promise with intel ms
TRANSCRIPT
![Page 1: Promise With Intel MS](https://reader031.vdocuments.site/reader031/viewer/2022020105/54084cacdab5cac8598b4887/html5/thumbnails/1.jpg)
Page 1 of 7
Intel Modular Server and VTrak E-Class
Supported Configurations
VERSION: 1.1
DATE: October 30, 2008
![Page 2: Promise With Intel MS](https://reader031.vdocuments.site/reader031/viewer/2022020105/54084cacdab5cac8598b4887/html5/thumbnails/2.jpg)
Modular Server / VTrak Configurations
©2008 Promise Technology Inc. All rights reserved. Page 2 of 7
This document is intended as a reference guide for Promise Technology and Intel Modular Server partners only. The document is subject to change without notice.
Copyright
©2008 Promise Technology, Inc. All Rights Reserved.
No part of this document may be reproduced or transmitted in any form without the expressed, written permission of Promise Technology, Inc.
Trademarks
Promise Technology and VTrak are trademarks or registered trademarks of Promise Technology, Inc. Other trademarks are the property of their respective owners.
Revision History
Version Date Author Notes
0.9 10/23/08 Mark Chauvin Initial Draft
1.0 10/27/08 Daniel Doornbos Formatting
1.1 10/30/08 Daniel Doornbos New diagrams, new explanations
![Page 3: Promise With Intel MS](https://reader031.vdocuments.site/reader031/viewer/2022020105/54084cacdab5cac8598b4887/html5/thumbnails/3.jpg)
Modular Server / VTrak Configurations
©2008 Promise Technology Inc. All rights reserved. Page 3 of 7
Overview
This document outlines the supported configurations between the Intel Modular Server (IMS) and Promise VTrak E-Class subsystem.
Promise Technology only supports the connection of the Intel Storage Controller
Module (SCM) with the Promise VTrak E310s/E610s. The connection between the SCM and VTrak is made via SAS cables with SFF-8088 Mini-SAS external
connectors. The SCM corresponds to Intel product code AXXSCM3S.
Prerequisites
In order to configure the SCM with the VTrak, the following configuration is required:
• External Port is enabled in SCM*
• LUNs are available on VTrak
• LUNs are associated with SCM initiators*
* See the IMS to VTrak E-Class Connection Guide in the Promise
Knowledgebase for setup information.
Cable Connections
The cable connections for the four supported configurations are shown on the following pages:
I. SCM to VTrak, page 4
II. SCM to VTrak with JBOD expansion, page 5
III. SCM to Cascaded VTrak, page 6
IV. SCM to Cascaded VTrak with JBOD expansion, page 7
![Page 4: Promise With Intel MS](https://reader031.vdocuments.site/reader031/viewer/2022020105/54084cacdab5cac8598b4887/html5/thumbnails/4.jpg)
Modular Server / VTrak Configurations
©2008 Promise Technology Inc. All rights reserved. Page 4 of 7
Configuration I: SCM to VTrak
Single controller connection: One SCM connected to one VTrak controller.
Dual Controller Requirements:
• LUN Affinity Disabled on VTrak.
• Intel Software Package upgraded to dual-controller.
• Use the Intel MPIO.
Do not install or use Promise PerfectPath.
![Page 5: Promise With Intel MS](https://reader031.vdocuments.site/reader031/viewer/2022020105/54084cacdab5cac8598b4887/html5/thumbnails/5.jpg)
Modular Server / VTrak Configurations
©2008 Promise Technology Inc. All rights reserved. Page 5 of 7
Configuration II: SCM to VTrak with JBOD Expansion
Up to four VTrak J310/J610 JBOD chassis can be expanded together.
![Page 6: Promise With Intel MS](https://reader031.vdocuments.site/reader031/viewer/2022020105/54084cacdab5cac8598b4887/html5/thumbnails/6.jpg)
Modular Server / VTrak Configurations
©2008 Promise Technology Inc. All rights reserved. Page 6 of 7
Configuration III: SCM to Cascaded VTraks
Up to four VTrak E310/E610 subsystems can be cascaded together.
![Page 7: Promise With Intel MS](https://reader031.vdocuments.site/reader031/viewer/2022020105/54084cacdab5cac8598b4887/html5/thumbnails/7.jpg)
Modular Server / VTrak Configurations
©2008 Promise Technology Inc. All rights reserved. Page 7 of 7
Configuration IV: SCM to Cascaded VTraks with JBOD
Expansion
In this diagram, the cascade moves to the right, expansion moves down.
Up to four VTrak E310/E610 subsystems can be cascaded together.
Up to four VTrak J310/J610 JBOD chassis can be expanded together under each subsystem.