDIVISIONS IN GROWTH AREASOUTFALL STRUCTURE
1APR 2011
Revision
FigureDate
X:\Drawings & Graphics\Library\Engineering Design and Construction Manual\31-24931-FIG019 REV_1.dwgCad File No:12 April 2011 - 3:16 PMPlot Date: Gary MagnoPlotted by:
DateApprovedCheckedDrawnRevisionNo Note: * indicates signatures on original issue of drawing or last revision of drawing
150
300
450
EXISTING SUBGRADE
KERB PROFILE ASSPECIFIED
PAVEMENT COMPOSITION AS PERCOUNCIL APPROVED DESIGN
50mm TOPSOIL DRESSING ASSPECIFIED
TYPE B FILLAS SPECIFIED
100mm CLASS 400 PERFORATED PVCAGRICULTURAL PIPE IN 20mm SIZESCREENINGS, CLEAN SCORIA ORAPPROVED EQUIVALENT.
300
300
MIN.
25mm BEDDING
SUBSURFACE DRAINNOT TO SCALE
450
600
1000
EXISTING SUBGRADE
KERB PROFILE ASSPECIFIED
PAVEMENT COMPOSITION AS PERCOUNCIL APPROVED DESIGN
50mm TOPSOIL DRESSINGAS SPECIFIED
TYPE B FILL ASSPECIFIED
100mm CLASS 400 PERFORATEDPVC AGRICULTURAL PIPE IN 20mmSIZE SCREENINGS, CLEAN SCORIAOR APPROVED EQUIVALENT.
300
SUBSURFACE DRAIN IN EXPANSIVE SOILSNOT TO SCALE
APPROVED IMPERVIOUS LOWER SUBBASE
125
NOTES:1. AGRICULTURAL DRAIN TO BE LOCATED
WITHIN THE APPROVED IMPERVIOUSLAYER AS SHOWN
020
STANDARD DRAWINGS FORSUBDIVISIONS IN GROWTH AREASSUBSURFACE DRAINBACK OF KERB
1APR 2011
Revision
FigureDate
X:\Drawings & Graphics\Library\Engineering Design and Construction Manual\31-24931-FIG020 REV_1.dwgCad File No:12 April 2011 - 3:16 PMPlot Date: Gary MagnoPlotted by:
DateApprovedCheckedDrawnRevisionNo Note: * indicates signatures on original issue of drawing or last revision of drawing
PROJECT
DRAWING No.
OFSHEET
REVDETAILS
ISSUE APP'D DATE AMENDMENT
DESIGN
DRAWN
CHECKED
A
B
C
D
ENGINEERING SERVICES DEPT
PAPER
FILE NAME
A4
A
1 1
STANDARD DRAWINGS - MSC 604B.SELL
B.SELL
M.HUTCHINSON
DATEJUN 11
E
REVIEWED AND UPDATED ROAD CROSS SECTIONS 201106/11M.H.
GENERAL NOTES
ROAD CLASSIFICATION - CONNECTORSTREET RESIDENTIAL
N.T.S.
PROJECT
DRAWING No.
OFSHEET
REVDETAILS
ISSUE APP'D DATE AMENDMENT
DESIGN
DRAWN
CHECKED
A
B
C
D
ENGINEERING SERVICES DEPT
PAPER
FILE NAME
A4
A
1 1
STANDARD DRAWINGS - MSC 606B.SELL
B.SELL
M.HUTCHINSON
DATEJUN 11
E
REVIEWED AND UPDATED ROAD CROSS SECTIONS 201106/11M.H.
GENERAL NOTES
ROAD CLASSIFICATION ACCESS STREET 1
N.T.S.
PROJECT
DRAWING No.
OFSHEET
REVDETAILS
ISSUE APP'D DATE AMENDMENT
DESIGN
DRAWN
CHECKED
A
B
C
D
ENGINEERING SERVICES DEPT
PAPER
FILE NAME
A4
A
1 1
STANDARD DRAWINGS - MSC 607B.SELL
B.SELL
M.HUTCHINSON
DATEJUN 11
E
REVIEWED AND UPDATED ROAD CROSS SECTIONS 201106/11M.H.
GENERAL NOTES
ROAD CLASSIFICATION - ACCESS STREET 2
N.T.S.
0.50 3.00 3.00 0.50
7.00m (MIN).
ES OPEN INVERTCHANNEL
ACCESS LANENOT TO SCALE
PRO
PERT
Y BO
UNDA
RY
PRO
PERT
Y BO
UNDA
RY
0.20
ES
0.20
1 in 40 1 in 40
0.50 3.00 3.00 0.50
7.00m (MIN).
ES OPEN INVERTCHANNEL
ACCESS LANENOT TO SCALE
PRO
PERT
Y BO
UNDA
RY
PRO
PERT
Y BO
UNDA
RY
0.20
ES
0.20
1 in 40 1 in 40
SUBSOIL DRAINDEPTH 300mmBELOW SUBBASE
001
STANDARD DRAWINGS FORSUBDIVISIONS IN GROWTH AREASACCESS LANECROSS SECTION
1APR 2011
Revision
FigureDate
X:\Drawings & Graphics\Library\Engineering Design and Construction Manual\31-24931-FIG001 REV_1.dwgCad File No:12 April 2011 - 3:13 PMPlot Date: Gary MagnoPlotted by:
DateApprovedCheckedDrawnRevisionNo Note: * indicates signatures on original issue of drawing or last revision of drawing
PRO
PERT
Y
B
OUN
DARY
SM2/B2 SM2/B2
5.500 (MIN)
2.750 (MIN) 2.750 (MIN)
16.000 (MIN)
VARIES4.200 (MIN)
1.500FOOTPATH
0.050
1.500FOOTPATH
0.050
VARIES4.200 (MIN)
1.500FOOTPATH 0.050
VARIES4.200 (MIN)
1 HARDSTAND PER LOT 2.300
SM2
ACCESS PLACE HARDSTANDNOT TO SCALE
PRO
PERT
Y
BO
UNDA
RY
NOTES:1. DIMENSIONS FROM INVERT OF KERB ASSUME B2 KERB2. MINIMUM DIMENSIONS ASSUME SM2 KERB
ACCESS PLACENOT TO SCALE
PRO
PERT
Y
B
OUN
DARY
FACE
FACE
FOOTPATH DETAILAS PER FIGURE 006
CONCRETE PAVINGAS PER FIGURE 010
002
STANDARD DRAWINGS FORSUBDIVISIONS IN GROWTH AREASACCESS PLACECROSS SECTION
1APR 2011
Revision
FigureDate
X:\Drawings & Graphics\Library\Engineering Design and Construction Manual\31-24931-FIG002 REV_1.dwgCad File No:12 April 2011 - 3:13 PMPlot Date: Gary MagnoPlotted by:
DateApprovedCheckedDrawnRevisionNo Note: * indicates signatures on original issue of drawing or last revision of drawing
4.0m(MIN)
4.0m(MIN)
R 4.0m R 4.0m
25.0m (MIN)
7.6m
7.0m
R 3.0m
R 3.0m
T TURNINGNOT TO SCALE
SIDE TURNING BAYNOT TO SCALE
IOK
IOK
IOK
IOK
NOTE:1. DESIGN VEHICLE 8.8m SERVICE VEHICLE IN
ACCORDANCE WITH AUSTROADS SPECIFICATIONS
CUL-DE-SACRESIDENTIAL SUBDIVISION
NOT TO SCALE
IOK
IOK
1.5m
R 0.5mR 0.5m
5.5m(MIN)
5.5m(MIN)
5.5m(MIN)
R10.5m R10.5m
R10.5m DES.
7.6m
005
STANDARD DRAWINGS FORSUBDIVISIONS IN GROWTH AREASTURNING AREA DETAILS
1APR 2011
Revision
FigureDate
X:\Drawings & Graphics\Library\Engineering Design and Construction Manual\31-24931-FIG005 REV_1.dwgCad File No:12 April 2011 - 3:14 PMPlot Date: Gary MagnoPlotted by:
DateApprovedCheckedDrawnRevisionNo Note: * indicates signatures on original issue of drawing or last revision of drawing
PROJECT
DRAWING No.OF
SHEET
REVDETAILS
ISSUE APPVD DATE AMENDMENT
DESIGN
DRAWN
DATE
CHECKED
SCALE
A
B
C
D
ENGINEERING SERVICES DEPT
PAPER
FILE NAMEMSC 703.DWG
A4
#### A
L.S.
FEB 09
L.S.
V.C.D.
STANDARD DRAWINGS - MSC 703
INDENTED PARKING BAY
N.T.S.
1 1
FTTH 1.775
0.400
0.050
0.400
1.500
SEWER 1.000
GAS 2.250
RECYCLED WATER 2.700
POTABLE WATER 3.200
PRO
PERT
Y BO
UNDA
RY
FOOTPATH
WATER/GASCORRIDOR
4.500
MAJOR SWD 450 DIA MAX. UNDER WSUDNODAL TREATMENT
0.850TYP
NATURESTRIP 2.800
PIT
BOK
SEP
4.200
FACE
OF
KERB
(B2
KERB
)
1.000 0.600
ELECTRICALCORRIDOR
PIT
FOOTPATH
PRO
PERT
Y BO
UNDA
RY
ELECTRICAL 2.600
FTTH 1.775
0.400
0.050
0.400
1.500NATURESTRIP 2.500
BOK
FTTH0.450
0.60
0
FTTH
LIG
HT P
OLE
S
TREE
S
6. FTTH HIGH SIDE (NON NETWORK SIDE)
NON NETWORK SIDE TYPICALLY CONSISTS OF ISOLATED PITS AT REGULARINTERVALS WITH CONNECTIONS TO THE NETWORK VIA ROAD CROSSINGS.HOWEVER IN SOME INSTANCES PITS MAY BE CONNECTED WITH CONDUITSSIMILAR TO NETWORK SIDE.
7. FTTH LOW SIDE (NETWORK SIDE)
NETWORK (DISTRIBUTION) SIDE CONSISTS OF CONDUIT RUNS ALONGSIDEROADS WITH PITS AT REGULAR INTERVALS FOR ACCESS TO THENETWORK AND FOR ROAD CROSSINGS TO THE NEW NETWORK SIDE
IN MOST INSTANCES THE NETWORK SIDE WILL BE ON THE SAME SIDE ASTHE ELECTRICAL DISTRIBUTION. HOWEVER THERE ARE EXCEPTIONS INWHICH THE NETWORK WILL BE RUN ON THE NON-ELECTRICAL SIDE.
FTTH NOTES:
1. ASSUME WATER 100mm CONDUIT AND GAS 50mm CONDUIT
2. ASSUME STORMWATER DRAINAGE PIT 600x900
3. LOCATE FTTH UNDER FOOTPATH WHERE STORMWATER DRAINAGE PITWIDTH GREATER THAN 600mm
4. ASSUME 1200mm RISER IN HAUNCHED STORMWATER DRAINAGE PIT
5. MAXIMUM 2xHV POWER CABLES IN 100mm ELECTRICAL CONDUITS AND2xHV POWER CABLES IN 120mm CONDUITS
SERVICES NOTES:
ELECGASREUSE WATER
0.450
FACE
OF
KERB
(B2
KERB
)
0.60
0
0.25Min.
003
STANDARD DRAWINGS FORSUBDIVISIONS IN GROWTH AREAS 1
APR 2011Revision
FigureDate
X:\Drawings & Graphics\Library\Engineering Design and Construction Manual\31-24931-FIG003 REV_1.dwgCad File No:12 April 2011 - 3:14 PMPlot Date: Gary MagnoPlotted by:
DateApprovedCheckedDrawnRevisionNo Note: * indicates signatures on original issue of drawing or last revision of drawing
FTTH 1.775
0.400
0.050
0.400
1.500
SEWER 1.200
GAS 2.250
RECYCLED WATER 2.675
POTABLE WATER 3.150
PRO
PERT
Y BO
UNDA
RY
FOOTPATH
WATER/GASCORRIDOR
4.500
MAJOR SWD 900Ø AND LARGERMIN COVER 0.600 IN NATURESTRIP
MIN COVER 0.900 UNDER PAVEMENT
0.850TYP
NATURESTRIP 2.800
PIT
BOK
4.200
FACE
OF
KERB
(B2
KERB
)
1.000 0.600
ELECTRICALCORRIDOR
PIT
FOOTPATH
PRO
PERT
Y BO
UNDA
RY
ELECTRICAL 2.600
FTTH 1.775
0.400
0.050
0.400
1.500NATURESTRIP 2.500
BOK
FTTH0.450
0.60
0
FTTH
LIG
HT P
OLE
S
TREE
S
2. FTTH HIGH SIDE (NON NETWORK SIDE)
NON NETWORK SIDE TYPICALLY CONSISTS OF ISOLATED PITS AT REGULARINTERVALS WITH CONNECTIONS TO THE NETWORK VIA ROAD CROSSINGS.HOWEVER IN SOME INSTANCES PITS MAY BE CONNECTED WITH CONDUITSSIMILAR TO NETWORK SIDE.
3. FTTH LOW SIDE (NETWORK SIDE)
NETWORK (DISTRIBUTION) SIDE CONSISTS OF CONDUIT RUNS ALONGSIDEROADS WITH PITS AT REGULAR INTERVALS FOR ACCESS TO THENETWORK AND FOR ROAD CROSSINGS TO THE NEW NETWORK SIDE
IN MOST INSTANCES THE NETWORK SIDE WILL BE ON THE SAME SIDE ASTHE ELECTRICAL DISTRIBUTION. HOWEVER THERE ARE EXCEPTIONS INWHICH THE NETWORK WILL BE RUN ON THE NON-ELECTRICAL SIDE.
FTTH NOTES:
ELECGASREUSE WATER
0.450
FACE
OF
KERB
(B2
KERB
)
0.60
0
0.600
SWD
1. LANDSCAPING REQUIRES SPECIAL CONSIDERATION WHENPOSITIONING ADJACENT TO MELBOURNE WATER MAIN DRAINS
NOTES:
1.000
004
STANDARD DRAWINGS FORSUBDIVISIONS IN GROWTH AREAS 1
APR 2011Revision
FigureDate
X:\Drawings & Graphics\Library\Engineering Design and Construction Manual\31-24931-FIG004 REV_1.dwgCad File No:12 April 2011 - 3:14 PMPlot Date: Gary MagnoPlotted by:
DateApprovedCheckedDrawnRevisionNo Note: * indicates signatures on original issue of drawing or last revision of drawing