proposed new 1 / sh.ar-111.d 1 / sh.ar-111.d … · sewer line proposed new sewer connection...

1
2 AR-514.C 4 AR-506.A 2 AR-513.C 4 AR-514.C SLOPING LANDSCAPING WATERFALL EDGE PLANTER WITH SEATING PLANTER WITH SEATING WATER FEATURE PLANTER WITH SEATING PLANTER WITH SEATING PLANTER PLANTER PLANTER PLANTER PLANTER PLANTER SEATING SEATING PLANTER PLANTER LASER-CUT METAL SCREEN UP 6.0 7.0 8.0 7.0 BASEMENT ENTRY RAMP POOL LAWN POOL PAVILLION MULTI- PURPOSE PAVILLION MULTI- PURPOSE PAVILLION MULTI- PURPOSE PAVILLION MULTI- PURPOSE PAVILLION MALE FEMALE MULTI- PURPOSE PAVILLION TERRACED PLANTING TERRACED PLANTING TRANSFORMER RL 9.95 RAMP 1:14 PAVING PATTERNS RL 8.72 RL 8.40 COVERED WALKWAY RL 6.95 RL 6.20 RL 7.95 1.8m Min ACOUSTIC WALL LOADING BAY COVERED WALKWAY COVERED WALKWAY POOL PAVILLION RL 5.95 RL 8.80 RL 8.60 RL 8.72 RL 8.40 1:20 UPPER LAWN LOWER LAWN LAWN 1:20 RL 9.95 SEATING SEATING WATERFALL EDGE SHALLOW WATER FEATURE STAGE-2 TURFED AREA OVER BASEMENT BELOW 7.0 1.8m ACOUSTIC FENCE DOWN TO MEZZANINE STORAGE BBQ NEW STORMWATER PIT PROPOSED NEW SEWER LINE PROPOSED NEW SEWER CONNECTION PROPOSED NEW STORMWATER EASEMENT PROPOSED NEW STORMWATER PIT PROPOSED NEW SEWER MANHOLE RETAINING WALL. SURFACE GRADES IN EASEMENT TO ALLOW OVERLAND FLOW SURFACE LEVEL GRADES DOWN SURFACE LEVEL GRADES DOWN SURFACE RL 7.45 SURFACE RL 7.52 7 7 8 8 9 9 1 AR-304.C 3 AR-514.C 2 AR-512.C 3 AR-512.C P.1 P.2 P.3 P.4 P.5 P.6 P.7 P.8 P.9 SSL. 8.400 SSL. 8.400 SSL. 8.400 SSL. 9.950 RL 8.95 SSL. 8.400 1.8m Min ACOUSTIC WALL 1.8m Min ACOUSTIC WALL 1.8m Min ACOUSTIC WALL 1.8m Min ACOUSTIC WALL 1.8m Min ACOUSTIC WALL 1.8m Min ACOUSTIC WALL 3 AR-509.A G.206 Dt.6 G.207 Dt.6 G.28 Dt.3 2 AR-302.C 2 AR-302.C 1 AR-302.C 1 AR-302.C 2 AR-304.C 2 AR-304.C 3 AR-302.C 3 AR-302.C 6 AR-502.A 12 AR-502.A G.206 Dt.6 6 AR-512.C 4 AR-512.C 5 AR-512.C 7 AR-512.C 3 AR-513.C 5 AR-509.A 2X LAP LANES HOSE TAP HOSE TAP HOSE TAP EQUIPMENT ROOM 7 AR-513.C EQ EQ 250mm RAISED PLATFORM 250mm RAISED PLATFORM *FW POOL PUMP ROOM G.208 Dt.20 G.209 Dt.20 SAUNA / 1 SH.AR-111.D / 1 SH.AR-111.D 60 60 60 60 DP DP DP DP DP DP DP WEST EAST SOUTH 2.5m 5m A1 1:100 A3 1:200 1m 10m 5m .5m FIRE MAINS INCLUDING BOOSTER AND /OR PUMPS. REQUIRED FLOW AND TRESSURE TEST 5L/s @ 70kpa (BUILDING PUMP) AND 10 L/s@ 700 lpa (BOOSTED). THE QFES REQUIRE BLOCK PLANS FOR HYDRANT AND BOOSTER CABINETS. ZONE DIAGRAMS FOR FIRE ALARM SYSTEMS TO BE: - ETCHED, ENGRAVED OR PRINTED ON METAL OR PLASTIC THAT IS SUITABLE FOR INSTALLATION IN AN OUTDOOR LOCATION, (PAPER ENCLOSED WITHIN A PLASTIC OR LAMINATED COVER IS NOT ACCEPTABLE). - A MINIMUN OD A3 SIZE - MECHANICALLY SECURED IN THE REQUIRED LOCATION. - CORRECTLY ORIENTATED TO THE BUILDING/SITE AND, - MEET ALL OF THE OTHER REQUIREMENTS OF THE AS. 2419.1-2005 INCLUDING THE FEATURES IDENTIFIED ON THE PLAN. PUMP ROOM WILL REQUIRE ADEQUATE VENTILATION FOR THE ASPIRATION AND COOLING OF THE PUMP DRIVERS. FIRE DETECTION AND ALARM SYSTEMS, (SMOKE ALARMS). ACHEIVEMENT OF A SPECIFIED PERFORMANCE OF DETECTION AND ALARM SYSTEMS SUITABILITY OF NOMINAL TYPES OF DETECTION IN ALL AREAS, AND THE LICATION OF MANUAL CALL POINTS. CERTIFICATION IS REQUIRED FOR EACH SPECIAL FIRE SERVICE, THIS WILL BE REQUIRED PRIOR TO OR AT THE TIME OF INSPECTION. QFES COMLIANT REQUIREMENTS. WET AREA BULKHEADS (RW-CTR 40) 350mm CEAR SPACE. ALL FLOOR PENETRATION TO HAVE FIRE COLLARS. REFER TO BORAL SYSTEMS 'SECTION H' TABLE 17 FOR CORRECT SERVICES SEPERATIONS STD BULKHEADS (RW-CTR 25) CEAR CEILING SPACE AS INICATED ON REFLECTED CEILING PLAN. ALL FLOOR PENETRATION TO HAVE FIRE COLLARS INSTALLED TO MANUFACTURES DETAILS REFER TO BORAL SYSTEMS 'SECTION H' TABLE 17 FOR CORRECT SERVICES SEPERATIONS. STD UNIT ROOF SOFIT. CEILING TO BE PLASTERBOARD ON FURRING CHANNEL SERVICE SHAFTS. (RW-CTR 40) REFER TO BORAL SYSTEMS 'SECTION H' TABLE 17 FOR CORRECT SERVICES SEPERATIONS BV Basement Vent CD Clothes Dryer CP Chrome Polished CT Ceramic Tile DP Down Pipe DPS Downpipe-Spreader DSS Door Smoke Seal DW Dish Washer H? Handrail Type FH Fire Hose FHR Fire Hose Reel FW Floor Waste WC Toilet Pan Si Sink Waste OV Oven PC Powder Coated Finish PSD Patio Sliding Door PG Pool Gate Ref Refridgerator SF Stone Finish SS Stainless Steel WM Washing Machine LT Laundry Tub WS Wheel Stop W? Wall Type TI Tactile Indicators DVS Ducted Vacuum System VB Vanity c1 Column Type TC1 Tapered Column ACN:110893493 6/70 BAY TCE. WYNNUM QLD 4178 P.O. BOX 5129 MANLY QLD 4179 E-MAIL: [email protected] TELEPHONE: (07)3348 3727 MOBILE: 0412 087 196 PROJECT These drawings are the copyright of THINK TANK Architects and are not to be reproduced in any way without the consent of THINK TANK Architects CLIENT ADDRESS ARCHITECT DATE DRAWING NAME SCALE DWG NO. REVISION DRAWN BY CHECKED BY MICHAEL JULLYAN AT A1 C:\Users\garydeane.TTARCHITECTS\Documents\REVIT LOCAL FILE\TOONDAH OUTLOOK BA1_MichaelJullyan8412.rvt As indicated WHARF,MIDDLE & SHORE ST EAST TOONDAH OUTLOOK ANDERSON FAMILY TRUST GD GROUND SOUTH AR-113.D 25-08-17 36-14 #4 BA1 ISSUE MJ @A1 1 : 100 2C GROUND SOUTH 1 N ORT H REVISION HISTORY REV DESCRIPTION DATE 3 Rev-C BA 1 PRELIM 11-08-17 1 Rev-A BA PRELIM 12-05-17 2 Rev-B BA PRELIM UPDATES 25-07-17 4 BA1 ISSUE 25-08-17

Upload: leminh

Post on 03-Sep-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PROPOSED NEW 1 / SH.AR-111.D 1 / SH.AR-111.D … · sewer line proposed new sewer connection proposed new ... drawing name scale dwg no. revision ... mj 1 : 100 @a1 2c ground south

2

AR-514.C

4

AR-506.A

2

AR-513.C

4

AR-514.C

SLO

PIN

G L

AN

DS

CA

PIN

G

WATERFALL EDGE

PLANTERWITH

SEATING

PLANTERWITH

SEATING

WATERFEATURE

PLANTERWITH

SEATING

PLANTERWITH

SEATING

PLANTER

PLANTER

PLA

NTER

PLA

NTER

PLA

NTER

PLA

NTER

SEATING

SEATING

PLANTER

PLA

NTER

LASER-CUT METAL SCREEN

UP

6.0

7.0

8.0 7.0

BA

SE

ME

NT

EN

TR

Y R

AM

P

POOL

LAWN

POOLPAVILLION

MULTI-PURPOSEPAVILLION

MULTI-PURPOSEPAVILLION

MULTI-PURPOSEPAVILLION

MULTI-PURPOSEPAVILLION

MALE

FEMALE

MULTI-PURPOSEPAVILLION

TERRACED PLANTING

TERRACED PLANTING

TRANSFORMER

RL 9.95

RAMP 1:14

PAVINGPATTERNS

RL 8.72

RL 8.40

COVERED W

ALK

WAY

RL 6.95

RL 6.20

RL 7.95

1.8m MinACOUSTIC WALL

LOADING BAY

COVEREDWALKWAY

COVERED WALKWAY

POOLPAVILLION

RL 5.95

RL 8.80

RL 8.60

RL 8.72 RL 8.40

1:2

0

UPPERLAWN

LOWERLAWN

LAWN

1:20

RL 9.95

SEATING

SEATING

WATERFALL EDGE

SHALLOWWATERFEATURE

STAGE-2TURFED AREA OVERBASEMENT BELOW

7.0

1.8m ACOUSTIC FENCE

DOWN TOMEZZANINESTORAGE

BBQ

NEW STORMWATER PIT

PROPOSED NEWSEWER LINE

PROPOSED NEWSEWER CONNECTION

PROPOSED NEWSTORMWATEREASEMENT

PROPOSED NEWSTORMWATER PIT

PROPOSED NEWSEWER MANHOLE

RETAINING WALL. SURFACEGRADES IN EASEMENT TOALLOW OVERLAND FLOW

SURFACE LEVEL GRADES DOWN

SURFACE LEVEL GRADES DOWN

SURFACE RL 7.45 SURFACE RL 7.52

7 7

8 8

9 9

1

AR-304.C

3

AR-514.C

2

AR-512.C

3

AR-512.C

P.1

P.2

P.3

P.4

P.5

P.6

P.7

P.8

P.9

SSL. 8.400

SSL. 8.400

SSL. 8.400

SSL. 9.950

RL 8.95

SSL. 8.400

1.8m MinACOUSTIC WALL

1.8m MinACOUSTIC WALL

1.8m MinACOUSTIC WALL

1.8m MinACOUSTIC WALL

1.8m MinACOUSTIC WALL

1.8m MinACOUSTIC WALL

3

AR-509.A

G.206

Dt.6

G.207

Dt.6

G.28

Dt.3

2

AR-302.C

2

AR-302.C

1

AR-302.C

1

AR-302.C

2

AR-304.C

2

AR-304.C

3

AR-302.C

3

AR-302.C

6

AR-502.A

12

AR-502.A

G.206

Dt.6

6

AR-512.C

4

AR-512.C

5

AR-512.C

7

AR-512.C

3

AR-513.C

5

AR-509.A

2X LAP LANES

HOSETAP

HOSETAP

HOSETAP

EQUIPMENTROOM

7

AR-513.C

EQ

EQ

250mmRAISED

PLATFORM

250mmRAISED

PLATFORM

*FW

POOL PUMPROOM

G.208

Dt.20

G.209

Dt.20

SAUNA/1 SH.AR-111.D/1 SH.AR-111.D

606060 60

DP

DP

DP

DP

DP

DP

DP

WEST EAST

SOUTH

2.5m

5mA1

1:100A3

1:2001m

10m

5m

.5m

FIRE MAINS INCLUDING BOOSTER AND /OR PUMPS.REQUIRED FLOW AND TRESSURE TEST 5L/s @ 70kpa (BUILDING PUMP) AND 10 L/s@700 lpa (BOOSTED).THE QFES REQUIRE BLOCK PLANS FOR HYDRANT AND BOOSTER CABINETS.ZONE DIAGRAMS FOR FIRE ALARM SYSTEMS TO BE:- ETCHED, ENGRAVED OR PRINTED ON METAL OR PLASTIC THAT IS SUITABLE FORINSTALLATION IN AN OUTDOOR LOCATION, (PAPER ENCLOSED WITHIN A PLASTICOR LAMINATED COVER IS NOT ACCEPTABLE).- A MINIMUN OD A3 SIZE- MECHANICALLY SECURED IN THE REQUIRED LOCATION.- CORRECTLY ORIENTATED TO THE BUILDING/SITE AND,- MEET ALL OF THE OTHER REQUIREMENTS OF THE AS. 2419.1-2005 INCLUDING THEFEATURES IDENTIFIED ON THE PLAN.PUMP ROOM WILL REQUIRE ADEQUATE VENTILATION FOR THE ASPIRATION ANDCOOLING OF THE PUMP DRIVERS.

FIRE DETECTION AND ALARM SYSTEMS, (SMOKE ALARMS).

ACHEIVEMENT OF A SPECIFIED PERFORMANCE OF DETECTION AND ALARMSYSTEMSSUITABILITY OF NOMINAL TYPES OF DETECTION IN ALL AREAS, AND THE LICATIONOF MANUAL CALL POINTS.

CERTIFICATION IS REQUIRED FOR EACH SPECIAL FIRE SERVICE, THIS WILL BEREQUIRED PRIOR TO OR AT THE TIME OF INSPECTION.

QFES COMLIANT REQUIREMENTS.

WET AREA BULKHEADS (RW-CTR 40)350mm CEAR SPACE.ALL FLOOR PENETRATION TO HAVE FIRE COLLARS.REFER TO BORAL SYSTEMS 'SECTION H' TABLE 17FOR CORRECT SERVICES SEPERATIONS

STD BULKHEADS (RW-CTR 25)

CEAR CEILING SPACE AS INICATED ON REFLECTEDCEILING PLAN.ALL FLOOR PENETRATION TO HAVE FIRE COLLARSINSTALLED TO MANUFACTURES DETAILSREFER TO BORAL SYSTEMS 'SECTION H' TABLE 17FOR CORRECT SERVICES SEPERATIONS.

STD UNIT ROOF SOFIT.CEILING TO BE PLASTERBOARD ON FURRINGCHANNEL

SERVICE SHAFTS. (RW-CTR 40)REFER TO BORAL SYSTEMS 'SECTION H' TABLE 17FOR CORRECT SERVICES SEPERATIONS

BV Basement VentCD Clothes DryerCP Chrome PolishedCT Ceramic TileDP Down PipeDPS Downpipe-SpreaderDSS Door Smoke SealDW Dish WasherH? Handrail TypeFH Fire HoseFHR Fire Hose ReelFW Floor WasteWC Toilet PanSi Sink WasteOV OvenPC Powder Coated FinishPSD Patio Sliding DoorPG Pool GateRef RefridgeratorSF Stone FinishSS Stainless SteelWM Washing MachineLT Laundry TubWS Wheel StopW? Wall TypeTI Tactile IndicatorsDVS Ducted Vacuum SystemVB Vanityc1 Column TypeTC1 Tapered Column

ACN:110893493 6/70 BAY TCE. WYNNUM QLD 4178

P.O. BOX 5129 MANLY QLD 4179 E-MAIL: [email protected] TELEPHONE: (07)3348 3727

MOBILE: 0412 087 196

PROJECT

These drawings are the copyright of THINK TANKArchitects and are not to be reproduced in any waywithout the consent of THINK TANK Architects

CLIENT

ADDRESS

ARCHITECT

DATE

DRAWING NAME

SCALE

DWG NO. REVISION

DRAWN BY CHECKED BY

MICHAEL JULLYAN

AT A1

C:\Users\garydeane.TTARCHITECTS\Documents\REVITLOCAL FILE\TOONDAH OUTLOOKBA1_MichaelJullyan8412.rvt

As indicated

WHARF,MIDDLE & SHORE ST EAST

TOONDAH OUTLOOK

ANDERSON FAMILY TRUST

GD

GROUND SOUTH

AR-113.D

25-08-17

36-14

#4 BA1 ISSUE

MJ

@A1 1 : 100

2C GROUND SOUTH1

NORTH

REVISION HISTORY

REV DESCRIPTION DATE3 Rev-C BA 1 PRELIM 11-08-17

1 Rev-A BA PRELIM 12-05-17

2 Rev-B BA PRELIM UPDATES 25-07-17

4 BA1 ISSUE 25-08-17