LubricationManagementSystems
MaterialDispensingManagementSystems
Hose & CableManagementSystems
Diesel & FluidManagementSystems
FireExtinguisher& SuppressionSystems
Onboard Weighing &CCTV Systems
Flow MeasurementSystems
General Lubrication& Exhaust Extraction
JSG Industrial Systemsquality industry solutions
Outset LANX HD
• Protect your vehicles and investment against wear and tear from overloading
• Optimise your material management with easy to use weight management and automatic data logging system
Page 2 JSG Industrial Systems
Technical data Lanx HD
Display Back-lit LCD 2x16 characters
Screen Tonne or kilogram
Multilingual
Working Temperature 0° - 50° C
Power Supply 18 - 30 Vdc
Protection level IP40
Max current 0.5A a 24 Vdc
Dimensions 152x108x42mm without flange
Colour Carbon black
LANX HD only for heavy duty work
A fast return on your investmentThe system pays for itself immediately because knowing the weight of the load when you travel means optimizing transport times and economic yield in complete safety.
Easy to read displayThe control unit of the LANX HD system is directly installed in the driver’s cab and displays the weight loaded on-board in real time. It allows a reading axle by axle, net and gross or partial.
Concise reporting dataTrips are automatically memorized without the requirement for operator intervention. The internal database allows display of reports for each round trip, including material, operator or destination, date, time and weight data, as well as daily, weekly and monthly reports with individual and overall totals for all loads transported. Weighing data and individual reports can be transmitted via GPRS or printed. The USB reader connects with the LANX HD system allows to save the weights made through a USB Flash Drive device.
Advantages• Convenient on-board weighing during loading• Automatic memorization of weight, date and time• Management of Materials and Operators/Destinations• Load Database• Productivity checks on a daily, weekly and monthly basis• Programmable alarm limits for loading/overloading, with
external optical devices• Protection against early wear of the vehicle• Possibility of transmission data via GPRS
1 LANX HD displays all data during the loading process with an easy to read display and without having the need to push any keys.
2 LANX HD uses; ES160 or ES400, digital pressure sensors dependant on vehicle size. The sensors are positioned on each of the vehicle’s suspension struts. All carry an IP 65 rating.
3 External optional devices
1 3
2 2
Part No. Description
36-LANXGLO-S4HLT Head unit, sensors and installation kit
36-LANXGLO-S4HLT-A Head Unit, sensors and installation kit (including data transmission cable)
Page 3JSG Industrial Systems
Technical Data Sensor 160 Bar Sensor 400 Bar
Range 0 - 160 Bar 0 - 400 Bar
Safe Overload 150% 150%
Compensated Temperature -20° - +50° C -20° - +50° C
Protection Level IP65 IP65
Dimensions 145x72x35 mm 145x72x35 mm
Weight 400 grams 400 grams
Hydropneumatic Suspensions
The digital sensors, which are installed on the suspensions, record the pressure variation due to the weight loaded on the vehicle, by sending data to the LANX unit located in the cab. Sensors have a high IP65 protection level stopping high levels of dust and are pressure washer safe.
Installation References
Accuracy: 0÷3%
Sensors Position 160 bar / 400 bar
Tough trucks need tough systems
Lanx HD installed on the dashPressure transducers connected to each hydro pneumatic strut Hydraulic connection to strut
Part No. Description
36-LNXBLES160 ES160 Sensor (single unit)
36-LNXBLES400 ES400 Sensor (single unit)
Exterior indicators
U n i t 1 , 2 1 A m o u r S t R eve s by 2 2 1 2 Au s t ra l i aT: + 6 1 2 9 9 4 1 8 7 2 0 F : + 6 1 2 9 9 1 4 8 7 9 8
E : j s g i n d u s t r i a l @ j s g . c o m . a uW : w w w. j s g i n d u s t r i a l . c o m
Technical data specifications & photographs contained in this brochure were correct at time of printing. Pictures shown are for illustration purposes only. Technical information, specifications & products shown maybe subject to change without prior notice. (Errors & omissions excepted). WARNING: For sale & proper use consult instructions, the supplier or JSG. Contact your nearest JSG Industrial Systems P/L distributor for latest information. OL1112
LubricationManagementSystems
MaterialDispensingManagementSystems
Hose & CableManagementSystems
Diesel & FluidManagementSystems
Fire Extinguisher & Suppression Systems
Onboard Weighing & CCTV Systems
Flow Measurement Systems
General Lubrication& Exhaust Extraction
Your authorised JSG distributor:
CessnockLevel 1/426 Macdonalds Rd Pokolbin NSW 2325
Mobile: 0447 277 755 Email: [email protected]
Brisbane Unit 1/20 Lancashire St Acacia Ridge QLD 4110
Ph: (07) 3273 3433 Fax: (07) 3273 3369 Email: [email protected]
Mackay 2/40 Evans Ave PO BOX 3374
North Mackay QLD 4740 Technical Support Mobile: 0428 277 671 Fax: (07) 4953 3959
Email: [email protected]
Cannonvale29 Jones Rd Cannonvale QLD 4802
Mobile: 0448 022 886 Fax: (07) 4946 5466 Email: [email protected]
TownsvilleLevel 1, 1/5 Woolcock St Hyde Park Townsville QLD 4810
Mobile: 0419 021 892 Fax: (07) 4724 5951 Email: [email protected]
Melbourne 3/62-68 Garden Drive Tullamarine VIC 3043
Ph: (03) 8809 1300 Fax: (03) 9310 4886 Email: [email protected]
Perth2 Holder Way Malaga WA 6090
Ph: (08) 6240 5800 Fax: (08) 9249 9027Email: [email protected]
AdelaideSuite 3, 8 Greenhill Road Wayville SA 5034 Ph: (08) 8372 9503 Mobile: 0448 730 886
Email: [email protected]
SydneyUnit 1, 21 Amour Street Revesby NSW 2212
PO Box 333 Milperra NSW 2214 Ph: (02) 9914 8720 Fax: (02) 9914 8798
Email: [email protected]
IndonesiaPT JSG International
Jl. Ciputat Raya, No. 1C RT.003/RW. 010 Kebayoran Lama Selatan, Kebayoran Lama, Jakarta Selatan 12240
Ph: (62-21) 7239 511 Fax: (62-21) 7289 5623 Email: [email protected]
Optionals
< Printer
< Ticket< USB Reader
Transmission Data Cable RS232< Part No. Description
36-STPM-24 Thermal printer
36-LNXCOM8000 USB reader
36-EXT-USB Transmission data cable RS232
TEREX NHL NUMBERS
36-20036464 Suits TR50, 60, 100
36-20036465 Suits TR150, NTE150, NTE240Machines not shown here can be requested.