product manual rev. (11/06) - sweets · citadel architectural products, inc. 3131-a north franklin...
TRANSCRIPT
©2
00
3 C
itad
el A
rch
itect
ura
l Pro
du
cts,
In
c.
An
IS
O 9
00
1:2
00
0 R
eg
iste
red
Co
mp
an
y.S
ino
Co
re® is
a r
eg
iste
red
tra
de
ma
rk o
f C
itad
el A
rch
itect
ura
l Pro
du
cts,
In
c.P
rin
ted
In
Th
e U
.S.A
. F
orm
# 7
.02
.MA
.A
Re
v. (
06
/03
) S
up
ers
ed
es
(12
/98
)
PRODUCT MANUAL
Citadel Architectural Products, Inc. • An ISO 9001:2000 Registered Company • 3131-A North Franklin RoadIndianapolis, Indiana 46226 • phone (800) 446-8828 • fax (317) 894-6333 • www.citadelap.com • [email protected]
Rev. (11/06)
Table Of ContentsPRODUCT DATA SHEET
INSTALLATION GUIDELINES
TYPICAL DETAILS
GUIDE SPECIFICATION
STANDARD WARRANTY
Panel & System Description
Installation Overview
Pre-Installation Guidelines
General Work
Maintenance Of The Panel FinishWork SequenceTrim MoldingsRecommended Tooling & EquipmentInstallation Accessories
IsometricMolding DetailsSection DetailsIntersection Details
Basic Uses & ApplicationsComposition & MaterialsPanel Weight & ThicknessMaterial TolerancesSizes AvailableGeneral Limitations
Material Receiving & InventoryTransporting & HandlingStoring The Material UnitsScheduling & Grid Layout
Limitations Of The Panel SystemFabrication Of The PanelsCutting & Fitting MoldingsProper Sealant ApplicationProper Adhesive ApplicationFastening The Panels & MoldingsThe Protective Film
Citadel Architectural Products, Inc.3131-A North Franklin RoadIndianapolis, Indiana 46226phone: (317) 894-9400
(800) 446-8828fax: (317) 894-6333
(800) [email protected]
CUSTOMER SERVICE &TECHNICAL ASSISTANCE Call (800) 446-8828 or visit
www.citadelap.com for downloads!...
SAMPLES & LITERATURE:Product or color samples, as well as additional literature may beobtained by contacting our sample department.
BINDER ON CD:Our complete binder is available on CD in an easy-to-use .pdfformat. Also included are Guide Specifications in MicroSoft® Word®
(.doc) and NotePad (.txt) formats as well as Typical Details inAutoCAD® drawing format (.dwg).
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com PRODUCT DATA SHEET
©2
00
5 C
ita
de
l A
rch
ite
ctu
ral
Pro
du
cts,
In
c.
An
IS
O 9
00
1:2
00
0 R
eg
iste
red
Co
mp
an
y.S
ino
Co
re® is
a r
eg
iste
red
tra
de
ma
rk o
f C
itad
el A
rch
itect
ura
l Pro
du
cts,
In
c.P
rin
ted
In
Th
e U
.S.A
. F
orm
# 7
.02
.PD
.B
Re
v. (
03
/05
) S
up
ers
ed
es
(06
/03
)
Product Data SheetPRODUCT NAME:SinoCore®
Prefinished Architectural Panels
MANUFACTURER:Citadel Architectural Products, Inc.3131-A North Franklin RoadIndianapolis, Indiana 46226phone: (317) 894-9400
(800) 446-8828fax: (317) 894-6333
(800) 247-2635web: www.citadelap.comemail: [email protected]
OVERVIEW:SinoCore® is a composite panelmade by laminating either textured orsmooth prefinished aluminum skinsto a core of high density polypropy-lene. A second aluminum skin isadded as a backer and providespanel balance.
Panels are furnished with astrippable film (or interleafedmicrofoam) on the painted surfacesto protect the finish during shipmentand installation.
SinoCore® is attached to the sub-strate using either mechanicalfasteners or construction adhesive,depending upon the method se-lected. Joints are finished using onepiece or two piece extruded alumi-num trim moldings.
BASIC USES & APPLICATIONS:As an alternative or complement toother exterior building finishes suchas stucco or brick, SinoCore® isdesigned for applications such as:claddings, fascias, canopies, andaccent bands.
SinoCore® is typically used on lowand medium rise buildings such asschools, banks, office parks, medicalfacilities, etc... However, with avariety of finish options, SinoCore®
also adds aesthetic interest tootherwise monolithic structures (i.e.preformed warehouse walls).
PANEL & SYSTEMDESCRIPTION
Metric (mm)
.254mm
.609mm4.00mm.254mm.609mm
Component
Prefinished Textured Aluminum Face(or) Prefinished Smooth Aluminum FaceHigh Density Polypropylene CorePrimed Smooth Aluminum Backer(or) Primed Smooth Aluminum Backer
Standard (in)
.010”
.024” (min)5/32”.010”.024”
•
••
¹ Technical Properties are based upon the Typical Composition. Selecting optional components mayalter these properties.
TABLE 1. COMPOSITION & MATERIALS¹:
FEATURES & BENEFITS:As a complete exterior cladding system, SinoCore® offers a number ofbenefits to the building owner, architect, and installer including:
• Lightweight With an innovative polypropylene core, SinoCore® is lightweight making it easier to handle, cut in-the-field, and install.
• Easy Installation Simple sheets/trim concept easy to understand. Standard carpentry knowledge and tooling is all that is required for installation.
• Curveable While tight radius requirements are not recommended with SinoCore®, panels can be gently curved in-the-field to acheive graceful lines.
• Color Matched Moldings Several different profiles available to complete the system look. Moldings are painted to color match or complement panels.
• Versatile With textured or smooth skins available, SinoCore® can provide a number of different looks for your project including metallic and anodized finishes.
• Water Resistant Virtually unaffected by water, SinoCore® provides an attractive alternative for situations where moisture is a primary concern.
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comPRODUCT DATA SHEET
3.93 kg/m²4mm
Panel Weight¹Nominal Thickness
TABLE 2. PANEL WEIGHT & THICKNESS:
0.81 lbs/ft²3/16”
MetricComponent Standard
GENERAL LIMITATIONS:SinoCore® is intended for use as alightweight exterior cladding. Itshould not be used in low gradeareas where panels are exposed tohigh traffic and/or heavy abuse. Itcannot be considered as a structuralelement of a wall assembly.
SYSTEM FINISHES:SinoCore® panels are available witheither smooth or textured prefinishedaluminum skins. Standard colors intextured skins are offered with a coilcoated polyester. Panels can alsobe ordered in premium colors with anacrylic urethane coating.
Smooth standard and metalliccolors are furnished with a Kynar500® coating. Anodized finishes areavailable as a standard finish.Custom colors are also available.
Moldings are coated using a polyes-ter, acrylic urethane or Kynar 500®
paint system depending upon thepanel finish and can be painted tomatch any standard or custom color.
MECHANICAL FASTENING:For a non-progressive installation,the two piece extruded moldings maybe used. Plastic receivers are firstinstalled, then construction adhesiveis placed in the field of the panel.The panels are then fastened aroundthe perimeter and sealant is applied.The joints are completed with asnap-on aluminum cover.
NON-MECHANICAL FASTENING:For a progressive installation, theone piece moldings are used. Theextrusions are mechanically fastenedto the substrate and the panels arethen installed using sealant at theperimeter and construction adhesivein the field of the panel.
INSTALLATIONOVERVIEW
(1219mm x 2438mm)(1219mm x 3048mm)(1219mm x 3658mm)(1524mm x 2438mm)(1524mm x 3048mm)(1524mm x 3658mm)
48” x 96”48” x 120”48” x 144”60” x 96”60” x 120”60” x 144”
Cut-to-size panels are also available invirtually any size up to 60” x 144”.
SIZES AVAILABLE:Thickness:Length Dim:Width Dim:Squareness:
SinoCore® is supplied with clean,machine trimmed edges.
MATERIAL TOLERANCES:±1/32” (±0.79mm)+0, -1/8” (+0, -3.18mm)+0, -1/8” (+0, -3.18mm)1/64” (0.4mm) perlineal foot
LOAD DEFLECTION¹:
¹ Panel tested while supported on four sides.
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
De
fle
cti
on
(in
)
0
5.2
10
.4
15
.6
20
.8 26
31
.2
36
.4
41
.6
46
.8 52
57
.2
Load (psf)
4’x4’
4’x8’
PANEL FINISH SYSTEMS:
STANDARD WARRANTY:
Panel Warranty:Polyester/AcrylicFinish:
Kynar 500® Finish:
Anodized Finish:
5 Years5 YearsNo change greaterthan 6 for chalk,8 E units for fade20 YearsNo change greaterthan 8 for chalk,5 E units for fade20 Years (prorated)
Standard Textured:
Custom Textured:
Standard Smooth:
Custom Smooth:
Coil CoatedPolyesterSpray AppliedAcrylic UrethaneCoil CoatedKynar 500®
Spray AppliedKynar 500®
R-ValueFlame SpreadStiffness (EI)¹Allowable BendingMoment¹Tensile Yield¹Ultimate Tensile¹
TABLE 3. PANEL PERFORMANCE:
1.16Class A2.59E+4
2.63E+1
7.34E+3
1.04E+4
---ASTM E84ASTM E72ASTM E72
ASTM E72ASTM E72
°F ft²/BTU---lb-in²/ft widthlb-ft/ft width
lb/ft widthlb/ft width
ValueProperty Test Unit
¹ Weight and testing based upon panels using an .024” smooth face skin and an .010” smooth back skin.
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com
Installation Guidelines:One Piece & Two Piece Molding Systems
BE SURE TO READ, UNDERSTAND AND FOLLOW ALL GUIDELINES. Manufacturer guidelines may vary dependingupon specific application and project conditions. The manufacturer should be contacted with questions regardingconditions which vary from the guidelines set forth. Standard carpentry knowledge is required and good construc-tion practice for health, safety and welfare must be followed when installing SinoCore®.
TECHNICAL ASSISTANCE
Citadel Architectural Products, Inc.3131-A North Franklin RoadIndianapolis, Indiana 46226phone: (317) 894-9400
(800) 446-8828fax: (317) 894-6333
(800) [email protected]
TABLE OF CONTENTS
Pre-Installation Guidelines.........................................General Work Guidelines...........................................Work Sequence: One Piece Moldings........................Work Sequence: Two Piece Moldings.......................Trim Moldings............................................................Recommended Tooling & Equipment........................Installation Accessories.............................................
259
13171919
SAFETY FIRSTProper protection (i.e. gloves, safety glasses)should be worn at all times to prevent injury fromsharp edges and/or metal shavings.
PROTECT MATERIALWhen installation is not in progress, all paneland accessory units must be kept under protec-tive cover and completely dry.
ENSURE PROPER FITProper fit is very important to the appearance ofthe system. Allowance for expansion is needed,as well as notching and/or mitering of trim.
LIBERALLY APPLY SEALANTALL joints must be sealed against moistureintrusion or the warranty will VOID. If donecorrectly, excess sealant will squeeze from thejoints (to be removed later in the sequence).
REMOVE PROTECTIVE FILMUpon completion, the protective film must beremoved from the painted surface. Failure to doso promptly may cause difficulty in removal andpossibly leave an adhesive residue.
•
•
•
•
•
KEY POINTS FOR ASUCCESSFUL INSTALLATION
MAIN STEPS OF THEINSTALLATION PROCESS
INSTALLATION GUIDELINES 1
FIRST: UNDERSTAND THE SYSTEMUnderstanding the panel system and determiningwhich attachment option has been specified isimperative for completing a proper installation.
SECOND: PRE-PLAN THE INSTALLATIONAfter receiving and properly storing the material,planning the work schedule, grid layout, and materialusage should be performed so that the sequence canproceed without significant delays and/or problems.
THIRD: READ THE GENERAL GUIDELINESThe general guidelines (i.e. fabrication, sealing, etc.)provide a groundwork for all types installations.Thoroughly read and understand these guidelinesbefore beginning the work sequence.
FOURTH: COMPLETE THE WORK SEQUENCEAfter reading the instructions set forth in the generalguidelines, continue to the appropriate work sequenceand complete the installation.
To request a complete Product Manual (whichincludes recommended SECTION and MOLDINGINTERSECTION details), contact the manufacturer.
NOTE:
©2
00
3 C
itad
el
Arc
hite
ctu
ral
Pro
du
cts,
In
c.
An
IS
O 9
00
1:2
00
0 R
eg
iste
red
Co
mpa
ny.
Sin
oC
ore
® i
s a
re
gis
tere
d t
rad
em
ark
of
Cita
de
l A
rch
itect
ura
l P
rod
uct
s, I
nc.
Prin
ted
In T
he U
.S.A
. F
orm
# 7
.02.
IN1.
B
Rev
. (1
1/06
) S
uper
sede
s (0
6/03
)
WARNING: FAILURE TO FOLLOW THESE GUIDELINESWILL VOID THE STANDARD WARRANTY.
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.com
FIGURE A.
2 INSTALLATION GUIDELINES
VISUAL INSPECTION:Upon material arrival, all panel units and molding/accessory cartons should be visually inspected to verifythat the product is in good condition and free fromshipping damage, weather damage or defects.
Shipping damage and/or packaging issues should befirst noted on the bill of lading and then reported tothe distributor.
Should damage occur, the customer is responsiblefor filing a freight claim with the shipping companyWITHIN 24 HOURS from material receipt. Failure to doso may possibly result in forfeit of corrective action.
Any defective material should be reported directly tothe distributor from which the product was purchased.
NOTE:
•
•
•
MATERIAL INVENTORY:After verifying the condition of the product, inventory unitsagainst the packing slip to make sure that all material(including molding and accessory units) is received.
Notify the distributor from which the product waspurchased of any missing or incomplete shipmentsIMMEDIATELY. Failure to do so may result in forfeit ofcorrective action.
NOTE:
TRANSPORTING THE MATERIAL:SinoCore® is packaged from the manufacturer in quanti-ties of 40 pieces (or less) per unit, under cover andsecured with metal strapping (FIG. A). If possible, panelsshould remain in this original packing for transport.
If a forklift or pallet jack is unavailable, panel unit may bebroken and carried to storage by hand according to thefollowing guidelines.
PRE-INSTALLATION:TRANSPORTING & HANDLING
PRE-INSTALLATION:MATERIAL RECEIVING & INVENTORY
IS THE PRODUCT IN GOOD CONDITION?
IS THE PRODUCT CLEAN AND DRY?
IS THE PRODUCT FREE FROM DEFECTS?
...THE MOLDING & ACCESSORY UNITS?
ARE ALL OF THE PANEL UNITS PRESENT?
IS THE PIECE PER UNIT COUNT CORRECT?
HANDLING THE MATERIAL:A strippable protective film (or interleafed foam) isstandard on all panels. This film should remain on theproduct until instructed to take it off (during installationprocedure). This strippable film (FIG. B) is designed toprevent minor abrasions to the surface. However, panelsshould still be handled with care to avoid any majordings, dents or scratches.
FIGURE B.
CLEARPROTECTIVEFILM
PREFINISHEDSURFACE
UNITS ARE CRATEDAND SECURED WITHMETAL STRAPPING
ARROWS WILL BEPRESENT IF MATERIALIS DIRECTIONAL
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com
MATERIAL STORAGE:If the units have been broken, material should berestacked, on a skid. Painted surfaces (strippable filmside) should be placed face to face and any interleafedfoam must be repositioned.
Failure to properly protect material from moistureintrusion may cause damage to the panel surfaceand/or core. Such damage is NOT covered under thestandard warranty.
NOTE:
If the material has become damp or wet during transpor-tation, the surface should be wiped dry before stacking toprevent any type of corrosion. Once the stacking iscompleted (or if the original packaging is still intact), theunits must be covered with a waterproof covering.
All units must be kept in a dry, well-ventilated area awayfrom exposure to the elements and/or any other construc-tion installations which may cause damage to theproduct.
PRE-INSTALLATION:STORING THE MATERIAL UNITS
INSTALLATION GUIDELINES 3
When handling panels, clean work gloves should beworn at all times to protect from sharp edges and toprevent any smudging of the painted finish.
When removing material from shipping units, DO NOTdrag/slide panels across stack underneath. Panelsmust be lifted up, then away to avoid any permanentdamage to the painted surface (FIG. C).
NOTE:
•
•
FIGURE C.
DETERMINING THE GRID:Before beginning the installation procedure, it is importantto plan the overall layout of the installation. Architecturaldrawings should be consulted to determine the correctgrid, where applicable.
If there are no drawings to work from, measure and verifyall field dimensions and develop a pattern to maximizeappearance and minimize fabrication. Consideration foraesthetics should be made in locating odd sized panels.
PRE-INSTALLATION:SCHEDULING & GRID LAYOUT
Once begun, work should not be delayed for longperiods of time at a point which might cause damageto the product if acted upon by external conditions(i.e. rain, snow, long periods of exposure to the sun).
NOTE:
COORDINATION OF WORK:In accordance with good construction practice, schedulethe work to coordinate with other trades so that installa-tion can proceed without significant interference/delay.
DO NOT use butting panels as a guide for grid layout.Actual panel size will vary slightly from grid size(FIG. D) due to the spacing needed for panel expan-sion (1/16”) and the molding/receiver width.
For example, a 4’ x 10’ o.c. grid pattern will result inan actual panel size of slightly less than a full 4’ x 10’.
NOTE:
FIGURE D.
PANELS MUST BELIFTED UP & THEN AWAY,NOT ACROSS THE STACK
PANEL DIM. PANEL DIM.
GRIDDIM.
1/4” (APPROX.)
ONE PIECE MOLDINGS TWO PIECE MOLDINGS
3/8”(APPROX.)
GRIDDIM.
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.com
CALCULATING MATERIAL USAGE:After identifying/determining the grid, begin to verify thatthe correct amount of material has been ordered for yourspecific application. Since material takeoffs and resultingquantities are based upon the grid layout, installing thematerial in another pattern may result in shortages.
Likewise, an approximate cut plan (for both panels andmoldings) should be determined before beginninginstallation to prevent such shortages which may causedelays in completion of the project.
When calculating molding usage, verticals typically passthrough horizontals (FIG. E), except at head and silllocations (see Typical Details). If the project is largeenough to require several lengths of moldings, splicesshould be staggered so that they do not match up withhorizontal/vertical molding intersections (see GeneralWork: Cutting & Fitting Extrusions).
4 INSTALLATION GUIDELINES
ALIGNING & MARKING THE GRID:Using the grid pattern derived, establish a base point inthe lowermost left corner of the elevation (typically).Using a chalk line, level, and a plumb bob, mark thecomplete grid (FIG. F) on the substrate. Doing so willallow for any necessary adjustment to be made prior toinstallation.
Installation may also be started at the center line of theelevation and worked in both directions from that point.
All surfaces of the substrate should be free from anyobstructions and/or projections which might interfere withpanel application. Note areas where shims may berequired to bring the panel system into a plumb, level,and consistent plane.
FIGURE F.
FIGURE E.
TOP OF ELEVATION (HEAD)
BOTTOM OF ELEVATION (SILL)
MARK GRID LINESPLUMB & LEVELON SUBSTRATE
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com INSTALLATION GUIDELINES 5
GENERAL WORK:LIMITATIONS OF THE PANEL SYSTEM
USES & APPLICATIONS:SinoCore® is intended for use as a non-structural wallpanel. It may also be used in other applications wherethe slope does not exceed 25° (FIG. G) past vertical.
Also, the system must be kept a minimum of 12” awayfrom the finished landscaping grade. Other environmen-tal and application limitations may apply. Refer to theProduct Warranty.
GENERAL WORK:FABRICATION OF THE PANELS
SAFETY PRECAUTIONS:When performing fabricating procedures, it is necessaryto observe all general guidelines for safety. Cutting,drilling, or otherwise machining the panels and trimmoldings may produce flying chips, shavings, or dust.
In addition to work gloves and proper clothing, safetygoggles, ear protection, and possibly dust masks maybe needed when fabricating system components.
NOTE:
CUTTING & DRILLING OF PANELS:Cut-to-size panels are available from the manufacturer.When field cutting is required, it may be performed usingstandard carpentry tools equipped with carbide-tippedblades. Work surfaces should be padded (FIG. H) andfree from any debris which may damage the finish. Forcleaner cuts, backer blocks and straightedges
may be clamped to the panel surface. Caul blocks shouldbe used when necessary to protect the painted finish.After cutting, aluminum edges may need filing to removesharp projections and/or metal burrs (FIG. I) that mightprevent the panel from sliding into the molding channelproperly. Doing so will also reduce the risk of personalinjury.
When using a table saw to cut panels, the finished side(protective film) should be placed facing upward. Forhand held circular saws and jigsaws, the finish sideshould be facing down (FIG. J). If working with customcolor panels and a protective film is not present, theinterleafed foam should be placed in a position to protectthe painted finish.
For drilling operations, the finished side should be placedfacing upward and a backer block should be used whennecessary to minimize any tearout.
FIGURE I.
FIGURE G.
FIGURE H.
NOT TO EXCEED25° FROMVERTICAL
NO CLOSERTHAN 12” TO
FINISHEDGRADE
PANEL SYSTEM
WORK SURFACESTO BE PADDED
CAUL BLOCKSSHOULD BE USEDTO PROTECT FINISH
STRAIGHTEDGESSHOULD BE USEDFOR LONG CUTS
METAL BURRSSHOULD BE FILEDSMOOTH ALONGFACE SKIN
HOLD FILE AT ASLIGHT ANGLE
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.com6 INSTALLATION GUIDELINES
The appearance, quality and soundness of the panelsystem depends in large part upon the quality and fit ofthe trim moldings.
For accurate cutting, a miter or chop saw (with carbidetipped blade) is recommended to cut the moldings tolength. Notching of moldings may also be required forsome intersections. Metal snips and/or a miter saw maybe used to remove portions of the moldings so that theintersection can fit together properly (FIG. K).
GENERAL WORK:CUTTING & FITTING MOLDINGS
Whenever cutting, trimming, or installing moldings, itis important to make sure the joints are well fitted andthe intersections formed provide a clean channel intowhich the panel can be placed.
NOTE:
A visual representation of the most common intersectionscan be found in the Typical Details section of the ProductManual. If you have any questions about how yourparticular intersection should be fitted, contact ourtechnical staff for assistance.
SPLICING OF MOLDINGS:Depending on the grid size, several lengths of moldingsmay be required to complete a horizontal and/or verticalrun. Planning should be done to minimize the number ofsplices required.
When necessary, splices must occur no closer than 2”away from a horizontal/vertical intersection (FIG. L).Splices must be completely sealed against moisture.
NOTE:
As a barrier system, SinoCore® is an exterior claddingsystem designed to keep water away from the structuralwall system. Therefore, it is imperative that the followingguidelines be followed accurately to ensure the integrityof the system against moisture intrusion.
SELECTING THE RIGHT SEALANT:In order for the proper bond to be created between thesealant and the system components, be sure to use onlythe sealant recommended by the manufacturer.
GENERAL WORK:PROPER SEALANT APPLICATION
Failure to adequately seal ALL panel edges, moldingintersections & splices, cutouts, etc., will cause theinstallation to fail and will VOID THE WARRANTY.
NOTE:
FIGURE L.
INCORRECT SPLICING CORRECT SPLICING
FIGURE K.
FIGURE J.
CIRCULAR SAW - FINISH DOWN JIGSAW - FINISH DOWN
TABLE SAW - FINISH UP DRILLING - FINISH UP
HORIZTONAL MOLDING
VERTICAL MOLDING
MATERIAL TO BE REMOVED SO THEMOLDING FACES JOIN PROPERLY
2” MIN.
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com
The use of other sealants may require additional steps(such as priming of materials) or cause the installation tofail due to poor weatherability, staining and/or lack ofadequate bonding.
SEALANT APPLICATION:In general, sealant should be liberally applied whereverwater may be able to infiltrate the system (e.g. joints,molding splices, dissimilar material abutments, etc.).
To aid in applying the proper amount of sealant, the tip ofthe sealant tube should be cut at an angle from bothsides (FIG. M). Doing so will allow the tip to act as aguide (and prevent the sealant from getting spread toothin) when applying the bead.
FIGURE N.
ONE PIECE - BEFORE ONE PIECE - AFTER
Depending on the system, the amount of materialrequired to adequately seal the panel may vary slightly.However, squeeze out will always occur if the correctamount of sealant has been applied (FIG. N & O).
For one piece systems, the sealant should fill enough ofthe molding channel (FIG. N) so that squeeze out willoccur when the panel is inserted. For two piece systems,a continuous bead (a minimum of 1/4” x 1/4”) should beplaced along the panel edge before snapping thealuminum cover into place (FIG. O).
INSTALLATION GUIDELINES 7
Excess sealant may be cleaned up (FIG. P) after it ‘skinsover’ (approx. 45 minutes) using a non-marring scraper, aclean rag, and mineral spirits (if necessary).
FIGURE O.
TWO PIECE - BEFORE TWO PIECE - AFTER
Depending upon the fastening schedule and/or panelsize, an adhesive may be required in the field of thepanel. Either double-sided tape or construction adhesivemay be used to adhere the panel to the substrate. Ingeneral, a bead (or strip) of adhesive must be placed ateach intermediate location within the field of the panel(16”-24”o.c.). The approximate size of the bead shouldbe 3/8” (min.) x 2/3 of the panel height. When a moisturebarrier is present, a strip of aluminum (approx. 2”-3” widex 2/3 panel height) must be fastened to the substrate(FIG. Q). The adhesive is then applied to the aluminum.
GENERAL WORK:PROPER ADHESIVE APPLICATION
FIGURE P.
SEALANT SHOULD‘SKIN OVER’ SLIGHTLYBEFORE CLEANING
When abutting dissimilar material (i.e. glazing, brick,etc.), allowances must be made for expansion/contraction(minimum 1/4”). Bond breaker tape should be applied tothe sheathing prior to the application of the receiver andan approved sealant applied after the panel and alumi-num cover are installed (see Typical Details).
FIGURE M.
CUT TIP AT 45° ANGLEFROM BOTH SIDES TOCREATE A GUIDEFOR BEAD SIZE
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.com
For the one piece molding system, panels are attached tothe substrate using construction adhesive and are held inplace by the perimeter molding. The moldings arefastened every 12” along its length.
GENERAL WORK:FASTENING THE PANELS & MOLDINGS
ALL panel fasteners must be driven snug to the panel.DO NOT countersink (or overdrive) the fastener headpast the aluminum skin.
NOTE:
8 INSTALLATION GUIDELINES
FIGURE R.
3/16”
MAINTENANCE OF THEPANEL FINISH
REPAIR/TOUCH UP:Any minor scratches or dings which may occur duringinstallation can be repaired using touch-up paint availablefrom the manufacturer. Repainting of large areas with thetouch-up paint is not recommended. Finish characteris-tics of the repainted surface may vary from the prepaintedaluminum.
MAINTENANCE:Panels should be incorporated into an overall buildingwashing/maintenance schedule and cleaned in accor-dance with AAMA 610.1, Voluntary Guide Specificationfor Cleaning and Maintenance of Painted AluminumExtrusions and Curtain Wall Panels.
In general, panels may be cleaned using warm water anda mild detergrent (if necessary). For more aggressivematerials, a gentle brushing/scrubbing action may berequired. Abrasive detergents and/or harsh solventsshould not be used.
GENERAL WORK:THE PROTECTIVE FILM
When directed to do so (see Work Sequence), theprotective film must be removed from the panel surface.For ease of removal, pull the film back against itself in thesame plane as the panel.
Failure to remove the protective film promptly afterinstallation (or exposure to long periods of sunlight)may cause difficulties in removal and possibly leave anadhesive residue.
NOTE:
FIGURE S.
NO FASTENERSCLOSER THAN 1”FROM THECORNER
FASTENERS TOBE STAGGEREDACROSS THEJOINT 1”-2” APART
PVC RECEIVER
FIGURE Q.
WHEN MOISTURE BARRIER IS PRESENT OVER SUBSTRATE
STRIP OF ALUMINUMFASTENED TO THESUBSTRATE
CONSTRUCTIONADHESIVE
The two piece molding system is applied using pvcreceivers and aluminum extrusions that are ‘snapped’ intoplace after the panel is installed. A reinforcing anchor isplaced in the core of the panel to prevent fasteners fromdimpling the face skin. A pilot hole is then drilled at theanchor location. Panel fasteners are placed 12”-16”around the perimeter 3/16” from the panel edge (FIG. R)and adhesive is applied in the field at 24” o.c. minimum.Perimeter fasteners should be staggered 1”-2” (FIG. S)across the joint for two adjoining panels. Fastenersshould not be placed within 1” of the corner as paneltearout may occur.
PUSH REINFORCINGANCHOR INTO CORE
PRE-DRILL PILOTHOLE
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com INSTALLATION GUIDELINES 9
STEP 1: ATTACHING THE BOTTOMHORIZONTAL & THE LEFT VERTICAL MOLDINGS
Since the installation is progressive, the panel is encap-sulated on all four sides by the one piece moldings.Therefore, the first step in the work sequence is creatingan ‘L’ shaped pocket into which the panel will be placed.
In order to move the installation up, and then across theelevation, the first two moldings to be attached are thebottom horizontal and the left vertical (FIG. 1).
Miter or notch the moldings as needed and then fastenthem to the substrate. Keep in mind that verticals ‘passthrough’ horizontals except at head and sill locations.
The required molding length will vary dependent uponcondition and grid layout.
WORK SEQUENCE:ONE PIECE EXTRUDED MOLDINGS
These guidelines are set forth to show the intent and general sequence of installation. The procedure for eachindividual application and condition may vary. For special conditions or for those not discussed (parapet,dissimilar material, etc.), refer to the General Work Guidelines, Typical Details or contact the manufacturer.
- Nailable Substrate- Non-Nailable Substrate (fastened directly to studs)- Substrate (either type) with Moisture Barrier (special instructions apply)- Furring Strips on Masonry (16”-24” o.c.)
Possible Substrates:
- Panel Fastening (non-mechanical): Panels are attached to the substrate using construction adhesive and are held in place by the perimeter molding.- Molding Fastening: Every 12” along length of molding
- Metal Framing: #S-1000 (1”) or #S-1580 (1-5/8”)- Wood Framing & Sheathing: #S-1001 (1-5/8”)
Types Of Fasteners:
Fastening Schedules:
- Non-Structural, Barrier System
System Type:
- Progressive, moving up and across the elevation beginning at a bottom corner (typical).
Work Flow:
- #5000 (Franklin Titebond™)- #5003-D (Double Sided Tape) A bead (or strip) approx. 2/3 the panel height is placed at intermediate (16”-24”o.c.) locations.
Adhesive:
- #5002 (Tremco® Spectrem® 2) The entire system must be properly sealed against moisture for the warranty to remain valid.
Sealant:- 1/16” between panel perimeter edge and moldingExpansion/Contraction Spacing:
INSTALLATION SPECIFICATIONS:
FIGURE 1.
THE BASE MOLDINGIS INSTALLED 1ST...
THE LEFT VERTICAL IS 2ND
THE APPROPRIATENOTCH/MITER IS TOBE MADE
STOP! READ BEFORE PROCEEDING WITH WORK SEQUENCE
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.com10 INSTALLATION GUIDELINES
STEP 4: INSERTING THE PANEL INTO THEMOLDING CHANNELS
Insert the panel into the moldings (a non-marring scrapermay assist in guiding the panel into the channel). If thecorrect amount of sealant is applied, it should squeeze(FIG. 4) from the molding in a continual bead around thepanel perimeter. The excess will be removed in a laterstep.
STEP 2: PREPARING THE PANEL & APPLYINGTHE SEALANT
Begin by cutting the panel to the proper dimension withallowance made for expansion/contraction. Peel theprotective film away from all four edges of the panel. Donot remove it completely.
Place a large, continuous bead of approved sealant intoboth the bottom horizontal and left vertical moldings(FIG. 2). If the moldings extend past the first panellength/width, apply only enough sealant for one panel.
Failure to adequately seal ALL panel edges will causethe installation to fail and will VOID THE WARRANTY.
NOTE:
STEP 3: APPLYING THE PANEL ADHESIVE
Place a large bead (or strip if using double-sided tape)of panel adhesive onto the substrate at each intermediatelocation (FIG. 3).
The adhesive bead should not be allowed to set upbefore the panel is applied.
NOTE:
FIGURE 4.
FIGURE 2.
FIGURE 3.
ENOUGH SEALANT SHOULD BEAPPLIED SO THAT IT SQUEEZES OUTA CONTINUAL BEAD WHEN THEPANEL IS INSERTED
ADHESIVE ORDOUBLE-SIDED TAPE
SQUEEZE OUT SHOULDOCCUR AT MOLDING EDGE
PROTECTIVE FILM TO BEPULLED BACK FROM PERIMETER
24”MAX.
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com INSTALLATION GUIDELINES 11
STEP 7: CLEANING UP THE EXCESS SEALANTAND REMOVING THE PROTECTIVE FILM
Once the fastening is complete, the excess sealant canbe cleaned from the panel surface using a non-marringscraper, clean rag, and mineral spirits (if necessary).
The scraper should be held at a low angle (FIG. 7) andrun along the perimeter of the panel using the molding asa guide.
Once completed, remove the protective film by pulling itback against itself along the panel.
STEP 6: ATTACHING THE RIGHTVERTICAL MOLDING
After preparing (cutting, applying sealant), the rightvertical should be fastened to the substrate (FIG. 6).
The final molding in the sequence (the right vertical)should never extend past the top horizontal (FIG. 6).Doing so will create a ‘U’ shaped channel and preventthe next panel in the vertical sequence from beinginstalled properly.
NOTE:
STEP 5: ATTACHING THE TOPHORIZONTAL MOLDING
Since verticals typically dominate, the top horizontalmolding should be notched/mitered to ‘dive into’ the leftvertical molding. Likewise the other end of the moldingshould be notched/mitered after being cut to length toreceive the right vertical molding to be attached next.
After the molding has been prepared, apply the properamount of sealant into the channel (only the side facingthe panel) and place it over the edge (FIG. 5). As in theprevious step, sealant squeeze out should occur.
Fasten the top molding to the substrate.
FIGURE 6.
FIGURE 5.
SLIDE THE TOP MOLDINGOVER THE PANEL EDGE
RIGHT VERTICAL SHOULDNOT EXTEND PASTTOP HORIZONTAL
FIGURE 7.
SEALANT SHOULD BE ALLOWEDTO ‘SKIN OVER’ SLIGHTLYBEFORE CLEANING
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.com12 INSTALLATION GUIDELINES
STEP 8: MOVING UP AND ACROSSTHE ELEVATION
Once the first panel is installed, repeat the work se-quence and move vertically in the grid. Upon completionof the first column, move again to the bottom of theelevation and begin at the next column.
Each individual application may vary depending uponlayout. However, moving vertically across the elevationrequires the least amount of setup and may prove themost efficient use of scaffolding and/or power lifts.
FIGURE 8.
COMPLETE THEVERTICAL RUN...
...THEN MOVE TO THE NEXT‘COLUMN’ AND WORK UP &ACROSS THE ELEVATION
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com INSTALLATION GUIDELINES 13
STEP 1: ATTACHING THE PLASTIC RECEIVERSTO THE SUBSTRATE
Being a non-progressive system, the panels are set uponplastic receivers and the edge is encapsulated by analuminum cover molding.
First, attach the bottom horizontal receiver to the sub-strate using a small brad or staple. Next, attach the leftvertical (verticals dominate except at head and silllocations) followed by the right vertical.
Then measure, cut, and attach the top horizontal.
Do not install receivers for more than 3-4 panels at atime. Long exposure to sun may cause misalignment.
NOTE:
WORK SEQUENCE:TWO PIECE EXTRUDED MOLDINGS
These guidelines are set forth to show the intent and general sequence of installation. The procedure for eachindividual application and condition may vary. For special conditions or for those not discussed (parapet,dissimilar material, etc.), refer to the General Work Guidelines, Typical Details or contact the manufacturer.
- Nailable Substrate- Non-Nailable Substrate (fastened directly to studs)- Substrate (either type) with Moisture Barrier (special instructions apply)- Furring Strips on Masonry (16”-24” o.c.)
Possible Substrates:
- Panel Fastening: 12”-16” around panel perimeter—located 3/16” away from edge, driven snug to the panel through the reinforcing anchor, not countersunk (no fasteners within 1” of corner)- Receiver Fastening (temporary): Every 24”-36” along length, using brads/staples
- Metal Framing: #S-1000 (1”) or #S-1580 (1-5/8”)- Wood Framing & Sheathing: #S-1001 (1-5/8”)
Types Of Fasteners:
Fastening Schedules:
- Non-Structural, Barrier System
System Type:
- Non-Progressive, moving up and across the elevation beginning at a bottom corner (typical).
Work Flow:
- #5000 (Franklin Titebond™)- #5003-D (Double Sided Tape) A bead (or strip) approx. 2/3 the panel height is placed at intermediate (16”-24”o.c.) locations.
Adhesive:
- #5002 (Tremco® Spectrem® 2) The entire system must be properly sealed against moisture for the warranty to remain valid.
Sealant:- 1/16” between panel perimeter edge and receiver
Expansion/Contraction Spacing:
INSTALLATION SPECIFICATIONS:
FIGURE 1.
...VERTICALS 2ND...
INSTALL BOTTOM 1ST...
...THEN THE TOP LAST
STOP! READ BEFORE PROCEEDING WITH WORK SEQUENCE
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.com14 INSTALLATION GUIDELINES
STEP 2: PREPARING THE PANEL AND APPLYINGTHE ADHESIVE
Begin by cutting the panel to the proper dimension withallowance made for expansion/contraction.
Next, mark the locations of the perimeter fasteners andinsert the reinforcing anchor into the core. Then, drill thepilot hole through the panel and anchor at each location.
Peel the protective film away from all four edges of thepanel. Do not remove it completely.
Finally, place a large bead (or strip if using double-sidedtape) of panel adhesive onto the substrate at eachintermediate location (FIG. 2).
STEP 3: ATTACHING THE PANEL TOTHE SUBSTRATE
Place the panel onto the receivers (a shim may be helpfulin maintaining the proper spacing (FIG. 3) around theperimeter) and fasten it to the substrate.
STEP 4: REPEATING THE PROCESSFOR ADJOINING PANELS
Because the aluminum covers snap over the edges oftwo panels (with the exception of the perimeter molding),it is necessary to install one or more adjoining panelsbefore continuing.
Repeat STEPS 1-3, installing additional panels in thegrid. Remember to align the vertical receivers so thatthey ‘pass through’ the horizontals (FIG. 4).
The adhesive bead should not be allowed to set upbefore the panel is applied.
DO NOT overdrive fasteners. Doing so will cause theface of the panel to dimple.
NOTE:
•
•
FIGURE 4.
FIGURE 2.
FIGURE 3.
ADHESIVE OR DOUBLE- SIDED TAPE
24”MAX.
SHIMS MAY BE USEDFOR PROPER SPACING
INSTALL ADJOININGPANELS
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com INSTALLATION GUIDELINES 15
STEP 5: CUTTING THE MOLDING & APPLYINGTHE PERIMETER SEALANT
Once the adjoining panels are installed, cut the appropri-ate cover moldings to length making any necessarymiters (if required).
Next, liberally apply a large bead of sealant around thepanel perimeter (FIG. 5).
STEP 6: SNAPPING THE ALUMINUMCOVER INTO PLACE
Once the proper amount of sealant has been applied, thecover molding may be ‘snapped’ into place. Begin at oneend and ‘tap’ the cover molding into place using a rubbermallet, moving along its length (FIG. 6). If the properamount of sealant was applied, a continuous bead shouldsqueeze out from the joint.
STEP 7: CLEANING UP THE EXCESS SEALANTAND REMOVING THE PROTECTIVE FILM
Once the aluminum cover is snapped into place, theexcess sealant can be cleaned from the panel surfaceusing a non-marring scraper, clean rag, and mineralspirits (if necessary).
The scraper should be held at a low angle (FIG. 7) andrun along the perimeter of the panel using the molding asa guide.
Once completed, remove the protective film by pulling itback against itself along the panel.
Apply sealant only to those areas/panels where thecover will be immediately installed.
NOTE:
FIGURE 6.
FIGURE 7.
FIGURE 5.
SEAL ONLY THE PANELEDGES FOR THE 1STSET OF COVERS
TAP MOLDING COVERSINTO RECEIVER MOVINGALONG ITS LENGTH
SEALANT SHOULD BEALLOWED TO ‘SKIN OVER’SLIGHTLY BEFORE CLEANING
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.com16 INSTALLATION GUIDELINES
STEP 8: MOVING UP AND ACROSSTHE ELEVATION
Once the first panel is installed, repeat the work se-quence and move vertically in the grid. Upon completionof the first column, move again to the bottom of theelevation and begin at the next column.
Each individual application may vary depending uponlayout. However, moving vertically across the elevationrequires the least amount of setup and may prove themost efficient use of scaffolding and/or power lifts.
FIGURE 8.
COMPLETE THEVERTICAL RUN...
...THEN MOVE TO THE NEXT‘COLUMN’ AND WORK UP &ACROSS THE ELEVATION
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com INSTALLATION GUIDELINES 17
E-301 HORZ/VERT
ONE PIECE EXTRUDED ALUMINUM MOLDINGS
E-302 O/S CORNER E-303 I/S CORNER E-304 PERIMETER JHeight:Width:Length:
1-1/2” (38mm)1/2” (13mm)12’ (3658mm)
Face Leg:Width:Length:
3/4” (19mm)2” (51mm)12’ (3658mm)
Face Leg:Height:Length:
1/2” (13mm)1-7/8” (48mm)12’ (3658mm)
Face Leg:Height:Length:
1/2” (13mm)1” (25mm)12’ (3658mm)
E-305 DRIP EDGEFace Leg:Height:Length:
1/2” (13mm)1” (25mm)12’ (3658mm)
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.com18 INSTALLATION GUIDELINES
TWO PIECE EXTRUDED ALUMINUM MOLDINGS
C20-401 HORZ/VERT
SC-8240 PVC RECEIVER: 12’
Height:Length:
1-1/2” (38mm)12’ (3658mm)
C20-402 HORZ/VERT
R20-401 PVC RECEIVER: 12’
Height:Length:
1-1/2” (38mm)12’ (3658mm)
SC-604 PERIMETER J
R20-403 PVC RECEIVER: 12’
Height:Length:
1” (25mm)12’ (3658mm)
C20-404 I/S CORNER
R20-404 PVC RECEIVER: 12’
I/S Legs:Length:
3/4” (19mm)12’ (3658mm)
C20-405 O/S CORNER
R20-405 PVC RECEIVER: 12’
O/S Legs:Length:
1-1/4” (32mm)12’ (3658mm)
C20-406 HORZ/VERT
R20-406 PVC RECEIVER: 12’
Height:Reveal:Length:
2” (52mm)1/2” (13mm)12’ (3658mm)
C20-407 PERIMETER J
R20-407 PVC RECEIVER: 12’
Height:Reveal:Length:
1-1/2” (38mm)1/2” (13mm)12’ (3658mm)
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com
Length: 1-5/8” (41mm)Pieces Per Box: 500Weight: 2 lbs.
Item #
MECHANICAL FASTENERS
S-1000CLIMASEALSCREW
S-1580CLIMASEALSCREW
S-1001HI-LOSCREW
Length: 1-5/8” (41mm)Pieces Per Box: 500Weight: 2 lbs.
Length: 1” (25mm)Pieces Per Box: 500Weight: 2 lbs.
Fastening thepanel to woodframing
Fastening thepanel to metalframing
Fastening thepanel to metalframing
Description Application
Small nails or brads (available at a local hardware store) may be used for temporarily attaching the plastic receivers to the substrate.Note: Fasteners shown actual size.
INSTALLATION GUIDELINES 19
Recommended Tooling:
TOOLING & EQUIPMENT
Note: Depending upon your installation, some items may be optional.
Safety GlassesWork GlovesDust MaskHearing Protection
Safety:
ScaffoldingPower LiftPlastic/CanvasCover(s)
Jobsite:
Mild DetergentMineral SpiritsNon-Marring ScraperClean Shop Rags
CleanUp:
Tape Measure(16’ minimum)Laser/Handheld Level(4’ minimum)Chalk LinePlumb BobT-SquareFraming Square
Measuring/Marking:
Framing Hammer(non-marring tip)Rubber Mallet
Hand Tools:
Table SawCircular SawMiter/Chop SawJigsawPower DrillScrew Gun
Power Tools:(carbide tipped blades)
Recommended Equipment:
Caulking GunBox KnifeMetal FileMetal Snips
SawhorsesScrap Sheets OfPlywood (3/4”)Clamps (with cauls)StraightedgePlastic/Wood Shims
Fabrication:
7011-RASINOCORE®
REINFORCINGANCHOR
Length: 7/8” (22mm)Pieces Per Box: 500Weight: 2 lbs.
Inserted into core toprevent the screw fromdimpling the surface
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.com20 INSTALLATION GUIDELINES
SEALANTS, ADHESIVES AND TOUCH-UP
Item # Description
5000 CONSTRUCTIONADHESIVE
Tube Size: 10.5 oz.(approx. 30 lineal ft. pertube at a 1/4” bead)
Application
Along with mechanical fasteners, the panel isadhered to the substrate/stud framework usingconstruction grade adhesive.Franklin Titebond™
5002 SEALANT Tube Size: 11 oz.(approx. 30 lineal ft. pertube at a 1/4” bead)
Proper application of approved sealant is critical tothe integrity of the panel system. Failure to do sowill void the product warranty.
Tremco® Spectrem® 2
5003-D DOUBLE SIDED TAPE 1/8” x 1” x 54’ roll As an alternative to construction adhesive, doublesided tape may be used in some applications toadhere the panel to the substrate.
PA-46 POLYESTERTOUCH-UP PAINT
Container: 7 oz. During installation, minor scratches, abrasions,and/or dings may occur. If necessary, repairs canbe performed using small bottles of color matchedpaint. Touch-up paint should not be used forpainting large areas or trim.
Kynar 500® may also be available.Contact Inside Sales for pricing.
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.
Typical Details:One Piece Molding System
©2
00
3 C
itad
el
Arc
hite
ctu
ral
Pro
du
cts,
In
c.
An
IS
O 9
00
1:2
00
0 R
eg
iste
red
Co
mpa
ny.
Sin
oC
ore
® i
s a
re
gis
tere
d t
rad
em
ark
of
Cita
de
l A
rch
itect
ura
l P
rod
uct
s, I
nc.
Prin
ted
In T
he U
.S.A
. F
orm
# 7
.02.
TD
1.B
R
ev.
(11/
06)
Sup
erse
des
(06/
03)
4
14
11
12
18
15
GENERAL DETAILS
1: SYSTEM ISOMETRIC
2: MOLDING DIMENSIONS
SECTION DETAILS
3A - B: BASE / FOUNDATION
4: HORIZONTAL / VERTICAL
5: INTERMEDIATE CONNECTION
6: DISSIMILAR MATERIAL
7: PARAPET
8A - B: INSIDE CORNER
9A - B: OUTSIDE CORNER
10: CURVED SECTION
INTERSECTION DETAILS
11: BASE INSIDE CORNER
12: BASE OUTSIDE CORNER
13A - B: HORIZONTAL / VERTICAL
14A - B: HORZ / VERT TERMINATION
15: DISSIMILAR MATERIAL CORNER
16: INSIDE CORNER
17: OUTSIDE CORNER
18: THREE WAY INSIDE CORNER
89
5
7
6
16
13
17
3
10
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 1PC 1 System Isometric.dwg
SYSTEM:One Piece Moldings
SCALE:n/a
SINOCORE®
ONE PIECE EXTRUDED
MOLDINGS
FASTENERS
(BY OTHERS)
NAILABLE SUBSTRATE
(BY OTHERS)
NOTE:
FOR NON-NAILABLE
SUBSTRATES, FASTENERS
MUST BE USED ONLY AT
STUD FRAMEWORK
LOCATIONS.
NOTE:
PANEL IS REQUIRED
TO BE EMBEDDED
IN APPROVED SEALANT
(BY OTHERS - NOT SHOWN)
WORKING POINT
IS FACE OF
SUBSTRATE
SYSTEM ISOMETRIC1
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 1PC 2 Molding Dimensions.dwg
SYSTEM:One Piece Moldings
SCALE:1:1
1"
(25mm)
1 1/2"
(38mm)
3/4"
(19mm)
1 1/2"
(38mm)
1 1/2"
(38mm)
1/2"
(13mm)
1"
(25mm)
1/2"
(13mm)
E-301
HORZ / VERT
E-302
OUTSIDE CORNER
E-303
INSIDE CORNER
E-304
PERIMETER J
MOLDING DIMENSIONS2
E-305
DRIP EDGE
1"
(25mm)
3/4"
(19mm)
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 1PC 3A Base Foundation Option 1.dwg
SYSTEM:One Piece Moldings
SCALE:1:1
SINOCORE®
NAILABLE SUBSTRATE
(BY OTHERS)
NOTE:
FOR NON-NAILABLE
SUBSTRATES, FASTENERS
MUST BE USED ONLY
AT STUD FRAMEWORK
LOCATIONS
FASTENER
(BY OTHERS)
E-304
PERIMETER J
APPROVED SEALANT
(BY OTHERS)
FOUNDATION
(BY OTHERS)
BASE / FOUNDATION, OPTION 13A
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 1PC 3B Base Foundation Option 2.dwg
SYSTEM:One Piece Moldings
SCALE:1:1
SINOCORE®
NAILABLE SUBSTRATE
(BY OTHERS)
NOTE:
FOR NON-NAILABLE
SUBSTRATES, FASTENERS
MUST BE USED ONLY
AT STUD FRAMEWORK
LOCATIONS
FASTENER
(BY OTHERS)
E-305
DRIP EDGE
APPROVED SEALANT
(BY OTHERS)
FOUNDATION
(BY OTHERS)
BASE / FOUNDATION, OPTION 23B
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 1PC 4 Horizontal Vertical.dwg
SYSTEM:One Piece Moldings
SCALE:1:1
FASTENER
(BY OTHERS)
NAILABLE SUBSTRATE
(BY OTHERS)
NOTE:
FOR NON-NAILABLE
SUBSTRATES, FASTENERS
MUST BE USED ONLY
AT STUD FRAMEWORK
LOCATIONS
SINOCORE®
E-301
HORZ / VERT
APPROVED
SEALANT
(BY OTHERS)
HORIZONTAL / VERTICAL4
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 1PC 5 Intermediate Connection.dwg
SYSTEM:One Piece Moldings
SCALE:1:1
SINOCORE®
APPROVED
CONSTRUCTION
ADHESIVE
(BY OTHERS)
NAILABLE SUBSTRATE
(BY OTHERS)NOTE:
FOR NON-NAILABLE SUBSTRATES,
FASTENERS MUST BE USED ONLY
AT STUD FRAMEWORK LOCATIONS.
NOTE:
IF MOISTURE BARRIER IS PRESENT,
SPECIAL INSTRUCTIONS APPLY,
REFER TO INSTALLATION GUIDELINES.
INTERMEDIATE CONNECTION5
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 1PC 6 Dissimilar Material.dwg
SYSTEM:One Piece Moldings
SCALE:1:1
SINOCORE®
NOTE:
FOR NON-NAILABLE SUBSTRATES,
FASTENERS MUST BE USED ONLY
AT STUD FRAMEWORK LOCATIONS
E-304
PERIMETER J
NAILABLE SUBSTRATE
(BY OTHERS) FASTENER
(BY OTHERS)
DISSIMILAR MATERIAL6
VARIES
(3/8" TO 1/2")
BOND BREAKER
TAPE
(BY OTHERS)
DISSIMILAR
MATERIAL
(BY OTHERS)
APPROVED
SEALANT
(BY OTHERS)
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 1PC 7 Parapet.dwg
SYSTEM:One Piece Moldings
SCALE:1:1
BLOCKING
(BY OTHERS)
ALUMINUM
FLASHING
(BY OTHERS)
FASTENER
(BY OTHERS)
7011-RA
REINFORCING
ANCHOR
APPROVED
SEALANT
(BY OTHERS)
SINOCORE®
NAILABLE
SUBSTRATE
(BY OTHERS)
PARAPET7
SHIM AS NEEDED
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 1PC 8A Inside Corner Option 1.dwg
SYSTEM:One Piece Moldings
SCALE:1:1
SINOCORE®
E-303
I/S CORNER
FASTENER
(BY OTHERS)
NAILABLE
SUBSTRATE
(BY OTHERS)
NOTE:
FOR NON-NAILABLE
SUBSTRATES, FASTENERS
MUST BE USED ONLY
AT STUD FRAMEWORK
LOCATIONS
APPROVED SEALANT
(BY OTHERS)
INSIDE CORNER, OPTION 18A
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 1PC 8B Inside Corner Option 2.dwg
SYSTEM:One Piece Moldings
SCALE:1:1
NAILABLE
SUBSTRATE
(BY OTHERS)
SINOCORE®
INSIDE CORNER, OPTION 28B
FIELD ROUTED
AND BENT
APPROVED CONSTRUCTION
ADHESIVE (BY OTHERS) MAY
BE REQUIRED DEPENDING
UPON PANEL SPAN
(REFER TO INSTALLATION
INSTRUCTIONS)
FACE SKIN MUST
BE .024" (MIN) ALUMINUM
TO UTILIZE THIS OPTION
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 1PC 9A Outside Corner Option 1.dwg
SYSTEM:One Piece Moldings
SCALE:1:1
FASTENER
(BY OTHERS)
E-302
O/S CORNER
APPROVED
SEALANT
(BY OTHERS)
SINOCORE®
NAILABLE SUBSTRATE
(BY OTHERS)
NOTE:
FOR NON-NAILABLE
SUBSTRATES, FASTENERS
MUST BE USED ONLY AT
STUD FRAMEWORK
LOCATIONS
OUTSIDE CORNER, OPTION 19A
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 1PC 9B Outside Corner Option 2.dwg
SYSTEM:One Piece Moldings
SCALE:1:1
SINOCORE®
OUTSIDE CORNER, OPTION 29B
NAILABLE
SUBSTRATE
(BY OTHERS)
FIELD ROUTED
AND BENT
APPROVED CONSTRUCTION
ADHESIVE (BY OTHERS) MAY
BE REQUIRED DEPENDING
UPON PANEL SPAN
(REFER TO INSTALLATION
INSTRUCTIONS)
FACE SKIN MUST
BE .024" (MIN) ALUMINUM
TO UTILIZE THIS OPTION
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 1PC 10 Curved Section.dwg
SYSTEM:One Piece Moldings
SCALE:n/a
FACE SKIN
NOTE:
FOR COLUMN COVERS,
PLEASE REFER TO THE
ENVELOPE 2000® RR SYSTEM.
CURVED SECTION10
PARAMETERS FOR FIELD CURVING SINOCORE® PANELS*:
BACKER MATERIAL**:
STANDARD .024" SMOOTH ALUMINUM
.030" SMOOTH FIBERGLASS REINFORCED PLASTIC (FRP)
.008" FIBERGLASS REINFORCED KRAFT/FOIL SCRIM
* ALL MOLDINGS MUST BE FACTORY CURVED. HOWEVER, FACTORY
CURVING NOT RECOMMENDED FOR SINOCORE® PANELS.
** FACE MATERIAL MUST BE .024" (MIN) ALUMINUM.
NOTE:
FOR SPECIFIC PROJECT REQUIREMENTS, CONTACT CITADEL.
MINIMUM RADIUS:
50 FT
8 FT
2 FT
BACK SKIN
SINOCORE®
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 1PC Intersections 11 To 13B.dwg
SYSTEM:One Piece Moldings
SCALE:n/a
E-302
O/S CORNER
MITERED AROUND
THE CORNER AT 45°
NOTCHED AND
REMOVED
BASE INSIDE CORNER11 BASE OUTSIDE CORNER12
E-301
HORZ / VERT
HORIZONTAL / VERTICAL, OPTION 113A HORIZONTAL / VERTICAL, OPTION 213B
MITERED AT 45°
NOTCHED
AND REMOVED
E-303
I/S CORNER
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 1PC 14A To 15.dwg
SYSTEM:One Piece Moldings
SCALE:n/a
MITERED AT 45°
NOTCHED AND REMOVED
E-304
PERIMETER J
HORZ / VERT TERMINATION, OPTION 114A HORZ / VERT TERMINATION, OPTION 214B
NOTCHED AND
REMOVED
DISSIMILAR MATERIAL CORNER15
BACKER ROD (IF
NECESSARY) AND
APPROVED SEALANT
(BY OTHERS)
E-301
HORZ / VERTE-304
PERIMETER J
DISSIMILAR
MATERIAL
(BY OTHERS)
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 1PC Intersections 16 To 18.dwg
SYSTEM:One Piece Moldings
SCALE:n/a
ALL THREE
MOLDINGS
TO BE MITERED
AT 45° ON
EACH LEGE-303
I/S CORNER
THREE WAY INSIDE CORNER18
INSIDE CORNER16
E-303
I/S CORNER
E-301
HORZ / VERT
NOTCHED
AND
REMOVED
E-302
O/S CORNER
OUTSIDE CORNER17
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.
Typical Details:Two Piece Molding System
©2
00
3 C
itad
el
Arc
hite
ctu
ral
Pro
du
cts,
In
c.
An
IS
O 9
00
1:2
00
0 R
eg
iste
red
Co
mpa
ny.
Sin
oC
ore
® i
s a
re
gis
tere
d t
rad
em
ark
of
Cita
de
l A
rch
itect
ura
l P
rod
uct
s, I
nc.
Prin
ted
In T
he U
.S.A
. F
orm
# 7
.02.
TD
2.B
R
ev.
(11/
06)
Sup
erse
des
(06/
03)
4
14
11
12
18
17
GENERAL DETAILS
1A - C: SYSTEM ISOMETRIC
2A - B: MOLDING DIMENSIONS
SECTION DETAILS
3A - B: BASE / FOUNDATION
4A - C: HORIZONTAL / VERTICAL
5: INTERMEDIATE CONNECTION
6A - B: DISSIMILAR MATERIAL
7: PARAPET
8A - B: INSIDE CORNER
9A - B: OUTSIDE CORNER
10: CURVED SECTION
INTERSECTION DETAILS
11A - B: BASE INSIDE CORNER
12A - B: BASE OUTSIDE CORNER
13A - E: HORIZONTAL / VERTICAL
14A - D: HORZ / VERT TERMINATION
15: HORZ TERMINATION ONLY
16A - C: DISSIMILAR MATERIAL CORNER
17: THREE WAY INSIDE CORNER
18A - D: INSIDE CORNER
19A - D: OUTSIDE CORNER
89
5
7
6
15
13
16
3
10
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 2PC 1A System Isometric Option 1.dwg
SYSTEM:Two Piece Moldings
SCALE:n/a
WORKING POINT
IS FACE OF
SUBSTRATE
NOTE:
PANEL IS REQUIRED
TO BE EMBEDDED
IN APPROVED SEALANT
(BY OTHERS - NOT SHOWN)
NOTE:
FOR NON-NAILABLE
SUBSTRATES, FASTENERS
MUST BE USED ONLY AT
STUD FRAMEWORK
LOCATIONS.
NAILABLE SUBSTRATE
(BY OTHERS)
CONCEALED
FASTENERS
(BY OTHERS)
TWO PIECE EXTRUDED
MOLDINGS
SINOCORE®
SYSTEM ISOMETRIC, OPTION 11A
PVC RECEIVERS
REINFORCING
ANCHORS
(NOT SHOWN)
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 2PC 1B System Isometric Option 2.dwg
SYSTEM:Two Piece Moldings
SCALE:n/a
CONCEALED
FASTENERS
(BY OTHERS)
TWO PIECE (REVEAL)
EXTRUDED MOLDINGS
SINOCORE®
NOTE:
PANEL IS REQUIRED
TO BE EMBEDDED
IN APPROVED SEALANT
(BY OTHERS - NOT SHOWN)
WORKING POINT
IS FACE OF
SUBSTRATE
NOTE:
FOR NON-NAILABLE
SUBSTRATES, FASTENERS
MUST BE USED ONLY AT
STUD FRAMEWORK
LOCATIONS.
NAILABLE SUBSTRATE
(BY OTHERS)
SYSTEM ISOMETRIC, OPTION 21B
PVC RECEIVERS
REINFORCING
ANCHORS
(NOT SHOWN)
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 2PC 1C System Isometric Option 3.dwg
SYSTEM:Two Piece Moldings
SCALE:n/a
WORKING POINT
IS FACE OF
SUBSTRATE
NOTE:
PANEL IS REQUIRED
TO BE EMBEDDED
IN APPROVED SEALANT
(BY OTHERS - NOT SHOWN)
NOTE:
FOR NON-NAILABLE
SUBSTRATES, FASTENERS
MUST BE USED ONLY AT
STUD FRAMEWORK
LOCATIONS.
NAILABLE SUBSTRATE
(BY OTHERS)
CONCEALED
FASTENERS
(BY OTHERS)
TWO PIECE EXTRUDED
MOLDINGS
SINOCORE®
SYSTEM ISOMETRIC, OPTION 31C
REINFORCING
ANCHORS
(NOT SHOWN)
PVC RECEIVERS
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 2PC 2A Molding Dimensions Page 1.dwg
SYSTEM:Two Piece Moldings
SCALE:1:1
1/4"
(6mm)
1 1/2"
(38mm)
1/4"
(6mm)
1/4"
(6mm)
1 1/4"
(32mm)
C20-401
HORZ / VERT
SC-8240
PVC RECEIVER
3/4"
(19mm)
1 1/2"
(38mm)
C20-402
HORZ / VERT
SC-8240
PVC RECEIVER
SC-604
PERIMETER J
R20-403
PVC RECEIVER
C20-405
OUTSIDE CORNER
R20-405
PVC RECEIVER
C20-404
INSIDE CORNER
R20-404
PVC RECEIVER
7/16"
(11mm)
1"
(25mm)
1/4"
(6mm)
MOLDING DIMENSIONS, PAGE 12A
11/16"
(17mm)
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 2PC 2B Molding Dimensions Page 2.dwg
SYSTEM:Two Piece Moldings
SCALE:1:1
C20-407
PERIMETER J
R20-407
PVC RECEIVER
C20-406
HORZ / VERT
R20-406
PVC RECEIVER
1/4"
(6mm)
1/2"
(13mm)2"
(51mm)
5/16"
(8mm)
1/2"
(13mm)
1 1/2"
(38mm)
1/4"
(6mm)
MOLDING DIMENSIONS, PAGE 22B
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 2PC 3A Base Foundation Option 1.dwg
SYSTEM:Two Piece Moldings
SCALE:1:1
SINOCORE®
SC-604
PERIMETER J
APPROVED
SEALANT
(BY OTHERS)
ALUMINUM
FLASHING
(BY OTHERS)
FOUNDATION
(BY OTHERS)
FASTENER
(BY OTHERS)
NAILABLE SUBSTRATE
(BY OTHERS)
NOTE:
FOR NON-NAILABLE
SUBSTRATES, FASTENERS
MUST BE USED ONLY AT
STUD FRAMEWORK
LOCATIONS
R20-403
PVC RECEIVER
7011-RA
REINFORCING
ANCHOR
BASE / FOUNDATION, OPTION 13A
BOND BREAKER
TAPE
(BY OTHERS)
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 2PC 3B Base Foundation Option 2.dwg
SYSTEM:Two Piece Moldings
SCALE:1:1
NOTE:
FOR NON-NAILABLE
SUBSTRATES, FASTENERS
MUST BE USED ONLY AT
STUD FRAMEWORK
LOCATIONS
NAILABLE SUBSTRATE
(BY OTHERS)
FASTENER
(BY OTHERS)
R20-407
PVC RECEIVER
SINOCORE®
C20-407
PERIMETER J
APPROVED SEALANT
(BY OTHERS)
BASE / FOUNDATION, OPTION 23B
BOND BREAKER
TAPE
(BY OTHERS)
FOUNDATION
(BY OTHERS)
ALUMINUM
FLASHING
(BY OTHERS)
7011-RA
REINFORCING
ANCHOR
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 2PC 4A Horizontal Vertical Option 1.dwg
SYSTEM:Two Piece Moldings
SCALE:1:1
SINOCORE®
C20-401
HORZ / VERT
7011-RA
REINFORCING
ANCHOR
APPROVED
SEALANT
(BY OTHERS)
FASTENER
(BY OTHERS)
NAILABLE SUBSTRATE
(BY OTHERS)
NOTE:
FOR NON-NAILABLE
SUBSTRATES, FASTENERS
MUST BE USED ONLY
AT STUD FRAMEWORK
LOCATIONS
SC-8240
PVC RECEIVER
HORIZONTAL / VERTICAL, OPTION 14A
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 2PC 4B Horizontal Vertical Option 2.dwg
SYSTEM:Two Piece Moldings
SCALE:1:1
NOTE:
FOR NON-NAILABLE
SUBSTRATES, FASTENERS
MUST BE USED ONLY AT
STUD FRAMEWORK
LOCATIONS
NAILABLE SUBSTRATE
(BY OTHERS)
FASTENER
(BY OTHERS)
R20-406
RECEIVER
SINOCORE®
C20-406
HORZ / VERT
APPROVED SEALANT
(BY OTHERS)
HORIZONTAL / VERTICAL, OPTION 24B
7011-RA
REINFORCING
ANCHOR
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 2PC 4C Horizontal Vertical Option 3.dwg
SYSTEM:Two Piece Moldings
SCALE:1:1
7011-RA
REINFORCING
ANCHOR
APPROVED
SEALANT
(BY OTHERS)
C20-402
EXTRUSION
SINOCORE®
FASTENER
(BY OTHERS)
SC-8240
PVC RECEIVER
NOTE:
FOR NON-NAILABLE
SUBSTRATES, FASTENERS
MUST BE USED ONLY
AT STUD FRAMEWORK
LOCATIONS
NAILABLE SUBSTRATE
(BY OTHERS)
HORIZONTAL / VERTICAL, OPTION 34C
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 2PC 5 Intermediate Connection.dwg
SYSTEM:Two Piece Moldings
SCALE:1:1
SINOCORE®
APPROVED
CONSTRUCTION
ADHESIVE
(BY OTHERS)
NAILABLE SUBSTRATE
(BY OTHERS)NOTE:
FOR NON-NAILABLE SUBSTRATES,
FASTENERS MUST BE USED ONLY
AT STUD FRAMEWORK LOCATIONS.
NOTE:
IF MOISTURE BARRIER IS PRESENT,
SPECIAL INSTRUCTIONS APPLY,
REFER TO INSTALLATION GUIDELINES.
INTERMEDIATE CONNECTION5
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 2PC 6A Dissimilar Material Option 1.dwg
SYSTEM:Two Piece Moldings
SCALE:1:1
SINOCORE®
7011-RA
REINFORCING
ANCHOR
SC-604
PERIMETER J
FASTENER
(BY OTHERS)
NAILABLE SUBSTRATE
(BY OTHERS)
NOTE:
FOR NON-NAILABLE SUBSTRATES,
FASTENERS MUST BE USED ONLY
AT STUD FRAMEWORK LOCATIONS
R20-403
PVC RECEIVER
DISSIMILAR MATERIAL, OPTION 16A
BOND BREAKER
TAPE
(BY OTHERS)
DISSIMILAR
MATERIAL
(BY OTHERS)
APPROVED
SEALANT
(BY OTHERS) VARIES
(3/8" TO 1/2")
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 2PC 6B Dissimilar Material Option 2.dwg
SYSTEM:Two Piece Moldings
SCALE:1:1
C20-407
PERIMETER J
SINOCORE®
NOTE:
FOR NON-NAILABLE SUBSTRATES,
FASTENERS MUST BE USED ONLY
AT STUD FRAMEWORK LOCATIONS
NAILABLE SUBSTRATE
(BY OTHERS)
FASTENER
(BY OTHERS)
R20-407
PVC RECEIVER
DISSIMILAR MATERIAL, OPTION 26B
DISSIMILAR
MATERIAL
(BY OTHERS)
BOND
BREAKER
TAPE
(BY OTHERS)
APPROVED
SEALANT
(BY OTHERS)
VARIES
(3/8" TO 1/2")
7011-RA
REINFORCING
ANCHOR
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 2PC 7 Parapet.dwg
SYSTEM:Two Piece Moldings
SCALE:1:1
BLOCKING
(BY OTHERS)
ALUMINUM
FLASHING
(BY OTHERS)
FASTENER
(BY OTHERS)
7011-RA
REINFORCING
ANCHOR
APPROVED
SEALANT
(BY OTHERS)
SINOCORE®
NAILABLE
SUBSTRATE
(BY OTHERS)
NOTE:
FOR NON-NAILABLE
SUBSTRATES, FASTENERS
MUST BE USED ONLY
AT STUD FRAMEWORK
LOCATIONS
PARAPET7
SHIM AS NEEDED
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 2PC 8A Inside Corner Option 1.dwg
SYSTEM:Two Piece Moldings
SCALE:1:1
SINOCORE®
7011-RA
REINFORCING ANCHOR
C20-404
I/S CORNER
APPROVED SEALANT
(BY OTHERS)
FASTENER
(BY OTHERS)
NAILABLE SUBSTRATE
(BY OTHERS)
NOTE:
FOR NON-NAILABLE
SUBSTRATES, FASTENERS
MUST BE USED ONLY
AT STUD FRAMEWORK
LOCATIONS
R20-404
PVC RECEIVER
INSIDE CORNER, OPTION 18A
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 2PC 8B Inside Corner Option 2.dwg
SYSTEM:Two Piece Moldings
SCALE:1:1
NAILABLE
SUBSTRATE
(BY OTHERS)
SINOCORE®
INSIDE CORNER, OPTION 28B
FIELD ROUTED
AND BENT
APPROVED CONSTRUCTION
ADHESIVE (BY OTHERS) MAY
BE REQUIRED DEPENDING
UPON PANEL SPAN
(REFER TO INSTALLATION
INSTRUCTIONS)
FACE SKIN MUST
BE .024" (MIN) ALUMINUM
TO UTILIZE THIS OPTION
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 2PC 9A Outside Corner Option 1.dwg
SYSTEM:Two Piece Moldings
SCALE:1:1
SINOCORE®
R20-405
PVC RECEIVER
C20-405
O/S CORNER
APPROVED
SEALANT
(BY OTHERS)
FASTENER
(BY OTHERS)7011-RA
REINFORCING
ANCHOR
NAILABLE SUBSTRATE
(BY OTHERS)
NOTE:
FOR NON-NAILABLE
SUBSTRATES, FASTENERS
MUST BE USED ONLY
AT STUD FRAMEWORK
LOCATIONS
OUTSIDE CORNER, OPTION 19A
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 2PC 9B Outside Corner Option 2.dwg
SYSTEM:Two Piece Moldings
SCALE:1:1
SINOCORE®
OUTSIDE CORNER, OPTION 29B
NAILABLE
SUBSTRATE
(BY OTHERS)
FIELD ROUTED
AND BENT
APPROVED CONSTRUCTION
ADHESIVE (BY OTHERS) MAY
BE REQUIRED DEPENDING
UPON PANEL SPAN
(REFER TO INSTALLATION
INSTRUCTIONS)
FACE SKIN MUST
BE .024" (MIN) ALUMINUM
TO UTILIZE THIS OPTION
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 2PC 10 Curved Section.dwg
SYSTEM:Two Piece Moldings
SCALE:n/a
SINOCORE™
NOTE:
PANELS AND MOLDINGS CAN
BE EITHER CURVED IN THE
FIELD OR FACTORY CURVED,
DEPENDING ON RADIUS DESIRED.
CONTACT CITADEL WITH SPECIFIC
PROJECT REQUIREMENTS.
FOR COLUMN COVERS,
PLEASE REFER TO THE
ENVELOPE 2000® RR SYSTEM.
CURVED SECTION10
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 2PC Intersections 11A To 12B.dwg
SYSTEM:Two Piece Moldings
SCALE:n/a
C20-405
O/S CORNER
C20-404
I/S CORNER
R20-403
PVC RECEIVER
MITERED AROUND
THE CORNER AT 45°
SC-604
PERIMETER J
R20-407
PVC RECEIVER
R20-404
PVC RECEIVER
C20-404
I/S CORNER
MITERED AT
45° AROUND
THE CORNER
R20-405
PVC RECEIVER
C20-407
PERIMETER J
C20-405
O/S CORNER
BASE INSIDE CORNER, OPTION 111A BASE INSIDE CORNER, OPTION 211B
BASE OUTSIDE CORNER, OPTION 112A BASE OUTSIDE CORNER, OPTION 212B
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 2PC Intersections 13A To 13D.dwg
SYSTEM:Two Piece Moldings
SCALE:n/a
MITERED AT 45°
C20-401
HORZ / VERT
SC-8240
PVC RECEIVER
MITERED
AT 45°
GAP TO BE
FILLED WITH
APPROVED
SEALANT
R20-401
PVC RECEIVER
C20-406
HORZ / VERT
HORIZONTAL / VERTICAL, OPTION 113A HORIZONTAL / VERTICAL, OPTION 213B
HORIZONTAL / VERTICAL, OPTION 313C HORIZONTAL / VERTICAL, OPTION 413D
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 2PC Intersections 13E To 14C.dwg
SYSTEM:Two Piece Moldings
SCALE:n/a
C20-401
HORZ / VERT
C20-401
HORZ / VERT
MITERED
AT 45°
C20-403
PERIMETER JMITERED
AT 45°
SC-8240
PVC RECEIVER
MITERED
AT 45°
HORIZONTAL / VERTICAL, OPTION 513E HORZ / VERT TERMINATION, OPTION 114A
HORZ / VERT TERMINATION, OPTION 214B HORZ / VERT TERMINATION, OPTION 314C
SC-604
PERIMETER J
R20-406
PVC RECEIVER
C20-406
HORZ / VERT
C20-402
HORZ / VERT
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 2PC Intersections 14D To 15.dwg
SYSTEM:Two Piece Moldings
SCALE:n/a
R20-407
PVC RECEIVER
GAP TO BE
FILLED WITH
APPROVED
SEALANT
SC-604
PERIMETER J
R20-403
PVC
RECEIVER
C20-402
HORZ / VERT
HORZ / VERT TERMINATION, OPTION 414D HORIZONTAL TERMINATION ONLY15
C20-407
PERIMETER J
C20-406
HORZ / VERT
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 2PC Intersections 16A To 17.dwg
SYSTEM:Two Piece Moldings
SCALE:n/a
R20-407
PVC RECEIVER
C20-407
PERIMETER J
BACKER ROD (IF
NECESSARY) AND
APPROVED SEALANT
(BY OTHERS)
ALL THREE
MOLDINGS TO
BE MITERED
AT 45° ON
EACH LEG
SC-8240
PVC RECEIVER
MITERED
AT 45°
C20-401
HORZ / VERT
R20-403
PVC RECEIVER
SC-604
PERIMETER J
DISSIMILAR
MATERIAL
(BY OTHERS)
DISSIMILAR MATERIAL CORNER, OPT. 116A DISSIMILAR MATERIAL CORNER, OPT. 216B
DISSIMILAR MATERIAL CORNER, OPT. 316C THREE WAY INSIDE CORNER17
R20-406
RECEIVER
C20-406
HORZ / VERT
C20-402
HORZ / VERT
SC-8240
PVC RECEIVER
R20-404
PVC RECEIVER
C20-404
I/S CORNER
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.REVISED:
11/06
DRAWING NAME:SIN 2PC Intersections 18A To 18D.dwg
SYSTEM:Two Piece Moldings
SCALE:n/a
C20-404
I/S CORNER
GAP TO BE
FILLED WITH
APPROVED
SEALANT
R20-406
PVC RECEIVER
C20-404
I/S CORNER
R20-404
PVC RECEIVER MITERED AT
45° AROUND
CORNER
C20-402
HORZ / VERT
SC-8240
PVC RECEIVER
R20-404
PVC RECEIVER
INSIDE CORNER, OPTION 118A INSIDE CORNER, OPTION 218B
INSIDE CORNER, OPTION 318C INSIDE CORNER, OPTION 418D
C20-406
HORZ / VERT
C20-401
HORZ / VERT
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com TYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details. REVISED:
11/06
DRAWING NAME:SIN 2PC Intersections 19A To 19D.dwg
SYSTEM:Two Piece Moldings
SCALE:n/a
R20-405
PVC RECEIVER
C20-405
O/S CORNER
GAP TO BE
FILLED WITH
APPROVED
SEALANT
C20-406
HORZ / VERT
MITERED AT
45° AROUND
CORNER
SC-8240
PVC RECEIVER
C20-405
O/S CORNER
C20-401
HORZ / VERT
OUTSIDE CORNER, OPTION 119A OUTSIDE CORNER, OPTION 219B
OUTSIDE CORNER, OPTION 319C OUTSIDE CORNER, OPTION 419D
C20-402
HORZ / VERT
R20-401
PVC RECEIVER
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comTYPICAL DETAILS
Note: This detail represents the latest recommendations from CitadelArchitectural Products, Inc. It is presented in good faith and is subject tochange without notice. Citadel Architectural Products, Inc. accepts noresponsibility for the end use of this detail. For conditions not shown,consult our Technical Staff at (800) 446-8828 for review of specific details.
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com GUIDE SPECIFICATION
B.
1.06 SUBMITTALSA.
B.
C.
Architectural AluminumManufacturer’s Association(AAMA):
(Specifier Note: Article belowincludes submittal of relevant datato be furnished by Contractoreither before, during or afterconstruction. Coordinate thisarticle with Architect’s andContractor’s duties and responsi-bilities in Conditions of theContract and Division 1 SubmittalProcedures Section.)
Samples:Panel: Two (2) 3”x 5” samples ofeach type of assembly.Color Standards: Two (2) 3”x 5”samples of each color of finishselected.
Shop Drawings: Indicate thicknessand dimension of parts, fasteningand anchoring methods, detailand location of joints, includingjoints necessary to accomodatethermal movement.
Material Certification: Two (2)copies certifying that materialmeets the requirements specified.
1.
2.
3.
AAMA 2603-98: VoluntarySpecification, PerformanceRequirements and TestProcedures for PigmentedOrganic Coatings on AluminumExtrusions and Panels.
AAMA 2605-98: VoluntarySpecification, PerformanceRequirements and TestProcedures for SuperiorPerforming Organic Coatingson Aluminum Extrusions andPanels
AAMA 611-98: VoluntarySpecification for AnodizedArchitectural Aluminum
E.
1.04 QUALITY ASSURANCEA.
B.
C.
D.
1.05 REFERENCESA.
SECTION 07415: EXTERIOR WALLPANELS & SYSTEMS
1.01 WORK INCLUDED
1.02 RELATED SECTIONSA.B.C.D.E.F.
1.03 SYSTEM DESCRIPTIONA.
B.
C.
D.
Guide Specification
(Specifier Note: This is a guide specification for prefinished architectural panels as manufactured by Citadel Architec-tural Products, Inc. and marketed under the trade name SinoCore®. Revise section number and title below to suitproject requirements, specification practices and section content. Options are indicated by brackets { }: delete non-selected text in final copy of specification.)
PART 1: GENERAL
Section Includes: Laminatedpanels and attachment systemsfor use as exterior cladding.
(Specifier Note: Revise articlebelow to suit project requirements.Add section numbers and title’sper specifier’s practice.)
Section 05100: Structural FramingSection 06100: Back Up WallsSection 07299: InsulationSection 07600: Metal FlashingSection 07920: SealantsSection 09200: Finishes
(Specifier Note: Revise articlebelow to suit project requirements.Restrict to statements describingdesign or performance require-ments of the complete wallsystem.)
Panel’s exposed finishes shallperform according to AAMA 2603-98 or AAMA 2605-98; exposedanodized aluminum according toAAMA 611-98.
Panel composite assembly shallconform to ASTM E84, FlameSpread, Class A.
Design wall system to withstand apositive and negative windloadpressure acting inward andoutward normal to the plane of thewall to meet the requirements ofthe latest adopted Local BuildingCode.
Make adequate provisions in thewall system for thermal expansionand contraction of the component
parts and fastening of the systemto prevent harmful damagecaused by buckling, opening ofjoints, expasion and contractiondue to accumulation of dead loadsand various live loads.
Design wall system to be sealedat all joints, intersections andcutouts to prevent moistureintrusion of any type.
Panel Manufacturer: Manufacturershall have a minimum of ten (10)years experience in the manufac-ture of composite architecturalwall systems and must haveISO 9001:2000 Certification.
Panel Installer: Installer shall beexperienced in performing work ofthis section and be specialized inthe installation of similar workrequired on this project.
Field Measurements: Whenpossible, measurements shouldbe taken prior to the completion ofshop manufacturing andassembly.
Pre-Installation Meetings: Conductpre-installation meetings to verifyproject requirements, substratecondition, installation instructions,and warranty requirements.Comply with Division 1 ProjectManagement and Coordination,Project Meetings Section.
(Specifier Note: Articles below listindustry standards referenced inthis section.)
American Society for Testing andMaterials (ASTM):
ASTM E84: Surface BurningCharacteristics
©2
00
3 C
itad
el A
rch
itect
ura
l Pro
du
cts,
In
c.
An
IS
O 9
00
1:2
00
0 R
eg
iste
red
Co
mp
an
y.S
ino
Co
re® is
a r
eg
iste
red
tra
de
ma
rk o
f C
itad
el A
rch
itect
ura
l Pro
du
cts,
In
c.P
rin
ted
In
Th
e U
.S.A
. F
orm
# 7
.02
.SP
1.A
R
ev.
(0
6/0
3)
Su
pe
rse
de
s (1
2/9
8)
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comGUIDE SPECIFICATION
C.
2.01 EXTERIOR WALL PANELS &SYSTEMSA.
B.
2.
3.
a.
b.
c.
Finish Warranty:{Polyester: Five (5) years}{Acrylic Urethane: Five (5) years}{Kynar 500®: Twenty (20) years}{Kynar 500® Metallic: Twenty (20)years}{Anodized: Twenty (20) years}
(Specifier Note: Select productparagraph below to suit projectrequirements. Add productattributes, performance character-istics, material standards anddescriptions as applicable. Use ofsuch phrases as “or equal” and “orapproved equal” may causeambiguity in the specifications.Such phrases require verifica-tion—procedural, legal, regulatory,and responsibility—for determin-ing equivalence of products.)
Manufacturer:Citadel Architectural Products, Inc3131-A North Franklin RoadIndianapolis, Indiana 46226phone: (317) 894-9400
(800) 446-8828fax: (317) 894-6333
(800) [email protected]
SinoCore® - PrefinishedArchitectural Panels1. Panel Composition:
Face Skin:{.010” prefinished texturedaluminum to matchArchitect’s color selection.}{.024” (minimum) prefinishedsmooth aluminum to matchArchitect’s color selection.}
Core:4mm high densitypolypropylene
Back Skin:{.010” primed smoothaluminum backer}{.024” primed smoothaluminum backer}
D.
E.
1.07 DELIVERY, STORAGE ANDHANDLINGA.
B.
C.
D.
1.08 WARRANTYA.
B.
Manufacturer’s Literature: Two (2)copies of manufacturer’s literaturefor panel material.
Test Reports: Two (2) copies ofthird party test reports on testingrequired in Section 1.03.
(Specifier Note: Article belowshould include special and uniquerequirements. Coordinate articlebelow with Division 1 ProductRequirements Section.)
General: Comply with Division 1Product Requirements Section.
Delivery: Package all panels forprotection against transportationdamage in accordance withmanufacturer’s requirements.
Storage: Store all materials inaccordance with manufacturer’sinstallation instructions. Stackmaterials on pallets or platforms,covered with suitable ventilatedcovering. Do not store panelswhere accumulation of water mayoccur or in contact with othermaterials that might causestaining, denting or other damage.
Handling: All materials should behandled in a manner to preventdamage to the product in accor-dance with manufacturer’sinstallation instructions.
(Specifier Note: Coordinate articlebelow with Condition of theContract and with Division 1Closeout Submittals [Warranty]Section.)
Manufacturer’s Warranty: Furnishpanel manufacturer’s standardlimited warranty documentexecuted by an authorizedcompany official. Manufacturer’swarranty is in addition to and not alimitation of other rights Ownermay have under the ContractDocuments.
Panel Lamination Warranty: Five(5) years commencing on Date ofSubstantial Completion.
PART 2: PRODUCTS
2.02 SUBSTITUTIONSA.
B.
C.
D.
2.03 FINISHA.
B.
(Specifier Note: Revise articlebelow to suit project requirements.If substitutions are permitted, edittext below. Add text to refer toDivision 1 Project Requirements,Product Substitutions ProceduresSection.)
Acceptable Alternatives: Panels ofsimilar composition providingmanufacturer has a minimum often (10) years experience.
The materials and productsspecified in this section establisha standard of required function,dimension, appearance, andquality to be met by any proposedsubstitution.
No substitution will be consideredunless written request for approvalhas been submitted by the bidderand has been received by theArchitect ten (10) days prior to thedate for receipt of bids.
Each request shall include thename of the materials and acomplete description of theproposed material, including testperformance and any otherinformation necessary forevaluation.
Exposed Finish:{Polyester}{Acrylic Urethane}{Kynar 500®}{Kynar 500® Metallic}{Anodized}
Color: As selected by the Architectfrom panel manufacturer’s ColorSelection Guide.
a.
b.
c.
Panel Tolerances:
Attachment System:{One piece extruded aluminummoldings}{Two piece extruded aluminummoldings}
Thickness: ±1/32”
Length & Width: +0, -1/8”
Squareness: 1/64” per linealfoot
Citadel Architectural Products, Inc. SinoCore®
Call (800) 446-8828 or visit www.citadelap.com GUIDE SPECIFICATION
2.04 ACCESSORIESA.
B.
3.01 EXAMINATIONA.
B.
C.
Fasteners and moldings asrequired for panel system’s designby panel system manufacturer.Fastener shall be coated orstainless steel.
Weather Seals: Shall be Tremco®
Spectrem® 2, applied per thesealant manufacturer’s guidelinesand in accordance with the panelmanufacturer’s installationinstructions.
(Specifier Note: Revise articlebelow to suit project requirementsand specifier’s practice.)
Examine and verify substratesurfaces to receive compositemetal panel system and associ-ated work and condition whichwork will be installed.
Maximum deviation from verticaland horizontal alignment ofsubstrate shall be no more than1/4” in 20’-0”.
Do not proceed with work untilunsatisfactory conditions havebeen corrected in a manneracceptable to installer. Starting
PART 3: EXECUTION
3.02 PREPARATIONA.
B.
C.
D.
3.03 INSTALLATIONA.
B.
C.
work within a particular area willbe construed as installer’sacceptance of surface conditions.
Comply with manufacturer’sproduct data including producttechnical bulletins, productcatalog installation instructions,and product carton instructions.
Surfaces to receive panels shallbe even, smooth, sound, clean,and free from defects detrimentalto panel installation.
Field measure and verify dimen-sions as required.
Protect adjacent areas or surfacesfrom damage as a result of thework of this section.
(Specifier Note: Coordinate articlebelow with panel manufacturer’srecommended installation details.)
Sheathing and water resistantmembrane (if specified) by others.
Erect panels level and true tointended plane.
Maximum deviation from verticaland horizontal alignment oferected panel system shall be nomore than 1/4” in 20’-0”.
D.
E.
F.
3.04 CLEANINGA.
B.
END OF SECTION
Maximum deviation in panelflatness shall be 0.8% of theassembled units.
Conform to panel manufacturer’sinstallation instructions forattachment systems.
Weather seal all joints as requiredusing methods and materials asrecommended by the panelmanufacturer’s installationinstructions.
(Specifier Note: Coordinate articlebelow with Division 1 ExecutionRequirements, Cleaning Section.)
Remove temporary coverings andprotection to adjacent work areas.Repair or replace damagedinstalled products. Clean installedproducts in accordance withmanufacturer’s instructions priorto Owner’s acceptance.
Remove and legally dispose ofconstruction debris from projectsite.
Citadel Architectural Products, Inc.SinoCore®
Call (800) 446-8828 or visit www.citadelap.comGUIDE SPECIFICATION
SAMPLE
SINOCORE® PRODUCT WARRANTY
Citadel Architectural Products, Inc., 3131-A North Franklin Road, Indianapolis, Indiana 46226
©2003 Citadel Architectural Products, Inc. SinoCore® is a registered trademark of Citadel Architectural Products, Inc.Printed In The U.S.A. Form # 7.02.WR1.A Rev. (06/03) Supersedes (12/98)
(POLYESTER FINISH OR EQUIVALENT)
PROJECT:
LOCATION:
DATE:
Citadel warrants that: (a) at the time the Panels are delivered to theabove-described Project Site (the “Delivery Date”), the Panels will meetCitadel’s standard specifications then in effect; (b) the Panels will notdelaminate for a period of five (5) years from the Delivery Date; (c) theexterior painted finish of the Panels will not have a Chalk Rating of lessthan 6 or a Fade Differential of greater than 8E units (Hunter Color Dif-ference) for a period of five (5) years from the Delivery Date; and (d) thefinish of the Panels will not check, peel, lose adhesion or fracture (otherthan minute fractures which may develop due to fabrication and whichare acceptable by industry standards on the Delivery Date) for a periodof five (5) years from the Delivery Date.
For purposes of this Warranty: (a) “Chalk Rating” means the ratingcalculated by using the Method of Evaluating Degree of Chalking of Ex-terior Paint (per ATSM D4214-98); and (b) “Fade Differential” meansthe difference between the color value as measured on exposed paintedsurfaces that have been cleaned of external deposits and chalk and thecorresponding color value measured on the original unexposed paintedsurfaces; and (c) a Panel has a “Defect” and is “Defective” if it does notconform to this Warranty. Unequal fading or finish color changes result-ing from unequal exposure of surfaces to the sun or other exterior ele-ments or conditions are not Defects.
THIS WARRANTY DOES NOT COVER DEFECTS CAUSED BY:Exposure to smoke, fire, radiation, salt spray, chemicals, harmful or for-eign substances in the atmosphere, including but not limited to organicsolvents, concentrated detergents, wetting agents or sulfur dioxide emis-sion levels above those deemed safe by the U.S. Environmental Protec-tion Agency.
Negligence; improper maintenance; abuse; impact or other physical force,whether prior or subsequent to installation; normal wear and tear andweathering; fire, lightning, tornadoes, or other acts of God.
Defective or damaged fasteners, extrusions, brackets or fabricated ap-plications attached to or used in connection with installation of the Pan-els, or Defects in the Panels caused by such fasteners, extrusions, brack-ets or fabricated applications.
Failure to adequately seal edges and joints of the Panels or to apply anapproved sealant in its proper amount in accordance with Citadel’sSinoCore® Installation Guide.
Improper installation or sizing of the Panels, including moisture intru-sion, water and air leakage as a result of improper installation or sizing.
Damage incurred after the Delivery Date during storage, handling, in-stallation or maintenance of any of the Panels.
This Warranty is given by Citadel Architectural Products, Inc. (“Citadel”) to the initial owner and subsequent owners (“Owner”) of the structure onwhich SinoCore® panels (individually, a “Panel” and collectively, the “Panels”) are first installed.
DISCLAIMER OF WARRANTIES:THIS WARRANTY IS THE EXCLUSIVE WARRANTY GIVEN BY CITA-DEL FOR THE PANELS. CITADEL DISCLAIMS ALL OTHER WARRAN-TIES, WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDINGANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FIT-NESS FOR A PARTICULAR PURPOSE AND ANY IMPLIED WARRAN-TIES ARISING FROM A COURSE OF DEALING OR USAGE OF TRADE.THIS WARRANTY SUPERSEDES ALL OTHER WARRANTIES, IN-CLUDING ANY WARRANTIES BASED ON ORAL REPRESENTATIONS.
OWNER’S REMEDIES:For this Warranty to be valid, Owner must complete and return Citadel’sProduct Warranty Request Form within thirty (30) days of completion ofinstallation of the Panels at the above-described Project Site and shalldocument in writing its maintenance and cleaning of the Panels, andprovide such documentation to Citadel upon request. To make a claimunder this Warranty, Owner must send a written description of any claimedDefect (the “Claimed Defect”) to Citadel in writing at its address shownbelow within thirty (30) days of discovery of the Claimed Defect. Uponthe request of Citadel, Owner shall permit Citadel reasonable time toinspect Panels for which notice of a Claimed Defect has been givenprior to any removal, repair or replacement of the Panels. Any failure ofOwner to notify Citadel of a Claimed Defect or to afford Citadel a rea-sonable opportunity to inspect the Claimed Defect prior to taking anyremedial measures (including removal, repair or replacement) shall ren-der this Warranty void in its entirety and the Claimed Defect shall not becovered by this Warranty. If the Claimed Defect is a Defect covered bythis Warranty, Citadel, at its option, will do one of the following within areasonable period of time: (1) refinish or repair the Defective Panel;(2) furnish a conforming Panel to replace the Defective Panel; or (3) re-fund a prorated portion of the price paid to Citadel for the Defective Panel.In determining the amount of any refund to be paid by Citadel for a De-fective Panel, the original price paid to Citadel for such Defective Panelshall be reduced by 20% for each full year which has passed since theDelivery Date for delamination Defects covered by this Warranty and20% for each full year which has passed since the Delivery Date for allother Defects covered by this Warranty. Owner shall bear all costs ofremoval and disposal of Defective Panels and installation of all replace-ment Panels provided by Citadel.
THE REMEDIES SET FORTH HEREIN SHALL BE THE EXCLUSIVEAND SOLE REMEDIES OF OWNER FOR BREACH OF THIS WAR-RANTY AND FOR DEFECTS COVERED BY THIS WARRANTY.
EXCLUSION OF CONSEQUENTIAL AND OTHER DAMAGES:IN NO EVENT SHALL CITADEL BE LIABLE FOR ANY INCIDENTAL,INDIRECT OR CONSEQUENTIAL DAMAGES, WHETHER RESULTINGFROM THE USE, MISUSE OR INABILITY TO USE OR INSTALL THEPANELS OR FROM DEFECTS IN THE PANELS.
SAMPLE
SINOCORE® PRODUCT WARRANTY
Citadel Architectural Products, Inc., 3131-A North Franklin Road, Indianapolis, Indiana 46226
©2003 Citadel Architectural Products, Inc. SinoCore® is a registered trademark of Citadel Architectural Products, Inc.Printed In The U.S.A. Form # 7.02.WR2.A Rev. (06/03) Supersedes (12/98)
(KYNAR 500® & ANODIZED FINISHES)
PROJECT:
LOCATION:
DATE:
Citadel warrants that: (a) at the time the Panels are delivered to theabove-described Project Site (the “Delivery Date”), the Panels will meetCitadel’s standard specifications then in effect; (b) the Panels will notdelaminate for a period of five (5) years from the Delivery Date; (c) theexterior painted finish of the Panels will not have a Chalk Rating of lessthan 8 or a Fade Differential of greater than 5E units (Hunter Color Dif-ference) for a period of twenty (20) years from the Delivery Date; and (d)the finish of the Panels (either painted or anodized) will not check, peel,lose adhesion or fracture (other than minute fractures which may de-velop due to fabrication and which are acceptable by industry standardson the Delivery Date) for a period of twenty (20) years from the DeliveryDate.
For purposes of this Warranty: (a) “Chalk Rating” means the ratingcalculated by using the Method of Evaluating Degree of Chalking of Ex-terior Paint (per ATSM D4214-98); and (b) “Fade Differential” meansthe difference between the color value as measured on exposed paintedsurfaces that have been cleaned of external deposits and chalk and thecorresponding color value measured on the original unexposed paintedsurfaces; and (c) a Panel has a “Defect” and is “Defective” if it does notconform to this Warranty. Unequal fading or finish color changes result-ing from unequal exposure of surfaces to the sun or other exterior ele-ments or conditions and gradual color changes in anodized Panel finishfrom normal weathering are not Defects.
THIS WARRANTY DOES NOT COVER DEFECTS CAUSED BY:Exposure to smoke, fire, radiation, salt spray, chemicals, harmful or for-eign substances in the atmosphere, including but not limited to organicsolvents, concentrated detergents, wetting agents or sulfur dioxide emis-sion levels above those deemed safe by the U.S. Environmental Protec-tion Agency.
Negligence; improper maintenance; abuse; impact or other physical force,whether prior or subsequent to installation; normal wear and tear andweathering; fire, lightning, tornadoes, or other acts of God.
Failure of Owner to clean anodized Panel finish at least once a year, ora failure of Owner to perform all maintenance and cleaning in accor-dance with AAMA 610.1, Voluntary Guide Specification for Cleaning andMaintenance of Painted Aluminum Extrusions and Curtain Wall Panels.
Defective or damaged fasteners, extrusions, brackets or fabricated ap-plications attached to or used in connection with installation of the Pan-els, or Defects in the Panels caused by such fasteners, extrusions, brack-ets or fabricated applications.
Failure to adequately seal edges and joints of the Panels or to apply anapproved sealant in its proper amount in accordance with Citadel’sSinoCore® Installation Guide.
Improper installation or sizing of the Panels, including moisture intru-sion, water and air leakage as a result of improper installation or sizing.
Damage incurred after the Delivery Date during storage, handling, in-stallation or maintenance of any of the Panels.
This Warranty is given by Citadel Architectural Products, Inc. (“Citadel”) to the initial owner and subsequent owners (“Owner”) of the structure onwhich SinoCore® panels (individually, a “Panel” and collectively, the “Panels”) are first installed.
DISCLAIMER OF WARRANTIES:THIS WARRANTY IS THE EXCLUSIVE WARRANTY GIVEN BY CITA-DEL FOR THE PANELS. CITADEL DISCLAIMS ALL OTHER WARRAN-TIES, WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDINGANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FIT-NESS FOR A PARTICULAR PURPOSE AND ANY IMPLIED WARRAN-TIES ARISING FROM A COURSE OF DEALING OR USAGE OF TRADE.THIS WARRANTY SUPERSEDES ALL OTHER WARRANTIES, IN-CLUDING ANY WARRANTIES BASED ON ORAL REPRESENTATIONS.
OWNER’S REMEDIES:For this Warranty to be valid, Owner must complete and return Citadel’sProduct Warranty Request Form within thirty (30) days of completion ofinstallation of the Panels at the above-described Project Site and shalldocument in writing its maintenance and cleaning of the Panels, andprovide such documentation to Citadel upon request. To make a claimunder this Warranty, Owner must send a written description of any claimedDefect (the “Claimed Defect”) to Citadel in writing at its address shownbelow within thirty (30) days of discovery of the Claimed Defect. Uponthe request of Citadel, Owner shall permit Citadel reasonable time toinspect Panels for which notice of a Claimed Defect has been givenprior to any removal, repair or replacement of the Panels. Any failure ofOwner to notify Citadel of a Claimed Defect or to afford Citadel a rea-sonable opportunity to inspect the Claimed Defect prior to taking anyremedial measures (including removal, repair or replacement) shall ren-der this Warranty void in its entirety and the Claimed Defect shall not becovered by this Warranty. If the Claimed Defect is a Defect covered bythis Warranty, Citadel, at its option, will do one of the following within areasonable period of time: (1) refinish or repair the Defective Panel;(2) furnish a conforming Panel to replace the Defective Panel; or (3) re-fund a prorated portion of the price paid to Citadel for the Defective Panel.In determining the amount of any refund to be paid by Citadel for a De-fective Panel, the original price paid to Citadel for such Defective Panelshall be reduced by 20% for each full year which has passed since theDelivery Date for delamination Defects covered by this Warranty and5% for each full year which has passed since the Delivery Date for allother Defects covered by this Warranty. Owner shall bear all costs ofremoval and disposal of Defective Panels and installation of all replace-ment Panels provided by Citadel.
THE REMEDIES SET FORTH HEREIN SHALL BE THE EXCLUSIVEAND SOLE REMEDIES OF OWNER FOR BREACH OF THIS WAR-RANTY AND FOR DEFECTS COVERED BY THIS WARRANTY.
EXCLUSION OF CONSEQUENTIAL AND OTHER DAMAGES:IN NO EVENT SHALL CITADEL BE LIABLE FOR ANY INCIDENTAL,INDIRECT OR CONSEQUENTIAL DAMAGES, WHETHER RESULTINGFROM THE USE, MISUSE OR INABILITY TO USE OR INSTALL THEPANELS OR FROM DEFECTS IN THE PANELS.
Citadel Architectural Products, Inc.3131-A North Franklin RoadIndianapolis, Indiana 46226phone: (317) 894-9400
(800) 446-8828fax: (317) 894-6333
(800) [email protected]
©2006 Citadel Architectural Products, Inc. All Rights Reserved.An ISO 9001:2000 Registered Company.
Panel 15®, SinoCore®, Panel 20®, Envelope 2000®, GlazeGuard®, CleanCote®, BioWall® and Xylem® areregistered trademarks of Citadel Architectural Products, Inc. ProCore™, Premier™, Guardian™ andSentinel™ are trademarks of Citadel Architectural Products, Inc.