production of polychlorinated dibenzo-p-dioxins (pcdd) and ... · production of polychlorinated...
TRANSCRIPT
PRODUCTION OF POLYCHLORINATED DIBENZO-p-DIOXINS (PCDD) ANI) DIBENZO NS (pCDF)
FROM RESOURCE RECOVERY FACILITIES PART 1. SOURCES, EMISSIONS AND AIR
QUALITY STANDARDS
STEPHEN J. GRAHAM, DANA C. PEDERSEN, DONALD M. POMPELlA, and EDWARD P. KUNCE
Camp Dresser & McKee Inc. Boston, Massachusetts
ABSTRACT
An overview of measured PCDD/PCDF emissions and of sources and proposed mechanisms for the appearance of PCDD/PCDF in U.S. and European recovery facilities is provided. Observed health effects, and existing standards or guidelines for ambient acceptable levels, of PC DO/PC OF are presented. Furture research needs are identified.
INTRODUCTION
Recent media coverage of dioxin contamination in road dust suppressant oil in Times Beach and other towns in Missouri, and jn soil and buildings adjacent to chlorophenol factories (e.g., Dow Chemical in Midland, MI) has made "dioxin" practically a household word in the United States.
The term "dioxins" has been used to refer to a class of organic compounds that are considered among the most toxic known to man. "Dioxins" are actually polychlorinated dibenzo-p-dioxins (PCDD), tricyclic aromatic compounds with a central 1,4-dioxane ring. Chlorine atoms can theoretically attach to dibenzo-p-dioxin at any one of the sites enumerated in Fig. 1. The addition of from one to eight chlorine atoms can form eight homologues with up to 75 different isomers; only 22 have been identified or synthesized to date [1, 2] . Closely related to PCDD are polychlorinated dibenzofurans (PCDF), which have generally been neglected by the press, but since certain PCDF isomers approach PCDD in potential toxicity and originate Similarly it is appropriate to discuss them here also. Furans are similar in structure to dioxins but have a five-sided ring core containing only one oxygen (Fig. 1). The loci and nomenclature for chlorine addition to dibenzofuran
345
parallels that for PCDD (Table 1). Because of irregular configuration 135 PCDF isomers are possible, but only 38 are known to exist [3, 13] .
THE PROBLEM
Some municipal resource recovery facilities and incinerators in Europe [2-8], Japan [9], the United States [10-13] , and Canada [9, 14] have been reported to emit PCDD and/or PCDF. Concentrations in flue gas, particulates, and fly ash have generally ranged from <0.1-100 ugf kg, varying with sampling apparatus and methodology, waste composition, and operating conditions. Facilities in Europe, particularly the Netherlands, have shown emissions an order of magnitude higher than those found in North America [6, 15, 16].
A November 1981 EPA study [11] of five United States plants, including RDF, co-combustion with coal, and mass-burn units, concluded that these facilities' emisions for 2,3,7,8-TCDD, the most toxic PCDD isomer, did not present a public health hazard for residents living in the immediate vicinity [11, 12]. Certain in -stack and ground-level concentrations of total TCDD were calculated. New York State in November 1982 adopted the total TCDD ground-level concentration from that report as an acceptable ambient level of TCDD [83]. Canada and the Netherlands have recently established guidelines for acceptable concentrations of 2,3,7 ,8-TCDD for both total PC DO and PCDF based on ambient levels and potential daily intake, respectively [82, 84] . Given the increasirig concern over the occurrence of PCDD and PCDF, it is imperative that government and the public have accurate and adequate information upon which to base regulatory
9 o
o 6 4
PCDD
x,y=1-4
9
o 6 4
PCDF
FIG. 1 PCDD AND PCDF CHEMICAL STRUCTURE
EQUATION 1 OH 0 -HC I 0 CI CI ...... CI or CI -
a.) 0 -Hel ) 0 0 -NaG I ) 0 0 CI CI CI CI OH CI CI 0 (ONa)
CI 0 CI
b.) 0 NaOH) -NaCI CI Cl CI
CI CI CI
Formation of 2, 3, 7, 8 TCDD from chlorophenols by
a.} Chlorination of phenols
b.} Alkaline hydrolysis of chlorobenzenes
EQUATION 2 �� o- CI�:::;;" Clx
CI 0-t;:, )
Two chlorophenol ate molecules A PCDD
CI
CI
action and assess environmental impact. Towards that objetive this paper reviews current information on PCDD/ PCDF origin and emissions in resource recovery facilities, and observed health effects and current guidelines for ambient concentrations with regard to protection of public health. The discussion contained herein (part I) provides background for engineering evaluation of the potential for incinerators and resource recovery facilities to generate PCDD/PCDF (part II).
SOURCES OF PCDD/PCDF
Chlorinated dioxin and furan emissions from resource recovery facilities appear to: (1) result from volatilization of PCDD/PCDF present as artifacts in chemicals in the combusted refuse, hence originate from non-combustion sources; and (2) form under combustion conditions via reactions involving chlorinated and perhaps also nonchlorinated organic compounds [5] .
NON-COMBUSTION SOURCES OF PCDD/PCDF
Commercial manufacture and processing of chlorobenzenes, polychlorinated biphenyls (PCBs), and chlorinated phenols and their derivatives - phenoxy acid herbicides and pesticides, and diphenyl ethers - have not uncommonly generated PCDD and/or PCDF as trace impurities (Table 2). Agricultural residues, household discards (e.g., cleaners, insecticides), and certain industrial waste fractions (e.g. treated wood, PCB containers) may contribute quantities of these commercial artifacts to the refuse processed by resource recovery facilities [1, 5] . PCDD/PCDF introduced into municipal solid waste (MSW) in this manner could volatilize or adhere to particles upon combustion to some unknown degree and exit a facility to the surrounding environment [1, 10] .
Dimerization (ring formation) of chlorophenols to form PCDD
Researchers disagree as to how much PCDD/PCDF ends up in MSW prior to combustion. Some researchers citing their work on Italian MSW stated that these substances are most likely only minor constituents of domestic refuse [22]. However, others [5, 20] have noted the lack of systematic studies to confirm or deny this. It is wellknown that the MSW of many U.S. and northern Europe cities contains a significant industrial fraction, in contrast to Italian MSW with its higher agricultural waste content [23] . A major problem encountered in comparing MSW is their extreme variation due to differences in climate, culture, socioeconomics and method of sampling and waste processing [24] .
EQUATION 3
CI. OH ) PCDD
Thermal cyclization Of polychlorinated phenoxyphenols
to form PCDD
346
The presence of PCDDjPCDF in commercial chemicals is described below.
Manufacture of PCBs
Commerical polychlorinated biphenyl solutions can contain over 100 PCB isomers with varying numbers of chlorine atoms [17]. PCBs have been found to contain PCDFs as trace impurities [8, 18] . PCB manufacture was prohibited in the United States after 1976 and its current limited use and disposal is strictly regulated [2S] .
Manufacture of Chlorophenols
Chlorophenols, typically produced by: (a) chlorination of phenols; or (b) alkaline hydrolysis of chlorobenzenes, can contain PCDD as a result of either reaction, as shown in Equation 1 [29] .
Generally the PCDD formed will contain one chlorine atom more than the initial substrate possessed; i.e., trichlorophenol manufacture forms TCDD, tetrachlorophenol production forms mostly PnCDD or HxCDD (at levels from <1-100 ppm by weight of initial tetrachlorophenol), and pentachlorophenol manufacture produces HxCDD or higher chlorinated phenols. Chi oro phenols and their salts, the chlorophenolates, are used as fungicides, herbicides, slimacides, bactericides, and in the manufacture of chlorinated phenoxy acid herbicides such as 2,4,S-T and 2,4-D and the bactericide hexachlorophene. Chi oro phenols can contain polychlorinated phenoxyphenols, diphenylesters, PCDD, and PCDF as artifacts. Tetra-, penta-, and hexa-
CDD have been found in trio, tetra-, and pentachlorophenol and their salts in concentrations ranging up to 100 ppm [18, 26-33].
PCDD content in commerical chlorophenols and derivatives varies according to manufacturing process and conditions [32]. U.S. production of chlorophenol and its derivatives continued as of 1982 in over 20 states at nearly 100 locations. Manufacturer awareness has generally decreased PCDD content to <0.1 ug/g in 2,4,S-T [32]. Chlorophenol use is banned in Sweden [34] .
Manufacture of Polychlorinated Benzenes
Hexachlorobenzene, a wheat fungicide, and various chlorinated benzenes, common industrial solvents and chemical manufacture feedstocks, have been noted to contain trace PCDD [1, 3 S] .
Manufacture of Chlorophenoxy Acids and
Hexachlorophene
Manufacture of the chlorophenol derivatives chlorophenoxy acid pesticides and herbicides, such as 2,4,S-T, and hexachlorophene, a bactericide, also have produced PCDD as contaminants [1]. TCDD, including the 2,3,7,8-isomer, and HxCDD are formed; Agent Orange, derived from 2,4-S-T and the defoliant used by the U.S. Army in
TABLE 1 NOMENCLATURE AND TOTAL NUMBER OF THEORETICAL PCDD AND PCDF ISOMERS [1,121
•
Monochlorinated
Dichlorinated
Trichlorinated
Tetrachlorinated
Pentachlorinated
Hexachlorinated
Heptachlorinated
Octachlorinated
.
Dibenzo-p-dioxin Possible No.
Homologue Isomers
2
-DCDD 10
-TrCDD 14
-TCDD 22
-PnCDD 14
-HxCDD 10
-HpCDD 2
-OCDD 1
•
347
Di benzofuran Possible No.
Homologue Isomers
4
-DCDF 16
-TrCDF 28
-TCDF 38
-PnCDF 28
-HxCDF 16
-HpCDF 4
-OCDF 1
w
"""
00
TA
BL
E 2
COM
ME
RC
IAL
CH
EM
ICA
LS
WH
ICH
CO
NT
AIN
PC
DD
AN
D/O
R P
CD
F A
S M
AN
UF
AC
TU
RIN
G O
R P
ROC
ES
SIN
G A
RT
IFA
CT
S
Chem
ica
l Cl
ass
1.
Poly
chlo
rina
ted
bip
heny
ls
(PCB
s)
2.
Chlo
roph
enol
s:
1ric
hlor
ophe
nol,
1r
ichl
orop
heno
late
letr
achl
orop
heno
l
Pent
achl
oro
phen
ol,
Pent
achl
orop
heno
late
3.
Chlo
robe
nzen
e:
�ex
achl
orob
enze
ne
(�CB
)
Misc
. Ch
loro
benz
enes
4.
Chlo
rina
ted
phe
noxy
aci
ds
(Chl
orop
heno
l d
eriv
ativ
es):
5.
Erbo
n Si
hex
2,
4,5-
1 2,
4-D
�ex
achl
orop
hene
(C
hlor
ophe
nol
der
ivat
ive)
6.
Poly
chlo
rina
ted
Pi p
heny
l Et
hers
(l
rich
loro
phen
ol d
eriv
ativ
e)
Repr
esen
tati
ve S
truc
ture
Cl y
Clx �
OH
�O-
Clx
Clx
OH
CI 0
•
CI
Clx
A
�
�OC
H2CO
OH
OH
• CI
O� CI x
= 1
-5 o
r 6
y =1-
5
Exam
ple
Use
Cool
ant,
in
sula
nt
Wood
, le
athe
r pr
eser
vati
ve
(ins
ecti
cid
e)
Fung
icid
e in
pap
er p
ulp
manu
fact
ure;
ba
cter
icid
e
�ddi
tive
to
cutt
ing
flui
ds
and
oils
, pa
int,
gl
ue,
text
iles
, d
yes,
pi
gmen
ts
Fung
icid
e in
(w
heat
) In
dust
rial
sol
vent
s
Pest
icid
e Pe
stic
ide
�er
bici
de
flerb
i ci
de
Bact
eric
ide
us
ed
in s
oaps
, sh
ampo
os,
etc.
, un
til
re
stri
cted
by
the
U.S.
FP
� •
flerb
i c i
des
Refe
renc
e
1,17
,18,
28
1,26
1,26
,27,
29,3
2,33
1,26
,27,
30,3
2,33
1,35
1,
35
1 1 1,27
,211
1,27
,36
1,29
1,19
Vietnam, was contaminated in the 1960s by 2,3,7 ,8-TCDD from this source [29] .
Hexachlorophene is produced from the same starting material as 2,4,5-T but due to additional purification 2,3,7,8-TCDD in this product is <0.03 ug/g [29]. 2,4-D has been reported to be contaminated with PCDD but only as a result of using 2,4,5-T contaminated processing equipment [37] .
Manufacture of Diphenyl Ether Herbicides
TCDD, PnCDD and HxCDD have been reported as contaminants in diphenyl ether herbicides; concentrations of the latter two species were found up to 150 and 30 ppm, respectively [19]. No 2,3,7 ,8-TCDD was detected.
COMBUSTION SOURCES OF PCDD/PCDF
Chlorinated dioxin and furan emissions from resource recovery facilities that result from combustion system conditions appear to occur either from reactions of chlorinated aromatic "precursors" alone or in combustion with other precursors; and have also been suggested to form from "de novo"* synthesis of reaction contributors, chlorinated aliphatic and non chlorinated aromatic compounds which combine to form PCDD/PCDF [5, 20]. Reaction contributors have also been suggested to donate compounds to precursor reactions. Based on comparative thermokinetics, PCDD/pcDF formation appears more readily accomplished from precursor reactions rather than de novo synthesis [20] .
Precursors
Precursor compounds identified thus far are chlorinated aromatic compounds usually containing various hydroxyl groups or ether linkages (Table 2). Postulated and synthetically created reactions identified to date for PCDD/ PCDF formation from precursors are discussed below.
PCBS
Ambient quantities of polychlorinated biphenyls in the U.S. have decreased dramatically in the past decade due to regulatory action, but discarded PCB-containing condensors (e.g., fluorescent lighting ballast), capacitors (in air
''''de novo" synthesis is the formation of PCDD and/or PCDF "as
a consequence of a complex array of pyrolytic processes of chemically unrelated organics" such as PVC; other nonchlorinated plastic polymers; coal; wood (lignin); non-benzene chlorocarbons; and inorganic chlorine compounds such as HCI, Nacl, or CI. [20].
349
conditioners, some refrigerators, television sets, and stereos), and miscellaneous electrical equipment mostly manufactured prior to 1972 still end up in MSW [36, 38]. Discarded PCB has been suggested as a potential major source of PCDF either through volatilization of artifacts or direct formation [8]. Support for this theory was claimed from the similarity of GC/MS analyses of PCB pyrolysate from sealed quartz ampoules to incinerator and utility boiler fly ash in Switzerland, verified to contain PCDF. Various tri-through heptachlorobiphenyls were found to form mono- through hexa-PCDF by rearrangement and/or dechlorination and oxyenation, in concentrations up to 2 percent. 2,3,7 ,8-TCDF was reported as a major isomer [8]. Incineration of PCB between 1247-1832°F (675-1000°C) showed that hexachlorobenzenes (HCB) production increases with increasing temperature, from 2 up to 35 mg HCB/kg PCB [34] . EPA-sponsored high temperature PCB destruction tests aboard the M/T Vulcanus found a conversion of up to 0.0025 percent to tetra-CDD and tetra-CDF at >1200-2200°F (>650-1204°C) and >1 sec residence time [39]. Laboratory analyses showed destruction efficiencies of 99.995 percent at 1472°F (800°C) and a 2 sec residence time [39] and PCB destruction appears to be complete at incineration temperatures above 2192-2552°F (1200-1400°C) [40]. Tests conducted at EPA-licensed PCB incinerators in Deer Park, Texas and El Dorado, Arkansas revealed the presence of "very low levels of PCD!) and PCDF" in samples [38] . Tests at each facility in 1979 and 1980 found PCDF only in 1980, at levels of 0.281 and 0.060 ng/dscf. PCDD was sampled for in 1980 at each facility and found at levels of 0.018 and 0.005 ng/dscf. Average incinerator temperatures at both facilities during all tests exceeded 2147°F (1175°C) [38]. Cement kilns in the U.S. [38] and Sweden [44] operating at high temperatures, >2192°F (>1200°C), were not observed to produce PCDD/PCDF or other high molecular weight chlorinated organics from PCB feedstocks.
Chlorophenols and Chlorophenolates
Chlorophenols and chlorophenolates evidently can convert to PCDD and/or PCDF or precursors under sufficient heat. A total of 385 ug/g of tri- and 856 ug/g of tetrachlorophenol mixed with wood chips was introduced into a pilot-scale incinerator at 932-1112°F (500-600°C) in Europe. PCDD production decreased with increasing' temperature 1112°F (>600°C), copper salts addition, increased residence time, and increased combustion oxygen. Temperature appeared to exert greater influence on PCDD production than oxygen presence and <35 ug/g of all isomers was found at 1544°F (840°C) and similar combustion conditions for tri- and tetrachlorophenol
[34] . Pentachlorophenol reacted under similar conditions in the same incinerator to generate "small PCDD emissions" except where oxygen was deficient . No TCDD was formed at IS62°F (8S0°C) from pentachlorophenol [34] .
Chlorophenolate-coated wood and leaves when openburned have yielded various PCDD. Combustion of trichlorophenolate produced mostly TCDD, while pentachlorophenolate produced mostly OCDD [29]. Dimerization of chlorophenols or their salts (Eq. 2) and dechlorination of higher chlorinated PCDD to form less chlorinated isomers have been advanced as PCDD formation mechanisms from this [29] and other work [S, 33] . The pyrolysis of polychlorinated phenoxy phenols and their salts, which are commercial trichlorophenol impurities, was observed to generate TrCDD and PnCDD by thermal cyclization (ring closure), seen in Eq. (3). PCDD formation in increased from 0.4 percent to 9.06 percent yield by weigh t as temperatures increased from 677°F to 1796°F (3S8°C to 980°C) [21] . 2,3,7 ,8-tetra-CDD has been suggested as forming only from dechlorination or cyclization [29] .
Chlorinated Phenoxy Acids
PCDD has been reported to be formed at a yield of O.OOOS percent from open-burning 2,4,S-T and related phenoxy acids [43]. A similar study on a 2,4,S-T ester (2-butoxyethyl) observed only TCDD to be produced from temperatures of 212 - 1247°F (100 - 67SOC) at a 0.0001 percent yield [44]. From these experiments, 1382°F (7S0°C) was suggested as the optimal temperature for PCDD production from 2,4,S-T and related compounds; lower temperatures formed less PCDD and higher temperatures, 1472°C (>800°C), destroyed PCDD [10].
Chlorobenzenes
Pyrolysis of trio, tetra- and pehtachlorobenzenes in sealed quartz ampoules at 1 148°F (620°C) in air generated PCDD and PCDF via thermal oxidation in yields of O.OOOS percent and 0.0001 percent by weight, respectively [4S]. 2,3,7 ,8-TCDD and other especially toxic isomers were present in minor concentrations, as were chlorophenols and PCBs. The yields are expected to be much less if lower concentrations of starting material were used [20]. No correlation to municipal incinerator operation of PCDD/PCDF formation from chlorobenzenecontaminated MSW has been suggested from these results [S] , but the source separation of industrial chlorobenzenes from MSW has nonetheless been recommended [4S]. Other researchers found no increase in either PCDD or PCDF from the addition of a 400 g slug of hexachlorobenzene to 2 m3 of MSW in a municipal incinerator [46]. A review [20] of several independent pyrolysis reactions
3S0
involving chlorobenzene has shown that significant HCI and some chlorinated biphenyls and naphthalene form at < 1472°F (>800°C), but at >1472°F (>800°C) vinyl chloride is the main product and at the least biphenyls concentration is reduced .
Polychlorinated Diphenyl Ethers
Polychlorinated hydroxy diphenyl ethers (PCDPE) as contaminants in chlorophenols were suggested to generate PCDD via cyclization [29]. It is has been reported that 2,3,7,8-TCDD may be formed from pyrolysis of these PCDPE. 2S percent of these compounds decomposed at 932°F (SOO°C), 99 percent at 1292°F (700°C); PCDD formed only upon dechlorination of ortho-chlorinated compounds [4S] .
Synthetic Precursor Combination
PCDD has been produced synthetically in the laboratory from various precursors in attempts to elucidate TCDD formation [1]. The relevance of these reactions to field conditions is unknown. Catechol salts have been reacted with o-dichlorobenzenes in dimethyl sulfoxide to yield 19 percent PCDD [1] . Dibenzo-p-dioxin has been reacted with Cl2 and FeCl3 to produce a mixture of tri- through penta-CDD, although 2,3,7 ,8-TCDD was in low yield. Much higher yields of 2,3,7 ,8-TCDD were reported (>40 percent) from reaction of Cl2 alone or with FeCl3 and 12 but no Ch [1].
Photo production
Ul traviolet irradiation of OCDD has produced small amounts of mixed trio, penta-, hexa-, and hepta-CDD [1] . The role of photolysis in PCDD/PCDF decomposition, and the resulting dechlorination of higher chlorinated homologues (e.g., OCDD) to lesser chlorinated, more toxic isomers has been the focus of considerable research [46] .
Reaction Contributors
A variety of chlorinated aliphatic and non-<:hlorinated aromatic compounds have been proposed to combine via de novo [1] synthesis to produce PCDD/PCDF or form certain precursors, notably chlorobenzene and chlorophenols. Inorganic chlorine compounds have also been suggested to contribute chlorine to non-chlorinated aromatic compounds at sufficient temperature to generate PCDD/PCDF [S, 20] .
Chlorinated Aliphatics
Polyvinyl chloride (PVC) plastics are known to produce various aromatic and aliphatic compounds upon PVC thermal degradation, in addition to gaseous HCl, CO, and CO2 [48]. Chlorinated benzenes (precursors) are produced and reactive chlorine (HCI) released which under high temperatures could substitute to precursors [5, 20]. Although original work on PVC combustion emissions in the late 1960s revealed no PCDD or PCDF [47], analytical methodology at that time could rarely measure chemical concentrations <0.1 ppm. Pyrolysis of PVC has been observed to generate various benzenes and HCI as the major organic and inorganic products, respectively [20]. Various chlorobenzenes have been reported from PVC pyrolysis [20] but apparently concentrations resulting have been <1 ppm where oxygen is present [5] . Other pyrolysis experiments occurring from 1022-2012°F (550-1100°C) measured vinyl chloride and di- through hexachlorobenzene (HCE) production. Total organic bound chlorine increased with temperature up to 50 ug/g, over half of which was HCB [34]. Quantitative conversion of >90 percent PVC chlorine to HCl has been observed during direct combustion 1300-1600°F (704-871°C) of MSW 24 percent PVC by weight [48]; during pyrolysis it has been estimated that quantitative conversion occurs above 572°F (300°C) [49, 50] . PVC is typically 45 percent chlorine by weight. Chlorine gas (Ch) or phosgene (COCh) have not been detected from PVC combustion [48] .
PVC plastic has been theorized as a chlorine donor (HCl) to phenols and polyphenols to account for the production of PCDD and PCDF from incineration of raw MSW in Italy [22] . Incineration of agricultural waste or "recycled" or compost residue fractions of the MSW produced no PCDF and fewer PCDD isomers, in concentrations ranging from 140 ppb, an order of magnitude lower. This difference was said to occur because in the non-MSW fractions either phenol-generating tannin or chlorinedonating plastics were absent [22]. Acceptance of this argument should be withheld pending further characterization of the four waste streams. The large quantity of raw cellulose (containing lignin) probably common in each of those wastes could readily replace tannin as a phenol donor. Also it would be most unusual if the "chlorine-donating plastics" (and paper, rubber, textiles, leather, etc., potentially containing chlorine, PCDD/PCDF artifacts, or precursors) found in raw MSW were not also present in both recycled and compost wastes, according to waste analyses from other Italian provinces and northern Europe [23, 51]. Further discussion of this point is provided elsewhere [52] .
The role of PVC plastics, and other MSW components, as potential HCI donors to precursors and nonchlorinated
351
aromatics should be further investigated given the current attention. PVC is widely employed, comprising 15.2 percent of total U.S. plastics consumption in 1981 [53] and predominating in use by type of plastic in the Netherlands in 1975 [54]. However, because PVC is found predominantly in durable goods, such as piping, construction products, and automobile upholstery, it generally does not end up in MSW, although an occasional bleach bottle or vinyl record, toys, etc., will. PVC markets in the U.S. have reached maturity, increasing in sales by <4 percent for each of the last 5 years but decreasing in total percentage of all plastics since 1977 [53]. Other common refuse products can contain chlorine which could also convert to HC!. Paper (e.g., newsprint) can contain from 0.04-0.16 percent chlorine, almost all of which is supposedly completely expelled upon burning [55]. In Detroit, textiles, paper, food, wood, and yard waste and sweepings were found in limited sampling to contain 86 percent of total organic chlorine in the refuse, with plastics accounting for 14 percent. Total organic chlorine in this MSW amounted to 0.17 percent by weight [56]. Others have also estimated PVC contribution to organic chlorine content in U.S. MSW to be <0.2 percent [57].
Other chlorinated aliphatics form hexachlorobenzene (HCB) under certain conditions, which could produce the precursor chlorobenzene. Carbon tetrachloride (CCI4) and hydrogen gas (H2) have been combined in a hot tube at 600-650°C to yield 60 percent HCB [20]. Over long periods at 405°C various perchlorocarbons (C2CI4, C3Cl6 and C9C16) evidently can also form HCB [20].
Non-Chlorinated Aliphatics
Polyethylene, polystyrene, and related non-chlorinated polymers have been suggested to serve as intermediates or to form organic radicals upon thermal degradation [20], but mechanisms for these reactions have not been advanced.
M iscellanous Organ ics
Coal, wood, and other lignin-containing substances have been proposed to generate reaction contributors which may combine with chlorine to form precursors or even PCDD/PCDF. Lignin, the second most abundant natural compound, acts as a cementing agent to bind cellulose fibers together to make wood rigid [58, 59] . Lignin is comprised of polymeric hydroxy and methoxy subsstituted phenylpropanes [59]. Lignin has been shown to yield a variety of cresols, catechols, phenols, and other hydroxy-substituted benzene compounds when heated [20] .
Coal
109 different organic compounds including various non-· chlorinated furans and numerous polycyclic aromatic hydrocarbons (PAH) , have been detected from the emissions of several coal-fired utilities in recent years [60]. Sampling of fly ash from a coal-fired facility discovered chlorobenzenes but no PCDD at the ppb level [40 ]. Some researchers have reported a variety of chlorinated dioxins in the fly ash from a coal-and-oil co-fired power plant [61 ] , but these results have not yet been fully accepted
by EPA and others [14,62].
Wood
The combustion of wood generates a variety of organics, including phenols and P AH. Chlorobenzenes also result probably because treated wood (containing chlorophenol-based preservatives) has often been used in experiments to date. A "modern open fire" was found to generate 40 ug of chlorobenzenes/kg of aged wood and 50-1600 ug of tetra- and 4200 ug of pentachlorophenols/ kg of green wood [34]. A pre-kiln burner generated 2 ug chlorobenzene and 500 ug chlorophenol/kg of wood [34] . In other work, a pilot-scale incinerator produced chlorobenzenes from the combustion of concentrated bleach pulping (lignin-rich) residue said to contain only inorganic chlorides [34] .
Combustion of new pentachlorophenol-treated wood in a fluidized bed oven produced no increased of PCDD/ PCDF compared to similarly heated 60 year-old treated wood [63].
It has been speculated that PCDD and/or PCDF might be produced from the burning of wood alone. PCDD/PCDF has been proposed to be formed during forest fires [20 ] , and up to 0.4 ppb TCDD, 3 ppb HxCDD, 16 ppb HpCDD, and 25 ppb OCDD have been reported from home fire place soot [61]. These latter results have been criticized, however [62]. Based on results from the burning of lignosulfonate pulp waste in the presence of HCI or PVC at temperatures >590°C, the combination of lignin or a lignin-like structure and some chlorine donor (e.g., HCl) under sufficient heat has been proposed to contribute largely towards PCDD/PCDF formation [63].
Inorganic Sources of Chlorine
Gaseous chlorine (CI2), hydrochloric acid (HCI), and sodium chloride (NaCl) have been suggested to substitute to precursors to form PCDD. When each of these inorganic chlorine compounds were combusted with bituminous coal under air, C1 2 was found most able of the three species to provide chlorine towards PCDD precursor reactions [20]. HCl appeared to donate chlorine half as well as C1 2 towards PCDD/PCDF formation, while NaCI ap-
peared not to contributed any chlorine, as observed elsewhere [56].
Chlorine gas has been observed to combine with other additives to degrade monochlorobenzene to various chlorinated biphenyls [20] .
EMISSIONS OF PCDD AND PCDF
Date characterizing emissions of PCDD and PCDF have been compiled from various sampling programs conducted at American and European municipal solid waste combustion facilities. Reported test results were screened to develop an emissions data base from which a comparative analysis could be made. The studies referenced were selected primarily for the following reasons:
(a) recently published (within past three years) with sampling program focus on PCDD and PCDF.
(b) multiple isomers of PCDD and PCDF were sampled in each study.
(c) from the literature reviewed, all facilities sampled appeared to have similar control devices; i.e., electrostatic precipitators.
(d) facilities utilized similar combustion technologies, i.e., mass-b urn .
In general, U.S. EPA investigations focused on evaluating TCDD emissions with particular emphasis on the 2,3,7,8 isomer. European investigators, on the other hand, have evaluated emissions for all PCDD and PCDF compounds.
Emissions data from European and American testing programs have been condensed and provided in Table 3 in ug of PCDD/PCDF isomer per metric ton of refuse burned. These units are typical of emission factors and enable a comparison of data obtained from different facilities. A listing of these data for each detected isomer and for total PCDD/PCDF compounds is shown.
Data from domestic and European studies show a wide variation in the amounts and types of PCDD and PCDF compounds emitted. From the data presented, test results from the American studies appear to be consistently lower than the European data, as much as an order of magnitude lower for TCDD and total PCDD, although U.S. TCDF ievels are only two thirds that of the calculated European mean emission rate, and U.S. PCDF levels are half of Europe's [6,12,13,16].
352
Apparent discrepancies between domestic and European data on PCDD and PCDF compounds are not surprising because of differences in operational procedures and equipment, feed-stock composition, sampling techniques and analytical protocols, and standards for quantification. Sampling techniques used by U.S. investigators were identical, while European investigators have used a variety of sampling techniques which are poorly documented.
Recent work performed by major European investigators included the collection and analysis of flue gas and associated particulates.
Emissions data for PCDD and PCDF are typically reported by U.S. researchers in terms of nanograms per dry standard cubic meter (at 20°C) corrected to 12 percent CO2 , while European data is usually reported in terms of nanograms per normal cubic meter (at O°C). The two data sets can be better compared by standardization of temperature, excess air, and moisture. Temperature differences are easily overcome by a simple conversion factor, but to present data at 12 percent CO2 (standardized excess air) on a dry basis requires knowledge of actual CO2 and moisture content, information not generally reported by European researchers. The lack of such source data from abroad hinders its comparison with U.s. data for PCDD/PCDF emissions.
.
HEALTH EFFECTS
As mentioned previously, 2,3,7,8-TCDD has been found to be the most toxic of the PCDD and PCDF isomers. Toxicity of the other 209 isomers has been linked to the position and the number of chlorine atom substituted on the dibenzo-p-dioxin or dibenzofuran structure·. The most toxic isomers are those containing chlorine atoms in at least three of the four lateral positions (2.3,7,8) and which have at least one additional position unsubstituted; thus, OCDD is comparatively inactive [67, 68] .
TOXICITY OF PCDD AND PCDF IN ANIMALS
The toxicity of PCDD and PCDF varies widely with isomer tested and the animal species exposed. The most
TABLE 3 PCDD AND PCDF EMISSIONS INCINERATORS IN EUROPE AND THE U.S. (ug/t MSW)
Compound
TrCDD
TCDD
PnCDD
HxCDD
HpCDD
OCDD
PCDD
TrCDF
TCDF
PnCDF
HxCDF
HpCDF
OCDF
PCDF
[66J
NR
610
2418
3263
3366
1899
11556
NR
1562
2704
4786
2614
581
12247
•
[65J -
-
-
-
-
-
2563
-
-
-
-
-
-
4159
E urope 6
NR
250
467
642
581
704
2644
NR
700
743
804
880
590
3717
353
10
NR
175
451
766
766
175
2333
NR
260
541
906
640
80
2427
L64
NR
26
72
164
158
323
743
NR
146
179
123
82
54
584
Mean
-
266
853
1209
1218
776
4322
-
667
1042
1655
1054
326
4744
u.s. [13J
65
32 -
82
37
13 229
1529
446 -
306
37
3
2321
common measure of acute toxicity in animal species is the LDso, the dosage lethal to 50 percent of a laboratory population. The lower the LDso, the more toxic the compound to that particular species. For 2,3,7 ,8-TCDD alone, values range over 5,000-fold from an LDso of 0.6 ug/kg body weight in guinea pigs [69] to 1,157 to 5,051 ug/kg body weight in hamsters [70, 71] . Comparing the toxicity of different PCDD isomers within the most sensitive animal species, guinea pigs, it is found that LDso s are 300,000 ug/kg for 2,8-DCDD, 72.5 ug/kg for 1,2,3,4,7,8-HxCDD, and 600-7,180 ug/kg for 1,2,3,4,6,7,8-HpCDD [69] .
Other factors which may affect toxicity include mode of exposure i.e., inhalation, ingestion or application to the skin and whether the compound is dissolved in a solvent or adsorbed to a solid particle. In rats, attachment of TCDD to soil particles was found to reduce its absorption after oral administration by half and, when attached to activated carbon, absorption was almost completely prevented [72]. Other researchers have found matrix effects in rabbits [73, 74] and in rats [75] .
The most well-known effect of PCDD/PCDF exposure is the development of chloracne, a skin ailment similar to acne vulgariS. This effect has been observed in humans, rhesus monkeys [69], rabbits, and hairless mice [77] , but not in guinea pigs, hamsters, rats or other mice. Pathological effects to the immune system, liver, urinary tract and gastric mucosa have also been noted in various test animals. TCDD has also been demonstrated to be fetotoxic, embryotoxic and teratogenic; and in rats and mice to be carcinogenic [78-81 ] .
TOXICITY OF PCDD AND PCDFS IN HUMANS
In addition to chloracne, liver dysfunction, and disorders of fat and carbohydrate metabolism and of the cardiovascular, urinary, respiratory and pancreatic systems have been reported. Neuropsychiatric disorders may also develop.
The evidence for TCDD carinogenicity in humans is still equivocal, although support seems to be increasing for the correlation of TCDD exposure and the development of soft tissue sarcomas [82] . Uncertainty exists because exposure has generally been to chemicals (e.g., chlorophenols and their derivatives) contaminated with TCDD as impurities. This mixed exposure makes it difficult to definitively show that TCDD alone is a human carcinogen. The potential carcinogenicity of PC OF has not been studied to date.
EXISTING EXPOSURE STANDARDS
A variety of government agencies, in Canada, the Netherlands and in the U.S. have established exposure
standards for PCDD and PCDF, although primarily for 2,3,7,8-TCDD. These exposure limits appear to range widely in concentration, although all were developed from a similar data base.
Most relevant to this discussion is the U.S. Environmental Protection Agencies' 1981 "Interim Evaluation of Health Risks Associated with Emissions of TCDD from Resource Recovery Facilities" [11]. Based on emission data from five domestic refuse combusting facilities, this document concluded that up to 3.8 X 10-8 ug/m3 of 2,3,7,8-TCDD and up to 9.2 X 10-8 ug/m3 of total TCDD would not represent a health hazard. This conclusion was based upon quantitative carcinogenic risk assessments using a series of mathematical models.
The New York State Department of Environmental Conservation subsequently adopted the EPA's level for total TCDD as an acceptable ambient level from a point source in their Air Guide No. 1 document [83] .
•
The Ontario Ministry of Labour, Ontario, Canada [84] and the government of The Netherlands [82] have both established guidelines for acceptable air levels of 2,3,7 -8-TCDD. Both of these guidelines are based on levels that were found to have no adverse effects in animal testing with a safety factor added in to account for animal-human differences. The Netherlands' standard is based upon an acceptable daily intake of 1 nanogram (ng)/kg/day of 2,3,7,8-TCDD (the no adverse-effect level reported by Kociba, et al. [80] ; Murray, et al. [85]); which reduces to 4 picogram (pg)/kg/day when a 250-fold safety factor is applied. Assuming a 60 kg person breathing 20m3 per day, an acceptable ambient level of 1.2 X 10-5 ug/m3 can be calculated based on the Netherlands Standard.
The Ontario Ministry of Labour also used the 1 ng/kg/ day no-effect-Ievel, but included a lower safety factor of 100. Assuming the same 60 kg person breathing 20 m3 per day, they arrived at a recommended air standard of 3.0 X 10-5 ug/m3.
CONCLUSIONS
Based on the information presented herein, the following conclusions are made.
1. Much research has been conducted or is underway on sources of PCDD/PCDF in the environment, but many unknowns exist, especially as concerns large-scale solid waste combustion units. Precursor content of MSW needs to be further investigated because of the relative ease with which precursors can convert to or volatilize PCDD/PCDF at temperatures typical of resource recovery facilities. More research into mechanisms for de novo synthesis of PCDD/PCDF from chlorinated aliphatic and nonchlorinated aromatic compounds would also be helpful, but it is
354
very difficult to correlate laboratory reaction analyses to PCDD/PCDF formation in incinerators of heterogeneous refuse. More useful information will be obtained from a determination of chlorine content in MSW components from which reactive chlorine is formed. Since synthetic and natural aromatic compounds are abundant in MSW, chlorine presence becomes the rate limiting factor for PCDD/PCDF formation via the de novo theory. The most significant contributors of reactive chlorine have not yet been defined.
2. It has been suggested that the removal of PVC, an obvious organic chlorine-containing component in waste, could limit HCl formation. Other sources of organic chlorine in MSW (e.g., paper, textiles) exist, so implementing PVC source separation or other removal programs would be premature until the nature of other possible chlorine donors for HCl formation in MSW is investigated further. In addition, the role of inorganic chlorine conversion to HCl remains to be determined; indications to date. are that it plays a very minor role.
3. Investigation of the role of lignin decomposition to provide essentially nonchlorinated precursors in important because of its ubiquitous presence in newsprint, cardboard, rough wood, and food and yard waste in MSW.
4 . An analysis of representative emission data indicates that PCDF and PCDD emissions from European resource recovery facilities are 2 and 10 times, respectively, those of U.S. facilities. However, until source data for European facilities becomes available, strict comparison with U.S. plants is not advisable.
5. A comparison of existing air quality standards shows a wide range of concentrations that are considered adequate to protect the public health. It is interesting to note that these range of levels are all based on a similar toxicological data based. The extensive research underway in PCDD/PCDF health effects should be correlated to ambient predictions and risk assessments developed for all PCDD and PCDF isomers, not just 2,3,7 ,8-TCDD, as is presently the case in the U.S.
ACKNOWLEDGMENT
The work presented in this paper was supported in part by the Port Authority of New York and New Jersey. Special thanks are extended to Paul Giordano and Frances Topping of CDM for staff support.
REFERENCES
[1) Esposito, et ai., (EPA) 1980, Dioxins, EPA 600/2-80-197,351 pp.
(2) Cavallaro, A., et al., 1982, "Summary of Results of PCDD Analysis from Incinerator Effluents," Chemosphere 11(9): 859-868.
355
(3) Rappe, H. R., 1983, "Chlorinated Dioxins in the Environment," Environmental Science and Technology 17(3): 124A-128A.
(4) Olie, K., P. 1. Vermeulen, and O. Hutzinger, 1977, "Chlorodibenzo-p-dioxins and Chlorodibenzofurans are Trace Components of Fly Ash and Flue Gas of Some Municipal Incinerators in The Netherlands," Chemosphere 6(6):455460.
(5) Lustenhouwer, J. W. A., K. Olie, and O. Hutzinger, 1980, "Chlorinated Dibenzo-p-Dioxins in Incinerator Effluents: Review of Measurements and Mechanisms of Formation," Chemosphere 9:501-522.
(6) Gizzi, F., et al., 1982, "PCDD and PCDF in Emissions from an Urban Incinerator, 1. Average and Peak Valves," Chemosphere 11(6):577-583.
(7) Hutzinger, et al., 1981, "PCDD and PCDF: A Bioanalytical Approach," Chemosphere 10:19.
(8) Buser, H. R., et al., 1978, "Identification of Polychlorinated Dibenzofuran Isomers in Fly Ash and PCB Pyrolysis," Chemosphere 5:419429.
(9) Eiceman, G. A., R. E. Clement, and F. W. Karasek, 1979, "Analysis of Fly Ash from Municipal Incinerators for Trace Organic Compounds," Analytical Chemistry 51:2343-2350.
[lO) Arthur D. Little, Inc., 1981, Study on State-of the-Art of Dioxin Combustion Sources, ASME, N.Y., NY, 160 pp.
(11) EPA, November 1981, Interim Evaluation of Health Risks Associated with Emissions of TCDDs from Municipal Waste Resource Re covery Facilities, Office of the Deputy Administrator.
(12) Barnes, D. G. (EPA), 1982, "Assessing TCDD Emissions from Municipal Waste Combustors," Presented at the 3rd International Symposium on Chlorinated Dioxins and Related Compounds, Salzburg, Austria, October 12-14.
(13) Redford, D. P., C. 1. Haile, and R. M. Lucas, (EPA) 1981, "Emission of PCDD from Combustion Sources," International Symposium on Chlorinated Dioxins and Related Compounds, Arlington, VA, October 24-29.
(14) National Research Council of Canada, Ottawa, 1981, PCDD: Criteria for their Effects on Man and His Environment, Publication No. NRCC 18574, ISSN 0316-0114, 251 pp.
(15) Lamparski, 1. 1. and T. J. Nestrick, 1980, "Determination of Tetra-, Hexa-, Hepta-, and Octochlorodibenzo-p-Dioxin Isomers in Particulate Samples at Parts Per Trillion Levels," Analytical Chemistry 52:2045-2054.
(16) O'Connell, W. L., G. C. Stotler, and R. Clark, 1982, "Emissions and Emission Control in Modern Municipal Incinerators," 19th National Waste Processing Conference, ASME, N.Y., NY.
[17) Hutzinger, 0., S. Safe and V. Zitko, 1974, The Chemistry of PCBs, CRC Press, Cleveland, OH.
(18) Nilsson, C. A., et al., 1978, in Pentachlorophenol: Chemistry, Pharmacology, and Environmental Toxicology, K. R. Rao, Ed., Environmental Science Research Series, Volume 11, Plenum Press, N.Y., NY.
[ l 9) Yamagishi, T., et ai., 1981, "Polychlorinated Dibenzo-pDioxins and Dibenzofurans in Commercial Diphenyl Ether Herbicides, and in Fresh Water Fish Collected from the Application Area," Chemosphere 10(10):1137-1144.
(20) Choudhry, G. G., K. Olie, and O. Hutzinger, 1982, "Mechanisms in the Chlorinated Compounds Including PCDD," in Chlorinated Dioxins and Related Compounds, Impact on the Environment, O. Hutzinger, et al., Eds., Pergamon Press, N.Y., NY, pp. 275-301.
(21) Nilsson, C. A., et ai., 1974, "Chromatographic Evidence for the Formation of Chlorodioxins from Chloro-2-Phenoxyphenols," Journal of Chromatography 96 :137-147.
(22) Liberti, A., and D. Brocco , 1 982, "Formation of PCDD and PCDF in Urban Incinerator Emissions," in Chlorin ated Diox· ins an d Related Compounds, Impact on the Environment, Hutzinger, et al., Eds., Pergamon Press, N .Y., NY, pp. 245-25 2.
( 23 ) Bosco , B . , F. Vastola, and F. Donato, 1 982, "The Solid Waste Disposal Problem in Southern Italy : The Lecce, Cosenza, and Lamezia Terme Plants," 10th National Waste Processin g Conference, ASME, N.Y., NY, pp. 231-254.
(24 ) Niessen, W. R., 1977, "Properties of Waste Materials," in Handbook of So lid Waste Man agement, D. G. Wilson, Ed ., Von Nostrand Reinhold Co., N .Y. , NY, pp. 1 0-60.
(25 ) Federal Register, May 3 1 , 1 979. (26) Firestone, D., et ai., 1972, "Determination of Poly
chlorodibenzo-p-Dioxins and Related Compounds in Commercial Chlorophenols," Journal of the Society of Analytical Chemistry 55(1) :85 -92 .
(27 ) Woolson, E. A., R. F. Thomas, and P. D. J. Ensor, 1972, Survey of Polychlorodibenzo-p-Dioxin Content in Selected Pesticides 20(2) :350-354.
(28 ) Advisory Committee on Pesticides, 1980, Fu rther Review of the Safety for Use in the U.K. of the Herbicide 2, 4, 5,-T, Pesticides Branch, Ministry of Agriculture, Fisheries and Food, London, England.
(29 ) Rappe, C. R. , et ai., 1978, "Formation of PCDD and PCDF by Burning or Heating Chlorophenolates," Ch emosphere 7 :257-268 .
[30) Buser, H . R. and H. P. Bosshardt, 1976, "Determination of PCDD and PCDP in Commercial Pentachlorophenols by Combined GC-MS," Journal of the Soc iety of An alytical Chemistry 59 :562-569.
( 3 1 ) Villaneuva , E . C. , R . W. Jennings and V. W. Burse , 1973, "Chlorodibenzo-p-Dioxin Contamination of Two Commercially Available Pentachlorophenols," Journal of Agricultural Food Chemistry 21(4) :739.
( 32 ) Rappe, et al., 1979, Chemosphere 8 :259. ( 3 3 ) Buser, H . R. , 1975 , "PCDD: Separation and Identifica
tion of Isomers by GC/MS," Journal of Chromatography 1 14 :95 . ( 3 4 ) Ahling and Lindskog, 1982, "Emission of Chlorinated
Organic Substances from Combustion," in Chlorin ated Dioxins an d Related Compounds, Impact on the En vironment, O. Hutzinger et al . , Eds., Pergamon Press, N .Y., NY, pp. 215-226 .
( 3 5 ) Buser, H. R. , 1979, "Formation of PCDFs and PCDDs from the Pyrolysis of Chlorobenzenes," Chemosphere 8(6) :415-424.
(36 ) California Air Resources Board (ARB), March 25 , 198 1 , "A Proposed ARB Policy Regarding Incineration as an Acceptable Technology for PCB Disposal," Sacramento , California.
( 3 7 ) Federal Register, May 1 9 , 1 980. ( 3 8 ) EPA, February 1 98 1 , Incineration of PCBs. Summary of
A pproved Actions for Rollins Environmental Services, Deer Park, Texas, and En ergy Systems Company (ENSCO), El Dorado, A rkansas, EPA Region VI, Dallas, Texas.
( 39 ) TRW, Inc., September 1 982, An Assessment of the A bility of the MIT Vu lcanus to Inc in erate Wastes Contain ing PCBs, revised draft, Contract No. 6 8-02-3 174, Industrial Environmental Research Laboratory , EPA , Cincinnati, OH.
[40) Iunk, G. A. and I. I. Richard, 1 98 1 , "Dioxins Not Detected in Effluents from Coal/Refuse Combustion," Chemosphere 10 :237 -241 .
(41 ) Buser, H. R. and C. Rappe, 1 979 , "Formation of PCDFs from the Pyrolysis of Individual PCB Isomers," Chemosphere 8(3) : 157 .
(42) Ahling , B . , 1978, Destruction of Ch lorin ated Hydrocarbons in a Cement Kiln , Report of the Swedish Water and Air
356
Pollution Research Institute, Stockholm. (43 ) Stehl, R. M . , and 1. 1. Lampaski, 1 97 7 , "Combustion
of Several 2,4 ,5-Trichlorophenoxy Compounds: Formation of 2,3 ,7 ,8-TCDD," Science 1 97 : 1008-1009 .
(44 ) Ahling, B. , et al., 1 977 , "Formation of PCDD and PCDF During Combustion of a 2 ,4 ,5-T Formulation," Chemosphere 6 :46 1468.
(45 ) Lindahl, R. , C. Rappe, and H. R . Buser, 1980, "Formation of PCDD by Pyrolysis of Polychlorinated Diphenyl Ethers," Chemosphere 9(5/6) :35 1 .
(46 ) Nestrick, T. I., 1. 1. LamparSki, and D. I . Townsend, 1 980, "Identification of TCDD Isomers at the 1 -ng Level by Photolytic Degradation and Pattern Recognition Techniques," Analytical Chemistry 5 2 : 1 865-1874.
(47 ) Prof. Edward Boettner, University of Michigan (retired), for EPA, 1968-69 , personal communication.
(48) Kaiser, E. R. , and A. A. Carotti, 1972, "Municipal Incineration of Refuse with 2% and 4% Addition of Four Plastics: Polyethylene, Polyurethane, Polystyrene, and Polyvinly Chloride," 1972 National Waste Processin g Conference, ASME, N.Y., NY.
(49 ) Oda, T., K. Chiba, and H. Hosokawa, 1975 , "Thermal Decomposition of Plastic Waste Containing Polyvinyl Chloride," 1 st International Conference on Conversion of Waste-to-Energy , Montreaux, Switzerland, November 3-5 , 1975 , IEEE Catalog, Number 75CH1 008-2CRE.
[50) Tsutsumi, S . , 1975 , "Thermal and Steam Cracking of Waste Plastics," ibid.
[ 5 1 ) Alter, H . , and I . I . Dunn, Ir., 1980, "Recovery of Materials from Waste in Europe," in Solid Waste Conversion to Energy: Current European and U.S. Practice, Marcel Dekker, Inc. Publishers, N.Y . , NY, pp. 32-5 7 .
[ 5 2 ) Camp Dresser & McKee Inc., 1983 , An Overview of Chlorinated Dibenzo-p-Dioxin an d DibenzoJuran Compoun ds Relative to the Essex County Resource Recovery Facility, prepared for the Port Authority of New York and New Iersey, N.Y., NY, 90 pp.
[ 53 ) Society of the Plastics Industry Statistics, N.Y., NY, 1983.
[54 ) Buekens, A. G. , 1977, "Some Observations on the Recycling of Plastics and Rubber," Conserv ation and Recyclin g 1(3/4) :247-271 .
[ 5 5 ) Boehmlaender, F . , 1 97 1 , "Waste Gases from Refuse Incineration," Staub-Reinhaltun g der Luft 3 1 (5), May, p. 32.
[ 56 ) Hollander, et ai., 1 980, "A Comprehensive Municipal ·Refuse Characterization Program," 9th National Waste Processin g Conference , ASME, N .Y., NY, pp. 221-237 .
[ 57 ) Alter, H. , U.S. Chamber of Commerce, Washington, D. C . , October 1 9 8 3 , personal communication.
[ 5 8 ) Crawford, D. 1., and R. 1. Crawford, 1980, "Microbial Degradation of Lignin," Journ al of applied Polymer Science 17 :3567-3576.
[ 5 9 ) Goheen, D. W., D. 1. Glennie, and C. Y. Hoyt, 1967, "Lignin," in Encyclopedia of Chemical Technology , Volume 12 , Interscience Publishers, N.Y., NY, pp. 361-3 8 1 .
[60) TRW, Inc., 1980, POM Emissions from Stationary Conventional Combustion Processes with Emphasis on PCCD, PCB, an d PCDF, prepared for EPA, Industrial Environmental Re learch Laboratory , Research Triangle Park, NC, 1 1 7 pp.
( 6 1 ) Crummett, W. B. , 1982, "Environmental Chlorinated Dioxins from Combustion - The Trace Chemistries of Fire Hypothesis," Chlorin ated Dioxins in the Environment, Impact on the Environment, Pergamon Press, N.Y., NY, pp. 253-274.
(62) Various, Science 213 : 1059 (1981). (63 ) Olie, K., Van den Berg, and O. Hutzinger, in press,
"Formation and Fate of PCDD and PCDF from Combustion Processes," to be published in Ch emosphere.
(64 ) Swiss Federal Office for Environmental Protection, Zurich, 1982, "Environmental Pollution Due to Dioxins and Furans from Communal Rubbish Incineration Plants," Schriften reihe Umneltschutz , No. 5 .
(65) Benfenati, et ai. (unpublished draft), 1983, Emissions [rom the Stack an d Combustion Con ditions, Mario Negri Institute for Pharmcological Research, Milan, Italy.
(66) Olie, K., J . W. A. Lustenhouwer, and O. Hutzinger, 1982, "PCDD and Related Compounds in Incinerator Effluents," Chlorinated Dioxins and Related Compounds, Impact on the En vironment, O. Hutzinger et aI., Eds., Pergamon Press, N.Y., NY, pp. 227-244.
(67) Huff, J. E., et aI., 1980, "Long Term Hazards of Polychlorinated Dibenzodioxins and Polychlorinated Dibenzofurans," Environmental Health Perspectives 36:221-240.
(68) Kende , A. S. , and Wade, J . J., 1973, "Synthesis of New Steric and Electronic Analogs of 2 ,3 ,7 ,8-Tetrachlorinated Dibenzop-Dioxin," Environ mental Health Perspectives 5 :49-59 .
(69) McConnell, E. E., et al., 1978, "The Comparative Toxicity of Chlorinated Dibenzo-p-Dioxin in Mice, Guinea Pigs," Toxi-cology an d Applied Pharmacology 44 : 335-356.
.
(70) Olson, J. R. , Holscher, M. A., and Neal, R. A., 1980, "Toxicity of 2 ,3 ,7 ,8-TCDD in the Golden Syrian Hamster," Toxicology an d Applied Pharmacology 55 :67-78.
( 7 1 ) Henck , J . W., 1981 , "2,3,7 ,8-TCDD: Acute Oral Toxicity in Hamsters," Toxicology an d Applied Pharmacology 54 :405-407.
(72) Poiger, H. , and Schlatter, C. , 1980, "Influence of Solvents and Absorbents on Dermal and Intestinal Absorption of TCDD ," Food an d Cosmetics Toxicology 1 8 :477 -48 l .
( 7 3 ) Silkworth, J . , et aI., 1982, "Acute Toxicity in Guinea Pigs and Rabbits of Soot from a Polychlorinated Biphenyl-Containing Transformer Fire," Toxicology and Applied Pharmacology 65 :425439.
(74) Bonaccorsi, A., et al., 1 983 , "The Influence of Soil Particle Adsorption on TCDD Biological Uptake in the Rabbit,"
Chemosphere, in press. (75 ) Van den Berg, M. , Olie, K., and Hutzinger, 0., 1983,
"Uptake and Selective Retention in Rats of Orally Administered Chlorinated Dioxins and Dibenzofurans from Fly Ash and Fly Ash Extract," Chemosphere, in press.
( 76 ) McConnell, E. E. , J. A. Moore, and D. W. Dalgard , 1978, Toxicity of 2 ,3 ,7 ,8-TCDD in Rhesus Monkeys (Jrfacaca mulatta) Following Single Oral Dose," Toxicology an d Applied Pharmacology , 43 : 1 75-189.
( 7 7 ) Inagami, K. , et aI., 1 969 , "Experimental Studies of Hairless Mice Following Administration of Rice Oil Used by Yusho Patients," Fu ku oka Acta. Med. 60:548-553 (in Japanese).
( 78 ) National Toxicology Program, 1982, Carcinogenic ity Bioassay of 2,3, 7,8-TCDD in Osborn e-Mendel Rats an d B6CF1 Mice, Gavage Stu dy , NTP-80-3 1 , NIH Publication No. 82-1765.
( 79 ) Van Miller, 1. P., 1. J. Lalich, and J. R. Allen, 1 977 , "Increased Incidence of Neoplasms in Rats Exposed to Low Levels of 2 ,? ,7 ,8-TCDD," Chemosphere 9:537-544.
( 80 ) Kociba, R. J . , et al., 1978, "Results of a Two-Year Chronic Toxicity and Oncogenicity Study of 2 ,3,7 ,8-TCDD in Rats," Toxicology an d Applied Pharmacology 46 : 279-304.
( 8 1 ) Toth, K., et al., 1979, "Carcinogenicity Testing of Herbicide 2 ,4 ,5-T Ethanol Containing Dioxin and of Pure Dioxin in Swiss Mice," Nature 278:548-549 .
( 82 ) Barnes, D . G., 1 983 , "Dioxin Production from Combustion of Biomass and Wastes," presented at En ergy from Biomass and Wastes VII, Institute of Gas Technology Symposium, Lake Bueno Vista, Florida, January 24-26 , 1983 , 37 pp.
( 83 ) New York State Department of Environmental Conservation, 1982, Air Guide - 1 . Application of 6 NYC RR Part 212 - Toxic Air Contaminants, 37 pp.
( 84 ) Harding, D. H. , 1982, "Chlorinated Dioxins and Chlorinated Dibenzofurans," Ambient Air Guidelin e , Health Studies Service Ministry of Labour, Ottawa, Canada, 26 pp.
( 85 ) Murray, F . J . , et al., 1979, "Three Generation Reproductive Study of Rat Liver and 2 ,3 ,7 ,8-TCDD in the Diet," Toxicology and Applied Pharmacology 50:24 1-252.
357