1 of 12 FEATURES INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC'S success in “IMPROVING POWER BY DESIGN.” But it doesn't stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%. TEST CRITERIA: PROTOTYPE TESTED NEMA MG1-22 EVALUATION SYSTEM TORSIONALTESTED MOTOR STARTING ABILITY SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. TRUE POWER™ ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVAC systems. GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. ® INCLUDES: Two Line LCD Multilingual Digital Evolution™ Controller (English/Spanish/ French/Portuguese) with external viewing window for easy indication of generator status and breaker position. Isochronous Electronic Governor Sound Attenuated Aluminum Enclosure Smart Battery Charger UV / Ozone Resistant Hoses ±1% Voltage Regulation Five Year Limited Warranty ® Diesel Generator Set Protector™ Series Not for sale in US/CA Standby Power Rating Model RD015 - 15 kW 60 Hz Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz Model RD048 - 48 kW 60 Hz (single phase only) Model RD050 - 50 kW 60 Hz (three phase only) Protector™ *Assembled in the USA using domestic and foreign parts

Upload: dominh

Post on 15-Aug-2019

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Protector™ Series Diesel Generator Set · Isochronous Electronic Governor Sound Attenuated Aluminum Enclosure Smart Battery Charger UV / Ozone Resistant Hoses ±1% Voltage Regulation

1 of 12

FEATURES

INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC'Ssuccess in “IMPROVING POWER BY DESIGN.” But it doesn't stop there. Totalcommitment to component testing, reliability testing, environmental testing,destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and otherstandards, allows you to choose GENERAC POWER SYSTEMS with the confidencethat these systems will provide superior performance.

SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on allGenerac models. It provides optimized FAST RESPONSE to changing loadconditions and MAXIMUM MOTOR STARTING CAPABILITY by electronicallytorque-matching the surge loads to the engine. Digital voltage regulation at±1%.

TEST CRITERIA:

√ PROTOTYPE TESTED √ NEMA MG1-22 EVALUATION √ SYSTEM TORSIONALTESTED √ MOTOR STARTING ABILITY

SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealernetwork provides parts and service know-how for the entire unit, from the engineto the smallest electronic component.

TRUE POWER™ ELECTRICAL TECHNOLOGY: Superior harmonics and sine waveform produce less than 5% Total Harmonic Distortion for utility quality power. This allowsconfident operation of sensitive electronic equipment and micro-chip based appliances,such as variable speed HVAC systems.

GENERAC TRANSFER SWITCHES: Long life and reliability are synonymouswith GENERAC POWER SYSTEMS. One reason for this confidence is that theGENERAC product line includes its own transfer systems and controls for totalsystem compatibility.

®

INCLUDES: Two Line LCD Multilingual Digital

Evolution™ Controller (English/Spanish/ French/Portuguese) with external viewing window for easy indication of generator status and breaker position.

Isochronous Electronic Governor Sound Attenuated Aluminum Enclosure Smart Battery Charger UV / Ozone Resistant Hoses ±1% Voltage Regulation Five Year Limited Warranty

®

Diesel Generator SetProtector™

Series

Not for sale in US/CA

Standby Power Rating

Model RD015 - 15 kW 60 HzModel RD020 - 20 kW 60 HzModel RD030 - 30 kW 60 Hz

Model RD048 - 48 kW 60 Hz (single phase only)Model RD050 - 50 kW 60 Hz (three phase only)

Prot

ecto

r™

*Assembled in the USA using domestic and foreign parts

Page 2: Protector™ Series Diesel Generator Set · Isochronous Electronic Governor Sound Attenuated Aluminum Enclosure Smart Battery Charger UV / Ozone Resistant Hoses ±1% Voltage Regulation

2 of 12

15 • 20 • 30 • 48 • 50 kW application and engineering data

®

Prot

ecto

r™

GENERATOR SPECIFICATIONS

Type Synchronous

Rotor Insulation Class H (15 & 20 kW) or F (30, 48, & 50 kW)

Stator Insulation Class H

Telephone Interference Factor (TIF) <50

Alternator Output Leads 1-Phase Three wire

Alternator Output Leads 3-Phase Six wire

Bearings Single Sealed Cartridge

Coupling Direct, Flexible Disc

Excitation System Direct

Total Harmonic Distortion < 5%

VOLTAGE REGULATION

Type Electronic

Sensing Single Phase

Regulation ± 1%

Features Adjustable Voltage & Gain

GOVERNOR SPECIFICATIONS

Type Electronic Isochronous

Steady State Regulation ± 0.25%

ELECTRICAL SYSTEM

Battery Charge Alternator 50 Amp (15 & 20 kW), 65 Amp (30 kW), or 70 Amp (48 & 50 kW)

Static Battery Charger 2 Amp

Recommended Battery (battery not included)Group 27F, 700CCA*

*Group 31, 925CCA batteries can also be used with the 30kW

System Voltage 12 Volts

ALTERNATOR SPECIFICATIONS

Revolving field heavy duty generatorDirectly connected to the engineOperating temperature rise 120°C above a 40°C ambient Class H insulation is NEMA ratedClass F insulation is NEMA rated All models fully prototype tested

ENCLOSURE FEATURES

Aluminum weather protective enclosureEnsures protection against mother nature. Electrostatically applied textured epoxy paint for added durability.

Enclosed critical grade mufflerQuiet, critical grade muffler is mounted inside the unit to prevent injuries and maximize sound dampening.

Small, compact, attractive Makes for an easy, eye appealing installation.

SAE Sound attenuated enclosure ensures quiet operation.

Page 3: Protector™ Series Diesel Generator Set · Isochronous Electronic Governor Sound Attenuated Aluminum Enclosure Smart Battery Charger UV / Ozone Resistant Hoses ±1% Voltage Regulation

of 12

®

Prot

ecto

r™

3

15 • 20 • 30 • 48 • 50 kW application and engineering data

ENGINE SPECIFICATIONS: 15 & 20 KWMake Mitsubishi

Model In-line

Cylinders 4

Displacement (Liters) 2.505

Bore (in / mm) 3.46 / 88

Stroke (in / mm) 4.06 / 103

Compression Ratio 22:1

Intake Air System Naturally Aspirated

Cylinder Head Type Cast Iron OHV

Piston Type Aluminum

ENGINE SPECIFICATIONS: 30 KWMake Perkins

Model In-line

Cylinders 4

Displacement (Liters) 2.216

Bore (in / mm) 3.30 / 84

Stroke (in / mm) 3.94 / 100

Compression Ratio 23.3:1

Intake Air System Turbocharged / Aftercooled

Cylinder Head Type Cast Iron OHV

Piston Type Aluminum

ENGINE SPECIFICATIONS: 48 & 50 KWMake Generac

Model In-line

Cylinders 4

Displacement (Liters) 3.4

Bore (in / mm) 3.86 / 98

Stroke (in / mm) 4.45 / 113

Compression Ratio 18.5:1

Intake Air System Turbocharged / Aftercooled

Cylinder Head Type Cast Iron OHV

Piston Type Aluminum

ENGINE LUBRICATION SYSTEM

Oil Pump Type Gear

Oil Filter Type Full flow spin-on canister

Crankcase Capacity (quarts / liters)6.87 / 6.5 - 15 & 20 kW11.2 / 10.6 - 30 kW7.4 / 7 – 48 & 50 kW

FUEL SYSTEM

Fuel Type Ultra Low Sulfur Diesel Fuel

Fuel Pump Type Mechanical Engine Driven Gear

Injector Type Mechanical

Fuel Supply Line (mm / in) 7.94 / 0.31 (ID)

Fuel Return Line (mm / in)N/A - 15 & 20 kW4.76 / 0.19 (ID) - 30 kW7.94 / 7 (ID) - 48 & 50 kW

Fuel Specification ASTM

Fuel Filtering (microns)6 - 15 & 20 kW25 - 30 kW10 - 48 & 50 kW

ENGINE COOLING SYSTEM

Water Pump Pre-lubed, self-sealing

Fan Speed (rpm)2376 - 15 & 20 kW1980 - 30 kW2029 - 48 & 50 kW

Fan Diameter (in / mm)18.11 / 460 (15 & 20 kW)18 / 457.2 (30 kW)22 / 559 (48 & 50 kW)

Fan Mode Pusher

TANK SPECIFICATIONS

Total Size (gallons/liters)45 / 170.3 - 15 & 20 kW68 / 257.4 - 30, 48, & 50 kW

Usable Size (gallons/liters)40 / 151.4 - 15 & 20 kW61 / 230.9 - 30, 48, & 50 kW

Run Time @ 1/2 Load (hrs)

48.7 - 15 kW38.8 - 20 kW44.5 - 30 kW26.5 - 48 & 50 kW

WEIGHTS AND DIMENSIONS

Model Weight (lb / kg)Dimensions (L x W x H)(in / cm)

15 kW 1372 / 622 62 x 31 x 49 / 158 x 78 x 124

20 kW 1372 / 622 62 x 31 x 49 / 158 x 78 x 124

30 kW 1726 / 783 77 x 35 x 57 / 195 x 89 x 147

48 & 50 kW 1953 / 886 77 x 35 x 55 / 195 x 89 x 141

Page 4: Protector™ Series Diesel Generator Set · Isochronous Electronic Governor Sound Attenuated Aluminum Enclosure Smart Battery Charger UV / Ozone Resistant Hoses ±1% Voltage Regulation

4 of 12

®

Prot

ecto

r™

15 • 20 • 30 • 48 • 50 kW application and engineering data

GENERATOR OUTPUT VOLTAGE / KW–60 HZ

kW (standby) Amp (standby) kW (Prime) Amp (Prime) CB Size

RD015120/240 V, 1Ø, 1.0 pf 15 62 12 50 70120/208 V, 3Ø, 0.8 pf 15 52 12 42 60120/240 V, 3Ø, 0.8 pf 15 45 12 36 50

RD020120/240 V, 1Ø, 1.0 pf 20 83 16 67 100120/208 V, 3Ø, 0.8 pf 20 69 16 56 80120/240 V, 3Ø, 0.8 pf 20 60 16 48 70

RD030

120/240 V, 1Ø, 1.0 pf 30 125 24 100 150120/208 V, 3Ø, 0.8 pf 30 104 24 83 125120/240 V, 3Ø, 0.8 pf 30 90 24 72 100277/480 V, 3Ø, 0.8 pf 30 45 24 36 50

RD048RD050

120/240 V, 1Ø, 1.0 pf 48 200 38.4 183 200120/208 V, 3Ø, 0.8 pf 50 173 40 153 200120/240 V, 3Ø, 0.8 pf 50 150 40 132 175277/480 V, 3Ø, 0.8 pf 50 75 40 66 90

SURGE CAPACITY IN AMPS

Voltage Dip @ < 0.4 pf 15% 30%

RD015120/240 V, 1Ø 53 129120/208 V, 3Ø 37 90120/240 V, 3Ø 32 78

RD020120/240 V, 1Ø 87 211120/208 V, 3Ø 59 143120/240 V, 3Ø 51 124

RD030

120/240 V, 1Ø 66 168120/208 V, 3Ø 59 144120/240 V, 3Ø 51 125277/480 V, 3Ø 26 64

RD048RD050

120/240 V, 1Ø 69 189120/208 V, 3Ø 90 218120/240 V, 3Ø 78 189277/480 V, 3Ø 36 87

ENGINE FUEL CONSUMPTION

gal/hr L/hr

RD015

25% of rated load 0.60 2.2750% of rated load 0.85 3.2275% of rated load 1.10 4.16100% of rated load 1.46 5.53

RD020

25% of rated load 0.77 2.950% of rated load 1.03 3.9075% of rated load 1.46 5.53100% of rated load 1.97 7.46

RD030

25% of rated load 0.97 3.6750% of rated load 1.37 5.1975% of rated load 1.97 7.46100% of rated load 2.77 10.49

RD048RD050

25% of rated load 1.35 5.1150% of rated load 2.15 8.1475% of rated load 3.06 11.58100% of rated load 3.98 15.07

Page 5: Protector™ Series Diesel Generator Set · Isochronous Electronic Governor Sound Attenuated Aluminum Enclosure Smart Battery Charger UV / Ozone Resistant Hoses ±1% Voltage Regulation

5 of 12

Prot

ecto

r™

15 • 20 • 30 • 48 • 50 kW operating data

®

POWER ADJUSTMENT FOR AMBIENT CONDITIONSTemperature Deration ...................................................................................................................3% for every 5 °C above 25 °C or 1.7% for every 5 °F above 77 °FAltitude Deration (15, 30, 48 & 50 kW)................................................................................1% for every 100 m above 915 m or 3% for every 1000 ft above 3000 ftAltitude Deration (20 kW) ....................................................................................................1% for every 100 m above 305 m or 3% for every 1000 ft above 1000 ft

CONTROLLER FEATURES2-Line Plain Text Multilingual LCD Display ..................................................................................................................... Simple user interface for ease of operation.Mode Buttons: Auto....................................................................................................................Automatic Start on Utility failure. Programmable 7 day exerciser.

Manual ...................................................................................... Start with starter control, unit stays on. If utility fails, transfer to load takes place.Off .......................................................................................................................Stops unit. Power is removed. Control and charger still operate.

Ready to Run/Maintenance Message. ................................................................................................................................................................................ StandardEngine Run Hours Indication...............................................................................................................................................................................................StandardProgrammable start delay between 2-1500 seconds ...................................................................................... Five seconds standard (programmable by dealer only)Utility Voltage Loss/Return to Utility Adjustable..................................................................................................................................... From 140-171 V/190-216 VFuture Set Capable Exerciser/Exercise Set Error Warning ....................................................................................................................................................StandardRun/Alarm/Maintenance Logs................................................................................................................................................................................... 50 Events EachEngine Start Sequence ......................................................................................................................Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration)Starter Lock-out ......................................................................................................................... Starter cannot re-engage until 5 seconds after engine has stopped.Smart Battery Charger ........................................................................................................................................................................................................StandardCharger Fault/Missing AC Warning .....................................................................................................................................................................................StandardLow Battery/Battery Problem Protection and Battery Condition Indication.............................................................................................................................StandardAutomatic Voltage Regulation with Over and Under Voltage Protection ................................................................................................................................StandardUnder-Frequency/Overload/Stepper Overcurrent Protection.................................................................................................................................................StandardSafety Fused/Fuse Problem Protection................................................................................................................................................................................StandardAutomatic Low Oil Pressure Shutdown................................................................................................................................................................................StandardOvercrank/Overspeed (@ 72 Hz)/RPM Sense Loss Shutdown.............................................................................................................................................StandardHigh Engine Temperature Shutdown .................................................................................................................................................................................. StandardInternal Fault/Incorrect Wiring Protection ........................................................................................................................................................................... StandardCommon External Fault Capability ......................................................................................................................................................................................StandardField Upgradeable Firmware ...............................................................................................................................................................................................StandardLow Coolant Level Shutdown..............................................................................................................................................................................................StandardAuxiliary Shutdown.............................................................................................................................................................................................................Standard

ENGINE COOLING

15 kW 20 kW 30 kW 48 & 50 kW

Air flow (inlet air including alternator and combustion air in cfm/cmm) 2750 / 78 2750 / 78 2800 / 79 2824 / 80System coolant capacity (gal/liters) 3.0 / 11.4 3.0 / 11.4 2.5 / 9.5 2.8 / 10.6Heat rejection to coolant (BTU per hr/MJ per hr) 95,220 / 100.5 95,220 / 100.5 128,638 / 135.7 135,900 / 143.4Maximum operation air temperature on radiator (°C/°F) 50 / 122Maximum ambient temperature (°C/°F) 50 / 122

COMBUSTION REQUIREMENTSFlow at rated power (cfm / cmm) 86.3 / 2.4 86.3 / 2.4 88 / 2.5 190 / 5.38

SOUND EMISSIONSSound output in dB(A) at 23 ft (7 m) with generator in exercise mode* 65Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load* 70

EXHAUSTExhaust flow at rated output (cfm/cmm) 98.88 / 2.8 98.88 / 2.8 296.6 / 8.4 448 / 12.7Exhaust temperature at rated output (°C/°F) 482 / 900 482 / 900 499 / 930 604.4 / 1120

ENGINE PARAMETERSRated Synchronous RPM 1800HP at rated kW 26.4 33.5 49 85

Page 6: Protector™ Series Diesel Generator Set · Isochronous Electronic Governor Sound Attenuated Aluminum Enclosure Smart Battery Charger UV / Ozone Resistant Hoses ±1% Voltage Regulation

6 of 12

Prot

ecto

r™

15 • 20 kW installation layout

®

D2.5L G2 Single Wall (1 of 2)

43

21

43

1

AB

AB

182

[7.2

]10

65[4

1.9]

1582

[62.

3]O

VE

RA

LL L

EN

GTH

1238

[48.

7]O

VE

RA

LL

HE

IGH

T

776

[30.

6]O

VE

RA

LL W

IDTH

303

[11.

9]

631

[24.

8]D

OO

R T

YP

110

[4.3

]

212

[8.4

]

739

[29.

1]C

EN

TER

OF

GR

AV

ITY

WE

IGH

T D

ATA

WIT

H E

MP

TY B

AS

ETA

NK

(SE

E N

OTE

5)

GE

NE

RA

TOR

AS

SH

OW

N62

2 [1

372]

WIT

H W

OO

DE

N S

HIP

PIN

G S

KID

661

[145

7]

SE

RV

ICE

ITE

M2.

5LO

IL F

ILL

CA

PR

IGH

T S

IDE

OIL

DIP

STI

CK

RIG

HT

SID

EO

IL F

ILTE

RR

IGH

T S

IDE

OIL

DR

AIN

HO

SE

LEFT

SID

ER

AD

IATO

R D

RA

IN H

OS

ELE

FT S

IDE

CO

OLA

NT

RE

CO

VE

RY

BO

TTLE

LEFT

SID

ER

AD

IATO

R F

ILL

CA

P A

CC

ES

SR

OO

FA

IR C

LEA

NE

R E

LEM

EN

TLE

FT S

IDE

MU

FFLE

RFR

ON

TFA

N B

ELT

EIT

HE

R S

IDE

BA

TTE

RY

LEFT

SID

E

TIT

LE

INS

TALL

PR

OTE

CTO

R D

2.5L

G2

SIN

GLE

WA

LL T

AN

K

ISSU

E D

ATE:

06/2

017

SIZ

EC

AG

E N

OD

WG

NO

1000

0022

175

RE

V

BN

/A

ASC

ALE

0.05

0 W

T-K

GS

EE

AB

OV

ES

HE

ET

1 of

2

GE

NE

RA

C P

OW

ER

SY

STE

MS

OW

NS

TH

E C

OP

YR

IGH

T O

F TH

IS D

RA

WIN

GW

HIC

H IS

SU

PP

LIE

D IN

CO

NFI

DE

NC

E A

ND

MU

ST

NO

T B

E U

SE

D F

OR

AN

Y P

UR

PO

SE

OTH

ER

TH

AN

FO

R W

HIC

H IT

IS S

UP

PLI

ED

WIT

HO

UT

THE

EX

PR

ES

S W

RIT

TEN

CO

NS

EN

T O

F G

EN

ER

AC

PO

WE

R S

YS

TEM

S.

c G

EN

ER

AC

PO

WE

R S

YS

TEM

S 2

013

ELEC

TRO

NIC

ALLY

APP

RO

VED

INSI

DE

WIN

DC

HIL

L

DR

AWIN

G C

REA

TED

FR

OM

PR

O/E

NG

INEE

R3D

FIL

E. E

CO

MO

DIF

ICAT

ION

TO

BE

APPL

IED

TO

SO

LID

MO

DEL

ON

LY.

SH

1/2

REV

AW

INDC

HILL

VER

SION

A.4

NO

TES

: 1.

MIN

IMU

M R

EC

OM

ME

ND

ED

CO

NC

RE

TE P

AD

SIZ

E: 1

092

(43"

) WID

E X

188

7 (7

4.3"

) LO

NG

. R

EFE

RE

NC

E IN

STA

LLA

TIO

N G

UID

E S

UP

PLI

ED

WIT

H U

NIT

FO

R C

ON

CR

ETE

PA

D G

UID

ELI

NE

S.

2. A

LLO

W S

UFF

ICIE

NT

RO

OM

ON

ALL

SID

ES

OF

THE

GE

NE

RA

TOR

FO

R M

AIN

TEN

AN

CE

AN

D S

ER

VIC

ING

. TH

IS U

NIT

MU

ST

BE

INS

TALL

ED

IN A

CC

OR

DA

NC

E W

ITH

CU

RR

EN

T A

PP

LIC

AB

LE N

FPA

37

AN

D N

FPA

70

STA

ND

AR

DS

AS

WE

LL A

S A

NY

OTH

ER

FE

DE

RA

L, S

TATE

, AN

D L

OC

AL

CO

DE

S.

3. C

ON

TRO

L P

AN

EL

/ CIR

CU

IT B

RE

AK

ER

INFO

RM

ATI

ON

: -

SE

E S

PE

CIF

ICA

TIO

N S

HE

ET

OR

OW

NE

RS

MA

NU

AL

- A

CC

ES

SIB

LE T

HR

OU

GH

CU

STO

ME

R A

CC

ES

S A

SS

EM

BLY

DO

OR

ON

RE

AR

OF

GE

NE

RA

TOR

.4.

RE

MO

VE

TH

E R

EA

R S

TUB

-UP

AN

D R

EA

R E

NC

LOS

UR

E C

OV

ER

PA

NE

L TO

AC

CE

SS

TH

E S

TUB

-UP

AR

EA

S A

S F

OLL

OW

S:

- H

IGH

VO

LTA

GE

CO

NN

EC

TIO

N IN

CLU

DIN

G A

C L

OA

D L

EA

D C

ON

DU

IT C

ON

NE

CTI

ON

,

NE

UTR

AL

CO

NN

EC

TIO

N, A

ND

BA

TTE

RY

CH

AR

GE

R 1

20 V

OLT

AC

(0.5

AM

P M

AX

) CO

NN

EC

TIO

N.

- L

OW

VO

LTA

GE

CO

NN

EC

TIO

N IN

CLU

DIN

G T

RA

NS

FER

SW

ITC

H C

ON

TRO

L W

IRE

S

AN

D A

CC

ES

SO

RY

RE

LAY

CO

NN

EC

TIO

N (Q

TY 4

)5.

CE

NTE

R O

F G

RA

VIT

Y A

ND

WE

IGH

T M

AY

CH

AN

GE

DU

E T

O U

NIT

OP

TIO

NS

.6.

BO

TTO

M O

F G

EN

ER

ATO

R S

ET

MU

ST

BE

EN

CLO

SE

D T

O P

RE

VE

NT

PE

ST

INTR

US

ION

AN

D R

EC

IRC

ULA

TIO

N O

F D

ISC

HA

RG

E A

IR A

ND

/OR

IMP

RO

PE

R C

OO

LIN

G A

IR F

LOW

.7.

RE

FER

EN

CE

OW

NE

RS

MA

NU

AL

FOR

LIF

TIN

G W

AR

NIN

GS

.8.

MO

UN

TIN

G B

OLT

S O

R S

TUD

S T

O M

OU

NTI

NG

SU

RFA

CE

SH

ALL

BE

5/8

-11

GR

AD

E 5

(U

SE

STA

ND

AR

D S

AE

TO

RQ

UE

SP

EC

S)

9. M

US

T A

LLO

W F

RE

E F

LOW

OF

INTA

KE

AIR

, DIS

CH

AR

GE

AIR

AN

D E

XH

AU

ST.

SE

E S

PE

C S

HE

ET

FOR

MIN

IMU

M A

IR F

LOW

AN

D M

AX

IMU

M R

ES

TRIC

TIO

N R

EQ

UIR

EM

EN

TS.

10. G

EN

ER

ATO

R M

US

T B

E IN

STA

LLE

D S

UC

H T

HA

T FR

ES

H C

OO

LIN

G A

IR IS

AV

AIL

AB

LE A

ND

TH

AT

DIS

CH

AR

GE

AIR

FR

OM

RA

DIA

TOR

IS N

OT

RE

CIR

CU

LATE

D.

WE

IGH

T: K

G [L

BS

]D

IME

NS

ION

S: M

M [I

NC

H]

RE

FER

EN

CE

OW

NE

RS

MA

NU

AL

FOR

PE

RIO

DIC

RE

PLA

CE

ME

NT

PA

RT

LIS

TIN

GS

RA

DIA

TOR

/EX

HA

US

TD

ISC

HA

RG

E A

IR

RE

AR

VIE

W

RE

AR

EN

CLO

SU

RE

C

OV

ER

PA

NE

LS

EE

NO

TE 4

CIR

CU

IT B

RE

AK

ER

S

EE

NO

TE 3

CU

STO

ME

R A

CC

ES

S

AS

SE

MB

LY, C

ON

TRO

L P

AN

EL

AC

CE

SS

, B

ATT

ER

Y C

HA

RG

ER

LO

CA

TED

WIT

HIN

S

EE

NO

TE 4

RE

MO

VA

BLE

S

TUB

-UP

CO

VE

RS

EE

NO

TE 4

RIG

HT

SID

E V

IEW

SID

E O

F G

EN

ER

ATO

R L

IFT-

OFF

DO

OR

PE

R O

NE

PE

R D

OO

R, O

NE

VIS

E A

CTI

ON

LA

TCH

,

LIFT

ING

PR

OV

ISIO

N (4

PLA

CE

S)

SE

E N

OTE

S 5

, 7 A

ND

CE

NTE

R

OF

GR

AV

ITY

DIM

EN

SIO

NS

EN

CLO

SU

RE

PA

NE

L M

US

T B

E

RE

MO

VE

D T

O F

AC

ILIT

ATE

B

ATT

ER

Y IN

STA

LLA

TIO

N A

ND

R

EM

OV

AL

LEFT

SID

E V

IEW

EX

HA

US

T M

UFF

LER

E

NC

LOS

ED

WIT

HIN

G

EN

ER

ATO

R E

NC

LOS

UR

E

RA

DIA

TOR

/EX

HA

US

TD

ISC

HA

RG

E A

IR

OP

EN

PU

NC

HE

D L

OU

VE

RS

TY

PIC

AL

ON

BO

TH S

IDE

S O

F FU

EL

TAN

K

VE

NTI

LATI

ON

DU

CT

TO P

RO

VID

E

AD

EQ

UA

TE C

RO

SS

-FLO

W O

F A

IR

VE

NTI

LATI

ON

AIR

INTA

KE

(BO

TH S

IDE

S)

RA

DIA

TOR

/EX

HA

US

TD

ISC

HA

RG

E A

IR(B

OTH

SID

ES

)

BA

TTE

RY

12

VO

LT

NE

GA

TIV

E G

RO

UN

D

TOP

VIE

W

RE

MO

VE

CO

VE

R F

OR

A

CC

ES

S T

O R

AD

IATO

R

FILL

CA

P

2" O

.D.

EX

HA

US

T O

UTL

ET

Page 7: Protector™ Series Diesel Generator Set · Isochronous Electronic Governor Sound Attenuated Aluminum Enclosure Smart Battery Charger UV / Ozone Resistant Hoses ±1% Voltage Regulation

7 of 12

®

Prot

ecto

r™

D2.5L G2 Single Wall (2 of 2)

43

21

43

1

AB

AB

776

[30.

6]

739

[29.

1]M

OU

NTI

NG

CE

NTE

RS

TYP

354

[13.

9]

738

[29.

1]

19 [.7]

251

[9.9

]FU

EL

TAN

KH

EIG

HT

112

[4.4

]TY

P79

2[3

1.2]

TYP

1472

[57.

9]TY

P

1584

[62.

4]

51 [2.0

]

9 [.4]

105

[4.1

]*S

TUB

-UP

AR

EA

674

[26.

5]

1347

[53.

0]

40[1

.6]

100

[3.9

]*S

TUB

-UP

AR

EA

224

[8.8

]

625

[24.

6]TY

P

851

[33.

5]

446

[17.

5]

787

[31.

0]

1008

[39.

7]

1120

[44.

1]

151

[5.9

]

691

[27.

2]

FUE

L TA

NK

TO

TAL

CA

PA

CIT

Y

169

[44]

U

SA

BLE

CA

PA

CIT

Y

151

[40]

TIT

LE

INS

TALL

PR

OTE

CTO

R D

2.5L

G2

SIN

GLE

WA

LL T

AN

K

ISSU

E D

ATE:

06/2

017

SIZ

EC

AG

E N

OD

WG

NO

1000

0022

175

RE

V

BN

/A

ASC

ALE

0.08

0 W

T-K

GS

EE

AB

OV

ES

HE

ET

2 of

2

GE

NE

RA

C P

OW

ER

SY

STE

MS

OW

NS

TH

E C

OP

YR

IGH

T O

F TH

IS D

RA

WIN

GW

HIC

H IS

SU

PP

LIE

D IN

CO

NFI

DE

NC

E A

ND

MU

ST

NO

T B

E U

SE

D F

OR

AN

Y P

UR

PO

SE

OTH

ER

TH

AN

FO

R W

HIC

H IT

IS S

UP

PLI

ED

WIT

HO

UT

THE

EX

PR

ES

S W

RIT

TEN

CO

NS

EN

T O

F G

EN

ER

AC

PO

WE

R S

YS

TEM

S.

c G

EN

ER

AC

PO

WE

R S

YS

TEM

S 2

013

ELEC

TRO

NIC

ALLY

APP

RO

VED

INSI

DE

WIN

DC

HIL

L

DR

AWIN

G C

REA

TED

FR

OM

PR

O/E

NG

INEE

R3D

FIL

E. E

CO

MO

DIF

ICAT

ION

TO

BE

APPL

IED

TO

SO

LID

MO

DEL

ON

LY.

SH

2/2

REV

AW

INDC

HILL

VER

SION

A.4

CA

PA

CIT

Y: L

ITE

R [G

ALL

ON

]D

IME

NS

ION

S: M

M [I

NC

H]

*NO

TE: S

TUB

-UP

AR

EA

FO

R H

IGH

A

ND

LO

W V

OLT

AG

E C

ON

NE

CTI

ON

S,

CIR

CU

IT B

RE

AK

ER

, NE

UTR

AL

AN

D

CU

STO

ME

R C

ON

NE

CTI

ON

OP

EN

ING

.

LEFT

SID

E V

IEW

RE

MO

VA

BLE

CO

VE

R

HIG

H A

ND

LO

W

VO

LTA

GE

STU

B-U

P A

RE

A

TOP

VIE

W

FUE

L S

UP

PLY

NO

RM

AL

VE

NT

(2" N

PT

FEM

ALE

)

EM

ER

GE

NC

Y V

EN

T(2

" NP

T FE

MA

LE)

FUE

L LE

VE

L G

AU

GE

/SE

ND

ER

FUE

L FI

LL(2

" NP

T FE

MA

LE)

16.6

6 [0

.66]

MO

UN

TIN

G H

OLE

S(6

PLA

CE

S)

SE

E N

OTE

8

RE

MO

VA

BLE

STU

B-U

P

CO

VE

RS

EE

NO

TE 4

RE

AR

VIE

W

15 • 20 kW installation layout

Page 8: Protector™ Series Diesel Generator Set · Isochronous Electronic Governor Sound Attenuated Aluminum Enclosure Smart Battery Charger UV / Ozone Resistant Hoses ±1% Voltage Regulation

8 of 12

30 kW installation layout

®

Prot

ecto

r™

D2.2L G22 Single Wall (1 of 2)

43

21

43

1

AB

AB

888

[35.

0]O

VER

ALL

WID

TH

1452

[57.

2]O

VER

ALL

HEI

GH

T

1954

[76.

9]O

VER

ALL

LEN

GTH

182

[7.2

]TY

P

324

[12.

7]TY

P

1322

[52.

0]TY

P

897

[35.

3]D

OO

R W

IDTH

TYP

173

[6.8

]EX

HAU

STO

UTL

ET

146

[5.8

]EX

HAU

STO

UTL

ET

874

[34.

4]C

ENTE

R O

F G

RAV

ITY

SER

VIC

E IT

EM2.

2LO

IL F

ILL

CAP

RIG

HT

SID

EO

IL D

IP S

TIC

KR

IGH

T SI

DE

OIL

FIL

TER

RIG

HT

SID

EO

IL D

RAI

N H

OSE

RIG

HT

SID

ER

ADIA

TOR

DR

AIN

HO

SELE

FT S

IDE

CO

OLA

NT

REC

OVE

RY

BOTT

LELE

FT S

IDE

RAD

IATO

R F

ILL

CAP

AC

CES

SR

OO

FAI

R C

LEAN

ER E

LEM

ENT

RIG

HT

SID

EM

UFF

LER

FRO

NT

SID

EFA

N B

ELT

EITH

ER S

IDE

BATT

ERY

LEFT

SID

E

WEI

GH

T D

ATA

WIT

H E

MPT

Y BA

SETA

NK

(SEE

NO

TE 5

)

GEN

ERAT

OR

AS

SHO

WN

783

[172

6]W

ITH

WO

OD

EN S

HIP

PIN

G S

KID

819

[180

6]

TIT

LE

INST

ALL

PRO

TEC

TOR

D2.

2L G

22SI

NG

LE W

ALL

TAN

K

ISSU

E DA

TE:

07/2

017

SIZ

EC

AG

E N

OD

WG

NO

1000

0018

294

RE

V

BN

/A

ASC

ALE

0.05

0 W

T-K

GS

EE

AB

OV

ES

HE

ET

1 of

2

GEN

ERAC

PO

WER

SYS

TEM

S O

WN

S TH

E C

OPY

RIG

HT

OF

THIS

DR

AWIN

GW

HIC

H IS

SU

PPLI

ED IN

CO

NFI

DEN

CE

AND

MU

ST N

OT

BE U

SED

FO

RAN

Y PU

RPO

SE O

THER

TH

AN F

OR

WH

ICH

IT IS

SU

PPLI

ED W

ITH

OU

T TH

E EX

PRES

S W

RIT

TEN

CO

NSE

NT

OF

GEN

ERAC

PO

WER

SYS

TEM

S.c

GEN

ERAC

PO

WER

SYS

TEM

S 20

13

ELEC

TRO

NICA

LLY

APPR

OVE

DIN

SIDE

WIN

DCHI

LL

DRAW

ING

CRE

ATED

FRO

M P

RO/E

NGIN

EER

3D F

ILE.

ECO

MO

DIFI

CATI

ON

TO B

E AP

PLIE

D TO

SO

LID

MO

DEL

ONL

Y.

SH

1/2

REV

AW

INDC

HILL

VER

SION

A.4

AIR

INTA

KE(B

OTH

SID

ES)

RAD

IATO

R/E

XHAU

ST

DIS

CH

ARG

E AI

R(B

OTH

SID

ES)

REF

EREN

CE

OW

NER

S M

ANU

AL F

OR

PE

RIO

DIC

REP

LAC

EMEN

T PA

RT

LIST

ING

S

NO

TES:

1. M

INIM

UM

REC

OM

MEN

DED

CO

NC

RET

E PA

D S

IZE:

119

4 (4

7") W

IDE

X 22

61 (8

9") L

ON

G.

REF

EREN

CE

INST

ALLA

TIO

N G

UID

E SU

PPLI

ED W

ITH

UN

IT F

OR

CO

NC

RET

E PA

D G

UID

ELIN

ES2.

ALL

OW

SU

FFIC

IEN

T R

OO

M O

N A

LL S

IDES

OF

THE

GEN

ERAT

OR

FO

R M

AIN

TEN

ANC

E A

ND

SER

VIC

ING

. TH

IS U

NIT

MU

ST B

E IN

STAL

LED

IN A

CC

OR

DAN

CE

WIT

H C

UR

REN

T A

PPLI

CAB

LE N

FPA

37 A

ND

NFP

A 70

STA

ND

ARD

S AS

WEL

L AS

AN

Y O

THER

FED

ERAL

, S

TATE

, AN

D L

OC

AL C

OD

ES.

3. C

ON

TRO

L PA

NEL

/ C

IRC

UIT

BR

EAKE

R IN

FOR

MAT

ION

: -

SEE

SPE

CIF

ICAT

ION

SH

EET

OR

OW

NER

S M

ANU

AL -

AC

CES

SIBL

E TH

RO

UG

H C

UST

OM

ER A

CC

ESS

ASSE

MBL

Y D

OO

R O

N R

EAR

OF

G

ENER

ATO

R4.

REM

OVE

TH

E R

EAR

TAN

K AN

D R

EAR

EN

CLO

SUR

E C

OVE

R P

ANEL

TO

AC

CES

S T

HE

STU

B-U

P AR

EAS

AS F

OLL

OW

S: -

HIG

H V

OLT

AGE

CO

NN

ECTI

ON

INC

LUD

ING

AC

LO

AD L

EAD

CO

ND

UIT

CO

NN

ECTI

ON

N

EUTR

AL C

ON

NEC

TIO

N, B

ATTE

RY

CH

ARG

ER 1

20 V

OLT

AC

(0.5

AM

P M

AX) C

ON

NEC

TIO

N.

- L

OW

VO

LTAG

E C

ON

NEC

TIO

NS

INC

LUD

ING

TR

ANSF

ER S

WIT

CH

CO

NTR

OL

WIR

ES5.

CEN

TER

OF

GR

AVIT

Y AN

D W

EIG

HT

MAY

CH

ANG

E D

UE

TO U

NIT

OPT

ION

S.6.

EN

GIN

E SE

RVI

CE

CO

NN

ECTI

ON

S

OIL

DR

AIN

: 3/8

" NPT

EX

HAU

ST O

UTL

ET: 2

" O.D

.7.

BO

TTO

M O

F G

ENER

ATO

R S

ET M

UST

BE

ENC

LOSE

D T

O P

REV

ENT

PEST

INTR

USI

ON

AN

D A

ND

REC

IRC

ULA

TIO

N O

F D

ISC

HAR

GE

AIR

AN

D/O

R IM

PRO

PER

CO

OLI

NG

AIR

FLO

W.

8. R

EFER

ENC

E O

WN

ERS

MAN

UAL

FO

R L

IFTI

NG

WAR

NIN

GS.

9. M

OU

NTI

NG

BO

LTS

OR

STU

DS

TO C

ON

CR

ETE

PAD

SH

ALL

BE 5

/8-1

1 G

RAD

E 5

(U

SE S

TAN

DAR

D S

AE T

OR

QU

E SP

ECS)

WEI

GH

T: K

G [L

BS]

DIM

ENSI

ON

S: M

M [I

NC

H]

RAD

IATO

R/E

XHAU

ST

DIS

CH

ARG

E AI

R

REA

R E

NC

LOSU

RE

CO

VER

PAN

ELSE

E N

OTE

4

CIR

CU

IT B

REA

KER

SEE

NO

TE 3

REM

OVA

BLE

STU

B-U

P C

OVE

RSE

E N

OTE

4

CU

STO

MER

AC

CES

S AS

SEM

BLY,

CO

NTR

OL

PAN

EL A

CC

ESS,

BA

TTER

Y C

HAR

GER

LO

CAT

ED W

ITH

IN,

SEE

NO

TE 4

REA

R V

IEW

LIFT

ING

PR

OVI

SIO

N (4

PLA

CES

) SE

E N

OTE

S 5,

8 A

ND

CEN

TER

O

F G

RAV

ITY

DIM

ENSI

ON

SR

IGH

T SI

DE

VIEW

VISE

AC

TIO

N L

ATC

H, O

NE

PER

D

OO

R, O

NE

LIFT

-OFF

DO

OR

PE

R S

IDE

OF

GEN

ERAT

OR

OPE

N P

UN

CH

ED L

OU

VER

S TY

PIC

AL O

N B

OTH

SID

ES O

F FU

EL T

ANK

VEN

TILA

TIO

N

DU

CT

TO P

RO

VID

E AD

EQU

ATE

CR

OSS

-FLO

W O

F AI

R

VEN

TILA

TIO

N

EXH

AUST

MU

FFLE

R

ENC

LOSE

D W

ITH

IN

GEN

ERAT

OR

EN

CLO

SUR

E

LEFT

SID

E VI

EW

BATT

ERY

12 V

OLT

N

EGAT

IVE

GR

OU

ND

REM

OVE

CO

VER

FO

R

ACC

ESS

TO R

ADIA

TOR

FI

LL C

AP TOP

VIEW

Page 9: Protector™ Series Diesel Generator Set · Isochronous Electronic Governor Sound Attenuated Aluminum Enclosure Smart Battery Charger UV / Ozone Resistant Hoses ±1% Voltage Regulation

9 of 12

30 kW installation layout

®

Prot

ecto

r™

D2.2L G22 Single Wall (2 of 2)

43

21

43

1

AB

AB

888

[35.

0]

851

[33.

5]M

OU

NTI

NG

CE

NTE

RS

TYP

19[.7

]TY

P

397

[15.

6]

112

[4.4

]TY

P71

2[2

8.0]

TYP

1242

[48.

9]TY

P18

42[7

2.5]

TYP

1954

[76.

9]

250

[9.9

]FU

EL

TAN

KH

EIG

HT

844

[33.

2]TY

P926

[36.

5]TY

P

1045

[41.

2]

1196

[47.

1]

1430

[56.

3]

1690

[66.

5]

1555

[61.

2]

181

[7.1

]TY

P

621

[24.

5]TY

P

757

[29.

8]TY

P

267

[10.

5]TY

P

125

[4.9

]S

TUB

-UP

AR

EA

125

[4.9

]S

TUB

-UP

AR

EA

253

[10.

0]

51 [2.0

]

38 [1.5

]

786

[30.

9]

850

[33.

5]

62[2

.5]

DR

AWIN

G C

REA

TED

FR

OM

PR

O/E

NG

INEE

R3D

FIL

E. E

CO

MO

DIF

ICAT

ION

TO

BE

APPL

IED

TO

SO

LID

MO

DEL

ON

LY.

TIT

LE

INS

TALL

PR

OTE

CTO

R D

2.2L

G22

SIN

GLE

WA

LL T

AN

K

ISSU

E D

ATE:

07/2

017

SIZ

EC

AG

E N

OD

WG

NO

1000

0018

294

RE

V

BN

/A

ASC

ALE

0.07

5 W

T-K

GS

EE

AB

OV

ES

HE

ET

2 of

2

GE

NE

RA

C P

OW

ER

SY

STE

MS

OW

NS

TH

E C

OP

YR

IGH

T O

F TH

IS D

RA

WIN

GW

HIC

H IS

SU

PP

LIE

D IN

CO

NFI

DE

NC

E A

ND

MU

ST

NO

T B

E U

SE

D F

OR

AN

Y P

UR

PO

SE

OTH

ER

TH

AN

FO

R W

HIC

H IT

IS S

UP

PLI

ED

WIT

HO

UT

THE

EX

PR

ES

S W

RIT

TEN

CO

NS

EN

T O

F G

EN

ER

AC

PO

WE

R S

YS

TEM

S.

c G

EN

ER

AC

PO

WE

R S

YS

TEM

S 2

013

ELEC

TRO

NIC

ALLY

APP

RO

VED

INSI

DE

WIN

DC

HIL

L

SH

2/2

REV

AW

INDC

HILL

VER

SION

A.4

FUE

L TA

NK

TOTA

L C

AP

AC

ITY

253.

6 [6

7]U

SA

BLE

CA

PA

CIT

Y23

0.9

[61]

CA

PA

CIT

Y: L

ITE

R [G

ALL

ON

S]

DIM

EN

SIO

NS

: MM

[IN

CH

]

*NO

TE: S

TUB

-UP

AR

EA

FO

R H

IGH

A

ND

LO

W V

OLT

AG

E C

ON

NE

CTI

ON

S,

CIR

CU

IT B

RE

AK

ER

, NE

UTR

AL

AN

D

CU

STO

ME

R C

ON

NE

CTI

ON

OP

EN

ING

.

RE

AR

VIE

W

16.7

[0.6

6]

MO

UN

TIN

G H

OLE

S

(8 P

LAC

ES

) SE

E

NO

TE 9

RE

MO

VA

BLE

S

TUB

-UP

CO

VE

RS

EE

NO

TE 4

LEFT

SID

E V

IEW

RE

MO

VA

BLE

CO

VE

R

TOP

VIE

W

HIG

H A

ND

LO

W

VO

LTA

GE

STU

B-U

P

AR

EA

EM

ER

GE

NC

Y V

EN

T(2

" NP

T FE

MA

LE)

NO

RM

AL

VE

NT

(2" N

PT

FEM

ALE

)

FUE

L LE

VE

LG

AU

GE

/SE

ND

ER

FUE

L FI

LL(2

" NP

T FE

MA

LE)

FUE

L S

UP

PLY

FUE

L R

ETU

RN

Page 10: Protector™ Series Diesel Generator Set · Isochronous Electronic Governor Sound Attenuated Aluminum Enclosure Smart Battery Charger UV / Ozone Resistant Hoses ±1% Voltage Regulation

10 of 12

48 • 50 kW installation layout

®

Prot

ecto

r™

D3.4L Single Wall (1 of 2)

302

[11.

9]

1954

[76.

9]O

VER

ALL

LEN

GTH

182

[7.2

]

1408

[55.

4]O

VER

ALL

HE

IGH

T

888

[35.

0]O

VER

ALL

WID

TH

758

[29.

8]D

OO

R T

YP

173

[6.8

]

146

[5.8

]

1322

[52.

0]

892

[35.

1]C

ENTE

R O

F G

RA

VITY

SEE

NO

TE 5

SER

VIC

E IT

EM

3.4L

OIL

FIL

L C

AP

RIG

HT

SID

EO

IL D

IP S

TIC

KR

IGH

T SI

DE

OIL

FIL

TER

RIG

HT

SID

EO

IL D

RA

IN H

OS

ER

IGH

T SI

DE

RAD

IATO

R D

RAI

N H

OSE

LEFT

SID

EA

IR C

LEAN

ER E

LEM

EN

TR

IGH

T SI

DE

MU

FFLE

RFR

ON

TFA

N B

ELT

EIT

HER

SID

EB

ATT

ERY

LEFT

SID

E

WEI

GH

T D

ATA

WIT

H E

MP

TY B

AS

ETA

NK

(SEE

NO

TE 5

)

GEN

ER

ATO

R A

S S

HO

WN

(STE

EL E

NC

L)88

6 [1

953]

WIT

H W

OO

DEN

SH

IPPI

NG

SK

ID92

5 [2

039]

INS

TALL

CP

L P

RO

T D

3.4L

SW

0K69

68A

B

GE

NE

RA

C P

OW

ER

SY

STE

MS

OW

NS

TH

E C

OPY

RIG

HT

OF

THIS

DR

AW

ING

WH

ICH

IS S

UPP

LIE

D IN

CO

NFI

DE

NC

E A

ND

MU

ST

NO

T B

E U

SE

D F

OR

AN

Y P

UR

PO

SE

OTH

ER

TH

AN

FO

R W

HIC

H IT

IS S

UP

PLI

ED

WIT

HO

UT

THE

EX

PR

ES

S W

RIT

TEN

CO

NS

EN

T O

F G

EN

ER

AC

PO

WE

R S

YS

TEM

S.

c G

EN

ER

AC

PO

WE

R S

YS

TEM

S 2

013

NO

TES

: 1.

MIN

IMU

M R

ECO

MM

EN

DED

CO

NC

RET

E P

AD S

IZE:

119

4 (4

7") W

IDE

X 2

261

(89

") L

ON

G. R

EFE

RE

NC

E IN

STA

LLAT

ION

GU

IDE

SU

PPLI

ED W

ITH

UN

IT F

OR

CO

NC

RET

E P

AD G

UID

ELI

NES

2. A

LLO

W S

UFF

ICIE

NT

RO

OM

ON

ALL

SID

ES O

F TH

E G

ENER

ATO

R F

OR

MA

INTE

NA

NC

E A

ND

SER

VIC

ING

. TH

IS U

NIT

MU

ST B

E IN

STA

LLE

D IN

AC

CO

RD

AN

CE

WIT

H C

UR

RE

NT

APP

LIC

ABL

E N

FPA

37 A

ND

NFP

A 70

STA

ND

AR

DS

AS

WE

LL A

S A

NY

OTH

ER F

ED

ERA

L, S

TATE

AN

D L

OC

AL C

OD

ES.

3. C

ON

TRO

L PA

NE

L / C

IRC

UIT

BR

EA

KER

INFO

RM

ATIO

N:

- S

EE S

PEC

IFIC

ATI

ON

SH

EET

OR

OW

NE

RS

MAN

UEL

- A

CC

ES

SIB

LE T

HR

OU

GH

CU

STO

ME

R A

CC

ESS

AS

SEM

BLY

DO

OR

ON

RE

AR

OF

GE

NER

ATO

R4.

REM

OV

E TH

E R

EA

R T

ANK

AN

D R

EA

R E

NC

LOSU

RE

CO

VER

PA

NE

L TO

AC

CE

SS T

HE

STU

B-U

P A

REA

S A

S FO

LLO

WS

:

-HIG

H V

OLT

AGE

CO

NN

ECTI

ON

INC

LUD

ING

AC

LO

AD L

EAD

CO

ND

UIT

CO

NN

ECTI

ON

NEU

TRA

L C

ON

NEC

TIO

N, B

ATT

ERY

CH

ARG

ER 1

20 V

OLT

AC

(0.5

AM

P M

AX)

CO

NN

ECTI

ON

.

-LO

W V

OLT

AGE

CO

NN

ECTI

ON

S IN

CLU

DE

TR

ANS

FER

SW

ITC

H C

ON

TRO

L W

IRES

5. C

ENTE

R O

F G

RA

VITY

AN

D W

EIG

HT

MA

Y C

HAN

GE

DU

E TO

UN

IT O

PTI

ON

S.6.

EN

GIN

E S

ER

VIC

E C

ON

NE

CTI

ON

S O

IL D

RAI

N: 3

/8" N

PT

EXH

AUS

T O

UTL

ET:

2" O

.D.

7. B

OTT

OM

OF

GE

NER

ATO

R S

ET M

US

T B

E E

NC

LOS

ED T

O P

RE

VEN

T PE

ST IN

TRU

SIO

N A

ND

REC

IRC

ULA

TIO

N O

F D

ISC

HAR

GE

AIR

AN

D/O

R IM

PR

OP

ER C

OO

LIN

G A

IR F

LOW

.8.

EXH

AUS

T SY

STE

M M

AXIM

UM

BA

CK

PR

ESSU

RE:

35

INC

HES

H20

.9.

REF

ERN

CE

OW

NER

S M

AN

UAL

FO

R L

IFTI

NG

WA

RN

ING

S.10

. MO

UN

TIN

G B

OLT

S O

R S

TUD

S TO

CO

NC

RE

TE P

AD

SH

ALL

BE

5/8-

11 G

RAD

E 5

UN

ITS:

WEI

GH

T - K

G [L

BS]

D

IME

NS

ION

- M

M [I

NC

H]

REF

ER

ENC

E O

WN

ER

S M

AN

UA

L FO

R P

ER

IOD

ICR

EPLA

CE

MEN

T P

ART

LIS

TIN

GS.

TOP

VIE

W

RIG

HT

SID

E V

IEW

RE

AR

VIE

WLE

FT S

IDE

VIE

W

RA

DIA

TOR

/EX

HA

US

TD

ISC

HA

RG

E A

IR

EXH

AUST

MU

FFLE

R E

NC

LOS

ED W

ITH

ING

ENE

RA

TOR

EN

CLO

SUR

E

REA

R T

ANK

CO

VER

SE

E N

OTE

4

FRO

NT

TAN

KC

OVE

R

CU

STO

ME

R A

CC

ESS

AS

SEM

BLY

, CO

NTR

OL

PAN

EL

AC

CES

S, B

ATT

ER

Y C

HA

RG

ER

LOC

ATE

D W

ITH

INS

EE

NO

TE 4

CIR

CU

IT B

RE

AKER

SEE

NO

TE 3

REA

R E

NC

LOS

UR

E C

OV

ERP

ANEL

SEE

NO

TE 4

LIFT

ING

PR

OVI

SIO

NS

(4 P

LAC

ES)

SEE

NO

TE 1

0 A

ND

CE

NTE

RO

F G

RAV

ITY

DIM

ENSI

ON

S

VIS

E A

CTI

ON

LAT

CH

,O

NE

PER

DO

OR

, ON

E LI

FT-O

FFD

OO

R P

ER S

IDE

OF

GE

NE

RA

TOR

AIR

INTA

KE

(BO

TH S

IDE

S)

RA

DIA

TOR

/EX

HA

US

TD

ISC

HA

RG

E A

IR(B

OTH

SID

ES

)

REM

OV

E C

OVE

RFO

R A

CC

ESS

TOR

ADIA

TOR

FIL

L C

AP

BA

TTER

Y 1

2 VO

LTN

EGA

TIVE

GR

OU

ND

Page 11: Protector™ Series Diesel Generator Set · Isochronous Electronic Governor Sound Attenuated Aluminum Enclosure Smart Battery Charger UV / Ozone Resistant Hoses ±1% Voltage Regulation

11 of 12

48 • 50 kW installation layout

®

Prot

ecto

r™

D3.4L Single Wall (2 of 2)

1688

[66.

4]25

3[1

0.0]

125

[4.9

]*S

TUB-

UPAR

EA

786

[30.

9]

76[3

.0]

112

[4.4

]*S

TUB-

UPAR

EA

1044

[41.

1]11

94[4

7.0]

828

[32.

6] T

YP

923

[36.

4] T

YP

757

[29.

8]TY

P 621

[24.

5]TY

P 267

[10.

5]TY

P18

1[7

.1]

TYP

1431

[56.

3]

1554

[61.

2]

51[2

.0]

38[1

.5]

112

[4.4

] TYP

712

[28.

0] T

YP

1242

[48.

9] T

YP

1842

[72.

5] T

YP

1954

[76.

9]

353

[13.

9]

888

[35.

0]

851

[33.

5] T

YP

INST

ALL

CPL

PRO

T D

3.4L

SW

0K69

68A

B

GEN

ERAC

PO

WER

SYS

TEM

S O

WNS

THE

CO

PYR

IGHT

OF

THIS

DR

AWIN

GW

HICH

IS S

UPP

LIED

IN C

ONF

IDEN

CE

AND

MU

ST N

OT

BE U

SED

FO

RAN

Y PU

RPO

SE O

THER

THA

N F

OR

WH

ICH

IT IS

SUP

PLIE

D W

ITHO

UTTH

E EX

PRES

S W

RITT

EN C

ON

SENT

OF

GEN

ERAC

PO

WER

SYS

TEM

S.c

GEN

ERAC

PO

WER

SYS

TEM

S 20

13

FUEL

TAN

KTO

TAL

CAP

ACIT

Y25

3.6

[67]

USAB

LE C

APAC

ITY

230.

9 [6

1]

CAP

ACIT

Y: L

ITER

[GAL

LON

S]D

IMEN

SIO

NS: M

M [I

NC

H]

*NO

TE: S

TUB-

UP

AREA

FO

R H

IGH

AND

LO

W V

OLT

AGE

CO

NNEC

TIO

NS,

CIR

CU

IT B

REA

KER

, NEU

TRAL

AN

DC

USTO

MER

CO

NNE

CTI

ON

OPE

NIN

G.

REM

OVA

BLE

STU

B-UP

CO

VER

REM

OVA

BLE

CO

VER

HIG

H AN

D LO

WVO

LTAG

E ST

UB-U

P

INNE

R T

ANK

NOR

MAL

VEN

T(2

" NPT

FEM

ALE)

INNE

R T

ANK

EMER

GEN

CY V

ENT

(2" N

PT F

EMAL

E)

FUEL

LEV

ELG

AUG

E/SE

NDER

FUEL

FIL

L(2

" NPT

FEM

ALE)

FUEL

RET

URN

FUEL

SUP

PLY

16.7

[.66

] MO

UNTI

NG H

OLE

S(8

PLA

CES

)

Page 12: Protector™ Series Diesel Generator Set · Isochronous Electronic Governor Sound Attenuated Aluminum Enclosure Smart Battery Charger UV / Ozone Resistant Hoses ±1% Voltage Regulation

12 of 12

Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com

©2018 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. 10000023918 rev C (08/13/18)

®

®

15 • 20 • 30 • 48 • 50 kW available accessories

Prot

ecto

r™

MODEL # PRODUCT DESCRIPTION

G006505-0 - 15 & 20 kWG006506-0 - 30, 48, & 50 kW

Tank RisersTank risers are required in some municipalities to help avoid potential base tank corrosion caused by mounting on rough surfaces.

G006512-0 Lockable Fuel CapThe cast iron, lockable fuel cap provides the ability to lock the fuel system to prevent unwanted fuel tampering or fuel siphoning.

G007640-0 - 15 & 20 kWG007641-0 - 30 kWG006570-0 - 48 & 50 kW

Maintenance KitsThe Protector Maintenance Kits offer all the hardware necessary to perform complete maintenance on Ottomotores Protector generators.

G007650-0 - 15 & 20 kWG007651-0 - 30 kWG006558-0 - 48 & 50 kW

Cold Weather KitsRecommended for generators installed in regions where the temperature regularly falls below 32 °F (0 °C). The Cold Weather Kits consist of a block heater with all necessary mounting hardware and a battery warmer with a thermostat built into the battery wrap.

G005703-0 Paint KitIf the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch up a generator enclosure.

G006873-0Smart Management Module (50 Amps)

Manage large loads by utilizing up to 8 individual Smart Management Modules. These devices are installed directly in line with existing appliance wiring for easy installation.