project 16st1: ac hydraulic pump/motor

21
2018 CCEFP Georgia Institute of Technology | Marquette University | Milwaukee School of Engineering | North Carolina A&T State University | Purdue University | University of California, Merced | University of Illinois, Urbana-Champaign | University of Minnesota | Vanderbilt University Project 16ST1: AC Hydraulic Pump/Motor Mengtang Li, Graduate Student, Vanderbilt University Ryan Foss, Graduate Student, University of Minnesota Prof. Kim Stelson Prof. James Van de Ven Prof. Eric Barth photo

Upload: others

Post on 29-Oct-2021

5 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Project 16ST1: AC Hydraulic Pump/Motor

2018 CCEFP

Georgia Institute of Technology | Marquette University | Milwaukee School of Engineering | North Carolina A&T State University | Purdue University | University of California, Merced | University of Illinois, Urbana-Champaign | University of

Minnesota | Vanderbilt University

Project 16ST1:

AC Hydraulic Pump/Motor

Mengtang Li, Graduate Student, Vanderbilt University

Ryan Foss, Graduate Student, University of Minnesota

Prof. Kim Stelson

Prof. James Van de Ven

Prof. Eric Barth

photo

Page 2: Project 16ST1: AC Hydraulic Pump/Motor

22018 CCEFP

Common Fixed

Displacement Pump:

• Gear Pump

• Vane Pump

• Bent Axis Pump

• Axial Piston Pump

• Radial Piston Pump

Common Variable

Displacement Pump:

• Swash-Plate Axial Piston Pump

• Bent Axis Pump

Goal:

• Variable Displacement

• Compactness

• Simple Structure

• High Efficiency

Hydraulic Pump

Page 3: Project 16ST1: AC Hydraulic Pump/Motor

32018 CCEFP

AFH Variable Displacement Pump

Piston 1

Piston 2

(phase

adjusting)

Combined

Waveform

Piston

Stroke

Page 4: Project 16ST1: AC Hydraulic Pump/Motor

42018 CCEFP

Phase Shift = 𝟎°, Fractional Displacement = 1

Basic Idea of AFH VDP

Page 5: Project 16ST1: AC Hydraulic Pump/Motor

52018 CCEFP

Phase Shift = 𝟏𝟖𝟎°, Fractional Displacement = 0

Basic Idea of AFH VDP

Page 6: Project 16ST1: AC Hydraulic Pump/Motor

62018 CCEFP

Phase Shift = 𝟗𝟎°, Fractional Displacement = 70.83%

Basic Idea of AFH VDP

Page 7: Project 16ST1: AC Hydraulic Pump/Motor

72018 CCEFP

AFH VDP Prototype 1

3CP1120

Page 8: Project 16ST1: AC Hydraulic Pump/Motor

82018 CCEFP

AFH VDP Prototype 1

Sprocket-chain

CAT 3CP1120

Pipes connecting

cylinder chambers

Torque Sens.

Input, Output,

and Cylinder

Pressure Sens.

Output Flow Sens.

Page 9: Project 16ST1: AC Hydraulic Pump/Motor

92018 CCEFP

AFH VDP Model

• The model captures piston kinematics and cylinder pressure as

functions of the pump’s phase shift angle.

Page 10: Project 16ST1: AC Hydraulic Pump/Motor

102018 CCEFP

AFH VDP Model

• The model captures flows between pairs of

cylinders as functions of the pump’s phase shift

angle

𝑄𝑐𝑜𝑛

𝑃𝑐𝑦𝑙,1 𝑃𝑐𝑦𝑙,2𝑅, 𝐼

𝑃𝑐𝑦𝑙,1 = 𝑃𝑐𝑦𝑙,2 + ∆𝑃𝑅 + ∆𝑃𝐼

⟹ 𝑄𝑐𝑜𝑛 =1

𝐼(𝑃𝑐𝑦𝑙,1 −𝑃𝑐𝑦𝑙,2 − ∆𝑃𝐼)

Page 11: Project 16ST1: AC Hydraulic Pump/Motor

112018 CCEFP

AFH VDP Model

• The model also captures check valve dynamics†

† Knutson, A. L., Van de Ven, J. D. (2016). Modelling and experimental validation of the displacement

of a check valve in a hydraulic piston pump. International Journal of Fluid Power, 17(2), 114-124.

Page 12: Project 16ST1: AC Hydraulic Pump/Motor

122018 CCEFP

AFH VDP Model

• The model also captures input motor torque

Page 13: Project 16ST1: AC Hydraulic Pump/Motor

132018 CCEFP

AFH VDP Model

• The model also considers

(1). Leakage

(2). Viscous friction

(3). Effective bulk modulus

Page 14: Project 16ST1: AC Hydraulic Pump/Motor

142018 CCEFP

AFH VDP Model

A Dynamic Model using first principles captures

• Piston kinematics and dynamics

• Cylinder pressure

• Flows between pairs of cylinders

• Net inlet and outlet flows

as functions of the pump’s phase shift angle.

The model also captures

• Hydraulic check valve dynamics

• The effective bulk modulus

• Leakage flows

• Viscous friction

• Input motor torque

Input: Downstream Pressure, Motor Speed, Phase Shift Angle

Output: Cylinder Pressure, Flowrates*, Energy*.

Page 15: Project 16ST1: AC Hydraulic Pump/Motor

152018 CCEFP

AFH VDP Model Validation

(a) 𝜙 = 2𝑜, 250 rpm

(c) 𝜙 = 165𝑜, 250 rpm (d) 𝜙 = 165𝑜, 250 rpm

(b) 𝜙 = 2𝑜, 250 rpm

Page 16: Project 16ST1: AC Hydraulic Pump/Motor

162018 CCEFP

AFH VDP Model Validation

𝜙 = 2𝑜

250rpm

1000psi

𝜙 = 165𝑜

250rpm

1000psi

Page 17: Project 16ST1: AC Hydraulic Pump/Motor

172018 CCEFP

AFH VDP Model Validation

Results start to deviate from model

due to large dead volume.

Large dead volume, viscous

losses and friction in chain and

seals.

Page 18: Project 16ST1: AC Hydraulic Pump/Motor

182018 CCEFP

Phase Shift 1 – Differential Gear

• One wide hollow shaft (to

drive one cam) and one

narrow long shaft (to drive the

other cam).

• The differential gear set can be

placed at one side of a radial

piston pump, thus reducing the

distance between two parallel

pumping units and shortening

the connecting pipe size.

• The whole size of this phase

shift mechanism can be small.

For illustration purpose, it is

larger here.

narrow long wide hollow

Page 19: Project 16ST1: AC Hydraulic Pump/Motor

192018 CCEFP

Phase Shift 2 – Pin in Slot

Cam 1 Cam 2

* Credits go to Caroline for her great work.

Page 20: Project 16ST1: AC Hydraulic Pump/Motor

202018 CCEFP

Phase Shift 3 – Toyota Phaser

Out of PhaseIn Phase

Page 21: Project 16ST1: AC Hydraulic Pump/Motor

212018 CCEFP

Mengtang Li

[email protected]

Ryan Foss

[email protected]

Thank You!

Question?