Page 2: Prod Cat 06 - heatweb.com

The brand of choicethe boiler for you�

THE BRANDOF CHOICE

Quality & ReliabilityWith more than one million boilers installed around the UK and withthe backing of the global Riello Group, Vokèra is recognised for thequality and reliability of its products. At every stage, from researchand development through to production and after sales support,we build quality in. Safety is our number one priority, Vokèra is ISO9001 approved, supports the ‘benchmark’ initiative, are membersof the Heating and Hot Water information Council, the Society ofBritish Gas Industries and CORGI. In support of this we back ourproducts with a 2 year warranty.

ChoiceVokèra specialises in the domestic market and provides productsthat fulfil modern domestic requirements. Our product rangeincorporates a product for every domestic application, from systemboilers to high efficiency condensing boilers to water heaters.

VersatilityVokèra products are available in natural gas and LPG versions. Kits are also available to allow simple conversion to a different gas type. A wide range of flue options means that Vokèraappliances are extremely versatile – there isn’t any place in thehome where they can’t be installed.

EfficiencyThe latest technology is used to maximise the efficiency of allVokèra products. All Vokèra boilers conform to the SEDBUKrequirements of the Building Regulations. SEDBUK is agovernment standard which measures seasonal efficiency of all boilers.

Italian StyleItaly is renowned around the world for being at the forefront of styleand taste. Vokèra products bring classic Italian flair and elegance tohome heating.

The Riello Research &Development Centre

The revolutionary new aluminium heat exchanger

Page 3: Prod Cat 06 - heatweb.com

Product rangeIntroducing the Vokèra range ........................................................................................................................................................................04Linea HEHigh efficiency combi boiler ..........................................................................................................................................................................06Unica HEHigh efficiency combi boiler ..........................................................................................................................................................................08Compact HEHigh efficiency combi boiler ..........................................................................................................................................................................10Mynute HEHigh efficiency system boiler ........................................................................................................................................................................12Linea Max HE & Linea MaxHigh efficiency and Standard efficiency floor standing combi boilers ............................................................................................................14Linea 7 seriesStandard efficiency combi boiler ...................................................................................................................................................................16CompactStandard efficiency combi boiler ...................................................................................................................................................................18MynuteStandard efficiency system boiler ................................................................................................................................................................. 20CondexaPROLight commercial wall hung condensing boiler ............................................................................................................................................. 22AquaNovaInstantaneous multipoint water heater .......................................................................................................................................................... 24Flue GuideFlue guidance and options .......................................................................................................................................................................... 25Product features reference chartQuick product feature reference chart to High efficiency and Standard efficiency boilers ............................................................................. 30Service & TrainingActiv service and Activ training ..................................................................................................................................................................... 31

High

Effi

cien

cyHE

Stan

dard

Effi

cien

cyInd

ex03

NEW

NEW

Page 4: Prod Cat 06 - heatweb.com

Mynute HEhigh efficiency system boiler�

Unica HEhigh efficiency combi boiler�Linea HE

high efficiency combi boiler�

Compact HEhigh efficiency combi boiler�

Introducing the Vokèra RangeA sleek, efficient Vokèra boiler will provide a trouble-free focal point for any central heatingsystem. Our extensive range offers the right choice for every home and application, choosingthe right boiler shouldn’t have to mean limited choice. Our range comes in a variety of outputssuitable for any domestic application. Versatile flueing options and natural gas/LPG flexibilitymeans that virtually any home can enjoy the benefits of a Vokèra boiler.

High Efficiency Condensing TechnologyA Vokèra high efficiency model is amongst the most energy efficient boilers available today. These condensingboilers dramatically reduce wasted heat, saving money and helping to protect the environment too.

Combi boilersCentral heating and instant hot water at the turn of a tap - no waiting for the cylinder to warm up and no need forspace consuming tanks.

System boilersIn contrast to other options, these boilers have major system components such as the pump and expansion vesselbuilt-into the boiler itself. They’re quick to install, easy to service and highly cost-effective.

INTRODUCINGTHE VOKERA RANGE

NEW

NEW

Page 5: Prod Cat 06 - heatweb.com

The Vo

kèra range

05

Linea 7 seriesstandard efficiencycombi boiler

Linea max HE& Linea maxfloor standing high efficiencyand standard efficiencycombi boilers

� CondexaPROlight commercial wall hungcondensing boiler

Aquanovawater heater�

Compactstandard efficiencycombi boiler

Mynutestandard efficiencysystem boiler

Standard EfficiencyVokèra’s Standard Efficiency range features both wall-mounted and floor standing options with models to suitevery size of home.

Page 6: Prod Cat 06 - heatweb.com

Linea HEhigh efficiency combi boiler�

LINEA HE HIGH EFFICIENCYCOMBI BOILER

Features and benefitsSEDBUK ‘A’ rated.

Reduces running costs by up to 35% more than a conventionalboiler, helping to safeguard the environment.

Designed for easy installation. A pre-fixing jig and built-in filling loopallows the system to be connected and tested without the boilerneeding to be in place. Standard Vokèra pipework layout enablestrouble-free replacement of older Vokèra models.

Factory set for simple commissioning. Only minimal adjustments are required after installation and automatic modulation eliminates the need to range rate the boiler.

New aluminium heat exchanger.

Low pressure loss reduces noise and increases pump performance.

OT+ communication protocol – industry standard method of controls/communications for remote controls etc.

Low-NOx – Class-5 performance.

Anti-cycling control prevents energy wasteful on/off cycling andreduces wear and tear.

Minimal appliance heat loss removes the need for compartment ventilation to assist cooling.

Built-in frost thermostat protects the appliance from damage during periods of cold weather.

Self-start programming protects the pump and motorised valve fromsticking during long periods of inactivity.

Easy to understand diagnostic display speeds installation andcommissioning and aids the service engineer in the unlikely event of a fault developing.

Seasonality function with 4-different modes of operation ensuresappliance delivers optimum performance and efficiency throughoutthe year.

“Autostop” patented function: Linea HE has a built-in disablingfunction (Autostop) that automatically changes the current operatingmode, and moves it permanently into the standby mode. Thisautomatic function will only operate after a pre-defined period of timehas elapsed.

Versatile flueing options that can reach lengths up to 65 metres, enabling the boiler to be sited almost anywhere in the home.

Clean styled, Italian designed casing blends easily into any setting.

Linea HE control panel

General enquiries: 0870 333 0220 Vokèra Ireland: 056 7755057 [email protected] www.vokera.co.uk�

High Efficiency Boilers

New patented “Autostop“built-in function

Page 7: Prod Cat 06 - heatweb.com

Linea HE

high efficiency combi boiler

07

Linea HE specificationLinea25HE

Linea30HE

Linea35HE

Linea25HE

Linea30HE

Linea35HE

Flue Details (concentric)Maximum horizontal flue length (60/100mm) 7.8 mMaximum vertical flue length (60/100mm) 8.8 mMaximum horizontal flue length (80/125mm) 20.0 mMaximum vertical flue length (80/125mm) 21.0 mFlue Details (twin pipes)Maximum horizontal flue length (80mm+80mm) 40m + 40m 65m + 65m 65m + 65mMaximum vertical flue length (80mm+80mm) 40m + 40m 65m + 65m 65m + 65mEfficiencySEDBUK (%) 90.12 (A) 90.30 (A) 90.03 (A)

Central HeatingHeat input (kW) 25 30 34.6Maximum heat output @ 60/80 °C (kW) 24.4 29.4 33.7Maximum heat output @ 30/50 °C (kW) 26.1 31.56 36.7Domestic Hot WaterHeat input (kW) 25 30 34.6Flow rate - 35 °C rise (l/min.) 10.2 12.3 14.2ConnectionsFlow & return 22 mmGas 15 mmDHW hot & cold 15 mmSafety valve 15 mmCondense 21 mmElectricalVoltage (V/Hz) 230/50hz

Flue gas analysis test point

Aluminium radial heat exchanger

Premix burner

Condensate level sensor

Electric insulation IPX5D

Easy maintenance condensate siphon

Anti-seize function on pump

Anti-seize function on 3-way valve

Automatic by-pass on heating circuit

DHW Plate heat exchanger

Electronic pressure transducer

Analogue pressure gauge

Innovative hydraulic manifold in composite material for quick and easy maintenance

Frost protection via PCB

Dimensions and clearancesLinea HE (dimensions in mm)

Page 8: Prod Cat 06 - heatweb.com

Intuitive control panel ensures end-users can easily operate andadjust the appliance.

"Autostop" patented function: Unica HE has the built-in disabling function (Autostop) that automatically changes thecurrent operating mode, and moves it permanently into thestandby mode. This automatic function will only operate after apre-defined period of time has elapsed and if it has beenactivated during commissioning.

Versatile flueing options enable the boiler to be sited almostanywhere in the home.

Pump anti-block eliminates the risk of pump seizure duringperiods of inactivity.

Built-in thermoregulation to increase further fuel efficiency.

OT+ communication protocol - industry standard method ofcontrols/communications for remote controls etc.

Cleanly styled, Italian designed casing blends easily into any setting.

Unica HEhigh efficiency combi boiler�

UNICA HE HIGH EFFICIENCYCOMBI BOILER

Features and benefitsSEDBUK ‘A’ rated.

Low-NOx - Class-5 performance.

Reduces running costs by up to 35% more than a conventionalboiler, helping to safeguard the environment.

Patented aluminium heat exchanger providing excellent thermaltransfer and anti-corrosion properties.

Designed for easy installation. A pre-fixing jig and built-in fillingloop allows the system to be connected and tested without theboiler needing to be in place. Automatic bypass and easy-fitcondense connection as well as standard Vokèra pipeworklayout enables trouble-free replacement of older Vokèra models.

Factory set and tested for easy commissioning, no need to checkburner pressure or carry out a combustion analysis check.Automatic modulation eliminates the need to range rate the boiler.

Extremely high modulation ratio, increasing efficiency andcomponent longevity.

Hot water pre-heat provides instant hot water at any time, savingtime and energy.

Self-start programming protects the pump and motorised valvefrom sticking during long periods of inactivity.

Anti-cycling control prevents energy wasteful on/off cycling andreduces wear and tear.

Integral clock/programmer, enabling direct control over thecentral heating timings.

Built-in frost thermostat protects the appliance from damageduring periods of cold weather. Unica HE control panel

Sales, General Enquiries: 0870 333 0220 Vokèra Ireland: 056 7755057 [email protected] www.vokera.co.uk�

High Efficiency Boilers

New patented “Autostop“built-in function

NEW

Page 9: Prod Cat 06 - heatweb.com

Unica H

Ehigh efficiency com

bi boiler09

Aluminium radialheat exchanger

Easy maintenancecondensate syphon

Electric insulationIPX5D

Anti-seizefunction on pump

Pressure switch

Anti-seize functionon 3-way valve

Premixburner

DHW stainless steelplate heat exchanger

Innovative hydrolicmanifold in compositematerial for quick andeasy maintenance

Frost protectionvia PCB

Condensatelevel sensor

Flue gas analysistest point

Automatic by-passon heating circuit

Unica HE specificationUnica28HE

Unica32HE

Unica36HE

Unica28HE

Unica32HE

Unica36HE

Flue Details (concentric)Maximum horizontalflue length (60/100mm) 7.8m 7.8m 7.8mMaximum verticalflue length (60/100mm) 8.8m 8.8m 8.8mMaximum horizontalflue length (80/125mm) 20m 20m 20mMaximum verticalflue length (80/125mm) 25m 25m 25mFlue Details (twin pipes)Maximum horizontalflue length (80mm/80mm) 40m/40m 35m/35m 35m/35mMaximum verticalflue length (80mm/80mm) 40m/40m 35m/35m 35m/35mEfficiencySEDBUK (%) 90.5 90.2 90.1

Central HeatingHeat input (kW) 20 25 30Maximum heat output@ 60/80 °C (kW) 19.7 24.45 29.31Maximum heat output@ 30/50 °C (kW) 21.0 26.3 31.83Domestic Hot WaterHeat input (kW) 28 32 36Flow Rate: T35°C (l/pm) 11.5 13.1 14.7WeightDry weight (kg) 40 42 45ConnectionsFlow & return 22mm 22mm 22mmGas 15mm 15mm 15mmDHW hot & cold 15mm 15mm 15mmSafety valve 15mm 15mm 15mmCondense 21mm 21mm 21mmElectricalVoltage (V/Hz) 230/50 230/50 230/50

Unica 28HE Unica 32/36HE

Dimensions and clearancesUnica HE (dimensions in mm)

Page 10: Prod Cat 06 - heatweb.com

Compact HEhigh efficiency combi boiler�

COMPACT HE HIGH EFFICIENCYCOMBI BOILER

Features and benefitsSEDBUK ‘B’ rated.

Gas pressure set by gas valve, therefore no flue GasAnalyser required.

Reduces running costs by up to 35% more than a conventionalboiler, helping to safeguard the environment.

Designed for easy installation. Standard Vokèra pipework layoutenables trouble-free replacement of older Vokèra models.

Factory set for simple commissioning. Only minimal adjustmentsare required after installation and automatic modulationeliminates the need to range rate the boiler.

Anti-cycling control prevents energy wasteful on/off cyclingand reduces wear and tear.

Built-in frost thermostat protects the appliance from damageduring periods of cold weather.

LPG version available.

Versatile flueing options enable the boiler to be sited almostanywhere in the home.

Cleanly styled, Italian designed casing blends easily into any setting.

Plated heat exchanger reduces the risk of scaling and comeswith 5-year anti-scale warranty.

Equipped with the Vokèra patented Seasonal AdvancedRegulation Action (S.A.R.A). This feature automatically managesthe Central Heating output temperature depending on therequired level of comfort.

The IPX5D Ingress protection increases safety for the end-user.

Installation time saving features:- Built-in condense trap withsafety device and push-fit connection, Factory fitted fly-lead andno ventilation is required.

Built-in mechanical clock.

Combustion analysis test point for easy servicing andmaintenance.

Sales, General Enquiries: 0870 333 0220 Vokèra Ireland: 056 7755057 [email protected] www.vokera.co.uk�

High Efficiency Boilers

Compact HE control panel

Page 11: Prod Cat 06 - heatweb.com

Flue outlet

Full gas modulation accurately matches heatoutput to demand

Latent heat collector maximises amount of usefulheat taken from flue gas

Pump

Advanced electronic control

Co

mp

act HE

high efficiency combi boiler

11

Dimensions and clearancesCompact HE (dimensions in mm)

Compact HE specification

Compact25HE

Compact29HE

Compact 29HECompact 25HE

Compact35HE

Compact25HE

Compact29HE

Compact35HE

Rated output to DHW 24.3 kW 28.1 kW 33.8 kWCentral heating output (80°C/60°C) 24.3 kW 28.1 kW 33.8 kW

(50°C/30°C) 25.9 kW 29.7 kW 36.0 kWHot water flow rate (35°C rise) 10.2 l/min 11.9 l/min 13.9 l/minStandard flue terminal length 1000 mm 1000 mm 1000 mmSeasonal Efficiency (SEDBUK) rating Band B Band B Band BMin. cold water inlet pressure 0.15 bar 0.15 bar 0.15 barExpansion vessel 8 litres 8 litres 8 litresSystem volume 76 litres 76 litres 76 litresWeight (Dry) 40 kg 44 kg 48 kgMaximum flue lengthHorizontal (60/100) concentric 4.5 m 4.0 m 1.2 mVertical (60/100) concentric 5.5 m 5.0 m 2.2 mHorizontal (80/125) concentric 11 m 9 m 6.75 mVertical (80/125) concentric 12 m 10 m 8.5 mMaximum twin flue length(Horizontal or vertical) + terminal 20/20 m 12/12 m 10/10 m

Electrical dataElectrical 230 Vac 230 Vac 230 VacPower consumption 153 W 153 W 195 WPipe connectionsFlow 22 mm 22 mm 22 mmReturn 22 mm 22 mm 22 mmDHW 15 mm 15 mm 15 mmCold water 15 mm 15 mm 15 mmGas 15 mm 15 mm 15 mmCondensate 21 mm 21 mm 21 mmSafety Valve 15 mm 15 mm 15 mmBoiler dimensionsHeight 780 mm 780 mm 780 mmWidth 400 mm 450 mm 500 mmDepth 332 mm 332 mm 332 mm

Compact 35HE

Page 12: Prod Cat 06 - heatweb.com

Mynute HEhigh efficiency system boiler�

MYNUTE HE HIGH EFFICIENCYSYSTEM BOILER

Features and benefitsSEDBUK ‘A’ rated.

Reduces running costs by up to 35% more than a conventionalboiler, helping to safeguard the environment.

New aluminium heat exchanger. This heat exchanger providesexcellent thermal transfer and anti corrosion properties and isfully recyclable.

Low pressure loss reduces noise and increases pumpperformance.

Designed for easy installation.

Factory set and tested for easy commissioning, no need to checkburner pressure or carry out a combustion analysis check.Automatic modulation eliminates the need to range rate the boiler.

Extremely high modulation ratio, increasing efficiency andcomponent longevity.

Low-NOx - Class-5 performance.

Self-start programming protects the pump from sticking duringlong periods of inactivity.

Anti-cycling control prevents energy wasteful on/off cycling andreduces wear and tear.

Built-in frost thermostat protects the appliance from damageduring periods of cold weather.

Versatile horizontal or vertical flueing options – using Vokèra’sconcentric or twin flue systems – enable the boiler to be sitedalmost anywhere in the home.

OT+ communication protocol - industry standard method ofcontrols/communications for remote controls etc.

"Autostop" patented function: Mynute HE has the built-indisabling function (Autostop) that automatically changes thecurrent operating mode, and moves it permanently into thestandby mode. This automatic function will only operate after apre-defined period of time has elapsed and if it has beenactivated during commissioning.

Integral clock/programmer, enabling direct control over thecentral heating timings.

Pump anti-block eliminates the risk of pump seizure duringperiods of inactivity.

Intuitive control panel ensures end-users can easily operate andadjust the appliance.

Built-in thermoregulation to increase further fuel efficiency.

Cleanly styled, Italian designed casing blends easily into any setting.

Sales, General Enquiries: 0870 333 0220 Vokèra Ireland: 056 7755057 [email protected] www.vokera.co.uk�

High Efficiency Boilers

Mynute HE control panel

New patented “Autostop“built-in function

NEW

Page 13: Prod Cat 06 - heatweb.com

Mynute H

Ehigh efficiency system

boiler13

Central HeatingHeat input (kW) 12 15 20 25 30 34.6Maximum heat output (kW) 60/80°C 11.84 14.81 19.68 24.53 29.31 33.67Maximum heat output (kW) 30/50°C 12.74 15.9 21.16 26.3 31.83 36.54WeightDry weight (kg) 36 36 36 37 42 42ClearancesSides 12mm 12mm 12mm 12mm 12mm 12mmTop* 150mm* 150mm* 150mm* 150mm* 150mm* 150mm*Bottom 150mm 150mm 150mm 150mm 150mm 150mmFront 600mm 600mm 600mm 600mm 600mm 600mmConnectionsFlow & return 22mm 22mm 22mm 22mm 22mm 22mmGas 15mm 15mm 15mm 15mm 15mm 15mmSafety valve 15mm 15mm 15mm 15mm 15mm 15mmCondense 21mm 21mm 21mm 21mm 21mm 21mmFlue Details (concentric & twin)Maximum horizontal flue length (60/100mm) 7.8m 7.8m 7.8m 7.8m 7.8m 7.8mMaximum vertical flue length (60/100mm) 8.8m 8.8m 8.8m 8.8m 8.8m 8.8mMaximum horizontal flue length (80/125mm) 20.0m 20.0m 20.0m 20.0m 20.0m 20.0mMaximum vertical flue length (80/125mm) 25.0m 25.0m 25.0m 25.0m 25.0m 25.0mMaximum horizontal flue length (80mm/80mm) 40m/40m 40m/40m 40m/40m 40m/40m 40m/40m 40m/40mMaximum vertical flue length (80mm/80mm) 40m/40m 40m/40m 40m/40m 40m/40m 40m/40m 40m/40mFlue type approvals C13 – C23 – C33 – C43 – C53 – C83 – B23EfficiencySEDBUK Band ‘A’ (%) 90.7 90.7 90.5 90.4 90.2 90.0

Aluminium radialheat exchanger

Easy maintenancecondensate syphon

Electric insulationIPX5D

Anti-seizefunction on pump

Premixburner

Pressureswitch

Hydraulic brass manifoldinclusive of automaticby-pass, drain valve andsafety valve

Frost protectionvia PCB

Flue gas analysistest point

Mynute HE specificationMynute12HE

Mynute15HE

Mynute20HE

Mynute25HE

Mynute30HE

Mynute35HE

*from casing or 25mm above flue elbow (whichever is applicable)

Mynute 12/15/20HE Mynute 25HE Mynute 30/35HE

Dimensions and clearancesMynute HE (dimensions in mm)

Condensatelevel sensor

Page 14: Prod Cat 06 - heatweb.com

Linea Max HE& Linea Maxfloor standing high output high efficiency & standardefficiency combi boilers

LINEA MAX HIGH & STANDARD EFFICIENCYFLOOR STANDING COMBI BOILERS

Features and benefits

SEDBUK ‘B’ rated for high efficiency and ‘D’ rated forstandard efficiency.

High domestic hot water flow rate makes Linea Max HE andLinea Max ideal for larger homes.

55% more flow rate than a combi of an equivalent output.

An integrated 60 litre thermal store boosts domestic hot waterdelivery to 18 litre/min.

The unique ‘wheel-in’ fixing jig allows pipes to be connected to abase tray without the boiler in place. Then simply slide boiler inand connect the unions at the front.

Anti-cycling control prevents wasteful on/off cycling of the boiler,eliminating unnecessary wear and tear.

The self-start programme protects the pump and motorised valvefrom sticking during long periods of inactivity.

Linea Max HE and Linea Max can be flued horizontally orvertically using Vokèra’s concentric or twin flue systems makingthe boiler extremely versatile.

Built-in filling loop reduces installation time andmaterial requirements.

Gas pressure set by gas valve, therefore no flue GasAnalyser required.

Unique ‘wheel-in’installation:

Step 1 -

Connect pipeworkto base tray

Step 2 -

Slide in boiler andconnect unions at front

Sales, General Enquiries: 0870 333 0220 Vokèra Ireland: 056 7755057 [email protected] www.vokera.co.uk�

Linea Max HE reduces running costs by up to 35% more than aconventional boiler, helping to safeguard the environment.

Designed for easy installation. Standard Vokèra pipework layoutenables trouble-free replacement of older Vokèra models.

Built-in frost thermostat protects the appliance from damageduring periods of cold weather.

Plated heat exchanger reduces the risk of scaling and comeswith 5-year anti-scale warranty.

High & Standard Efficiency Boilers

Page 15: Prod Cat 06 - heatweb.com

Linea Max H

E &

Linea Max

high efficiency & standard efficiency floor standing com

bi boilers15

Linea Max HE & Linea Max specification

Control panel

Integrated 60 litre thermal store boosts hotwater delivery to 18 litres per min

Pump

Motorised valve

Large domestic stainless steel hot waterheat exchanger

Unique ‘wheel-in’ fixing jig

Fully modulated gas valve

Dimensions and clearancesLinea Max HE & Linea Max (dimensions in mm)

* Until thermal store depleted, then as Linea 28 (or recovery to full performance in approximately 5 minutes)

** The appliance flue elbow on the Linea Max cannot be used with a vertical flue application and should be discarded.

Heat output at 80°C/60°C (kW) 28.1 28.0Heat output 50°C/30°C (kW) 30.2 -DHW flow rate (litres per minute) 18* 18*Standard flue terminal length (mm) 1000 830Maximum flue length horizontal (60/100mm) 2.0m 1.8mvertical (60/100mm) 3.0m 4.4m**horizontal (80+80mm) 12m + 12m 6m + 6mMinimum cold water inlet pressure 0.15 bar 0.15 barExpansion vessel capacity 10-litres 10-litresSystem volume 91-litres 91-litres

Dry weight (kg) 91 88Electrical 230Vac 50Hz 230Vac 50HzPower consumption 150w 130wPipe connectionsFlow 22mm 22mmReturn 22mm 22mmCold water inlet 15mm 15mmHot water outlet 15mm 15mmGas 15mm 15mmCondense 21mm N/ASafety valve 15mm 15mm

Linea Max HE Linea Max Linea Max HE Linea Max

Page 16: Prod Cat 06 - heatweb.com

Linea 7 seriesstandard efficiency combi boiler�

LINEA 7 SERIESSTANDARD EFFICIENCY COMBI BOILER

Features and benefitsLinea 7-Series have a full air/gas modulation system that ensuresoutput is constantly monitored and matched to demand.

Built-in filling loop reduces installation time andmaterial requirements.

A pre-fixing jig simplifies installation and allows all pipework to beconnected and tested without the need for the boiler on site. Thefixing jig is highly advantageous when there is a risk of theft ordamage to the boiler.

Anti-cycling control prevents wasteful on/off cycling of the boiler,eliminating unnecessary wear and tear.

Electronic ignition eliminates the need for a constantly running fanand energy wasteful pilot light.

A pre-heat facility provides a rapid response to demand fordomestic hot water and eliminates water wastage.

Built-in frost protection.

Exceptionally high build quality.

The boiler can be flued horizontally or vertically using Vokèra’sconcentric or twin flue systems.

Optional 7 day or 24 hour timers available to suit the individualneeds of the end user.

Vokèra boilers are factory set and require minimal setting duringcommissioning.

Linea 7-Series are all room sealed boilers allowing siting virtuallyanywhere within the home.

Self-start programme protects the pump and motorised valvefrom sticking during long periods of inactivity.

Sales, General Enquiries: 0870 333 0220 Vokèra Ireland: 056 7755057 [email protected] www.vokera.co.uk�

Standard Efficiency Boilers

Pre-fixing jig with built-in filling loop

Page 17: Prod Cat 06 - heatweb.com

Linea 7 seriesstandard efficiency com

bi boiler17

Pipe space for top connection

Room sealed chamber, negative pressure,fan assisted

Main heat exchanger

Stainless steel burner

Electronic ignition

Pump

Motorised valve

Full air/gas modulation ensures output is constantlymonitored and matched to demand

Advanced electronic control

Dimensions and clearancesLinea 7-series (dimensions in mm)

Linea 726 Linea 730 Linea 735

Rated output to DHW 26.0 kW 30.1 kW 34.9 kWCentral heating output 26.0 kW 30.1 kW 34.9 kWHot water flow rate (35˚C rise) 10.6 l/min 12.3 l/min 14.3 l/minStandard flue terminal length 830mm 830mm 830mmMaximum flue lengthHorizontal (ø100mm) 4.0m 3.4m 2.0mVertical (ø100mm) 4.8m 4.2m 2.8mTwin (ø80/80mm) 14m/14m* 14m/14m* 7m/7m*Min. cold water inlet pressure 0.15 bar 0.15 bar 0.15 barExpansion vessel (1 bar) 8 litres 8 litres 10 litresSystem volume 76 litres 76 litres 91 litres

Weight (Dry) 41Kg 43Kg 48KgElectrical 230Vac 50HzPower consumption 125 W 125 W 125 WPipe connectionsFlow 22mm 22mm 22mmReturn 22mm 22mm 22mmDHW 15mm 15mm 15mmCold water 15mm 15mm 15mmGas 15mm 15mm 15mmSafety Valve 15mm 15mm 15mmExternal Switching 230Vac

Linea 7 series specification

Linea726

Linea730

Linea735

Linea726

Linea730

Linea735

* plus flue terminal

Page 18: Prod Cat 06 - heatweb.com

Compactstandard efficiency combi boiler�

COMPACT STANDARD EFFICIENCYCOMBI BOILER

Features and benefitsChoice of 24kW or 28kW outputs.

Top flue outlet with an optional rear flue exit within thecase height.

Patented ‘bi-thermic’ heat exchanger provides rapid delivery ofhot water.

Simple, reliable operation. Integrated components minimiseservice requirements saving time and money.

Built-in 24 hour time clock.

Built-in frost protection.

Anti-cycling control prevents wasteful on/off cycling of the boiler,eliminating unnecessary wear and tear of the boiler.

Built-in automatic by-pass.

Easy to use temperature selectors provide simple and accuratecontrol of the boiler.

Electronic ignition eliminates the need for a constantly runningfan or energy wasteful pilot light.

Advanced flame modulation matches output to demand tomaximise the efficient use of fuel.

Exceptionally high build quality using commonly availableproven components.

Choice of horizontal or vertical flue using Vokèra’s concentric ortwin flue systems.

Self-start programme protects pump from sticking during longperiods of inactivity.

Auto-temperature regulation feature optimises boiler outputto demand.

Sales, General Enquiries: 0870 333 0220 Vokèra Ireland: 056 7755057 [email protected] www.vokera.co.uk�

Standard Efficiency Boilers

Hanging bracket and rear flue outlet template

Page 19: Prod Cat 06 - heatweb.com

Co

mp

actstandard efficiency com

bi boiler19

Compact specification

Dimensions and clearances Compact (dimensions in mm)

Room sealed chamber, negative pressure, fan assisted

Bi-thermic heat exchanger

Stainless steel burner

Pump

Electronic ignition

Fully modulating gas valve

Advanced electronic control

Compact 24 Compact 28

Rated output to DHW 24.0 kW 28.0 kWCentral heating output 24.0 kW 28.0 kWHot water flow rate (35˚C rise) 9.8 l/min 11.5 l/minStandard flue terminal length 630mm* 630mm*Maximum flue lengthHorizontal (ø100mm) 4.25mm 3.4mmVertical (ø100mm) 5m 4.2mTwin (ø80/80mm) 14m/14m + terminalMinimum cold water inlet pressure 0.15 bar 0.15 barExpansion vessel (1 bar) 8 litres 8 litres

Compact 24 Compact 28Compact 24 Compact 28 Compact 24 Compact 28

* Maximum length of standard rear outlet telescopic flue suitable for wall thickness 210mm - 435mm

System volume 76 litres 76 litresWeight (Dry) 34kg 37kgElectrical 230Vac 230Vac

50Hz 50HzPower consumption 125 W 125 WPipe connectionsFlow 22mm 22mmReturn 22mm 22mmDHW 15mm 15mmCold water 15mm 15mmGas 15mm 15mmSafety Valve 15mm 15mmExternal Switching 230Vac

Page 20: Prod Cat 06 - heatweb.com

Mynutestandard efficiency system boiler�

MYNUTE STANDARD EFFICIENCYSYSTEM BOILER

Features and benefitsAll system components, including the pump, expansion vessel,safety valve and automatic air vent are built-in, saving spacealong with installation time and materials.

Dry loft possible. No expansion tank is required in the loft spacewhich minimises the possibility of frozen pipes and tanks.

Compact, stylish casing.

Simplified servicing and maintenance. All working componentsare all in one place.

Choice of models from 12kW to 35kW providing an output forevery home.

The boiler can be flued horizontally or vertically using Vokèra’sconcentric or twin flue systems.

Mynute can operate on natural gas, LPG or Town Gas (excluding35e), making it extremely versatile.

Optional built-in programmers are available to allow automatictimed control of both heating and hot water.

Built-in frost protection. (Mynute 28e & 35e)

Anti-cycling control prevents wasteful on/off cycling of the boiler,eliminating unnecessary wear and tear.

Self-start feature which protects the pump from sticking duringlong periods of inactivity.

Electronic ignition eliminates the need for a constantly runningfan or energy wasteful pilot light.

Mynute can easily be connected to a standard or unvented hotwater cylinder.

Fully modulating burner (Mynute 28e & 35e) which accuratelymatches output to demand.

Can be linked to other Vokèra boilers for larger output modularapplications.

Mynute 12e, 16e, 20e

Mynute 28e, 35e

Sales, General Enquiries: 0870 333 0220 Vokèra Ireland: 056 7755057 [email protected] www.vokera.co.uk�

Standard Efficiency Boilers

Page 21: Prod Cat 06 - heatweb.com

Mynute

standard efficiency system boiler

21

Mynute 12e, 16e, 20e Mynute 28e, 35e

Mynute 12e, 16e, 20e Mynute 28e

Dimensions and clearances Mynute 12e, 16e, 20e (dimensions in mm) Dimensions and clearances Mynute 28e, 35e (dimensions in mm)

Compare the materials andinstallation time you save with a system boiler:

Conventional Boiler System boiler

Boiler BoilerFlue kit Flue kitFeed and expansion tank Filling loop– fittings and insulation

Copper pipe and fittings (cold mains/feed/vent)Pump and gate valvesExtra labour

Mynute specification

Central heating output 12 kW 16 kW 20 kW 28 kW 34.9 kWStandard flue terminal length 830mm 830mm 830mm 830mm 830mmMaximum flue lengthHorizontal (ø100mm) 4.5m 3.4m 3.4m 3.4m 2.0mVertical (ø100mm) 5.5m 4.4m 4.4m 4.4m 2.8mTwin (ø80/80mm) 14m/14m* 14m/14m* 14m/14m* 14m/14m* 7m/7m*Expansion vessel (1 bar) 6 litres 6 litres 6 litres 10 litres 10 litresSystem volume 55 litres 55 litres 55 litres 91 litres 91 litresWeight (Dry) 30kg 30kg 30kg 40kg 45kgElectrical 230Vac 50Hz 230Vac 50Hz 230Vac 50Hz 230Vac 50Hz 230Vac 50HzPower consumption 125 W 125 W 125 W 130 W 125 WPipe connectionsFlow 22mm 22mm 22mm 22mm 22mmReturn 22mm 22mm 22mm 22mm 22mmGas 15mm 15mm 15mm 15mm 15mmSafety Valve 15mm 15mm 15mm 15mm 15mmExternal Switching 230Vac 230Vac 230Vac 230Vac 230Vac

Mynute 35e

* plus flue terminal

Mynute 35eMynute 28eMynute 20eMynute 16eMynute 12e

Page 22: Prod Cat 06 - heatweb.com

CondexaPROlight commercial wall hung condensing boiler

features and benefits

SEDBUK Band ‘A’ rated

Modular system and a pre-mixed and air blown burner consistingof one or more heating elements installed in series. The usefuloutput produced by each heating unit reaches 48.0 kW (100%,50°C-30°C) and modulates between 30% and 100%.

Stainless steel condensing exchanger on the exhaust side andcopper alloy exchanger on the water side, each generatorreaches 108.7% as the calorific value produced by natural gas(Hi) is lower; the low temperatures produced by the exhaustgases discharged into the atmosphere allow the use of a built-in50mm diameter plastic exhaust collector with female fitting whichmay reach an equivalent height of 30m.

These heating units ensure low running costs, reliability andflexibility.

They boast latest generation electronic control, modularity andversatility, thus ensuring the installer a quick connection to anytype of heating and hot water storage systems as itsimultaneously controls three different circuits, each operating atdifferent temperatures.

The CondexaPRO units are designed to provide water to 3different circuits at different temperatures either supplied as directtake off’s or via a header system utilising controls as required.With this in mind suggested usage are DHW, High Temperature(heating) & Low Temperature (under floor heating).

Flue outlet up to 30m long.

Water drain built-in as standard in the boiler for each heating unit.

Temperature control built-in as standard.

Automatic burner ignition sequence reversal.

Anti-legionnaires’ disease function (only available with roomcontrol kit).

Weekly programmer (only available with room control kit).

With the above in mind the flexibility of the boilers makes it idealfor both new build and refurbishment.

options

Choice of flueing options.

Manifold (up to 100 kw).

Manifold (over 100 kw).

Room control kit.

2-way isolating valve.

Injection pump.

Room sealed kit CondexaPRO 50.

Room sealed kit CondexaPRO 100.Sales, General Enquiries: 0870 333 0220 Vokèra Ireland: 056 7755057 [email protected] www.vokera.co.uk�

CondexaPRO control panel

CONDEXAPRO LIGHT COMMERCIAL WALL HUNGCONDENSING BOILER

High Efficiency Boilers

Page 23: Prod Cat 06 - heatweb.com

50 kW1 CondexaPRO 50M

100 kW1 CondexaPRO 100M

150 kW1 CondexaPRO 50M

1 CondexaPRO 100S

200 kW1 CondexaPRO 100M1 CondexaPRO 100S

250 kW1 CondexaPRO 50M

2 CondexaPRO 100S

300 kW1 CondexaPRO 100M2 CondexaPRO 100S

350 kW1 CondexaPRO 50M

3 CondexaPRO 100S

400 kW1 CondexaPRO 100M3 CondexaPRO 100S

typical installations

Room control kit

Heat output at 80/60˚C 44.2 kW 88.3 kW 88.3 kWHeat output at 50/30˚C 48.5 kW 96.8 kW 96.8 kWFlow rate at 20˚C 33.0 l/min 66.7 l/min 66.7 l/minWaterside pressure drop at 20˚C 700 mbar 700 mbar 700mbarMaximum water pressure 6.0 bar 6.0 bar 6.0 barMinimum water pressure 0.5 bar 0.5 bar 0.5 barMaximum water temperature (flow) 80˚C 80˚C 80˚CFlue connection 1 x 50mm 2 x 50mm 2 x 50mmPower supply 230v 1PH 230v 1PH 230v 1PH

50Hz 50Hz 50HzStart current 0.8A 1.6A 1.6ARun current 0.74A 1.45A 1.45AWidth 600mm 600mm 600mmDepth 380mm 380mm 380mmHeight 1000mm 1000mm 1000mmDry weight 60kg 90kg 90kg

CondexaPRO specification

CondexaPRO50M

CondexaPRO100M

CondexaPRO100S

Co

ndexaP

RO

light comm

ercial wall hung condensing boiler

23

Page 24: Prod Cat 06 - heatweb.com

AquaNovainstantaneous multipointwater heater

AQUANOVAWATER HEATER

Features and benefitsSimple installation and commissioning. All connections are easilyaccessible and the appliance features a built-in flying lead.

AquaNova has a 28kW heat output and high flow rate of 11.8litres per minute.

Continuous gas modulation and electronic temperature sensinggives accurate temperature control.

AquaNova can be flued horizontally or vertically using Vokèra’sconcentric or twin flue systems.

Simple to service. No diaphragm or water section. This reducesmaintenance requirements.

Electronic ignition eliminates the need for a constantly running fanor energy wasteful pilot light.

AquaNova specificationRated output to DHW 28.8 kW Weight (Dry) 20kgHot water flow rate (35˚C rise) 11.8 litres/min Electrical 230Vac 50HzStandard flue terminal length 830mm Power consumption 85 WMaximum flue length Pipe connectionsHorizontal (ø100mm) 2.4m DHW 15mmVertical (ø100mm) 3.6m Cold water 15mmTwin (ø80mm) 5m/5m + terminal Gas 15mmMinimum cold water inlet pressure 0.15bar

Sales, General Enquiries: 0870 333 0220 Vokèra Ireland: 056 7755057 [email protected] www.vokera.co.uk�

Dimensions and clearances AquaNova (dimensions in mm)

Page 25: Prod Cat 06 - heatweb.com

Flues

subhead25

Fluesintroduction

Vokèra offer a wide range of flue systems that are able to meet themajority of applications. There are concentric flue systems and aparallel (twin) flue system that can be used in either horizontal orvertical configurations.

60/100mm CONCENTRIC Our 60/100 Uni-flue range (for SE appliances) and 60/100condensing range (for HE appliances) are the most widely usedand will suit most applications that are usually encountered.

80/125mm CONCENTRICThe 80/125 range is suitable for use on specific appliances andsuits applications where a slightly longer concentric flue systemis required.

80mm + 80mm PARALLEL (twin)The 80mm + 80mm parallel (twin) range can be utilised where anextremely long flue run is envisaged, or required.

All Vokèra flue systems incorporate simple to use, push-fitconnections that are designed to enable a fast and simple methodof installation. The attractive white finish complements the moderndesign of our appliances.

Terminal positions

Flue systems and terminal locations should be located andinstalled in accordance with current Building Regulations (UK) orI.S. 813 (ROI). The terminal should be located where the dispersalof combustion products is not impeded and with due regard forthe damage and/or discolouration that may occur to buildingproducts located nearby.

The terminal must not be located in a place where it is likely tocause a nuisance. Water vapour may condense on leaving theterminal. The effect of such plumbing must be considered.

Flue Exits Minimum distance SE & HE Boilers

A Below an opening (window, airbrick etc) 300mm

B Below gutters, drain pipe etc 25mm

C Below eaves 25mm

D Below balcony, carport roof etc 25mm

E To side of a vertical soil/drain pipe etc 25mm

F From internal or external corner or boundary 25mm

G Above ground, roof or balcony level 300mm

H From a surface or boundary facing a terminal 600mm

I From a terminal facing a terminal 1200mm

J From an opening in the carport into the building 1200mm

K Vertically from a terminal on the same wall 1500mm

L Horizontally from a terminal on the same wall 300mm

M From a structure to the side of a vertical terminal 500mm

N To the side of an opening (window, airbrick etc) 300mm

P Above an opening (window, airbrick etc) 300mm

Q From the top of a vertical terminal to the roof flashing As determined by fixed collar

Please note: measurements for E & F are 60mm when using 80/125mm flue.

flue exit clearances

Page 26: Prod Cat 06 - heatweb.com

Sales, General Enquiries: 0870 333 0220 Vokèra Ireland: 056 7755057 [email protected] www.vokera.co.uk�

FLUE GUIDE

Uni-flue 60/100mm Concentric Flue System for Standard Efficiency Appliances

2359119 Telescopic flue terminal � � � � �

2359029 Horizontal flue terminal (833mm) � � � � �

2359039 Vertical flue terminal (1000mm) � � � � �

2359049 45-deg bend (pair) � � � � �

2359059 90-deg bend � � � � �

2359069 750mm extension � � � � �

2359079 1500mm extension � � � � �

2359089 Telescopic extension (350-490mm) � � � � �

2359139* High-wind terminal � � � � �

2359169 Long jointing clip set � � � � �

450 SE-Duct kit � � � � �

0225760 Wall brackets 100mm X 5 � � � � �

0225765 Flat roof flashing plate (390mm Dia) � � � � �

0225770 Pitched roof flashing plate (500mm X 500mm) � � � � �

0225905 Standard telescopic rear-flue � � � � �

0225910 Extended telescopic rear-flue � � � � �

AquanovaCompactLinea MaxLinea 7MynuteCode Description

60/100mm Concentric Flue Systems�

*Contact Vokèra technical Helpline for specific advice/information

The 60/100 Uni-flue range is suitable for all current Vokèrastandard efficiency (non-condensing) appliances.When used in the horizontal plane, the flue system should beinstalled so that it has a slight incline towards outside (awayfrom the boiler). This will reduce the risk of rainwater enteringthe flue system and/or appliance.

It can also be used as a replacement flue system onolder/obsolete Vokèra room-sealed SE appliances, howeveryou should contact the Vokèra Technical Helpline for specificadvice.

60/100mm Concentric Flue System for High Efficiency Appliances

520 Horizontal flue terminal 917mm (exc. Terminal) � � � � �

530 Vertical flue terminal (1000mm) � � � � �

524 45-deg bend (pair) � � � � �

523 90-deg bend � � � � �

525 500mm extension � � � � �

526 1000mm extension � � � � �

527 2000mm extension � � � � �

528 Telescopic extension (407-587mm) � � � � �

529 Wall brackets 5 x 100mm � � � � �

532 Flat roof flashing plate (340mm dia.) � � � � �

531 Pitched roof flashing plate (480mm-440mm) � � � � �

522 Plume Management Kit � � �* � �

521 Telescopic horizontal flue terminal 407 – 587mm (exc. terminal) � � � � �

Linea MaxHE

MynuteHE

CompactHE

Unica HELinea HECode Description

*Suitable for Compact 25HE only

The 60/100 condensing range is suitable for all currentVokèra high efficiency (condensing) appliances.When used in the horizontal plane, the flue system should beinstalled so that it has a 1o – minimum – fall back to the boiler(17mm per-metre). This will enable any condensate fluid thatmay form, to drain via the condensate connection/trap.

It can also be used as a replacement flue system onolder/obsolete Vokèra HE appliances, however you shouldcontact the Vokèra Technical Helpline for specific advice.

Page 27: Prod Cat 06 - heatweb.com

27

412 Boiler top adaptor for SE appliances � � � � � � �

413 Horizontal terminal � � � � � � �

414 Vertical terminal � � � � � � �

415 90-deg bend � � � � � � �

416 45-deg bend (single) � � � � � � �

417 250mm extension* � � � � � � �

418 500mm extension � � � � � � �

419 1000mm extension � � � � � � �

420 2000mm extension � � � � � � �

421 3000mm extension* � � � � � � �

422 Telescopic extension* � � � � � � �

423 Wall brackets 125mm X 5 � � � � � � �

424 Boiler top adaptor for HE appliances � � � � � � �

425 Fixed offset* � � � � � � �

426 Silicon lubricant � � � � � � �

532 Flat roof flashing plate (390mm Dia) � � � � � � �

531 Pitched roof flashing plate (500mm X 500mm) � � � � � � �

LineaMax HE

Linea 7 Mynute35e

MynuteHE

CompactHE

UnicaHE

LineaHE

Code Description

80/125mm Concentric Flue Systems�

*Available by special order

The 80/125 range can be utilised only with certain specificappliances.When used in the horizontal plane, the flue system should beinstalled so that it has a 1o – minimum – fall back to the boiler(17mm per-metre). This will enable any condensate fluid that

may form, to drain via the condensate connection/trap.An adaptor is required to convert the appliance flue outletfrom 100mm to 125mm.

300 Adaptor kit for Mynute 12e/16e/20e/28e & Compact 24310 Adaptor kit for Aquanova

48958 Adaptor kit for Linea Max430 Adaptor kit for all HE (condensing) boilers362 Adaptor kit for Linea 7-Series & Mynute 35e

2359249 Adaptor kit for Compact 280225805 Horizontal terminal & convertor box0225810 Vertical terminal & convertor box0225815 Condensate drain kit (for SE appliances only)0225820 250mm extension (pair)0225825 500mm extension (pair)0225830 1000mm extension (pair)0225835 2000mm extension (pair)0225840 45-deg bend (pair)0225845 90-deg bend (pair)0225850 Double pipe bracket 80mm X 80mm (5-OFF)0225855 Single pipe bracket 80mm (5-OFF)0225765 Flat roof flashing plate (390mm Dia)0225770 Pitched roof flashing plate (500mm X 500mm)

Code Description

80mm Parallel (twin) Flue Systems�

The 80mm + 80mm parallel system enables greater fluelengths to be achieved and be used in either a horizontal orvertical configuration. However the parallel system must beconverted back to a concentric system at the point oftermination. Dedicated flue kits are available for this purpose.An adaptor kit is required to convert the appliance flue outletfrom a concentric configuration into a parallel configuration.When used in the horizontal plane, the flue system should beinstalled so that it has a 1o – minimum – fall back to the boiler.This will enable any condensate fluid that may form, to drainvia the condensate connection/trap.

A condensate drain kit is available and must be used wherean SE boiler has been installed with a parallelflue system.The exhaust pipe can reach very high temperatures and somust be adequately protected to avoid contact with personsand/or materials that could be damaged as a result.The air inlet pipe should be insulated to reduce the possibilityof condense forming on the outside of the pipe.

Page 28: Prod Cat 06 - heatweb.com

FLUES

Maximum flue lengthsintroduction

Horiz. Vertical Horiz. Vertical Horiz. Vertical Horiz.

Mynute 12e 4.5m 5.5m � � 14m + 14m �

Mynute 16e 3.4m 4.4m � � 14m + 14m �

Mynute 20e 3.4m 4.4m � � 14m + 14m �

Mynute 28e 3.4m 4.4m � � 14m + 14m �

Mynute 35e 2.0m 2.8m 5.0m 5.8m 7m + 7m 7.8m + 7.8m �

Mynute 12HE 7.8m 8.8m 20m 25m 40m + 40m �

Mynute 15HE 7.8m 8.8m 20m 25m 40m + 40m �

Mynute 20HE 7.8m 8.8m 20m 25m 40m + 40m �

Mynute 25HE 7.8m 8.8m 20m 25m 40m + 40m �

Mynute 30HE 7.8m 8.8m 20m 25m 40m + 40m �

Mynute 35HE 7.8m 8.8m 20m 25m 40m + 40m �

Compact 24 4.5m 5.25m � � 14m + 14m �

Compact 28 3.4m 4.4m � � 14m + 14m �

Compact rear-flue 0.66m � � � � �

Compact 25HE 4.5m 5.5m 11.0m 12.0m 20m + 20m �

Compact 29HE 4.0m 5.0m 9.0m 10.0m 12m + 12m �

Compact 35HE 1.85m 2.85m 6.8m 7.8m 10m + 10m �

Linea 726 4.0m 4.8m 10.0m 10.8m 14m + 14m �

Linea 730 3.4m 4.2m 8.5m 9.3m 14m + 14m �

Linea 735 2.0m 2.8m 5.0m 5.8m 7m + 7m 7.8m + 7.8m �

Linea Max 1.8m 4.4m* � � 6m + 6m** �**Linea Max HE 2.0m 3.0m* � � 12m + 12m** �

Unica 28HE 7.8m 8.8m 20m 25m 40m + 40m �

Unica 32HE 7.8m 8.8m 20m 25m 35m + 35m �

Unica 36HE 7.8m 8.8m 20m 25m 35m + 35m �

Linea 25HE 7.8m 8.65m 20.0m 21.0m 40m + 40m �

Linea 30HE 7.8m 8.65m 20.0m 21.0m 65m + 65m �

Linea 35HE 7.8m 8.65m 20.0m 21.0m 50m + 50m �

Aquanova 2.4m 3.8m � � 7m + 7m �

Reductions for additional bend/s (reduction for PMK = 4.0 metres)45-deg 0.5m 1.0m 1.0m ** Notes90-deg 1.0m 1.0m 1.0m ** Notes

Max

imum

leng

th

Notes:Please refer to BS 5440 for specific details when installing an appliance to a SE-duct.A boiler top adaptor/kit is required when using the 80/125mm concentric & 80mm parallel systems.The Compact rear-flue cannot be used with additional bends and/or extensions.*The appliance flue elbow on the Linea Max cannot be used with a vertical flue application and should be discarded.**Contact Vokèra Technical Helpline for specific help and advice.

Horizontal & vertical concentric systems Horizontal & vertical parallel systems

Maximum length

Maximum length

Maximum length

Concentric60/100mm (4”)

Concentric80/125mm (5”)

Parallel (twin)80mm + 80mm

SE-DUCT(see notes)

Page 29: Prod Cat 06 - heatweb.com

Flue system

op

tions

subhead29

Flue system optionsintroduction

Notes:*Contact Vokèra Technical Helpline for specific help and advice**Please refer to BS 5440 for specific details when installing an appliance to a SE-Duct.A boiler top adaptor/kit is required when using the 80/125mm concentric & 80mm parallel systems.

Configuration Description Can be used with:

1 Horizontal concentric All appliances

2 Vertical concentric All appliances (Linea Max/Linea Max HE*)

3 Inverted concentric Linea 7-Series, Compact SE,

Mynute 24m, 28e, 35e and Rain

4 SE-Duct All Standard Efficiency (SE) appliances **

5 Horizontal parallel system All appliances

6 Vertical parallel system All appliances (Linea Max*)

Page 30: Prod Cat 06 - heatweb.com

PRODUCT FEATURES REFERENCE CHART

Pre-heated hot water � � � � �

Built-in frost protection � � � � �

Automatic by-pass � � � � �

Built-in filling loop � � � � �

Pre fixing jig � � � � �

Self-start feature � � � � �

Full hot water flame modulation +–1ºC max fluctuation � � � � �

Dry pump protection � � � � �

‘Anti-cycle’ heating control � � � � �

Electrical insulation to ‘IP4X’ � � � � �

Fault diagnostic display � � � � �

Telescopic flue system option � � � � �

Twin flue system option � � � � �

Vertical flue system option � � � � �

High efficiency air/gas modulation system � � � � �

Optional plug-in time control � � STD � �

Combustion test over-ride control � � � � �

Electronic burner ignition � � � � �

Pipe space through back of boiler OPT OPT OPT OPT OPT

Compartment ventilation not required � � � � �

Domestic heat exchanger: 5yr guarantee against scaling of DHW � � � � �

Optional pre-filling kit available � � � � �

LPG model available � � � � �

Expansion vessel, safety valve, pump built-in � � � � �

‘Dry loft’ option possible � � � � �

Automatic by-pass � � � � �

Self-start feature � � � � �

Dry pump run protection � � � � �

‘Anti-cycle’ heating control � � � � �

Fault diagnostic display � � � � �

Telescopic flue system option � � � � �

Twin flue system option � � � � �

Vertical flue system option � � � � �

High efficiency air-gas modulation system � � � 35e �

Optional plug-in time control � STD � � �

Electronic burner ignition � � � � �

Compartment ventilation not required � � � � �

LPG model available � � � � �

Fully modulating burner � � � � �

High Efficiency boilers

Standard Efficiency boilers

Linea HE

Linea 7-seriesLinea Max

(floor standing)Compact 24/28

Unica HE Compact HE

Mynute12e/16e/20e

Mynute28e/35e

Linea Max HE(floor standing)Mynute HE

Page 31: Prod Cat 06 - heatweb.com

Service and

trainingintroduction

31

Service and trainingintroduction�

Activ Service

We pride ourselves on providing a first class after sales servicewith 4 dedicated regional customer care centres and these aresupported with 32 factory trained Vokèra field engineers alongwith 85 service agents, which are able to support customersnationwide. The benefits include:-

• Every engineer carries a full complement of spare parts• Real time data field reports• Full monthly reports on all activities to the Installer or Contractor

highlighting all product and installation faults• One point of contact to report and discuss service issues• Full audit trail to track service calls

Technical Support

Our fully trained, CORGI registered technical team providespre-sales technical advice to help select the correct boiler, throughto post sales technical help to support the Installer.

Two Year Warranty

As with all domestic gas boilers, an annual service isrecommended to maintain optimum performance, efficiency andsafety. In addition to a Free 2 year warranty offered on everyVokèra boiler, we also make a promise to all our customers.

Our dedicated customer service team and CORGI registeredengineers are available 6 days a week to support the needs ofevery single Vokèra boiler installation. They respond to every callwithin 48 hours or less, or at a time agreed with the householder.They will make every effort to solve any technical problems overthe phone, answering quickly, politely and at all times acting in thebest interest of our customers.

Activ Training

Vokèra sets the standard for professionalism within the domesticheating industry with four regional training centres and elevenexternal training facilities across the United Kingdom and Eire. Courses available include the nationally-recognised City & GuildsCertificate in Energy Efficiency for Domestic Heating as well as acomprehensive range of product courses.Our product courses cover:-

• Key features of the boiler• General requirements • Technical data • Flueing • Installation • Commissioning • Fault finding • LPG Instructions • Servicing • Benchmark

View our course profiles at: www.vokera.co.uk orbook now: 0870 333 0220

Page 32: Prod Cat 06 - heatweb.com

Vokèra LtdBorderlake House, Unit 7 Riverside Industrial Estate, London Colney,Herts AL2 1HG

[email protected]

www.vokera.co.uk

Sales, General Enquiries: T 0870 333 0220F 01727 744004

Vokèra IrelandWest Court, Callan, Co KilkennyT 056 7755057F 056 7755060

Vokèra Limited reserve the right to change

specification without prior notice. Consumers

statutory rights are not affected.

A Riello Group Company.

Issue 3 06/06 bw1203