product specification sheet multi-stream reid vapor pressure analyzer auto validation ... · 2018....

2
Multi-Stream Reid Vapor Pressure Analyzer Auto Validation System PRODUCT SPECIFICATION SHEET Our People, Your Solution Xenon, Inc. is a full-service engineering, integration, and field service solutions provider for your Process and Environmental Analytics, Industrial Instrumentation & Automation, and Electrical System needs. Patent Pending www.xenoninc.com • 866.571.8595

Upload: others

Post on 28-Feb-2021

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PrODuCt SPeCIFICatION SHeet Multi-Stream Reid Vapor Pressure Analyzer Auto Validation ... · 2018. 2. 7. · Reid Vapor Pressure Analyzer Auto Validation System PrODuCt SPeCIFICatION

Multi-StreamReid Vapor Pressure Analyzer

Auto Validation System

PrODuCt SPeCIFICatION SHeet

Our People, Your SolutionXenon, Inc. is a full-service engineering, integration, and fi eld service solutions provider for your Process and environmental analytics, Industrial Instrumentation & automation, and electrical System needs.

Patent Pending

www.xenoninc.com • 866.571.8595

Page 2: PrODuCt SPeCIFICatION SHeet Multi-Stream Reid Vapor Pressure Analyzer Auto Validation ... · 2018. 2. 7. · Reid Vapor Pressure Analyzer Auto Validation System PrODuCt SPeCIFICatION

SyStem FeatureS• Fully automated system with PLC/HmI control and

health monitoring to ensure reliable and repeatable sample analysis

• remote (DCS) and local (HmI) system operation, including stream selection, system status and alarms

• Scalable to operate multiple streams to single or multiple analyzers

• Scalable to validate with multiple reference samples to multiple analyzers simultaneously or sequentially

• Stream selection (process and validation) fully independent for each analyzer

• Double-Block and Bleed Valves to eliminate cross-interference between process streams and validation samples

• Validate with gasoline reference and/or other known reference samples e.g. Neohexane

• Pressure monitoring on each reference cylinder ensures consistent sample delivery to each analyzer. the system will not initiate a validation cycle if pressures are not within operator-defined tolerance

• Dynamic pressure/flow control to each analyzer assures integrity of analysis. Flow, pressure and temperature is monitored by the PLC for monitoring and alarming

• auto regeneration of gasoline reference value upon refill of gasoline reference cylinder

• upon power failure, system defaults to process stream and isolates validation samples avoiding disruption to blend operations

• efficient design to minimize internal volume, residence time and sample waste

• real-time data acquisition and historical data analysis

• View or control system over LaN/internet via customizable web interface

• FtP Server for remote data download (data encryption also available)

• multi-user security access

Xenon Inc. Headquarters2146 michelson Drive, Suite B, Irvine, Ca 92612P: 866.571.8595 • F: 866-281-3044 • www.xenoninc.com

Xenon Inc. Gulf operatIonsOne riverway, Suite 1700 Houston, tX 77056

process and environmental analytic services Inquiries:[email protected]

Instrumentation, automation, and electrical engineering services Inquiries: [email protected]

product Inquiries: [email protected]

national field service partner: triad Control Systems

West coast sales & service preferred systems Integrator:aBB, Phoenix Contact, triconex, Invensys Wonderware

teCHNICaL SPeCIFICatIONS

electrical supply• all components rated Class 1, Div 2, Grp. C, D• Power Consumption: 60 W typical*• Power Supply: • 90-260VaC; 24VDC range 18-30VDC• Interface: • analog Inputs • analog Input range: 4-20ma 24VDC, 0-10VDC • analog Outputs: • analog Output range: 0-20 ma • Digital Inputs: • (8) 24VDC

• Digital Outputs: • (11) Isolated 5a • (8) Non-Isolated (5a) • relay Outputs: Single-pole/Double throw (SPDt) • alarming: • Configurable • Serial mODBuS • mODBuS tCP/IP • Operating temperature: -0°C to 50°C

Instrument air/nitrogen supply• Clean and Dry• Pressure: 60 PSIG (Nominal); 80 PSIG (max)

drain (optional)• For stream select valve vent

*exact specifications based on customer configuration

Patent Pending

Gasoline Reference Valve and Control Enclosure

RVP Validation System

Stream Select Valve Panel