Programmable Meter for Analog Sensors/Transducers Supply Voltage: 11-28 VDC (nominal 24 VDC) * If using a TDRO10A2 in current analog output mode 11.5-28 VDC Temperature Range: 0 to 70 C Interface: 0 to 10 V or 4 to 20 mA with over-voltage protection Resolution: 16-bit analog to digital converter Update Rate: 67 milliseconds Digital Outputs: BDD 640: No Digital Output BDD 644: Four programmable PNP outputs, 100 mA per output maximum BDD 645 Two Programmable PNP outputs, 100 mA per output maximum Analog Output: BDD 645 One 16-bit voltage / current output, 0-10V / 4-20mA, 100% adjustable Display: Six-digit LED (five-digit usable for analog display), 0.56 inches, 6-millisecond refresh rate

Upload: others

Post on 03-Oct-2020

16 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Programmable Meter for Analog Sensors/Transducersusa.balluff.com/OTPDF/855941_BDD640.pdf · 2013. 3. 13. · BDD 644: Four programmable PNP outputs, 100 mA per output maximum

Programmable Meter for Analog

Sensors/Transducers

Supply Voltage: 11-28 VDC (nominal 24 VDC) * If using a TDRO10A2 in current analog output mode 11.5-28 VDC

Temperature Range: 0 to 70 C

Interface:

0 to 10 V or 4 to 20 mA with over-voltage protection

Resolution: 16-bit analog to digital converter

Update Rate:

67 milliseconds

Digital Outputs: BDD 640: No Digital Output BDD 644: Four programmable PNP outputs, 100 mA per output maximum BDD 645 Two Programmable PNP outputs, 100 mA per output maximum

Analog Output:

BDD 645 One 16-bit voltage / current output, 0-10V / 4-20mA, 100% adjustable

Display: Six-digit LED (five-digit usable for analog display), 0.56 inches, 6-millisecond

refresh rate

Page 2: Programmable Meter for Analog Sensors/Transducersusa.balluff.com/OTPDF/855941_BDD640.pdf · 2013. 3. 13. · BDD 644: Four programmable PNP outputs, 100 mA per output maximum

Programming Capability: Zero and Span are 100% adjustable Number of digits displayed and decimal point Programmable switch-point for each digital output Analog output is 100% adjustable

Compact 1/8 DIN housing, panel mountable and IP65/Nema 4 ingress protection

Accuracy:

0.075% of reading typical, 0.15% max (+/- 1 digit count)

Current Draw: BDD 640 = 9.5 mA (maximum)

BDD 644 = 9.5 mA (Base Meter)

+ 400 mA (4 * 100 mA, Digital Outputs) 409.5 mA (maximum)

BDD 645 = 9.5 mA (Base Meter) In voltage + 200 mA (2 * 100 mA, Digital Outputs) output mode + 1 mA (Analog voltage output into high impedance input >1 MΩ) 210.5 mA (maximum)

BDD 645 = 9.5 mA (Base Meter) In current + 200 mA (2 * 100 mA, Digital Outputs) output mode + 20 mA (Analog current output) 229.5 mA (maximum)

Page 3: Programmable Meter for Analog Sensors/Transducersusa.balluff.com/OTPDF/855941_BDD640.pdf · 2013. 3. 13. · BDD 644: Four programmable PNP outputs, 100 mA per output maximum

INDEX TO PROGRAM GENERAL PARAMETERS FOR ANALOG METER 3 TO PROGRAM DIGITAL OUTPUT SETPOINTS 6 TO PROGRAM ANALOG OUTPUT (RE-TRANSMISSION) SETPOINTS 8 TROUBLESHOOTING THE ANALOG METER 11 SETTING THE JUMPERS FOR VOLTAGE OR CURRENT OUTPUT 12 POWER AND I/O CONNECTOR PINOUT 12 PANEL CUTOUT 13 METER INSTALLATION 13 METER DIMENSTIONS 13

Page 4: Programmable Meter for Analog Sensors/Transducersusa.balluff.com/OTPDF/855941_BDD640.pdf · 2013. 3. 13. · BDD 644: Four programmable PNP outputs, 100 mA per output maximum

TO PROGRAM GENERAL PARAMETERS FOR ANALOG METER:

1. Press the “PROG.” and “↑” buttons at the same time. 2. The meter will read “CAL” (Calibrate); press “↑” to select “Yes,” and press “Prog.” to continue.

(To cancel: press “↓” to select “No,” and press “Prog.”)

3. Next, the meter will alternate between “CAL IN” and “CAL OU” (Calibrate Input & Calibrate

Output, respectively). At this point the input calibration (“CAL IN”) will be discussed. The analog output calibration section discusses the “CAL OU” function. Press “↑” to select “CAL IN,” and press “Prog.” to continue.

4. The meter will alternate between “DEC PT” (decimal point) and a number showing the current

location of the decimal point a. Press “PROG.” to skip changing the decimal point b. Press “↑” or “↓” to move the decimal point up or down; when finished, press and hold

“PROG.” for one second to end.

Page 5: Programmable Meter for Analog Sensors/Transducersusa.balluff.com/OTPDF/855941_BDD640.pdf · 2013. 3. 13. · BDD 644: Four programmable PNP outputs, 100 mA per output maximum

5. The meter will alternate between “ZERO” and the value of the zero point a. Press “PROG.” to skip changing the zero point b. Press “↑” or “↓” to change the zero point

i. Move the transducer to the desired zero position ii. Press “↑” or “↓” to increase or decrease each digit iii. Press “PROG.” quickly to program the next digit iv. When finished, press and hold “PROG.” for one second to end

6. The meter will alternate between “SPAN” and the value of the span point

a. Press “PROG.” to skip changing the span point b. Press “↑” or “↓” to change the span point

i. Move the transducer to the desired span position ii. Press “↑” or “↓” to increase or decrease each digit iii. Press “PROG.” quickly to program the next digit iv. When finished, press and hold “PROG.” for one second to end

Page 6: Programmable Meter for Analog Sensors/Transducersusa.balluff.com/OTPDF/855941_BDD640.pdf · 2013. 3. 13. · BDD 644: Four programmable PNP outputs, 100 mA per output maximum

TO PROGRAM DIGITAL OUTPUT SETPOINTS:

1. Press the “PROG.” and “↓” buttons at the same time. 2. The meter will alternate between “SETPT1” and the current set-point

a. Press “PROG.” to skip to the next digit; press “↑” or “↓” to change the value of that digit. b. When finished, press and hold “PROG.” for one second to end.

The illustration below shows how to accept the current value (25.00 in this example)

3. Press “PROG.” to move to the next set-point (“SETPT2”). The meter will alternate between “SETPT2” and the current set-point (30.00 in this example)

a. Press “PROG.” to skip to the next digit; press “↑” or “↓” to change the value of that digit. b. When finished, press and hold “PROG.” for one second to end.

The illustration on the next page shows the exact sequence of changing digital output 2 (“SETPT2”) from 30.00 to 40.00.

Notice that pressing the “Prog.” button changes which digit flashes on and off. This flashing digit is the “selected digit” (similar to a cursor in a word processor). To change its value, simply press either the “↑” or “↓” button. To go to the next digit simply tap the “Prog.” Button. When the desired value has been entered, Press and hold the “Prog.” Button. When the actual position is above the “SETPT1” position, the digital output 1 will activate and the

“SP1” LED will illuminate (Similarly with “SETPT2” and “SP2” LED).

Page 7: Programmable Meter for Analog Sensors/Transducersusa.balluff.com/OTPDF/855941_BDD640.pdf · 2013. 3. 13. · BDD 644: Four programmable PNP outputs, 100 mA per output maximum
Page 8: Programmable Meter for Analog Sensors/Transducersusa.balluff.com/OTPDF/855941_BDD640.pdf · 2013. 3. 13. · BDD 644: Four programmable PNP outputs, 100 mA per output maximum

TO PROGRAM ANALOG OUTPUT (RE-TRANSMISSION) SETPOINTS: The analog output is a fully scalable linear output that can be programmed in units of position vs. current or voltage, dependant upon the jumper setting on the rear of the unit. (see “setting the jumpers for voltage or current output” section). The illustration to the right shows an example where the desired output is 4 mA at 50mm and 20 mA at 150mm. Notice that when the position reaches 100mm the current output will be 12 mA. The positions are labeled “OUH SP” and “OUL SP” for Output High Set-point and Output Low Set-point, respectively. This nomenclature will be referenced as you are programming the analog output. The current values are labeled “OUL VL” and “OUH VL” for Output Low Value and Output High Value, respectively. These will also be referenced as you are programming the analog output.

1. Press the “PROG.” and “↑” buttons at the same time. 2. The meter will read “CAL” (Calibrate); press “↑” to select “Yes,” and press “Prog.” to continue.

(To cancel: press “↓” to select “No,” and press “Prog.”)

3. Next, the meter will alternate between “CAL IN” and “CAL OU” (Calibrate Input & Calibrate Output, respectively). At this point the analog output calibration (“CAL OU”) will be discussed. Press “↓” to select “CAL OU,” and press “Prog.” to continue.

Page 9: Programmable Meter for Analog Sensors/Transducersusa.balluff.com/OTPDF/855941_BDD640.pdf · 2013. 3. 13. · BDD 644: Four programmable PNP outputs, 100 mA per output maximum

4. The meter will alternate between “V” and “A” for Volts and Amps, respectively. This selects

whether the analog output programming scale will be from 0 to 10 Volts (“V”) or 4 to 10 milliamps (“A”).

a. Press “Prog.” After making your selection. b. Note: The jumper on the rear of the unit determines which mode (0 to 10 Volts or 0 to 20

mA) the meters output is actually in. (see “setting the jumpers for voltage or current output” section).

5. Next, the meter will alternate between “OUL SP” (Output Low Set-point, see analog output scaling graph) and the current set-point

a. Press “PROG.” to skip to the next digit; press “↑” or “↓” to change the value of that digit. Repeat until the desired number has been achieved.

b. When finished, press and hold “PROG.” for one second to end.

6. Next, the meter will alternate between “OUL VL” (Output Low Value, see analog output scaling

graph) and the current set-point a. Press “PROG.” to skip to the next digit; press “↑” or “↓” to change the value of that digit.

Repeat until the desired number has been achieved. b. When finished, press and hold “PROG.” for one second to end

Page 10: Programmable Meter for Analog Sensors/Transducersusa.balluff.com/OTPDF/855941_BDD640.pdf · 2013. 3. 13. · BDD 644: Four programmable PNP outputs, 100 mA per output maximum

7. Next, the meter will alternate between “OUH SP” (Output High Set-point, see analog output scaling graph) and the current setpoint

c. Press “PROG.” to skip to the next digit; press “↑” or “↓” to change the value of that digit. Repeat until the desired number has been achieved.

d. When finished, press and hold “PROG.” for one second to end

8. Next, the meter will alternate between “OUH VL” (Output High Value, see analog output scaling

graph) and the current set-point e. Press “PROG.” to skip to the next digit; press “↑” or “↓” to change the value of that digit.

Repeat until the desired number has been achieved. f. When finished, press and hold “PROG.” for one second to end

Page 11: Programmable Meter for Analog Sensors/Transducersusa.balluff.com/OTPDF/855941_BDD640.pdf · 2013. 3. 13. · BDD 644: Four programmable PNP outputs, 100 mA per output maximum

TROUBLESHOOTING THE ANALOG METER: The meter has two special modes to help determine if an unexpected reading or analog output is due to the setup programming (scalable inputs and outputs) or if there is an actual problem with the meter. The first mode allows the raw input (either voltage or current) to be displayed on the screen. At this point the meter acts like a digital voltmeter. This allows the user to “see” what voltage the meter is reading. Example:

Input: linear transducer, 100mm stroke, 0 to 10V output. Input Scaling: Set up to read in mm (0 to 100mm)

Analog Output: 0 volts @ 0.0mm, 10 volts @ 50.0mm When the transducer is at the midpoint of the stroke the display should read 50.0 and the input voltage (across pins 6 and 7) should be 5.0 volts. In order to show the input voltage or current on the display press and hold “↑” for 5 seconds

To go back to the normal display mode press and hold “Prog.” for 5 seconds.

The second mode allows the raw output to be displayed on the screen. This option is only valid for meters that have the analog retransmission capability (BDD 645-R3A-5-53-E-00). This allows the user to “see” what output voltage the meter is supplying. Using the setup from the example from above, when the transducer is at half of the stroke (50mm) the display should read 50.0, the input voltage (across pins 6 and 7) should be 5.0 volts and the analog output voltage (between pins 1 & 2) should be 10.0V (since the analog Output was set to 0 volts @ 0.0mm and 10 volts @ 50.0mm). In order to show the output voltage or current on the display press and hold “↓” for 5 seconds

To go back to the normal display mode press and hold “Prog.” for 5 seconds.

Page 12: Programmable Meter for Analog Sensors/Transducersusa.balluff.com/OTPDF/855941_BDD640.pdf · 2013. 3. 13. · BDD 644: Four programmable PNP outputs, 100 mA per output maximum

SETTING THE JUMPERS FOR VOLTAGE OR CURRENT OUTPUT:

1. Locate the jumper (shown below) on the rear of the unit. 2. For voltage output (0 to 10 V), place the jumper around the left and center pins. 3. For current output (0 to 20 mA), place the jumper around the right and center pins.

POWER AND I/O CONNECTOR PINOUT: The connector is located on the rear of the unit and is numbered from left to right as shown in the illustration below.

PINOUT FOR ANALOG VERSION Pin 1: Ana. Out – (BDD 645-R3A-5-53-E-00) or Dig. Out#4 (BDD 644-R3A-0-54-E-00) Pin 2: Ana. Out + (BDD 645-R3A-5-53-E-00) or Dig. Out#3 (BDD 644-R3A-0-54-E-00) Pin 3: Dig. Out #2. Pin 4: Dig. Out #1 Pin 5: 4-20 mA Input Pin 6: 0-10 V Input Pin 7: Ground Pin 8: 10 V Ref. Pin 9: Ground Pin 10: +24 V Trans. Pin 11: Ground Pin 12: +24 V Sup.

Page 13: Programmable Meter for Analog Sensors/Transducersusa.balluff.com/OTPDF/855941_BDD640.pdf · 2013. 3. 13. · BDD 644: Four programmable PNP outputs, 100 mA per output maximum

PANEL CUTOUT: The meter mounts into a standard 1/8 DIN cutout. The illustration below shows the suggested panel cutout.

METER INSTALLATION: Insert the meter into the panel cutout described above. Make sure that the unit has been fully inserted and is flush with the panel face taking care with the rubber gasket provided. You may have to manipulate the gasket a bit to get the corners to line up reasonably close. Install the provided mounting clips from the rear of the unit as shown below. Make sure that the clips are locked in to the side of the meter. Tighten the mounting screws until the meter is secure. Do not over tighten the screws.

METER DIMENSIONS:

Doc

. No.

855

941

/Mat

. No.

15

717

1

E E

ditio

n 11

11

Sub

ject

to m

odifi

catio

n w

ithou

t not

ice

Rep

lace

s E

ditio

n 07

07