Product Innovation ReportHow Corrosion on the Negative Battery Terminal Destroys ECIMs
Test-proven Field Retrofit Solution Offered
27 May 2014
Hood Tech Proprietary 5/27/2014
Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered
![Page 2: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and](https://reader036.vdocuments.site/reader036/viewer/2022081409/6087dca5e9844914e91e3139/html5/thumbnails/2.jpg)
Applicability
• Mark 4 Commercial Launcher• HTL4.1 (STUAS Launcher)
Hood Tech Proprietary 5/23/2014
Negative Battery Lead Corrosion Destroys ECIMs; Field Retrofit Solution
Offered
2
![Page 3: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and](https://reader036.vdocuments.site/reader036/viewer/2022081409/6087dca5e9844914e91e3139/html5/thumbnails/3.jpg)
3
Problem Report• NSW (T3) reports melted blue wires inside the ECIM and
uncommanded system shut-down following Compressor start attempt.
• Replacing ECIM resulted in melted ECIM wires on the new ECIM.
• Upgrading compressor start circuit at compressor did not help; a third ECIM was destroyed with the same symptoms as the first two.
• The site is located near salt water. Battery terminal corrosion and evidence of arcing reported from the site, which confirms the root cause analysis.
Hood Tech Proprietary 5/27/2014
Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered
![Page 4: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and](https://reader036.vdocuments.site/reader036/viewer/2022081409/6087dca5e9844914e91e3139/html5/thumbnails/4.jpg)
Field Failure (photo 1 of 5)
4Hood Tech Proprietary 5/27/2014
Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered
![Page 5: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and](https://reader036.vdocuments.site/reader036/viewer/2022081409/6087dca5e9844914e91e3139/html5/thumbnails/5.jpg)
Field Failure (photo 2 of 5)
5Hood Tech Proprietary 5/27/2014
Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered
![Page 6: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and](https://reader036.vdocuments.site/reader036/viewer/2022081409/6087dca5e9844914e91e3139/html5/thumbnails/6.jpg)
Field Failure (photo 3 of 5)
6Hood Tech Proprietary 5/27/2014
Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered
![Page 7: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and](https://reader036.vdocuments.site/reader036/viewer/2022081409/6087dca5e9844914e91e3139/html5/thumbnails/7.jpg)
Field Failure (photo 4 of 5)
7Hood Tech Proprietary 5/27/2014
Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered
![Page 8: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and](https://reader036.vdocuments.site/reader036/viewer/2022081409/6087dca5e9844914e91e3139/html5/thumbnails/8.jpg)
Field Failure (photo 5 of 5)
8Hood Tech Proprietary 5/27/2014
Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered
![Page 9: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and](https://reader036.vdocuments.site/reader036/viewer/2022081409/6087dca5e9844914e91e3139/html5/thumbnails/9.jpg)
9
Root cause:•Corrosion build-up prevents compressor start current from returning directly to negative battery terminal. Instead, it passes first through ECIM, returning via trailer chassis and generator negative battery leads.
•Overloaded blue wire shorts with leads carrying +12VDC or +24VDC inside ECIM, which causes internal voltage droop and system shut-down.
Hood Tech Proprietary 5/27/2014
Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered
![Page 10: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and](https://reader036.vdocuments.site/reader036/viewer/2022081409/6087dca5e9844914e91e3139/html5/thumbnails/10.jpg)
Hood Tech Re-enactmentCompressor Start Commanded with Wiring Fault (simulated corrosion) as shown in Previous Slide.
>100 amps observed through clamp-on ammeter.
10Hood Tech Proprietary 5/27/2014
Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered
![Page 11: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and](https://reader036.vdocuments.site/reader036/viewer/2022081409/6087dca5e9844914e91e3139/html5/thumbnails/11.jpg)
Compare Damagewith Fielded Launcher. Image taken after 5-seconds of “Compressor-Start” Commanded
11
+24V (orange)Shorted to-12V (blue), causing systemto shut down
Hood Tech Proprietary 5/27/2014
Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered
![Page 12: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and](https://reader036.vdocuments.site/reader036/viewer/2022081409/6087dca5e9844914e91e3139/html5/thumbnails/12.jpg)
Compare Damage
12Hood Tech Proprietary 5/27/2014
Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered
![Page 13: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and](https://reader036.vdocuments.site/reader036/viewer/2022081409/6087dca5e9844914e91e3139/html5/thumbnails/13.jpg)
13
Test-proven RemedyArrange negative battery leads as shown and add a 10A fuse to protect
ECIM from large start currents demanded by compressor starter.
Note: HTL4.2 ECIMHas introduced this fuse protection inside the ECIM
Hood Tech Proprietary 5/27/2014
Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution
Offered
![Page 14: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and](https://reader036.vdocuments.site/reader036/viewer/2022081409/6087dca5e9844914e91e3139/html5/thumbnails/14.jpg)
Retrofit Kit
Hood Tech Proprietary 5/27/2014
Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered
14
![Page 15: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and](https://reader036.vdocuments.site/reader036/viewer/2022081409/6087dca5e9844914e91e3139/html5/thumbnails/15.jpg)
As Installed
Hood Tech Proprietary 5/27/2014
Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered
Hood Tech Proprietary 15
Stainless steel clamping bolt grounds negative battery terminal to trailer chassis
Isolated and fuse-protected post terminates ECIM –battery lead
ECIM -battery lead(Not included)