q 23 and d can be measured accurately at the same time
DESCRIPTION
q 23 and d can be measured accurately at the same time. Hisakazu Minakata PUC -Rio U. Sao Paulo (with Pilar Coloma & Stephen Parke). n a = U a i n i. All the angles are measured !lepton CP phase d left. T2K-MINOS-DC-DB-RENO. solar+KamLAND. SK-atm+MINOS+T2K. - PowerPoint PPT PresentationTRANSCRIPT
q23 and d can be measured accurately at the same time
Hisakazu MinakataPUC-Rio U. Sao Paulo
(with Pilar Coloma & Stephen Parke)
Sep. 17, 2013 WIN2013@Natal
All the angles are measured !lepton CP phase d left
na=Uai ni
solar+KamLANDSK-atm+MINOS+T2K T2K-MINOS-DC-DB-RENO
Sep. 17, 2013 WIN2013@Natal
New paradigm emerged!
WIN2013@Natal
Parameter determination: old paradigm
Sep. 17, 2013
Disappearance measurement determines q23 up to the octant
And then, ne and ne-bar appearance measurement determines q13 and d q23 , q13 and d up to 8-fold parameter degeneracy
WIN2013@Natal
But now q13 is measured accurately
Sep. 17, 2013
Daya Bay 2012
RENO 2013
WIN2013@Natal
q12 and q13
• sin2q12 = 0.304 +/- 0.013
• Error of sin2q12 = 4.3%
• Error of Dm221 = 2.4%
• Error of sin2q13 (Daya Bay) = 9.6%
• Error of Dm231 (Daya Bay) ~= 8%
• Error of Dm231 (MINOS) ~= 4%Sep. 17, 2013
KamLAND+solar Mar.2013
Sep. 17, 2013 WIN2013@Natal
q23 is now the least accurately measured angle
WIN2013@Natal
q23: mixing angle with the largest error of 10-20% level
Sep. 17, 2013Concha etal. JHEP 2012
WIN2013@Natal
Error of q23 is, and will remain large because ..
• Jacobian effect:
• Octant degeneracy + exp. uncertainty merging of clone solution to the true one
Sep. 17, 2013
HM-Sonoyama-Sugiyama PRD 2004
Sep. 17, 2013 WIN2013@Natal
We are in the new paradigm
!
WIN2013@Natal
It is likely that q23 is so large that disappearance measurement does not
distinguish q23 octant
Sep. 17, 2013
D (sin2q23) ~ 10-20%
D (sin2q13) can go down to 5%
WIN2013@Natal
We need a new setting !
• The right framework is then: “given the known value of q13 , determine q23 and d at the same time !”
• This is merely a new way of thinking, which must be considered before when reactor measurement of q13 was proposed!
Sep. 17, 2013
HM-S.Parke PRD 2013
Mikaelyan-Sinev 2000, HM-Sugiyama-Yasuda-Inoue-Suekane PRD 2003
Sep. 17, 2013 WIN2013@Natal
Appearance first: A new way
of thinking for q23 and
d
WIN2013@Natal
Continuous “appearance degeneracy” containing q13 and q23
Sep. 17, 2013
If we consider only appearance measurement continuous degeneracy of q23 and q13
Fixing q23 gives “intrinsic q13 degeneracy” and vice versa
Disappearance measurement yields generally the 2 bands at s2
23 = sin2qeff + s213/2,
s223 = cos2qeff + s2
13/2, but 2 bands fuse into a single region at near maximal q23
WIN2013@Natal
When q13 is measured accurately, the degeneracy becomes
Sep. 17, 2013
“q23 intrinsic degeneracy”
More precisely, “q23 intrinsic degeneracy duplicated by the unknown sign of Dm2”
Looks similar to q13 intrinsic degeneracy, but not quite same size ellipses
WIN2013@Natal
Nature of the degeneracy again
Sep. 17, 2013
If sin2q23 is near maximal, neither appearance measurement nor disappearance measurement (unless extremely precise) determines q23 ! (appearance and disappearance degeneracies overlap)
“Appearance and disappearance q23 degeneracies”
If q23 is far off maximal, accurate measurement of Pem-Pembar determines q23 (including octant) up to intrinsic q23 degeneracy (precision disapp. measurement can solve the degeneracy)
Sep. 17, 2013 WIN2013@Natal
1st vacuum
oscillation maximum
WIN2013@Natal
1st Oscillation maximum
Sep. 17, 2013
Things are much simpler in oscillation maximum
WIN2013@Natal
1st Oscillation maximum (continued)
Sep. 17, 2013
Things are much simpler in oscillation maximum
HM-S.Parke PRD 2013
Sep. 17, 2013 WIN2013@Natal
Breaking the q23
degeneracy
WIN2013@Natal
Breaking q23– d degeneracy
Sep. 17, 2013
At 1st VOM
Spectrum information must solve the degeneracy!
Off 1st VOM
Hyper-K: DE= +/- 10%: LBNE: DE= +/- 20%:
WIN2013@Natal
2nd vacuum oscillation maximum
Sep. 17, 2013
At 2nd VOM, D=3p/2
DE= +/- 3%: Movement of clone solution is more prominent at 2nd VOM
Sep. 17, 2013 WIN2013@Natal
Appearance vs.
disappearance
WIN2013@Natal
Interplay between appearance and disappearance measurement
Sep. 17, 2013
T2HK LBNE
P.Coloma, HM, S.Parke, in progress
WIN2013@Natal
Conclusion
• Given the fact that q13 is measured accurately and the error will be much less in near future, a new strategy for determining q23 and d is called for
• Correlated simultaneous determination q23 and d by using appearance channels outlined
• q23 degeneracy and how to break it discussed• Near maximal q23, we need to understand
interplay between appearance and disappearance measurement
Sep. 17, 2013
WIN2013@Natal
Simultaneous q23– d determination
Sep. 17, 2013
For a given set of (P, P-bar) there are 2x2=4 solutions of q23 and d
What you need is to switch q13 q23
everything goes through as in (q13-d) case except for the “same-size ellipses”