pumps and automation 2011 - bombas · pdf filetype series index for pumps and automation hgb /...
TRANSCRIPT
Pumps n Valves n Systems
Pumps and Automation 2011
O u r h i g h s t a n d a r d :
C r e a t i n g i n t e l l i g e n t s o l u t i o n s
We have supplied generations of
customers worldwide with pumps, valves,
automation products and services.
A company with that kind of experience
knows that success never stands still.
It flows. And the process that makes
that possible is a running partnership
between developer and user, between
production and practice.
Partners move more together. We
do everything possible to ensure that
our customers always have access to the
ideal product and system solutions. KSB
is a loyal partner. And a strong one:
• Over 130 years’ experience
• Present in more than 100 countries
• More than 14,200 employees
• More than 100 service centres
worldwide
• Approximately 1,900 service specialists
T y p e s e r i e s i n d e x p . 3
P r o d u c t p o r t f o l i o p . 6 - 7
O v e r v i e w o f a p p l i c a t i o n s p . 8 - 1 5
3
T y p e s e r i e s i n d e x
for pumps and automation
HGB / HGC / HGD 46HGM 46HGM-RO 50HHD 40HK (Nikkiso-KSB) 25HN/BN/TN (Nikkiso-KSB) 25HPH 21HPK 21HPK-L 21HT/BT/TT (Nikkiso-KSB) 25 HX (Nikkiso-KSB) 22HY (Nikkiso-KSB) 23 Hya-Eco K 30Hya-Eco VP 30Hyamaster ISB 52Hyamaster SPS 52Hyamat IK, IV, IVP 31Hyamat K 30Hyamat V 30Hyamat VP 30Hya-Rain / Hya-Rain N 27Hya-Rain Eco 27Hya-Solo E 29Hya-Solo D 29Hya-Solo DV 29hyatronic N 51hyatronic mb 52hyatronic spc 52 Ixo 28 KWP / KWP-Bloc 38
LCC-M 38LCC-R 39LCV 39Level Control 51LHD 40LSA-S 38LSR 39LUV / LUVA 47LUV-Nuclear 48 Magnochem 24Magnochem-Bloc 24Mega 40MDX 40MHD 40Microchem 27mini-Compacta 33MK / MKY 32Movitec PumpDrive 43Movitec VME 28Movitec V / LHS / VS / VC 43Multi Eco 28Multi Eco-Pro 28Multi Eco-Top 28Multitec 43Multitec PumpDrive 43Multitec-RO 50
Omega 44
PSR 48PumpDrive 52Pumping Station CK 800-Eu 33PumpMeter 53
RDLO 44RER 48RHD 46RHM 48RHR / RVR 49Rio 16 Rio C 16Rio Z 16Rio-Eco 17Rio-Eco B 17Rio-Eco Z 17Riotherm 16Riotherm C 16Riotronic Eco 17Riotronic P 17Rotex 32RPH 26RPH-RO 50RSR 48RUV 49RVM 49 S 100D / UPA 100C 42SalTec System 50SalTec DT 50Secochem Ex 24Secochem Ex K 25Sewatec / Sewabloc 37SEZ / SEZT / PHZ / PNZ 47SNW / PNW 47SPY 47
TBC 39
UPA 150C 42UPA 200, 200B, 250C 42UPA 300, 350 42UPA Control 51UPZ, BSX-BSF 42
Vitachrom 44Vitacast / Vitacast E 44Vitalobe 45Vitaprime 45Vitastage 45 VN (Nikkiso-KSB) 25
WBC 38WKT / WKTA / WKTB 47
YNK / KRHA 46
ZW 41
Amacan K 36Amacan P 36Amacan S 36Amacontrol 53Ama-Drainer-Box 33Ama-Drainer N 301 – 358 31Ama-Drainer 400 – 500 31Ama-Drainer 80, 100 31Amajet 37Amaline 37Amamix 36Ama-Porter F / S / ICS 32Ama-Porter CK Pumping Station 34Amaprop 37Amarex KRT 35Amarex KRT dry-installed 35Amarex KRT wet/dry-installed 35Amarex N 35Amarex N CK Pumping Station 34API series (Nikkoso-KSB) 26
Cervomatic EDP.2 51CHTA / CHTC / CHTD 45CHTR 46Compacta 33Controlmatic E.2 51CPK-D 23CPKN 23CPKN PumpDrive 23CTN 26
DN (Nikkiso-KSB) 26
Etabloc 19Etabloc Pump Drive 20Etabloc SYT / Etaline SYT 22Etachrom BC 20 Etachrom BC PumpDrive 20Etachrom NC 20 Etachrom NC PumpDrive 20Etaline 18Etaline PumpDrive 18Etaline-R 19Etaline Z 18Etaline Z PumpDrive 18Etamagno SY / SYI / Bloc SY 22Etanorm / Etanorm-R 19Etanorm Pump Drive 19 Etanorm GPV / CPV 21Etanorm SYT / RSY 22Etaprime B / BN 41Etaprime L 41Etaseco / Etaseco-I 24Etaseco RVP 24Evamatic-Box 34Evamatic-Box ICS 34
Filtra N 29FGD 39
4
O u r s e r v i c e s :
D e p e n d a b i l i t y a t y o u r c a l l
We tailor our services to enable
new ways of individually optimizing
our products. They underscore our far-
reaching sense of customer responsibil-
ity. That commitment starts before any
orders – for example with sound advice
on financing options. And it goes far
beyond product arrival. A dependable
partnership with KSB lasts for years. Our
services to customers include:
• Remote diagnosis
• Revamping
• TPM® (Total Pump Management)
• System engineering
• Advice on life cycle costs
• Financing options
• Teleservice
• Savings potential analysis
Ready where you are. KSB runs
more than 100 service centres around
the world. Some 1,900 highly trained
KSB specialists are on call to inspect
and maintain your equipment. So you
can plan for a future free of unwanted
surprises. And we also provide individual
on-site training sessions. They ensure
that operators can use KSB products and
systems efficiently and profitably, day in,
day out.
Which is how we secure the long-term
value of our customers’ facilities.
5
O u r v i s i o n :
M o v i n g m o r e , t o g e t h e r
Yesterday: Movement with a
mission.
When KSB started business in 1871, our
pumps got things moving almost over-
night. From the word go, the company
was an enthusiastic pioneer. The motor
of that dynamism was the sense of con-
tributing to new movement in modern
industry.
That is all history now. But KSB still stays
true to its tradition, and continues to
pioneer remarkable technical skills.
Today: Impetus from innovations.
KSB has spent its long history providing
technical innovations that help custom-
ers and partners work more successfully
than ever.
We gear everything we do to the
real demands of everyday operations.
Products, systems, life cycle costs and
our steadily growing range of services all
put customers and their processes first.
This relies on our special concentration
of activities – from development to sales
and marketing.
Tomorrow: Perspectives for
partnerships.
Lively dialogue with customers has been
a KSB speciality for over 130 years.
Mutual respect remains its hallmark.
Our aim is to strengthen this working
partnership still further. The benefits
are mutual, too: we profit from prac-
tical experience that complements our
years of development know-how. And
so our customers profit from innovative
products, systems and services that
match their demands with precision and
perform ance.
Partnership is a value whose products keep their value. So moving more together makes doubly good sense. We look
forward to teaming up.
6
Automation possibleFactory-automated
Type / Application Type series Page A
Circulator pumps/hot water service pumps, fixed speed
Rio C / Rio / Rio Z / Riotherm C 16 n n
Riotherm 16 n n n
Circulator pumps, variable speed Riotronic P 17 n n
Riotronic Eco 17 n n n
Rio-Eco / Rio-Eco B / Rio-Eco Z 17 n n n
In-line pumps with fixed/variable speed drive
Etaline / Etaline Z 18 n n n
Etaline PumpDrive / Etaline Z PumpDrive 18 n n n n
Etaline-R 19 n n n
Standardized/close-coupled pumps, fixed/variable speed
Etanorm / Etanorm-R 19 n n n n n
Etanorm PumpDrive 19 n n n n n
Etabloc 19 n n n n n
Etabloc PumpDrive 20 n n n n n
Etachrom BC 20 n n n n n
Etachrom BC PumpDrive 20 n n n n n
Etachrom NC 20 n n n n n
Etachrom NC PumpDrive 20 n n n n n
Etanorm GPV / CPV 21 n n n n
Hot water pumps HPK-L / HPK / HPH 21 n n n n
Hot water/thermal oil pumps Etanorm SYT / RSY 22 n n n
Etabloc SYT / Etaline SYT 22 n n n
Thermal oil pumps with magnetic drive / canned motor
Etamagno SY / SYI / Bloc SY 22 n n
HX (Nikkiso-KSB) 22 n
HY (Nikkiso-KSB) 23 n
Standardized chemical pumps CPKN 23 n n n
CPKN PumpDrive 23 n n n
CPK-D 23 n n
Seal-less pumps Magnochem 24 n n n
Magnochem-Bloc 24 n n
Etaseco / Etaseco-I 24 n n n n n
Etaseco RVP 24 n n n n n
Secochem Ex 24 n n n
Secochem Ex K 25 n n n
HN / BN / TN (Nikkiso-KSB) 25 n n
HT / BT / TT (Nikkiso-KSB) 25 n n
HK (Nikkiso-KSB) / VN (Nikkiso-KSB 25 n n
DN (Nikkiso-KSB) 26 n
Process pumps RPH 26 n n n
CTN 26 n
API series (Nikkiso-KSB) 26 n
Centrifugal pump for minimal volume flows Microchem 27 n n
Rainwater harvesting systems Hya-Rain / Hya-Rain N 27 n n n
Hya-Rain Eco 27 n n n
Domestic water supply systems with automatic control unit/swimming pools
Multi Eco 28 n n n n
Multi Eco-Pro 28 n n
Multi Eco-Top 28 n n n n
Movitec VME 28 n n n n
Ixo 28 n n n n
Filtra N 29 n
Pressure booster systems Hya-Solo E / D / DV 29 n n n n
Hya-Eco K / Hya-Eco VP 30 n n n n
Hyamat K / Hyamat V / Hyamat VP 30 n n n n
Hyamat IK, IV, IVP 31 n n n
Drainage pumps/waste water pumps Ama-Drainer N 301, 302, 303, 358 31 n n
Ama-Drainer 400/10 400/35 500/10/11 31 n n n
Ama-Drainer 80, 100 31 n n
Ama-Porter F / S 32 n n
Ama-Porter ICS 32 n n
Rotex 32 n n
MK / MKY 32 n n n
Lifting units/collection tanks Ama-Drainer-Box 33 n n
mini-Compacta 33 n n
Compacta 33 n n n
Pumping Station CK 800-Eu 33 n n
Ama-Porter CK Pumping Station 34 n n
Amarex N CK Pumping Station 34 n n
Evamatic-Box 34 n
Evamatic-Box ICS 34 n n
Submersible motor pumps Amarex N 35 n n n n
Amarex KRT 35 n n n n
Amarex KRT dry-installed 35 n n n n
Amarex KRT wet/dry-installed 35 n n n n
Wat
er T
rans
port
an
d Tr
eatm
ent
Indu
stry
Ener
gy C
onve
rsio
n
Build
ing
Serv
ices
Solid
s Tr
ansp
ort
Auto
mat
ion
7
Type / Application Type series Page A
Submersible pumps in discharge tubes Amacan K / Amacan P / Amacan S 36 n n
Mixers/agitators/tank cleaning units Amamix, 36 n n
Amaprop, Amajet, Amaline 37 n n
Pumps for solids-laden fluids Sewatec / Sewabloc 37 n n n
KWP / KWP-Bloc 38 n n n n
Slurry pumps WBC 38 n
LSA-S 38 n n n
LCC-M 38 n n n
LCC-R 39 n n n
TBC 39 n
LSR / LCV 39 n
FGD 39 n n n
Mega 40 n
HHD 40 n
MHD 40 n
LHD 40 n
MDX 40 n n
ZW 41 n
Self-priming pumps Etaprime L / Etaprime B / BN 41 n n
Submersible borehole pumps S 100D / UPA 100C 42 n n n n
UPA 150C, 200, 200B, 250C, 300, 350 42 n n n
UPZ, BSX-BSF 42 n n n n
High-pressure pumps, fixed/variable speed Movitec V / LHS / VS / VC 43 n n n n n
Movitec PumpDrive 43 n n n n n
Multitec 43 n n n n n
Multitec PumpDrive 43 n n n n n
Axially split pumps Omega 44 n n n n n
RDLO 44 n n n n n
Hygienic pumps for the food, beverage and pharmaceutical industries
Vitachrom / Vitacast / Vitacast E 44 n n
Vitaprime / Vitastage / Vitalobe 45 n n
Pumps for power station conventional islands
CHTA / CHTC / CHTD 45 n
CHTR 46 n
HGB / HGC / HGD 46 n n
HGM 46 n n
YNK / KRHA 46 n
RHD 46 n
LUV / LUVA 47 n
WKT / WKTA / WKTB 47 n
SEZ / SEZT / PHZ / PNZ 47 n n
SNW / PNW 47 n n
SPY 47 n n n
Pumps for power station nuclear islands RER / RSR / PSR 48 n
LUV-Nuclear / RHM 48 n
RVM / RHR / RVR / RUV 49 n
Pumps and pressure exchangers for seawater desalination by reverse osmosis
SalTec System 50 n n
SalTec DT 50 n n
RPH-RO 50 n
HGM-RO 50 n
Multitec-RO 50 n n
Control units Controlmatic E.2 51 n n
Cervomatic EDP.2 51 n n
LevelControl 51 n n
UPA Control 51 n n
hyatronic N 51 n n n
Speed control PumpDrive 52 n n n
hyatronic spc 52 n n n
hyatronic mb 52 n n n
Hyamaster ISB 52 n n n
Hyamaster SPS 52 n n n
Monitoring and diagnostic systems PumpMeter 53 n n
Amacontrol 53 n n
Automation Page
Automation possibleFactory-automated
Wat
er T
rans
port
an
d Tr
eatm
ent
Indu
stry
Ener
gy C
onve
rsio
n
Build
ing
Serv
ices
Solid
s Tr
ansp
ort
Auto
mat
ion
8
Activated sludgeAggressive liquids
Brackish waterBrine
Cleaning agentsCondensate
CoolantCooling water
Corrosive liquidsDestillate
Digested sludgeDipping paintsDrinking water
Explosive liquidsFeed water
Fire-fighting waterFlammable liquids
FuelsGas-containing liquids
Harmful liquidsHeating water
Highly aggressive liquidsHigh-temperature hot water
Hot waterHygienic liquids
Industrial service waterInorganic liquids
Liquefied gasLubricants
OilsOrganic liquids
Polymerizing liquidsRaw sludge
River, lake and ground waterSeawater
Service waterSewage with faeces
Sewage without faecesSlurries
Slurries (ore, sand, gravel, ash)Solvents
Swimming-pool waterThermal oil
Toxic liquidsValuable liquidsVolatile liquids
Wash waterWaste water
F l u i d sP
um
ps
C
ircul
ator
pum
ps /
hot w
ater
ser
vice
pum
ps, fi
xed
spee
d
Rio
C
Ri
o / R
io Z
Riot
herm
C
Ri
othe
rm
Circ
ulat
or p
umps
, var
iabl
e sp
eed
Riot
roni
c P
/ Rio
tron
ic E
co
Ri
o-Ec
o
Ri
o-Ec
o B
Rio-
Eco
Z
In-li
ne p
umps
with
fixe
d / v
aria
ble
spee
d dr
ive
Etal
ine
/ Eta
line
Z
Et
alin
e Pu
mpD
rive
/ Eta
line
Z Pu
mpD
rive
Etal
ine-
R
Stan
dard
ized
/ cl
ose-
coup
led
pum
ps, fi
xed
/ var
iabl
e sp
eed
Etan
orm
/ Et
anor
m-R
/ Et
anor
m P
umpD
rive
Etab
loc
/ Eta
bloc
Pum
pDriv
e
Et
achr
om B
C / E
tach
rom
BC
Pum
pDriv
e
Et
achr
om N
C / E
tach
rom
NC
Pum
pDriv
e
Et
anor
m G
PV /
CPV
Ho
t wat
er p
umps
HPK-
L
HP
H
HP
K
Hot w
ater
/ th
erm
al o
il pu
mps
Et
anor
m S
YT /
RSY
Etab
loc
SYT
/ Eta
line
SYT
Th
erm
al o
il pu
mps
with
mag
netic
driv
e / c
anne
d m
otor
Etam
agno
SY
/ SYI
/ Bl
oc S
Y
HX
(Nik
kiso
-KSB
)
HY
(Nik
kiso
-KSB
)
Stan
dard
ized
che
mic
al p
umps
CPKN
/ CP
KN P
umpD
rive
CPK-
D
Seal
-less
pum
ps
M
agno
chem
/ M
agno
chem
-Blo
c
Et
asec
o / E
tase
co-I
Etas
eco
RVP
Seco
chem
Ex
Seco
chem
Ex
K
HN
/ BN
/ TN
(Nik
kiso
-KSB
)
HT
/ B
T / T
T (N
ikki
so-K
SB)
HK (N
ikki
so-K
SB)
VN (N
ikki
so-K
SB)
DN (N
ikki
so-K
SB)
Pr
oces
s pu
mps
RPH
CTN
API s
erie
s (N
ikki
so-K
SB)
Ce
ntrif
ugal
pum
p fo
r min
imal
vol
ume
flow
s
M
icro
chem
Ra
inw
ater
har
vest
ing
syst
ems
Hya-
Rain
/ Hy
a-Ra
in N
Hya-
Rain
Eco
Do
mes
tic w
ater
sup
ply
syst
ems
with
aut
omat
ic c
ontr
ol u
nit /
sw
imm
ing
pool
s
M
ulti
Eco
/ Mul
ti Ec
o-Pr
o
M
ulti
Eco-
Top
Mov
itec V
ME
Ixo
Filtr
a N
Pr
essu
re b
oost
er s
yste
ms
Hya-
Solo
E
Hya-
Solo
D /
DV
Hy
a-Ec
o K
/ Hya
-Eco
VP
Hyam
at K
Hyam
at V
Hyam
at V
P
Hy
amat
IK, I
V, IV
P
Drai
nage
pum
ps /
was
te w
ater
pum
ps
Am
a-Dr
aine
r N 3
01, 3
02, 3
03, 3
58
Am
a-Dr
aine
r 400
/10
400/
35 5
00/1
0/11
Ama-
Drai
ner 8
0, 1
00
Am
a-Po
rter
F /
S / I
CS
Ro
tex
MK
/ MKY
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
9
Activated sludgeAggressive liquidsBrackish waterBrineCleaning agentsCondensateCoolantCooling waterCorrosive liquidsDestillateDigested sludgeDipping paintsDrinking waterExplosive liquidsFeed waterFire-fighting waterFlammable liquidsFuelsGas-containing liquidsHarmful liquidsHeating waterHighly aggressive liquidsHigh-temperature hot waterHot waterHygienic liquidsIndustrial service waterInorganic liquidsLiquefied gasLubricantsOilsOrganic liquidsPolymerizing liquidsRaw sludgeRiver, lake and ground waterSeawaterService waterSewage with faecesSewage without faecesSlurriesSlurries (ore, sand, gravel, ash)SolventsSwimming-pool waterThermal oilToxic liquidsValuable liquidsVolatile liquidsWash waterWaste water
C
ircul
ator
pum
ps /
hot w
ater
ser
vice
pum
ps, fi
xed
spee
d
Rio
C
Ri
o / R
io Z
Riot
herm
C
Ri
othe
rm
Circ
ulat
or p
umps
, var
iabl
e sp
eed
Riot
roni
c P
/ Rio
tron
ic E
co
Ri
o-Ec
o
Ri
o-Ec
o B
Rio-
Eco
Z
In-li
ne p
umps
with
fixe
d / v
aria
ble
spee
d dr
ive
Etal
ine
/ Eta
line
Z
Et
alin
e Pu
mpD
rive
/ Eta
line
Z Pu
mpD
rive
Etal
ine-
R
Stan
dard
ized
/ cl
ose-
coup
led
pum
ps, fi
xed
/ var
iabl
e sp
eed
Etan
orm
/ Et
anor
m-R
/ Et
anor
m P
umpD
rive
Etab
loc
/ Eta
bloc
Pum
pDriv
e
Et
achr
om B
C / E
tach
rom
BC
Pum
pDriv
e
Et
achr
om N
C / E
tach
rom
NC
Pum
pDriv
e
Et
anor
m G
PV /
CPV
Ho
t wat
er p
umps
HPK-
L
HP
H
HP
K
Hot w
ater
/ th
erm
al o
il pu
mps
Et
anor
m S
YT /
RSY
Etab
loc
SYT
/ Eta
line
SYT
Th
erm
al o
il pu
mps
with
mag
netic
driv
e / c
anne
d m
otor
Etam
agno
SY
/ SYI
/ Bl
oc S
Y
HX
(Nik
kiso
-KSB
)
HY
(Nik
kiso
-KSB
)
Stan
dard
ized
che
mic
al p
umps
CPKN
/ CP
KN P
umpD
rive
CPK-
D
Seal
-less
pum
ps
M
agno
chem
/ M
agno
chem
-Blo
c
Et
asec
o / E
tase
co-I
Etas
eco
RVP
Seco
chem
Ex
Seco
chem
Ex
K
HN
/ BN
/ TN
(Nik
kiso
-KSB
)
HT
/ B
T / T
T (N
ikki
so-K
SB)
HK (N
ikki
so-K
SB)
VN (N
ikki
so-K
SB)
DN (N
ikki
so-K
SB)
Pr
oces
s pu
mps
RPH
CTN
API s
erie
s (N
ikki
so-K
SB)
Ce
ntrif
ugal
pum
p fo
r min
imal
vol
ume
flow
s
M
icro
chem
Ra
inw
ater
har
vest
ing
syst
ems
Hya-
Rain
/ Hy
a-Ra
in N
Hya-
Rain
Eco
Do
mes
tic w
ater
sup
ply
syst
ems
with
aut
omat
ic c
ontr
ol u
nit /
sw
imm
ing
pool
s
M
ulti
Eco
/ Mul
ti Ec
o-Pr
o
M
ulti
Eco-
Top
Mov
itec V
ME
Ixo
Filtr
a N
Pr
essu
re b
oost
er s
yste
ms
Hya-
Solo
E
Hya-
Solo
D /
DV
Hy
a-Ec
o K
/ Hya
-Eco
VP
Hyam
at K
Hyam
at V
Hyam
at V
P
Hy
amat
IK, I
V, IV
P
Drai
nage
pum
ps /
was
te w
ater
pum
ps
Am
a-Dr
aine
r N 3
01, 3
02, 3
03, 3
58
Am
a-Dr
aine
r 400
/10
400/
35 5
00/1
0/11
Ama-
Drai
ner 8
0, 1
00
Am
a-Po
rter
F /
S / I
CS
Ro
tex
MK
/ MKY
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n n
n
n
n
n
n
n
n
n
n n
n
n
n
n
n
n
n
nn
n
n
n
n
n
n
n
n
n
n
n n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n n
n
n
n
n
n
n
n
n
10
Activated sludgeAggressive liquids
Brackish waterBrine
Cleaning agentsCondensate
CoolantCooling water
Corrosive liquidsDestillate
Digested sludgeDipping paintsDrinking water
Explosive liquidsFeed water
Fire-fighting waterFlammable liquids
FuelsGas-containing liquids
Harmful liquidsHeating water
Highly aggressive liquidsHigh-temperature hot water
Hot waterHygienic liquids
Industrial service waterInorganic liquids
Liquefied gasLubricants
OilsOrganic liquids
Polymerizing liquidsRaw sludge
River, lake and ground waterSeawater
Service waterSewage with faeces
Sewage without faecesSlurries
Slurries (ore, sand, gravel, ash)Solvents
Swimming-pool waterThermal oil
Toxic liquidsValuable liquidsVolatile liquids
Wash waterWaste water
F l u i d s P
um
ps
Li
fting
uni
ts /
colle
ctin
g ta
nks
Ama-
Drai
ner-B
ox
m
ini-C
ompa
cta
Com
pact
a
Pu
mpi
ng S
tatio
n CK
800
-Eu
Ama-
Port
er C
K Pu
mpi
ng S
tatio
n
Am
arex
N C
K Pu
mpi
ng S
tatio
n
Ev
amat
ic-B
ox /
Evam
atic
-Box
ICS
Su
bmer
sibl
e m
otor
pum
ps
Am
arex
N
Am
arex
KRT
Amar
ex K
RT d
ry-in
stal
led
Amar
ex K
RT w
et/d
ry-in
stal
led
Su
bmer
sibl
e pu
mps
in d
isch
arge
tube
s
Am
acan
K
Am
acan
P
Am
acan
S
Mix
ers
/ agi
tato
rs /
tank
cle
anin
g un
its
Am
amix
Amap
rop
Amaj
et
Am
alin
e
Pum
ps fo
r sol
ids-
lade
n flu
ids
Sew
atec
/ Se
wab
loc
KWP
/ KW
P-Bl
oc
Slur
ry p
umps
WBC
LSA-
S
LC
C-M
/ LC
C-R
TBC
LSR
LCV
FGD
Meg
a
HH
D
M
HD
LH
D
M
DX
ZW
Se
lf-pr
imin
g pu
mps
Etap
rime
L
Et
aprim
e B
/ BN
Su
bmer
sibl
e bo
reho
le p
umps
S
100D
/ U
PA 1
00C
UPA
150
C
U
PA 2
00, 2
00B,
250
C
U
PA 3
00, 3
50
U
PZ, B
SX-B
SF
High
-pre
ssur
e pu
mps
, fixe
d / v
aria
ble
spee
d
M
ovite
c V /
LHS
/ VS
/ VC
Mov
itec
Pum
pDriv
e
M
ultit
ec /
Mul
titec
Pum
pDriv
e
Axia
lly s
plit
pum
ps
O
meg
a
RD
LO
Hygi
enic
pum
ps fo
r the
food
, bev
erag
e an
d ph
arm
aceu
tical
indu
strie
s
Vi
tach
rom
/ Vi
taca
st /
Vita
cast
E
Vi
tapr
ime
/ Vita
stag
e / V
italo
be
Pum
ps fo
r pow
er s
tatio
n co
nven
tiona
l isl
ands
CH
TA /
CHTC
/ CH
TD
CH
TR
HG
B / H
GC
/ HG
D
HG
M
YN
K / K
RHA
RHD
LUV
/ LU
VA
WKT
/ W
KTA
/ WKT
B
SE
Z / S
EZT
/ PHZ
/ PN
Z
SN
W /
PNW
SPY
Pu
mps
for p
ower
sta
tion
nucl
ear i
slan
ds
RE
R / R
SR /
PSR
LUV
nucl
ear
RHM
RVM
RHR
/ RVR
RUV
Pu
mps
for s
eaw
ater
des
alin
atio
n by
reve
rse
osm
osis
RP
H-RO
HGM
-RO
Mul
titec
-RO
M
onito
ring
and
diag
nost
ic s
yste
ms
Pum
pMet
er
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n n
11
Activated sludgeAggressive liquidsBrackish waterBrineCleaning agentsCondensateCoolantCooling waterCorrosive liquidsDestillateDigested sludgeDipping paintsDrinking waterExplosive liquidsFeed waterFire-fighting waterFlammable liquidsFuelsGas-containing liquidsHarmful liquidsHeating waterHighly aggressive liquidsHigh-temperature hot waterHot waterHygienic liquidsIndustrial service waterInorganic liquidsLiquefied gasLubricantsOilsOrganic liquidsPolymerizing liquidsRaw sludgeRiver, lake and ground waterSeawaterService waterSewage with faecesSewage without faecesSlurriesSlurries (ore, sand, gravel, ash)SolventsSwimming-pool waterThermal oilToxic liquidsValuable liquidsVolatile liquidsWash waterWaste water
Li
fting
uni
ts /
colle
ctin
g ta
nks
Ama-
Drai
ner-B
ox
m
ini-C
ompa
cta
Com
pact
a
Pu
mpi
ng S
tatio
n CK
800
-Eu
Ama-
Port
er C
K Pu
mpi
ng S
tatio
n
Am
arex
N C
K Pu
mpi
ng S
tatio
n
Ev
amat
ic-B
ox /
Evam
atic
-Box
ICS
Su
bmer
sibl
e m
otor
pum
ps
Am
arex
N
Am
arex
KRT
Amar
ex K
RT d
ry-in
stal
led
Amar
ex K
RT w
et/d
ry-in
stal
led
Su
bmer
sibl
e pu
mps
in d
isch
arge
tube
s
Am
acan
K
Am
acan
P
Am
acan
S
Mix
ers
/ agi
tato
rs /
tank
cle
anin
g un
its
Am
amix
Amap
rop
Amaj
et
Am
alin
e
Pum
ps fo
r sol
ids-
lade
n flu
ids
Sew
atec
/ Se
wab
loc
KWP
/ KW
P-Bl
oc
Slur
ry p
umps
WBC
LSA-
S
LC
C-M
/ LC
C-R
TBC
LSR
LCV
FGD
Meg
a
HH
D
M
HD
LH
D
M
DX
ZW
Se
lf-pr
imin
g pu
mps
Etap
rime
L
Et
aprim
e B
/ BN
Su
bmer
sibl
e bo
reho
le p
umps
S
100D
/ U
PA 1
00C
UPA
150
C
U
PA 2
00, 2
00B,
250
C
U
PA 3
00, 3
50
U
PZ, B
SX-B
SF
High
-pre
ssur
e pu
mps
, fixe
d / v
aria
ble
spee
d
M
ovite
c V /
LHS
/ VS
/ VC
Mov
itec
Pum
pDriv
e
M
ultit
ec /
Mul
titec
Pum
pDriv
e
Axia
lly s
plit
pum
ps
O
meg
a
RD
LO
Hygi
enic
pum
ps fo
r the
food
, bev
erag
e an
d ph
arm
aceu
tical
indu
strie
s
Vi
tach
rom
/ Vi
taca
st /
Vita
cast
E
Vi
tapr
ime
/ Vita
stag
e / V
italo
be
Pum
ps fo
r pow
er s
tatio
n co
nven
tiona
l isl
ands
CH
TA /
CHTC
/ CH
TD
CH
TR
HG
B / H
GC
/ HG
D
HG
M
YN
K / K
RHA
RHD
LUV
/ LU
VA
WKT
/ W
KTA
/ WKT
B
SE
Z / S
EZT
/ PHZ
/ PN
Z
SN
W /
PNW
SPY
Pu
mps
for p
ower
sta
tion
nucl
ear i
slan
ds
RE
R / R
SR /
PSR
LUV
nucl
ear
RHM
RVM
RHR
/ RVR
RUV
Pu
mps
for s
eaw
ater
des
alin
atio
n by
reve
rse
osm
osis
RP
H-RO
HGM
-RO
Mul
titec
-RO
M
onito
ring
and
diag
nost
ic s
yste
ms
Pum
pMet
er
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n n n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
12
Air-conditioning systemsAquaculture
Boiler circulationBoiler feed applications
Chemical industryCleaning of stormwater tanks / storage sewers
Condensate transportCooling circuitsDescaling units
DewateringDisposal
District heatingDock facilities
Domestic water supplyDrainage
Drainage of pits, shafts, etc.Dredging
Fire-fighting systemsFlue gas desulphurization
Food and beverages industryFountains
Heat recovery systemsHeavy oil and coal upgrading
HomogenizationHot water heating systemsHydraulic solids transport
Industrial recirculation systemsIrrigation
Keeping in suspensionLowering ground water levels
Maintaining ground water levelsMiningMixing
Nuclear power stationsPaint shops
Paper and cellulose industryPetrochemical industry
Pharmaceutical industry Pipelines and tank farms
Pressure boostingProcess engineering
Rainwater harvestingRecirculation
RefineriesSeawater desalination / reverse osmosis
Sewage treatment plantsShipbuilding
Sludge disposalSludge processing
Snow gunsSpray irrigationSugar industry
Swimming poolsThickening
Washing plantsWater extraction
Water supplyWater treatment systems
A p p l i c a t i o n sP
um
ps
C
ircul
ator
pum
ps /
hot w
ater
ser
vice
pum
ps, fi
xed
spee
d
Rio
C
Ri
o / R
io Z
Riot
herm
C
Ri
othe
rm
Circ
ulat
or p
umps
, var
iabl
e sp
eed
Riot
roni
c P
/ Rio
tron
ic E
co
Ri
o-Ec
o
Ri
o-Ec
o B
Rio-
Eco
Z
In-li
ne p
umps
with
fixe
d / v
aria
ble
spee
d dr
ive
Etal
ine
/ Eta
line
Z
Et
alin
e Pu
mpD
rive
/ Eta
line
Z Pu
mpD
rive
Etal
ine-
R
Stan
dard
ized
/ cl
ose-
coup
led
pum
ps, fi
xed
/ var
iabl
e sp
eed
Etan
orm
/ Et
anor
m-R
/ Et
anor
m P
umpD
rive
Etab
loc
/ Eta
bloc
Pum
pDriv
e
Et
achr
om B
C / E
tach
rom
BC
Pum
pDriv
e
Et
achr
om N
C / E
tach
rom
NC
Pum
pDriv
e
Et
anor
m G
PV /
CPV
Ho
t wat
er p
umps
HPK-
L
HP
H
HP
K
Hot w
ater
/ th
erm
al o
il pu
mps
Et
anor
m S
YT /
RSY
Etab
loc
SYT
/ Eta
line
SYT
Th
erm
al o
il pu
mps
with
mag
netic
driv
e / c
anne
d m
otor
Etam
agno
SY
/ SYI
/ Bl
oc S
Y
HX
(Nik
kiso
-KSB
)
HY
(Nik
kiso
-KSB
)
Stan
dard
ized
che
mic
al p
umps
CPKN
/ CP
KN P
umpD
rive
CPK-
D
Se
al-le
ss p
umps
Mag
noch
em /
Mag
noch
em-B
loc
Etas
eco
/ Eta
seco
-I
Et
asec
o RV
P
Se
coch
em E
x
Se
coch
em E
x K
HN /
BN /
TN (N
ikki
so-K
SB)
HT /
BT
/ TT
(Nik
kiso
-KSB
)
HK
(Nik
kiso
-KSB
)
VN
(Nik
kiso
-KSB
)
DN
(Nik
kiso
-KSB
)
Proc
ess
pum
ps
RP
H
CT
N
AP
I ser
ies
(Nik
kiso
-KSB
)
Cent
rifug
al p
ump
for m
inim
al v
olum
e flo
ws
Mic
roch
em
Rain
wat
er h
arve
stin
g sy
stem
s
Hy
a-Ra
in /
Hya-
Rain
N
Hy
a-Ra
in E
co
Dom
estic
wat
er s
uppl
y sy
stem
s w
ith a
utom
atic
con
trol
uni
t / s
wim
min
g po
ols
Mul
ti Ec
o / M
ulti
Eco-
Pro
Mul
ti Ec
o-To
p
M
ovite
c VM
E
Ix
o
Fi
ltra
N
Pres
sure
boo
ster
sys
tem
s
Hy
a-So
lo E
Hy
a-So
lo D
/ DV
Hya-
Eco
K / H
ya-E
co V
P
Hy
amat
K
Hy
amat
V
Hy
amat
VP
Hyam
at IK
, IV,
IVP
Dr
aina
ge p
umps
/ w
aste
wat
er p
umps
Ama-
Drai
ner N
301
, 302
, 303
, 358
Ama-
Drai
ner 4
00/1
0 40
0/35
500
/10/
11
Am
a-Dr
aine
r 80,
100
Ama-
Port
er F
/ S
/ ICS
Rote
x
M
K / M
KY
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
13
Air-conditioning systemsAquacultureBoiler circulationBoiler feed applicationsChemical industryCleaning of stormwater tanks / storage sewersCondensate transportCooling circuitsDescaling unitsDewateringDisposalDistrict heatingDock facilitiesDomestic water supplyDrainageDrainage of pits, shafts, etc.DredgingFire-fighting systemsFlue gas desulphurizationFood and beverages industryFountainsHeat recovery systemsHeavy oil and coal upgradingHomogenizationHot water heating systemsHydraulic solids transportIndustrial recirculation systemsIrrigationKeeping in suspensionLowering ground water levelsMaintaining ground water levelsMiningMixingNuclear power stationsPaint shopsPaper and cellulose industryPetrochemical industryPharmaceutical industryPipelines and tank farmsPressure boostingProcess engineeringRainwater harvestingRecirculationRefineriesSeawater desalination / reverse osmosisSewage treatment plantsShipbuildingSludge disposalSludge processingSnow gunsSpray irrigationSugar industrySwimming poolsThickeningWashing plantsWater extractionWater supplyWater treatment systems
C
ircul
ator
pum
ps /
hot w
ater
ser
vice
pum
ps, fi
xed
spee
d
Rio
C
Ri
o / R
io Z
Riot
herm
C
Ri
othe
rm
Circ
ulat
or p
umps
, var
iabl
e sp
eed
Riot
roni
c P
/ Rio
tron
ic E
co
Ri
o-Ec
o
Ri
o-Ec
o B
Rio-
Eco
Z
In-li
ne p
umps
with
fixe
d / v
aria
ble
spee
d dr
ive
Etal
ine
/ Eta
line
Z
Et
alin
e Pu
mpD
rive
/ Eta
line
Z Pu
mpD
rive
Etal
ine-
R
Stan
dard
ized
/ cl
ose-
coup
led
pum
ps, fi
xed
/ var
iabl
e sp
eed
Etan
orm
/ Et
anor
m-R
/ Et
anor
m P
umpD
rive
Etab
loc
/ Eta
bloc
Pum
pDriv
e
Et
achr
om B
C / E
tach
rom
BC
Pum
pDriv
e
Et
achr
om N
C / E
tach
rom
NC
Pum
pDriv
e
Et
anor
m G
PV /
CPV
Ho
t wat
er p
umps
HPK-
L
HP
H
HP
K
Hot w
ater
/ th
erm
al o
il pu
mps
Et
anor
m S
YT /
RSY
Etab
loc
SYT
/ Eta
line
SYT
Th
erm
al o
il pu
mps
with
mag
netic
driv
e / c
anne
d m
otor
Etam
agno
SY
/ SYI
/ Bl
oc S
Y
HX
(Nik
kiso
-KSB
)
HY
(Nik
kiso
-KSB
)
Stan
dard
ized
che
mic
al p
umps
CPKN
/ CP
KN P
umpD
rive
CPK-
D
Se
al-le
ss p
umps
Mag
noch
em /
Mag
noch
em-B
loc
Etas
eco
/ Eta
seco
-I
Et
asec
o RV
P
Se
coch
em E
x
Se
coch
em E
x K
HN /
BN /
TN (N
ikki
so-K
SB)
HT /
BT
/ TT
(Nik
kiso
-KSB
)
HK
(Nik
kiso
-KSB
)
VN
(Nik
kiso
-KSB
)
DN
(Nik
kiso
-KSB
)
Proc
ess
pum
ps
RP
H
CT
N
AP
I ser
ies
(Nik
kiso
-KSB
)
Cent
rifug
al p
ump
for m
inim
al v
olum
e flo
ws
Mic
roch
em
Rain
wat
er h
arve
stin
g sy
stem
s
Hy
a-Ra
in /
Hya-
Rain
N
Hy
a-Ra
in E
co
Dom
estic
wat
er s
uppl
y sy
stem
s w
ith a
utom
atic
con
trol
uni
t / s
wim
min
g po
ols
Mul
ti Ec
o / M
ulti
Eco-
Pro
Mul
ti Ec
o-To
p
M
ovite
c VM
E
Ix
o
Fi
ltra
N
Pres
sure
boo
ster
sys
tem
s
Hy
a-So
lo E
Hy
a-So
lo D
/ DV
Hya-
Eco
K / H
ya-E
co V
P
Hy
amat
K
Hy
amat
V
Hy
amat
VP
Hyam
at IK
, IV,
IVP
Dr
aina
ge p
umps
/ w
aste
wat
er p
umps
Ama-
Drai
ner N
301
, 302
, 303
, 358
Ama-
Drai
ner 4
00/1
0 40
0/35
500
/10/
11
Am
a-Dr
aine
r 80,
100
Ama-
Port
er F
/ S
/ ICS
Rote
x
M
K / M
KY
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
14
Air-conditioning systemsAquaculture
Boiler circulationBoiler feed applications
Chemical industryCleaning of stormwater tanks / storage sewers
Condensate transportCooling circuitsDescaling units
DewateringDisposal
District heatingDock facilities
Domestic water supplyDrainage
Drainage of pits, shafts, etc.Dredging
Fire-fighting systemsFlue gas desulphurization
Food and beverages industryFountains
Heat recovery systemsHeavy oil and coal upgrading
HomogenizationHot water heating systemsHydraulic solids transport
Industrial recirculation systemsIrrigation
Keeping in suspensionLowering ground water levels
Maintaining ground water levelsMiningMixing
Nuclear power stationsPaint shops
Paper and cellulose industryPetrochemical industry
Pharmaceutical industryPipelines and tank farms
Pressure boostingProcess engineering
Rainwater harvestingRecirculation
RefineriesSeawater desalination / reverse osmosis
Sewage treatment plantsShipbuilding
Sludge disposalSludge processing
Snow gunsSpray irrigationSugar industry
Swimming poolsThickening
Washing plantsWater extraction
Water supplyWater treatment systems
Pu
mp
sA p p l i c a t i o n s
Li
fting
uni
ts /
colle
ctin
g ta
nks
Ama-
Drai
ner-B
ox
m
ini-C
ompa
cta
Com
pact
a
Pu
mpi
ng S
tatio
n CK
800
-Eu
Ama-
Port
er C
K Pu
mpi
ng S
tatio
n
Am
arex
N C
K Pu
mpi
ng S
tatio
n
Ev
amat
ic-B
ox /
Evam
atic
-Box
ICS
Su
bmer
sibl
e m
otor
pum
ps
Am
arex
N
Am
arex
KRT
Amar
ex K
RT d
ry-in
stal
led
Amar
ex K
RT w
et/d
ry-in
stal
led
Su
bmer
sibl
e pu
mps
in d
isch
arge
tube
s
Am
acan
K
Am
acan
P
Am
acan
S
Mix
ers
/ agi
tato
rs /
tank
cle
anin
g un
its
Am
amix
Amap
rop
Amaj
et
Am
alin
e
Pum
ps fo
r sol
ids-
lade
n flu
ids
Sew
atec
/ Se
wab
loc
KWP
/ KW
P-Bl
oc
Slur
ry p
umps
WBC
LSA-
S
LC
C-M
/ LC
C-R
TBC
LSR
LCV
FGD
Meg
a
HH
D
M
HD
LH
D
M
DX
ZW
Se
lf-pr
imin
g pu
mps
Etap
rime
L
Et
aprim
e B
/ BN
Su
bmer
sibl
e bo
reho
le p
umps
S
100D
/ U
PA 1
00C
UPA
150
C
U
PA 2
00, 2
00B,
250
C
U
PA 3
00, 3
50
U
PZ, B
SX-B
SF
High
-pre
ssur
e pu
mps
, fixe
d / v
aria
ble
spee
d
M
ovite
c V /
LHS
/ VS
/ VC
Mov
itec
Pum
pDriv
e
M
ultit
ec /
Mul
titec
Pum
pDriv
e
Axia
lly s
plit
pum
ps
O
meg
a
RD
LO
Hygi
enic
pum
ps fo
r the
food
, bev
erag
e an
d ph
arm
aceu
tical
indu
strie
s
Vi
tach
rom
/ Vi
taca
st /
Vita
cast
E
Vi
tapr
ime
/ Vita
stag
e / V
italo
be
Pum
ps fo
r pow
er s
tatio
n co
nven
tiona
l isl
ands
CH
TA /
CHTC
/ CH
TD
CH
TR
HG
B / H
GC
/ HG
D
HG
M
YN
K / K
RHA
RHD
LUV
/ LU
VA
WKT
/ W
KTA
/ WKT
B
SE
Z / S
EZT
/ PHZ
/ PN
Z
SN
W /
PNW
SPY
Pu
mps
for p
ower
sta
tion
nucl
ear i
slan
ds
RE
R / R
SR /
PSR
LUV
nucl
ear
RHM
RVM
RHR
/ RVR
RUV
Pu
mps
for s
eaw
ater
des
alin
atio
n by
reve
rse
osm
osis
RP
H-RO
HGM
-RO
Mul
titec
-RO
n
n n n n n n n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
15
Air-conditioning systemsAquacultureBoiler circulationBoiler feed applicationsChemical industryCleaning of stormwater tanks / storage sewersCondensate transportCooling circuitsDescaling unitsDewateringDisposalDistrict heatingDock facilitiesDomestic water supplyDrainageDrainage of pits, shafts, etc.DredgingFire-fighting systemsFlue gas desulphurizationFood and beverages industryFountainsHeat recovery systemsHeavy oil and coal upgradingHomogenizationHot water heating systemsHydraulic solids transportIndustrial recirculation systemsIrrigationKeeping in suspensionLowering ground water levelsMaintaining ground water levelsMiningMixingNuclear power stationsPaint shopsPaper and cellulose industryPetrochemical industryPharmaceutical industryPipelines and tank farmsPressure boostingProcess engineeringRainwater harvestingRecirculationRefineriesSeawater desalination / reverse osmosisSewage treatment plantsShipbuildingSludge disposalSludge processingSnow gunsSpray irrigationSugar industrySwimming poolsThickeningWashing plantsWater extractionWater supplyWater treatment systems
Li
fting
uni
ts /
colle
ctin
g ta
nks
Ama-
Drai
ner-B
ox
m
ini-C
ompa
cta
Com
pact
a
Pu
mpi
ng S
tatio
n CK
800
-Eu
Ama-
Port
er C
K Pu
mpi
ng S
tatio
n
Am
arex
N C
K Pu
mpi
ng S
tatio
n
Ev
amat
ic-B
ox /
Evam
atic
-Box
ICS
Su
bmer
sibl
e m
otor
pum
ps
Am
arex
N
Am
arex
KRT
Amar
ex K
RT d
ry-in
stal
led
Amar
ex K
RT w
et/d
ry-in
stal
led
Su
bmer
sibl
e pu
mps
in d
isch
arge
tube
s
Am
acan
K
Am
acan
P
Am
acan
S
Mix
ers
/ agi
tato
rs /
tank
cle
anin
g un
its
Am
amix
Amap
rop
Amaj
et
Am
alin
e
Pum
ps fo
r sol
ids-
lade
n flu
ids
Sew
atec
/ Se
wab
loc
KWP
/ KW
P-Bl
oc
Slur
ry p
umps
WBC
LSA-
S
LC
C-M
/ LC
C-R
TBC
LSR
LCV
FGD
Meg
a
HH
D
M
HD
LH
D
M
DX
ZW
Se
lf-pr
imin
g pu
mps
Etap
rime
L
Et
aprim
e B
/ BN
Su
bmer
sibl
e bo
reho
le p
umps
S
100D
/ U
PA 1
00C
UPA
150
C
U
PA 2
00, 2
00B,
250
C
U
PA 3
00, 3
50
U
PZ, B
SX-B
SF
High
-pre
ssur
e pu
mps
, fixe
d / v
aria
ble
spee
d
M
ovite
c V /
LHS
/ VS
/ VC
Mov
itec
Pum
pDriv
e
M
ultit
ec /
Mul
titec
Pum
pDriv
e
Axia
lly s
plit
pum
ps
O
meg
a
RD
LO
Hygi
enic
pum
ps fo
r the
food
, bev
erag
e an
d ph
arm
aceu
tical
indu
strie
s
Vi
tach
rom
/ Vi
taca
st /
Vita
cast
E
Vi
tapr
ime
/ Vita
stag
e / V
italo
be
Pum
ps fo
r pow
er s
tatio
n co
nven
tiona
l isl
ands
CH
TA /
CHTC
/ CH
TD
CH
TR
HG
B / H
GC
/ HG
D
HG
M
YN
K / K
RHA
RHD
LUV
/ LU
VA
WKT
/ W
KTA
/ WKT
B
SE
Z / S
EZT
/ PHZ
/ PN
Z
SN
W /
PNW
SPY
Pu
mps
for p
ower
sta
tion
nucl
ear i
slan
ds
RE
R / R
SR /
PSR
LUV
nucl
ear
RHM
RVM
RHR
/ RVR
RUV
Pu
mps
for s
eaw
ater
des
alin
atio
n by
reve
rse
osm
osis
RP
H-RO
HGM
-RO
Mul
titec
-RO
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n n
n
n
n
n
n
n n
n n n
n
16
Design: Maintenance-free, glandless wet rotor pump, screw-ended, with three speed levels.
Applications: Industrial recirculation systems, air-conditioning systems, cooling circuits, heat recovery systems and hot water heating systems.
Rio C
Rp _______________ 1 -11/4
Q [m3/h] _________ max. 4H [m] __________ max. 5.8p [bar] __________ max. 10T [°C] _______ -10 to +110Data for 50 Hz operation
Reference no. 1120.5-10 also available in 60 HzSwitchgears
Circulator pump with manual speed control
C i r c u l a t o r p u m p s / h o t w a t e r s e r v i c e p u m p s , f i x e d s p e e d
Design: Maintenance-free, glandless wet rotor pump, flanged or screw-ended, with three speed levels.
Applications: Industrial recirculation systems, air-conditioning systems, cooling circuits, heat recovery systems and hot water heating systems.
Rio
Rp / DN __ 1-11/4 / 40 - 100Q [m3/h] ________ max. 77H [m] ___________ max. 19p [bar] __________ max. 10T [°C] _______ -20 to +130Data for 50 Hz operation
Switchgears
Circulator pump with manual speed control
Reference no. 1115.51-10 also available in 60 Hz
Design: Maintenance-free, glandless wet rotor pump, flanged or screw-ended, with three speed levels.
Applications: Air-conditioning systems, cooling circuits and water supply.
Riotherm C
Rp / DN __ 1/2 -11/4 / 40 - 50Q [m3/h] ________ max. 28H [m] __________ max. 7.5p [bar] __________ max. 10T [°C] _______ -10 to +110Data for 50 Hz operation
Reference no. 1109.5-10 also suitable for 60 Hz operation
Hot water service pump
Design: Screw-ended dry rotor pump with mechanical seal and fixed speed.
Applications: Hot water supply systems, swimming pools, cooling circuits and industrial plants.
Riotherm
Rp _______________ 1-11/4
Q [m3/h] ________ max. 10H [m] ____________ max. 6p [bar] __________ max. 10T [°C] ________ -2 to +110Data for 50 Hz operation
Reference no. 1118.5-10
Hot water service pump
also available in 60 HzSwitchgears
Automation possible
Design: Maintenance-free, glandless wet rotor pump, flanged or screw-ended, with three speed levels; in twin pump design (Rio Z) for standby operation with inte-grated swing check valve or, on option, peak load operation (parallel operation).
Applications: Industrial recirculation systems, air-conditioning systems, cooling circuits, heat recovery systems and hot water heating systems.
Rio Z
Rp / DN ___ 1-11/4 / 32 - 80Q [m3/h] _______ max. 130H [m] ___________ max. 18p [bar] __________ max. 10T [°C] _______ -20 to +130Data for 50 Hz operation
Switchgears
Circulator pump with manual speed control
Reference no. 1115.51-10 also available in 60 Hz
Switchgears
17
C i r c u l a t o r p u m p s , v a r i a b l e s p e e d
Design: Maintenance-free wet rotor pump with integrated frequency inverter for continuously variable differential pressure control and IR interface for remote control.
Applications: Industrial recirculation systems, air-conditioning systems, cooling circuits, heat recovery systems and hot water heating systems.
Rio-Eco
Rp / DN __ 1-11/4 / 32 - 100Q [m3/h] ________ max. 62H [m] ___________ max. 13p [bar] __________ max. 10T [°C] _______ -10 to +110n [min-1] ______ max. 4800
Reference no. 1137.5-10 also suitable for 60 Hz operation
High-efficiency circulator pump with continuously variable differential pressure control
Design: Maintenance-free wet rotor pump with integrated frequency inverter for continuously variable differential pressure control.
Applications: Industrial recirculation systems, air-conditioning systems, heat recovery systems and hot water heating systems.
Riotronic Eco
Rp _______________ 1-11/4
Q [m3/h] _______ max. 2.5H [m] ____________ max. 5p [bar] __________ max. 10T [°C] ______ +15 to +110n [min-1] ______ max. 3500
Reference no. 1112.51-10
High-efficiency circulator pump with continuously variable differential pressure control
BOA-Systronic
BOA-Systronic
Automation possibleFactory-automated
Design: Maintenance-free wet rotor pump with integrated frequency inverter forcontinuously variable differential pressure control.
Applications: Industrial recirculation systems, air-conditioning systems, heat recovery systems and hot water heating systems.
Riotronic P
Rp _______________ 1-11/4
Q [m3/h] _______ max. 4.2H [m] ____________ max. 6p [bar] __________ max. 10T [°C] ________ -2 to +110n [min-1] ______ max. 4230
Reference no. 1112.52-10 also suitable for 60 Hz operation
High-efficiency circulator pump with continuously variable differential pressure control
Design: Maintenance-free wet rotor pump with integrated frequency inverter for continuously variable differential pressure control and IR interface for remote control.
Applications: Air-conditioning systems, cooling circuits and water supply
Rio-Eco B
Rp / DN ___ 1-11/4 / 40 - 65Q [m3/h] ________ max. 38H [m] ___________ max. 10p [bar] __________ max. 10T [°C] ________ -10 to +80n [min-1] ______ max. 4800
Reference no. 1137.5-10 also suitable for 60 Hz operation
High-efficiency circulator pump with continuously variable differential pressure control
BOA-Systronic
Design: Maintenance-free wet rotor pump in twin pump design, with integrated frequency inverter for continuously variable differential pressure control and IR interface for remote control. Optional pump assignment to main or stand-by duty, with automatic changeover in the event of a fault, timer-controlled pump change-over or parallel operation; peak load pump started or stopped as required for optimum efficiency.
Applications: Industrial recirculation systems, air-conditioning systems, cooling circuits, heat recovery systems and hot water heating systems.
Rio-Eco Z
DN _____________ 32 - 80Q [m3/h] _______ max. 108H [m] ___________ max. 13p [bar] __________ max. 10T [°C] _______ -10 to +110n [min-1] ______ max. 4800
Reference no. 1137.51-10 also suitable for 60 Hz operation
High-efficiency circulator pump with continuously variable differential pressure control
BOA-Systronic
18
I n - l i n e p u m p s w i t h f i x e d / v a r i a b l e s p e e d d r i v e
Design: Close-coupled, in-line circulator pump with volute casing and standardized motor.
Applications: Hot water heating systems, cooling circuits, air-conditioning, water and service water supply systems, industrial recirculation systems.
Etaline
DN _____________ 32 - 200Q [m3/h] _______ max. 700H [m] ___________ max. 95p [bar] __________ max. 16T [°C] _______ -30 to +140Data for 50 Hz operation
Reference no. 1146.51-10 also available in 60 HzPumpMeter · Hyamaster · LevelControl · Switchgears
In-line pump
Design: Close-coupled, in-line twin circulator pump, pump shaft and motor shaft are rigidly coupled.
Applications: Hot water heating systems, cooling circuits, air-conditioning systems, water and service water supply systems, industrial recirculation systems.
Etaline Z
DN _____________ 32 - 200Q [m3/h] ______ max. 1120H [m] ___________ max. 77p [bar] __________ max. 16T [°C] _______ -30 to +140Data for 50 Hz operation
Reference no. 1148.5-10 also available in 60 HzPumpMeter · Hyamaster · LevelControl · Switchgears
In-line twin pump
Design: Close-coupled in-line circulator pump with motor-mounted variable speed system; pump shaft and motor shaft are rigidly coupled.
Applications: Hot water heating systems, cooling circuits, air-conditioning systems, water and service water supply systems, industrial recirculation systems.
DN _____________ 32 - 200Q [m3/h] _______ max. 788H [m] __________ max. 100p [bar] __________ max. 16T [°C] _______ -10 to +110n [min-1] ______ max. 4200
Reference no. 1149.52-10 also suitable for 60 Hz operation
In-line pump with motor-mounted variable speed systemEtaline PumpDrive
PumpMeter · BOA-Systronic
Design: Close-coupled in-line circulator pump, in twin pump design with motor-mounted variable speed system; pump shaft and motor shaft are rigidly coupled. Double pump control modules (accessories) enable redundant operation of Etaline Z without a higher-level controller.
Applications: Hot water heating systems, cooling circuits, air-conditioning systems, water and service water supply systems, industrial recirculation systems.
DN _____________ 32 - 200Q [m3/h] _______ max. 990H [m] ___________ max. 76p [bar] __________ max. 16T [°C] _______ -10 to +110n [[min-1] ______ max. 4200
Reference no. 1154.51-10 also suitable for 60 Hz operation
In-line pump with motor-mounted variable speed systemEtaline Z PumpDrive
PumpMeter · BOA-Systronic
Automation possibleFactory-automated
19Automation possibleFactory-automated
I n - l i n e p u m p s w i t h f i x e d / v a r i a b l e s p e e d d r i v e
Design: Vertical close-coupled, in-line circulator pump with volute casing and standardized motor.
Applications: Hot water heating systems, cooling circuits, air-conditioning, water and service water supply systems, industrial recirculation systems.
Etaline-R
DN ___________ 150 - 350Q [m3/h] ______ max. 1900H [m] ___________ max. 93p [bar] __________ max. 25T [°C] _______ -30 to +140Data for 50 Hz operation
Reference no. 1146.51-10 also available in 60 HzPumpMeter · PumpDrive · Hyamaster · Switchgears
In-line pump
S t a n d a r d i z e d / c l o s e - c o u p l e d p u m p s , f i x e d / v a r i a b l e s p e e d
Design: Horizontal, long-coupled, single-stage volute casing pump (pump size 125 - 500 with two stages) with ratings and main dimensions to EN 733, in back pull-out design, with replaceable shaft sleeves / shaft protecting sleeves and casing wear rings. ATEX-compliant version available.
Applications: Spray irrigation, irrigation, drainage, district heating, water supplysystems, heating and air-conditioning systems, condensate transport, swimmingpools, fire-fighting systems, handling of hot water, cooling water, fire-fighting water, oil, brine, drinking water, brackish water, service water, etc.
Etanorm / Etanorm-R
DN _____________ 32 - 300Q [m3/h] ______ max. 1900H [m] __________ max. 102p [bar] __________ max. 16T [°C] ________ max. +140Data for 50 Hz operation
Reference no. 1211.5-10 also available in 60 HzPumpMeter • Hyamaster
Standardized pump
Design: Horizontal, long-coupled, single-stage volute casing pump in back pull-out design, with replaceable shaft sleeves / shaft protecting sleeves and casing wear rings and motor-mounted variable speed system.
Applications: Spray irrigation, irrigation, drainage, district heating, water supply systems, heating and air-conditioning systems, condensate transport, swimming pools, fire-fighting systems, handling of hot water, cooling water, fire-fighting water, oil, brine, drinking water, brackish water, service water, etc.
Etanorm PumpDrive
DN _____________ 32 - 150Q [m3/h] _______ max. 800H [m] __________ max. 102p [bar] __________ max. 16T [°C] ________ max. +140n [min-1] ______ max. 4200
Reference no. 1211.5-10 + 4070.5-10
Standardized pump with motor-mounted variable speed system
Design: Close-coupled, single-stage volute casing pump, ratings to EN 733, withreplaceable shaft sleeve and casing wear rings. ATEX-compliant version available.
Applications: Spray irrigation, irrigation, drainage and water supply systems, heating and air-conditioning systems, condensate transport, swimming pools, handling of hot water, cooling water, fire-fighting water, seawater, oil, brine, drinking water, cleaning agents, brackish water, service water, etc.
Etabloc
DN _____________ 25 - 150Q [m3/h] _______ max. 660H [m] __________ max. 102p [bar] __________ max. 16T [°C] ________ max. +140Data for 50 Hz operation
Reference no. 1167.5-10 also available in 60 HzPumpMeter • Hyamaster
Close-coupled pump
PumpMeter
20 Automation possibleFactory-automated
Design: Close-coupled, single-stage volute casing pump, ratings to EN 733, withreplaceable shaft sleeve and casing wear rings and motor-mounted variable speed system.
Applications: Spray irrigation, irrigation, drainage and water supply systems, heat-ing and air-conditioning systems, condensate transport, swimming pools, handling of hot water, cooling water, fire-fighting water, seawater, oil, brine, drinking water, cleaning agents, brackish water, service water, etc.
Etabloc PumpDrive
DN _____________ 25 - 150Q [m3/h] _______ max. 800H [m] __________ max. 102p [bar] __________ max. 16T [°C] ________ max. +110n [min-1] ______ max. 4200
Reference no. 1167.5-10 + 4070.5-10
Close-coupled pump with motor-mounted variable speed system
Design: Close-coupled, horizontal, single-stage annular casing pump, with ratings and main dimensions to EN 733, with replaceable casing wear rings. ATEX-compliant version available.
Applications: Spray irrigation, irrigation, drainage and water supply systems, heating and air-conditioning systems, fire-fighting systems, condensate transport, swimming pools, handling of hot water, cooling water, fire-fighting water, oil, drinking water, cleaning agents, service water.
Etachrom BC
DN ______________ 25 - 80Q [m3/h] _______ max. 260H [m] __________ max. 108p [bar] __________ max. 12T [°C] ________ max. +110Data for 50 Hz operation
Reference no. 1213.5-10 also available in 60 HzPumpMeter · Hyamaster
Close-coupled chrome steel pump
S t a n d a r d i z e d / c l o s e - c o u p l e d p u m p s , f i x e d / v a r i a b l e s p e e d
PumpMeter
Design: Close-coupled, horizontal, single-stage annular casing pump, with ratings and main dimensions to EN 733, with replaceable casing wear rings and motor-mounted variable speed system.
Applications: Spray irrigation, irrigation, drainage and water supply systems, heating and air-conditioning systems, fire-fighting systems, condensate transport, swimming pools, handling of hot water, cooling water, fire-fighting water, oil, drinking water, cleaning agents, service water.
Etachrom BC PumpDrive
DN ______________ 25 - 80Q [m3/h] _______ max. 260H [m] __________ max. 106p [bar] __________ max. 12T [°C] ________ max. +110n [min-1] ______ max. 3500
Reference no. 1213.5-10 + 4070.5-10
Close-coupled chrome steel pump with motor-mounted variable speed system
Design: Horizontal, single-stage annular casing pump, with ratings and main dimensions to EN 733, with replaceable casing wear rings. ATEX-compliant version available.
Applications: Water supply, spray irrigation, irrigation and drainage systems, hea-ting and air-conditioning systems, fire-fighting systems, handling of drinking water, service water, hot water, cooling water, swimming pool water, fire-fighting water, condensate, oil and cleaning agents.
Etachrom NC
DN ______________ 25 - 80Q [m3/h] _______ max. 260H [m] __________ max. 106p [bar] __________ max. 12T [°C] ________ max. +110Data for 50 Hz operation
Reference no. 1212.5-10 also available in 60 HzPumpMeter · Hyamaster
Standardized chrome steel pump
Design: Horizontal, single-stage annular casing pump, with ratings and main dimensions to EN 733, with replaceable casing wear rings and motor-mounted variable speed system.
Applications: Water supply, spray irrigation, irrigation and drainage systems, hea-ting and air-conditioning systems, fire-fighting systems, handling of drinking water, service water, hot water, cooling water, swimming pool water, fire-fighting water, condensate, oil and cleaning agents.
Etachrom NC PumpDrive
DN ______________ 25 - 80Q [m3/h] _______ max. 260H [m] __________ max. 106p [bar] __________ max. 12T [°C] ________ max. +110n [min-1] ______ max. 3500
Reference no. 1212.5-10 + 4070.5-10
Standardized chrome steel pump with motor-mounted variable speed system
PumpMeter
PumpMeter
21Automation possible
S t a n d a r d i z e d / c l o s e - c o u p l e d p u m p s , f i x e d / v a r i a b l e s p e e d
Design: Single-stage volute casing pump, ratings to EN 733, for vertical installa-tion in closed tanks under atmospheric pressure. Up to an immersion depth of 2000 mm.
Applications: Handling of neutral degreasing and phosphatizing solutions, wash water with degreasing agents, dipping paints, etc.
Etanorm GPV/CPV
DN _____________ 32 - 150Q [m3/h] _______ max. 660H [m] __________ max. 102p [bar] __________ max. 16T [°C] _________ max. +95Data for 50 Hz operation
Reference no. 1214.5-10 also available in 60 Hz
Vertical low-pressure pump
Design: Horizontal, radially split volute casing pump in back pull-out design to EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller. Equipped with heat barrier, seal chamber air-cooled by integrated fan impeller, noexternal cooling. ATEX-compliant version available.
Applications: Handling of hot water and thermal oil in piping or tank systems, particularly in medium -sized and large hot water heating systems, forced circulation boilers, district heating systems, etc.
HPK-L
DN _____________ 25 - 250Q [m3/h] ______ max. 1330H [m] __________ max. 155p [bar] __________ max. 40T [°C] _ max. +240 / +350Data for 50 Hz operation
Reference no. 1136.5-10 also available in 60 HzPumpDrive • Hyamaster
Hot water / thermal oil recirculation pump without external cooling
Design: Horizontal, radially split volute casing pump in back pull-out design to EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller. TÜV certification to TRD on option. ATEX-compliant version available.
Applications: Handling of hot water and thermal oil in piping or tank systems, particularly in medium-sized and large hot water heating systems, forced circulation boilers, district heating systems, etc.
HPK
Reference no. 1121.51-10 also available in 60 HzPumpDrive • Hyamaster
Hot water recirculation pump
DN ____________150 - 400Q [m3/h] ______ max. 4150H [m] __________ max. 185p [bar] __________ max. 40T [°C] ________ max. +400Data for 50 Hz operation
H o t w a t e r p u m p s
Design: Horizontal, radially split volute casing pump in back pull-out design, single-stage, single-entry, with centreline pump feet and radial impeller. TÜV certification to TRD on option. ATEX-compliant version available.
Applications: Handling of hot water in high-pressure hot water generation plants and for use as boiler feed and recirculation pump.
HPH
DN _____________ 40 - 350Q [m3/h] ______ max. 2350H [m] __________ max. 225p [bar] _________ max. 110T [°C] ________ max. +320Data for 50 Hz operation
Reference no. 1122.5-10 also available in 60 HzHyamaster
Hot water recirculation pump
22
H o t w a t e r / t h e r m a l o i l p u m p s
Design: Horizontal, long-coupled volute casing pump in back pull-out design with ratings and main dimensions to EN 733, single-stage, with replaceable casing wear rings. ATEX-compliant version available.
Applications: Heat transfer systems (DIN 4754, VDI 3033) or hot water recircula-tion (DIN 4752).
Etanorm SYT / RSY
DN _____________ 32 - 300Q [m3/h] ______ max. 1900H [m] __________ max. 102p [bar] __________ max. 16T [°C] ________ max. +350Data for 50 Hz operation
Reference no. 1220.5-10 also available in 60 HzHyamaster
Hot water / thermal oil pump
Automation possible
Design: Horizontal, single-stage volute casing pump in back pull-out design with ratings and main dimensions to EN 733, or in in-line design, with replaceable casing wear rings.
Applications: Heat transfer systems (DIN 4754) or hot water recirculation.
Etabloc SYT / Etaline SYT
DN _____________ 32 - 100Q [m3/h] _______ max. 280H [m] ___________ max. 67p [bar] __________ max. 16T [°C] ________ max. +350Data for 50 Hz operation
Reference no. 1170.5-10 also available in 60 HzHyamaster
Hot water / thermal oil pump
Design: Horizontal, seal-less, single-stage volute casing pump with magnetic drive, ratings and main dimensions to EN 733, with replaceable casing wear rings.
Applications: Handling of thermal oil in heat transfer systems to DIN 4754.
Etamagno SY / SYI / Bloc SY
DN ___________ 32 - 150Q [m3/h] _______ max. 660H [m] _________ max. 102p [bar] _________ max. 16T [°C] _______ max. +350Data for 50 Hz operation
Reference no. 1218.5-10 also available in 60 HzHyamaster
Thermal oil pump
T h e r m a l o i l p u m p s w i t h m a g n e t i c d r i v e / c a n n e d m o t o r
Design: Horizontal, seal-less, single-stage pump with fully enclosed canned motor, uncooled. ATEX-compliant version available.
Applications: Handling of thermal oils and other hot fluids in heat transfer systems to DIN 4754.
HX (Nikkiso-KSB)
DN __________ 32 - 100Q [m3/h] ______ max. 200H [m] _________ max. 100p [bar] _________ max. 40T [°C] ______ max. +350Data for 50 Hz operation
also available in 60 Hz
Thermal oil pump with explosion protection
(Only available in Europe, Russia, Middle East and Africa)
23
T h e r m a l o i l p u m p s w i t h m a g n e t i c d r i v e / c a n n e d m o t o r
Design: Horizontal, seal-less, single-stage pump with fully enclosed canned motor, uncooled, coolable or heatable. ATEX-compliant version available.
Applications: Handling of thermal oils and other hot fluids in heat transfer systems to DIN 4754.
HY (Nikkiso-KSB)
DN ____________ 32 - 80Q [m3/h] ______ max. 150H [m] _________ max. 100p [bar] _________ max. 40T [°C] _______ max. +250Data for 50 Hz operation
also available in 60 Hz
Thermal oil pump with explosion protection
(Only available in Europe, Russia, Middle East and Africa)
Design: Horizontal, radially split volute casing pump in back pull-out design to EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller. Also available as variant with “wet” shaft, conical seal chamber and/or semi-open impeller (CPKNO) with motor-mounted variable speed system.
Applications: Handling of aggressive liquids in the chemical and petrochemical industries as well as in refinery and fire-fighting systems, handling of brine.
DN _____________ 25 - 300Q [m3/h] ______ max. 1050H [m] __________ max. 220p [bar] __________ max. 25T [°C] ________ max. +110n [min-1] ______ max. 3600
Reference no. 2730.5-10 + 4070.5-10
Standardized chemical pump with reinforced bearing bracket and motor-mounted variable speed systemCPKN PumpDrive
CPK-D
DN _____________ 32 - 250Q [m3/h] ______ max. 1100H [m] __________ max. 128p [bar] __________ max. 25T [°C] ________ max. +150 Data for 50 Hz operation
Reference no. 2726.1-10 also available in 60 HzHyamaster
Standardized chemical pump with hydrodynamic shaft seal
Design: Horizontal, radially split volute casing pump in back pull-out design to ISO 2858, single-stage, single-entry, with radial impeller and zero-leakage hydrodynamic shaft seal.
Applications: Handling of liquids in the chemical and petrochemical industry, in refineries and paint shops.
S t a n d a r d i z e d c h e m i c a l p u m p s
Reference no. 2730.5-10 also available in 60 Hz
CPKN Standardized chemical pump with reinforced bearing bracket
Design: Horizontal, radially split volute casing pump in back pull-out design to EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller. Also available as variant with “wet” shaft, conical seal chamber, heatable volutecasing (CPKN-CHs) and/or semi-open impeller (CPKNO). ATEX-compliant version available. Applications: Handling of aggressive liquids in the chemical and petrochemicalindustries as well as in refinery and fire-fighting systems, handling of brine.
DN _____________ 25 - 400Q [m3/h] ______ max. 4150H [m] __________ max. 185p [bar] __________ max. 25T [°C] ________ max. +400Data for 50 Hz operation
Hyamaster
Automation possibleFactory-automated
24 Automation possible
Design: Horizontal, seal-less, close-coupled, mag-drive volute casing pump to ISO 2858 / EN 22 858 / ISO 5199, single-stage, single-entry, with radial impeller. ATEX-compliant version available.
Applications: Handling of aggressive, toxic, explosive, valuable, flammable, mal odorous or harmful liquids in the chemical, petrochemical and general industry.
Magnochem - Bloc
DN _____________ 25 - 125Q [m3/h] _______ max. 240H [m] __________ max. 153p [bar] __________ max. 25T [°C] ________ max. +250Data for 50 Hz operation
Reference no. 2749.5-10 also available in 60 HzHyamaster
Close-coupled chemical pump with mag-drive
Design: Horizontal / vertical, seal-less volute casing pump in back pull-out design with fully enclosed canned motor, low noise emission, with radial impeller, single-stage, single-entry, pump casing connecting dimensions to EN 733.
Applications: Handling of aggressive, flammable, toxic, volatile, or valuable liquids in the chemical and petrochemical industry, in environmental engineering and the general industry.
Etaseco / Etaseco-I
DN _____________ 32 - 100Q [m3/h] _______ max. 250H [m] __________ max. 100p [bar] __________ max. 16T [°C] ________ max. +140Data for 50 Hz operation
Reference no. 2935.5-10 also available in 60 HzPumpMeter • Hyamaster • PumpDrive
Water motor pumps with canned motor
Design: Horizontal, seal-less volute casing pump in back pull-out design with fully enclosed canned motor, low noise emission, with radial impeller, single-stage, single -entry, casing connecting dimensions to EN 22 858 / ISO 2858. Design to ATEX.
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or valuable liquids in the chemical and petrochemical industry, in environmental engineering and the general industry.
Secochem Ex
DN _____________ 25 - 100Q [m3/h] _______ max. 300H [m] __________ max. 150p [bar] __________ max. 25T [°C] ________ max. +130Data for 50 Hz operation
Reference no. 2939.5-10 also available in 60 HzHyamaster
Standardized chemical pump with canned motor and explosion protection
S e a l - l e s s p u m p s
Design: Horizontal, seal-less, mag-drive volute casing pump in back pull-outdesign to ISO 2858 / EN 22 858 / ISO 5199, single-stage, single-entry, with radial impeller. ATEX-compliant version available.
Applications: Handling of aggressive, toxic, explosive, valuable, flammable, malodorous or harmful liquids in the chemical, petrochemical and general industry.
Magnochem
DN ____________ 25 - 250Q [m3/h] ______ max. 1250H [m] __________ max. 153p [bar] __________ max. 25T [°C] ________ max. +300Data for 50 Hz operation
Reference no. 2739.5-10 also available in 60 HzHyamaster
Standardized chemical pump with mag-drive
Design: Horizontal/vertical seal-less volute casing pump in back pull-out design with fully enclosed canned motor, low noise emission, with radial impeller, single-stage, single-entry.
Applications: Pump for handling toxic, volatile or valuable fluids in environmen-tal and industrial engineering and for use as a coolant pump in cooling systems. Transport vehicles, environmental and industrial engineering; applications where low noise emission, smooth running or long service intervals are required.
Etaseco RVP
DN __________________ 32Q [m3/h] ________ max. 20H [m] ___________ max. 25p [bar] __________ max. 10T [°C] _________ max. +85
Reference no. 2935.17-10 also available in 60 HzPumpMeter • PumpDrive
Cooling circuit pump with canned motor
25Automation possible
S e a l - l e s s p u m p s
Design: Horizontal, seal-less volute casing pump in back pull-out design with fully enclosed canned motor, low noise emission, with radial impeller, single-stage, single -entry, pump casing connecting dimensions to EN 22 858 / ISO 2858, with external cooler. Design to ATEX.
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or valuable liquids in the chemical and petrochemical industry, in environmental engineering and the general industry.
Secochem Ex K
DN _____________ 25 - 100Q [m3/h] _______ max. 300H [m] __________ max. 150p [bar] __________ max. 25T [°C] ________ max. +400Data for 50 Hz operation
Reference no. 2939.51-10 also available in 60 HzHyamaster
Standardized chemical pump with canned motor and explosion protection
Design: Horizontal (HN) or vertical (BN / TN), seal-less, single-stage pump with fully enclosed canned motor, uncooled, coolable or heatable. ATEX-compliant version available.
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or valuable liquids in the chemical and petrochemical industry.
HN / BN / TN (Nikkiso-KSB)
DN _____________ 32 - 300Q [m3/h] _______ max. 800H [m] __________ max. 200p [bar] __________ max. 40T [°C] ________ max. +180Data for 50 Hz operation
also available in 60 Hz
Chemical canned motor pump with explosion protection
Design: Horizontal (HT) or vertical (BT /TT), seal-less, single-stage pump with fully enclosed canned motor, coolable. ATEX-compliant version available.
Applications: Handling of aggressive, solids-containing, polymerizing, flammable, explosive, toxic, volatile or valuable liquids as well as thermal oils in the chemical and petrochemical industry.
HT / BT / TT (Nikkiso-KSB)
DN _____________ 32 - 300Q [m3/h] _______ max. 800H [m] __________ max. 200p [bar] __________ max. 40T [°C] ________ max. +400Data for 50 Hz operation
also available in 60 Hz
Chemical canned motor pump with explosion-protection for special applications
Design: Horizontal, seal-less pump with fully enclosed canned motor, two-stage design in tandem arrangement. ATEX-compliant version available.
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or valuable liquids in the chemical and petrochemical industry. For small flow rates, high discharge heads and low NPSHR.
HK (Nikkiso-KSB)
DN ______________ 25 - 40Q [m3/h] ________ max. 10H [m] __________ max. 300p [bar] __________ max. 40T [°C] ________ max. +150n [min-1] ______ max. 8400Data for n = 8400 min-1
high speed, up to 130 Hz
Two-stage canned motor pump with explosion protection
Design: Horizontal, seal-less pump with fully enclosed canned motor, multistage. ATEX-compliant version available.
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or valuable liquids in the chemical and petrochemical industry. For high discharge heads.
VN (Nikkiso-KSB)
DN _____________ 40 - 100Q [m3/h] _______ max. 140H [m] __________ max. 450p [bar] __________ max. 40T [°C] ________ max. +180Data for 50 Hz operation
also available in 60 Hz
Multistage canned motor pump with explosion protection
(Only available in Europe, Russia, Middle East and Africa)
(Only available in Europe, Russia, Middle East and Africa)
(Only available in Europe, Russia, Middle East and Africa)
(Only available in Europe, Russia, Middle East and Africa)
26
S e a l - l e s s p u m p s
Design: Horizontal, seal-less pump with fully enclosed canned motor, single stage, self-priming. ATEX-compliant version available.
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or valuable liquids in the chemical and petrochemical industry. Self-priming pump for draining of tanks and unloading of tanks and tank trucks.
DN (Nikkiso-KSB)
DN ______________ 32 - 50Q [m3/h] ________ max. 40H [m] ___________ max. 60p [bar] __________ max. 40T [°C] ________ max. +180Data for 50 Hz operation
also available in 60 Hz
Self-priming canned motor pump with explosion protection
(Only available in Europe, Russia, Middle East and Africa)
P r o c e s s p u m p s
Design: Horizontal, radially split volute casing pump in back pull-out design to API 610, 10th edition, or ISO 13709 (heavy duty), with radial impeller, single-stage, single-entry, centreline pump feet; with inducer, if required. ATEX-compliant version available.
Applications: Refineries, petrochemical and chemical industry, power stations.
RPH
DN _____________ 25 - 400Q [m3/h] ______ max. 4150H [m] __________ max. 270p [bar] __________ max. 51T [°C] ________ max. +450Data for 50 Hz operation
Reference no. 1312.5-10 / 1316.51 -10 also available in 60 HzHyamaster
Process pump
Design: Radially split, vertical shaft submersible pump with double volute for wet and dry installation, single- or double-stage, single-entry, with radial impeller; heatable model available. ATEX-compliant version available.
Applications: Handling of chemically aggressive liquids, also slightly contaminated or with a low solids content, in the chemical and petrochemical industry.
CTN
DN _____________ 25 - 250Q [m3/h] _______ max. 800H [m] ___________ max. 93p [bar] __________ max. 16T [°C] ________ max. +300Data for 50 Hz operation
Reference no. 2711.5-10 also available in 60 Hz
Chemical vertical shaft submersible pump
Design: Horizontal or vertical canned motor pump to API 685, single-stage, with centreline pump feet; also available with inducer.
Applications: HNP: for clean liquids; HTP: for hot fluids; HSP / HMP: for contam-inated or polymerising fluids; HRP: for fluids with a steep vapour pressure curve such as liquefied gases.
API series (Nikkiso-KSB)
DN ______________ 1½ - 6Q [m3/h] _______ max. 360H [m] __________ max. 220p [bar] __________ max. 40T [°C] ________ max. +450Data for 50 Hz operation
also available in 60 Hz
Refinery pump
(Only available in Europe, Russia, Middle East and Africa)
Automation possible
27
C e n t r i f u g a l p u m p f o r m i n i m a l v o l u m e f l o w s
A
Design: System consisting of a variable-speed single-stage centrifugal pump with directly flanged motor and control unit.
Applications: Continuous volume flow control for handling aggressive organic and inorganic fluids in chemical and pharmaceutical processes. The pump is suitable for use in laboratories, pilot plants and in production processes, particularly in industrial process engineering, continuous processes, micro-process engineering, miniplants, dosing, coating, spray-drying and injection applications.
Microchem
Q [ml/min] _____ 0 to 5000H [m] __________ max. 200p [bar] __________ max. 25T [°C] _______ -10 to +100
Reference no. 2600.5-10
Centrifugal pump for minimal volume flows
R a i n w a t e r h a r v e s t i n g s y s t e m s
A
Design: Ready-to-connect package rainwater harvesting system. Automatic mains water back-up if the rain water storage tank is empty, with integrated dry-running protection. Automated with automatic control unit.
Applications: Rainwater and service water utilization, irrigation and spray irrigation systems.
Hya-Rain / Hya-Rain N
Rp ___________________ 1Q [m3/h] _________ max. 4H [m] ___________ max. 43p [bar] ___________ max. 6T [°C] _________ max. +35Data for 50 Hz operation
Reference no. 5602.51-10
Rainwater harvesting system with one pump
A
Design: Ready-to-connect package rainwater harvesting system. Automatic mains water back-up function if the rain water storage tank is empty, with integrated dry-running protection.
Applications: Rainwater and service water utilization, irrigation and spray irrigation systems.
Hya-Rain Eco
Rp ___________________ 1Q [m3/h] _________ max. 4H [m] ___________ max. 43p [bar] ___________ max. 6T [°C] _________ max. +35Data for 50 Hz operation
Reference no. 5605.5-10
Rainwater harvesting system with one pump
Factory-automated
28
D o m e s t i c w a t e r s u p p l y s y s t e m s
w i t h a u t o m a t i c c o n t r o l u n i t / s w i m m i n g p o o l s
Design: Multistage, self-priming centrifugal pump in close-coupled design.
Applications: Single- or two-family houses, agricultural facilities, spray irrigation and irrigation systems, washing plants, water supply and rainwater harvesting systems.
Multi Eco
Rp _______________ 1-1¼
Q [m3/h] _________ max. 8H [m] ___________ max. 54p [bar] __________ max. 10T [°C] _________ max. +50n [min-1] ______ max. 2800
Reference no. 5180.5-10Controlmatic • Cervomatic
Multistage, self-priming centrifugal pump
Design: Multistage, self-priming centrifugal pump in close-coupled design, withpower cable, plug and Controlmatic E automatic control unit switching the pump on and off as consumers are opened / closed and protecting the pump against dry running. Automated with automatic control unit.
Applications: Single- or two-family houses, agricultural facilities, spray irrigation and irrigation systems, washing plants, water supply and rainwater harvesting systems.
Multi Eco-Pro
Rp _______________ 1-1¼
Q [m3/h] _________ max. 8H [m] ___________ max. 54p [bar] __________ max. 10T [°C] _________ max. +50n [min-1] ______ max. 2800
Reference no. 5182.5-10
Multistage, self-priming centrifugal pump with automatic control unit
Automation possibleFactory-automated
A
Design: Multistage, self-priming centrifugal pump in close-coupled design incl.accumulator with replaceable membrane in drinking water quality, total volume 20 or 50 l, pressure switch for automatic pump operation and 1.5 m power cable. Automated with automatic control unit.
Applications: Single- or two-family houses, agricultural facilities, spray irrigation and irrigation systems, washing plants, water supply and rainwater harvesting systems.
Multi Eco-Top
Rp _______________ 1-1¼
Q [m3/h] _________ max. 8H [m] ___________ max. 54p [bar] ___________ max. 7T [°C] _________ max. +50n [min-1] ______ max. 2800
Reference no. 5181.5-10
Domestic water supply system
A
Design: Multistage, vertical (horizontal installation upon request) high-pressure centrifugal pump, with suction and discharge nozzles of identical nominal diameters arranged opposite to each other (in-line design).
Applications: Single- or two-family houses, agricultural facilities, spray irrigation and irrigation systems, washing plants, water supply and rainwater harvesting systems, pressure boosting, hot water and cooling water recirculation, fire-fighting systems.
Movitec VME
Rp _________________ 1½Q [m3/h] _________ max. 9H [m] ___________ max. 48p [bar] __________ max. 16T [°C] _________ max. +60n [min-1] ______ max. 2900Data for 50 Hz operation
Reference no. 1798.5-10 also available in 60 HzPumpMeter • Hyamaster
High-pressure in-line pump in close-coupled design
Design: Fully or partly submerged, multistage, close-coupled centrifugal pump (min. immersion depth 0.1 m), low-level inlet, suction strainer with a max. mesh size of 2.5 mm.
Applications: Water supply, spray irrigation and irrigation systems, washing plants, rainwater harvesting systems, water extraction from wells, tanks and cisterns.
Ixo
Rp _________________ 1¼Q [m3/h] _________ max. 8H [m] ___________ max. 65T [°C] _________ max. +35n [min-1] ______ max. 2900
Reference no. 2146.5-10Switchgears • Cervomatic
Submersible motor pump
29Factory-automated
D o m e s t i c w a t e r s u p p l y s y s t e m s
w i t h a u t o m a t i c c o n t r o l u n i t / s w i m m i n g p o o l s
A
Design: Self-priming, single-stage, close-coupled centrifugal pump.
Applications: Handling of clean or slightly contaminated water, swimming pool water with a chlorine content of up to 0.3 %, ozonized swimming pool water with a salt content of up to 7 ‰.
Filtra N
Rp ___________________ 2Q [m3/h] ________ max. 36H [m] ___________ max. 21p [bar] _________ max. 2.5T [°C] _________ max. +35n [min-1] ______ max. 2800
Reference no. 2127.5-10
Recirculating pump for swimming pool filtering systems
P r e s s u r e b o o s t e r s y s t e m s
A
Design: Fully automatic package single-pump system with 8 l membrane-type accumulator, pressure-controlled starting and flow-controlled stopping. Automated with automatic control unit.
Applications: Water supply systems for residential and office buildings, irrigation/spray irrigation and rainwater harvesting systems, service water supply systems in trade and industry.
Hya-Solo E
Rp _________________ 1¼
Q [m3/h] _________ max. 6H [m] ___________ max. 50p [bar] __________ max. 10T [°C] _________ max. +60Data for 50 Hz operation
Reference no. 1951.5-10
Pressure booster system, 1 pump
A
Design: Fully automatic package single-pump system with 8 l membrane-type accumulator, pressure-controlled starting and stopping.
Applications: For industrial plants, water supply systems for residential and office buildings, irrigation/spray irrigation and rainwater harvesting systems, service water supply systems in trade and industry.
Hya-Solo D
Rp / DN ________ 1¼ / 100Q [m3/h] _______ max. 110H [m] __________ max. 150p [bar] __________ max. 16T [°C] _________ max. +70Data for 50 Hz operation
Reference no. 1951.5-10
Pressure booster system, 1 pump
A
Design: Fully automatic variable-speed package single-pump system with PumpDrive, pressure-controlled starting and flow-controlled stopping. Automated with PumpDrive.
Applications: For industrial plants, water supply systems for residential and office buildings, irrigation/spray irrigation and rainwater harvesting systems, service water supply systems in trade and industry.
Hya-Solo DV
Rp / DN ________ 1¼ / 100Q [m3/h] _______ max. 110H [m] __________ max. 150p [bar] __________ max. 16T [°C] _________ max. +70Data for 2900 min-1
Reference no. 1951.5-10
Pressure booster system, 1 pump
30
A
Design: Fully automatic package pressure booster system, with 2 to 3 vertical high-pressure pumps, fully electronic control to ensure the required supply pressure, standard version with volt-free changeover contact for general fault indication and live-zero monitoring of the connected sensors, configuration and functions to DIN 1988, Part 5. Automated with BoosterControl.
Applications: Residential buildings, hospitals, office buildings, hotels, department stores, industry, etc.
Hya-Eco K
Rp / DN ___________ 2 / 80Q [m3/h] ________ max. 70H [m] __________ max. 100p [bar] __________ max. 10T [°C] _________ max. +70Data for 50 Hz operation
Reference no. 1967.5-10
Pressure booster system, 2 to 3 pumps
A
Design: Fully automatic package pressure booster system, with 2 to 3 vertical high-pressure pumps and continuously variable speed adjustment of each pump for fully electronic control of the required supply pressure, with two standard volt-free changeover contacts for fault indication. Configuration and function to DIN 1988, Part 5. Automated with BoosterControl.
Applications: Residential buildings, hospitals, office buildings, hotels, department stores, industry, and other applications.
Hya-Eco VP
Rp / DN ___________ 2 / 80Q [m3/h] ________ max. 70H [m] __________ max. 120p [bar] __________ max. 12T [°C] _________ max. +70Data for 3500 min-1
Reference no. 1967.52-10
Pressure booster system with continuously variable speed control of each pump
Design: Fully automatic package pressure booster system, with 2 to 6 vertical high-pressure pumps, fully electronic control to ensure the required supply pres-sure, with volt-free changeover contact for general fault indication and live-zero monitoring of the connected sensors, configuration and functions to DIN 1988, Part 5. Automated with BoosterControl.
Applications: Residential buildings, hospitals, office buildings, hotels, department stores, industry, etc.
Hyamat K
Rp / DN ________ 1½ / 250Q [m3/h] _______ max. 660H [m] __________ max. 160p [bar] __________ max. 16T [°C] _________ max. +70Data for 50 Hz operation
Reference no. 1952.5-10
Pressure booster system, 2 to 6 pumps
Hyamat V Pressure booster system with continuously variable speed adjustment of one pump
Design: Fully automatic package pressure booster system, with 2 to 6 vertical high-pressure pumps and continuously variable speed adjustment of one pump for fully electronic control of the required supply pressure. Configuration and functions to DIN 1988, Part 5. Automated with BoosterControl.
Applications: Pressure boosting in residential buildings, hospitals, office buildings, hotels, department stores, industry, etc.
Rp / DN ________ 1½ / 250Q [m3/h] _______ max. 660H [m] __________ max. 160p [bar] __________ max. 16T [°C] _________ max. +70Data for 2900 min-1
Reference no. 1953.51-10
Design: Fully automatic package pressure booster system, with 2 to 6 vertical high-pressure pumps and continuously variable speed control of each pump byPumpDrive speed control system. For fully electronic control of the required sup-ply pressure. Configuration and functions to DIN 1988, Part 5. Automated with BoosterControl and PumpDrive.
Applications: Pressure boosting in residential buildings, hospitals, office buildings, hotels, department stores, industry, etc.
Hyamat VP
Rp / DN ________ 1½ / 250Q [m3/h] _______ max. 660H [m] __________ max. 160p [bar] __________ max. 16T [°C] _________ max. +70Data for 2900 min-1
Reference no. 1953.52-10
Pressure booster system with continuously variable speed control of each pump
P r e s s u r e b o o s t e r s y s t e m s
Factory-automated
31
P r e s s u r e b o o s t e r s y s t e m s
A
Design: Fully automatic package pressure booster system, with 2 to 4 vertical high-pressure pumps and fully electronic control to ensure the required supply pressure, configuration and functions to DIN 1988, Part 5. Automated with PLC.
Applications: Handling of service water and cooling water not chemically or mechanically aggressive to the pump materials in industry, etc.
Hyamat IK, IV, IVP
DN ____________ 100 - 200Q [m3/h] _______ max. 640H [m] __________ max. 160p [bar] __________ max. 16T [°C] _________ max. +70Data for 50 Hz operation
Reference no. 1950.5-10
Pressure booster system for industrial applications
D r a i n a g e p u m p s / w a s t e w a t e r p u m p s
Design: Vertical, fully floodable submersible motor pump in close-coupled design, IP 68, single-stage, with or without level control, max. immersion depth 2 m.
Applications: Automatic drainage of pits, shafts, yards and cellars subject to a flooding risk, lowering of surface water levels, dewatering, drainage of under-ground passages, water extraction from rivers and reservoirs.
Ama-Drainer N 301, 302, 303, 358
Rp _____________ 1¼ - 1½
Q [m3/h] ________ max. 17H [m] ___________ max. 12T [°C] _________ max. +35Data for 50 Hz operation
Reference no. 2331.51-10 / 2331.52-10 Switchgears • LevelControl
Submersible motor pump
Design: Vertical, fully floodable submersible motor pump in close-coupled design, IP 68, single-stage, with or without level control, max. immersion depth 10 m.
Applications: Automatic drainage of pits, shafts, yards and cellars subject to a flooding risk, lowering of surface water levels, dewatering, drainage of under-ground passages, water extraction from rivers and reservoirs, disposal of highly contaminated, fibre-containing water.
Ama-Drainer 400/10 400/35 500/10/11
Rp ______________ 1½ - 2Q [m3/h] ________ max. 50H [m] ___________ max. 24T [°C] _________ max. +40Data for 50 Hz operation
Reference no. 2331.53-10Switchgears • LevelControl
Submersible motor pump
Design: Vertical, fully floodable submersible motor pump in close-coupled design, IP 68, single-stage, with or without level control, max. immersion depth 10 m.
Applications: Automatic drainage of pits, shafts, yards and cellars subject to a flooding risk, lowering of surface water levels, dewatering, drainage of under-ground passages, water extraction from rivers and reservoirs.
Ama-Drainer 80, 100
Rp / DN _______ 2½ / 100Q [m3/h] _______ max. 130H [m] ___________ max. 26T [°C] _________ max. +50Data for 50 Hz operation
Reference no. 2331.54-10Switchgears • LevelControl
Submersible motor pump
Automation possibleFactory-automated
32
Design: Vertical, fully floodable submersible waste water pump in close-coupleddesign (cast iron variant), single-stage, without explosion protection.
Applications: Handling of all types of waste water.
Ama-Porter F / S / ICS
DN ______________ 50 - 65Q [m3/h] ________ max. 40H [m] ___________ max. 21T [°C] _________ max. +40Data for 50 Hz operation
Reference no. 2541.51-10 / 2539.51-10 / 2539.52-10 / 2539.53-10(ICS)
Submersible motor pump
Design: Vertical, single-stage centrifugal pump with discharge to the top and par-allel with the pump shaft, pump foot designed as suction strainer. Pump and motor are rigidly connected by a support pipe, ready to be plugged in, with 1.5 m power cable and level switch.Applications: Automatic disposal of waste water from buildings, pits and tanks, lowering of surface water levels and drainage.
Rotex
Rp ______________ 1¼ - 2Q [m3/h] ________ max. 24H [m] ___________ max. 14T [°C] _________ max. +90Data for 50 Hz operation
Reference no. 2322.5-10
Waste water pump
Switchgears • LevelControl (Ama-Porter F/S)
D r a i n a g e p u m p s / w a s t e w a t e r p u m p s
Design: Vertical submersible pump with three-channel impeller, volute casing designed as suction strainer.
Applications: Handling of condensate and heat transfer liquids below the boiling point, condensate return systems, primary and secondary heating circuits, direct installation in heating tanks or heat exchangers in the secondary circuits of heat transfer systems (MKY).
MK / MKY
Rp / DN ___________ 2 / 50Q [m3/h] ________ max. 36H [m] ___________ max. 19T [°C] ________ max. +200Data for 50 Hz operation
Reference no. 2324.5-10Switchgears • LevelControl
Waste water, condensate and heat transfer liquid pump
Automation possibleFactory-automated
33
L i f t i n g u n i t s / c o l l e c t i n g t a n k s
Design: Stable above-floor or impact-resistant underfloor plastic collecting tankwith floor drain and odour trap, both variants with Ama-Drainer submersible motor pump starting and stopping automatically and swing check valve. Automated with switchgears and LevelControl.Applications: Wash-basins, showers, washing machines, garage gateways, base-ments, rooms subject to a flooding risk, etc.
Ama-Drainer-Box
DN ______________ 40 - 50Q [m3/h] ________ max. 35H [m] ___________ max. 21T [°C] _________ max. +40Data for 50 Hz operation
Reference no. 2331.55-10
Automatic waste water lifting unitReleased for sale until March 2011 –
to be superseded by new Ama Drainer Box.
Design: Floodable single-pump or dual-pump sewage lifting unit for automatic disposal of domestic sewage and faeces below the flood level. Automated with LevelControl.
Applications: Basement flats, bars, basement party rooms and saunas, cinemas and theatres, department stores and hospitals, hotels, restaurants, schools, etc.
mini-Compacta
DN _____________ 32 - 100Q [m3/h] ________ max. 36H [m] ___________ max. 25T [°C] _________ max. +40Data for 50 Hz operation
Reference no. 2317.54-10
Floodable sewage lifting unit
Design: Floodable single-pump or dual-pump sewage lifting unit for automatic disposal of sewage and faeces below the flood level. Automated with LevelControl.
Applications: Basement flats, bars, basement party rooms and saunas, cinemas and theatres, department stores and hospitals, hotels, restaurants, schools, public buildings, industrial plants, joint sewage disposal for rows of houses, etc.
Compacta®
DN _____________ 80 - 100Q [m3/h] _______ max. 140H [m] ___________ max. 24T [°C] _______ max. +40*Data for 50 Hz operation
Reference no. 2317.55-10
Floodable sewage lifting unit
* up to +65 °C for short periods
A
Design: Ready-to-connect package single or dual pumping station with PE-LLD(polyethylene) collecting tank for underground installation. Equipped with one or two Amarex N S and Ama-Porter submersible waste water pumps without explo-sion protection. Collecting tank design to DIN 1986-100 and EN 752 / EN 476. Automated with LevelControl.
Applications: Renovation of premises, sewage disposal in various sectors, joint sewage disposal for several residential units, pumped drainage.
Pumping Station CK 800-Eu
DN ______________ 32 - 50Q [m3/h] ________ max. 22H [m] ___________ max. 49T [°C] _________ max. +40Data for 50 Hz operation
Reference no. 2334.541-10
Pumping station, plastic collecting tank with Amarex N S and Ama-Porter
Factory-automated
34
L i f t i n g u n i t s / c o l l e c t i n g t a n k s
LevelControl
Design: Ready-to-connect package single or dual pumping station with PE-LLD(polyethylene) collecting tank for underground installation. Equipped with one or two Amarex N submersible waste water pumps, also available with explosion pro-tection. Collecting tank design to DIN 1986-100 and EN 752 / EN 476. Automated with LevelControl.
Applications: Renovation of premises, sewage disposal in various sectors, joint sewage disposal for several residential units, pumped drainage.
Amarex N CK Pumping Station
DN ______________ 50 - 65Q [m3/h] ________ max. 50H [m] ___________ max. 39T [°C] _________ max. +40Data for 50 Hz operation
Pumping station, plastic collecting tank with Amarex N
Reference no. 2334.52-10
LevelControl
Design: Single-pump or dual-pump sewage lifting unit with one or two Ama-Porter submersible waste water pumps with free-flow impeller (F) or cutter (S), to EN 12050-1.
Applications: Disposal of domestic waste water and sewage.
Evamatic-Box
DN ______________ 50 - 65Q [m3/h] ________ max. 40H [m] ___________ max. 21T [°C] _________ max. +40Data for 50 Hz operation
Sewage lifting unit
Reference no. 2319.51-10
LevelControl
Design: Single-pump or dual-pump sewage lifting unit with one or two Ama-Porter ICS submersible waste water pumps with free-flow impeller (F) or cutter (S) and ICS control system.
Applications: Disposal of domestic waste water and sewage.
Evamatic-Box ICS
DN ______________ 50 - 65Q [m3/h] ________ max. 40H [m] ___________ max. 21T [°C] _________ max. +40Data for 50 Hz operation
Sewage lifting unit
Reference no. 2319.52-10
Released for sale until March 2011 –
to be superseded by Evamatic Box N.
Released for sale until March 2011 –
to be superseded by Evamatic Box N ICS.
A
Design: Ready-to-connect package single or dual pumping station with PE-LLD(polyethylene) collecting tank for underground installation. Equipped with one or two Ama-Porter submersible waste water pumps without explosion protection. Collecting tank design to DIN 1986-100 and EN 752 / EN 476. Automated with switchgears and LevelControl.
Applications: Renovation of premises, sewage disposal in various sectors, joint sewage disposal for several residential units, pumped drainage.
Ama-Porter CK Pumping Station
DN ______________ 50 - 65Q [m3/h] ________ max. 40H [m] ___________ max. 21T [°C] _________ max. +40Data for 50 Hz operation
Reference no. 2334.51-10
Pumping station, plastic collecting tank with Ama-Porter
Factory-automated
35
S u b m e r s i b l e m o t o r p u m p s
Design: Vertical, single-stage submersible motor pump, for wet installation, stationary and transportable design. Amarex N pumps are floodable, single-stage, single-entry close-coupled units which are not self-priming. ATEX-compliant version available.
Applications: Handling of all types of waste water, especially untreated sewage containing long fibres and solid substances, fluids containing gas / air, as well as raw, activated and digested sludge, dewatering / water extraction, drainage of rooms and surfaces subject to a flooding risk.
Amarex N
DN _____________ 32 - 100Q [m3/h] _______ max. 190H [m] ___________ max. 49T [°C] _________ max. +55Data for 50 Hz operation
Reference no. 2563.5-10 also available in 60 HzSwitchgears • LevelControl
Submersible motor pump DN 32 to 100
Design: Vertical, single-stage submersible motor pump in close-coupled design, various impeller types, for wet or dry installation, stationary and transportable version. ATEX-compliant version available.
Applications: Handling of all types of abrasive or aggressive waste water in water and waste water engineering as well as industry, especially untreated sewage containing long fibres and solid substances, fluids containing gas / air, as well as raw, activated and digested sludge; sea water desalination.
Amarex KRT
DN _____________ 40 - 700Q [m3/h] _____ max. 10800H [m] __________ max. 100T [°C] _________ max. +60n [min-1] ______ max. 2900Data for 50 Hz operation
Submersible motor pump DN 40 to DN 700
PumpDrive • Hyamaster • Amacontrol • Switchgears • LevelControl Reference no. 2553.5-10 also available in 60 Hz
Design: Vertical, single-stage submersible motor pump in close-coupled design, various impeller types, dry installation.
Applications: Handling of all types of waste water in waste water engineering and industry, especially sewage containing long fibres and solid substances, fluids containing gas / air, as well as raw, activated and digested sludge.
Amarex KRT dry-installed, with cooling jacket
DN ___________ 100 - 700Q [m3/h] _____ max. 10000H [m] __________ max. 100p [bar] __________ max. 10T [°C] _________ max. +40n [min-1] ______ max. 1450Data for 50 Hz operation
Reference no. 2553.5-10 also available in 60 HzPumpDrive • Hyamaster • Amacontrol • Switchgears • LevelControl
Submersible motor pump DN 100 to DN 700
Design: Horizontal or vertical single-stage submersible motor pump in close-coupled design, with various impeller types, for wet or dry installation, stationary and transportable version, with energy-saving motor.
Applications: Handling of all types of waste water in waste water engineering and industry, especially sewage containing long fibres and solid substances, fluids containing gas / air, as well as raw, activated and digested sludge.
Amarex KRT wet/dry-installed, with energy-saving motor
DN _____________ 80 - 200Q [m3/h] _______ max. 550H [m] ___________ max. 25T [°C] _________ max. +40n [min-1] ______ max. 1450Data for 50 Hz operation
Reference no. 2553.5-10 also available in 60 HzPumpDrive • Hyamaster • Amacontrol • Switchgears • LevelControl
Submersible motor pump DN 80 to DN 200
Automation possible
36
S u b m e r s i b l e p u m p s i n d i s c h a r g e t u b e s
Design: Wet-installed submersible motor pump with mixed flow impeller, single-stage, for installation in discharge tubes. ATEX-compliant version available.
Applications: Handling of water without stringy substances in irrigation and drainage pumping systems, general water supply systems, water pollution and flood control systems.
Amacan S
DN __________ 650 - 1300 Q [m3/h] _____ max. 10800H [m] ___________ max. 40T [°C] _________ max. +30n [min-1] ______ max. 1450Data for 50 Hz operation
Reference no. 1589.5-10 also available in 60 HzHyamaster • Amacontrol
Submersible motor pump with mixed flow impeller
Design: Wet-installed, submersible motor pump with axial propeller in ECB designfor installation in discharge tubes, single-stage, single-entry. ATEX-compliant version available.
Applications: Irrigation and drainage pumping stations, stormwater pumping stations, handling of raw and clean water in water and effluent treatment plants, of cooling water in power stations and industrial plants, industrial water supply systems, water pollution and flood control systems, aquaculture.
Amacan P
DN __________ 500 - 1500Q [m3/h] _____ max. 25200H [m] ___________ max. 12T [°C] _________ max. +40n [min-1] ______ max. 1450Data for 50 Hz operation
Reference no. 1580.5-10 also available in 60 HzHyamaster • Amacontrol
Submersible motor pump with axial propeller
Design: Wet-installed submersible motor pump with non-clogging impeller, single-stage, single-entry, for installation in discharge tubes. ATEX-compliant version available.
Applications: Handling of pre-cleaned, chemically neutral waste water, industrial effluents and sewage, fluids not containing any stringy substances pre-treated by screens and sills, as waste water, mixed water and activated sludge pump in effluent treatment plants, irrigation and drainage pumping systems.
Amacan K
DN __________ 700 - 1400 Q [m3/h] ______ max. 7200H [m] ___________ max. 30T [°C] _________ max. +40n [min-1] _______ max. 980Data for 50 Hz operation
Reference no. 1579.5-10 also available in 60 HzHyamaster • Amacontrol
Submersible motor pump with non-clogging impeller
M i x e r s / a g i t a t o r s / t a n k c l e a n i n g u n i t s
Design: Horizontal submersible mixer with self-cleaning ECB propeller, close- coupled design, direct drive or with gear unit. ATEX-compliant version available.
Applications: Handling of municipal and industrial waste water and sludges, also in environmental engineering (biogas plants, etc.).
Amamix
Propeller ø [mm] _ 200 - 600Install. depth [m] _ max. 30T [°C] _________ max. +40n [min-1] ______ max. 1400Data for 50 Hz operation
Reference no. 1592.551-10 / 1592.552-10 also available in 60 Hz
Submersible mixer
Automation possible
37Automation possible
M i x e r s / a g i t a t o r s / t a n k c l e a n i n g u n i t s
Design: Horizontal submersible agitator with self-cleaning ECB propeller, close- coupled design, equipped with coaxial spur gear. ATEX-compliant version available.
Applications: In environmental engineering, particulary for circulating, keeping in suspension and inducing flow in municipal and industrial waste water and sludges; in nitrification and denitrification tanks, activated sludge tanks, mixing tanks, final storage tanks, biological phosphate elimination tanks, flocculation tanks and in biogas applications.
Amaprop
Propeller ø [mm] _ 1000 - 2500Install. depth [m] _ max. 30T [°C] _________ max. +40n [min-1] _______ max. 109
Reference no. 1592.505-10
Submersible agitator
Design: Stationary or portable unit with horizontal or vertical submersible motor propulsive jet pump with non-clogging free-flow impeller. Motor rating 5.5 to 27 kW. Available variants: Amajet, SewerAmajet, SwingAmajet, MultiAmajet.
Applications: Cleaning of stormwater tanks and storage sewers.
Amajet
DN ____________ 100 - 150 Q [m3/h] _______ max. 195T [°C] _________ max. +40n [min-1] ______ max. 1450
Reference no. 1574.5-10
Cleaning system
Design: Wet-installed, horizontal propeller pump with submersible motor, equipped with spur gear or direct drive, ECB propeller with 3 rigid, fibre-repellent blades, bolt-free connection to the discharge pipe. ATEX-compliant version available.
Applications: Recirculation of activated sludge in waste water treatment systems.
Amaline
DN ____________ 300 - 800 Q [m3/h] ______ max. 5400H [m] ____________ max. 2T [°C] _________ max. +40n [min-1] _______ max. 960
Reference no. 1594.5-10
Submersible motor recirculation pump
P u m p s f o r s o l i d s - l a d e n f l u i d s
Design: Horizontal or vertical volute casing pump with free-flow (F), single vane (E), multi-vane (K) and diagonal single vane (D) impellers, discharge flange to DIN and ANSI standards. ATEX-compliant version available.
Applications: Handling of sewage and all types of waste water in waste water management and industry.
Sewatec / Sewabloc
DN _____________ 50 - 700 Q [m3/h] _____ 60 - 10000H [m] ___________ max. 95p [bar] __________ max. 10T [°C] _________ max. +70n [min-1] ______ max. 2900Data for 50 Hz operation
Reference no. 2580.5-10/2580.45-10/2580.35-10 also available in 60 HzHyamaster • PumpDrive • LevelControl
Dry-installed volute casing pump
38
Design: Horizontal, radially split volute casing pump in back pull-out or close-coupled design, single-stage, single-entry, available with various impeller types:non-clogging impeller, open multi-vane impeller, free-flow impeller. ATEX-compliant version available.
Applications: Handling of pre-treated sewage, waste water, all types of slurries without stringy substances and pulps up to 5 % bone dry.
KWP / KWP-Bloc
DN __ 40 - 900 (max. 1000)Q [m3/h] _____ max. 15000 ______________ (18000)H [m] __________ max. 100p [bar] __________ max. 10T [°C] _ +120 (max. +280)n [min-1] ______ max. 2900Data for 50 Hz operation
Reference no. 2361.5-10/2362.5-10/2361.450-10/2361.453-10/2361.460-10 also available in 60 HzHyamaster
Non-clogging impeller centrifugal pump / close-coupled unit
P u m p s f o r s o l i d s - l a d e n f l u i d s
Automation possible
S l u r r y p u m p s
Design: Patented design incorporates state-of-the art hydraulic and wear tech-nologies for heavy-duty, high-pressure applications. The pump shell is designed to reduce stresses that can cause a structural failure during a pressure surge.
Applications: Ideal for ore and tailings transport to minimize the effect of sudden pressure spikes.
WBC
Q [m3/h] _____ max. 13600H [m] ___________ max. 80p [bar] __________ max. 40T [°C] ________ max. +120
Slurry pump
Design: Premium design hard iron pumps for long wear life pumping severe slurries. The basic, single-wall construction and heavy section, hard metal wet end combined with the cartridge bearing assembly provides maximum reliability and ease of maintenance.
Applications: Pumps are widely used in ore transport, mill discharge, cyclone feed, tailings and plant process.
LSA-S
Q [m3/h] _____ max. 14000H [m] ___________ max. 90p [bar] __________ max. 16T [°C] ________ max. +120
Slurry pump
Design: The hydraulic wet end consists of three components: a shell or casing, an impeller and a suction plate/liner to permit easy removal for maintenance and inspections.
Applications: Reliable pumps for high discharge head, mildly corrosive slurries and a wide range of particle sizes. Used in mineral processing, mine dewatering, ash and tailings.
LCC-M
Q [m3/h] ______ max. 3865H [m] ___________ max. 90p [bar] __________ max. 16T [°C] ________ max. +120
Slurry pump
39
Design: Interchangeable rubber and metal design allows best material choice for any application. Easy wet end change can adapt existing pumps to new applications.
Applications: Pumps are suitable for moderate discharge heads, fine particles and highly corrosive slurries.
LCC-R
Q [m3/h] ______ max. 3865H [m] ___________ max. 90p [bar] __________ max. 16T [°C] ________ max. +100
Slurry pump
S l u r r y p u m p s
Design: A high-pressure design, these pumps are constructed as horizontal, end suction centrifugal pumps to give maximum resistance to wear while simplifying maintenance. The conventional single-wall design transfers stress loads to non-wearing side plates in high-pressure applications.
Applications: Features high head and high flow rates for hydrotransport, tailings, dredging, pipeline booster stations and other severe duties.
TBC
Q [m3/h] _____ max. 18200H [m] ___________ max. 90p [bar] __________ max. 55T [°C] ________ max. +120
Slurry pump
Design: High-flow/low-head hard metal pumps with a single-wall shell design. High-efficiency impeller. Suction-side liner is equipped with integrated mounting plates.
Applications: Absorber recirculation and ancillary process pumps.
FGD
Q [m3/h] _____ max. 22700H [m] ___________ max. 45p [bar] __________ max. 17T [°C] ________ max. +120
Slurry pump
Design: Extra heavy-duty pumps with a high-grade rubber lining for hard wearing applications. The key to the LSR‘s success is its endurance.
Applications: Designed for heavy-duty mill circuit and fine grind slurries; specific-ally copper, iron ore, gold, aggregate and other abrasive applications.
LSR
Q [m3/h] ______ max. 9000H [m] ___________ max. 60p [bar] __________ max. 14T [°C] ________ max. +120
Slurry pump
Design: Vertical cantilever, rugged hard metal sump pump with bottom suction and no submerged bearings. Replaceable wet end parts in metal alloys with a durable mechanical end.
Applications: Ideal for industrial process pumping, tailings disposal in mining and pit use.
LCV
Q [m3/h] ______ max. 1360H [m] ___________ max. 38p [bar] __________ max. 14T [°C] ________ max. +120
Slurry pump
40
S l u r r y p u m p s
Design: Horizontal, end suction, modified volute casing pump includes 3 vane open design impeller for large solids passage.
Applications: High-performance, low maintenance slurry pump recommended for coarse or fine particles from solids-laden waste water to aggressive slurries of an abrasive and/or corrosive nature.
Mega
Q [m3/h] ________ max. 45H [m] ___________ max. 30p [bar] __________ max. 24T [°C] ________ max. +120
Slurry pump
Design: Best suited for high-flow, high-head pumping where high production requires the reduction in the number of pumps.
Applications: Ideal for pipeline booster stations and severe mining duties. Also, as booster or main hull pump on cutter suction dredges.
HHD
Q [m3/h] _____ max. 14400H [m] ___________ max. 90p [bar] __________ max. 29T [°C] ________ max. +120
Slurry pump
Design: Designed to provide high flow/medium head with high efficiency for high volume transportation in long pipelines.
Applications: Ideal for pipeline booster stations and severe mining duties. Also for hopper dredges or as main pump on cutter dredges.
MHD
Q [m3/h] _____ max. 32000H [m] ___________ max. 80p [bar] __________ max. 28T [°C] ________ max. +120
Slurry pump
Design: High-flow/low-head design with balanced NPSHR and sphere passage for high volume transportation over short distance.
Applications: Ideal for sand & gravel, severe mining, dredge ladder and booster pumps.
LHD
Q [m3/h] _____ max. 21600H [m] ___________ max. 65p [bar] __________ max. 17T [°C] ________ max. +120
Slurry pump
Design: The latest technology from GIW provides superior wear life and increased up-time handling your most aggressive slurry applications.
Applications: Designed for SAG and ball mill discharge duties as well as cyclone feed and screen feed applications in ore mining.
MDX
Q [m3/h] _____ max. 14000H [m] ___________ max. 90p [bar] __________ max. 16T [°C] ________ max. +120
Slurry pump
41
S l u r r y p u m p s
Design: Vertical cantilever, rugged hard metal sump pumps with top and bottom suction, not submerged bearings. Replaceable wet end parts in metal alloys with a durable mechanical end.
Applications: Abrasive slurries, dewatering, floor clean up, and process transfer.
ZW
Q [m3/h] _______ max. 400H [m] ___________ max. 35p [bar] __________ max. 10T [°C] ________ max. +120
Slurry pump
S e l f - p r i m i n g p u m p s
Design: Horizontal, long-coupled, self-priming volute casing pump in back pull-outdesign, single-stage, with open multi-vane impeller. ATEX-compliant version available.
Applications: Handling of pure, contaminated or aggressive liquids not containing abrasive substances and / or solids.
Etaprime L
DN _____________ 25 - 125Q [m3/h] _______ max. 180H [m] ___________ max. 85p [bar] __________ max. 10T [°C] _________ max. +90Data for 50 Hz operation
Self-priming pump for pure or contaminated liquids
Reference no. 2745.5-10 also available in 60 Hz
Design: Horizontal, self-priming volute casing pump, single-stage, with open multi-vane impeller, in close-coupled design, with common pump and motor shaft (B) orrigidly connected (BN). ATEX-compliant version available.
Applications: Handling of pure, contaminated or aggressive liquids not containing abrasive substances and / or solids.
Etaprime B / BN
DN _____________ 25 - 100Q [m3/h] _______ max. 130H [m] ___________ max. 72p [bar] __________ max. 10T [°C] _________ max. +90Data for 50 Hz operation
Reference no. 2746.5-10 also available in 60 Hz
Self-priming close-coupled pump for pure or contaminated liquids
42
S u b m e r s i b l e b o r e h o l e p u m p s
Design: Multistage centrifugal pump in ring-section design, for vertical or horizontal installation, impellers made of plastic (S 100D) or stainless steel (UPA 100C) for well diameters of 100 mm (4 inches) and above, available with single-phase a.c. motor or three-phase motor with motor lead.
Applications: Domestic water supply, irrigation and spray irrigation systems, lower-ing of ground water levels, fire-fighting systems, cooling circuits, fountains, pressure boosting and air-conditioning systems.
S 100D / UPA 100C
DN _________________ 100Q [m3/h] ________ max. 16H [m] __________ max. 400T [°C] _________ max. +30Data for 50 Hz operation
Reference no. 3400.5-10 also available in 60 HzSwitchgears • Cervomatic
Submersible borehole pump
Design: Single-stage or multistage centrifugal pump in ring-section design, for vertical or horizontal installation, completely made of stainless steel, for well diam-eters of 150 mm (6 inches) and above.
Applications: Handling of clean or slightly contaminated water, irrigation and drainage, spray irrigation, industrial and municipal water supply, maintaining / lowering of groundwater levels, fire-fighting systems, drinking, raw and service water supply, pressure boosting.
UPA 150C
DN _________________ 150Q [m3/h] ________ max. 79H [m] __________ max. 570T [°C] _________ max. +50Data for 50 Hz operation
Reference no. 3400.52-10 also available in 60 HzHyamaster • PumpDrive
Submersible borehole pump
Design: Single- or multistage, single-entry centrifugal pump in ring-section design for vertical or horizontal installation. Non-return valve or connection branch on option. Mixed flow hydraulic systems available with reduced impeller diameters.
Applications: Handling of clean or slightly contaminated water in general water supply, irrigation and spray irrigation systems, maintaining / lowering of ground water levels, in mines, fire-fighting systems, fountains, etc.
UPA 300, 350
DN ____________ 300 - 350Q [m3/h] _______ max. 840H [m] __________ max. 480T [°C] _________ max. +50Data for 50 Hz operation
Reference no. 3400.5-10 also available in 60 HzHyamaster
Submersible borehole pump
Design: Single-stage or multistage single-entry centrifugal pump in ring-section design for vertical or horizontal installation. Available with non-return valve or con-nection branch.
Applications: Handling of clean or slightly contaminated water in general water supply, irrigation and spray irrigation systems, maintaining / lowering of ground water levels, fountains, pressure boosting systems, in mines, fire-fighting systems, emergency water supply systems, etc.
UPA 200, 200B, 250C
DN ____________ 200 - 250Q [m3/h] _______ max. 330H [m] __________ max. 460T [°C] _________ max. +50Data for 50 Hz operation
Reference no. 3400.5-10 also available in 60 HzHyamaster
Submersible borehole pump
Design: Single- or multistage, single-entry (BSX-BSF) or double-entry (UPZ) centrifugal pump in ring-section design for vertical or horizontal installation.
Applications: Handling of clean or slightly contaminated water, maintaining / lowering of ground water levels, in mines.
UPZ, BSX-BSF
DN _______________ > 350Q [m3/h] ______ max. 2200H [m] _________ max. 1500T [°C] _________ max. +50Data for 50 Hz operation
Reference no. 3470.021-10 also available in 60 Hz
Submersible borehole pump
Automation possible
43
Design: Multistage, vertical high-pressure centrifugal pump in ring-section design with suction and discharge nozzles of identical nominal diameters arranged opposite to each other (in-line design), close-coupled and motor-mounted variable speed system.
Applications: Spray irrigation, irrigation, washing, water treatment, fire-fighting and pressure boosting systems, hot water and cooling water recirculation, boiler feed systems, etc.
Movitec PumpDrive
DN _____________ 25 - 100Q [m3/h] _______ max. 113H [m] __________ max. 401p [bar] __________ max. 40T [°C] ________ max. +140n [min-1] ______ max. 2900
Reference no. 1798.5-10 + 4070.5-10 also suitable for 60 Hz operation
High-pressure in-line pump with motor-mounted variable speed system
Design: Multistage horizontal or vertical centrifugal pump in ring-section design, long-coupled and close-coupled variant, with axial or radial suction nozzle, cast radial impellers. ATEX-compliant version available.
Applications: Water and drinking water supply systems, general industry, pressure boosting systems, irrigation systems, in power stations, heating, filter, fire-fighting, reverse osmosis and washing plants, snow guns, etc.
Multitec
DN _____________ 32 - 150Q [m3/h] _______ max. 850H [m] _____ max. 630 (800)p [bar] ______ max. 63 (80)T [°C] ______ -10 to +200n [min-1] ______ max. 4000Data for 50 Hz operation
Reference no. 1777.5-10 available in 50 Hz and 60 HzHyamaster
High-pressure pump in ring-section design
Design: Multistage horizontal or vertical centrifugal pump in ring-section design, long-coupled and close-coupled variant, with axial or radial suction nozzle, cast radial impellers and motor-mounted variable speed system.
Applications: Water and drinking water supply systems, general industry, pressure boosting systems, irrigation systems, in power stations, heating, filter, fire-fighting, reverse osmosis and washing plants, snow guns, etc.
Multitec PumpDrive
DN _____________ 32 - 125Q [m3/h] _______ max. 180H [m] __________ max. 630p [bar] __________ max. 63T [°C] ________ max. +110n [min-1] ______ max. 4000
Reference no. 1777.5-10 + 4070.5-10 also suitable for 60 Hz operation
High-pressure pump in ring-section design with motor-mounted variable speed system
Design: Multistage, vertical high-pressure centrifugal pump in ring-section designwith suction and discharge nozzles of identical nominal diameters arranged oppos-ite to each other (in-line design), close-coupled. ATEX-compliant version available.
Applications: Spray irrigation, irrigation, washing, water treatment, fire-fighting and pressure boosting systems, hot water and cooling water recirculation, boiler feed systems, etc.
Movitec V / LHS / VS / VC
DN _____________ 25 - 100Q [m3/h] _______ max. 113H [m] __________ max. 401p [bar] __________ max. 40T [°C] ________ max. +140n [min-1] ______ max. 2900Data for 50 Hz operation
Reference no. 1798.5-10 also available in 60 HzPumpMeter • Hyamaster
High-pressure in-line pump
H i g h - p r e s s u r e p u m p s , f i x e d / v a r i a b l e s p e e d
Automation possibleFactory-automated
PumpMeter
44
A x i a l l y s p l i t p u m p s
Design: Single-stage, axially split volute casing pump for horizontal or vertical installation with double-entry radial impeller, mating flanges to DIN, ISO, BS or ANSI.
Applications: Handling of raw, pure and service water as well as seawater in water treatment plants, irrigation and drainage pumping stations, in power stations, fire-fighting systems, shipbuilding and the petrochemical industry.
RDLO
DN ____________ 350 - 700Q [m3/h] _____ max. 10000H [m] __________ max. 240p [bar] __________ max. 25T [°C] _________ max. +70n [min-1] ______ max. 1450Data for 50 Hz operation,higher values available upon request
Doku-Nr. 1385.51-10/1387.5 -10 also available in 60 HzHyamaster
Axially split volute casing pump DN 350 - 700
H y g i e n i c p u m p s f o r t h e f o o d , b e v e r a g e a n d p h a r m a c e u t i c a l
i n d u s t r i e s
Design: Maintenance-friendly annular casing pump, close-coupled with stand-ardised motor, all wetted components made of 316L stainless steel. Certified by the TNO Nutrition and Food Research Institute to EHEDG standards for processing food products.
Applications: Hygienic handling of fluids in the food, beverage and pharmaceuti-cal industries as well as in the chemical industry.
Vitachrom
DN _____________ 50 - 125Q [m3/h] _______ max. 340H [m] __________ max. 100p [bar] __________ max. 12T [°C] ________ max. +110Data for 50 Hz operation
Reference no. 1966.5-10 also available in 60 HzHyamaster • PumpDrive
Rolled steel centrifugal pump
Design: Single-stage, axially split volute casing pump for horizontal or vertical installation, with double-entry radial impeller, mating flanges to DIN, ISO, BS or ANSI.
Applications: Handling of raw, pure and service water as well as seawater in water treatment plants, irrigation and drainage pumping stations, power stations, fire-fighting systems, shipbuilding and the petrochemical industry.
Omega
DN _____________ 80 - 350Q [m3/h] ______ max. 2880H [m] __________ max. 170p [bar] __________ max. 25T [°C] _________ max. +70n [min-1] ______ max. 2900Data for 50 Hz operation,higher values available upon request
Reference no. 1384.5-10 also available in 60 HzHyamaster
Axially split volute casing pump DN 80 - 350
Automation possible
Design: Maintenance-friendly volute casing pump with standardised motor, all wetted components made of 316L stainless steel. Hygienic design for the highest requirements on cleanability (CIP/SIP-compatible), certified by the TNO Nutrition and Food Research Institute to EHEDG standards (Vitacast E).
Applications: Hygienic handling of fluids in the food, beverage and pharmaceuti-cal industries as well as in the chemical industry.
Vitacast / Vitacast E
DN _____________ 25 - 150Q [m3/h] _______ max. 560H [m] __________ max. 100p [bar] __________ max. 10T [°C] ________ max. +100Data for 50 Hz operation,other values available upon request
Reference no. 1969.51 / 1969.52 also available in 60 HzPumpDrive
Investment cast centrifugal pump
45Automation possible
H y g i e n i c p u m p s f o r t h e f o o d , b e v e r a g e a n d p h a r m a c e u t i c a l
i n d u s t r i e s
Design: Maintenance-friendly, self-priming side channel pump in close-coupled design with standardised motor, all wetted components made of 316L stainless steel. Hygienic design for the highest requirements on cleanability (CIP/SIP-compatible).
Applications: Hygienic handling of fluids in the food, beverage and pharmaceuti-cal industries as well as in the chemical industry.
Vitaprime
DN ______________ 40 - 80Q [m3/h] ________ max. 55H [m] ___________ max. 43p [bar] ___________ max. 4T [°C] ________ max. +100Data for 50 Hz operation,other values available upon request
Reference no. 1969.54 also available in 60 Hz
Self-priming centrifugal pump
Design: Sturdy rotary lobe pump in hygienic design, bi-directional operation pos-sible, horizontal and vertical orientation of connections. Hygienic design, all wetted components made of 316L stainless steel; various rotor types and process connec-tions available. Pump set with geared motor.
Applications: Hygienic and gentle handling of sensitive or high-viscosity fluids in the food, beverage and pharmaceutical industries as well as in the chemical indus-try and general process engineering.
VitalobeDN ________ 25 - 200 (1“ - 8“)Q [m3/h] ____________ max. 300H [m] ______________ max. 200p [bar] ______________ max. 30T [°C] ___________ -40 to +200Viscosity [cP] ______ ≤ 3000000Volume displaced _____________ [litres per revolution] __ max. 10,5Data for 50 Hz operation,other values available upon request
Reference no. 1969.53 also available in 60 Hz
Rotary lobe pump
Design: Multistage centrifugal pump in close-coupled design for vertical or horizontal installation. All wetted components made of 316 stainless steel.
Applications: Processes in the food and beverage industry as well as in the chemical industry with moderate hygienic requirements.
Vitastage
Q [m3/h] ________ max. 40H [m] __________ max. 150p [bar] __________ max. 16T [°C] ________ max. +100Data for 50 Hz operation,other values available upon request
Reference no. 1969.55 also available in 60 Hz
Multistage centrifugal pump
PumpDrive
PumpDrive
P u m p s f o r p o w e r s t a t i o n c o n v e n t i o n a l i s l a n d s
Design: Horizontal, high-pressure barrel-type pump with radial impellers, single- and double-entry, multistage, with flanges / weld end nozzles to DIN and ANSI.
Applications: Handling of feed water and condensate in power stations and industrial facilities, generation of pressurized water for bark peeling machines and descaling equipment.
CHTA / CHTC / CHTD
DN ____________ 100 - 500Q [m3/h] ______ max. 3700H [m] _________ max. 5300p [bar] _________ max. 560T [°C] ________ max. +210n [min-1] ______ max. 6750Data for 50 Hz operation,higher values available upon request
Boiler feed pump
Reference no. 1860.1-10 also available in 60 Hz
46
Design: Horizontal, radially split, product-lubricated, multistage ring-section pump with radial impellers, axial and radial single-entry inlet.
Applications: Handling of feed water in power stations, boiler feed water and condensate in industrial facilities.
HGM
DN _____________ 25 - 100Q [m3/h] _______ max. 274H [m] _________ max. 1400p [bar] _________ max. 140T [°C] ________ max. +160n [min-1] ______ max. 3600Data for 50 Hz operation,higher values available upon request
Boiler feed pump
Reference no. 1856.02-10 also available in 60 Hz
Design: Horizontal, radially split, single-stage, double-entry boiler feed booster pump (booster system) with single or double cast steel volute casing.
Applications: Handling of feed water in power stations and industrial facilities.
YNK / KRHA
DN ____________ 125 - 600Q [m3/h] ______ max. 3700H [m] __________ max. 280p [bar] __________ max. 40T [°C] ________ max. +210n [min-1] ______ max. 1800Data for 50 Hz operation,higher values available upon request
Boiler feed booster pump
Reference no. 1130.5-10 also available in 60 Hz
Design: Horizontal, radially split, multistage ring-section pump with radial impellers, single- or double-entry.
Applications: Handling of feed water and condensate in power stations and industrial facilities, generation of pressurized water for bark peeling machines, descaling equipment, snow guns, etc.
HGB / HGC / HGD
DN _____________ 40 - 400Q [m3/h] ______ max. 2300H [m] _________ max. 5300p [bar] _________ max. 560T [°C] ________ max. +210n [min-1] ______ max. 7000Data for 50 Hz operation,higher values available upon request
Boiler feed pump
Reference no. 1850.02-10 also available in 60 Hz
Design: Horizontal, high-pressure barrel-type pump with radial impellers, single- and double-entry, multistage, with flanges / weld end nozzles to DIN, API 610 and ANSI.
Applications: In refineries, in the petrochemical industry and in steam generation plants.
CHTR
DN ______________ 50 - 150 Q [m3/h] _______ max. 900H [m] _________ max. 2500p [bar] _________ max. 250T [°C] ________ max. +400n [min-1] ______ max. 7000Data for 50 Hz operation,higher values available upon request
Boiler feed pump
Reference no. 2701-10 also available in 60 Hz
P u m p s f o r p o w e r s t a t i o n c o n v e n t i o n a l i s l a n d s
Design: Horizontal, single-stage, double-entry feed water pump, cast and forged variant.
Applications: Handling of feed water in steam generation systems of nuclear power stations.
RHD
DN ____________ 250 - 400Q [m3/h] ______ max. 6500H [m] _________ max. 1000p [bar] _________ max. 150T [°C] ________ max. +210n [min-1] ______ max. 6500Data for 50 Hz operation,higher values available upon request
Feed water pump
also available in 60 Hz
47
P u m p s f o r p o w e r s t a t i o n c o n v e n t i o n a l i s l a n d s
Design: Vertical spherical casing pump, radial impellers, single-entry, single- to three-stage. Suitable for very high inlet pressures and temperatures. Integrated wet winding motor to VDE. Product-lubricated bearings, no need for oil supply systems. Design to TRD or ASME.
Applications: Hot water recirculation in forced-circulation, forced-flow and combined-circulation boilers for very high pressures.
LUV / LUVA
DN ____________ 100 - 550Q [m3/h] ______ max. 7000H [m] __________ max. 275p [bar] _________ max. 320T [°C] ________ max. +420n [min-1] ______ max. 3600Data for 50 Hz operation,higher values available upon request
Boiler recirculation pump
Reference no. 0361.033-10 also available in 60 Hz
Design: Vertical, multistage, can-type ring-section pump with radial and mixed flow impellers. Single- and double-entry suction impellers, flanges to DIN or ANSI. The can is arranged in a pit below the installation floor. The pump is connected with the structure by means of a baseplate.
Applications: Handling of condensate in power stations and energy systems.
WKT / WKTA / WKTB
DN _____________ 40 - 300Q [m3/h] ______ max. 1800H [m] __________ max. 340p [bar] __________ max. 40T [°C] ________ max. +100n [min-1] ______ max. 1800Data for 50 Hz operation,higher values available upon request
Condensate pump
Reference no. 0361.033-10 also available in 60 Hz
Design: Vertical tubular casing pump with open mixed flow impeller (SEZ), mixed flow propeller (PHZ) or axial propeller (PNZ). Pump inlet with bellmouth or suction elbow, pull-out design available, discharge nozzle arranged above or below floor, flanges to DIN or ANSI standards available.
Applications: Handling of raw, pure, service and cooling water in industry, water supply systems, in power stations and seawater desalination plants.
SEZ / SEZT / PHZ / PNZ
Q [m3/s] ________ max. 22H [m] __________ max. 100T [°C] _________ max. +40n [min-1] _______ max. 980Data for 50 Hz operation,higher values available upon request
Cooling water pump
Reference no. 1471.02-10 also available in 60 Hz
Design: Vertical tubular casing pump with mixed flow impeller (SNW) or axial propeller (PNW), single-stage, with maintenance-free Residur shaft bearings, discharge nozzle arranged above or below floor.
Applications: Irrigation and drainage systems, stormwater pumping stations, hand ling of raw and pure water, water supply systems, handling of cooling water.
SNW / PNW
DN ____________ 350 - 800Q [m3/h] ______ max. 9000H [m] ___________ max. 50p [bar] __________ max. 10T [°C] _________ max. +60n [min-1] ______ max. 1500Data for 50 Hz operation,higher values available upon request
Cooling water pump
Reference no. 1481.5-10/1591.5-10 also available in 60 Hz
Design: Long-coupled, single-stage volute casing pump in back pull-out design.
Applications: Drainage, irrigation and water supply systems, handling of conden-sate, cooling water, service water, etc.
SPY
DN __________ 350 - 1200Q [m3/h] _____ max. 21600H [m] ___________ max. 50p [bar] __________ max. 10T [°C] ________ max. +105n [min-1] ______ max. 1480Data for 50 Hz operation,higher values available upon request
Cooling water pump
Reference no. 2384.51-10 also available in 60 Hz
48
P u m p s f o r p o w e r s t a t i o n n u c l e a r i s l a n d s
Design: Vertical, single-stage reactor coolant pump with forged annular casing plated on the inside, with diffuser, either with own pump thrust bearing or supported by motor bearing.
Applications: Reactor coolant recirculation in nuclear power stations (PWR).
RER
DN ____________ max. 800Q [m3/h] _____ max. 40000H [m] __________ max. 140p [bar] _________ max. 175T [°C] ________ max. +350n [min-1] ______ max. 1800Data for 50 Hz operation,higher values available upon request
Reactor coolant pump
also available in 60 Hz
Design: Vertical, single-stage reactor coolant pump, with cast double volute casing, supported by motor bearing.
Applications: Reactor coolant recirculation in nuclear power stations (PWR, PHWR).
RSR
DN ____________ max. 600Q [m3/h] ______ max. 9000H [m] __________ max. 215p [bar] _________ max. 125T [°C] ________ max. +310n [min-1] _______ max. 1800Data for 50 Hz operation,higher values available upon request
Reactor coolant pump
Design: Vertical pump set integrated in the reactor pressure vessel, glandless pump with leak-free, low-maintenance wet winding motor.
Applications: Reactor coolant recirculation in boiling water reactors (BWR).
PSR
DN ____________ max. 600Q [m3/h] ______ max. 9000H [m] ___________ max. 45p [bar] __________ max. 75T [°C] ________ max. +300n [min-1] ______ max. 2000Data for 50 Hz operation,higher values available upon request
Reactor internal pump
also available in 60 Hz
Design: Vertical pump with integrated motor, single-entry, one to three stages. Suitable for very high inlet pressures and temperatures. Integrated wet winding motor to VDE. Product-lubricated bearings, no need for oil supply systems. Design to ASME Section 3, KTA, etc.
Applications: As reactor water clean-up pump in boiling water reactors, reactor coolant pump in boiling water and pressurized water reactors, and as recirculation pump in test facilities.
LUV - Nuclear
DN _____________ 40 - 600Q [m3/h] ______ max. 7000H [m] __________ max. 300p [bar] _________ max. 320T [°C] ________ max. +430Data for 50 Hz operation,higher values available upon request
Reactor coolant / reactor water clean-up pump
also available in 60 Hz
Design: Horizontal, multistage barrel pull-out pump.
Applications: Core flooding, emergency cooling and residual heat removal systems, volume control systems, high-pressure charging, control rod drive systems, high- and medium-pressure safety injection systems, auxiliary feed water systems, start-up and shutdown feed water systems.
RHM
DN ____________ max. 150Q [m3/h] _______ max. 300H [m] _________ max. 2100p [bar] _________ max. 220T [°C] ________ max. +180n [min-1] ______ max. 8000Data for 50 Hz operation,higher values available upon request
Pump for safety-related and auxiliary systems
also available in 60 Hz
49
Design: Vertical, multistage barrel pull-out pump.
Applications: Core flooding, emergency cooling and residual heat removal systems, volume control systems, high-pressure safety injection systems.
RVM
DN _____________ max. 85Q [m3/h] ________ max. 50H [m] _________ max. 2000p [bar] _________ max. 200T [°C] ________ max. +100n [min-1] ______ max. 6000Data for 50 Hz operation,higher values available upon request
Pump for safety-related and auxiliary systems
also available in 60 Hz
Design: Horizontal or vertical annular casing pump with forged pressure boundary and diffuser.
Applications: Core flooding, emergency cooling and residual heat removal systems, ancillary systems, acid feed systems and low- pressure feed systems.
RHR / RVR
DN ____________ max. 500Q [m3/h] ______ max. 6000H [m] __________ max. 190p [bar] __________ max. 63T [°C] ________ max. +200n [min-1] ______ max. 3600Data for 50 Hz operation
Pump for safety-related and auxiliary systems
also available in 60 Hz
P u m p s f o r p o w e r s t a t i o n n u c l e a r i s l a n d s
Design: Vertical, single-stage reactor coolant pump. Seal-less design with inte-grated wet winding motor and integrated flywheel. Product-lubricated bearings, no oil supply systems required.
Applications: Main coolant circulation in third-generation nuclear power stations.
RUV
DN ____________ max. 710Q [m3/h] _____ max. 22000H [m] __________ max. 111p [bar] _________ max. 155T [°C] ________ max. +350n [min-1] ______ max. 1800higher values available upon request
Reactor coolant pump
available in 50 Hz and 60 Hz
50
P u m p s a n d p r e s s u r e e x c h a n g e r s f o r s e a w a t e r d e s a l i n a t i o n
b y r e v e r s e o s m s i s
Description: Pressure exchanger specially developed for use in RO seawater desalination systems, in duplex stainless steel (standard) or super duplex stainless steel (on request).
SalTec DT
Q [m3/h] _______ max. 280p [bar] __________ max. 80T [°C] _________ max. +40
Pressure exchanger
Reference no. 1858.1-10
Design: Hydraulic system for pressure boosting and energy recovery in reverse osmosis processes for seawater desalination.
Components: SalTec® DT pressure exchanger, HGM-RO high-pressure pump, RPH-RO booster pump and control unit.
Applications: Seawater desalination by reverse osmosis.
SalTec System
Q [m3/day] ______ ≥ 10000p [bar] __________ max. 80T [°C] _________ max. +40
Hydraulic system
Reference no. 1858.11-10
Design: Horizontal, radially-split, product-lubricated, multistage ring-section pump with radial impellers and plain bearings. Axial and radial single-entry inlet. Duplex stainless steel variant also suitable for chilled water applications.
Applications: High-pressure pump for RO seawater desalination systems.
HGM-RO
DN _____________ 65 - 250 Q [m3/h] ______ max. 1500H [m] __________ max. 950p [bar] _________ max. 120T [°C] _________ max. +40n [min-1] ______ max. 3600Data for 50 Hz operation, higher values available upon request
High-pressure pump
Reference no. 1582.12-10 also available in 60 Hz
Design: Horizontal, multistage pump in ring-section design. Axial suction nozzle, discharge nozzle can be turned in steps of 90°. Closed radial impellers. In duplex or super-duplex stainless steel.
Applications: High-pressure pump for RO seawater desalination systems.
Multitec-RO
DN _____________ 50 - 150Q [m3/h] _______ max. 850H [m] _________ max. 1000p [bar] _________ max. 100T [°C] _________ max. +40n [min-1] _______ max. 4000Data for 50 Hz operation
High-pressure pump
Reference no. 1777.13-10 available in 50 Hz and 60 Hz
Design: Horizontal, radially split volute casing pump, dry-installed, made of duplex stainless steel (standard) or super duplex stainless steel (on request).
Applications: Booster pump for RO seawater desalination systems.
RPH-RO
DN _____________ 25 - 400Q [m3/h] ______ max. 4150H [m] __________ max. 270p [bar] _________ max. 104T [°C] _________ max. +50Data for 50 Hz operation
Booster pump
also available in 60 Hz
Automation possibleFactory-automated
Hyamaster • PumpDrive
51
C o n t r o l u n i t s
Design: Single-pump control system for starting, stopping and monitoring pumps.
Applications: Water supply systems, in combination with pumps like Multi Eco, Multichrom S, Ixo, S 100D, etc.
Controlmatic E.2
No. of pumps _____ max. 1 Voltage [V] _______ 1∼230
Reference no. 5125.1785-10
Automatic control unit
Design: Single-pump control unit for pressure-controlled starting and either pressure-controlled or flow-controlled stopping as well as monitoring pumps.
Applications: In water supply systems using, for example, Multi Eco, Ixo, S 100D and UPA 150C.
Cervomatic EDP.2
No. of pumps _____ max. 1 Voltage [V] __ 1∼230 / 3∼400
Reference no. 5125.178-10
Automatic control unit
Design: Level control unit for controlling up to two pumps. Direct starting up to 4 kW, star-delta starting up to 22 kW.
Applications: Tank drainage via float switches, pneumatic or bubbler control in building services and waste water applications.
LevelControl
No. of pumps ____ max. 2[kW] ___________ max. 22Voltage [V] _____ 230 / 400higher values available upon request
Reference no. 4040.5-10, 4041.5-10
Level control unit
Design: Single-pump control unit for submersible borehole pumps, submersible motor pumps and dry-installed pumps.
Applications: Water supply systems, in combination with pumps like S 100D, UPA 150S, etc.
UPA Control
No. of pumps _____ max. 1 [kW] _________________ 3Voltage [V] _ 1∼230 / 3∼400
Reference no. 3465.1-10
Control system for submersible borehole pumps
Design: Pump control system in control cabinet for cascade starting and stopping of up to 6 pumps on the mains.
Applications: Water supply systems.
hyatronic N
No. of pumps _____ max. 6 [kW] ________________ 22Voltage [V] _______ 3∼400
Reference no. 0543.5026-10
Pump control system for cascade starting and stopping
52
Design: Pump control system in control cabinet for asynchronous motors of all types and makes for controlling and monitoring hydraulic systems.
Applications: Heating, ventilation and air-conditioning systems, water supply and drainage systems.
hyatronic mb
No. of pumps _____ max. 8 FI _______________ max. 2[kW] _______________ 200Voltage [V] _______ 3∼400
Reference no. 0974.5-10
Pump control system for continuously variable speed adjustment
Design: Control system for pumps with three-phase motors of all types and makes, consisting of a KSB controller with display and control panel and all required power components.
Applications: Industrial and process engineering circuits, service water supply, cooling and lubrication, energy supply in cogeneration plants, heat transfer and district heating stations, water extraction and treatment, water supply and waste water disposal.
Hyamaster ISB
No. of pumps _____ max. 8 FI _______________ max. 2[kW] _______________ 200Voltage [V] _______ 3∼400
Reference no. 1961.5-10
Pump control system for continuously variable speed adjustment
S p e e d c o n t r o l
Design: Self-cooling frequency inverter which allows the motor speed to be varied continuously by means of standard signals and a field bus. Because PumpDrive is self-cooling, it can be mounted on the motor, on the wall or in a cabinet. Control of up to 6 pumps without an additional controller (with PumpDrive Advanced).
Applications: Cooling circuits, filters, water supply systems, heating, ventilation and air-conditioning systems, spray irrigation systems, boiler feed systems, steam generation plants, process engineering circuits, cooling lubricant supply systems, service water supply systems and other process engineering applications.
PumpDrive
No. of pumps _____ max. 6 FI _____ 1 per pump/motor[kW] ________________ 45Voltage [V] __ 3∼380 to 480
Reference no. 4070.5-10
Self-cooling, motor-independent variable-speed system
Design: Single-pump control system for continuously variable speed adjustment with integrated frequency inverter.
Applications: Heating, ventilation, air-conditioning, water supply and drainage systems.
hyatronic spc
No. of pumps _____ max. 1FI _______________ max. 1[kW] _______________ 7.5Voltage [V] _______ 3∼400
Reference no. 0973.5-10
Pump control system for continuously variable speed adjustment
Design: Control system for pumps with three-phase motors of all types and makes, consisting of a programmable logic controller (PLC) with display and control panel and all required power components housed in a control cabinet.
Applications: Process engineering circuits, service water supply, cooling and lubrication systems, cogeneration plants, heat transfer and district heating stations, water extraction and treatment, water supply and waste water disposal.
Hyamaster SPS
No. of pumps _____ max. 4 FI ___________ 1 per pump[kW] _______________ 650Voltage [V] _______ 3∼400
Reference no. 1964.5-10
Pump control system for continuously variable speed adjustment
53
M o n i t o r i n g a n d d i a g n o s t i c s y s t e m s
Design: Monitoring system for submersible waste water pumps with shutdown.
Amacontrol
No. of pumps _____ max. 1 Type ___________ AmacanInstallation _____ mounting ____________ plate IP20Voltage ________ 230 V AC
Reference no. 2316.178-10
Monitoring system for submersible waste water pumps
Design: The PumpMeter device is an intelligent pressure transmitter for pumps, with on-site display of measured values and operating data. The device consists of two pressure sensors and a display unit. It records the load profile of the pump in order to indicate any potential for optimising energy efficiency and availability.
Applications: For monitoring the operation of a centrifugal pump.
PumpMeter
No. of pumps _____ max. 1 Type see pump type seriesInstallation ______ factory- ________ mounted, IP 65 Voltage _________ 24 V DC
Reference no. 4072.5-10
Intelligent pressure transmitter
0506
.02/
17-1
0 /
01
.11
/
© K
SB A
ktie
ng
esel
lsch
aft
2011
Sub
ject
to
tec
hn
ical
mo
dif
icat
ion
wit
ho
ut
pri
or
no
tice
.
KSB AktiengesellschaftJohann-Klein-Straße 967227 Frankenthal (Germany) www.ksb.com
More space for solutions.
Your local KSB representative: