punching stress aci
TRANSCRIPT
-
7/22/2019 Punching Stress Aci
1/20
Check of Punching Shear in Flat Slabs and Rafts under N, M According to ACI 318-02 by wae
Columns (REC.or CIRCULAR)
Building: S.S.BUILDING Column: FRAME ( ) - JOINT ( )
Slab
Slab thickness = ts 300.00 mm
Concrete Cover = d` 30.00 mm
Critical thickness = d 270.00 mm
Straining Actions
Un-balanced Moment :-
Mu1 = 35.75 KN.m added t
Mu2 = 158.15 KN.m added t
Ultimate Shear force:-
Pu = 463.75 KN
Column Dimensions:
C1= 500.00 mm
C2= 450.00 mm bc=C1
D= 500.00 mm bc=D/D
as= 40.00 (20 for
d/2= 135.00 mm
Materials
Slab Concrete Grade = 43.75 Mpa
Reinforcement Steel Grade= 420.00 Mpa
Critical section in punching:- TYPE(1)
b1=C1+d 770.00 mm
b2=C2+d 720.00 mm
2980.00 mm
Flexural portion of moment (gf)=1/1+(2/3)b1/b2 0.59
Eccentric shear portion (v)=1-f 0.41
Critical section in punching:- TYPE(2)
b1=D+d 770.00 mm
b2=D+d 770.00 mm
bo= 2b = 4835.60 mm
Flexural portion of moment (gf)=1/1+(2/3)D/D 0.60
Eccentric shear portion (v)=1-f 0.40
Shear/Torsion Parameters
Shear/Torsion resisting Parameters according to ACI318-02, R11.12.6.3
c=b1^2/(2b1+b2)or(c`=D+d/2)= 635.00 mm
635.00 mm
Ac= 0.65 m2
Bending MU1 0.35 m3
OTHER DIRECTION C1 0 b1= 270.00 mm
C2 0 b2= 270.00 mm
bo= 2b1 +2 b2 = 1080.00 mm
Flexural portion of moment (gf)=1/1+(2/3)b1/b2 0.60
Eccentric shear portion (v)=1-f 0.40
Shear/Torsion Parameters
bo= 2b1 +2 b2 =
Jcn/c=(Jcn/c')or(J/c)
c'=( b1-c) or(c=c`)=
-
7/22/2019 Punching Stress Aci
2/20
CALCULATION OF REQUIRED SHEAR REINFORCEMENT
Shear force in reinforcement
Check if (vu) is less than (f6 sqrt(fc') ) or not
vu= 933.0028163 f6 sqrt(fc')= 2218.529919 O
fvc(for punching RFT=2SQRT(fc')= 739.51 KN/M2
Shear force to be resisted by reinforcement
Vs=bod *(vu-fvc(min))= 56.42 KN
Required Reinforcement
Total area of steel on 4 sides of column is given by
Av= Vs* S / (f*fy*d)Stirrups Spacing (s) = 75 mm
number of legs = 2
Av = 4.97553E-05 m2= 49.76 mm
2
Av/Side = 12.43882565 mm2
Then use, Vl U-bars T 3
Distribution of shear RFT
Determination of distance from column face for termination of stirrups
stirrups are not required when, Vuis less than fvc(min) bo'*d
then, bo'= 1362.582086 mm
bo'= 2C1 + 2C2 + 4 a Sqrt(2), where a is the extension of shear RFT from face of colum
a = (bo'-2C1-2C2)/4Sqrt(2)
a = -95.0029628 mm
Design Report
SLAB THICKNESS IS OK WITHOUT ANY ADDITIONAL SHEAR REINFORCEMENT
use RFT of T 3 @ 75.00 2 le
for a distance -50 mm from each side of support
s
a2
C1
bo'a
-
7/22/2019 Punching Stress Aci
3/20
Check of Punching Shear in Flat Slabs and Rafts under N, Mx, and My According to ACI 318-02
For Edge Columns (3 sides only)
Building: AREEN Column: Edge column L16 to L24 Comb(
C3 AT AXES(6)&(C)
Slab
Slab thickness = 200 mm
Concrete Cover = 38 mm
Straining Actions
Un-balanced Moment
Mu1(perp.)= 0 KN.m added to N at inner sid
Mu2(perp.) 100.79 KN.m added to N at outer sid
Mu (parllel) 51.41 KN.m
Ultimate Shear force= 120.8 KN
Column Dimensions:
C1= 800 mm
C2= 480 mm bc= 1.66667
as= 30 (20 for corner, 30 for e
edge distance (e)= 150 mm
Materials
Slab Concrete Grade = 45 Mpa
Reinforcement Steel Grade= 460 Mpa
Critical section in punching:
b1= 1031 mm
b2= 642 mm
bo= 2b1 +b2 = 2704 mm
Flexural portion of moment (gf)= 0.5420547
Eccentric shear portion (gv)= 0.4579453
Shear/Torsion Parameters
Shear/Torsion resisting Parameters according to ACI318-02, R11.12.6.3
c=b1^2/(2b1+b2)= 393.10688 mm
c'= b1-c= 637.89312 mm
Ac= 0.438048 m2
Bending normal to edge: Jcn= 0.0513963 m4
Jcn=[2b1
Bending Parllel to edge: Jcp= 0.0382199 m4
Jcp=b2/2*
Edge o
N.A.
c'
c
Effective punching area
-
7/22/2019 Punching Stress Aci
4/20
Ultimate Shear Stress
Ultimate shear force
V/A= 275.76887
Mn*c/Jcn= 0
Mn*c'/Jcn= 0 473.501 78.03702
Mp*b2/2/Jcp= 197.73185
Ultimate shear stress vu= 473.50071 Kpa Inner corner=Vu/Ac+gv
78.03702
or = 1046.3594 Kpa Outer corner=Vu/Ac+gv
Critical Ultimate shear stress = 1046.3594 KPa
Concrete Punching Strength:
f = 0.75
fvc(1)= 1650 Kpa
fvc(2)= 1424.0015 Kpafvc(3)= 1500 Kpa
fvc(min)= 1424.0015 Kpa
Is (vu)less than fvc(min) ? Yes, OK SAFE, STOP AT THIS STAGE
CALCULATION OF REQUIRED SHEAR REINFORCEMENT
Shear force in reinforcement
Check if (vu) is less than (f6 sqrt(fc') ) or not
vu= 1046.35942 f6 sqrt(fc') 2250 OK, Slab
fvc(for punching RFT=2SQRT(fc')= 750 Kpa
Shear force to be resisted by reinforcement
Vs=bod *(vu-fvc(min))= 129.81965 KN
Required Reinforcement
Total area of steel on three sides of column is given by
Av= Vs* S / (f*fy*d)
Stirrups Spacing (s) = 100 mm
number of legs = 6
Av = 0.00023228 m2= 232.27707 mm
2
Av/Side = 77.4256889 mm2
Then use, Vl U-bars T 5
Distribution of shear RFT
-
7/22/2019 Punching Stress Aci
5/20
Determination of distance from column face for termination of stirrups
stirrups are not required when, Vuis less than fvc(min) bo'*d
then, bo'= 3674.01101 mm
bo'= 2C1 + C2 + 2 a Sqrt(2), where a is the extension of shear RFT from fa
a = (bo'-2C1-C2)/2Sqrt(2)
a = 563.567998 mm
Design Report
SLAB THICKNESS IS OK WITHOUT ANY ADDITIONAL SHEAR REINFORCEMENT
use RFT of T 5 @ 100 6 legs
for a distance 600 mm from each side of support
s
a2
C1
C2
bo'
a
a
Punching Shear Reinforcement DetailsFrom "Notes on ACI318-02, pp16-27"
-
7/22/2019 Punching Stress Aci
6/20
1)
ge and 40 for interior col)
2*d*(b1+2b2)+d^3*(2b1+b2)]*c/6b1
(b2*d(b2+6b1)+d^3)/6
from "Notes on ACI318-02, pp 16-16"
C2
C1
slab
b2=c2+d
b1=c1+d/2+e
e
d/2
-
7/22/2019 Punching Stress Aci
7/20
Mu1(perp)*c/Jcn+ gvMu(parallel)*(b2/2)/Jcp
Mu2(perp)*c'/Jcn+ gvMu(parallel)*(b2/2)/Jcp
thickness is adequate
@ 100
-
7/22/2019 Punching Stress Aci
8/20
e of column
-
7/22/2019 Punching Stress Aci
9/20
Check of Punching Shear in Flat Slabs and Rafts under N, Mx, and My According to ACI 318-02
For Edge Columns (3 sides only)
Building: AREEN Column: Edge column L16 to L24 Comb(
C3 AT AXES(6)&(C)
Slab
Slab thickness = 200 mm
Concrete Cover = 38 mm
Straining Actions
Un-balanced Moment
Mu1(perp.)= 37.39 KN.m added to N at inner sid
Mu2(perp.) 0 KN.m added to N at outer sid
Mu (parllel) 15.04 KN.m
Ultimate Shear force= 105.6 KN
Column Dimensions:
C1= 800 mm
C2= 480 mm bc= 1.66667
as= 30 (20 for corner, 30 for e
edge distance (e)= 150 mm
Materials
Slab Concrete Grade = 45 Mpa
Reinforcement Steel Grade= 460 Mpa
Critical section in punching:
b1= 1031 mm
b2= 642 mm
bo= 2b1 +b2 = 2704 mm
Flexural portion of moment (gf)= 0.5420547
Eccentric shear portion (gv)= 0.4579453
Shear/Torsion Parameters
Shear/Torsion resisting Parameters according to ACI318-02, R11.12.6.3
c=b1^2/(2b1+b2)= 393.10688 mm
c'= b1-c= 637.89312 mm
Ac= 0.438048 m2
Bending normal to edge: Jcn= 0.0513963 m4
Jcn=[2b1
Bending Parllel to edge: Jcp= 0.0382199 m4
Jcp=b2/2*
Edge o
N.A.
c'
c
Effective punching area
-
7/22/2019 Punching Stress Aci
10/20
Ultimate Shear Stress
Ultimate shear force
V/A= 241.06947
Mn*c/Jcn= 130.96289
Mn*c'/Jcn= 212.51302 429.879 -29.290016
Mp*b2/2/Jcp= 57.846469
Ultimate shear stress vu= 429.87884 Kpa Inner corner=Vu/Ac+gv
-29.29002
or = 298.91594 Kpa Outer corner=Vu/Ac+gv
Critical Ultimate shear stress = 429.87884 KPa
Concrete Punching Strength:
f = 0.75
fvc(1)= 1650 Kpa
fvc(2)= 1424.0015 Kpafvc(3)= 1500 Kpa
fvc(min)= 1424.0015 Kpa
Is (vu)less than fvc(min) ? Yes, OK SAFE, STOP AT THIS STAGE
CALCULATION OF REQUIRED SHEAR REINFORCEMENT
Shear force in reinforcement
Check if (vu) is less than (f6 sqrt(fc') ) or not
vu= 429.878835 f6 sqrt(fc') 2250 OK, Slab
fvc(for punching RFT=2SQRT(fc')= 750 Kpa
Shear force to be resisted by reinforcement
Vs=bod *(vu-fvc(min))= -140.2284 KN
Required Reinforcement
Total area of steel on three sides of column is given by
Av= Vs* S / (f*fy*d)
Stirrups Spacing (s) = 100 mm
number of legs = 6
Av = -0.0002509 m2= -250.9008 mm
2
Av/Side = -83.633587 mm2
Then use, Vl U-bars T #NUM!
Distribution of shear RFT
-
7/22/2019 Punching Stress Aci
11/20
Determination of distance from column face for termination of stirrups
stirrups are not required when, Vuis less than fvc(min) bo'*d
then, bo'= 1509.40446 mm
bo'= 2C1 + C2 + 2 a Sqrt(2), where a is the extension of shear RFT from fa
a = (bo'-2C1-C2)/2Sqrt(2)
a = -201.73599 mm
Design Report
SLAB THICKNESS IS OK WITHOUT ANY ADDITIONAL SHEAR REINFORCEMENT
use RFT of T #NUM! @ 100 6 legs
for a distance -200 mm from each side of support
s
a2
C1
C2
bo'
a
a
Punching Shear Reinforcement DetailsFrom "Notes on ACI318-02, pp16-27"
-
7/22/2019 Punching Stress Aci
12/20
1)
ge and 40 for interior col)
2*d*(b1+2b2)+d^3*(2b1+b2)]*c/6b1
(b2*d(b2+6b1)+d^3)/6
from "Notes on ACI318-02, pp 16-16"
C2
C1
slab
b2=c2+d
b1=c1+d/2+e
e
d/2
-
7/22/2019 Punching Stress Aci
13/20
Mu1(perp)*c/Jcn+ gvMu(parallel)*(b2/2)/Jcp
Mu2(perp)*c'/Jcn+ gvMu(parallel)*(b2/2)/Jcp
thickness is adequate
@ 100
-
7/22/2019 Punching Stress Aci
14/20
e of column
-
7/22/2019 Punching Stress Aci
15/20
Check of Punching Shear in Flat Slabs and Rafts under N, Mx, and My According to ACI 318-02
For Edge Columns (3 sides only)
Building: AREEN Column: Edge column L16 to L24 Comb(
C3 AT AXES(6)&(C)
Slab
Slab thickness = 200 mm
Concrete Cover = 38 mm
Straining Actions
Un-balanced Moment
Mu1(perp.)= 26.11 KN.m added to N at inner sid
Mu2(perp.) 0 KN.m added to N at outer sid
Mu (parllel) 126.17 KN.m
Ultimate Shear force= 175 KN
Column Dimensions:
C1= 800 mm
C2= 480 mm bc= 1.66667
as= 30 (20 for corner, 30 for e
edge distance (e)= 150 mm
Materials
Slab Concrete Grade = 45 Mpa
Reinforcement Steel Grade= 460 Mpa
Critical section in punching:
b1= 1031 mm
b2= 642 mm
bo= 2b1 +b2 = 2704 mm
Flexural portion of moment (gf)= 0.5420547
Eccentric shear portion (gv)= 0.4579453
Shear/Torsion Parameters
Shear/Torsion resisting Parameters according to ACI318-02, R11.12.6.3
c=b1^2/(2b1+b2)= 393.10688 mm
c'= b1-c= 637.89312 mm
Ac= 0.438048 m2
Bending normal to edge: Jcn= 0.0513963 m4
Jcn=[2b1
Bending Parllel to edge: Jcp= 0.0382199 m4
Jcp=b2/2*
Edge o
N.A.
c'
c
Effective punching area
-
7/22/2019 Punching Stress Aci
16/20
Ultimate Shear Stress
Ultimate shear force
V/A= 399.4996
Mn*c/Jcn= 91.453361
Mn*c'/Jcn= 148.40104 976.225 -234.17332
Mp*b2/2/Jcp= 485.27187
Ultimate shear stress vu= 976.22483 Kpa Inner corner=Vu/Ac+gv
-234.1733
or = 884.77147 Kpa Outer corner=Vu/Ac+gv
Critical Ultimate shear stress = 976.22483 KPa
Concrete Punching Strength:
f = 0.75
fvc(1)= 1650 Kpa
fvc(2)= 1424.0015 Kpafvc(3)= 1500 Kpa
fvc(min)= 1424.0015 Kpa
Is (vu)less than fvc(min) ? Yes, OK SAFE, STOP AT THIS STAGE
CALCULATION OF REQUIRED SHEAR REINFORCEMENT
Shear force in reinforcement
Check if (vu) is less than (f6 sqrt(fc') ) or not
vu= 976.224832 f6 sqrt(fc') 2250 OK, Slab
fvc(for punching RFT=2SQRT(fc')= 750 Kpa
Shear force to be resisted by reinforcement
Vs=bod *(vu-fvc(min))= 99.097335 KN
Required Reinforcement
Total area of steel on three sides of column is given by
Av= Vs* S / (f*fy*d)
Stirrups Spacing (s) = 100 mm
number of legs = 6
Av = 0.00017731 m2= 177.30781 mm
2
Av/Side = 59.1026034 mm2
Then use, Vl U-bars T 4
Distribution of shear RFT
-
7/22/2019 Punching Stress Aci
17/20
Determination of distance from column face for termination of stirrups
stirrups are not required when, Vuis less than fvc(min) bo'*d
then, bo'= 3427.75217 mm
bo'= 2C1 + C2 + 2 a Sqrt(2), where a is the extension of shear RFT from fa
a = (bo'-2C1-C2)/2Sqrt(2)
a = 476.502349 mm
Design Report
SLAB THICKNESS IS OK WITHOUT ANY ADDITIONAL SHEAR REINFORCEMENT
use RFT of T 4 @ 100 6 legs
for a distance 500 mm from each side of support
s
a2
C1
C2
bo'
a
a
Punching Shear Reinforcement DetailsFrom "Notes on ACI318-02, pp16-27"
-
7/22/2019 Punching Stress Aci
18/20
1)
ge and 40 for interior col)
2*d*(b1+2b2)+d^3*(2b1+b2)]*c/6b1
(b2*d(b2+6b1)+d^3)/6
from "Notes on ACI318-02, pp 16-16"
C2
C1
slab
b2=c2+d
b1=c1+d/2+e
e
d/2
-
7/22/2019 Punching Stress Aci
19/20
Mu1(perp)*c/Jcn+ gvMu(parallel)*(b2/2)/Jcp
Mu2(perp)*c'/Jcn+ gvMu(parallel)*(b2/2)/Jcp
thickness is adequate
@ 100
-
7/22/2019 Punching Stress Aci
20/20
e of column