product catalogue - system controls & switchgears dvs miniprok... · 2017. 1. 12. · product...
TRANSCRIPT
P R O D U C T C ATA L O G U E
These relays are suitable for monitoring
Incoming 3 -Phase Supp ly f rom Ma ins
( E l e c t r i c i t y d i s t r i b u t i o n l i n e ) . B e i n g
independent of load, they can be used for any
HP/KW rating of load.
MODELS
FEATURES
Fixed/Adjustable Unbalance Settings
Fixed/Adjustable Under Voltage/Over Voltage Settings
Fixed/Adjustable Trip Delays
Built in or External Power Supply
Resetting Auto / Manual / Remote
Output Contacts: 1 CO or 2 CO
Choice of Enclosures (DIN-Rail,Plugin,Surface Mounting)
Models with Micro Controller based design
Use of SMD Technology
User friendly LED indications
PROTECTIONS/FUNCTIONS
Phase Failure (Phase Loss/Single Phasing)
Phase Sequence Reversal,
Voltage Unbalance,
Under Voltage,
Over Voltage
Dry Run
Ordering Instructions
Product Family Name
Model Name
System Supply Voltage
& Frequency
Aux. Supply / Control
Supply Voltage
√
√
√
√
PHASE FAILURERELAYS
1
PDVSP M1
PDVSP M2
PDVMR7 C1
PD PFS1
PDHLV M2
PDALV M2
PDVMR M2
PDHLS1 M1
PDVMR1 M2
PDVMR2 M2
PDVMR3 C2
1 2 3 4 5 6
7 8 9 10 11 12
2
PHASE FAILURE RELAYS
Product
Phase Failure,
Unbalance, Phase
Sequence,
Auto Reset,
Fixed Unbalance Setting,
1 CO output Relay
Phase Failure,
Unbalance,
Phase Sequence,
Auto/Manual/Remote
Reset, Adjustable
Unbalance setting,
2 CO output relay
Phase Sequence,
Auto Reset,
1 CO output relay
Phase Sequence,
Auto Reset,
1 CO output relay
Supply Voltage
System
Auxiliary
Output Contacts
Trip Setting (Volts)
Phase Sequence
Phase Unbalance
Trip Time Delay
On Phase Failure/Unbalance
For level sensing
Resetting Mode
Weight
Dimensions (mm)
Overall (L x W x D)
Mounting (L x W)
100-120/220-240/380-440V AC ±20%
50/60Hz
100-120/220-240/380-440V AC ±20%
1CO
Yes
40V ± 6V (fixed)
3.5 Sec. ± 1.5 Sec
N.A.
Auto
224 gms.
75.5 x 30 x 117
68 centre to centre/35 mm rail Mounting
Wherever not specified
Contact Rating:
5A @ 230V AC
(resistive)
* Available on request.
100-120/220-240/380-440V AC ± 20%
50/60Hz
100-120/220-240/380-440V AC ± 20%
2 CO
30V to 70V ± 6V (adjustable)
3.5 Sec. ±1.5 Sec.
N.A.
Auto/Manual / Remote
285 gms.
76 x 56.5 x 117
67 x 46 /35 mm rail Mounting
380 - 440 VAC. ± 20%. 3PH-3 Wire
Built-In from 3-Phase
1 CO
Yes
Instant
N.A.
Auto Reset
70 gms. (Approx.)
91 x 29 x 65 (Approx.)
35 mm rail Mounting
110/220/ 380/415 VAC ± 10%,
50160 Hz
Built-in
1 CO
Yes
Instant
N.A.
Auto Reset
90 gms.
49.5x395x68
8 Pin Plug - In
Yes
-
13
15
13
14
16
17
16
18
AuxSupply
3 Ph
R Y B R B Y R B R Y B
Td : 2-5 Sec.
Phase Fail
R
Y
B
2
14
8
1
13
7
3
15
9
AUX.SUPPLY
4
16
10
5
17
11
6
18
12
N/V
OFF
ON
DOL STARTER
L1
L2
L3 M
M
11
11 12
3 PhR Y B R B Y R Y B
107
1 8
3 PhR Y B R B Y R Y B
8
1
2
34 5
6
7
8
M
8 7
NO
1 8
N C
R
Y
B
Bottom view
Model PDVSP M1 PDVSP M2 PDVMR7 C1 PDPF S1
R
Y
B
2
14
8
1
13
7
3
15
9
AUX.SUPPLY
N/V
OFF
ON
DOL STARTER
L1
L2
L3 M
13 14
13 15
3 Ph
AuxSupply
R Y B R B Y R B R Y B
Td : 2-5 Sec.
Phase Fail
PDVSP M1
Phase Failure Relay Phase Failure Relay Phase Sequence Relay Phase Failure Relay
PDVSP M2
PDVMR7 C1
PD PFS1
Phase Failure, Unbalance,
Phase Sequence, Under Voltage,
Over Voltage, Manual reset,
Fixed Unbalance setting,
Adjustable UV/OV settings,
2 CO Output relay
Phase Failure, Unbalance,
Phase Sequence, Under Voltage,
Over Voltage Auto Reset,
Fixed Unbalance setting,
Adjustable UV/OV settings,
2 CO Output relay
Phase Failure, Unbalance,
Phase Sequence, Under Voltage,
Over Voltage, Auto Reset,
Fixed Unbalance setting,
Adjustable UV/OV settings,
2 CO Output relay
PHASE FAILURE RELAYS
Supply Voltage
System
Auxiliary
Output Contacts
Trip Setting (Volts)
Phase Sequence
Phase Unbalance
For 380-440V AC
For 220-240V AC
For 100-120V AC
Over For 380-440V AC
For 220-240V AC
For 100-120V AC
Trip Time Delay
On Phase Failure
On UV/OV
Resetting Mode
Weight
Dimensions (mm)
Overall (L x W x D)
Mounting (L x W)
110/240/380/415/440V AC± 20% 50/60Hz
11 OV(Fixed) or (220-230-240) or (380-415-440) V AC± 20%
2 CO
Yes
40V± 6V (fixed)
80% to 95% (adjustable)
105% to 120% (adjustable)
3.5 Sec.±1.5 Sec.
Less than 2 Sec. for OV & 2-5 Sec. for UV
Manual/Remote
295 gms.
76x56.5x 117
67 x 46 /35 mm rail Mounting
110/240/380/415/440V AC±20% 50/60Hz
110V (Fixed) or (220-230-240) or (380415-440) V AC±20% selectable
2 CO
Yes
40V±6V (fixed)
80% to 95% (adjustable)
105% to 120% (adjustable)
3.5 Sec.± 1.5 Sec.
Less than 2 Sec.
Auto Reset
290 gms.
76x56.5x117
110/220/230/240/380/415/440V AC± 20% 50/60Hz
110/220/230/240/380/415/440V AC±20%
2 CO
Yes
94V±6V (fixed)
80% to 95% (adjustable)
105% to 120% (adjustable)
3.5 Sec.±1.5 Sec.
Less than 2 Sec.
Auto Reset
290 gms.
76x56.5x117
67 x 46 /35 mm rail Mounting
Voltage
Voltage Under
67 x 46 /35 mm rail Mounting
Product
.Wherever not specified
Contact Rating:
5A@230 V AC
(resistive)
.*CE marked products
available on request.
3
3 Ph
AuxSupply
R Y B R B R Y R Y B B
Unbal./Phase Fail
Td : 2-5 Sec.
UVOV
1613 1714
1815 1613
R
Y
B
N/VOFF ON
DOL STARTER
L1
L2
L3MOTOR
2
14
8
1
13
7
3
15
9
AUX.SUPPLY
4
16
10
5
17
11
6
18
12
R
Y
B
N/VOFF ON
DOL STARTER
L1
L2
L3MOTOR
2
14
8
1
13
7
3
15
9
AUX.SUPPLY
4
16
10
5
17
11
6
18
12
3 Ph
AuxSupply
R Y B R B R Y R Y B B
Unbal./Phase Fail
Td : 2-5 Sec.
UVOV
1613 1714
1815 1613
3 Ph
AuxSupply
R Y B R B R Y R Y B B
Unbal./Phase Fail
Td : 2-5 Sec.
UVOV
1613 1714
1815 1613
R
Y
B
N/VOFF ON
DOL STARTER
L1
L2
L3MOTOR
2
14
8
1
13
7
3
15
9
AUX.SUPPLY
4
16
10
5
17
11
6
18
12
Model PDHLV M2 PDALV M2 PDVMR M2Phase Failure With UV/OV Relay Phase Failure With UV/OV Relay Phase Failure With UV/OV Relay
PDHLV M2
PDALV M2 PDVMR M2
Phase Failure, Unbalance,
Phase Sequence,
Under Voltage, Over Voltage,
Auto reset, Fixed Unbalance
Setting, Fixed UV/OV settings,
2 CO output relay
Suitable for 3Ø-3W system.
Microcontroller design,
SMD Technology,
Absolute values of UV/OV settings,
Phase Failure. Unbalance, Phase
Sequence, Under Voltage, Over Voltage,
AutofManual reset, Adjustable settings
for Unbalance. UV/OV and trip delays,
2 CO output relay
Suitable for 3Ø-4W system,
Microcontroller design,
SMD Technology,
Absolute values of UV/OV settings
Phase Failure, Unbalance, Phase
Sequence, under voltage, Over Voltage
Auto/Manual reset, Adjustable settings
for Unbalance, UV/OV and trip delays,
2 CO output relay
Microcontroller design,
SMD Technology,
Absolute values of UV/OV settings,
Phase Failure, Unbalance. Phase
Sequence, Under voltage, Over Voltage
Auto/Manual reset. Adjustable settings
for Unbalance. UV/OV and trip delays,
2 CO output relay
Supply Voltage
Auxiliary
Output Contacts
Trip Setting (Volts)
Phase Sequence
Phase Unbalance
Under
Voltage
For 380-440V AC
For 220-240V AC
For 100-120V AC
Over
Vdtage
For 380-440V AC
For 220-240V AC
For 100-120V AC
Trip Time Delay
On Phase Sequence
On SP/UV/OV
Resetting Mode
Weight
Dimensions (mm)
Overall (L x W x D)
Mounting (L x W)
100-110-120/220-230-240/380-415-440V AC
120% 48-63 Hz,
Built In Selectable by Front Knob
2CO
Yes
10% (fixed )
75% of system supply (Fixed)
120% of system supply (Fixed)
2-5 Sec. UB/SP
Less than 2 Sec.UV/OV,Instant RP
Auto
140 gms.
75.5x30x117
68 centre to centre/35 mm rail Mounting
100-120 / 220-240 / 380-440V AC -25%+20%
48-63Hz
Built In (from 3 Phases)
2CO
Yes
4%-20% [Variable]
285-425V AC [Variable]
165-225V AC [Variable]
75-115V AC [Variable]
400-520V AC [Variable]
230-290V AG [Variable]
105-145V AC [Variable]
Instant
1 To 10 Sec_ [Variable)
Auto/ Manual Reset (External NC Push Buttons)
192 gms.
76x56.5x117
67 x 46 /35 mm rail Mounting
100-120 / 220-240/380I-44OV AC -25%+20%
43-63 Hz
Built In (from 3 Phases)
2 CO
Yes
4%-20% [Variable]
165-245V AC [Variable]
95-135V AC [Variable]
45-65V AC [Variable]
230-310V AC [Variable]
130-170V AC [Variable]
60-80V AC [Variable]
Instant
1 To 10 Sec. [Variable]
Auto/ Manual Reset (External NC Push Buttons)
160 gms.
76x56.5x117
67 x 46 /35 mm rail Mounting
I 00-120 / 220-240 / 380--440V AC -25%+20%
48-63 Hz
Built In (from 3 Phases]
2 CO
Yes
4 % - 20 % [Variable]
285--425V AC [Variable]
165-225V AC [Variable]
75-115V AC [Variable]
400-520V AC [Variable]
230-290V AC [Variable]
105-145V AC [Variable]
Instant
1 To 10 Sec. [Variable]
Auto/ Manual Reset [Selectable]
115 gms (Approx.)
91 X35X64
35 mm Rail Mounting
" Wherever not specified
Contact Rating
5A @ 230 V AC
(resistive)
PHASE FAILURE RELAYS
4
Product
System
113
113 315
3 Ph
214
Td : 3.5 Sec.
UV
OV
Unbalance / Phase fail
R Y B R Y R B Y
L OA D
1613
1613 1815
3 Ph
1714
Td : 1-10 Sec.Td : 1-10 Sec.
UV
OV
Unbalance / Phase fail
R Y B R Y R B Y
L OA D
MANUAL
RESET PB
R
Y
B
1613
1613 1815
3 Ph N
1714
Td : 1-10 Sec.Td : 1-10 Sec.
UV
OV
Unbalance / Phase fail
R Y B R Y R B Y
L OA D
MANUAL
RESET PB
R
Y
B
N
3 Ph
Td : 1-10 Sec.Td : 1-10 Sec.
UV
OV
Unbalance / Phase fail
R Y B R Y R B Y
7 8 10 11
7 9 10 12
Model PDHLS1 M1 PDVMR1 M2 PDVMR2 M2 PDVMR3 C2Phase Failure With UV/OV Relay Phase Failure With UV/OV(3 -3W) Phase Failure With UV/OV(3 -4W) Phase Failure With UV/OV Relay
PDHLS1 M1
PDVMR1 M2 PDVMR2 M2
PDVMR3 C2
1 2 3 4 5 6
7 8 9 10 11 12
These relays are best suitable for monitoring
balanced or unbalanced supplies, either of
Single Phase, 3Phase 3Wire or 3Phase
4Wire loads powered by Generators, UPS,
Stabilizers, Inverters, or Mains (by Electricity
Boards / Utilities); in AMF Panels, PCCs,
Distribution boards and for power monitoring
of individual loads / motors / pumps.
Fixed/adjustable under/Over trip settings for parameters.
Fixed/adjustable trip delays and Power On delays
Built-in or external power supply
Resetting -Auto or Manual
Output contacts : 1 CO or 2 CO
Choice of enclosures (DIN-Rail)
Models with Micro-Controller based design
Use of SMD Technology
User-friendly LED indications
Under/Over Voltage,
Under/Over Current
MONITORINGRELAYS
FEATURES
PROTECTIONS/FUNCTIONS
Product Family Name
Model Name
System Supply Voltage
& Frequency
Aux. Supply/Control
Supply voltage
Current input (1A or 5A)
Ordering Instructions
√
√
√
√
√
MODELS
5
PDVCR1 M1
PDVCT M2
PDVCF M2
PDVCT1 M2
PDUVT M1
PDUVF M1
PDOCS M1
PDCT M1
Single Phase Under &
Over voltage, Auto Reset,
Adjustable Under / Over
voltage settings,
2 CO output relay
3-Phase 3-Wire Under& Over voltage
Auto/Manual Reset,
Adjustable Under/Over voltage settings,
adjustable trip delay & ON delay,
2 CO output relay
3-Phase 4-Wire Under & Over voltage
Auto/Manual Reset,
Adjustable Under/Over voltage settings,
adjustable trip delay & ON delay,
2 CO output relay
System Supply
Output Relay Contact
Trip Setting
Under Voltage
Over Voltage
Trip Time Delay
Power on Delay
Reset
Weight
Dimensions (mm)
Overall (L x W x D)
Mounting
" Wherever not specifiedContact Rating:5A @ 230 VAC(resistive)
220/ 230/240 VAC (+20%-30%), 50/60 Hz±3%
2 CO
75-95% [Variable] of set value
105-120% [Variable] of set value
2-5 Sec. (Fixed) (UV/OV)
Auto Reset
140 gms.
75.5x30x117
68 mm centre to centre/35 mm rail mounting
110/240/380/415/440 V AC +20%, -25% 50/60Hz
2 CO
75-95% [Variable] of set value
105-120% [Variable] of set value
1-10 Sec. (adjustable)
1-10 Sec. (adjustable)
Auto/Manual
291 gms.
76 x 56.5 x 117
67 x 46 /35 mm rail mounting
110/240/380/415/440 VAC +20%,-25% 50/6OHz
2 CO
75-95% [Variable] of set value
105-120% [Variable] of set value
1-10 Sec. (adjustable)
1-10 Sec. (adjustable)
Auto/Manual
285 gms.
76 x 56.5 x 117
67 x 46 /35 mm rail mounting
6
Product
113
113 315
214
1 Ph N
OV SET
UV SET
OV RESET
UV RESET
TD 2 to 5sec. TD
ON
N/V
OFF
2
14
8
1
13
7
3
15
9
L
N
LOAD
1613
1613 1815
1714
3 Ph
T on1 to 10sec.
OV SET
UV SET
OV RESET
UV RESET
TD1 to 10sec. TD
L
O
A
D
N/VON
OFF
R
Y
B
N
2
8
1
7
3
9
4
10
5
11
6
1413 15161718
12
A/M
LINK
L
O
A
D
N/VON
OFF
2
8
1
7
3
9
4
10
5
11
6
1413 15161718
12
A/M
LINK
R
Y
B
VOLTAGE MONITORING RELAYS
ModelPDVCR1 M1 PDVCT M2 PDVCF M2
1 Phase Voltage
Monitoring Relay
Voltage Monitoring
Relay,3 -3W
Voltage Monitoring
Relay,3 -4W
PDVCR1 M1
PDVCT M2 PDVCF M2
PDVCR1 M1
3-Phase 3-Wire and 3-Phase4-Wire (selectable) Under & OverVoltage, Microcontroller based design,Auto/Manual Reset,Adjustable underiover voltage settings,Absolute values for UV/OV, adjustabletrip delay & ON delay, 2 CO output relay(or selectable ICO for UV, 1CO for OV)Programming Mode,Failsafe-non-faiIsafe selectable
3-Phase 3-Wire Under
Auto Reset,
Adjustable Under Voltage settings,
adjustable trip delay & ON delay,
I CO output relay
3-Phase 4-Wire Under
Auto Reset,
Adjustable Under Voltage settings,
adjustable trip delay & ON delay,
1 CO output relay
System Supply
Output Relay Contact
Trip Setting
Under Voltage
Over Voltage
Trip Time Delay
Power on Delay
Reset
Weight
Dimensions (mm)
Overall (L x W x D)
Mounting
100-120/220-240/380-440 VAC-25% +20%, 48-63Hz
1 CO+1 CO/2CO
Ph Ph Setting:
For 380-440V AG
For 220-240V AC
For 100-120V AC
Ph N Setting:
For 380-440V AC
For 220-240V AC
For 100-120V AC
Ph Ph Setting:
For 380-440V AC
For 220-240V AC
For 100-120V AG
Ph N Setting:
For 380-440V AC
For 220-240V AC
For 100-120V AC
285-425V AC (Variable)
165-225V AC (Variable)
75-115V AC (Variable)
165-245V AC (Variable)
95-135V AC (Variable)
45-65V AC (Variable)
400-520V AC (Variable)
230-290V AC (Variable)
105-145V AC (Variable)
230-310 V AC (Variable)
130-170V AC (Variable)
60-80V AC (Variable)
1-10 Sec. (Variable) UV/OV/NF
1-10 Sec. (Variable)
Auto/ Manual Reset
160 gms (Approx.)
76 x 56.5 x 117
67 x 46 135 mm rail mounting
110/220/230/240/380/415/440 V AC +20%,-25% 50/60HZ
1CO
75-95% [Variable] of set value 75-95% [Variable] of set value
1-10 Sec_ (adjustable)
3.5 Sec.± 1.5 Sec. (Fixed)
Auto
224 gms.
75.5 x 30 x 117
68 centre to centre/35 mm rail Mounting
" Wherever not specified
Contact Rating:
5A @ 230 VAC
(resistive)
Product
110/220/230/240/380/415/440 V AC +20%,-25% 50/60HZ
1CO
1-10 Sec_ (adjustable)
3.5 Sec.± 1.5 Sec. (Fixed)
Auto
224 gms.
75.5 x 30 x 117
68 centre to centre/35 mm rail Mounting
7
2 3
8 9
14 15
L
O
A
D
OFF
ON
N/V
1
7
13
R
Y
B
R
Y
B
N
L
O
A
D
OFF
ON
N/V
1 2 3
7 8 9
13 14 15
Model PDVCT1 M2 PDUVT M1 PDUVF M1
VOLTAGE MONITORING RELAYS
Voltage Monitoring Relay Voltage Monitoring Relay Voltage Monitoring Relay
PDUVT M1
PDUVF M1
1613
1613 1815
1714
3 Ph N
T on1 to 10sec.
OV SET
UV SET
OV RESET
UV RESET
TD1 to 10sec. TD
N
L O A D
3 or 4 Wireselection link
PDVCT1 M2
Single phase over current, Auto reset,
Input 1A or 5 A through CT,
Adjustable over current trip settings,
Adjustable trip delay,
1 CO output relay
Current sensor suitable
for full, load motor current
of 1.25A, 2.5A, 5A, 10A,
To be used with
prok dvs relays only.
Supply Voltage
System
Auxiliary
Ext. Input
Output Contact
Trip Setting (Volts)
EF Trip Setting
Under Current
Over Current
Power On Delay
Trip Time Delay
Resetting
Weight
Dimensions (mm)
Overall (L x W x D)
110-120/220-240/380-440V Ac±20%,
12V DC/24/30V DC±10%
1 Amp/5 Amp (Secondary) CT or 250/ 500 mA
1CO
N.A.
50% -140% (adjustable) of CT sec
3.5 Sec.±1.5 Sec. (fixed)
1-10 Sec. (adjustable)
Auto
175 gms.
75.5 x 30 x 117
68 centre to centre/35 mm rail Mounting
220 gms.
75.5x30x117
68 centre to centre/35 mm rail Mounting
N.A.
" Wherever not specified
Contact Rating:
5A@23OVAC
(resistive)
Product
Mounting(Lx W)
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
-
8
Aux. Supply
OC SetPointOC Reset
T
ON2 to 5 sec. Td -
13
13
14
15
1 to 10 sec.
Current Input
2
14
8
1
13
7
3
15
9
N/V
DOL STARTER
OFFON
LOAD
L
N
AUX.SUPPLY
Selection Chart for PDCT M1
HP
<0.75
<1.75
<3
<6
KP
<0.5
<1.30
<2.25
<4.5
Amp
0.5-1.25
1-2.5
2-5
4-10
PDCT M1 Model
PDCT M1/1.25
PDCT M1/2.5
PDCT M1/5
PDCT M1/10
Model PDOCS M1 PDCT M1
CURRENT MONITORING RELAYS
1Phase Over Current Relay
PDOCS M1
These relays are useful for protection of
3-phase AC induction motors against various
hazards. With their unique advantages they
eliminate use of athermal/bimetal relay
for motor protection.Being current sensing,
they are to beselected according to motor
rating and areavailable for practically all
ranges of motors.These relays are ideally
suitable for Air-conditioning Compressor
motor protection,as also for motors in
machines, conveyors,cranes/hoists and lifts,
and for pumps.etc.
Fixed/adjustable unbalance settings
Fixed/adjustable settings for Under/Over Voltage and Over load
Fixed/adjustable trip delays
Resetting Auto or Manual
Output contacts : 1 CO or 2 CO
Choice of enclosures (DIN-Rail)
Models with Micro-Controller based design
Use of SMD Technology
User-friendly LED indicationsProduct Family Name
Model Name
System Supply Voltage &
frequency
Aux. Supply/Control supply
voltage
Motor/Pump rating (HP/KW)
& duty
Overload characteristics
required
Phase Failure (Phase Loss/Single Phasing),
Phase Sequence reversal,
Voltage Unbalance,
Under Voltage, Over Voltage
Overload Protection as per motor IDMTL characteristics
No-load/dry running
Over-current/locked rotor
FEATURES
PROTECTIONS/FUNCTIONS
MODELS
Ordering Instructions
MOTOR/PUMP
PROTECTION RELAYS
√
√
√
√
√
√
9
PDMPR M2
PDSPG M2
PDCT C2
Phase Failure, Unbalance, Phase
sequence and overloading
Auto/Manual Reset,
Adjustable current trip settings,
selectable characteristics,
1 CO/2CO output relay
Phase Failure, Unbalance,
Phase sequence,
Overloading & Dry running
Auto/Manual Reset,
Adjustable current trip settings,
selectable overload characteristics
1CO/2CO output relay
Current sensor suitable
for full load motor current
of 1.25A, 2.5A, 5A, 1OA,
20A, 40A & 80A
To be used with
prok dvs relays only.
Supply Voltage
System
Auxiliary
Output Relay Contact
Input
Trip Setting
Phase to phase unbalance
Under current (Dry running)
Overload
UV/OV
Trip Time Delay
On Phase Failure
For Overloading
UV/OV RP
Resetting
Dimensions (mm)
Overall (L x W x D)
Mounting (L x W)
Weight
100-120/220-240/380-440 V AC±20%
110/240/380/415V AC/DC/ 24V AC/DC±20%.50/60 Hz
1 CO (2 CO)
From (PDCT C2)
50% of motor Current ±10%
N.A.
Above 120% of set Current (IDMTL)
N.A.
5.5 Sec.±1.5 Sec.
As per selectable inverse time Characteristics
2 /5 Sec.(Selectable) 10 / 15 / 20 Sec. (optional)
N.A.
Auto /Manual / Remote
76x56.5x117
67 x 46 /35 mm rail Mounting
284 gms.
100-120/220-240/380-440 V AC±20%
110/240/380/415/440V AC/DC/24V AC/DC±20%, 50/60 Hz
1 CO (2 CO)
From (PDCT C2)
50% of motor Current
50%/75% of set current
Above 120% of set Current (IDMTL)
N.A.
5.5 Sec. ±1.5 Sec.
As per selectable inverse time Characteristics
NA.
Auto / Manual /Remote
76x56.5x117
67 x 46 /35 mm rail Mounting
280 gms.
N.A.
N.A
3-wire Terminals Output
N.A.
N.A.
N.A.
91 x35.5x60
35 mm Rail Mounting
150 gms.
" Wherever not specifiedContact Rating:5A @a 230 VAC(resistive)
Product
N.A.
N.A.
N.A.
N.A.
10
700 %600 %400 %
120 %100 %
10 %
0 %
MotorCurrent (%)
3 ph
O/L
Phase Fail
R Y B R B / / / / / / / / / / / / / / /
13
14
15
13
T1 T1As per IDMTL
200 %
T2 4 to 7 sec.
T1 = O/L
Trip DelayT2 = SP
Trip Delay
R
Y
B
AUX.SUPPLY
R B
PDCT C2
IN INOUT OUT
A/M Link
Link at 17-18 for2 or 5 Sec. IDMTL
curve selection
MOTOR/PUMP PROTECTION RELAYS
700 %600 %400 %
120 %100 %
10 %
0 %
MotorCurrent (%)
3 ph
O/L
Phase Fail
R Y B R B / / / / / / / / / / / / / / /
13
14
15
13
T1 T1
T2
As per IDMTL
200 %
T2 4 to 7 sec.
T1 = O/L
Trip DelayT2 = SP / DR Trip Delay
R
Y
B
AUX.SUPPLY
R BIN INOUT OUT
A/M Link
Dry run Link
Selection Chart for PDCT C2
HP KW Amp PDCT C2 Model
<0.75 <0.5 0.5-1.25 PDCT C2/1.25
<1.75 <1.30 1-2.5 PDCT C2/2.5
<3 <2.25 2-5 PDCT C2/5
<6 <4.5 4-10 PDCT C2/10
<12.5 <9.4 8-20 PDCT C2/20
<30 <22.5 16-20 PDCT C2/40
<60 <45 32-80 PDCT C2/80
ModelPDMPR M2 PDSPG M2 PDCT C2
PDMPR M2
PDSPG M2
PDCT C2
Overload Protection Relay
With Phase Failure
Dry Run & Overload Protection Relay
With Phase FailureCurrent Sensor
2 /5 Sec.(Selectable) 10 / 15 / 20 Sec. (optional)
√
These are suitable for conductive liquids
like water and for non-conductive liquids
like Diesel/Oil. Models for either one level
monitoring or two level monitoring.
Ordering Instructions
Product Family Name
Model Name
System Supply Voltage
Aux_ Supply/Control
supply voltage
Type of liquid & its
specifications
Can be used for potable water, water with impurities and for diesel/oil
Cable size & length no restriction for water level monitoring
Suitable for variety of electrodes
Optical sensing for diesel/oil level monitoring
Choice of enclosures (DIN-Rail)
Level monitoring of conductive and non-conductive liquids
One level or two level monitoring
One tank or two tank level monitoring
√
√
√
√
FEATURES
FUNCTIONS
MODELS
11
LIQUID LEVEL
CONTROLLERS
PDWLC M1
Single tank - 2 level control relay, suitable for conductive
liquids, sensitivity adjustment,
1 CO output relay.
Also can be used as moisture control relay.
Auxiliary Supply
Output Contacts
Input Sensors
Sensitivity
Trip Time Delay
Weight
Unit
Sensor (each)
Dimensions (mm)
Overall (L x W x D)
Mounting (L x W)
Sensor (mm)
Overall
24 VAC/DC/100-120/220-240/380-440 V AC ± 10%, 50 / 60 Hz
1 CO
3 Electrodes
1 K Ω- 200 KΩ (adjustable)
Less than 1 Sec.
217 gms.
50 gms.
75.5 x 30 x 117
68 mm centre to centre /35 mm rail mounting
24 (Dia) x 76 (L)
Wherever not specified
Contact Rating:
5A @ 230 V AC
(resistive)
Unit
12
Product
LEVEL CONTROLLERS-CONDUCTIVE LIQUIDS
p1p2
p3
p1p2
p3
p1p2
p3
p1p2
p3
p1p2
p3
Aux Supply
Suction (Source)ank Water Level
13
14
15
13
MOTOR
2
14
8
1
13
7
3
15
9
R
Y
B
N/VOFF
ONDOL STARTER
M1
M2
M3
AUX.SUPPLY
P1P2
P3
Link for Autooperation
Moisture control relay connection: Short 1 & 3 terminals. Connect sensor wires at 1 & 2 terminals.
Model PDWLC M1Water Level Control Relay Two Level Single Tank
PDWLC M1
T
Prok dv ’s offers a range of products for
protection of water pumps used by farmers.
These are primarily to monitor incoming 3-
phase supply for Single Phasing, Reverse
Phasing and unbalanced supply and stop the
pump in case of any fault. Additional features
in some models include auto restarting.The
p r o d u c t s a r e s p e c i f i c a l l y p r o d u c e d
formarketing and use in India only.
Ordering Instructions
Product Family Name
Model Name
System Supply Voltage
Aux. Supply / Control
supply voltage
Motor rating (HP / KW)
Motor applications
Monitor incoming 3-phase supply
Models with pre-wired connections
Easy to fit inside most motor starters
Switch forAuto-Manual operations
Switch provision either built-in or external
Adjustable on time delay
All protections in auto & manualmodes
Built-in timer for star-delta operation
Single Phasing
Reverse Phasing
Unbalanced supply
Dry running
On Delay to avoid immediate restarting of pumps during auto mode
√
FEATURES
PROTECTIONS/FUNCTIONS
MODELS
√
√
√
√
√
13
PRODUCTS FOR
AGRI SECTOR
PDVSP2 B1
PDVSP3 B1
Smallest size of single
Phasing preventor
Single phasing, Reverse
Phasing, Unbalanced supply
Auto reset, 1 NO output
contact Suitable for any
HP/kW rating monoblock
pumps
415 VAC ± 20%, 50 Hz ± 3%
1 NO
5 Amp, 240 VAC (RESISTIVE)
45V± 15V
3.5 sec. ± 1.5 sec.
N.A.
N.A.
N.A.
Auto Reset
N.A.
HIP moulded, with Nylon connector strip
102.5x65.5x43
91 x48
Panel Mounting
260gms
Supply Voltage
Output Relay Contact
Output Contact Rating
Unbalance Trip Setting
Trip Time Delay
For unbalance
Dry Run Setting
On Time Delay
Star-Delta Changeover
Time Delay
Resetting
Auto Switch
Enclosure
Dimensions (mm)
Overall (H xWxD)
Mounting
Mounting
Weight
Level sensor
Quantity
Dimensions
Operating Conditions
-5 TO+ 60
Upto 95% Rh
14
Product
Temperature
Humidity
X X X X X X
Remove this link
RED
GRAY
YELLOW
BLUE
R Y B
GRAY
R Y BR Y B
R Y B
XXX XX XX XX XX
XX
XX
XX
XX
XX
XX
XXXX
PRODUCTS FOR AGRISECTOR
Model
415 VAC ± 20%, 50 Hz ± 3%
1 NO
5 Amp, 240 VAC (RESISTIVE)
45V± 15V
3.5 sec. ± 1.5 sec.
N.A.
N.A.
N.A.
Auto Reset
N.A.
HIP moulded
102.5x65.5x43
91 x48
Panel Mounting
255gms
-5 TO+ 60
Upto 95% Rh
Single Phasing, Reverse
Phasing, Unbalanced supply,
Auto reset, 1 NO Output
Contact ,Suitable for any
HP/kW rating monoblock
pumps.Pre-wired terminals
for easy connections
PDVSP2 B1 PDVSP3 B1