DESCRIPTION
PROSTHETIC PROCEDURE MANUAL IR SYSTEM. CEMENTED RESTORATION Implant Level Impression. Cemented Abutment. Set Screw. Impression Coping Pick -up. Implant Analog. Com Octa Plus Abutment. Angled Abutment. CEMENTED RESTORATION Abutment Level Impression. Cuff Solid Abutment. Single . - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/1.jpg)
PROSTHETIC PROCEDURE MANUALIR SYSTEM
![Page 2: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/2.jpg)
CEMENTED RESTORATIONImplant Level Impression
Set ScrewImpression
CopingPick-up
Implant Analog
CementedAbutment
AngledAbutment
Com Octa Plus Abutment
![Page 3: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/3.jpg)
CEMENTED RESTORATIONAbutment Level Impression
Solid Abutment Solid
Abutment Analog
Single
Bridge
Impression CopingTransfer
Cuff Solid Abutment
Wide Solid Abutment
![Page 4: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/4.jpg)
IMPRESSION COPINGSImplant Level – Pick-up
• Implant level impression, pick-up impression coping (open tray technique)• Impression coping is packaged with corresponding guide pin• Use 1.2mm Hex driver to assemble/ disassemble
Engaging
Guide Pin
1.2mm Hex Driver
![Page 5: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/5.jpg)
IMPRESSION COPINGSAbutment Level – Transfer
• Abutment level impression, transfer impression coping (closed tray technique)
![Page 6: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/6.jpg)
IMPLANT ANALOG
![Page 7: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/7.jpg)
SOLID ABUTMENT ANALOG
![Page 8: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/8.jpg)
CEMENTED ABUTMENT
Fastening torque 30 Ncm
HEIGHT
Engaging
1.2mm Hex Driver
![Page 9: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/9.jpg)
ANGLED ABUTMENT
Fastening torque 30 Ncm
HEIGHT
Engaging
1.2mm Hex Driver
![Page 10: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/10.jpg)
COM OCTA PLUS ABUTMENT
Fastening torque 30 Ncm
HEIGHT
CUFF
DIAMETER
Engaging
1.2mm Hex Driver
![Page 11: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/11.jpg)
SOLID ABUTMENT
Fastening torque 30 Ncm
HEIGHT
Non Engaging
1.2mm Hex Driver
Protective Cap
![Page 12: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/12.jpg)
WIDE SOLID ABUTMENT
Fastening torque 30 Ncm
HEIGHT
Non Engaging
1.2mm Hex Driver
Protective Cap
![Page 13: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/13.jpg)
CUFF SOLID ABUTMENT
Fastening torque 30 Ncm
HEIGHT
Non Engaging
1.2mm Hex Driver
Protective CapCUFF
![Page 14: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/14.jpg)
SET SCREW
• Cemented Abutment screw is 10mm long• Angled Abutments screw is 8mm long• Set screws are packaged along with corresponding abutment
LENGTH
DIAMETER
![Page 15: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/15.jpg)
CLINICAL PROCESSFixing Impression Copings (1/3)
• View of patient’s mouth
![Page 16: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/16.jpg)
CLINICAL PROCESSFixing Impression Copings (2/3)
• Remove healing abutment / cover screw with 1.2mm Hex Driver
• Insert impression coping inside corresponding implant connection
![Page 17: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/17.jpg)
CLINICAL PROCESSFixing Impression Copings (3/3)
• Fasten impression coping with corresponding guide pin• Tighten guide pin with 1.2mm hex driver
![Page 18: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/18.jpg)
CLINICAL PROCESSTaking The Impression (1/6)
• Apply the light impression material on corresponding site of oral cavity
![Page 19: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/19.jpg)
CLINICAL PROCESSTaking The Impression (2/6)
• Pour the heavy impression material inside the impression tray
![Page 20: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/20.jpg)
CLINICAL PROCESSTaking The Impression (3/6)
• Position tray for impression taking• Apply pressure until top part of guide pin appears• wait for impression material to set• Transfer impression copings will require prefabricated tray• Pick-up impression copings will require previously customized tray
![Page 21: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/21.jpg)
CLINICAL PROCESSTaking The Impression (4/6)
• Remove guide pin
![Page 22: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/22.jpg)
CLINICAL PROCESSTaking The Impression (5/6)
• Check tray for impression errors / success
![Page 23: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/23.jpg)
CLINICAL PROCESSTaking The Impression (6/6)
• Replace healing abutment / cover screw in corresponding site
![Page 24: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/24.jpg)
LABORATORY PROCESS1. Fixing Analogs & Making Artificial Gum (1/4)
• Fix analogs on corresponding impression coping
![Page 25: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/25.jpg)
LABORATORY PROCESS1 - Fixing Analogs & Making Artificial Gum (2/4)
• Apply (Spray) separating product on impression areas
![Page 26: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/26.jpg)
LABORATORY PROCESS1. Fixing Analogs & Making Artificial Gum (3/4)
• Apply artificial gum product on intervention area• Wait for product to dry
![Page 27: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/27.jpg)
LABORATORY PROCESS1. Fixing Analogs & Making Artificial Gum (4/4)
• Trim gum
![Page 28: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/28.jpg)
LABORATORY PROCESS2. Master Modeling (1/3)
• Prepare (mix) the stone
![Page 29: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/29.jpg)
LABORATORY PROCESS2. Master Modeling (2/3)
• Pour the mixed stone inside the impression
![Page 30: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/30.jpg)
LABORATORY PROCESS2. Master Modeling (3/3)
• Master model finishing work
![Page 31: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/31.jpg)
LABORATORY PROCESS3. Abutment Milling (1/5)
• Fix the abutment to the analog
![Page 32: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/32.jpg)
LABORATORY PROCESS3. Abutment Milling (2/5)
• Abutment Milling (Step 1)
![Page 33: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/33.jpg)
LABORATORY PROCESS3. Abutment Milling (3/5)
• Abutment Milling (Step 2)
![Page 34: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/34.jpg)
LABORATORY PROCESS3. Abutment Milling (4/5)
• Abutment Milling (Step 3)
![Page 35: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/35.jpg)
LABORATORY PROCESS3. Abutment Milling (5/5)
• Post Milling
![Page 36: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/36.jpg)
LABORATORY PROCESS4. Pattern Resin & Wax-Up (1/3)
![Page 37: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/37.jpg)
LABORATORY PROCESS4. Pattern Resin & Wax-Up (2/3)
• Wax-up process (Steps 1 & 2)
![Page 38: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/38.jpg)
LABORATORY PROCESS4. Pattern Resin & Wax-Up (3/3)
• Wax-up process (Steps 3 & 4)
![Page 39: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/39.jpg)
LABORATORY PROCESS5. Sprewing (1/2)
• Sprewing (Step 1)
![Page 40: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/40.jpg)
LABORATORY PROCESS5. Sprewing (2/2)
• Sprewing (Step 2)
![Page 41: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/41.jpg)
LABORATORY PROCESS6. Investment (1/2)
• Investment (Step 1)
![Page 42: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/42.jpg)
LABORATORY PROCESS6. Investment (2/2)
• Investment (Step 2)
• Burn out (Step 3)
![Page 43: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/43.jpg)
LABORATORY PROCESS7. Casting
• Cast and extract cast structure
![Page 44: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/44.jpg)
LABORATORY PROCESS8. Adaptation & Metal Trimming
• Check cast structure for adaptation on master model
![Page 45: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/45.jpg)
LABORATORY PROCESS9. Finishing
![Page 46: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/46.jpg)
LABORATORY PROCESS10. Transfer Jig (1/2)
• Make the transfer Jig
![Page 47: PROSTHETIC PROCEDURE MANUAL IR SYSTEM](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816359550346895dd41842/html5/thumbnails/47.jpg)
LABORATORY PROCESS10. Transfer Jig (2/2)
• Place the abutment(s) inside the oral cavity by using the transfer jig