pu.edu.pkpu.edu.pk/images/image/tender-notices/tender_documents-sbs.docx · web viewpu.edu.pk

37
SCHOOL OF BIOLOGICAL SCIENCES UNIVERSITY OF THE PUNJAB Tel: 35953150 Fax: 99230980 TENDER DOCUMENTS Sealed Tenders are invited from the GST & Income Tax registered Firms/ Distributors/ Dealers/supplier for the supply of following mentioned items (C&F and FOR basis Lahore) shall be received up to 02-04-2019 (01:00 pm) and shall be opened by the Institutional Purchase Committee on same day at 02:30pm in the presence of the bidders or their authorized representatives who may wish to attend. 01. PLANT GROWTH CHAMBER: 01No. Climatic chamber with steam humidifier, forced air convection, chamber capacity: 740 liter or more, stainless steel interior & exterior, double door: internal glass and external solid, temperature range from -10°C to +100°C, humidity range: 10-90%, temperature resolution every: 0,1°C, humidity resolution every: 1%, , test results memory, USB port, Ethernet interface, multi- segment temperature-time-humidity profile, 5 stainless steel shelves, accessa port, open door alarm, door lock, open door counter, equipped with a container for waste water, compressor based technology, three light cassettes directly above sample should be standard. 02. REFRIGERATED CENTRIFUGE MACHINE: 01No. Imbalance switch off, Automatic rotor recognition, Centrifuging chamber of stainless steel, Lid locking and holding during rotor run, Lid dropping protection, Motor overheating protection, Chamber overheating protection, Max Speed: 15000rpm or more, Max RCF: 24000xg or more, Max capacity: 4 x 290ml or better, Temperature range: -20 to +40C, Timer: 1-99min or continuous. Short acceleration and braking with different rates. Adapters for 15 ml ,50 ml falcon tubes and 1.5 ml tubes have to be used with purchased rotors aerosol tight lids. i) Swing Out Rotor with bio-containment lid: Capacity: 16 x 50ml falcon tube, Speed: 5000rpm or more, RCF: 4700xg or more. ii) Swing Out Rotor: Capacity: 12 x MTP, Speed: 5000rpm or more, RCF: 3800xg or more.

Upload: ngoxuyen

Post on 16-Jun-2019

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

SCHOOL OF BIOLOGICAL SCIENCESUNIVERSITY OF THE PUNJAB

Tel: 35953150 Fax: 99230980

TENDER DOCUMENTS

Sealed Tenders are invited from the GST & Income Tax registered Firms/ Distributors/ Dealers/supplier for the supply of following mentioned items (C&F and FOR basis Lahore) shall be received up to 02-04-2019 (01:00 pm) and shall be opened by the Institutional Purchase Committee on same day at 02:30pm in the presence of the bidders or their authorized representatives who may wish to attend.01. PLANT GROWTH CHAMBER: 01No.

Climatic chamber with steam humidifier, forced air convection, chamber capacity: 740 liter or more, stainless steel interior & exterior, double door: internal glass and external solid, temperature range from -10°C to +100°C, humidity range: 10-90%, temperature resolution every: 0,1°C, humidity resolution every: 1%, , test results memory, USB port, Ethernet interface, multi-segment temperature-time-humidity profile, 5 stainless steel shelves, accessa port, open door alarm, door lock, open door counter, equipped with a container for waste water, compressor based technology, three light cassettes directly above sample should be standard.

02. REFRIGERATED CENTRIFUGE MACHINE: 01No.Imbalance switch off, Automatic rotor recognition, Centrifuging chamber of stainless steel, Lid locking and holding during rotor run, Lid dropping protection, Motor overheating protection, Chamber overheating protection, Max Speed: 15000rpm or more, Max RCF: 24000xg or more, Max capacity: 4 x 290ml or better, Temperature range: -20 to +40C, Timer: 1-99min or continuous. Short acceleration and braking with different rates. Adapters for 15 ml ,50 ml falcon tubes and 1.5 ml tubes have to be used with purchased rotors aerosol tight lids.i) Swing Out Rotor with bio-containment lid: Capacity: 16 x 50ml falcon tube, Speed:

5000rpm or more, RCF: 4700xg or more.ii) Swing Out Rotor: Capacity: 12 x MTP, Speed: 5000rpm or more, RCF: 3800xg or more.iii) Angle Rotor: 6 x 85ml with adaptor of 15ml & 50ml falcon tube, Speed: 11000rpm or

more, RCF: 16200xg or more.iv) Angle Rotor: 30 x 1.5/2ml tube single row, Speed: 15000rpm or more, RCF: 24200xg or

more.

03. MULTISCAN ELISA READER: 01No.Compact absorbance reader with LED technology. Reader providing fast, accurate and reproducible data supplied with standard 21 CFR part 11 compliant LT-com PC software for Full qualitative and quantitative analysis functionality including all major curve fits. Fully flexible data exporting options including Excel®, ASCII and ASTM. Comprehensive QC features including plate to plate QC. Comprehensive kinetic data reduction capability for easy set-up within minutes. Fast, accurate & reproducible. Proven reliability. Filters: 8 position wheel with 4 filters. Shaking: linear with 4 modes. Light source: LED, self calibrating. Detectors: Silicon photodiodes. Measurement channels: 8 + 1 reference. Wavelength range: 200 – >900 nm with 1 nm steps. Wavelength selection: Filter (8 filter positions). Supplied filters: 405, 450, 492 and 620 nm. Plate formats 96 well, 384 well (including strip micro plates). Fast reading of all types of micro well plates Measurement range: 0 – 4 OD. Resolution: 0.0001 OD. Accuracy at 450 / 492 nm 0.000 – 2.000 OD ≤ (0.5% + 0.010 OD) typical, 2.000 – 3.000 OD: ≤ (1.0% + 0.010 OD) typical. Precision / Reproducibility at 450 / 492 nm: 0.000 – 2.000 OD: ≤ (0.5% + 0.005

Page 2: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

OD) typical, 2.000 – 3.000 OD: ≤ (1.0% + 0.005 OD) typical. Linearity 0.000 – 2.000 OD: ≤ 1.0%, 2.000 – 3.000 OD: ≤ 1.5%. Computer Interface: USB 1.1/2.0. Power Supply: 240 V AC, 50 / 60 Hz (autosensing)

04. MULTISCAN SPECTROPHOTOMETER: 01No.Double beam, mirrors coated for long life, Modified Czerny-Turner design using holographic diffraction grating, Two silicon diode detectors, Self Test and Calibration, Wavelength Range and Wavelength accuracy 190-1100nm; ±0.3nm for entire range ± 0.1 nm (656.1nm D2), Wavelength Reproducibility 0.1nm, Digital display of Wavelength Readout, Optical Bandwidth < 1nm, Stray Light Less than 0.02% at 220nm, NaI; and 0.02% at 340nm, NaNO2, Large backlit LCD displays spectra, menus, data, prompts and instrument status, Spectra 1st to 4th derivatives, Automatic zero option, Photometric Accuracy ±.004A at 1A, Photometric Noise Less than ±0.0001A at 550nm, 2nm b/width, Baseline Stored in non-volatile memory, Baseline Flatness ±0.001A (300nm/min, 200-1100nm) 2nm bandwidth, Baseline Stability Better than ±0.0001A/hour, RS 232 c, Scan Speeds 1-4000nm/min, Wavelength Scale Expansions 1-100nm/cm, Reaction Kinetics With plots, reprocessing of data as required, for single cell or up to 6 cells, Up to 8 scans may be overlaid, Cell Programming Up to 4, 6 or 8 cells, Program Cycles From 1 to 9999, Power Requirements: 250V, 50/60Hz.

05. EGG INCUBATOR: 01No.Double-walled doors. Protection of the electrical system with fire retardant treatment. Interior completely made of stainless steel with electro polished treatment. 4 individual positioning trays. LED interior light with timed auto-off. Height adjustable legs.  Electronic PID control with programmable digital temperature and humidity DISPLAY-LED. LCD display with LED illumination and language selection. Decimal humidity programming range from 10% RH to 70% RH Programming range of decimal temperature scale from 20.0ºC to 45.0ºC (68ºF to 113ºF). Automatic humidity system type HS-SINF with external tank. Variable speed electronic ventilation system.  Natural Cool Down Programmable NCDP with programmable functions: Cooling intervals (1h to 24h). Cooling temperature with respect to SET (-0.2°C to -20°C). Cooling period duration (1 to 59 minutes).  Automatic turning system NATAP with servo motor with 45 ° with programmable functions: Fixed / Random programming Selector. Programmable start and stop tumbling intervals. Turn of turns interval (5 minutes - 24 hours).  Over voltage/transitory protection circuit. Double safety thermostat with adjustable.

06. SPRAY DRYER: 01 No.Adjustable particle size (2 to 25 microns), highly reproducible powder production at lab scale, drying rate: upto 1L/hr, Intuitive handling, scale upto pilot or industrial scale possible, Fast setup and cleaning time, Visible process due to glass assembly, Evaporation capacity: 1.0L/hr H2O, higher for Organic solvents, Temperature range: Max. temperature input 220C, Drying time: 1.0 to 1.5S

07. PRECISION INCUBATOR: 01 No.Capacity: 256L or more, Natural convection, Continuous adjustment of pre- heated fresh air admixture, Vent connection with restrictor flap, Electronic microprocessor PID- controller with continuous power adaption, Solid state switching unit, Auto Diagnostic System with fault indication, Integrated digital timer, preset time from 1min to 999 hours, Digital display (LED) of set and actual temperature and or (remaining) Program time, LEDs for indication of program status, Display of set function (e.g. loop), Serial interface RS 232 including Memmert software: Celsius 2000”, Incl. works calibration certificate for +37 °C .

Page 3: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

08. REAL TIME PCR SYSTEM: 01 No.The real-time PCR detection system should have precise quantification and target discrimination for up to 5 targets in large-volume reactions having following specifications, The heating and cooling block must be Solid state Peltier based. For fast ramping the honey comb Block architecture is required. The system should be compatible with 96 well and 384 well microplates. The sample volume capacity must be upto 1-50uL. Operating thermal range must be 0-100 °C. Thermal accuracy: ±0.2 of programmed target at 90°C. Thermal Uniformity: ±0.4 well-to-well within 10 sec of arrival at 90°C. Optical Excitation Filters: 6 Filtered LEDs. Optical Detection Filters: 6 filtered photodiodes. Wavelength Range required from 450-730 nm. It should be able to operate without computer support. It should have Thermal gradient capable. Programmable thermal gradient Span: 1-24°C. Multiplex Analysis: Up to 5 Targets per well. Chemistries: Dye based, Probe based and FRET. Maximum ramp rate, °C/sec: 5. Average ramp rate, °C/sec: 3.3. The Software must be able to be installed on multiple computer systems. Software must not need to be connected to instrument for its functioning, viewing and analysis of date. Post run data files must be transferable to other computers for analysis. Software must have capability of modification while running. Software must have capability of modification upon completion. Software must be capable of calculating Ta of the specific primers. Software must have capability of automatically writing protocols. The software must have capability to show various chart types including: Graphing (Bar, Box and whisker chart, Cluster gram, Scatter Plot, Heat Map, Statistical tools: One-way or two-way ANOVA. All necessary software’s and accessories should be inclusive, nothing optional.

09. CRYOPRESERVATIVE SYSTEM: 01No.Cryopreservative system should be capable for cryopreservation of mammalian cell with boxes holding capacity ultrasonic level monitor should be standard. LN2 capacity of 71 liters with per pack unit 4 and box capacity per rack of 5. 2 ml Vials capacity should be hundred with full unit of 2000. Static holding time should be more than 80 days.

10. WESTERN BLOTTING SYSTEM WITH ACCESSORIERS: 03Nos.The system should run mini-gels quickly, Should be ideal for wet electroblotting of proteins. Should have Platinum Plate electrodes for increased speed of Transfer. Hinged cassettes should be added for convenience. System should Accommodate gel thicknesses from 0.25 up to 3mm. Unit Dimension: 19 x 13 x 15, Capacity: 2 Gels, Typical Running Conditions: 100-200V, 1-2h, Gel Dimension: 8 x 8.5, Maximum Buffer Volume: 1300, Blotter Type: Wet Blot. Universal power cord compatible with most power supplies.

11 ELECTROPORATOR WITH ACCESSORIES: 02Nos.The electroporator system should be flexible with Cuvette method. System should be Open system for use of Cuvettes 1mm, 2mm or 4mm. Must be supplied Cuvettes 1mm, 2mm and 4mm with system (Pkt of 50 each). Capacitor: 10 Microfarad, Pulse voltage: 200-2500v, Resistance: 600 Ohm, Instrument should have fast, freely programmable soft keys for saving and accessing the 2 most frequently used parameters. Electronic preventive circuit to prevent. Integrated cuvette system with notable “click” sound to ensure proper attachment of insert, Should be single button operation. Documentation storage should be via USB.

12- BLUE LIGHT LED TRANSILLUMINATOR: 01NoThe system should have a large surface area, and serve as the perfect workstation for viewing and working with fluorescently-stained protein and nucleic acid gels. No DNA damage to

Page 4: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

samples. Should be safer for user. No UV light. High Purity LED Light. Strong Metal Enclosure with Stainless steel filter frame. Fast start up. Filter Size should be more than 150 x 100 mm. Light Source: 470nm Blue LED’s. Voltage: 240V. Should have compatibility and adaptor for connecting inside most gel documentation systems. Should provide optimal excitation for SYBR® Safe DNA gel stain and compatible for use with other nucleic acid and protein stains such SYBR® Gold, SYBR® Green I & II, SYPRO® Ruby, SYPRO® Orange, and Coomassie Fluor™ Orange stains, Should comply with international Safety requirements, Light source: Class 1 light emitting diodes (LED) producing a narrow emission peak centered at ~470 nm, LED life should be at least 50,000 hours, LED safe to skin and damage to DNA. Should be included with all accessories like amber filter unit, viewing glasses, and international power cord

13. GENERAL AND EQUIPMENT’S ACCESSORIES:(A) GENERAL ACCESSORIES:Sr # Description Qty01. MALDI-MS Starter kit for calibration Bruker Part No. 8208241 01No.02. Resistive steel capillary Agilent Cat # G1960-80060 02Nos.03. Standard nebulizer tested Agilent Cat # G1958-67098 02Nos.

04.

O-Rings of Skimmer and vacuum manifoldAgilent Cat # 0905-1466Agilent Cat # 0905-1467Agilent Cat # 0905-1468Agilent Cat # 0905-1469Agilent Cat # 0905-1470Agilent Cat # 0905-1471Agilent Cat # 0905-1698Agilent Cat # 0905-1703

02each

05. Poroshell 300SB-C18 analytical 2.1x75mm-5 micron (LC MS column)Agilent Cat # 6607580-902 02pcs

06. ESI- tuning mix Agilent Cat # G 1969-85000 02bottles07. ESI- reference ion solution kit Agilent Cat # G1969-85001 01bottle08. Glass filters Agilent Cat # 5041-2168 04Nos.09. CDS bottle Agilent Cat # 9300-2576 02bottles10. Flushing solvent Agilent Agilent Cat # G1969-85026 02bottles11. Female union luer adaptor Agilent Cat # 0100-2304 01pkt12. Quick Connect Assay ST 0.17x150mm Agilent part number -5067-6167 02Nos.13. Quick Connect Assay ST 0.17x220mm Agilent part number 5067-6168 02Nos.

14.

Service kit for Noblegen nitrogen generator NG6-1; 12000 operations hours ServiceSilencer ANA1-04, SMCControl relays, FinderFilter spare kit,SMC-1Relay Omron1/2 Sol service kit, EmersonCompressors service kit,GAST

04Nos.06Nos.01Nos.02Nos.06Nos.02Nos.

15. Edwards Vacuum pump oil (Edwards) compatible with LC MS 6224 01x4Ltr

16. microbore column BDS Hypersil C18 (50 x 2.1)Thermo Scientific Part # 28102-052130 03Nos.

17. Analytical column C4 (250 x 4.6) Thermo Scientific Part # 72305-254630 03Nos.

18. Analytical column C8 BDS Hypersil (250 x 4.6),Thermo Scientific Part # 28205-254630 03Nos.

19. Analytical column C18 BDS Hypersil (250 x 4.6)Thermo Scientific Part # 28105-254630 03Nos.

Page 5: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

Sr # Description Qty

20. Semi-preparative column C4 (250 x 10)Thermo Scientific Part # 72305-259070 03Nos.

21. Semi-preparative column C8 (250 x 10),Thermo Scientific Part # 72205-259070 03Nos.

22. Semi-preparative column C18 (250 x 10),Thermo Scientific Part # 72110-259070 03Nos.

23. Gel Filtration column SuperdexTM 200 Increase 10/300 GL (10x300mm Bed dimension) Product No. 2899044 01No.

24.Hamilton® syringe, 700 series, special needleVolume: 0.5 mL  Size: 22 ga (blunt tip)Needle L: 51 mm (2 in.)  Part # 26222-U,

02Nos.

25. Nitrocellulose membrane (Hybond N+)Amersham Biosciences Cat # RPN203B 05rolls

26.Hamilton® syringe, 700 series, special needleVolum: 100 μL  Size: 22s ga (blunt tip)Needle L: 51 mm (2 in.)  Part # 58383

2Nos.

27.Hamilton® syringe, 700 series, special needleVolum: 25 μL  Size: 22s ga (blunt tip)Needle L: 51 mm (2 in.) Part # 58381

3Nos.

28.Hamilton® syringe, 700 series, special needleVolum: 250 μL  Size: 22 ga (blunt tip)Needle L: 51 mm (2 in.)  Part # 58384

2Nos.

29. Rheodyne™ Sample Loops for 20µL Part # 7755-022 01No.30. Rheodyne™ Sample Loops for 200µL Part # 7755-025 01No.31. Rheodyne™ Sample Loops for 500µL Part # 7755-026 01No.32. Rheodyne™ Sample Loops for 1mL Part # 7755-027 01No.33. Rheodyne™ Sample Loops for 2mL Part # 7755-028 01No.34. Rheodyne™ Sample Loops for 5mL Part # 7755-029 02Nos.35. Rheodyne™ Sample Loops for 10mL Part # 9055-033 02Nos.36. Fast acid analysis HPLC Column Bio- Rad Cat # 1250100 01No.37. Micro-Guard De- Ashing Refill Cartridges Bio Rad Cat # 1250118 04Nos.

38. Standard Cartridge Holder for HPLC systemsBio Rad Cat # 1250139 01No.

39. Deashing Cartridge Holder Bio-Rad Cat # 1250139 01No.40. Aminex HPX-87H Column BioRad Cat # 1250140 01No.41. Aminex HPX-42A Column BioRad Cat # 1250097 01No.42. Micro-Guard Cation H Refill Cartridges BioRad Cat # 1250129 03Nos.43. Standard Cartridge Holder for HPLC Systems BioRad Cat # 1250131 01No.44. Micro-Guard Anion CO3- Cartridges BioRad Cat # 1250506 02Nos.45. Cartridge Holder Seals BioRad Cat # 1250148 01No.46. Fast Acid Analysis Column BioRad Cat # 1250100 01No.47. Fermentation Monitoring Column BioRad Cat # 1250115 01No.48. Bio-Gel P-2-gel Biorad cat#1504114 01x100gm49. Bio-Gel P-4-gel Biorad cat#1504128 01x100gm

50. CarboPac PA-100 Analytical Column (4 x 250 mm)ThermoFisher Scientific Dionex Cat # 043055 01No.

51. CarboPac PA-100 Guard Column (4 x 50 mm)ThermoFisher Scientific Dionex Cat # 043054 01No.

52. CarboPac PA-100 Preparative Column (22 x 250 mm)ThermoFisher Scientific Dionex Cat # SP2667 01No.

Page 6: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

Sr # Description Qty53. Resource Q GE Healthcare Cat # GE17-1179-01 02Nos.

54. HiTrap® Heparin High Performance (5/pkt)GE Healthcare Cat # GE 17-0407-03 01pkt

55. HiTrap® Phenyl Fast Flow (HS) (5/pkt)GE Healthcare Cat # GE 17-5193-01 01pkt

56. Gel filtration column SuperdexTM 200 10/300 GLGE Healthcare Part # 17-5175-01 03Nos.

57. Gel filtration column SuperdexTM 75 10/300 GLGE Healthcare Part # 17-5174-01 02Nos.

58. PD-10 Desalting column GE Healthcare Codes Cat # GE17-0851-01 40-purifications59. MicroSpinTM G-25 columns Cat # GE Healthcare 27-5325-01 01pkt

60. Centrifuge tubes with screw capped lids (Beckman coulter) 50 mL (Autoclaveable), 100mL, 200 mL, 1000 mL Polycarbonate, 12 tubes.

61. Centrifuge tubes screw capped lids (Beckman coulter) 50 mL (Autoclaveable), 100mL, 200 mL, 1000 mL Polypropylene, 12 tubes.

62. Centrifuge tubes screw capped lids (Beckman coulter) 50 mL (Autoclaveable), 100mL, 200 mL, 1000 mL Teflon, 12 tubes.

63. Oil for vacuum pumps (freeze driers) Pfeiffer P3 Oil 10Ltr64. Thin Layer Chromatography Chambers 02Nos.

65. Slide-a-Lyzer Dialysis cassette 3500 MWCO, 0.5 – 3 ml capacity,Thermo scientific Cat # 66330-, 01pack

66. Sep-Pak Cartridges Classic C18 – Waters part no: WAT051910 01pack67. Oasis PLUS HLB – cartridges – Waters part no: 186000132 01pack

68. Dowex resin (50Wx8 (Hydrogen form, 50–100 mesh)Sigma Aldrich-Merck Cat # 217492- 01x100gm

69. Poly (acrylic acid sodium salt) Sigma Aldrich-Merck Cat # 447013-100G 01x100gm70. Glucopon 600 (G600) Sigma Aldrich-Merck Cat # 49122 01 pack

71. Pierce™ Protein Concentrator, Cat # 88527, PES, 10K MWCO, 5-20 mL, 10 reactions 01pkt

72. Pierce™ Protein Concentrator, Cat # 88529, PES, 30K MWCO, 5-20 mL, 10 reactions 01pkt

73. Vivaspin 2 centrifugal concentratorsCut off size 3 and 10 kDa (100/pkt) 01pkt each

74. Thin layer chromatography Silica gel plates 05pkts75. Hi prep 16/60 Sephacrly. S-200 HR Column Cat # 17-1166-01 01x120ml

(B) Accessories/Spare parts for HPLC, SYKAM-Germany01. Pressure Sensor required for Pump Model: S1121 02Nos.02. Relief Valve required for Pump Model: S1121 02Nos.03. D2 Lamp required for UV-VIS Detector: Model S3210 03Nos.04. Stainless Steel tubing 02Meter05. Stainless Steel Fittings and Ferrules 10each06. Check Valve cartridges for Pump 05Nos.07. Piston for pump (analytical) 04Nos.08. Primary and Secondary seals for Pump 08Nos.09. PTFE sealing and quartz lens for flow cell of UV-Vis Detector 04sets10. Peek Fittings 10Nos.

Page 7: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

Sr # Description Qty(C) Accessories for FPLC AKTA system GE/Amersham Biosciences

01. D2 UV lamp for UV-900 03Nos.02. Pump required for model P-900, flow rate 100 ml/min for AKTA purifier 02Nos.03. Pump required for model P-900, flow rate 10 ml/min for AKTA Explorer 02Nos.

04. Pistons required for Pump Model: P-900 Flow rate 100ml/min for AKTA purified 02Nos.

05. Pistons required for pump Model P-900 02Nos.06. Reference Fiber OPTIC 02Nos.07. Sample Fiber OPTIC 02Nos.08. V Injection Value for INV 907 01No.09. Cog belt for Pump P 900 flow 100ml/min 02Nos.10. Resistant starch assay kit Megazayme cat # K-RSTAR 01kit11. Total Starch Assay kit Megazayme cat # K-TSTA-100 A 01kit

TERMS AND CONDITIONS:-1. General:1.1 Any offer not received as per terms & conditions of the tender enquiry is liable to be ignored and also no

offer shall be considered if:a. Received without earnest money.b. It is received after the time and date fixed for its receipt.c. Not signed & stamped by authorized person on tender documents.d. The offer is ambiguous.e. The offer is received by fax or e-mail.f. The offer is from a black listed firm.g. Offer received with shorter validity than required.h. The offer is for store not conforming to specifications indicated in the tender enquiry.i Any conditional offer.

1.2 Offered rates will remain valid for a period of 90 days after bid opening. No change in price will be made in case of Pak rupees depreciation against foreign currency.

1.3 The cover envelop should indicate particulars of tender, date of opening and the envelope must be properly sealed.

1.4 In case the tenderer fails to execute the order strictly in accordance with the terms and conditions mentioned in the tender, security deposited by the bidder shall be forfeited.

1.5 The bidder should indicate their National Income Tax No. / Sales Tax No. and circle of Income Tax Department.

1.6 The contractor will be responsible for the free replacement of supplied item if the same is found to be substandard and or at variance with the specifications given in the supply order. Items offered of specifications superior to the one specified in the tender enquiry may be accepted subject to the approval of competent authority.

1.7 Items should be brand new and by original manufacturers.1.8 Offered rates will be on basis of free replacement (installation/commissioning).1.9 All Tenders can be cancelled by the Competent Authority before acceptance of the bid (s) as per PPRA

Rules 2014, Clause 35.1.10 Offer must be supported with comprehensive technical literature and specifications in original (English) for

the materials/goods offered. Bid is liable to be disqualified if relevant literature/specifications are not attached with the offer.

1.11 Bids will be evaluated by the departmental Technical Committee on cost and quality basis.

Page 8: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

1.12 In case of local supply, prices should be excluding GST and it will be added at the time of comparison.1.13 The specifications/details can be obtained from the office of the School of Biological Sciences, University of

the Punjab, Lahore during the official hours at a cost of Rs.2,000/= non refundable.1.14 Bids should be on C&F and FOR basis Lahore as mentioned above.1.15 Please avoid quoting alternative offers. Alternative offers will not be considered.2. Delivery Period:2.1 Delivery period is 90 days after issuance of Purchase Order for the procurement required for local purchase.

The equipments to be provided should be of original make/genuine quality. The contractor shall stand guarantee for the equipments for a minimum period of one year.

2.2 The contractor will be responsible for the free replacement of supplied item if the same is found to be substandard and or at variance with the specifications given in the supply order within 30 days. Items offered of specifications superior to the one specified in the tender enquiry may be accepted subject to the approval of Competent Authority.

3. Extension of Delivery Period:In special circumstances, request for extension of delivery period may be considered by the approving authority on the written request of the firm before the target date of supply.

4. Cancellation & Penalty of Delay:4.1 In case of delayed supply, the purchaser may cancel the supply order or impose appropriate penalty. The

penalty will be as per University laid down rule.4.2 In case, the bidder fails to execute the contract in accordance with the terms and conditions laid down in the

contract, bid money will be forfeited.5. Payment to the Contractor:5.1 Payment will be made through crossed cheque to the supplier against invoice after 100% completion of

delivery and commissioning after satisfactory performance against the purchase order.5.2 Payment against partial supply will not be made.6. Bid Money:6.1 Fix bid money of 02% for the estimated price of the tender will have to be deposited along with the tender.

It should be in the form of Pay Order/Demand Draft in favour of Director General, School of Biological Sciences, University of the Punjab, Lahore.

6.2 Bid money of successful bidder shall be refunded on successful completion of the warranty period. Whereas bid money of unsuccessful bidders will be refunded on the approval of the tender by the Competent Authority.

7. Inspection:The equipments will be inspected by Technical personals of School of Biological Sciences, University of the Punjab, Lahore who will coordinate with the contractor in lieu of required job as per tender requirements, specifications quality and terms of the contract.

8. Deduction of Taxes:Any taxes (if applicable) will be deducted while making payment as per Government instructions/notifications.

9. Payment of Sales & Other Taxes, Duties, Levies:All taxes and any other duties if applicable will be liability of the firm. Purchase & Services shall be made from the firm registered with income tax and sales tax under Punjab Revenue Authority if applicable.

10. Dispute Resolution:In case of any disputer before or after the execution of contract, matter will be resolved as per PPRA Rules 2014’ Clause 67 & 68.

11. Eligibility Criteria:a.Manufacturers, Authorized Dealers, Suppliers (Firms).

Page 9: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

b.Copies of Sale Tax/Income Tax registration certificates.c. Only exclusive/authorized distributors should quote the tender.d.For quoted items, distributor must submit the sole distribution certificate with bid that will be checked later

on and verified from company. e. At the time of delivery, import documents will be checked.f. Chinese/Taiwan and Korean companies are not acceptable.g. All softwares, accessories, consumables etc. required for complete functioning of an equipment/scientific

instrument should be included in the quoted price. No quote for any optional item will be entertained.h. For scientific instruments required warranty will be at least for one year preferably for longer period.

Warranty period will start from the date of installation.i. The bidders also have to provide documents proving the availability of trained certified engineer (s) for

installation and services of their quoted scientific instruments.12. Estimated value of tender is 25 million.

NOTE (i) Above mentioned Technical Criteria documents must be attached, failing which will leads towards disqualification of the bid.

(ii) Bidders are requested to send soft copies of the tenders in Microsoft word format at below mentioned E-mail address after opening the tender on immediate basis. [email protected]

TENDER QUOTATIONSSr# Name of Items Specifications Qty U Price Total Price

01.

PLANT GROWTH CHAMBER:

Climatic chamber with steam humidifier, forced air convection, chamber capacity: 740 liter or more, stainless steel interior & exterior, double door: internal glass and external solid, temperature range from -10°C to +100°C, humidity range: 10-90%, temperature resolution every: 0,1°C, humidity resolution every: 1%, , test results memory, USB port, Ethernet interface, multi-segment temperature-time-humidity profile, 5 stainless steel shelves, access port, open door alarm, door lock, open door counter, equipped with a container for waste water, compressor based technology, three light cassettes directly above sample should be standard.

01No.

02.REFRIGERATED CENTRIFUGE MACHINE:

Imbalance switch off, Automatic rotor recognition, Centrifuging chamber of stainless steel, Lid locking and holding during rotor run, Lid dropping protection, Motor overheating protection, Chamber overheating protection, Max Speed: 15000rpm or more, Max RCF: 24000xg or more,

01No.

Sr# Name of Items Specifications Qty U Price Total Price

Page 10: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

Max capacity: 4 x 290ml or better, Temperature range: -20 to +40C, Timer: 1-99min or continuous. Short acceleration and braking with different rates. Adapters for 15 ml ,50 ml falcon tubes and 1.5 ml tubes have to be used with purchased rotors aerosol tight lids.i) Swing Out Rotor with bio-containment lid: Capacity: 16 x 50ml falcon tube, Speed: 5000rpm or more, RCF: 4700xg or more.ii) Swing Out Rotor: Capacity: 12 x MTP, Speed: 5000rpm or more, RCF: 3800xg or more.iii) Angle Rotor: 6 x 85ml with adaptor of 15ml & 50ml falcon tube, Speed: 11000rpm or more, RCF: 16200xg or more.iv) Angle Rotor: 30 x 1.5/2ml tube single row, Speed: 15000rpm or more, RCF: 24200xg or more.

03.MULTISCAN

ELISA READER:

Compact absorbance reader with LED technology. Reader providing fast, accurate and reproducible data supplied with standard 21 CFR part 11 compliant LT-com PC software for Full qualitative and quantitative analysis functionality including all major curve fits. Fully flexible data exporting options including Excel®, ASCII and ASTM. Comprehensive QC features including plate to plate QC. Comprehensive kinetic data reduction capability for easy set-up within minutes. Fast, accurate & reproducible. Proven reliability. Filters: 8 position

01No.

Page 11: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

Sr# Name of Items Specifications Qty U Price Total Pricewheel with 4 filters. Shaking: linear with 4 modes. Light source: LED, self calibrating. Detectors: Silicon photodiodes. Measurement channels: 8 + 1 reference. Wavelength range: 200 – >900 nm with 1 nm steps. Wavelength selection: Filter (8 filter positions). Supplied filters: 405, 450, 492 and 620 nm. Plate formats 96 well, 384 well (including strip micro plates). Fast reading of all types of micro well plates Measurement range: 0 – 4 OD. Resolution: 0.0001 OD. Accuracy at 450 / 492 nm 0.000 – 2.000 OD ≤ (0.5% + 0.010 OD) typical, 2.000 – 3.000 OD: ≤ (1.0% + 0.010 OD) typical. Precision / Reproducibility at 450 / 492 nm: 0.000 – 2.000 OD: ≤ (0.5% + 0.005 OD) typical, 2.000 – 3.000 OD: ≤ (1.0% + 0.005 OD) typical. Linearity 0.000 – 2.000 OD: ≤ 1.0%, 2.000 – 3.000 OD: ≤ 1.5%. Computer Interface: USB 1.1/2.0. Power Supply: 240 V AC, 50 / 60 Hz (autosensing)

04.MULTISCAN

SPECTROPHOTOMETER:

Double beam, mirrors coated for long life, Modified Czerny-Turner design using holographic diffraction grating, Two silicon diode detectors, Self Test and Calibration, Wavelength Range and Wavelength accuracy 190-1100nm; ±0.3nm for entire range ± 0.1 nm (656.1nm D2), Wavelength Reproducibility 0.1nm, Digital display of Wavelength Readout, Optical Bandwidth < 1nm, Stray Light Less than 0.02% at 220nm, NaI; and 0.02% at 340nm, NaNO2, Large backlit LCD displays spectra, menus, data, prompts and instrument status, Spectra 1st to 4th derivatives, Automatic

01No.

Page 12: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

Sr# Name of Items Specifications Qty U Price Total Pricezero option, Photometric Accuracy ±.004A at 1A, Photometric Noise Less than ±0.0001A at 550nm, 2nm b/width, Baseline Stored in non-volatile memory, Baseline Flatness ±0.001A (300nm/min, 200-1100nm) 2nm bandwidth, Baseline Stability Better than ±0.0001A/hour, RS 232 c, Scan Speeds 1-4000nm/min, Wavelength Scale Expansions 1-100nm/cm, Reaction Kinetics With plots, reprocessing of data as required, for single cell or up to 6 cells, Up to 8 scans may be overlaid, Cell Programming Up to 4, 6 or 8 cells, Program Cycles From 1 to 9999, Power Requirements: 250V, 50/60Hz.

05.EGG

INCUBATOR:

Double-walled doors. Protection of the electrical system with fire retardant treatment. Interior completely made of stainless steel with electro polished treatment. 4 individual positioning trays. LED interior light with timed auto-off. Height adjustable legs.  Electronic PID control with programmable digital temperature and humidity DISPLAY-LED. LCD display with LED illumination and language selection. Decimal humidity programming range from 10% RH to 70% RH Programming range of decimal temperature scale from 20.0ºC to 45.0ºC (68ºF to 113ºF). Automatic humidity system type HS-SINF with external tank. Variable speed electronic ventilation system.  Natural Cool Down Programmable NCDP with programmable functions: Cooling intervals (1h to 24h). Cooling temperature with respect to SET (-0.2°C to -20°C). Cooling period duration (1 to 59 minutes). Automatic turning system NATAP with servo motor with 45 ° with programmable

01No.

Page 13: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

Sr# Name of Items Specifications Qty U Price Total Pricefunctions: Fixed / Random programming Selector. Programmable start and stop tumbling intervals. Turn of turns interval (5 minutes - 24 hours). Over voltage/transitory protection circuit. Double safety thermostat with adjustable.

06. SPRAY DRYER:

Adjustable particle size (2 to 25 microns), highly reproducible powder production at lab scale, drying rate: upto 1L/hr, Intuitive handling, scale upto pilot or industrial scale possible, Fast setup and cleaning time, Visible process due to glass assembly, Evaporation capacity: 1.0L/hr H2O, higher for Organic solvents, Temperature range: Max. temperature input 220C, Drying time: 1.0 to 1.5S

01No.

07.PRECISION INCUBATOR:

Capacity: 256L or more, Natural convection, Continuous adjustment of pre- heated fresh air admixture, Vent connection with restrictor flap, Electronic microprocessor PID- controller with continuous power adaption, Solid state switching unit, Auto Diagnostic System with fault indication, Integrated digital timer, preset time from 1min to 999 hours, Digital display (LED) of set and actual temperature and or (remaining) Program time, LEDs for indication of program status, Display of set function (e.g. loop), Serial interface RS 232 including Memmert software: Celsius 2000”, Incl. works calibration certificate for +37 °C .

01No.

08.REAL TIME PCR SYSTEM:

The real-time PCR detection system should have precise quantification and target discrimination for up to 5 targets in large-volume reactions having following specifications, The

01No.

Page 14: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

Sr# Name of Items Specifications Qty U Price Total Priceheating and cooling block must be Solid state Peltier based. For fast ramping the honey comb Block architecture is required. The system should be compatible with 96 well and 384 well microplates. The sample volume capacity must be upto 1-50uL. Operating thermal range must be 0-100 °C. Thermal accuracy: ±0.2 of programmed target at 90°C. Thermal Uniformity: ±0.4 well-to-well within 10 sec of arrival at 90°C. Optical Excitation Filters: 6 Filtered LEDs. Optical Detection Filters: 6 filtered photodiodes. Wavelength Range required from 450-730 nm. It should be able to operate without computer support. It should have Thermal gradient capable. Programmable thermal gradient Span: 1-24°C. Multiplex Analysis: Up to 5 Targets per well. Chemistries: Dye based, Probe based and FRET. Maximum ramp rate, °C/sec: 5. Average ramp rate, °C/sec: 3.3. The Software must be able to be installed on multiple computer systems. Software must not need to be connected to instrument for its functioning, viewing and analysis of date. Post run data files must be transferable to other computers for analysis. Software must have capability of modification while running. Software must have capability of modification upon completion. Software must be capable of calculating Ta of the specific primers. Software must have capability of automatically writing protocols. The software must have capability to show various chart types including:

Page 15: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

Sr# Name of Items Specifications Qty U Price Total PriceGraphing (Bar, Box and whisker chart, Cluster gram, Scatter Plot, Heat Map, Statistical tools: One-way or two-way ANOVA. All necessary software’s and accessories should be inclusive, nothing optional.

09.CRYOPRESERVATIVE SYSTEM:

Cryopreservative system should be capable for cryopreservation of mammalian cell with boxes holding capacity ultrasonic level monitor should be standard. LN2

capacity of 71 liters with per pack unit 4 and box capacity per rack of 5. 2 ml Vials capacity should be hundred with full unit of 2000. Static holding time should be more than 80 days.

01No.

10.

WESTERN BLOTTING SYSTEM WITH ACCESSORIERS:

The system should run mini-gels quickly, Should be ideal for wet electroblotting of proteins. Should have Platinum Plate electrodes for increased speed of Transfer. Hinged cassettes should be added for convenience. System should Accommodate gel thicknesses from 0.25 up to 3mm. Unit Dimension: 19 x 13 x 15, Capacity: 2 Gels, Typical Running Conditions: 100-200V, 1-2h, Gel Dimension: 8 x 8.5, Maximum Buffer Volume: 1300, Blotter Type: Wet Blot. Universal power cord compatible with most power supplies.

03Nos.

11.ELECTROPORATOR WITH ACCESSORIES:

The electroporator system should be flexible with Cuvette method. System should be Open system for use of Cuvettes 1mm, 2mm or 4mm. Must be supplied Cuvettes 1mm, 2mm and 4mm with system (Pkt of 50 each). Capacitor: 10 Microfarad, Pulse voltage: 200-2500v, Resistance:

02Nos.

Page 16: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

Sr# Name of Items Specifications Qty U Price Total Price600 Ohm, Instrument should have fast, freely programmable soft keys for saving and accessing the 2 most frequently used parameters. Electronic preventive circuit to prevent. Integrated cuvette system with notable “click” sound to ensure proper attachment of insert, Should be single button operation. Documentation storage should be via USB.

12.

BLUE LIGHT LED TRANSILLUMINATOR:

The system should have a large surface area, and serve as the perfect workstation for viewing and working with fluorescently-stained protein and nucleic acid gels. No DNA damage to samples. Should be safer for user. No UV light. High Purity LED Light. Strong Metal Enclosure with Stainless steel filter frame. Fast start up. Filter Size should be more than 150 x 100 mm. Light Source: 470nm Blue LED’s. Voltage: 240V. Should have compatibility and adaptor for connecting inside most gel documentation systems. Should provide optimal excitation for SYBR® Safe DNA gel stain and compatible for use with other nucleic acid and protein stains such SYBR® Gold, SYBR® Green I & II, SYPRO® Ruby, SYPRO® Orange, and Coomassie Fluor™ Orange stains, Should comply with international Safety requirements, Light source: Class 1 light emitting diodes (LED) producing a narrow emission peak centered at ~470 nm, LED life should be at least 50,000 hours, LED safe to skin and damage to DNA. Should be included with all accessories like amber filter unit, viewing glasses, and international power cord

01No.

Page 17: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

13. GENERAL AND EQUIPMENT’S ACCESSORIES:(A) GENERAL ACCESSORIES:

Sr# Name of Items Specifications Qty U Price Total Price

01.MALDI-MS Starter kit for calibration Bruker Part No. 8208241

01No.

02. Resistive steel capillary Agilent Cat # G1960-80060 02Nos.

03. Standard nebulizer tested Agilent Cat # G1958-67098 02Nos.

04.

O-Rings of Skimmer and vacuum manifoldAgilent Cat # 0905-1466Agilent Cat # 0905-1467Agilent Cat # 0905-1468Agilent Cat # 0905-1469Agilent Cat # 0905-1470Agilent Cat # 0905-1471Agilent Cat # 0905-1698Agilent Cat # 0905-1703

02each

05.

Poroshell 300SB-C18 analytical 2.1x75mm-5 micron (LC MS column)Agilent Cat # 6607580-902

02pcs

06. ESI- tuning mix Agilent Cat # G 1969-85000 02bottles

07. ESI- reference ion solution kit Agilent Cat # G1969-85001 01bottle

08. Glass filters Agilent Cat # 5041-2168 04Nos.

09. CDS bottle Agilent Cat # 9300-2576 02bottles

10. Flushing solvent Agilent Agilent Cat # G1969-85026 02bottles

11. Female union luer adaptor Agilent Cat # 0100-2304 01pkt

12.Quick Connect Assay ST 0.17x150mm Agilent part number -5067-6167

02Nos.

13.Quick Connect Assay ST 0.17x220mm Agilent part number 5067-6168

02Nos.

Sr# Name of Items Specifications Qty U Price Total Price

Page 18: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

14.

Service kit for Noblegen nitrogen generator NG6-1; 12000 operations hours ServiceSilencer ANA1-04, SMCControl relays, FinderFilter spare kit,SMC-1Relay Omron1/2 Sol service kit, EmersonCompressors service kit,GAST

04Nos.06Nos.01Nos.02Nos.06Nos.02Nos.

15.Edwards Vacuum pump oil (Edwards) compatible with LC MS 6224

01x4Ltr

16.

microbore column BDS Hypersil C18 (50 x 2.1)Thermo Scientific Part # 28102-052130

03Nos.

17.Analytical column C4 (250 x 4.6)Thermo Scientific Part # 72305-254630

03Nos.

18.

Analytical column C8 BDS Hypersil (250 x 4.6),Thermo Scientific Part # 28205-254630

03Nos.

19.

Analytical column C18 BDS Hypersil (250 x 4.6)Thermo Scientific Part # 28105-254630

03Nos.

20.

Semi-preparative column C4 (250 x 10)Thermo Scientific Part # 72305-259070

03Nos.

21.

Semi-preparative column C8 (250 x 10),Thermo Scientific Part # 72205-259070

03Nos.

22.Semi-preparative column C18 (250 x 10), Thermo Scientific Part # 72110-259070

03Nos.

23.

Gel Filtration column SuperdexTM

200 Increase 10/300 GL (10x300mm Bed dimension) Product No. 2899044

01No.

24.

Hamilton® syringe, 700 series, special needleVolume: 0.5 mL  Size: 22 ga (blunt tip)Needle L: 51 mm (2 in.)  Part # 26222-U,

02Nos.

Sr# Name of Items Specifications Qty U Price Total Price

Page 19: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

25.

Nitrocellulose membrane (Hybond N+)Amersham Biosciences Cat # RPN203B

05rolls

26.

Hamilton® syringe, 700 series, special needleVolum: 100 μL  Size: 22s ga (blunt tip), Needle L: 51 mm (2 in.) Part # 58383

2Nos.

27.

Hamilton® syringe, 700 series, special needleVolum: 25 μL Size: 22s ga (blunt tip)Needle L: 51 mm (2 in.) Part # 58381

3Nos.

28.

Hamilton® syringe, 700 series, special needleVolum: 250 μL  Size: 22 ga (blunt tip)Needle L: 51 mm (2 in.)  Part # 58384

2Nos.

29. Rheodyne™ Sample Loops for 20µL Part # 7755-022 01No.

30. Rheodyne™ Sample Loops for 200µL Part # 7755-025 01No.

31. Rheodyne™ Sample Loops for 500µL Part # 7755-026 01No.

32. Rheodyne™ Sample Loops for 1mL Part # 7755-027 01No.

33. Rheodyne™ Sample Loops for 2mL Part # 7755-028 01No.

34. Rheodyne™ Sample Loops for 5mL Part # 7755-029 02Nos.

35. Rheodyne™ Sample Loops for 10mL Part # 9055-033 02Nos.

36. Fast acid analysis HPLC Column Bio- Rad Cat # 1250100 01No.

37.Micro-Guard De- Ashing Refill CartridgesBio Rad Cat # 1250118

04Nos.

38.Standard Cartridge Holder for HPLC systemsBio Rad Cat # 1250139

01No.

39. Deashing Cartridge HolderBio-Rad Cat # 1250139 01No.

Sr# Name of Items Specifications Qty U Price Total Price

Page 20: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

40. Aminex HPX-87H ColumnBioRad Cat # 1250140 01No.

41. Aminex HPX-42A ColumnBioRad Cat # 1250097 01No.

42.Micro-Guard Cation H Refill Cartridges BioRad Cat # 1250129

03Nos.

43.Standard Cartridge Holder for HPLC Systems BioRad Cat # 1250131

01No.

44.Micro-Guard Anion CO3- Cartridges BioRad Cat # 1250506

02Nos.

45.Cartridge Holder Seals

BioRad Cat # 1250148

01No.

46. Fast Acid Analysis Column BioRad Cat # 1250100 01No.

47.Fermentation Monitoring Column

BioRad Cat # 1250115

01No.

48. Bio-Gel P-2-gel Biorad cat#1504114 01x100gm

49. Bio-Gel P-4-gel Biorad cat#1504128 01x100gm

50.

CarboPac PA-100 Analytical Column (4 x 250 mm)ThermoFisher Scientific

Dionex Cat # 043055

01No.

51.

CarboPac PA-100 Guard Column (4 x 50 mm)ThermoFisher Scientific

Dionex Cat # 043054

01No.

52.

CarboPac PA-100 Preparative Column (22 x 250 mm)ThermoFisher Scientific

Dionex Cat # SP2667

01No.

53. Resource Q GE Healthcare Cat # GE17-1179-01 02Nos.

54.HiTrap® Heparin High Performance (5/pkt)GE Healthcare Cat # GE 17-0407-03

01pkt

55.

HiTrap® Phenyl Fast Flow (HS) (5/pkt)GE Healthcare Cat # GE 17-5193-01

01pkt

Sr# Name of Items Specifications Qty U Price Total Price

Page 21: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

56.Gel filtration column SuperdexTM

200 10/300 GLGE Healthcare Part # 17-5175-01

03Nos.

57.Gel filtration column SuperdexTM

75 10/300 GLGE Healthcare Part # 17-5174-01

02Nos.

58.PD-10 Desalting column GE Healthcare Codes Cat # GE17-0851-01

40-purifications

59. MicroSpinTM G-25 columns Cat # GE Healthcare 27-5325-01 01pkt

60.

Centrifuge tubes with screw capped lids (Beckman coulter) 50 mL (Autoclaveable), 100mL, 200 mL, 1000 mL Polycarbonate,

12 tubes.

61.

Centrifuge tubes screw capped lids (Beckman coulter) 50 mL (Autoclaveable), 100mL, 200 mL, 1000 mL Polypropylene,

12 tubes.

62.

Centrifuge tubes screw capped lids (Beckman coulter) 50 mL (Autoclaveable), 100mL, 200 mL, 1000 mL Teflon,

12 tubes.

63. Oil for vacuum pumps (freeze driers) Pfeiffer P3 Oil 10Ltr

64. Thin Layer Chromatography Chambers 02Nos.

65.Slide-a-Lyzer Dialysis cassette 3500 MWCO, 0.5 – 3 ml capacity,Thermo scientific Cat # 66330-,

01pack

66. Sep-Pak Cartridges Classic C18 – Waters part no: WAT051910 01pack

67. Oasis PLUS HLB – cartridges – Waters part no: 186000132 01pack

68.

Dowex resin (50Wx8 (Hydrogen form, 50–100 mesh)Sigma Aldrich-Merck Cat # 217492-

01x100gm

69.Poly (acrylic acid sodium salt) Sigma Aldrich-Merck Cat # 447013-100G

01x100gm

70. Glucopon 600 (G600) Sigma Aldrich-Merck Cat # 49122 01 pack

71.Pierce™ Protein Concentrator, Cat # 88527, PES, 10K MWCO, 5-20 mL, 10 reactions

01pkt

Page 22: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

Sr# Name of Items Specifications Qty U Price Total Price

72.Pierce™ Protein Concentrator, Cat # 88529, PES, 30K MWCO, 5-20 mL, 10 reactions

01pkt

73.Vivaspin 2 centrifugal concentratorsCut off size 3 and 10 kDa (100/pkt)

01pkt each

74. Thin layer chromatography Silica gel plates 05pkts

75. Hi prep 16/60 Sephacrly. S-200 HR Column Cat # 17-1166-01 01x120ml

(B) Accessories/Spare parts for HPLC, SYKAM-Germany:Sr# Name of Items Specifications Qty U Price Total Price

01. Pressure Sensor required for Pump Model: S1121 02Nos.

02. Relief Valve required for Pump Model: S1121 02Nos.

03. D2 Lamp required for UV-VIS Detector: Model S3210 03Nos.

04. Stainless Steel tubing 02Meter05. Stainless Steel Fittings and Ferrules 10each06. Check Valve cartridges for Pump 05Nos.07. Piston for pump (analytical) 04Nos.

08. Primary and Secondary seals for Pump 08Nos.

09. PTFE sealing and quartz lens for flow cell of UV-Vis Detector 04sets

10. Peek Fittings 10Nos.(C) Accessories for FPLC AKTA system GE/Amersham BiosciencesSr# Name of Items Specifications Qty U Price Total Price01. D2 UV lamp for UV-900 03Nos.

02.Pump required for model P-900, flow rate 100 ml/min for AKTA purifier

02Nos.

03.Pump required for model P-900, flow rate 10 ml/min for AKTA Explorer

02Nos.

04.Pistons required for Pump Model: P-900 Flow rate 100ml/min for AKTA purified

02Nos.

05. Pistons required for pump Model P-900

02Nos.

06. Reference Fiber OPTIC 02Nos.07. Sample Fiber OPTIC 02Nos.08. V Injection Value for INV 907 01No.

Page 23: pu.edu.pkpu.edu.pk/images/image/Tender-Notices/Tender_Documents-SBS.docx · Web viewpu.edu.pk

Sr# Name of Items Specifications Qty U Price Total Price

09. Cog belt for Pump P 900 flow 100ml/min

02Nos.

10. Resistant starch assay kit Megazayme cat # K-RSTAR

01kit

11. Total Starch Assay kit Megazayme Cat # K-TSTA-100 A

01kit

Director GeneralSchool of Biological Sciences,

University of the Punjab,New Campus, Lahore.

1.2 Date of Submission & Opening:Receipt of tenders: 02, April 2019 till 01:00PMOpening Tender’s 02, April 2019 at 02:30PM in School of Biological Sciences,

University of the Punjab, Lahore.1.3 Particulars of Firms:

Name & Postal Address of Firm:______________________________________

______________________________________

______________________________________ Signature: ____________________________________

______________________________________ Name: ____________________________________

______________________________________ Desg: ____________________________________

Tele No:____________Fax No.____________ Cell No. ____________________________________

NTN: _______________________________ Stamp: ____________________________________

GST: _______________________________

E-mail: _______________________________