proceedings _ part ii _ collection of abstracts - 09-30-2015

118
1 Table of Contents Presentations Page Session I: Health Effects 2 Session II: Tests for and Diagnosis of Health Effects I 11 Session III: Vibration Measurement 26 Session IV: Vibration Reduction and Exposure Control 35 Poster Session 46 Session V: Characterization of Biodynamic Responses 53 Session VI: Computer Modeling and Analysis 66 Session VII: Combined Exposures and Health Effects 81 Session VIII: Risk Assessment and Epidemiology 90 Session IX: Tests for and Diagnosis of Health Effects II 101 Session X: Prevention, Intervention, and Training 108 Index of Authors 117

Upload: jordan-zimmerman

Post on 20-Jan-2017

196 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

1

Table of Contents

Presentations Page

Session I: Health Effects 2

Session II: Tests for and Diagnosis of Health Effects I 11

Session III: Vibration Measurement 26

Session IV: Vibration Reduction and Exposure Control 35

Poster Session 46

Session V: Characterization of Biodynamic Responses 53

Session VI: Computer Modeling and Analysis 66

Session VII: Combined Exposures and Health Effects 81

Session VIII: Risk Assessment and Epidemiology 90

Session IX: Tests for and Diagnosis of Health Effects II 101

Session X: Prevention, Intervention, and Training 108

Index of Authors 117

Page 2: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

2

Session I: Health Effects

Chair: Anthony Brammer and Ren Dong

Presenter Title and authors Page

Tohr Nilsson Keynote 1: Hand-arm vibration and the risk of vascular

and neurological diseases - a systematic review and meta-

analysis

Tohr Nilsson, Jens Wahlström, Lage Burström

3

Qingsong Chen The characteristics of vibration-induced white finger

among workers polishing handheld pieces in southern

china

Qingsong Chen, Bin Xiao, Aichu Yang, Hansheng Lin,

Hua Yan, Li Lang, Maosheng Yan, Guiping Chen,

Fansong Zeng, Xuqing Cao

5

Jordan Zimmerman Effects of power tool vibration duration on peripheral

nerve endings

Jordan Zimmerman, James Bain, Magnus Persson, Danny

Riley

7

Manman Gong Effects of occupational hand-transmitted vibration on

cardiovascular system: a meta-analysis

Manman Gong, Xiangrong Xu, Zhiwei Yuan, Rugang

Wang, Sheng Wang, Lihua He

9

Page 3: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

3

HAND-ARM VIBRATION AND THE RISK OF VASCULAR AND NEUROLOGICAL

DISEASES - A SYSTEMATIC REVIEW AND META-ANALYSIS

*Tohr Nilsson, Jens Wahlström, Lage Burström

Umeå University, Department of Public Health & Clinical Medicine, Occupational and

Environmental Medicine, SE-901 87, Umeå, Sweden

Introduction

Extensive and prolonged exposure to manual work involving the use of vibrating power

tools can lead to a number of pathological health effects primarily in the peripheral neurological,

vascular and musculoskeletal systems.1,2 The resulting symptom complex is now collectively

summarised and internationally acknowledged as the hand-arm-vibration syndrome or HAVS.

Knowledge of the relation between vibration exposure and the risk of injury is currently primarily

based on narrative summaries of separate scientific reports. Only for the vascular component

("white fingers") of HAVS, has a risk prediction modelling been presented in the annexe to ISO

5349.3 Neurosensory injury, carpal tunnel syndrome and musculoskeletal disorders all lack

separate risk prediction models regarding the hazard of vibration exposure. The following

systematic review of the scientific literature, with an accompanying statistical synthesis (meta-

analysis) attempts to specifically answer the question of how large is the possible risk of

developing an enhanced vasospasm ("Raynaud's phenomenon or" white finger ") or neurosensory

injury in relation to exposure to hand-transmitted vibration.

Methods

This systematic literature review with supporting statistical syntheses (meta-analyses) is

limited to hand-arm vibration exposure and vascular (“Raynaud’s phenomenon”) and nerve injury

(neurosensory disturbance). The review follows the "PRISMA statement" for reporting systematic

reviews and meta-analyses.4 The databases used for interrogation were PubMed and Science

Direct. The literature search covered publications from 1945 until September 31, 2014. The search

strategy used broad search criteria for both exposure and outcome. The eligibility criteria for

studies to be included in the final analysis were: Include measurements or estimates of vibration

exposure, Include the relevant health outcomes, Include only original data (not review), Aim to

study the risk of injury, Be published in English, and Study of health effects on humans. Two

independent reviewers performed the reviews following a pre set protocol for evaluation and

grading of methodological and scientific quality. Studies that reported a risk estimate (odds ratio)

for vascular or nerve injuries in relation to vibration exposure were eligible for the meta-analysis.

The statistical syntheses included random-effect meta-analysis with forest plots, meta-regression

and an analysis of possible influence from publication bias (funnel plots).

We found a total of 4325 abstracts, which all were read and whose validity and eligibility were

assessed according to the pre-established criteria. 293 articles were then examined in their entirety

to determine whether each article met all the inclusion criteria. From the 293 articles 241 were

excluded, which resulted in 52 articles that finally met the pre-established criteria for inclusion in

the systematic review.

Page 4: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

4

Results and Discussion

For the outcome Raynaud's phenomenon 41 articles were included in the final analysis. Of

these, 11 were cohort studies, two case-control studies and 28 cross-sectional studies. Studies with

low risk of bias (high quality) were found in all study designs. The articles were published between

1978 and 2013. For the 22 studies that allowed statistical synthesis 18 studies showed a significant

excess risk. The overall risk of vibration exposure for Raynaud’s phenomenon was more than four-

fold compared with unexposed. For the studies with “low risk of bias” the equivalent weighted

risk was almost seven-fold. Meta-regression analysis indicates a dose-response relationship for

Raynaud's phenomenon related to vibration exposure level.

For the outcome neurosensory injury, 33 articles were included of which 7 articles are

unique to the neurosensory injury only. 21 of the articles included also Raynaud's phenomenon

and 2 articles carpal tunnel syndrome. Of the total of 33 articles, 3 were cohort studies, three case-

control studies and 27 cross-sectional studies. 18 studies allowed statistical synthesis. The overall

risk of vibration exposure for neurosensory injury was more than four-fold compared with unexposed. For

the studies with “low risk of bias” the equivalent weighted risk was almost eight-fold. The funnel-

plot analysis indicates that the result might possibly be influenced by publication bias.

This systematic literature review with narrative synthesis and statistical synthesis of the

results consolidates that workers who are exposed to HAV have an increased risk of vascular and

neurological diseases compared to non-exposed groups. Conditioned the assumptions presented

the neurosensory injuries precedes the vascular damage.

References

1. Lawson I, Burke F, McGeoch K, Nilsson T, Proud G. Hand-arm vibration syndrome. In:

Baxter P, Aw T, Cockcroft A, Durrington P, Harrington J, editors. Hunters Diseases of

Occupations. 10th ed. London: Hodder Arnold; 2010. p. 489 -512.

2. Pelmear P, Wasserman D. Hand-Arm vibration: a comprehensive guide for occupational

health professionals. Second ed. Beverly Farms, MA: OEM Press; 1998.

3. ISO 5349-1. Mechanical vibration - Measurement and evaluation of human exposure to hand-

transmitted vibration - Part 1: General guidelines. Draft International Standard. Genevé,

Schweiz: International Organization for Standardization2001 May 1999.

4. Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gotzsche PC, Ioannidis JP, Clarke M,

Devereaux PJ, Kleijnen J, Moher D. The PRISMA statement for reporting systematic reviews

and meta-analyses of studies that evaluate health care interventions: explanation and

elaboration. Journal of clinical epidemiology. 2009 Oct;62(10):e1-34.

Page 5: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

5

THE CHARACTERISTICS OF VIBRATION-INDUCED WHITE FINGER AMONG

WORKERS POLISHING HANDHELD PIECES IN SOUTHERN CHINA

*Qingsong Chen, Bin Xiao, Aichu Yang, Hansheng Lin, Hua Yan, Li Lang, Maosheng Yan,

Guiping Chen, Fansong Zeng, Xuqing Cao

Guangdong Province Hospital for Occupational Disease Prevention and Treatment; Guangdong

Provincial Key Laboratory of Occupational Disease Prevention and Treatment, Guangzhou,

Guangdong 510300, China

Correspondence author: [email protected]

Introduction

Hand-transmitted vibration exposure, an important physical occupational hazard, may lead to

hand-arm vibration syndrome (HAVS)1. A typical vascular component of HAVS is vibration-

induced white finger (VWF). It is most frequently reported from the regions or countries with cold

climate. Southern China belongs subtropical region and VWF was rarely reported from such a

region before. However, such an occupational disease was also observed in Southern China recent

years, mostly among workers polishing handheld pieces in some hardware manufacture industries.

This study was designed to investigate the exposure and the characteristics of VWF among these

workers.

Methods

A total of 1,224 polishing workers from golf equipment factories were included in this study.

Of them, 147 VWF cases and 1,077 non-VWF cases (control group) were included. A

questionnaire was conducted regarding general demographic data, habits and customs,

occupational history, health status, etc. This questionnaire inquired about the frequency and extent

of VWF using the Griffin scoring system2. The acceleration of hand-transmitted vibration was

detected by a human vibration detection analyzer (SVANTEK106, Poland)3, and then the

cumulative vibration exposure level (CVEL) was calculated. The Chi square test was used to

analyze the distribution of VWF between the left and right hands. Factors associated with the

occurrence of VWF were screened through building a logistic regression equation with stepwise

backward method.

Results and Discussions

The median of 8 h energy-equivalent frequency-weighted acceleration was 5.54 m/s2 in the

workers. The median (interquartile range) time of vibration-exposure was 80.0 (34.0, 130.0)

months and 29.4% of the workers’ vibration-exposure length were over 10 years. The median

(interquartile range) CVEL was 57.29×103 (25.06×103, 93.82×103). As a result, 12.01% of

polishing workers reported varying degrees of VWF symptoms. In the case group, 137 cases were

recorded in detail with VWF. The incidence of blanching attacks of the thumb, index finger, middle

finger, ring finger, little finger were 21.7%, 88.4%, 58.0%, 17.4%, 8.0% in the left hand,

respectively, and 21.7%, 83.3%, 56.5%, 18.8%, 6.5% in the right hand. There was no significant

difference in the VWF distribution between the left and right hands (P>0.05). According to the

Griffin scoring system, the numbers of 1V, 2Ve, 2Vl, 3V, 4V were 28(20.4%), 32(23.4%),

44(32.1%), 33(24.1%), and 0(0%), respectively. When age, time of vibration-exposure, and

smoking and drinking habit were included into the logistic regression equation, the time of

Page 6: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

6

vibration-exposure was the most important factor the occurrence of VWF (OR 1.924, 95% CI

1.613-2.294, P<0.001); the average of the time of vibration exposure was 83.1±58.4 months in the

control group and 119.1±52.1 months in the case group (Z=8.60, P<0.001). With the increase of

time of exposure, the scores of HAVS became higher (Figure 1)

Figure 1: The dose-effect/response relationships

References

1. Heaver C, Goonetilleke KS, Ferguson H, Shiralkar S. Hand-arm vibration syndrome: a

common occupational hazard in industrialized countries. J Hand Surg Eur Vol 2011 2011-06-

01; 36(5):354-63.

2. International Organization for Standardization (2001) ISO5349-1. Mechanical vibration and

shock —Measurement and evaluation of human exposure to hand-transmitted vibration —Part

1: General requirements.

3. Griffin M. Handbook of Human Vibration. London: Academic Press, 1990; 1–988.

0

5

10

15

20

25

30

0

2

4

6

8

10

12

14

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Ave

rage

Sco

re

Pre

vale

nce

(%

)

Time(Year)

Prevalence

Average Score

Page 7: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

7

EFFECTS OF POWER TOOL VIBRATION DURATION ON PERIPHERAL NERVE

ENDINGS

*Jordan Zimmerman+, James Bain++, Magnus Persson+++, Danny Riley++

+Marquette University Biomedical Engineering

++The Medical College of Wisconsin Cell Biology, Neurobiology & Anatomy

+++Atlas Copco Tools

Introduction

Loss of peripheral nerve endings is seen in the fingers of workers who regularly use percussive, impact power

tools.1 Nerve degeneration is believed to contribute to the finger-numbing phenomenon in Hand Arm Vibration

Syndrome (HAVS). A similar loss of nerve endings has been replicated in a laboratory setting with the rat tail model.2

This model simulates a variety of tools generating shockwaves, including the riveting hammer and bucking bar. HAVS

occurrence has been directly correlated with length of exposure, as 50% of riveters with 10 or more years of exposure

exhibit HAVS.3 Although we have previously observed peripheral nerve damage after a single 12 min bout of

vibration, 12 minutes of exposure is considered a heavy workday. A common workday consists of 1 min/day

cumulative use of riveting tools.3 The present study used the rat tail model to examine the effects of 1, 6, and 12 min

single bouts of vibration on peripheral nerve endings.

Methods

Twelve female, 8 week-old Sprague Dawley rats were used in this study. 1, 6, and 12 minute bouts of

vibration exposure were delivered using the rat-tail model (n=3/time point). The animal protocol was approved by the

MCW IACUC. The riveting hammer setup of the rat-tail model was conserved, but a piezoelectric sensor was used as

a means of data collection rather than a laser vibrometer.3 MacroFiberComposite M8503-P2 piezoelectric sensors are

able to produce a voltage when experiencing a load. A single sensor was taped to the dorsum of the rat tail, and later

taped to the surface of the riveting hammer platform, in absence of the rat tail. From these data, the transmissibility

was calculated for 10 dominant frequencies observed in the riveting hammer signal. The frequencies of interest ranged

from 36 Hz to 16.3 kHz. Therefore, a sampling frequency of 75 kHz was chosen to abide by the Nyquist rate. The

animals recovered for 3.5 days to permit nerve injury to equilibrate before euthanasia and tissue acquisition. Cross-

sections were cut from decalcified tail segments 11 and 12 from non-vibrated control and vibrated test animals.

Quantitation of lanceolate mechanosensory nerve endings was conducted on PGP9.5 antibody-immunostained

nerves.2,5

Results and Discussion

The number of nerve ending processes per

lanceolate receptor complex was similar in the sham and

1 min vibrated rats (Fig. 1). The number of nerve endings

was significantly reduced for 12 min vibration, indicating

vibration-induced injury (Figs. 1, 2). Increasing duration

of vibration is more damaging based on the progressive

reduction in nerve endings.

Fig 1: Plot of the average number of nerve ending

processes per lanceolate mechanoreceptor (mean ± sem).

Page 8: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

8

Fig 2: The nerve ending processes of lanceolate mechanoreceptors

enwrap 3 hairs in the tail skin of a sham, non-vibrated rat (top panel).

The 12 min-vibrated rat exhibits a loss of integrity and reduced

number of nerve endings on 3 hairs (lower panel). Magnification bar

in top panel equals 63 µm.

Transmissibility was >1 for frequencies ≤ 3.9 kHz, whereas transmissibility was <1 for the 3 higher

frequencies (Table 1). Vibration magnitudes at 12.4 and 16.3 kHz were at least two orders of magnitude greater than

those at the other frequencies (Table 1). Larger transmissibility values (>1) may cause nerve damage to the tail through

properties of resonance, while lower transmissibility values (<1) may cause nerve damage via energy absorption,

presumably as high frequency shockwaves.

Table 1: The dominant frequencies and peak magnitudes are

listed for the vibration platform. Transmissibility at each

frequency represents the ratio of peak magnitude on the tail

divided by the magnitude on the vibration platform.

References

1. Takeuchi, T., Futatsuka, M., Imanishi, H., & Yamada, S. (1986). Pathological changes observed in the finger

biopsy of patients with vibration-induced white finger. Scandinavian Journal of Work, Environment and Health,

12(4), 280–283.

2. Raju, S. G., Rogness, O., Persson, M., Bain, J., & Riley, D. (2011). Vibration from a riveting hammer causes

severe nerve damage in the rat tail model. Muscle and Nerve, 44 (November), 795–804.

3. Dandanell, R., & Engstrom, K. (1986). Vibration from riveting tools in the frequency range 6 Hz - 10MHz and

Raynaud’s phenomenon. Scand J Work Environ Health 12, 338-342.

4. Xu XS, Riley DA, Persson M, Welcome DE, Krajnak K, Wu JZ, Govinda Raju SR and Dong RG. (2011)

Evaluation of anti-vibration effectiveness of glove materials using an animal model. Biomed Mater Eng 21:193-

211.

5. Li, L. and Ginty, DD. (2014) The structure and organization of lanceolate mechanosensory complexes at mouse

hair follicles. eLife 2014;3:e01901:1-24.

Page 9: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

9

EFFECTS OF OCCUPATIONAL HAND-TRANSMITTED VIBRATION ON

CARDIOVASCULAR SYSTEM: A META-ANALYSIS

*Manman Gong, Xiangrong Xu, Zhiwei Yuan, Rugang Wang, Sheng Wang, Lihua He

Peking University Health Science Center, Beijing, China

Corresponding author: HE Li-hua ([email protected])

Introduction

Many workers in several industrial sectors, especially in manufacturing and construction, are

exposed to Hand-transmitted Vibration (HTV), also known as Hand-arm Vibration or Segmental Vibration.

In the last few decades, the damage to their cardiovascular system caused by HTV has raised concern from

scholars both at home and abroad. However, conclusions drawn from different researches vary a lot with

large errors because of limitations of time, region, population and other factors. To improve statistical power

so as to ensure the reliability, this essay has conducted Meta-analyses based on large amounts of domestic

and overseas research findings about the effects of HTV on workers’ cardiovascular system. This essay is

aimed to obtain a more convincing conclusion which will provide fundamental data for precaution and

diagnosing.

Methods

Chinese literature retrieval database included CNKI, WanFang Data, VIP, and Sinomed. English

literature retrieval database included PubMed, EMBASE, The Cochrane Library, which were made before

June 2013. The Chinese key searching terms were divided into two groups. The first one included 手传振

动,手臂振动,局部振动 and the second group included: 白指,雷诺现象,手臂振动病,局部振动病,手臂振

动综合征,高血压,血压升高,心率,心电图,心血管. The English searching terms also had two groups. The

first group included: hand-transmitted vibration, hand-arm vibration, segmental vibration, and the second

group had white finger, Raynaud's phenomenon, hand-arm vibration syndrome, hand-arm vibration disease,

finger dermal temperature, hypertension, blood pressure, heart rate, electrocardiogram, and cardiovascular

system. Terms in each group were combined by “or”, while each group was combined by “and”.

Study type were all the cross-sectional surveys and retrospective cohort studies, including both

Chinese and English literatures, which describing the effects of HTV on cardiovascular system of workers.

And exposure group involved workers who exposed to HTV. Control group was consisted of non-exposed

workers, which was comparable with exposure group in age, working years, gender and other aspects.

Besides, reviews, news, and other non-original research were supposed to be excluded as well as repetitive

reports, irrelevant reports, brief reports. We should also exclude animal and cell experiments, non-original

data, non-occupational exposure literatures and etc.

This essay adapted the quality evaluation criteria recommended by Agency for Healthcare Research

and Quality. The researchers were well trained and the criteria were unified. All the tasks were conducted

respectively by every two researchers in parallel.

Software NoteExpress2 was used to manage literatures from search results. The literature excerpts

table was established in Excel 2007. RevMan5.2 was used to conduct pooled analysis and fractional analysis

based on heterogeneity selection model. The significance level was set to 0.05.

Results

This essay included fifty-five literatures. The quality evaluation criteria recommended by AHRQ

includes eleven items, which are supposed to be marked with “Yes”, “No” or “Uncertain”. The more items

with the mark “Yes”, the higher are the quality of literatures. Evaluated 51 pieces of literatures included, it

turned out that the number of “Yes” of each literature was more than five, which means the quality was

Page 10: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

10

good.

HTV could lead to hand-arm vibration syndrome (HAVS), which is a serious systemic disease

mainly with peripheral circulation disturbance. Individuals with HAVS typically showed vibration-induced

white finger as well as changes of blood pressure and ECG. Meta-analysis was carried out which based on

the prevalence data provided by all the research that has been done. Fixed effect model was adapted to

combine all the studies. The difference of prevalence of HAVS, VWF (Raynaud’s phenomenon of control

group) and hypertension between exposed group and control group was statistically significant (p<0.05).

The Meta-Analysis of effects of HTV on workers’ ECG showed that the difference of prevalence of sinus

arrhythmia, sinus bradycardia, conduction block, ST-T change was statistically significant (p<0.05), while

the difference of prevalence of premature beat and left ventricular hypertrophy had non statistical

significance (p≥0.05). According to the grouping analysis based on working years, the risk of suffering

from VWF increased with working years, but not obvious. And the prevalence rates were comparatively

higher in 3years~ group and 12years~ group. Also, the result indicated that no significant publication bias

was found in the Meta-Analysis and the significance to combined effects could be ignored.

Discussion

Population survey indicated long-term exposure to HTV would have an effect on cardiovascular

system with different symptoms. Before this essay, there have not been such studies that adapt Meta-

Analysis into the studies on effects of HTV on workers’ health. And we collect, select and evaluate all the

relevant studies to give comprehensive assessment about effects of occupational hand-transmitted vibration

on cardiovascular system.

Among all the indicators, the effect size of HAVS (RR=15.57) was the highest, while there was no

specific treatment currently. The patients would suffer from visible deformation joints and atrophy of hand

muscles, which would bring great pain and inconvenience to their daily work and life. Therefore, it is

indispensable to take effective measures to protect workers. The prevalence rates of VWF and hypertension

of exposed group were 2.86 and 2.92 times respectively as much as these of control group. When it came

to the effects of HTV on ECGs of workers, it was mainly shown that ST-T change, conduction block, sinus

bradycardia and sinus arrhythmia, while the difference of the prevalence rates of premature beat and left

ventricular hypertrophy had non statistical significance.

The prevalence of VWF was relevant to individual factors, vibration intensity, duration,

environment temperature and other factors. Exposed workers may have complex and various working

environment, change their occupations frequently, and use different kinds of vibration tools with different

intensity and duration which will affect the prevalence of VMF. Most of the current studies were carried

out among male workers. So grouping analysis cannot be conducted according to onset age or gender.

Compared with other occupational physical factors such as noise, the studies on effects of HTV

exposure on human body were quite few. So it is urgent to carry out comprehensive and in-depth studies.

In addition, the bias brought by cohort study cannot be completely avoided. However this essay collected

relevant literatures as far as possible through various methods and strived to control all kinds of bias. The

study results will provide fundamental data for precaution and diagnosis, as well as establishment of health

regulations.

Page 11: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

11

Session II: Tests for and Diagnosis of Health Effects I

Chairs: Noriaki Harada and Xueyuan Xu

Presenter Title and authors Page

Anthony J. Brammer Neuronal origin of vibrotactile perception thresholds at

the fingertips

Anthony J. Brammer

12

Mahbub Hossain Vibration-induced peripheral neuropathy: involvement of

fingers and diagnostic performance of vibrotactile

perception measurement revisited

Mahbub Hossain, Tatsuya Ishitake, Youichi Kurozawa,

Tsunehiko Takahashi, Norikuni Toibana, Ryosuke Hase,

Yoshinao Kawano, Noriaki Harada

14

Lars Gerhardsson Test-retest reliability of neurophysiological tests of hand-

arm vibration syndrome in vibration exposed workers and

unexposed referents

Lars Gerhardsson, Lennart Gillstrom, Mats Hagberg

16

Ron House Infrared thermography for the diagnosis of vascular

abnormalites in the hands and feet in hand-arm vibration

syndrome

R House, L Holness, I Taraschuk

18

Sandy P. Shiralkar Sole photographic evidence can be deceiving as a proof

of diagnosis in the medicolegal compensation claim to

confirm hand-arm vibration syndrome

Siobhan C. McKay, Sandy P. Shiralkar

20

Ying Ye Finger rewarming time in healthy men and women:

effects of room temperature and gender

Ying Ye, Michael J Griffin

22

Qingsong Chen Finger skin temperature during cold water immersion test

for diagnosing hand-arm vibration syndrome in different

climates in china

Bin Xiao, Danying Zhang, Aichu Yang, Guiping Chen,

Li Lang, Hansheng Lin, Xuqing Cao, Guoyong Xu,

Qingsong Chen

24

Page 12: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

12

NEURONAL ORIGIN OF VIBROTACTILE PERCEPTION THRESHOLDS

AT THE FINGERTIPS

*Anthony J. Brammer

Department of Medicine, University of Connecticut Health, Farmington, CT 06030, USA,

and Envir-O-Health Solutions, Ottawa, ON KIJ8W9, Canada

Introduction

Impaired tactile perception is a sensorineural symptom of the hand-arm vibration syndrome that is

associated with pathological neuronal deficits in the hands.1 Considerable progress has been made during

the last thirty years in understanding the neuronal responses mediating the sense of touch and their

relationships to vibrotactile perception.2-5 A combination of physiological and psychophysical studies on

humans has confirmed that tactile perception at the fingertips depends on activity in four populations of

specialized nerve endings. These are commonly described by their responses to skin indentation as: SAI -

slowly adapting type I, SAII - slowly adapting type II, FAI - fast adapting type I, and FAII - fast adapting

type II mechanoreceptors. The SAI mechanoreceptors are primarily responsible for resolving large scale

features of a surface, such as ridges or edges, while the FAI and FAII populations are primarily responsible

for resolving small scale features (e.g., surface texture), and detecting the movement of objects in contact

with the skin. SAII mechanoreceptors signal skin stretch, and their role in vibrotactile perception, if any,

remains unclear.

An early observation was the similarity between the vibrotactile perception thresholds (VPTs)

recorded when the fingertips were stimulated by sinusoidal vibration at selected frequencies and neuronal

activity in the most sensitive mechanoreceptor units at these frequencies.4,5 The purpose of this paper is to

extend the analysis of neuronal activity and VPTs to derive a numerical estimate for the onset of sustained

neuronal activity at the fingertips, and compare this to the results of a psychophysical study designed to

identify different channels of vibrotactile perception using apparatus compatible with ISO 13091-1.6,7

Methods The nerve fiber action potentials generated by single mechanoreceptor units at the fingertips of

alert human subjects in response to sinusoidal vibration have been reported by Johansson and co-workers.3

From these data, contours expressing the vibration acceleration at which the mean single-unit response was

one action potential per two stimulus cycles have been constructed as a function of frequency. An estimate

for the onset of sustained neuronal activity in different mechanoreceptor populations is then obtained by

adjusting the FAI and SAI single-unit contours by the mean population densities of these receptors relative

to that of the FAII receptors at the fingertips, using the results of Vallbo and Johannson.2 No adjustment is

made to the FAII single-unit contour.

In addition, a psychophysical experiment has been performed in which human subjects are

presented a pure-tone conditioning vibration stimulus at 31.5 Hz or 200 Hz, at 20 dB above the perception

threshold (i.e., 20 dB sensation level, SL), while VPTs are determined successively at 4 and 200 Hz, or at

4 and 31.5 Hz, during the 31.5 or 200 Hz conditioning stimulus, respectively. The apparatus complied with

method A of ISO 13091-1,6 and was conducted with the palm and fingers fully supported and facing

upwards, a 3 mm diameter, flat-ended circular stimulator, and a contact force of 0.04 N. Subjects gave their

informed consent to participate in the study, which had received ethics committee approval.

Results and Discussion

The estimate for the onset of sustained neuronal activity, which is taken here to correspond to the

onset of sensation at a given frequency, is shown in Figure 1.

Page 13: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

13

Conditioning

Stimulus

Mean Threshold Shift

± Standard Deviation (dB)

Freq.

(Hz)

SL

(dB)

4 Hz 31.5 Hz 200 Hz

31.5

20 -1.6

±2.9

NA 1.4

±6.0

200

20 -0.8

±1.8

0.9

±2.5

NA

Table1: Mean threshold shift (± standard deviation)

Figure 1: Neuronal estimate for the onset of sensation in response to a 20 dB SL pure-tone conditioning

for different mechanoreceptor populations vibration stimulus (NA- not applicable)

The contours suggest that at stimulus frequencies from 3 to 5 Hz, the most sensitive

mechanoreceptor population will be the SAI receptors, which consequently appear most likely to mediate

the VPTs at these frequencies with suitably defined conditions of stimulation. Similarly, at the other

frequencies prescribed by ISO 13091-1, the FAIs may be expected to mediate the VPTs from 20 to 31.5

Hz, and the FAIIs from 100 to 160 Hz.

The results of the psychophysical experiment are shown in Table 1. The mean threshold shifts at 4

and 200 Hz, or 4 and 31.5 Hz, are found to be insignificantly different from zero for each conditioning

stimulus. Now Verrillo and Gescheider have shown a conditioning stimulus elevates the VPT equally at all

frequencies mediated by that psychophysical channel.7 Hence, the results of this experiment confirm that

VPTs at 4, 31.5 and 200 Hz when stimulated in the manner specified by ISO 13091-1 are mediated by

different mechanoreceptor populations, as would be expected from the neuronal estimates for the onset of

sensation in Figure 1. Confirmation of the existence of different psychophysical channels mediating VPTs

at these frequencies is also provided by masking,8 and temporary threshold shift,5 paradigms. Reference

again to Figure 1 reveals another property of mechanoreceptor populations that has been confirmed by

psychophysical studies,8 namely with more intense stimulation at a given frequency, a second (or third)

“threshold” mediated by a different receptor population can be obtained.

References 1. Takeuchi, T., Futatsuka, M., Imanishi, H., and Yamada, S. (1986). Pathological changes observed in the finger

biopsy of patients with vibration-induced white finger. Scand. J. Work Environ. Health, 12, 280-283. 2. Vallbo Å.B., and Johannson, R.S. (1984). Properties of cutaneous mechanoreceptors in the human hand related

to touch sensation. Human Neurobiol., 3, 3-14. 3. Johannson, R.S., Landström, U., and Lundström, R. (1982). Responses of mechanoreceptive afferent units in the

glabrous skin in the human hand to sinusoidal skin displacements. Brain Res., 244, 17-25. 4. Löfvenberg, J., and Johansson, R.S. (1984). Regional differences and interindividual variability in sensitivity to

vibration in the glabrous skin of the human hand. Brain Res., 301, 65-72. 5. Lundström, R., and Johannson, R.S. (1986). Acute impairment of the sensitivity of skin mechanoreceptive units

caused by vibration exposure of the hand. Ergonomics, 29, 687-698. 6. ISO 19091-1 (2001). Mechanical Vibration - Vibrotactile perception thresholds for the assessment of nerve

dysfunction - Part 1: Methods of measurement at the fingertips. International Organization for Standardization, Geneva.

7. Verrillo, R.T., and Gescheider, G.A. (1972). Effect of prior stimulation on vibrotactile thresholds. Sensory Processes, 1, 292-300.

8. Gescheider, G.A., Bolanowski, S.J., Pope, J.V., and Verrillo, R.T. (2002). A four-channel analysis of the tactile

sensitivity of the fingertip: Frequency selectivity, spatial summation, and temporal summation. Somatosensory

Motor Res., 19, 114-124.

Page 14: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

14

VIBRATION-INDUCED PERIPHERAL NEUROPATHY: INVOLVEMENT OF

FINGERS AND DIAGNOSTIC PERFORMANCE OF VIBROTACTILE PERCEPTION

MEASUREMENT REVISITED

*Mahbub Hossain+, Tatsuya Ishitake++, Youichi Kurozawa+++, Tsunehiko Takahashi++++, Norikuni

Toibana+++++, Ryosuke Hase+, Yoshinao Kawano+, Noriaki Harada+

+Department of Hygiene, Yamaguchi University Graduate School of Medicine, Ube, Japan ++Department of Environmental Medicine, Kurume University School of Medicine, Kurume, Japan

+++Department of Social Medicine, Faculty of Medicine, Tottori University, Yonago, Japan ++++Kaetsu Hospital, Niigata, Japan

+++++Kensei-Ishii Clinic, Tokushima Japan

Introduction

Peripheral neuropathy in hand-arm vibration syndrome (HAVS) may involve multiple sites of the

upper extremity. Vascular and neurological components of HAVS appear to occur and progress

independently1; the apparent sparing of thumb in vascular component of HAVS may not be so in

neurological component of it. However, in published literature, there is a lack of studies that compared the

involvement of the thumb and other fingers affected by peripheral neuropathy among patients with HAVS.

Also, the diagnostic significance of such involvement of the thumb in HAVS is not clear. Therefore, the

purpose of this study was to investigate this issue and compare the diagnostic value of measurement of

vibrotactile perception threshold (VPT) at the thumb and other fingers in diagnosing peripheral neuropathy

in HAVS.

Methods

A total of 61 HAVS patients and 62 control subjects from eastern and western regions of Japan

underwent a personal interview and various tests on two different days. Vibrotactile perception threshold

(VPT) was measured at every fingertip of the test hand (worst-affected hand for the patients and dominant

hand for the controls) at three frequencies‒ 4 Hz, 31.5 Hz and 125 Hz, by a commercial vibrometer (HVLab

Tactile Vibrometer, University Southampton, UK), in accordance with the ISO 13091-12. VPT data from

36 patients and 37 control subjects could be included in the final analysis. The values of the VPT data were

transformed to dB (relative 10−6 ms−2). The group differences between two-related samples were analyzed

using Wilcoxon signed-ranks test with Bonferroni corrections for multiple comparisons when appropriate.

The diagnostic performance of the test was evaluated with the receiver operating characteristic (ROC) curve

analysis and areas under the ROC curve (AUC) for each finger at each test frequency, and the following

were calculated: sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV),

positive likelihood ratio (LR+), and negative likelihood ratio (LR−). Statistical analysis was performed with

2 statistical softwares: Medcalc version 10.0.2 (MedCalc Software, Mariakerke, Belgium) and IBM SPSS

Statistics for Windows, version 22.0 (IBM Corp, Armonk, NY). Statistical significance was considered at

a two-sided P<0.05.

Results and Discussions

Compared to age-matched control subjects, as in all other fingers, VPT of the thumb was

significantly higher among the patients at all test frequencies (P<0.05 to 0.005; Wilcoxon signed-ranks

test); the differences were larger at 31.5 Hz and 125 Hz. Overall, the VPT at all fingers increased as the test

frequency increased. Across different test frequencies, at a specificity of 80%, the values obtained for the

Page 15: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

15

thumb ranged between 50.0% to 83.3% for sensitivity, 72.0% to 81.1% for PV+, 62.5% to 83.3% for PV-,

2.6 to 4.4 for LR+, and 0.6 to 0.2 for LR- ; the values for the other fingers ranged between 41.7 to 88.9%,

68.2% to 82.9%, 58.8% to 88.2%, 2.2 to 5.0, and 0.1 to 0.7 for sensitivity, PV+, PV-, LR+, and LR-,

respectively (table 1). Under each test frequency, the value of AUC for the thumb did not significantly

differ from the corresponding values for other fingers. Compared with the corresponding values of AUC at

4 Hz, the values of AUC were significantly larger for all fingers at 31.5 Hz (P<0.05 to 0.005; Wilcoxon

signed-ranks test), and for middle, ring and little fingers at 125 Hz (P<0.05 to 0.005; Wilcoxon signed-

ranks test). The values of AUC did not significantly differ between 31.5 Hz and 125 Hz. In this study, the

observed values of sensitivity, specificity, PPV, NPV, LR+ and LR−, and AUC indicate the effectiveness of

mechanoreceptor-specific VPT measurement in all fingers including the thumb in the diagnosis of

peripheral neuropathy in HAVS. A number of previous studies investigated the diagnostic value of VPT

measurements at different fingers in distinguishing patients with neurological HAVS3-5; however, none of

those studies investigated the thumb for that purpose which makes any comparison of the current study

findings at the thumb with those of the other fingers difficult. However, the current findings are consistent

with those from the previous studies because a higher specificity was accompanied by a relatively lower

sensitivity for all of the investigated fingers. Overall, this matched case–control study demonstrated

comparable diagnostic performance of VPT measurement at the thumb and at other fingers by the ISO-

standardized test method, for detection of peripheral neuropathy in HAVS. However, clinical, diagnostic

and prognostic importance of thumb involvement in neurological HAVS needs to be clarified further.

Table 1 Diagnostic performance of VPT test with the corresponding cut-off value for different fingers at different

test-frequencies

At 80% Thumb Index Middle Ring Little

specificity 4 Hz 31.5 Hz 125 Hz 4 Hz 31.5 Hz 125 Hz 4 Hz 31.5 Hz 125 Hz 4 Hz 31.5 Hz 125 Hz 4 Hz 31.5 Hz 125 Hz

Sensitivity (%) 50.0 83.3 63.9 41.7 75.0 75.0 47.2 80.6 75.0 41.7 88.9 80.6 52.8 80.6 80.6

PV+ (%) 72.0 81.1 76.7 68.2 79.4 79.4 70.8 82.9 79.4 71.4 82.1 80.6 73.1 80.6 80.6

PV- (%) 62.5 83.3 69.8 58.8 76.9 76.9 61.2 81.6 76.9 59.6 88.2 81.1 63.8 81.1 81.1

LR+ 2.6 4.4 3.4 2.2 4.0 4.0 2.5 5.0 4.0 2.6 4.7 4.3 2.8 4.3 4.3

LR- 0.6 0.2 0.5 0.7 0.3 0.3 0.7 0.2 0.3 0.7 0.1 0.2 0.6 0.2 0.2

Cut-off (dB) >89.8 >107.5 >122.8 >90.1 >107.6 >119.1 >91.6 >108.9 >120.8 >92.0 >107.8 >124.2 >92.5 >110.9 >125.8

References

1. Pelmear, P.L. (2003). The clinical assessment of hand-arm vibration syndrome. Occupational Medicine-Oxford

53: 337-341.

2. ISO 13091-1. Mechanical vibration—vibrotactile perception thresholds for the assessment of nerve

dysfunction—Part 1: Methods of measurement at the fingertips. Geneva, Switzerland; International Organization

for Standardization, 2001.

3. Ekenvall, L., Gemne, G., and Tegner, R. (1989). Correspondence between neurological symptoms and outcome

of quantitative sensory testing in the hand-arm vibration syndrome. British Journal of Industrial Medicine 46:

570-574.

4. Virokannas, H. (1992) Vibration perception thresholds in workers exposed to vibration. Int Arch Occup Environ

Health 64: 377-382.

5. Wenemark, M., Lundström, R., Hagberg, M., and Nilsson, T. (1996) Vibrotactile perception thresholds as

determined by two different devices in a working population. Scand J Work Environ Health 22: 204-210.

Page 16: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

16

TEST-RETEST RELIABILITY OF

NEUROPHYSIOLOGICAL TESTS OF HAND-ARM VIBRATION SYNDROME

IN VIBRATION EXPOSED WORKERS AND UNEXPOSED REFERENTS

*Lars Gerhardsson, Lennart Gillstrom, Mats Hagberg

Occupational and Environmental Medicine, University of Gothenburg

Box 414, SE-405 30 Gothenburg, Sweden

Company Health Service, Volvo Powertrain Corporation, SE-541 36 Skovde, Sweden

Introduction

Exposure to hand-held vibrating tools may cause hand-arm vibration syndrome (HAVS)

including vibration white fingers, sensorineural symptoms and musculoskeletal disturbances.1 A

dose-response relationship has been observed between the development of sensorineural

symptoms and the level of cumulative exposure to hand-arm vibration in metalworkers.2

Quantitative sensory testing (QST) can be used to measure the sensory nerve function

noninvasively.3 Several sensory modalities may be affected by vibration exposure, which

contribute to an alteration of touch, vibration, warmth, cold and pain perception. QST has been

found to be fairly reproducible over a period of days or weeks in normal subjects.3 The aim of the

investigation was to study the test-retest reliability of hand and muscle strength tests, and tests for

the determination of thermal and vibration perception thresholds, which are often used when

investigating signs of neuropathy in vibration exposed workers.

Methods

In this study, 47 vibration-exposed workers (36 males and 11 females) who had been

investigated by the department of Occupational and Environmental Medicine in Gothenburg were

compared with a randomized sample of 18 unexposed subjects from the general population of the

city of Gothenburg. The mean age in the vibration-exposed group was 50.4 ± 12.4 y (median

exposure time 16 y) compared to 37.6 ± 15.9 y in the reference group. All participants passed a

structured interview, answered several questionnaires and were subject to a physical examination

that included hand and finger muscle strength tests and determination of vibrotactile (VPT) and

thermal perception thresholds (TPT). The participants were asked to avoid vibration exposure

during the day of the measurements and to refrain from use of tobacco and coffee/tea for at least

one hour before the start of testing. Two weeks later, 23 workers and referents, selected in a

randomized manner, were called back for the same test-procedures for the evaluation of test-retest

reliability.

Results and Discussions

The test-retest reliability after a two week interval expressed as limits of agreement (LOA;

Bland-Altman), intra-class correlation coefficients (ICC) and Pearson correlation coefficients was

excellent for tests with the Baseline hand grip, Pinch-grip and 3-Chuck grip among the exposed

workers and referents (N=23: percentage of differences within LOA 91 – 100 %; ICC-values ≥

0.93; Pearson’s r ≥ 0.93). The test-retest reliability was also excellent (percentage of differences

within LOA 96-100 %) not only for the determination of vibration perception thresholds in digits

Page 17: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

17

2 and 5 bilaterally but also for temperature perception thresholds in digits 2 and 5 bilaterally

(percentage of differences within LOA 91 – 96 %). For ICC and Pearson’s r, although the results

for vibration perception thresholds were good for digit 2 of the left hand and for digit 5 of both

hands (ICC≥0.84; r ≥0.85), the results were lower (ICC=0.59; r=0.59) for digit 2 of the right hand.

For the latter two indices the test-retest reliability for the determination of temperature thresholds

was lower and showed more varying results.

The main findings show excellent to very good test-retest reliabilities for tests of Baseline

hand grip, Pinch grip and 3-Chuck grip as well as for the determination of vibration perception

thresholds through vibrometry. Compared to the other tests, the test-retest reliability for the

determination of temperature perception thresholds was lower with a wider spread. For TPT

determinations, LOA gave considerably higher test-retest reliability than ICC and Pearson (r).

For the diagnosis of vibration-caused neuropathy, no individual test has shown a superior

sensitivity and specificity in the assessment of its severity. Thus, multiple tests and clinical

assessments (bed-side diagnostics, e.g. needle, tuning fork, 2-PD and monofilament tests) are

needed to accurately judge and grade the sensorineural component of HAVS.4 Whether it is

sufficient with one trial or if multiple testing should be recommended to group the results for a

greater reliability of the values obtained, still needs to be investigated.

Previous studies have indicated that the reproducibility of determination of thermal

thresholds may not be as good as the determination of vibration perception thresholds. This is

reflected in our study by lower test-retest reliability for ICC and Pearson’s r, although, the

percentage of differences within LOA still remained high. The determination of temperature

perception thresholds may thus be more susceptible to the methodology used, duration of testing

and time interval between tests.3

The determination of vibration or temperature perception thresholds is relatively

complicated and time-consuming. The person that administrates the test needs to be experienced

and able to see if the subject fully understands and cooperates with the instructions. For some

subjects, the results may somewhat improve after 2-3 trials; however, due to mainly economic

reasons and time constraints, there is often only one trial per subject.

The strong test-retest reliability (repeatability) for hand and muscle strength tests as well

as for the determination of VPTs makes these procedures useful for diagnostic purposes and

follow-up studies in vibration-exposed workers.

References

1. Gemne, G. (1997). Diagnostics of hand-arm system disorders in workers who use vibrating tools.

Occup. Environ. Med. 54(2): 90-95.

2. Sauni, R., Paakkonen, R., Virtema, P., Toppila, E. and Uitti, J. (2009). Dose-response relationship

between exposure to hand-arm vibration and health effects among metalworkers. Ann. Occup. Hyg.

53(1): 55-62.

3. Chong, P.S. and Cros, D.P. (2004). Technology literature review: quantitative sensory testing. Muscle

Nerve 29(5): 734-747.

4. Heaver, C., Goonetilleke, K.S., Ferguson, H. and Shiralkar, S. (2011). Hand-arm vibration syndrome:

a common occupational hazard in industrialized countries. J. Hand. Surg. (Eur Vol) 36E(5): 354-363.

Page 18: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

18

INFRARED THERMOGRAPHY FOR THE DIAGNOSIS OF VASCULAR

ABNORMALITES IN THE HANDS AND FEET IN HAND-ARM VIBRATION

SYNDROME

*R House+, L Holness+, I Taraschuk++

+St. Michael’s Hospital, Toronto, Ontario, Canada ++Workplace Safety and Insurance Board, Toronto, Ontario, Canada

Introduction

The traditional tests used for the diagnosis of the vascular component of HAVS (a form of

secondary Raynaud’s phenomenon), including digital thermometry and plethysmography, have not been

found to perform well in terms of sensitivity and specificity.1 Thermography, using an infrared (IR) camera,

provides a thermal image allowing simultaneous measurement of any part of the area imaged and this has

the potential for the development of an improved diagnostic test for vascular HAVS. There is evidence to

suggest that workers who develop vascular HAVS in their hands may also develop similar problems in their

feet2 and these putative effects might also be investigated by thermography of the feet. This study

investigated IR thermography as a diagnostic test for the vascular component of HAVS in the hands using

the ISO recommended cold water test parameters (12◦ C and 5 minutes of immersion)3 to determine the best

finger location, time period of re-warming and cut-off point for a positive test to maximize test performance

in terms of sensitivity and specificity. A similar investigation of the feet was done to determine the presence

of temperature differences in workers with HAVS in comparison to controls and to assess the performance

of thermography as a diagnostic test in the feet.

Methods

HAVS cases were recruited at an occupational health clinic in a teaching hospital affiliated with

the University of Toronto. Controls, with no history of Raynaud’s phenomenon, were recruited principally

from hospital and university employees. A total of 39 HAVS cases and 46 controls participated in the study.

The participants had their right hand immersed in water of 12◦ C for 5 minutes followed by measurement

of finger temperature during a re-warming period of 15 minutes. The temperatures were measured on the

ventral surface of each finger at the midpoints of the fingertips, middle phalanges and proximal phalanges.

Initial evaluation of re-warming curves indicated similar re-warming of all the fingers but not the thumb.

Therefore the four finger temperatures were averaged at each of the three finger locations. The temperatures

were compared in the cases and controls at each minute of re-warming from 0 to 15 minutes and regression

modeling was used to compare the temperatures of cases and controls over the entire 15 minute re-warming

period. The temperature data were further evaluated using a Receiver Operating Characteristic (ROC)

analysis. At each finger location the time period of re-warming with the highest area under the curve (AUC)

was chosen for calculation of sensitivity and specificity at multiple cut-off points spanning the temperature

range of subjects. In the evaluation of feet effects, 33 of the 39 HAVS cases reported cold intolerance in

their feet and therefore these 33 cases were used for comparison with the controls. The right foot was

immersed in water of 12◦ C for 5 minutes, followed by measurement of toe tip temperature each minute

during a 15 minute re-warming period. The initial rewarming curves were similar for all 5 toes and therefore

the analysis was done for each toe and the average of all 5 toes. The analysis of the feet data was similar to

the analysis of the hand data.

Page 19: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

19

Results and Discussions

The re-warming curves indicated greater differences between cases and controls for the hands than

the feet throughout the 15 minutes of re-warming. In the analysis of the hand data, the regression modeling

indicated statistically significant differences in temperature between cases and controls throughout the re-

warming period. The greatest AUC occurred at 7 minutes of re-warming at each finger location. However

at this re-warming time the overall test performance was not optimal, with sensitivities of slightly above

80% being associated with specificities below 50%, as summarized in Table 1.

Table 1. Summary of ROC Analysis for Various Finger Locations (Average Temperatures of Digits 2-5)

Location Re-warming Time

with Highest AUC

AUC

(p value)

Sensitivity/ Specificity at Various Cut-off Points for a

Positive Test at Each Location

Sensitivity Specificity

Finger Tips 7 minutes 0.715

(p=0.002)

43.6

66.7

82.1

80.4

60.9

45.7

Middle Phalanges 7 minutes 0.719

(p=0.001)

43.6

66.7

82.1

80.4

60.9

43.5

Proximal

Phalanges

7 minutes 0.708

(p=0.002)

46.2

66.7

82.1

80.4

67.4

41.3

In the feet data, the regression analysis did not show any statistically significant temperature

differences between cases and controls modeled over the entire 15 minutes. The re-warming curves did

indicate that the temperature differences increased as re-warming progressed and therefore the temperature

differences between cases and controls were explored in more detail for each toe and the average of all toes

at each time period of re-warming. None of the temperature differences was statistically significant (p<0.05)

until the 12th minute of re-warming. Statistically significant temperature differences between cases and

controls were seen for the 3rd and 5th toes at 12, 13, 14 and 15 minutes of re-warming and for the average

of all toes at 15 minutes of re-warming. In the AUC analysis the thermography of the feet performed more

poorly, in terms of sensitivity and specificity, than the thermography of the hands (results not shown).

In summary, the IR thermography of the hands did not perform well as a diagnostic test for the

vascular component of HAVS. In the feet, although the regression analysis did not show statistically

significant temperature differences between cases and controls modeled over the entire 15 minute re-

warming period, there were statistically differences towards the end of re-warming. These findings do

suggest subtle vascular feet effects in HAVS subjects consistent with previous research.2 Future research

on thermography should evaluate re-warming beyond 15 minutes because the temperature differences did

appear to be increasing, especially in the feet, as the re-warming progressed.

References

1. Mahbub MH, Harada N. (2011). Review of different quantification methods for the diagnosis of digital vascular

abnormalities in hand-arm vibration syndrome. J Occup Health 53(4):241-49.

2. House R, Jiang D, Thompson A, Eger T, Krajnak K, Sauve J, Schweigert M. (2011).Vasospasm in the feet in

workers assessed for HAVS. Occup Med (Lond) 61(2):115-120.

3. ISO 14835-1 (2005). Mechanical vibration and shock – Cold provocation tests for the assessment of peripheral

vascular function – Part 1: Measurement and evaluation of finger skin temperature. International Organization

for Standardization, ISO, Geneva, Switzerland.

Page 20: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

20

SOLE PHOTOGRAPHIC EVIDENCE CAN BE DECEIVING

AS A PROOF OF DIAGNOSIS IN THE MEDICOLEGAL COMPENSATION CLAIM

TO CONFIRM HAND-ARM VIBRATION SYNDROME

Siobhan C. McKay, *Sandy P. Shiralkar

The Department of Vascular Surgery, The Dudley Group NHS Foundation Trust

Dudley DY1 2HQ, West Midlands, United Kingdom

Introduction

Hand Arm Vibration Syndrome (HAVS) is a significant cause of disability worldwide, with a

prevalence of 288,000 sufferers in the UK alone in 19981. In addition to being a disabling condition for

sufferers, it is a significant cause of litigation and compensation settlement for employers. The diagnosis of

HAVS is heavily dependent on self-reporting of symptoms2. Whilst sufferers must be compensated, there

is a growing concern from employers that false claims are being lodged for monetary gains. It has been

concluded that a presenting history of Raynaud's syndrome in workers seeking compensation for HAVS

may not be accurate since approximately half the cases (43%) are unable to provide objective photographic

evidence of Raynaud's phenomenon3. For the accurate diagnosis of vascular symptoms and to confirm

HAVS, most Defendants’ experts ask for and greatly rely upon a photographic evidence revealing classical

Raynaud’s syndrome of hands.

We conducted a survey of doctors who would potentially assess HAVS patients; to investigate the

possibility of inaccurate diagnosis of Raynaud’s and subsequently HAVS based on a digitally altered

photograph.

Methods

A photograph of a normal patient’s hands

was altered digitally using Photoshop (Adobe, USA)

to show sharp demarcation with white discoloration

of the right distal two phalanges of the index and

middle fingers (Figure 1). This digital alteration was

performed within a very short period of time without

much technical support. An online survey based on the

altered photograph was sent to 48 UK consultants from

various specialities who within their clinical practice

would potentially assess patients with HAVS. This

included ten Vascular surgeons; nine Plastic hand

surgeons, ten Orthopaedic hand surgeons; ten

Rheumatologists; and nine Occupational health

physicians. The survey consisted of three clinical

questions related to the photograph and three responder

demographic questions.

Figure 1: A 48 year old man presents to outpatient

clinic with complaints of fingers turning white

especially in cold weather. He has brought a

photograph of his hands.

Please provide your spot diagnosis of this condition.

Page 21: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

21

Results and Discussion

The current survey response rate was 54% (26 of 48 surveyed). This included four Vascular

surgeons, six Orthopaedic hand surgeons, four Plastic hand surgeons, eight Rheumatologists and four

Occupational health physicians. The number of years of experience within their specialty ranged from six

to 30 years, with a median of 15 years.

In the question provided; a history of vibration exposure was avoided to eliminate the bias. The

photograph demonstrated unilateral blanching attack thus excluding primary Raynaud’s phenomenon.

All 100% experts’ spot diagnosis was Raynaud’s; out of which 81% of responders (21 of 26)

directly responded Raynaud’s as their main spot diagnosis. The rest five sub-diagnosis were - HAVS in

12% (3 of 26); Raynaud’s or HAVS in 4% (1 of 26); and embolism in 4% (1 of 26).

Table 1: What is your differential diagnosis which is causing this condition?

Raynaud’s – 21 (81%) HAVS – 3 (21%)

Raynaud’s or HAVS – 1 (4%)

Embolic – 1 (4%)

None 0

In this survey 100% of expert responders agreed to the diagnosis of Raynaud’s in their primary spot

diagnosis. A comprehensive differential diagnosis were proposed by all except one respondent which

included – Buerger’s disease; connective tissue disease e.g. scleroderma, lupus, rheumatoid; drug related

e.g. vasospasm secondary to beta-blockers; vasculitis; MS; para-neoplastic; cryoglbulinaemia; thoracic

outlet syndrome; hyperviscosity e.g. in polycythaemia or leukaemia; hyperfibrogenaemia; cold agglutinins;

porphyria; arterial thrombosis (subclavian/ radial) - thromboembolism; surgical implants etc.

HAVS is a diagnosis of exclusion, once primary Raynaud’s and other causes for secondary

Raynaud’s have been excluded. Raynaud's is a vascular manifestation of HAVS and is typically diagnosed

by a subjective history provided by employees/ Claimants. In this survey, none of the 26 experts indicated

any suspicion or doubt about the validity /authenticity of the photograph and all arrived at the diagnosis of

Raynaud’s syndrome.

This survey demonstrates that an easily altered photograph can convincingly appear to demonstrate

Raynaud’s; which is a vascular component of HAVS. Therefore in conclusion, just a photographic evidence

cannot be profoundly relied upon to agree/ confirm the diagnostic of HAVS.

References

1. Palmer, K.T., Coggon, D.N., Bendall, H.E., Kellingray, S.D., Pannett, B., Griffin, M.J., and Harward,

B.M. (1999). Hand-transmitted vibration: occupational exposures and their health effects in Great

Britain. Health and Safety Executive, United Kingdom.

2. Poole, K. (2009). A review of the literature published since 2004 with potential relevance in the

diagnosis of HAVS. Health and Safety Executive, United Kingdom.

3. Sami Youakim (2008). The validity of Raynaud's phenomenon symptoms in HAVS cases. Occup Med

(Lond) 58 (6):431-435.

Page 22: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

22

FINGER REWARMING TIME IN HEALTHY MEN AND WOMEN: EFFECTS OF

ROOM TEMPERATURE AND GENDER

*Ying Ye and Michael J Griffin

Human Factors Research Unit, Institute of Sound and Vibration Research, University of

Southampton, Southampton SO17 1BJ, England

Introduction

Vibration-induced white finger (VWF) is the vascular component of the hand-arm

vibration syndrome (HAVS). International standard 14835:2005 defines two tests to assist the

diagnosis of VWF: the measurement of finger rewarming time and the measurement of finger

systolic blood pressures.1 It has been suggested that the diagnostic value of the finger rewarming

test depends on environmental conditions.2,3 This study investigated the effects of both room

temperature and gender on the finger rewarming test. It was hypothesised that with increased room

temperature finger rewarming time would decrease. Women were expected to have lower initial

finger skin temperatures (FSTs) and longer rewarming time than men.

Methods

Twelve men and twelve women with a mean

age of 24.3 years (SD: 3.1; range: 18-30) participated

in two sessions. Before the test started, subjects were

in one of two room temperatures (20 or 28°C) for at

least 30 minutes or until they had a constant FST

(<1ºC variation over 10 minutes). Finger rewarming

was measured by an experimenter experienced in

applying the test according to the recommended

procedure.1,4

An HVLab 8-channel temperature monitor

(University of Southampton) measured finger

temperatures (Fig. 1). Thermocouples were attached

to the palmar surfaces of the distal phalanges of the

thumb, index, ring, and little fingers, and the distal,

median, and proximal phalanges of the middle finger

of the right hand. The hand was covered by a thin loose waterproof glove. After a resting period

of 2 minutes, the right hand was immersed in stirred water at 15°C for 5 minutes. The hand was

then removed from the water with the help of the experimenter, the glove was removed, and the

hand remained motionless while rewarming over 40 minutes. The skin temperature was monitored

continuously during the settling period, the cooling period, and the rewarming period using a

computer and HVLab diagnostic software (version 8.5, University of Southampton).

Results and Discussion

Median finger skin temperatures on the distal phalanx of the right hand before, during, and

after cold provocation with room temperatures of 20 and 28°C are shown for males and females

in Fig. 2.

Fig. 1: Immersion of a gloved right hand in

stirred water at 15 °C.

Page 23: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

23

During the 2-minute

resting period, FSTs were

higher in the higher room

temperature in both men and

women (p < 0.01). The FSTs

during this period were lower

in women than in men at both

room temperatures (p < 0.001).

During the 5-minute

cooling period, there was

greater reduction in FSTs with

the higher room temperature in

both men and women (p <

0.001). The reduction in FST

was greater in men than in

women (p < 0.05).

During the first 8

minutes of the recovery period,

the median FST increased at

3.2°C/min in men and 2.0°C/min in women with the 28°C room temperature, but at only 1.8°C in

men and 1.7°C/min in women with the 20°C room temperature. Subsequently, the median FSTs

show steady rewarming with the 28°C room temperature, but with the room temperature at 20°C

the rate of increase in median FST decreased to 0.1°C/min in men over a 3-minute period and in

women over an 7-minute period. Thereafter, the rate of increase in median FST remained at 1.0-

1.2°C/min until the median FST recovered to the initial temperature. The time for individual FSTs

to return to within 2°C of the initial finger temperature was shorter with the higher room

temperature in both men and women (p < 0.01), and shorter in men than in women at both room

temperatures (p < 0.001).

The results show that increased environmental temperature shortens rewarming time and

that men have shorter rewarming time than women. Variation in the rate of rewarming with a 20°C

room temperature suggests vasodilation during recovery is not mediated solely by gradual release

of arterial vasospasm but through a combination of processes.5

The study shows that room temperature affects the accuracy of the finger rewarming test,

and that a criterion for normal rewarming time developed for men will not apply to women.

References

1. International Organization for Standardization (2005) Mechanical vibration and shock – cold provocation tests

for the assessment of peripheral vascular function – Part 1: Measurement and evaluation of finger skin

temperature. International Standard, ISO 14835-1.

2. Bovenzi M (1987) Finger thermometry in the assessment of subjects with vibration-induced white finger. Scand

J Work Environ Health 13: 348-351.

3. Virokannas H and Rintamäki H (1991) Finger blood pressure and rewarming rate for screening and diagnosis of

Raynaud’s Phenomenon in workers exposed to vibration. Br J Ind Med 48: 480-484.

4. Lindsell C and Griffin MJ (1998) Standardised Diagnostic Methods for Assessing Components of the Hand–Arm

Vibration Syndrome, CRR 197/1998, Sudbury, Suffolk: HSE Books, 1–87.

5. Lindsell C and Griffin MJ (2001) Interpretation of the finger skin temperature response to cold provocation. Int

Arch Occup Environ Health 74:325–335.

Fig. 2: Median finger skin temperatures before, during, and after

immersion of the hand in stirred water at 15 °C.

0

5

10

15

20

25

30

35

40

0 5 10 15 20 25 30 35 40 45 50

Male: 28 C

Female: 28 C

Male: 20 C

Female: 20 C

Time (minutes)

Recovery periodF

ing

er

skin

tem

pera

ture

( C

)

Resti

ng

peri

od

Co

oli

ng

peri

od

Page 24: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

24

FINGER SKIN TEMPERATURE DURING COLD WATER IMMERSION TEST

FOR DIAGNOSING HAND-ARM VIBRATION SYNDROME

IN DIFFERENT CLIMATES IN CHINA

Bin Xiao, Danying Zhang, Aichu Yang, Guiping Chen, Li Lang, Hansheng Lin,

Xuqing Cao, Guoyong Xu, *Qingsong Chen

Guangdong Province Hospital for Occupational Disease Prevention and Treatment; Guangdong

Provincial Key Laboratory of Occupational Disease Prevention and Treatment, Guangzhou,

Guangdong 510300, China

Correspondence to: [email protected]

Introduction

Finger skin temperature (FST) during immersion testing has been proposed as a useful

method for diagnosing hand-arm vibration syndrome (HAVS)1,2. FST is widely used in temperate

environments; however, few studies of the use of FST during immersion testing in subtropical

environments have been performed. This study aimed to assess the differences in FST values

during immersion testing (10°C, 10 min) in temperate versus subtropical environments in China

for the purposes of diagnosing HAVS.

Methods

Two groups of subjects were involved in this study: 100 workers from Guangdong province

(subtropical environment, group A) and 99 workers from Shandong province (temperate

environment, group B). Both groups were initially divided into three subgroups: HAVS, vibration-

exposed controls (VEC), and non-vibration-exposed controls (NVEC)1,3. Cold water immersion

testing was performed on all subjects during the winter, in which individuals immersed their hands

in 10°C water for 10 min after a 30-minute break. The FST of the ring finger of the dominant hand

was measured every 5 min by an infrared thermometer before and after testing. The FST at 0, 5,

10, and 30 min after testing (T0, T5, T10, and T30) and rewarming rate at 5 and 10 min after testing

(R5 and R10) were determined. An ANOVA was used to analyze differences between groups. The

sensitivity and specificity of statistically different results were analyzed between patients and

control subjects using ROC curves.

Results and Discussions

For group A, there were no statistically significant differences found for baseline temperature,

T0, T5, T10, R5, or R10 among the three subgroups. The only statistically significant difference

in this group was observed at T30 (Table 1). For group B, no statistically significant differences

were observed for baseline temperature, T0, R5, or R10 among the three subgroups. The T5, T10,

and T30 of the HAVS group were significantly lower than those of the other subgroups (Table 1).

In addition, the ROC areas (95%CI) of T5 and T10 in group B were 0.759(0.644, 0.874, P<0.01)

and 0.757(0.639, 0.875, P<0.01), respectively (Figure 1). This study demonstrated that the cold

water immersion test (10℃, 10 min) has excellent value in supporting the clinical diagnosis of

HAVS in temperate environments. In addition, T5 may also be a good indicator of diagnosis.

However, FST did not appear to be useful for diagnosing HAVS in a subtropical environment.

Page 25: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

25

Table 1. Temperature differences before and after cold water immersion testing in different

groups.

Group A,

( n=100)

Group B

( n=99)

NVEC

(n=37)

VEC

( n=37)

HAVS

( n=26)

NVEC

( n=37)

VEC

( n=42)

HAVS

( n=20)

Pre, °C 27.6±4.4 28.5±4.3 27.9±4.6 27.6±4.4 28.8±4.2 26.2±4.5

T0, °C 12.0±1.5 11.3±1.5 11.8±1.6 11.7±1.2 11.9±1.1 11.2±1.2

T5, °C 16.3±3.2 15.1±1.5 15.0±3.8 16.2±3.4 17.4±3.5 14.0±2.1*#

T10, °C 19.8±5.0 18.6±3.2 18.6±6.1 19.9±5.9 21.6±5.3 16.4±3.6*#

T30, °C 24.0±5.0 27.3±4.7* 24.4±7.4 24.8±5.6 27.9±5.0 22.7±5.6#

R5, % 27.2±14.9 23.4±10.4 18.3±17.6 27.6±16.0 28.8±16.2 19.2±9.9

R10, % 48.8±23.8 43.4±17.1 39.5±28.1 49.5±27.4 50.9±28.8 35.7±20.7

* compared with NVEC, p<0.05;# compared with VEC, p<0.05

References

1. Laskar S, Harada N. Different conditions of cold water immersion test for diagnosing hand-arm

vibration syndrome. Environmental Health and Preventive Medicine, 2005, 10(6): 351-359.

2. National Occupational Health Standard in China(GBZ7-2014)(2014):Diagnostic Criteria of

Occupational Hand-Arm Vibration Disease.Ministry of Public Health,Beijing.

3. Poole K, Elms J, Mason H. Modification of the Stockholm vascular scale. Occupational Medicine,

2006, 56(6): 422-425.

Figure 1: The ROC curves of T5 and T10 for diagnosis HAVS in Group A and Group B

Page 26: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

26

Session III: Vibration Measurement

Chairs: Tammy Eger and Enrico Marchetti

Presenter Title and authors Page

Ren G. Dong Hand-arm coordinate systems for measuring vibration

exposure, biodynamic responses, and hand forces

Ren G. Dong, Erik W. Sinsel, Daniel E. Welcome,

Christopher Warren, Xueyan S. Xu, Thomas W.

McDowell, John Z. Wu

27

Uwe Kaulbars Determining the measurement uncertainty of workplace

measurements conforming to GUM

Uwe Kaulbars

29

David Rempel Comparison of handle vibration for hammer drills using a

new test bench system

David Rempel, Alan Barr, Andrea Antonucci

31

Krishna Dewangan Evaluations of low-cost resistive sensors for

measurements of hand forces on vibrating handles

Subhash Rakheja, Pierre Marcotte, Krishna Dewangan,

M. Kalra

33

Page 27: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

27

HAND-ARM COORDINATE SYSTEMS FOR MEASURING VIBRATION EXPOSURE,

BIODYNAMIC RESPONSES, AND HAND FORCES

*Ren G. Dong, Erik W. Sinsel, Daniel E. Welcome, Christopher Warren,

Xueyan S. Xu, Thomas W. McDowell, John Z. Wu

Engineering and Control Technology Branch, Health Effects Laboratory Division,

National Institute for Occupational Safety & Health, Morgantown, WV, USA

Introduction

Two types of hand coordinate systems for measuring vibration exposures and biodynamic

responses have been standardized in ISO 8727 (1997)1 and ISO 5349-1 (2001)2. They are termed as

basicentric (BC) and biodynamic (BD) coordinate systems, respectively. They are different from those

actually used in tool testing standards and biodynamic measurements, which casts doubt on their suitability

and usefulness. The objectives of this study were to identify the major sources of the problems and to help

define or identify better coordinate systems.

Methods

This study systematically reviewed and clarified the principles and definitions of the BC and BD

coordinate systems. Several typical hand and arm coordinate systems (Figure 1) were evaluated. The typical

working postures of the hand and arm during the operation of more than 15 types of powered hand tools,

together with conventional postures used in hand-arm vibration laboratory experiments, were considered in

the review and evaluation. The relationships (γ and β angles) among BD coordinate systems shown in

Figure 1(b) were also measured. 20 subjects participated in the experiment. The results were used to

enhance the evaluation and to estimate the principal grip force in these BD systems.

Figure 1: Various hand and arm coordinate systems

(a) Basicentric coordinate systems: the ISO system (h-BC)

illustrated in the figure of the standards1,2; the ISO

system (ISO-BC) interpreted from the written

definition in ISO 87271; the BC system recommended

in ISO 28927 (BC)3; and BS EN system (EN)4.

(b) Biodynamic coordinate systems: the standard

BD system (h-BD)1,2; the forearm-based BD

system (Forearm); the thenar region-based BD

system (Thenar)5; and the metacarpal joint

head-based BD system (MJH)6.

Page 28: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

28

Results and Discussion

This study confirms that it is reasonable to define two types of coordinate systems for studying

hand-transmitted vibration, as accelerometers remain the most convenient and effective technology for

measuring vibration exposures and biodynamic responses. While the basicentric coordinate system is

primarily defined for guiding the installation of the accelerometer on a handle to measure vibration

exposures, the biodynamic coordinate system is defined primarily for describing, measuring, and analyzing

hand and arm postures and biodynamic responses. The standard BC system is neither clearly defined nor

correctly illustrated in the current standards1,2; as a result, it is interpreted differently in some other standards

and in reported studies. For example, the ISO-BC system we interpreted from the written definition included

in ISO 8727 is different from the standard illustration, as shown in Figure 1(a). The tool-specific BC system

(BC system) recommended in ISO 28927 (2009-2012)3 is consistent with the written definition except for

the swapping of the x and z axes. Furthermore, the zBC axis on a non-right-angle tool handle should not be

required to be fully aligned with the functional or action direction of the tool, as the alignment of the yBC

axis with the handle axis cannot make the zBC axis fully in line with the action direction of such a tool. The

BS EN system4 is also reasonable if its xEN axis refers to the dominant vibration direction.

Multiple BD coordinate systems are actually required to describe the postures of the hand and arms

and to measure the biodynamic responses and hand forces. It is neither necessary nor convenient to define

the BD system based on the bony anatomy principle adopted in ISO 87271 or ISO 5349-12, as such a

principle is actually not suitable to the study of hand-arm vibration exposures or biodynamic responses.

Although the standardized hand BD system (h-BD system in Figure 1(b)) is claimed to be precisely defined

based on the bony anatomy principle, this system is not convenient, and it does not have any unique

biological basis or biodynamic foundation. For these reasons, its usefulness is very limited. In contrast, the

thenar region-based BD system initiated from our previous study is much more meaningful, convenient,

and implementable5. The forearm-based coordinate system is also a useful BD system. The MJH system

was used to measure grip force6. It can also be used in the study of vibration, but it is not a convenient

system and it varies with handle size. The relationships among the BD systems identified in this study

suggest that the principal direction of grip force is approximately correlated with the index fingertip location

on cylindrical handles. When the principal grip force is of concern, the index fingertip-based coordinate

system should be considered to perform the measurement.

References

1. ISO 8727. Mechanical vibration and shock - Human exposure-Biodynamic coordinate systems. International

Organization for Standardization, Geneva, Switzerland, 1997.

2. ISO 5349-1: Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted

vibration - Part 1: General requirements. International Organization for Standardization, Geneva, Switzerland,

2001.

3. ISO 28927 (from Part 1 to Part 12): Hand-held portable power tools -- Test methods for evaluation of vibration

emission. International Organization for Standardization, Geneva, Switzerland, 2009-2012.

4. BS EN 60745-1. Hand-held motor-operated electric tools. Safety. General requirements. British Standards

Institution, 2009.

5. Dong R.G., Welcome D.E., Warren C., Dong C.L., McDowell T.W., Wu J.Z., A novel theory: ellipse of grip

force. Proceedings of the 1st American Conference on Human Vibration, Morgantown, WV, June 2006.

6. Edgren, C.S., Radwin, R.G., Irwin, C.B., 2004. Grip force vectors for varying handle diameters and hand sizes.

Human Factors 46 (2): 244-251.

Page 29: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

29

DETERMINING THE MEASUREMENT UNCERTAINTY OF WORKPLACE

MEASUREMENTS CONFORMING TO GUM

Uwe Kaulbars

IFA – Institute for Occupational Safety and Health of the German Statutory

Accident Insurance – (IFA, formerly BGIA), Alte Heerstrasse 111, 53757 Sankt Augustin

Introduction

For an assessment of the reliability of measurement results, it is essential that

measurements are correctly performed and that the measurement uncertainty is known. To obtain

information on the quality of the measurement results from different laboratories, knowledge of

the measurement uncertainty is required even in the case of standardised and "error-free"

measurements. This becomes increasingly important when measured data are supplied to databases

from different sources. More precise calculations of the measurement uncertainty are also required

for the validation of hazard analyses and for vibration reduction forecasts and programmes.

A uniform guide for different measurement quantities has been available for 20 years in

the shape of the Guide to the Expression of Uncertainty in Measurement (GUM)1. Since it has not

so far been applied to the field of human vibration exposure owing to the unacceptably high

complexity of the task, DIN SPEC 45660-22 has been produced in Germany.

This technical report contains examples of the measurement uncertainty of vibration

exposure calculated from activity-related measurements to ISO 5349-23. The guide values of the

measurement uncertainty contributions used are based among other things on an inter-laboratory

test organised by IFA. The goal of the test was to determine the measurement uncertainty for

standardised measurements.

Methods

To ensure the same conditions for the duration of the

inter-laboratory test, a fictitious workplace was set up for three

tasks to be performed by two experienced workers. The tasks

consisted of cutting square tubes with a pneumatic angle grinder,

drilling dowel holes with an electric rotary hammer and cutting

contours in glulam worktops with an electric jig saw (see Fig.

1).

Seven laboratories accredited to ISO/IEC 170254 took

part in the inter-laboratory test. Each laboratory carried out its measurements independently on a

separate day. To ensure uniformity, new tools and materials were used on each day of measurement

and the proceedings were monitored by an independent observer. To compare the series of

measurements, additional control tasks were carried out with a calibrator for three fixed

frequencies and amplitudes.

Results and Discussions

Each laboratory evaluated its own data and conducted a risk assessment. All the data were

evaluated by the neutral Institute for Proficiency Tests (IfEP) in conformity with ISO/IEC 170435,

ISO 135286 and ISO 5725-27.

Fig. 1: Measurement tasks

Page 30: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

30

The calculation model for measurement uncertainty to DIN SPEC 45660-22 is based on the

main uncertainty contributions presented in Table 1. The laboratory standard deviation 𝑢𝑀 is

obtained with the following equation:

𝑢𝑀 = √ 𝑢𝑀𝑒𝑎𝑠𝑢𝑟𝑖𝑛𝑔 𝑖𝑛𝑠𝑡𝑟𝑢𝑚𝑒𝑛𝑡2 + 𝑢𝐶𝑜𝑢𝑝𝑙𝑖𝑛𝑔

2 + 𝑢𝑆𝑒𝑛𝑠𝑜𝑟 𝑝𝑜𝑠𝑖𝑡𝑖𝑜𝑛2

To validate the

calculation model conforming

to DIN SPEC 45660, the

measurement uncertainties of

the respective overall vibration

values are calculated in

accordance with EUROLAB

TR 1/20068 and compared. The

results from the two models

were largely identical, although

the EUROLAB model tended to

show higher values. In addition,

the trueness and precision of all

measurement results were

determined and the reprodu-

cibility, repeatability and

laboratory standard uncertainty

were calculated.

Table 1: Orientation values of the measurement uncertainty contributions DIN

SPEC 45660

The inaccuracy data of all the measuring instruments are based on the supplements to measuring

instrumentation standard ISO 80419.

References

1. ENV 13005 Guide to the expression of uncertainty in measurement GUM

2. DIN SPEC 45660-2 Guide for dealing with uncertainty in acoustics and vibration – Part 2: Uncertainty of

vibration quantities

3. ISO 5349-2(2001) Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted

vibration - Part 1: General requirements, Part 2: Practical guidance for measurement at the workplace

4. ISO/IEC 17025(2005) General requirements for the competence of testing and calibration laboratories

5. ISO/IEC 17043(2010) Conformity assessment - General requirements for proficiency testing

6. ISO 13528(2005) Statistical methods for use in proficiency testing by interlaboratory comparisons

7. ISO 5725-2(1994) Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method

for the determination of repeatability and reproducibility of a standard measurement method

8. EUROLAB Technical Reports 1/2006, Guide to the Evaluation of Measurement Uncertainty for Quantitative Test

Results

9. ISO 8041 Human response to vibration - Measuring instrumentation, Amendment (2015)

Acknowledgements

Our thanks go to the Institute for Proficiency Tests (IfEP), Marl, Germany, and to the participating laboratories: German

Social Accident Insurance Institution for the woodworking and metalworking industries, German Social Accident

Insurance Institution for the raw materials and chemical industry, Ingenierbüro Gillmeister, Brandenburg's Land

laboratory, Müller BBM GmbH, SLG Prüf- und Zertifizierungs GmbH.

Page 31: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

31

EVALUATION OF HANDLE VIBRATION FOR HAMMER DRILLS

USING A NEW TEST BENCH SYSTEM

*David Rempel, Alan Barr, Andrea Antonucci

Ergonomics Graduate Training Program, Department of Bioengineering,

University of California, Berkeley, CA, USA

Introduction

Drilling holes into concrete is a common task in commercial construction required for placing anchor bolts

that support pipes, conduit, ducts or machinery or for setting rebar (e.g., dowel and rod drilling) for structural retrofits,

seismic upgrades or extending roads and tarmacs. The typical handle vibration levels for this work are 8-16 m/s² for

hammer drills and 14-20 m/s² for pneumatic rock drills (Griffin 2006).

Test bench methods have been developed for evaluating silica dust from cement cutting tools (Akbar-

Khanzadeh 2010) but not for handle vibration using concrete drills and there are no international standards for such

test bench systems. Instead, international standards call for handle vibration to be measured in controlled settings

while workers use the drill (ISO 28927- 6&10). There is a concern that a test bench may constrain the system in ways

that will alter handle vibration as compared to vibration experienced by workers. The purpose of this project was to

develop and evaluate an automated test bench system in order to evaluate drill handle vibration under different

conditions of concrete drilling.

Methods

A test bench system was designed and built with the following features: (1) automatically controls an active

drill and advances it into concrete under force control, (2) automatically advances concrete blocks between holes, (3)

accommodates a wide variety of drill types, and (4) continuously records handle vibration. The drill is firmly coupled

to a saddle that is moved horizontally by a linear actuator under force control (e.g., feed force (FA) = weight on bit

(WOB)) managed by a custom LabView program on a PC. The drill is secured to the saddle with ring clamps at the

drill handle; between the clamps and the drill a 1 cm thick rubber/foam is inserted with stiffness properties similar to

palmar skin. The activated drill drills into a concrete block to a specified depth (up to 250 mm) at a constant feed force

(adjustable range: 50 and 500 N) and is automatically withdrawn. After each hole is drilled the concrete block is

advanced so that the next hole can be drilled. The drill saddle is coupled to a single axis load cell with a stiff spring

aligned to the drilling axis (Figure 1). The load cell is moved by the linear actuator on a lathe bed. Non-reinforced

concrete blocks (3.5 x 12 x 12”) are made with quality is consistent with reinforced structural concrete (slump 80 mm;

EN 206-1:2000).

A tri-axial accelerometer (Larson Davis HVM100) was attached to the drill handle using hose clamps and

the signal was sampled at 1Hz and stored to a computer. The accelerometer and load cell were calibrated prior to use

(PCB Piezotronics shaker 394C06). Tool handle vibration acceleration magnitude was measured and interpreted

according to ISO standards (ISO 28927-6&10).

Figure 1. Mechanical model of system with linear actuator (left), stiff spring (k1, c1), load cell and drill saddle

(m1), drill mount (mass), rubber interface (k2, m2, c2), and drill (a).

Page 32: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

32

Validation of the test bench system was assessed by comparing test bench results to those from 4 experienced

construction workers drilling 5 holes per test condition, following ISO methods. Subjects signed a written consent

form and the study was approved by the University Committee on Human Research. Subjects drilled vertically into

concrete block to measure thrust force while subjects stood on an electronic force plate (Sampling rate 25Hz; Acculab

Digital Scale, Bradford, MA). The workers were instructed to apply thrust force similar to their usual drilling. Handle

vibration measurements were similar to measurement on the test bench system.

Four test conditions were evaluated on the test bench: two electric hammer drills (TE40 and TE7, Hilti), each

with a 3/8 and 3/4" concrete bit. For each condition, 5 holes were drilled to 125 mm (ISO 28927-10) with a target

linear force of 90N. Two test conditions were evaluated by the human studies: the same two electric hammer drills

with the 3/8” bit. Human testing was not done with the 3/4” bit. Productivity was measured as drilling time to

complete drilling depth.

Results and Discussion

Summary measures of findings (mean (SD)) are presented in the Table below.

Drill Bit Holes

Linear Force

(N)

Drilling

Time (s)

Mean Peak

Vibration (m/s²)

Mean Mean

Vibration (m/s²)

TEST BENCH

TE40 3/4" 21 90.2 (3.8) 32.7 (1.4) 17.0 (2.0) 7.2 (0.5)

TE7 3/4" 16 89.7 (1.8) 78.8 (4.0) 29.1 (1.6) 9.0 (0.3)

TE40 3/8" 11 73.3 (4.3) 13.5 (0.6) 16.2 (2.1) 7.1 (1.1)

TE7 3/8" 22 88.5 (9.5) 15.2 (1.1) 31.1 (0.6) 9.5 (0.2)

HUMAN TESTING (N=4)

TE40 3/8" 5 74.6 (4.1) 24.4 (1.6) 7.9 (1.0)

TE7 3/8" 5 81.6 (23.0) 31.5 (5.3) 10.1 (1.0)

Linear force for the test bench was close to target values of 90N with low variance for the ¾” bit. The 3/8”

bit was undersized for the TE40 leading to difficulty maintaining constant feed force. The self-selected linear force

by workers was somewhat less than the force used for the test bench. As expected, the coefficient of variance (CV)

for linear force for the workers was higher (0.05 to 0.28) than the test bench (0.02 and 0.11).

Mean vibration levels were similar between the test bench and the human testing. Mean peak vibration levels

were similar for the small drill but not the large drill.

The test bench system included foam rubber damping at the coupling to the drill handle designed to be similar

to the palm coupling. In addition, a stiff spring isolated the drill from the linear actuator, mimicking the role of the

forearm and upper arm. It appears that the masses of the saddle and load cell provided a response that was similar to

the human system (Dong 2010). Future validation studies should involve larger bits (e.g., 5/8” and 3/4”) that are more

appropriate for the drills tested.

The test bench methods differ from the ISO standard in several ways. The ISO standard calls for drilling

downward, but when drilling downward with an electric hammer drill, the bit will bind in a 250 mm depth hole because

there is no air flushing of the dust. So drilling on the test bench was done horizontally to prevent bit binding. In

addition, the ISO standard calls for subjects do the drilling. This may lead to handle grip force and force on tip that

are similar to work. However, this approach is also associated with increased variance in measures while the robotic

system minimizes variance. The problem of robotic system not matching real world grip and feed force can be

addressed by having the robotic system perform testing under different feed force and grip force levels. This approach

may provide greater insights into drill design and vibration and may influence instructions to end-users. A test bench

system for concrete drilling can provide information that compliments data from human compliance testing.

References

1. Dong R, Rakheja S, McDowell T, Welcome D, Wu J. Estimation of the Biodynamic Responses Distributed at

Fingers and Palm Based on the Total Response of the Hand-Arm System. Int J Ind Ergon 2010; 40(4): 425-436.

2. ISO 28927-10 (2011): Hand-held portable power tools – test method for evaluation of vibration emission – Part

10: Percussive drills, hammers and breakers. Geneva: International Organization for Standardization, Geneva.

Page 33: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

33

EVALUATIONS OF LOW-COST RESISTIVE SENSORS FOR MEASUREMENTS OF

HAND FORCES ON VIBRATING HANDLES

Subhash Rakheja+, Pierre Marcotte++, *Krishna Dewangan+++, M. Kalra+

+Concave Research Centre, Concordia University, Montreal, QC, Canada ++IRSST, Montreal, QC, Canada

+++North Eastern Regional Institute of Science & Technology, Nirjuli, India

Introduction

The hand-handle coupling force, often considered as the summation of the grip and push

forces, permits the flow of vibration energy from the tool into the palm of the hand and arm. The

coupling force thus directly affects the nature of hand transmitted vibration (HTV) and hand-arm

biodynamics. Although the significance of coupling force with regard to quantifying the hand-arm

vibration (HAV) exposure has been widely recognized, the measurements of hand forces on

vibrating tools have met only limited success due to lack of a reliable measurement system and

definite relations between the static coupling force and HTV. Lemerle et al. [1] explored a

capacitive pressure sensing matrix to measure push and grip forces on power tools. The

measurement system, however, is not considered well-suited for field applications due to its very

high cost, while its validity for measuring dynamic forces in frequency ranges of power tools has

not been demonstrated. In this study, low-cost resistive sensors (FlexiForce) are evaluated for

measuring hand forces on a percussion tool handle under stationary and vibration conditions. The

feasibility of the sensor is also evaluated for measuring biodynamic responses of the hand-arm

system.

Methods

The experiments were initially conducted to assess applicability of

low-cost resistive sensors (FlexiForce) for measurements of hand forces on

a chipping hammer positioned in an energy dissipater and hand-arm

biodynamic responses using 3 and 6 subjects, respectively. Two sensors

were applied on the top and bottom surfaces of the primary tool handle for

measurements of palm and finger forces (Fig. 1), which were used to

estimate hand grip and push forces, as described in [2]. Each subject stood

on a force plate nearly upright and gripped the tool handle in a power grip

manner. The static sensitivity of each sensor was evaluated for each subject

over the 150 N force range through calibrations. The validity of the

measurements was evaluated, while subjects grasped the stationary tool

handle with 5 different combinations of grip and push forces.

Measurements were repeated while the subject operated the tool. The force plate and finger-side

sensor signals were displayed to the subject to apply controlled forces, while the palm sensor signal

was hidden from the subject. The correlations between the push force estimated from FlexiForce

sensors and force plate output, and between palm sensor force and the coupling force were

evaluated under both stationary and vibrating conditions.

In the second experiment, two FlexiForce sensors were applied symmetrically about the

center line of a 38 mm diameter instrumented handle along the forearm-axis for measuring the

Palm sensor

Finger sensor

Fig.1: FlexiForce sensors

applied to tool handle

Page 34: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

34

hand-arm biodynamic response. The palm and finger-side forces were acquired under different

combinations of hand grip and push forces, and two levels of broadband random vibration in the

4–1000 Hz range (frequency-weighted rms acceleration: 1.5 and 3 m/s2). The force signal from

the instrumented handle was analyzed to obtain the reference biodynamic responses in terms of

driving-point mechanical impedance (DPMI). The palm and finger FlexiForce sensors signals

were analyzed to compute the palm- and fingers-side DPMI responses. Each measurement was

repeated twice. The data were acquired for a duration of 20 s during each measurement. A

frequency correction function, derived from the frequency response of the sensors, was applied to

compensate for limited bandwidth of the sensors, as described in [3]. The validity of the FlexiForce

sensors for measuring biodynamic response was assessed through comparisons with the reference

DPMI responses under different vibration and hand forces considered.

Results and Discussions

Figure 2(a) illustrates correlations of push force estimated from FlexiForce sensors with

those obtained from the force plate for the 3 subjects operating the power tool (r2: 0.82–0.95).

Very good correlations were also obtained between the palm sensor measurements and the

coupling force (r2: 0.93–0.98). The ratio of push force obtained from FlexiForce sensors to force

plate signal ranged from 0.94–1.08 for the three subjects, while that of the palm force to the

coupling force ranged from 0.96–1.05. The results further showed good repeatability of sensors

applied to the tool handle. Figures 2(b) and 2(c) compare the corrected and uncorrected palm and

finger DPMI magnitudes obtained from FlexiForce sensors with the reference responses from the

instrumented handle under 3 m/s2 excitation (grip/push forces: 30/50 N). The results show that

corrected responses from the sensors agree well with the reference values. The uncorrected

responses of the sensors, however, resulted in substantially lower DPMI magnitudes, although

these show good trends. This was attributed to the limited frequency response of the sensors.

Fig. 2: Correlations of push force data obtained from FlexiForce sensors and force plate for each

subject grasping the vibrating tool handle (a); and comparisons of corrected and uncorrected

palm (b) and finger (c) impedance responses with the reference responses

References

1. Lemerle P, Klinger A, Cristalli A, Geuder M, 2008. Application of pressure mapping techniques to measure push

and gripping forces with precision. Ergonomics 51(2), 168–191.

2. Marcotte P, Adewusi S, Rakheja S, 2011. Development of a low-cost System to Evaluate Coupling Forces on

Real Power Tool Handles. Canadian Acoustics 39(2), 36–37.

3. Dewangan KN, Rakheja S, Marcotte P, Shahmir A, Patra SK, 2013. Comparisons of apparent mass responses of

human subjects seated on rigid and elastic seats under vertical vibration. Ergonomics 56, 1806–1822.

(a) (b) (c)

Ph

ase

Page 35: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

35

Session IV: Vibration Reduction and Exposure Control

Chairs: David Rempel and Uwe Kaulbars

Presenter Title and authors Page

Tammy Eger Evaluation of personal protective equipment as a control

strategy to reduce foot-transmitted vibration

Heather Byrnell, James P. Dickey, Alison Godwin and

Tammy Eger

36

Eckardt Johanning Tools of the trade– maintenance of way tools ergonomic

and vibration risk assessment

Eckardt Johanning, Paul Landsbergis, Rick Inclima

38

Marco Tarabini Reduction of the vibration transmitted to the hand by the

chisel of pneumatic chipping hammers

Diego Scaccabarozzi, Bortolino Saggin and Marco

Tarabini

40

Hans Lindell Hand-held impact machines with nonlinearly-tuned

vibration absorber

Hans Lindell, Viktor Berbyuk, Snævar Leó Grétarsson,

Mattias Josefsson

42

Ren G. Dong The effect of a mechanical arm tool support system on

workplace grinder vibrations

Thomas W. McDowell, Daniel E. Welcome, Christopher

Warren, Xueyan S. Xu, and Ren G. Dong

44

Page 36: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

36

EVALUATION OF PERSONAL PROTECTIVE EQUIPMENT AS A CONTROL

STRATEGY TO REDUCE FOOT-TRANSMITTED VIBRATION

Heather Byrnell+, James P. Dickey++, Alison Godwin+ and *Tammy Eger+

+Centre for Research in Occupational Health Safety, Laurentian University, Sudbury, ON, Canada

++School of Kinesiology, Western University, London, ON, Canada

Introduction

Occupational exposure to foot-transmitted vibration (FTV) occurs when a worker is

exposed to vibration that travels through the feet. In underground mining, exposure typically

occurs when standing on vibrating surfaces associated with the operation of locomotives, jumbo

drills, bolters, or raise platforms. Recent medical evidence confirms workers exposed to FTV can

develop cold induced blanching of the toes and permanent disruption of blood circulation and

innervation to the toes and feet leading to an occupational disease termed vibration induced white-

feet1. As part of a vibration management program some companies have started to use “anti-

vibration” mats and insoles in an effort to reduce harmful vibration levels. However, there are no

controlled studies that show the effectiveness of personal protective equipment (PPE) such as mats,

boots, or insole for vibration reduction. The primary objective of this study is to evaluate the

effectiveness of combinations of mat/workboot/insole for attenuation of FTV.

Methods

Three mats (M0=no mat; M1=mat 1; M2=mat 2), three boot (B1=boot 1; B2=boot 2; B3=

boot 3), and four insole conditions (I0=no insole; I1=insole 1; I2=insole 2: I3=insole3) were

randomly tested in combination at dominant FTV exposure frequencies associated with operating

a locomotive (3 Hz, Ax= 0.48, Ay=0.57, Az=0.84 m/s2), jumbo drill and bolter (30 Hz, Ax= 5.9,

Ay=7.18, Az=2.66 m/s2), and drilling off a raise platform (40 Hz, Ax= 2.0, Ay=3.22,

Az=5.59 m/s2)2. A vibration simulator (R-3000; Mikrolar, NH, USA) was used to generate the

vibration exposure profiles. The vibration attenuation of the mat/boot/insole combinations were

determined by comparing the vibration below the heel and toe to the platform vibration (ADXL326

ultra-miniature tri-axial accelerometers attached to the underside of the foot at the heel and first

metatarsal, and to the platform). A baseline transmissibility measurement, with each participant

standing on the platform (B0M0I0=no boot, no mat, no insole) was also recorded at the beginning

and end of each experimental session. Ten healthy males participated in the experiment with a

mean age, height and mass of 30 +/-9 yrs, 1.8 +/-0.7m 85 +/-10kg, respectively. Each PPE

combination was evaluated using a 10 second vibration exposure period.

Results and Discussion

Preliminary findings suggest that most of the PPE combinations were effective at

controlling FTV entering the first metatarsal and heel at 3 Hz, and the heel at 30 Hz

(transmissibilities were below 1); however the PPE was not effective for limiting FTV entering

the first metatarsal at 30 Hz (Figure 1) or 40 Hz (data not presented due to space limitations). The

increased transmissibility at the heel and first metatarsal at 30 Hz (compared to 3Hz) may be due

to the low mass and unconstrained nature of the toes, which results in greater acceleration at the

Page 37: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

37

toe than the heel. Furthermore the boots evaluated in this study all had a slight rocker that resulted

in the toe of the boot being raised above the platform surface. This shape may influence the weight

distribution between the baseline standing conditions and the PPE conditions. If the design of the

boot resulted in “un-weighting” at the first metatarsal then it could have contributed to the larger

transmissibility values recorded at the toe than the heel (Figure 1).

Future research will evaluate the best combination of PPE determined for 3 Hz, 30 Hz,

and 40 Hz in a field trial during operation of a locomotive, jumbo drill & bolter, and raise

platform respectively. If field trials are successful, the research team will partner with the mining

industry to disseminate information on the best combination of mat, boot, and insole products to

help reduce FTV exposures for mining workers.

References

1. Thompson, A., House, R., Krajnak, K., and Eger, T. (2010) Vibration-white foot: a case report. Occupational

Medicine 60: 572-574

2. Eger, T., Thompson, A., Leduc, M., Krajnak, K., Goggins, K., Godwin, A., and House, R. (2014) Vibration

induced white-feet: Overview and field study of vibration exposure and reported symptoms in workers. WORK:

A Journal of Prevention, Assessment & Rehabilitation 47(1): 101-110.

Figure 1: Measured FTV transmissibility from the platform through the PPE combinations to the underside of

heel (blue) and toe (red) at 3Hz dominant FTV exposure (top) and 30Hz FTV exposure (bottom) for 36

combinations of PPE and baseline (no PPE) at the beginning (B0M0I-Pre) and end of the trials (B0M0I0-post).

Note: The thick black line reflects a transmissibility value of 1 to help illustrate PPE combinations that resulted

in an attenuation of FTV (transmissibility values below 1).

Page 38: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

38

TOOLS OF THE TRADE– MAINTENANCE OF WAY TOOLS ERGONOMIC AND

VIBRATION RISK ASSESSMENT

*Eckardt Johanning+, Paul Landsbergis++, Rick Inclima+++

+Columbia University, New York, USA ++SUNY Downstate School of Public Health, Brooklyn, NY, USA

+++Brotherhood of Maintenance of Way Employees Division of the International

Brotherhood of Teamsters, Washington, DC, USA

Introduction

There is a paucity of information regarding the occupational health and ergonomic risk of hand

tools contributing to hand-arm vibration (HAV) exposure among maintenance-of-way workers (MoW) in

the rail industry. MoW workers are building and maintaining tracks, bridges, buildings and other rail

structures used by the railroads in the USA. Track construction and repair involves unique and specialized

tools, machinery and vehicles in order to move rail and ties, pull or drive spikes, distribute ballast in order

to line, and surface and gauge railroad track. We have previously reported about typical MoW vehicles and

whole-body vibration measurements in road- and off-road vehicles.1 Anecdotal reports suggest that

musculoskeletal disorders of the upper extremities are common health complaints among the more than

35,000 MoW employees. As part of a larger study in cooperation with the union of the MoW workers

(BMWED) a pilot study with a needs assessment and review of typical hand tools used in the industry was

performed. Much of the newer equipment used by MoW workers are powered by gasoline or diesel engines,

electricity, air or hydraulics, nevertheless the work tasks are typically very physical and demanding,

involving known ergonomic risk factors, vibration and climate challenges. 2,3 Prolonged and intense

occupational whole-body vibration (WBV) as well as HAV have long been recognized as important

mechanical stressors contributing to early and accelerated degenerative joint diseases, neck and back pain,

prolapsed discs or injuries to the hand. 4 5 The goal of this investigation is to develop a trade-specific

research priority list of tools that merit further investigation, including detailed HAV measurements

according to international guidelines.

Methods

A literature review was performed utilizing Medline and other online resources with the search

terms: vibration, HAV, maintenance of way, track worker, and railroad. In addition, data was collected

through expert interviews and explorations with senior MoW workers and union health and safety

specialists about the tools that may cause HAV exposure and its typical application and uses in the trade.

Based on this information a preliminary priority list was developed to focus field investigations and HAV

measurements according to international guidelines.

Results and Discussion

A Medline search for MoW tools and related health problems resulted in zero returns. Expert

interviews of workers and listings in trade publications described the following typical tools in the trade.

Hand tools without energized power source: Lining bar, anchor wrenches, ballast forks, claw bars, spike

maul (hammer), sledge hammer, track wrenches, rail fork (rail turner), tie tongs, rail tongs, and track jack. Hand tools with hydraulic, pneumatic , or gas/diesel powered: Tamping guns, spiking guns, rock and rail

drills, wrenches, grinders, impact tools, horizontal surface grinders, spike pullers and drivers, tampers and

rail saws, and gauging adzer.

Page 39: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

39

Table 1: Trade specific maintenance-of-way tools with known vibration exposure

No Tool Manufacturer Use Power

Hand use /

coupling

Vibration

data

available*

Exposure

risk

estimates*

1 Jack hammers Various Generic air bi-manual Yes Yes

2 Rock Drills Various Generic air bi-manual Yes Yes

3

Concrete

vibrator Various Generic air bi-manual Yes Yes

4 Hammer Drill Hilti Generic electric Dominant Yes Yes

5 Nail gun Hilti Generic electric Dominant Yes Yes

6

Reciprocating

saw Hilti Generic electric Dominant Yes Yes

7 Rivet buster Various MoW air Dominant unknown Unknown

8 Scabbler Various MoW air bi-manual unknown Unknown

9 Air hammer Various Generic electric Dominant Yes Yes

10 Impact wrench Various Generic air Dominant Yes Yes

11 Nut splitter Matweld MoW Bi-manual Yes Yes

12 Tamping gun Matweld MoW gas bi-manual Unknown Unknown

13 Profile grinder Various MoW gas bi-manual Unknown Unknown

14 Spike puller Matweld MoW Air bi-manual Unknown Unknown

15 Spiker guns Stanley MoW Hydraulic bi-manual Unknown Unknown

19 Spike driver Matweld Hydraulic bi-manual Unknown Unknown

16 Saws

Stanley

Geismar MoW

hydraulic

/ gas bi-manual Unknown Unknown

17 Impact tool Geismar MoW hydraulic bi-manual Unknown Unknown

18 Stone grinder Matweld MoW hydraulic bi-manual Unknown Unknown

19 Tamper Matweld MoW hydraulic Bi-manual Unknown Unknown

20 Rail drill Matweld MoW hydraulic bi-manual unknown Unknown * (http://www.portaleagentifisici.it/fo_hav_index.php?lg=EN) (https://las-bb.brandenburg.de/karla/recherche_outdoor.asp)

This pilot study showed that little to no information exists about possible ergonomic risks and HAV

exposure of hand tools that are typical and unique in the railroad Maintenance of Way trade. This

indicates a need for further research to aid in the prevention of musculoskeletal and HAV disorders

among track workers. We are seeking input from conference participants to refine this research protocol.

Literature

1. Johanning E. Vibration and shock exposure of maintenance-of-way vehicles in the railroad industry.

ApplErgon 2011;42:555-62.

2. Force JAT. Job Analysis Summary: Physical Demands and Environmental Conditions for the Job of

Section Laborer/Trackman. West Lafayette, Indiana1977 10 October 1977.

3. Barondess (Chair) JAeaP. Musculoskeletal Disorders and the Workplace. Low Back and Upper

Extremeties. Washington, D.C.: National Academy Press; 2001.

4. Bovenzi M. Health risks from occupational exposures to mechanical vibration. MedLav 2006;97:535-

41.

5. Pelmear PL, Leong D. Review of occupational standards and guidelines for hand-arm (segmental)

vibration syndrome (HAVS). Appl Occup Environ Hyg 2000;15:291-302.

Page 40: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

40

REDUCTION OF THE VIBRATION TRANSMITTED TO THE HAND BY THE

CHISEL OF PNEUMATIC CHIPPING HAMMERS

Diego Scaccabarozzi, Bortolino Saggin and *Marco Tarabini

Politecnico di Milano, Department of Mechanical Engineering

Via Previati 1/C, 23900 Lecco, Italy

Introduction

Hand-arm vibration syndrome is caused by prolonged exposure to hand-arm vibration

(HAV)1. Hand-held power tools and hand-guided mechanical equipment are primary causes of

HAV, as testified by wide scientific community attention aimed to reduce vibration

transmissibility between the hand and the source of vibration2-5. Suspensions are generally added

in the tool design phase or adapt to existing devices with specifically-designed elements. One

common assumption of these approaches is that the vibration source can be modelled as ideal

vibration generation whose velocity is measured during actual working condition, i.e. without

considering the effect of the hand-arm impedance. Moreover, a dominant axis is generally studied

without considering in the suspension design possible axes interaction. Finally, the operator

variability is not accounted in the design phase, and the impedances defined in ISO 10068 are

commonly used. A more accurate approach was proposed in ref. [6] where a model was developed

accounting for the real characteristics of the vibration source and for the operator variability. The

model validity was demonstrated by designing an optimized suspension for a pneumatic chipping

hammer that allowed reducing the vibration level of 50%; this allowed exploiting the full working

time of 8 h without exceeding the daily limit exposure.

In this work, the optimization method developed in ref. [6] has been used to investigate the

design feasibility of a suspension system for the chisel of chipping pneumatic hammers. The need

of a suspension is well understood if one considers that the operators, while performing craftwork,

directly guide the chisel with one hand. The vibration levels are reduced only by the usage of

gloves for hand protection and by a “loose grip” allowing for the axial motion of the chisel. The

request is therefore to conceive a system that firmly grasped by the operator allows him to

accurately drive the chisel without reducing the tool effectiveness and at the same time reducing

the hand transmitted vibration.

Method

The model shown in Figure 1, based on the mobility approach, is the reference scheme for

the optimization process. The vibration source is modelled as ideal vibration generator with its

impedance Mg, represented mostly by the tool mass. The vibration velocity vg can be obtained

measuring the velocity at the hand-arm interface vh and the hand-arm operator impedance Mh.

The suspension system connects the generator to the hand-arm through impedances that are

represented by three terms, i.e. suspension mass Ms, stiffness Mk and damping Mc. Being the

generator characteristics known or measured, the velocity at the hand-arm interface can be

minimized with an optimal design of the suspension parameters. Thus, the suspension design is a

non-linear constrained optimization problem that can account for some specific technological

limitations and functional constraints for each studied case. In this work, design constraints are

summarized by the total suspension mass of 0.6 kg, by the radial static deflection of 10 mm under

a 40 N holding force and free sliding along the axial direction.

Page 41: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

41

Results and Discussion

Experimental activity has been performed to measure the vibration levels on the chisel (Table 1).

Equivalent acceleration levels have been computed according to ISO 5349. Results evidenced an

equivalent vibration level ahw (about 13 m/s2)

well above the limit of 5 m/s2, therefore

confirming the need of a suspension system for

the operator hand. Two solutions have been

envisaged. In the first case, the chisel

suspension is axially linked to the hammer body

and the chisel can axially slide. The axial

suspension, in this case, has no stiffness but

only friction and the actual suspension is only

radial. In the second configuration, that is more

similar to the current handling mode (and so

preferred by the operators) the chisel suspension

is mounted on the chisel itself and an axial

stiffness is needed to keep its place. The two

optimal solutions share the radial parameters

while for the first the axial parameters are

nominally zero. Table 1 Measured vibration levels on the chisel

Table 2 shows the optimal scenario for the second

configuration. The adoption of the computed parameters

allows achieving an RMS acceleration level that is about

the half of the original value, with considerable

extension of the working time up to about 8 h per day.

Table 2 Suspension parameters deriving from the optimization

Mass [kg] Axial stiffness

[N/mm]

Radial stiffness

[N/mm]

Axial damping

coefficient

Radial damping

coefficient

ahw

[m/s2]

0.6 4 2 0.3 0.2 5.74

References

1. M.J. Griffin, Handbook of Human Vibration, Academic Press, 1996.

2. E.M. De Souza, T.N. Moore, Field performance evaluation of a rock drill handle design, Mining Engineering 45

(1993) 1402–1405.

3. K. Prajapati, P. Hes, Reduction of hand–arm transmitted vibration on pneumatic jackleg rock drills, CIM

Bulletin 94 (2001) 56–59.

4. R. Oddo, T. Loyau, P.E. Boileau, Y. Champoux, Design of a suspended handle to attenuate rock drill hand–arm

vibration: model development and validation, Journal of Sound and Vibration 275 (2004) 623–640.

5. B. Sam, K. Kathirvel, Development and evaluation of vibration isolators for reducing hand transmitted vibration

of walking and riding type power tillers, Biosystems Engineering 103 (2009) 427–437.

6. B. Saggin, D. Scaccabarozzi, M. Tarabini, Optimized design of suspension systems for hand–arm transmitted

vibration reduction, Journal of Sound and Vibration 331, (2012) 2671–2684.

Direction according to

ISO 10068

RMS acceleration

[m/s2]

yh 4.88

xh 6.81

zh 10.04

equivalent vibration generator

Mg

vg

suspension

operator

Mh

Mk

Mm

Mc

vh

Ms

vs

Figure 1 Proposed model for optimal suspension design

Page 42: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

42

HAND-HELD IMPACT MACHINES WITH NONLINEARLY-TUNED VIBRATION

ABSORBER

*Hans Lindell, Viktor Berbyuk, Snævar Leó Grétarsson, Mattias Josefsson

*Swerea IVF, Box 104, 431 22, Mölndal, Sweden

Chalmers University of Technology, 412 96, Göteborg, Sweden

E-mails: [email protected], [email protected], [email protected], [email protected]

Introduction

Vibration exposure from hand-held impact machines (HHIM) such as rock drills, rammers and breakers with

a reciprocating action is a major cause for injuries to the workers in the industry. In order to improve the work

environment in the stone industry, a project was started with the objectives to redesign the tools to achieve low

vibration as well as improved ergonomics, dust removal and reduced noise while maintaining productivity1. Redesign

of current hand-held pneumatic impact machines can reduce the vibration level and thereby reduce injuries to workers.

Hand-arm vibration injury, often called Hand Arm Vibration Syndrome (HAVS) is one of the most common reasons

for work related injuries among this group of workers in the industry.

Although pneumatic impact machines have been used since the early 20th century little has been changed in

their fundamental design to date. Despite their being robust and efficient, vibration, noise, dust and poor ergonomics

cause a large number of injuries to the operators. Previous work has been done to reduce vibrations from these

machines of which some have been patented2,3. One approach is to use traditional linear tuned vibration absorbers

(TVA) invented in 1909 by Frahm and described by Den Hartog4. Although this technology is to a large extent limited

in practical use on this application due to it is only effective in a narrow frequency range. At higher frequencies the

TVA will instead increase the vibration and at lower frequencies will the effect rapidly decrease.

However, by introducing nonlinear spring characteristic of the absorber mass the effective frequency range

can be greatly increased and thereby can the technology be effectively implemented to this kind of machines5. As a

result a new generation of impact machines is developed by approaching the redesign from a user perspective, and

starting adhering to strict conditions of low vibration, noise and dust as well as sound ergonomics. The objective of

this study has therefore been to develop a user friendly low vibration impact machine using nonlinear tuned vibration

absorber together with integrated vibration isolation. A HHIM with a nonlinear tuned vibration absorber combined

with vibration isolation has shown to significantly reduce the vibration on the operator from 20 m/s2haw to a level close

to 2.5 m/s2haw.

Methods

The machine consists of a piston moving inside a cylinder hitting the working tool driven by compressed air.

The cylinder is in turn attached to a housing via vibration isolators. The operator handles are attached to the top of the

housing. An engineering model (E-model) of the HHIM in question is shown in Figure 1. The Nonlinear Tuned

Vibration Absorber (NTVA) comprises a mass which is moving along the machine restricted by a nonlinear stiffness.

The nonlinearity is in the simplest execution realized by introducing a gap between two springs and prestress in the

springs. From the E-model a mathematical model (M-model) is developed by setting up the equations of motion which

in turn is transformed to a computational model (C-model) realized in MATLAB code.

The vibration reduction of the HHIM was accomplished by using two combined approaches: 1) a NTVA was

designed that creates a counter force to the reaction forces on the cylinder of the piston and is effective in a broad

frequency range, and 2) vibration isolation between the impact mechanisms and the housing that the handles are

attached to. The isolation is applied in the axial, radial and rotational direction in order to further reduce the vibrations

that still remain from the piston and those from the chisel hitting the stone. Care has been taken not to compromise

the ability to accurately control the machine.

Results and Discussions

The C-model of the machine in question was verified both in a test rig and on a HHIM prototype and shows

sufficient correlation. The C-model has been used to simulate the machine vibration dynamics for different operational

scenarios. Sensitivity analysis of the vibration dynamics has been done with respect to system structural parameters.

It was found that vibration dynamics is strongly sensitive to variation of the values of gap, stiffness and spring’s

Page 43: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

43

prestress of the NTVA, and is subject to optimization. The optimization problem has been stated and solved

numerically. Figure 2 shows the vibration reduction effect for different scenarios. Line A is the vibration from a

traditional machine with m, M and MH fixed. Line B is from a machine with vibration isolation between M and MH.

Line C is a traditional TVA and finally Line D is the vibration from an optimized NTVA. Due to variations in machine

load, spread in production etc which leads to variations in operating frequency is the expected operating range between

23 and 33 Hz.

What can be found is that the average vibration reduction from the original machine in the operating range

is estimated to be 95% for the NTVA plus vibration isolation (Line D), 50% for only vibration isolation (Line B).

Finally the linear TVA plus vibration isolation is about 60% which is just slightly more than with only the vibration

isolation but with very high frequency dependence.

Figure 2 E-model of HHIM with NTVA Figure 2 Vibration at machine handle from C-model

The project has built several prototype machines which have been field tested with good results and a small

scale production is planned. In addition to the low vibration also other improvements have been measured and

observed: feed force from the operator is more than halved, weight of the machine is halved, sound power is reduced

by >10 dBA, increased efficiency, longer tool life, improved dust extraction and finally greatly improved ergonomics

with adjustable handle length. The conclusion is that the concept with NTVA and potentially with a vibration isolation

can greatly reduce vibration exposure from machines with reciprocating vibrations in a very cost efficient manner.

References

1. Lindell H. (2011) Redesign of hand-held impact machines to reduce hand-arm vibration, Twelfth International

Conference on Hand-Arm Vibration, Ottawa, Canada, June 13 – 17, 80 – 81.

2. Moessnang F. US Patent US7712548B2

3. Henriksson S. Ostensson O. US Patent US20080073095A1

4. Den Hartog, J. P. (1985) Mechanical Vibrations, New York, Dower Publication, Inc

5. Lindell H. Patent WO 2014/095936 A1

Acknowledgements: This project was funded by AFA Insurance, AP Sten, Benders and Emmaboda Granit. A

special thanks to Bert Andersson, TM Verkstad for manufacturing prototypes.

0

0,2

0,4

0,6

0,8

1

1,2

1,4

1,6

10 15 20 25 30 35 40

Dis

pla

cem

en

t [m

m r

ms]

Piston frequency [Hz]

Vibration at handle

A: No vib. isol. B: Fixed counter mass C: Linear TVA D: Nonlinear TVA

Expected operating range

m

c1

c2

k1

k2

a

az(t)

zM(t)

mp

kh/2ch/2 kh/2

ch/2

z

Fc(t)

P

M

kHcH

MH

zH(t)

kMcM

Page 44: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

44

THE EFFECT OF A MECHANICAL ARM TOOL SUPPORT SYSTEM ON

WORKPLACE GRINDER VIBRATIONS

Thomas W. McDowell, Daniel E. Welcome, Christopher Warren,

Xueyan S. Xu, *Ren G. Dong

Engineering and Control Technology Branch, Health Effects Laboratory Division,

National Institute for Occupational Safety & Health, Morgantown, WV, USA

Introduction

Repetitive powered hand tool operations requiring high forces have been associated with

workplace musculoskeletal disorders, especially in the lower back and upper limbs.(1, 2) In efforts

to alleviate some of the stressors associated with such tool operations, and to increase productivity,

the US Department of Defense has been evaluating the use of counter-balanced mechanical arms

to support tools such as sanders, grinders, and large drills during overhead and other stressful

operations at large US Navy shipyards and US Air Force aircraft maintenance facilities. However,

the use of this intervention can significantly increase the daily time on task, which in turn increases

the time that tool operators are exposed to other potentially harmful agents such as respirable dust,

noise, and hand-transmitted vibration (HTV). The effect of the mechanical arms on tool vibration

emissions is unknown. To begin to address this knowledge gap, the purpose of this study was to

assess tool handle vibrations of pneumatic grinders as they were operated during typical shipyard

grinding tasks with and without the support of a mechanical arm system.

Methods

Four new pneumatic grinders were used in the evaluations (Table 1). Each grinder/wheel

combination weighed about 6 kg. The mechanical arm used to support the grinders was an

Equipois® zeroG4 arm mounted on a mobile Equipois UMS Quad Stand (see Fig. 1). This arm is

designed to support loads up to about 19 kg. At a large US Navy shipyard, four grinder operators

used the tools to complete surface grinding tasks on mild steel. One workstation involved vertical

grinding with the steel surface at about shoulder height, while the second work task involved

horizontal grinding (pictured in Fig. 1).

Frequency-weighted and unweighted tri-axial

acceleration data were collected at both tool handles

in accordance with ISO 5349-1 (2001)(3) as each

operator completed five consecutive 10-second data

collection trials with each tool/support

condition/workstation combination (5×4×2×2 = 80

trials per operator). Grinding wheels were discarded

and replaced with brand new ones after each 5-trial

data collection period.

Tool Make Model Wheel Type

A Ingersoll-Rand 88V60S106 6" flared cup

B Atlas Copco GTG40 S060-927 9" disk

C Ingersoll-Rand 99V60P109 9" disk

D Honsa HTVG 36 6" flared cup

Fig. 1. Tool handle vibrations are recorded as an

operator performs the horizontal grinding task

with Tool B supported by the mechanical arm.

The left handle was used as the arm system

attachment point for each tool.

Table 1. Descriptions of the grinders used in the

evaluations along with the grinding wheel types.

Page 45: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

45

Results and Conclusions

The average measured acceleration was

slightly higher at the left tool handle than the right

handle for all four grinders. Acceleration averages

for the vertical and horizontal grinding tasks were

not statistically different.

Each grinder’s average one-third octave band

frequency spectra measured at the left tool handle

while the operators performed the horizontal

grinding task are shown in Fig. 2. Frequency-

weighted and unweighted acceleration averages for

both grinding tasks under both support conditions

are presented in Table 2. As indicated in the figure

and table, the use of the Equipois mechanical arm

support did not substantially affect the grinder

handle vibrations. In most cases, the average

acceleration was reduced somewhat with the use of

the mechanical arm system, but in general, the

vibration was not effectively attenuated by this

intervention. These results indicate that while the

use of the mechanical arm can reduce some of the stressors associated with the operations of heavy

powered hand tools, the increased time on task afforded by the system would likely increase daily

time-weighted HTV exposures. This apparent trade-off needs further examination.

References 1. NIOSH. Musculoskeletal Disorders and Workplace Factors: A Critical Review of Epidemiologic Evidence for

Work-Related Musculoskeletal Disorders of the Neck, Upper Extremity, and Low Back, NIOSH Publication 97-

141. Cincinnati, OH: U.S. Department of Health and Human Services, National Institute for Occupational Safety

and Health; 1997.

2. Chourasia AO, Sesto ME, Block WF, Radwin RG. Prolonged mechanical and physiological changes in the upper

extremity following short-term simulated power hand tool use. Ergonomics. 2009;52(1):15-24.

3. ISO 5349-1: Mechanical Vibration -- Measurement and Evaluation of Human Exposure to Hand-Transmitted

Vibration -- Part 1: General Requirements. Geneva: International Organization for Standardization, 2001.

0.10

1.00

10.00

100.00

1 10 100 1000 10000

Un

we

igh

ted

Acc

ele

rati

on

(m

/s2)

Frequency (Hz)

A

B

C

D

Tool

Condition: UnsupportedTask: Horizontal grinding

0.10

1.00

10.00

100.00

1 10 100 1000 10000

Un

we

igh

ted

Acc

ele

rati

on

(m

/s2)

Frequency (Hz)

A

B

C

D

Tool

Condition: SupportedTask: Horizontal grinding

Fig. 2. The average one-third octave-band frequency spectra for each of the four tools used in the

horizontal grinding task in the (a) unsupported condition and (b) the supported condition.

Table 2. The unweighted and frequency-

weighted acceleration averages for the left

handle of each grinder in both support

conditions for each workstation.

(a) (b)

Workstation 1 (vertical grinding)

Unweighted Weighted Unweighted Weighted

Tool (m/s2) (m/s

2) (m/s

2) (m/s

2)

A 130.9 5.1 122.3 4.5

B 134.9 5.6 190.0 5.7

C 106.9 3.0 87.1 3.2

D 91.1 8.0 61.5 4.7

Workstation 2 (horizontal grinding)

Unweighted Weighted Unweighted Weighted

Tool (m/s2) (m/s

2) (m/s

2) (m/s

2)

A 153.6 6.6 91.7 4.6

B 148.7 6.5 142.5 4.6

C 111.8 2.6 108.7 2.8

D 92.8 8.2 59.3 4.4

Unsupported Supported

Unsupported Supported

Page 46: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

46

Poster Session

Chairs: Qingsong Chen and Ren G. Dong

Presenter Title and authors Page

Qingsong Chen A preliminary investigation on the factors influencing the

vibration of a handheld workpiece during its fine

polishing process

Hansheng Lin, Guiping Chen, Shichuan Tang, Bin Xiao,

Guoyong Xu, Maosheng Yan, Hua Yan, Qingsong Chen

47

Qingsong Chen Plasma biomarkers of peripheral vascular damage in

workers exposed to hand-transmitted vibration - a case-

control study

Qingsong Chen, Fansong Zeng, Li Lang, Shichuan Tang,

Bin Xiao, Aichu Yang, Hansheng Lin, Hanlin Huang

49

Qingsong Chen Serum proteomic analysis among workers with hand-arm

vibration syndrome

Maosheng Yan, Danying Zhang, Fansong Zeng, Bin

Xiao, Li Lang, Hongling Li, Guiping Chen, Qingsong

Chen

51

Page 47: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

47

A PRELIMINARY INVESTION ON THE FACTORS INFLUENCING THE VIBRATION

OF A HANDHELD WORKPIECE DURING ITS FINE POLISHING PROCESS

Hansheng Lin+, Guiping Chen+, Shichuan Tang++, Bin Xiao+, Guoyong Xu+,

Maosheng Yan+, Hua Yan+, *Qingsong Chen+ +Guangdong Province Hospital for Occupational Disease Prevention and Treatment, Guangdong

Provincial Key Laboratory of Occupational Disease Prevention and Treatment, Guangzhou,

Guangdong 510300, China; ++Key Laboratory of Occupational Health and Safety, Beijing Municipal Institute of Labor

Protection, Beijing, China Correspondence author: [email protected]

Introduction

Fine grinding or polishing of handheld workpieces can be found in labor-intensive hardware

manufacturers for making sport equipment, tools, etc. The grinding or polishing processes are characterized

by prolonged and intensive exposure to fingers-transmitted or hand-transmitted vibration. Such vibration

exposure has resulted in a significant prevalence (> 15%) of vibration-induced disorders among workers

performing the grinding and polishing tasks1. Preliminary observations suggest that the rotational speed of

the grinding or polishing machine, its seat cushion, and the type of grinding or polishing wheel are among

the major factors that influence the vibration exposure of the workers during the operations. However, their

exact effects have not been sufficiently identified and understood. This study aimed to further verify and

understand these influencing factors by examining a typical polishing operation and to explore methods for

improving the operation conditions in order to reduce the vibration exposure among the workers.

Method

A fine polishing process of golf club head was simulated in this study, which is shown in Figure 1.

A single-head polishing machine was used in the simulation. To avoid the effect of any human subject on

the vibration of the golf club head, a pneumatic device was specially designed, built, and used to push the

golf club head to the polishing wheel with a constant push force (9.8 N) to simulate the polishing process.

An acceleration measuring probe of a portable human vibration analyzer (SV106) was inserted into the golf

club head. The head was then attached to the pneumatic pushing device and pushed against the polishing

wheel in the experiment. To examine the effect of the rotation speed of the polishing machine on the

workpiece vibration, three rotation speeds (1200 r/min, 1800 r/min, 2400 r/min) were tested on the original

setup of the polishing machine used in the gold equipment manufacturer. To examine the effect of the seat

cushion of the polishing machine on the vibration, two types of seat cushions (ordinary plastic mat and

high-elastic rubber mat, Figure 2) were installed at the bottom of the grinding machine and used in the test

under the same grinder speed (2400 r/min). Two types of polishing wheels (certified polishing wheel,

uncertified polishing wheel, Figure 3) were also tested under the same speed (2400 r/min) to examine the

effect of the polishing wheel. The vibration analyzer directly measures the frequency-weighted acceleration

defined in ISO 5349-1 (2001)2. An ANOVA was performed to determine the significance of the effects.

Independent sample t-tests were also performed to examine the significance of the vibration differences.

Results and Discussions

For the ordinary plastic mats at the three speed levels (1200 r/min, 1800 r/min, and 2400 r/min), the

weighted accelerations ( X S ) were 0.86±0.04 m/s2, 1.12 ±0.04 m/s2, and 1.84 ± 0.05 m/s2, respectively,

and they were significantly different (p <0.05). The data indicates that increasing the rotational speed

substantially increased the weighted acceleration. This is likely because the polishing wheel is not fully

balanced and the inertial vibrating force of the unbalanced mass theoretically increases approximately with

the square of the rotation speed. At 2400 r/min, the acceleration with the high elastic rubber (1.35±0.05

m/s2) was significantly lower than that with the ordinary plastic mats (1.84±0.05m/s2; p <0.05). This

suggests that the suspension of the polishing machine is likely to play a certain role in the vibration response

of the system. With the ordinary plastic mats at 2400 r/min, the vibration acceleration with an uncertified

Page 48: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

48

polishing wheel (2.37±0.07 m/s2) was significantly higher than that of certified polishing wheel (1.84±0.05

m/s2; p<0.05). This suggests that it is better to avoid using the uncertified polishing wheel in the operation.

These findings indicate that the vibration exposure of the workers in such a polishing process can be reduced

by improving the design and maintenance of the polishing machine and the use of a better polishing wheel.

References

1. Qingsong Chen, Bin Xiao, Aichu Yang, Hansheng Lin, Hua Yan, Li Lang, Maosheng Yan, Guiping

Chen, Fansong Zeng, Xuqing Cao. The characteristics of vibration-induced white finger in workers

polishing handheld pieces in the southern subtropics of china. Proceedings of the 13th International

Conference on Hand-Arm Vibration, Beijing, China, October 2015.

2. International Organization for Standardization (2001) ISO5349-1. Mechanical vibration and shock —

Measurement and evaluation of human exposure to hand-transmitted vibration —Part 1: General

requirements.

Figure 2: Ordinary plastic mat (left) and high elastic

rubber mat (right)

Figure 3: Certified polishing wheel (left) and

uncertified polishing wheel (right)

Page 49: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

49

PLASMA BIOMARKERS OF PERIPHERAL VASCULAR DAMAGE IN WORKERS

EXPOSED TO HAND-TRANSMITTED VIBRATION - A CASE-CONTROL STUDY

*Qingsong Chen+, Fansong Zeng+, Li Lang+, Shichuan Tang++, Bin Xiao+,

Aichu Yang+, Hansheng Lin+, Hanlin Huang+

+Guangdong Province Hospital for Occupational Disease Prevention and Treatment

Guangdong Provincial Key Laboratory of Occupational Disease Prevention and Treatment,

Guangzhou, Guangdong 510300, China ++Key Laboratory of Occupational Health and Safety, Beijing Municipal Institute of Labor

Protection, Beijing, China

Correspondence to: [email protected]

Introduction

A lack of sensitive, specific, and objective indicators exist for diagnosing and staging peripheral

vascular damage related to hand-arm vibration syndrome (HAVS). Results of previous studies

demonstrated that serotonin (5-HT), endothelin-1 (ET-1), soluble intercellular adhesion

molecule-1 (sICAM-1), and transforming growth factor beta 1 (TGF-β1) played significant roles

in the pathogenesis of vascular disease. The current study investigates whether these factors

could be applied in the diagnosis of peripheral vascular damage due to HAVS.

Methods

In our study, 43 male workers with vibration-induced white finger (VWF) and 44male workers

without VWF who were exposed to hand-transmitted vibration from thesame metal work factory

were selected as cases and controls, respectively. Plasma 5-HT, ET-1, TGF-β1, and sICAM-1 levels

were determined by enzyme-linked immunosorbent assay in these groups. Differences were also

assessed according to whether workers were exposed to high vs low vibration.

Results and Discussions

5-HT, ET-1, and TGF-β1 levels between VWF and No-VWF groups were significantly different

(p<0.05, p<0.001, and p<0.01, respectively), even after accounting forage, and smoking and

drinking statuses (p<0.05, p<0.001, and p<0.05, respectively). According to ROC analysis and

diagnostic tests, plasma ET-1 and TGF-β1were determined to be apposite parameters for predicting

VWF and vascular injury (cut-off value: 47.55 pg/mL, AUC: 0.760 [0.649–0.871], p<0.001; cut-

off value: 1.75 ng/mL AUC: 0.691 [0.573–0.808], p<0.01, respectively). In contrast with workers

exposed to low vibration, the average plasma 5-HT, ET-1, sICAM-1, and TGF-β1 levels were

elevated in those exposed to high vibration. These differences were statistically significant

(p<0.05), with the exception of sICAM-1. So, Plasma ET-1 and TGF-β1 seem to be sufficient

indicators in the diagnosis of peripheral vessel damage due to HAVS.

Page 50: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

50

Figure 1: ROC analysis of variables

References

1. Grześk G, Szadujkis-Szadurska K, Matusiak G, Malinowski B, Gajdus M, Wiciński M,

Szadujkis-Szadurski L. Influence of celecoxib on the vasodilating properties of human

mesenteric arteries constricted with endothelin-1. Biomed Rep, 2014. 2(3): 412-418.

2. Yammine L, Kang DH, Baun MM, Meininger JC. Endothelin-1 and psychosocial risk factors

for cardiovascular disease: a systematic review. Psychosomatic medicine, 2014. 76(2):109-

121.

3. Lev PR, Salim JP, Marta RF, Osorio MJ, Goette NP, Molinas FC. Platelets possess functional

TGF-beta receptors and Smad2 protein. Platelets, 2007. 18(1): p. 35-42.

4. Liu Y, Tian H, Yan X, Fan F, Wang W, Han J. Serotonin inhibits apoptosis of pulmonary artery

smooth muscle cells through 5-HT2A receptors involved in the pulmonary artery remodeling

of pulmonary artery hypertension. Exp Lung Res, 2013. 39(2): 70-79.

5. Kennedy G, Khan F, McLaren M, Belch JJ. Endothelial activation and response in patients

with hand arm vibration syndrome. Eur J Clin Invest, 1999. 29(7): 577-581.

Page 51: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

51

SERUM PROTEOMIC ANALYSIS IN WORKERS WITH

HAND-ARM VIBRATION SYNDROME

Maosheng Yan, Danying Zhang, Fansong Zeng,

Bin Xiao, Li Lang, Hongling Li, Guiping Chen, *Qingsong Chen

Guangdong Province Hospital for Occupational Disease Prevention and Treatment;

Guangdong Provincial Key Laboratory of Occupational Disease Prevention and Treatment,

Guangzhou, Guangdong 510300, China *Correspondence to: [email protected]

Introduction

Hand-Arm Vibration Syndrome (HAVS), a secondary form of Raynaud’s disease, is induced

by hand-transmitted vibration amongst industrial workers1. To date, the pathogenesis of this

disease is still not completely understood; however, dysregulation of autonomic and intravascular

alterations (such as platelet activation, oxidative stress, and leukocyte hyper-activation) have been

observed2.It was previously demonstrated that the serum levels of several proteins were

significantly different in patients with HAVS3. The aim of this work was to evaluate protein

expression changes in the serum of HAVS patients.

Methods

We used quantitative iTRAQ LC-MS/MS analysis to identify proteins that were differentially

expressed in the serum of a non-vibration-exposed control group (NVEC), a vibration-exposed

group(VEC), and a HAVS patient group (HAVS). The latter group was subdivided into two disease

severity groups (mild and severe). Eight serum samples were pooled for determination in every

group. A multivariate logistic regression analysis was used to identify predictive biomarkers.

Results

In total, compared with the NVEC group, 74 differentially expressed proteins were identified

in the VEC and HAVS groups (Fig1 a). Of these, 40 proteins were under expressed and 34 were

over expressed in the VEC and HAVS groups. Compared with the VEC group, 80 differentially

expressed proteins were identified in the HAVS group (Fig1 b). In addition, 80 differentially

expressed proteins were identified between the VEC and HAVS groups (Fig1 b). Of these, 55

proteins were under expressed and 25 were over expressed in the HAVS group. A bioinformatics

analysis of the differentially expressed proteins demonstrated that they participated in various

biological processes, and focal adhesion pathways was one of the major Kyoto Encyclopedia of

Genes and Genomes (KEGG) pathways(Fig 2).

Discussion

Taken together, using a proteomic approach, our findings suggest that, compared with those

not exposed, differential protein expression occurs in the serum of workers exposed to vibrations.

The expression of numerous proteins varies by disease severity and these differentially expressed

proteins are potential serum biomarkers for HAVS. Finally, focal adhesion was one of the major

pathways identified in the pathogenesis of the HAVS4.

Page 52: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

52

References

1. Bovenzi M. Exposure-response relationship in the hand-arm vibration syndrome: an overview of current

epidemiology research. Int Arch Occup Environ Health. 1998, 71(8):509-519.

2. Herrick AL. Pathogenesis of Raynaud's phenomenon. Rheumatology (Oxford). 2005, 44(5):587-596.

3. Kohout J, Topolcan O, Bejckova H. The serum level of endothelin in patients with hand-arm vibration

syndrome. Cent Eur J Public Health. 1995, 3 Suppl:43-44.

4. Ho YY, Lagares D, Tager AM, Kapoor M. Fibrosis--a lethal component of systemic sclerosis. Nat Rev

Rheumatol. 2014, 10(7):390-402.

Fig 1. Protein ratio distribution. (A) Healthy control groups vs exposed and HAVS patient groups; (B)

Exposed groups vs HAVS patient groups.

Fig 2. Bioinformatic analysis of differentially expressed proteins demonstrating that focal

adhesion was one of the major pathways involved.

A B under expressed

over expressed

under expressed

over expressed

Page 53: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

53

Session V: Characterization of Biodynamic Responses

Chair: Sven Matthiesen and John Z. Wu

Presenter Title and authors Page

Xueyan S. Xu A preliminary investigation on the vibration

transmissibility at the shoulder and neck

Xueyan S. Xu, Daniel E. Welcome, Christopher Warren,

Thomas W. McDowell, John Z. Wu, Ren G. Dong

54

Xueyan S. Xu Mechanical shock transmission through the hand-arm

system to the shoulder, back, head and neck

Daniel E. Welcome, Xueyan S. Xu, Christopher Warren,

Thomas W. McDowell, John Z. Wu, Ren G. Dong

56

Christophe Noël Development and use of an experimental device

including a laser scanning vibrometer for measuring the

vibration transmissibility mapping on the dorsum of

hands gripping a vibrating handle

Christophe Noël

58

Enrico Marchetti Hand-arm vibration transmissibility measurement for

assessing hearing impairment

Enrico Marchetti, Renata Sisto, Alessandro Lunghi,

Floriana Sacco, Filippo Sanjust, Raoul Di Giovanni,

Teresa Botti, Angelo Tirabasso

60

Almaky Almagirby A new methodology for measuring vibration

transmissibility on a gripped handle for HAVS research

Almaky Almagirby, Matt J. Carré, Jem A. Rongong

62

Marco Tarabini Nonlinearities in the biodynamic response of the hand-

arm system to single-axis vibration

Marco Tarabini, Lan Xie, Bortolino Saggin, Diego

Scaccabarozzi

64

Page 54: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

54

A PRELIMIRAY INVESTIGATION ON THE VIBRATION TRANSMISSIBILITY

AT THE SHOULDER AND NECK

*Xueyan S. Xu, Daniel E. Welcome, Christopher Warren,

Thomas W. McDowell, John Z. Wu, Ren G. Dong

Engineering and Control Technology Branch, Health Effects Laboratory Division,

National Institute for Occupational Safety & Health, Morgantown, WV, USA

Introduction

Although the association between vibration exposure and musculoskeletal disorders (MSDs)

in the shoulder and neck was reported in some studies1,2, it remains unclear whether and how the

vibration exposure can directly or indirectly affect the development of the shoulder and neck

MSDs. To have a direct influence, substantial vibration would have to be transmitted to the

shoulder and neck. This may happen in the operations of some low-frequency (<25 Hz) tools such

as vibrating forks, sand rammers, and road breakers. However, it remains unclear exactly how

much vibration can be effectively transmitted to the shoulder and neck from the handle-hand

interface. As the first step to enhance the understanding of the vibration effects on the shoulder

and neck MSDs, this study investigated the vibration transmissibility on the shoulder and neck.

Methods

Eight adult subjects participated in the study. As shown in Fig. 1, the experiment was carried

out on a 1-D vibration test system. Each subject used both hands to grip and push on the handles

fixed on the test system. A broadband random vibration from 4 to 100 Hz was used as the

excitation. The vibration transmissibility frequency spectra were measured on the skin at five

locations distributed on the upper arm, shoulder, and neck using a scanning laser vibrometer

(Polytec, 3-D scanning laser). The independent variables include total push force (50 N, 75 N, 100

N) and elbow bending angle (90º, 120º). Apparent mass at the palm of the hand was also measured.

Fig. 1. A pictorial view of the subject test and measurement locations

Results and Discussions

Example results for one specific push/grip force and arm posture are shown in Fig. 2, which

displays the vibration transmissibility spectra of 8 subjects at the 5 locations, as well as apparent

1

2 3 4

5

1

2 3

4

5 Laser 1-D shaker

Symmetric

handles

Page 55: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

55

mass. As expected, the vibration transmissibility decreased with the increased distance from the

vibrating source. Not much vibration was transmitted to the neck and back, with the maximum

transmissibility of less than 0.3 (P1 to P3). Vibration transmitted to the back surface of the shoulder

(P4) was slightly higher, with a peak of less than 0.5, except that measured with one of the subjects.

The highest transmissibility was observed in the spectra measured on the upper arm (P5), with a

mean peak magnitude of 1.33 at 8 Hz. The peak frequency in the apparent mass spectrum was

generally correlated with that of the vibration transmissibility measured on the upper arm. The

peak frequency of the mean apparent mass function was also 8 Hz. Subject differences are

obviously shown in both transmissibility and apparent mass.

Low-frequency tools can generate significant vibrations usually in the range of 5 to 25 Hz.

The results of this study indicate that such vibrations can be effectively transmitted to and amplifed

on the upper arm. A lesser portion of the vibration can be transmitted to the shoulder and neck.

The correlation between the transmissibility and apparent mass is consistent with their theoretical

relationship3.

Frequency (Hz)

Fig. 2. Averaged vibration transmissibility spectra and apparent mass of each subject

References

1. Van der Windt D.A., Thomas E., Pope D.P., et al. Occupational risk factors for shoulder pain: a systematic review.

Occupational and Environmental Medicine, 57 (7) (2000), pp. 433–442

2. Ariens G.A., Van Mechelen W., Bongers P.M., et al. Physical risk factors for neck pain. Scandinavian Journal of

Work, Environment and Health, 26 (1) (2000): 7–19.

3. Dong RG, Welcome DE, McDowell TW, Wu JZ. Theoretical relationship between vibration transmissibility and

driving-point response functions of the human body. Journal of Sound and Vibration. 332 (2013): 6193-202.

Apparent Mass

P5 P4

Tra

nsm

issi

bil

ity

in

vib

rati

on

dir

ecti

on

P1 P2 P3

Page 56: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

56

MECHANICAL SHOCK TRANSMISSION THROUGH

THE HAND-ARM SYSTEM TO THE SHOULDER, BACK, HEAD AND NECK

Daniel E. Welcome, *Xueyan S. Xu, Christopher Warren,

Thomas W. McDowell, John Z. Wu, Ren G. Dong

Engineering and Control Technology Branch, Health Effects Laboratory Division,

National Institute for Occupational Safety & Health, Morgantown, WV, USA

Introduction

Impulsive tools such as road breakers, stone hammers, and chipping hammers are used at

some workplaces. The mechanical shocks generated on such tools may be transmitted to hands,

arms, shoulders, back, neck, and head of the tool operators. Prolonged exposure to the shocks,

combined with a forceful exertion during the tool operation, may cause injuries and disorders in

these substructures of the human body. While considerable work has been done to characterize the

response of the hand-arm system to random broadband vibration, limited investigation has been

done on the transmission of the shocks in the upper extremities of the human body1. To help

understand the shock-induced injuries and disorders, the objective of this study is to investigate

the propagation of the mechanical shocks in the upper extremities.

Methods

The study was conducted on a 1-D hand-arm vibration test system, as shown in Figure 1. Eight

adult subjects - six males and two females - participated in the experiment. Each subject used both

hands to grip (10N each hand) and push (75N total) on dual instrumented handles fixed on the test

system; the push force was also measured with a force plate. The subjects pushed with an elbow

posture of 120º as shown in the Figure. Half sine mechanical shocks with a duration of 15ms and

magnitude of 5g were used for the exposure. The shock responses in time history were measured

on retro-reflective tape on the skin at five locations distributed on the upper arm, shoulder, back,

and neck using a 3D scanning laser vibrometer (Polytec, PSV-500) and using accelerometer

instrumented adapters wrapped on each wrist and the forehead with signals acquired via B&K

Pulse. The laser vibrometer and adapter measurements were synchronously referenced to the input

acceleration at the shaker handle

assembly. A sequence of seven shocks,

with four seconds between each shock,

was input and the laser focused on a single

measurement point for each trial. Two

trials were taken for each test treatment.

The last five shocks in each trial were used

in the data analysis. The peak magnitudes

over the five shocks were identified and

averaged. Then, the peak ratio was

calculated by dividing the mean peak with

the input peak measured on the handle.

Fig. 1. Subject postures and measurement locations.

X

1

4

2 3

Wrist Adapter

Y

Z

Page 57: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

57

Preliminary Results and Discussions

As examples, the input shock and the time-domain responses measured in the Z direction at the

eight locations are shown in Figure 2. Table 1 lists the mean peak ratios of the eight subjects

measured at the eight locations, which were calculated using the vector sum of the time-history

responses in the three orthogonal directions shown in Figure 1. As shown in the Figure and Table,

the shock responses generally decrease with the increase in the distance from the shock input point.

As the input shock from the handle was along the z direction, the response was also the greatest

along the z axis of the wrists, arm, shoulder, and back. However, the response was more prominent

in the vertical or Y direction for the head. This suggests that the shock input resulted in significant

rotational response of the head, which explains why there is substantial cross-axis response in the

Y direction. As also shown in Table 1, the coefficient of variation at each location was high among

the subjects. This suggests that the shock transmission in the upper extremities is individual-

specific.

Fig.2. Input shock from the handle and the responses at eight measurement

Table 1. The average peak ratios (of the eight subjects at eight measurement locations

Right Wrist Left Wrist Upper Arm Shoulder Left Back Right Back Neck Head

0.949 0.984 0.412 0.116 0.055 0.066 0.061 0.060

STD 0.186 0.120 0.158 0.039 0.017 0.020 0.014 0.015

CoV 0.20 0.12 0.38 0.34 0.30 0.30 0.23 0.26

References

1. Pope MH, Magnusson M, Hansson T. 1997. The upper extremity attenuates intermediate frequency vibrations.

J. Biomechanics. 30(2): 103-108.

Left Wrist

Acc

eler

ati

on

(m

/s2) Input Right Wrist

Shoulder Upper Arm Right Back

0 0.5 0 0.5 0 0.5

Time (s)

Head Neck Left Back

Page 58: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

58

DEVELOPMENT AND USE OF AN EXPERIMENTAL DEVICE INCLUDING A LASER SCANNING

VIBROMETER FOR MEASURING THE VIBRATION TRANSMISSIBILITY MAPPING ON THE

DORSUM OF HANDS GRIPPING A VIBRATING HANDLE

*Christophe Noël

Laboratoire de Modélisation des Systèmes Mécaniques de Prévention

Institut national de recherche et de sécurité (INRS)

1 rue du Morvan - CS 60027 - F-54519 VANDOEUVRE cedex,France

Introduction

Many experimental studies have been carried out by different research laboratories in order to assess the

biodynamic response of the upper limb exposed to vibrations.1 Indeed, this response provides a way to characterise

the changes of the mechanical stress and strain field occurring during the propagation of vibration and it has been

suggested that such modifications are likely to be responsible for the onset of hand-arm vibration syndrome.1 Previous

works succeeded in quantifying the influence of several factors like posture, push and grip forces on the dynamic

response of Hand-Arm system. Most of these measurements like for example the driving point mechanical impedance,

lead to evaluate the global behaviour of the upper limb. We propose in the following study to describe an original

experimental device for assessing the acceleration by using a scanning vibrometer2-3 at selected points of a measuring

mesh projected on the back of hand. Thus, we can estimate local dynamic responses, for instance expressed in terms

of acceleration transmissibility maps and then extract more accurate information from the spatial characteristics of the

vibration.4 Then, the method was implemented to analyse the effect of various parameters on the acceleration transfer

between a vibrating handle and the back of hand. Push and grip forces, postures, ambient temperature, handle

acceleration have been varied and the attenuation ability of antivibration glove materials have also been tested, but

only a few findings will be presented in this paper.

Methods

The overview of the experimental device is shown on Fig. 1(a). We developed a dedicated software to drive

the laser beam moved by two motorized mirrors and to set some laser parameters at the same time. Data were measured

with an acquisition unit plugged to a central laptop which moves the spot and triggers the measurement. This software

computes and projects the measurement mesh (around 100 nodes) directly onto the dorsum of the hand. For ensuring

a uniform acceleration in the contact area between the hand and the handle, the latter was designed so that its first

eigenfrequency was located far below the frequency band of interest. The handle sketched in Fig. 1(b), was

instrumented with sensors for measuring both static and dynamic push and grip forces and also with an accelerometer.

It was mounted on an electrodynamic shaker with a flat frequency response up to 800Hz. The screw connections were

minimized to increase the signal/noise ratio and so to improve the spectral coherence in high frequency. Moreover, in

order to ensure enough back-scattering laser light power, we covered the skin with a mix of glass micro beads and

body painting. This way was more convenient and effective than using common reflective tapes. Regarding

experimental protocol, the transmissibility maps were measured by third octave bands for 20 subjects aged from 18 to

39 and for 16 pairs of coupling forces defined as a percentage (5% to 50%) of the individual maximum static push

and grip effort. The posture is shown on Fig. 1(c). The handle acceleration spectral content was a broadband noise in

the frequency range [25Hz-500Hz] with a rms value of 15 m.s-2 (not ISO 5349 weighting). An inverse method using

the transfer function between the shaker electrical input and the handle acceleration was implemented to keep this

value constant for every subject and coupling forces.

Fig. 1: Experimental setup (a), instrumented handle with main dimensions (b) and posture selected in this paper (c)

(a) (c) (b)

Page 59: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

59

Results and Discussions

Two different approaches are considered to process the measurements. In the first approach the raw

transmissibility maps of every subject were analyzed to find out common trends. In the second approach, we used a

mathematical metrics (for example the geometric spatial average or the spatial spread/dispersion) in order to contract

the spatial information in a scalar and then perform statistical analysis. We present here only typical raw

transmissibility maps which highlight the influence of the parameters considered but all the conclusions drawn below

rely on a statistical study. The effect of the handle excitation frequency is illustrated on Fig. 2 for one particular subject

pushing and gripping the handle with a force respectively of 30% and 15% relative to his maximum achievable efforts.

In the third octave centered on 80 Hz, the transmissibility is quite uniform and much higher than 1. The hand

mechanical system translates like a solid body. At higher frequency the transmissibility maps become more and more

inhomogeneous and localized areas of higher level match the metacarpal bones (see for instance the third octave

centered on 500 Hz). On the contrary, the soft tissues are likely to better damp the vibration power since the

transmissibility is in these places much lower.

Fig. 2: Effect of frequency for a fixed coupling force : push@30% of push max - grip@15% of grip max

The effect of the coupling forces are investigated in the fixed third octave centered on 400 Hz. The transmissibility

maps are illustrated on Fig. 3 for 4 different pairs of push and grip force. The notation PxGy stands for x% of push

force and y% of grip force. The influence of the coupling force on the transmisssibility is clearly hihlighted here. Thus,

the higher the push and grip, the higher the transmissibility. Metacarpal bones still transmit most but the effect of push

and grip forces is visible even in the soft tissue areas. In fact, gripping or pushing changes the stiffness and the damping

properties of the soft tissues and then the way the vibration propagates.

Fig. 3: Effect of coupling forces for the fixed third octave centered on 400Hz

References

1. Dong, R.G., McDowell, T.W., Welcome, D.E. (2005). Biodynamic response at the palm of the human hand

subjected to a random vibration. Industrial Health 43(1): 241–255.

2. Rossi, G.L., Tomasini, E.P. (1995). Hand-arm vibration measurement by a laser scanning vibrometer.

Measurement 16(2): 113–124.

3. Concettoni, E., Griffin, M. (2009). The apparent mass and mechanical impedance of the hand and the transmission

of vibration to the fingers, hand, and arm. Journal of Sound and Vibration 325(3): 664–678.

4. Noël, C. (2011). Acceleration mapping and local biodynamic response of hand gripping a vibrating handle by

using laser scanning vibrometer. Buxton, Tuesday 20th to Wednesday 22nd September 2011. Buxton: Health &

Safety Laboratory. pp. 173–184.

Page 60: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

60

HAND-ARM VIBRATION TRANSMISSIBILITY MEASUREMENT FOR ASSESSING

HEARING IMPAIRMENT

*Enrico Marchetti+,++, Renata Sisto+,++, Alessandro Lunghi++, Floriana Sacco++, Filippo Sanjust++,

Raoul Di Giovanni++, Teresa Botti++, Angelo Tirabasso++

+SapienzaUniversità di Roma, Department of Physiology and Pharmacology “V. Erspamer”.

++National Institute for Insurance against Accidents at Work, Department of medicine,

epidemiology, workplace and environmental hygiene.

Introduction

Assessment of physical interaction between noise and vibration exposure in human

subjects requires accurate measurement of the amplitude and frequency of vibration that travels

from the entering point (the hand for hand-arm HA) to the head, with some insight in order to

enhance correlation. In this study preliminary data are reported, limited to the forearm.

This work is directed to measure transmissibility of the forearm related to mechanical vibration

entering from the hand. Moreover, the skin effect and the coupling with the vibration source are

kept into account.

Methods

Measurement of vibration input and output for the forearm (hand-arm exposure) are

performed by a laser Doppler interferometer (Polytec, Germany, EU). Simultaneous (in phase)

measurement of grip force are carried out. In order to evaluate the transmissibility, input vibration

signals are standardized. Transmissibility is evaluated from data. A wide frequency range is

selected to keep into account also higher order harmonics, eventually arising from Tonic Vibration

Reflex (TVR). Thirty-four young volunteers have been selected: 15 females and 19 males. MV on

the handle was elicited by an electrodynamic shaker (RMS SW 1508, Germany, EU) driven by a

controller (Vibration Research VR 7500-2, Michigan, USA) at frequencies ranging from 6 to 500

Hz, with a transmissibility resolution of less than 1 Hz. The signal had an overall 26.9 ms-2 r.m.s.

acceleration. In order to take into account interpersonal differences the grip force exerted (GF) was

expressed in terms of Maximum Voluntary Contraction (MVC). Three levels of grip force (20%,

30% and 40%) relative to personal MVC have been selected, as typical of workers activity. The

posture was standardized following the UNI EN ISO 10819 (1998) for glove testing. All signals

were transmitted and recorded on digital analyzer OROS OR38 (Oros, France, EU). Data analysis

have been performed off-line with ad hoc applications developed with MatLab Release 2008a

(Mathworks, Massachusets, USA).

Results

Results show some well-known (and some less known) forearm resonances. Skin effect is

absent, as the laser beam direction is set orthogonal to the skin in a spot where the skin is tightly

wrapped around muscle and bone. Transmissibility preserve frequencies but tends to alters

amplitude. A good amount of vibratory energy reaches the shoulder.

Page 61: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

61

Grip force level (MVC

percentage)

Transmissibility peak values in dB (and corresponding

frequency in Hz)

P1 P2 P3 P4

20 1.78 (8) 1.46 (24) -9.82 (61) -13.15 (87)

30 1.72 (8) 1.45 (29) -7.40 (63) -10.43 (87)

40 1.60 (8) 1.24 (34) -6.11 (64) -8.68 (88)

Conclusion

Comparison of actual data with those of other authors1,2 confirms that posture and force

are strong actors of the forearm response curve shaping, i.e. frequency transmissibility. The

method suggested in this work to match different muscular builds and genders is particularly

interesting because it is physiologically based on the functional stiffness that, supposedly, play a

paramount role in transmissibility. The observations referred in present paper suggest that the

resonances are the external evidence of some internal mechanical features of the hand-forearm

system. It is therefore a desirable perspective to develop a mechanical/digital model to elaborate

MV data on the hand in order to have theoretical MV on the elbow for every vibrating tool.

A good characterization of the vibration transmissibility to the head is essential for studying the

hearing effect due to simultaneous exposure to noise and vibration.

References

1. Sorensson A., Burtstrom L. (1997), Transmission of vibration energy to different parts of the

human hand-arm system, Int. Arch. Occup. Environ. Health, 70: 199-204.

2. Adewusi S.A., Rakheja S., Marcotte P., Boutin J. (2010), Vibration transmissibility

characteristics of the human hand–arm system under different postures, hand forces and

excitation levels. Journal of Sound and Vibration 329:2953–2971.

Page 62: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

62

A NEW METHODOLOGY FOR MEASURING VIBRATION TRANSMISSIBILITY

ON A GRIPPED HANDLE FOR HAVS RESEARCH

*Almaky Almagirby, Matt J. Carré, Jem A. Rongong

Department of Mechanical Engineering, The University of Sheffield, Sheffield UK

Introduction

Many types of hand-held vibrating tool, such as chain saws, grinders, drills, and chipping

hammers are widely used in several industries. Extended exposure to vibration transmitted from

some of these tools may cause hand-arm vibration syndrome (HAVS) 1. International Standards

includes guidelines for the measurement and evaluation of human exposure to vibrations in the

hand 2. However, limited research exists that directly measures transmitted vibration through the

hand. Determination of transmitted vibration often depends on modelling of the system. The

reliability of these models depends on their ability to fully represent the actual hand-tool system

and the accuracy of the measurements that are used for calibration and validation 3. The dynamic

response of the human hand behaves differently among individuals. The new methodology

presented here allows us to measure and evaluate vibration transmissibility for a human finger in

contact with different materials, whilst measuring and controlling the grip force.

Methods

The experimental rig was set up to carry out vibration measurement in a single direction

(vertical excitation). A 40 mm diameter rigid cylindrical handle, made from aluminium, was setup

to be excited as a free-free system, excited by a V406 shaker (LDS) via amplifier (see Figure 1).

A reference accelerometer is located directly on the top of the driving point and the response

accelerometer is mounted on the end that is gripped (on the right hand side Figures 1 and 2). The

right end of the testing handle is instrumented to measure a grip force ranging from 10 N to 50 N,

based on the design used in ISO-10819 (1996) 4. This design uses a split cylinder with a strain

gauged beam element. The grip force measurement system was calibrated over a range 0 to 100

N.

Figure 3: Vibration and grip force test rig set up

Figure 4: Experiment set up showing

gripping of handle

Page 63: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

63

National Instrument devices are used to drive the shaker and continuously display data on

the screen using LabVIEW software (version 2014). Frequency response functions (FRF) of the

system were collected from six positions along the handle length, using instrumented hammer

tests.

Results and Discussions

The FRF data obtained in each of six positions indicates that the dynamic system of the

handle has three modes at low frequencies (2, 11 and 17 Hz), and no other modes was present up

to a frequency of 550 Hz. (see Figure 3). A significant difference in FRF values were displayed at

two ends of the handle (position 1 and position 6) when compared with FRF values measured from

the middle position. This is thought to be due to rocking and twisting that occurs relative to the

shaker connection point. Overall, this study concluded that the new test rig is suitable for

measuring vibration transmissibility for HAV research. This is reasonable for testing vibration

transmissibility of gloves materials at frequencies ranging from 16 to 400 Hz, which are of

impotence to this research 4.

Figure 5: Frequency response function FRF for six position across the handle (left, 0 to 100 Hz;

right 100 to 1000 Hz)

References

1. Xu, X.S., Dong, R.G., Welcome, D. E., Warren, C., McDowell, T.W., An examination of the handheld

adapter approach for measuring hand-transmitted vibration exposure. Measurement, 2014. 47: p. 64-77.

2. ISO-5349-2, Mechanical vibration-Measurement and evaluation of human exposure to hand-transmitted

vibration. British standard, 2002.

3. Dong, R.G.Welcome, D.E., McDowell, T.W., and Wu, J.Z. Modeling of the biodynamic responses

distributed at the fingers and palm of the hand in three orthogonal directions. Journal of Sound and Vibration,

2013. 332(4): p. 1125-1140.

4. ISO-10819, Mechanical vibration and shock hand-arm vibration - Method for the measurement and

evaluation transmissibility of gloves at the palm fo the hand, in British standard. 1997.

Page 64: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

64

NONLINEARITIES IN THE BIODYNAMIC RESPONSE OF THE HAND-ARM

SYSTEM TO SINGLE-AXIS VIBRATION

*Marco Tarabini, Lan Xie, Bortolino Saggin, Diego Scaccabarozzi

Politecnico di Milano, Department of Mechanical Engineering

Via Previati 1/C, 23900 Lecco, Italy

Introduction

The biodynamic response of the hand-arm system to single-axis vibration has been

commonly studied using the linear estimators of the frequency response function1-4. Nevertheless,

a nonlinearity versus the vibration amplitude was observed at low frequencies. Tarabini et al.2

reported that, in presence of unknown vibration direction, the vibration level affected the

impedance phase at low frequencies (octave band centered at 16 Hz), while the impedance

modulus variation was comparable to the tests variability. Burstrom evidenced a complex

dependence of the impedance magnitude from the vibration level5. The influence of different

velocity levels on the phase of the impedance was not statistically significant for any of the

directions.

In the existing literature studies, the biodynamic response have always been studied using

the linear estimators of the frequency response function6. In presence of nonlinear effects, the

linear estimators (power spectral density and cross-spectral density, PSD and CSD) of the FRF are

biased. The hypothesis of linearity is commonly verified by comparing the PSD and the CSD or

by analyzing the coherence function. Low coherence values are due to system nonlinearities, i.e.

to the lack of homogeneity or additivity or to the variation of modal parameters in time7,8.

Methods

This paper analyzes the response of the hand-arm system to vibration using the modelling

a nonlinear single input, single output system as a multiple input, single output system with

nonlinear inputs. If the hand-arm response to vibration is nonlinear, the force dependence from the

vibration is the sum of a linear function and of linear responses to nonlinear functions (quadratic,

cubic and modulus) of the input, as shown in Figure 6.

Figure 6 Proposed nonlinear model

The mechanical impedance of the hand-arm system has been measured by imposing a

vertical vibration to an instrumented handle. The experimental setup and the test protocol are

H1y(f)

H2y(f)

H3y(f)

squared

cubed

x(t)

x(t)

x² (t)

x³ (t)

y1(t)

y2(t)

y3(t)

+

N(t)

y(t)

HMy(f)abs|x|(t) yM(t)

...

Page 65: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

65

described in ref. [2]. Eight subjects were asked to grip the handle with different shoulder, elbow

and wrist angles, exerting different push and grip forces, entailing different angles between the

vibration direction and the ISO 10068 reference axes. The response to vibration was modelled

using linear frequency response functions of the stimulus v, v2, v3 and |v|. The benefits deriving

from the adoption of a nonlinear model were assessed by comparing the conditioned response to

vibration using linear and nonlinear estimators and comparing the ordinary coherence with the

multiple coherence function. The importance of quadratic and cubic terms was evaluated by

comparing the conditioned response to the measured one, i.e. by analyzing N(t).

Results and Discussions

Experimental results evidenced that the introduction of the nonlinear terms increases the

coherence function especially in the low frequency region; two examples (Figure 7). Benefits

deriving from the adoption of a nonlinear model are more evident when the forearm is aligned

with the vibration direction and are expected to be relevant in case of response of the hand-arm to

shocks and transient vibration.

Figure 7 Comparison between the ordinary coherence (black line) and the conditioned coherence (red line). Dotted

lines indicate the SD of tests performed by different subjects.

References

1. Y. Aldien, P. Marcotte, S. Rakheja and P. E. Boileau, "Influence of hand-arm posture on biodynamic response

of the human hand-arm exposed to zh-axis vibration," International Journal of Industrial Ergonomics, vol. 36,

pp. 45-59, 2006.

2. M. Tarabini, B. Saggin, D. Scaccabarozzi and G. Moschioni, "Hand-arm mechanical impedance in presence of

unknown vibration direction," Int. J. Ind. Ergonomics, vol. 43, pp. 52-61, 2013.

3. Y. Aldien, P. Marcotte, S. Rakheja and P. Boileau, "Mechanical Impedance and Absorbed Power of Hand-Arm

under xh-Axis Vibration and Role of Hand Forces and Posture," Industrial Health, vol. 43, pp. 495-508, 2005.

4. P. Marcotte, Y. Aldien, P. E. Boileau, S. Rakheja and J. Boutin, "Effect of handle size and hand-handle contact

force on the biodynamic response of the hand-arm system under zh-axis vibration," Journal of Sound and

Vibration, vol. 283, pp. 1071-1091, 2005.

5. L. Burström, "The influence of biodynamic factors on the mechanical impedance of the hand and arm,"

International Archives of Occupational and Environmental Health, vol. 69, pp. 437-446, 1997.

6. J. S. Bendat and A. G. Piersol, Random Data: Analysis and Measurement Procedures. John Wiley & Sons, Inc.

New York, NY, USA, 1990.

7. M. Tarabini, S. Solbiati, G. Moschioni, B. Saggin and D. Scaccabarozzi, "Analysis of non-linear response of the

human body to vertical whole-body vibration," Ergonomics, pp. 1-13, 2014.

8. J. S. Bendat, Nonlinear System Analysis and Identification from Random Data. Wiley New York etc., 1990.

0.75

0.8

0.85

0.9

0.95

1

10 100

Co

her

ence

Frequency [Hz]

0.75

0.8

0.85

0.9

0.95

1

10 100

Co

her

ence

Frequency [Hz]

Page 66: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

66

Session VI: Computer Modeling and Analysis

Chairs: Pierre Lemerle and Subhash Rakheja

Presenter Title and authors Page

Yue Hua A growth model of small artery for the vibration induced

Raynaud syndrome situation

Yue Hua, Pierre Lemerle, Jean-François Jean-François

Ganghoffer

67

John Z. Wu Three-dimensional finite element modeling of the effects

of gripping force on finger vibration transmissibility

John Z. Wu, Ren G. Dong, Daniel E. Welcome, Thomas

W. McDowell

69

Christophe Noël Validation of a 3d visco-hyper-elastic finite element

model for a pre-stressed vibrated distal forefinger

phalanx: mechanical and first thermal analysis

Christophe Noël

71

Shu Wang Biomechanical bent-arm model of the hand-arm system

coupled with an anti-vibration glove

Shu Wang, Subhash Rakheja, Paul-Émile Boileau

73

Sebastian Mangold The influence of the user on the power tool functionality -

a force sensing handle for a hammer drill

Sven Matthiesen, Sebastian Mangold, Tim Bruchmueller,

Daniel Stelzer, Bernhard Truenkle

75

Sven Matthiesen

A method to develop hand-arm models for single impulse

stimulation

Sven Matthiesen, Sebastian Mangold, Tobias Schäfer,

Sebastian Schmidt

77

René Germann A method to design a hand arm model with translational

and rotational degree of freedom for high accelerated

applications

Sven Matthiesen , René Germann, Sebastian Mangold

79

Page 67: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

67

A GROWTH MODEL OF SMALL ARTERY FOR THE VIBRATION-INDUCED

RAYNAUD SYNDROME SITUATION

*Yue HUA+, Pierre LEMERLE+, Jean-François GANGHOFFER++ +Laboratoire de Modélisation des Systèmes Mécaniques de Prévention, Institut national de recherche et de

sécurité, 1 rue du Morvan, Vandœuvre-lès-Nancy, 54519 Cedex, France ++Laboratoire d’Energétique et de Mécanique Théorique et Appliquée , UMR 7563, Université de Lorraine, 2

avenue de la forêt de Haye, 54502 Vandœuvre-lès-Nancy, France

Introduction

Hand-arm Vibration Syndrome (HAVS) originates from the use of hand-held power tools. With respect to

higher frequency vibrating tools (>50 Hz), HAVS is generally known as peripheral circulatory disorders in the hand.

It is basically caused by an abnormally strong vasoconstriction of blood vessels. Past studies suggest that a reduction

of lumen of the blood vessels in Vibration White Finger subjects, because of either hypertrophy or thickening of the

vessel wall, would be responsible of the disease1,2. But how the load of the hand-held tools affects the structure of

blood vessels, in a direct (vascular impairment) or indirect ways (as a result of neurological damage), is still

controversial3. In this paper, a mechano-biological relationship type is assumed and we aim to construct a growth

model of small arteries capable of predicting the structure changes of the arterial wall in function of the vibration

exposure.

Method

We use the Continuum Mechanics approach for the modeling of small artery growth. The governing

equations are based on the kinematics of finite growth combined with the framework of open system thermodynamics.

We introduce an intermediate configuration without any elastic deformation for finite growth and the deformation

gradient was multiplicatively decomposed into a reversible elastic part (elastic deformation gradient) and an

irreversible growth part (growth deformation gradient), which was first used to describe the growth of biological

tissues by Rodriguez et al. (1994)4. To compute the growth processes, the growth gradient of deformation is considered

as an internal scalar variable and computed locally at each integration point level and each instant, by the equation of

volume growth law proposed by Kuhl et al. (2007)5.

The artery is modeled as a long tube with a nonlinear hyper elastic material.

The theory of plane deformation is used to solve the problem in 2D. In reality, using

hand-held power tools induces high pressure levels in the finger tissues. We know

through the optical research of Masato Ohmi (2013)6 that the artery deforms and

becomes elliptic when the finger is pressed against a glass plate (fig. 1), which is

comparable with tool gripping conditions. Hence, at the artery scale, these conditions

are modeled with a pressure applied symmetrically on the outer surface. The loading

is divided in 4 stages: quasi-static compression– small vibration – quasi-static release–

unloading (fig. 2).

The elastic material parameters of the tube wall are chosen as λ = 1.43 MPa and µ = 0.357 MPa (Lamé

coefficients), which correspond to a Poisson’s 0.4 and a Young’s modulus of 1MPa7. The dimensions of the small

artery were estimated from the optical research of Masato Ohmi (2013)6. The outer and inner radii are chosen as 0.5

mm and 0.375 mm respectively.

Fig.1: OCT image of a

small artery when the

finger is pressed

against a glass plate6

P

P

Fig.2: Load application

and process description

Page 68: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

68

Results and Discussions

The results presented in the following are based on simulations carried out with FreeFEM ++, which is a free

open source partial differential equations solver. Thanks to symmetries along the X and Y axes, only ¼ of the structure

needs to be modeled with suitable boundary conditions.

Fig. 3 shows the mesh and the deformed shape of ¼ artery; it illustrates the spatio-temporal evolution of

volume growth gradient of deformation (color scale). The load was applied by incremental steps in a large strain

approach. At instant 𝑡 = 𝑡0+, the artery deforms due to the mechanical loading. The initial growth gradients of

deformation equal unity. Then the growth starts in the outer part of the free lobe, where the stress is the largest. At

this location and at 𝑡 = 𝑡0+, the thickness of the artery increases from 0.125mm to 0.146mm. At 𝑡 = 𝑡1

+, when the load

is released, the artery cannot deform back to its initial shape and due to the growth localized in the outer part of the

lobe, the inner part is subjected to high stress during the unloading stage. As a result, the inner area begins to growth.

Finally, we obtain a thickness of 0.147mm, i.e. about 17.6% more than the initial thickness. The asymmetric loading

leads to an asymmetric irreversible growth and finally to an asymmetric shape.

Although the proposed model qualitatively reports the thickening of a small artery wall under the asymmetric

compressive oscillatory stress, many items still need some improvement. First, more realistic constitutive models for

the artery have to be adopted, which in reality consists of three nearly incompressible layers, including a residual stress

in the artery wall and a spatio-temporal blood pressure law. In Kuhl’s model, the relaxation time of the growth process

is governed by two parameters. As the original approach addressed the prediction of the final state at biological

equilibrium (for instance driven by the long-term high blood pressure effects), no validated values or estimates were

required. In our problem, this is no longer correct as clearly two timescales are playing a role, the growth time constant

and the characteristic time of the excitation, namely the vibration period. However, in the case study illustrated above,

the growth is mainly due to the static load, as the model is driven by the stress-state (and 𝑃 ≈ 𝑃0 over time). In the

next step of our research, we aim to extract information regarding these quantities from published experimental

studies, by means of tuning methods. It seems the most exploitable observations have been obtained from tests carried

out on animals.

Reference 1 Gemne, G. (1994). Pathophysiology of white fingers in workers using hand-held vibrating tools. Nagoya J Med Sci. 57

(Suppl.), pp. 87-97.

2 Hashiguchi T., Yanagi H., Kinugawa Y., Sakakibara H., Yamada S. (1994). Pathological changes of finger and toe in patients

with vibration syndrome. Nagoya J Med Sci., vol. 57(Suppl.), pp.129-136.

3 Stoyeva Z., Lyapina M., Tzvetkov D. Vodenicharov E. (2003). Current pathophysiological views on vibration-induced

Raynaud's phenomenon. Cardiovascular Research, 57 (3), 615-624.

4 Rodriguez E.K., Hoger A., McCulloch A.D. (1994). Stress-dependent finite growth in soft elastic tissues. J Biomech, vol.27,

pp.455-467.

5 Kuhl E, Maas R, Himpel G, Menzel A. (2007). Computational modeling of arterial wall growth. Attempts towards patient-

specific simulations based on computer tomography. Biomech Model Mechanobiol, vol.6, pp.321-331.

6 Ohmi M., Kuwabara M., Haruna M. (2013). Dynamic imaging of a small artery underneath skin surface of a human finger by

optical coherence tomography. J. Biomedical Science and Engineering, vol.6, pp.249-252.

7 Langewouters G.J., Zwart A., Busse R., Wesseling K.H. (1986). Pressure-Diameter Relationships of segments of human finger

arteries. Clinical Physics and Physiology Measurement, vol.7, pp.43-55.

Acknowledgments: The authors would like to express their appreciation for all advice and comments received from Christophe Noël (INRS) and

Gérard Maurice (Université de Lorraine).

Fig.3 Deformed shape of a ¼ artery and evolution of growth at 𝑡 = 𝑡0+ ; 𝑡 = 𝑡1

−; 𝑡 = 𝑡1

+; 𝑡 = 𝑡2 (from left to right)

t=t1 t=t1

Page 69: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

69

THREE-DIMENSIONAL FINITE ELEMENT MODELING OF THE EFFECTS OF

GRIPPING FORCE ON FINGER VIBRATION TRANSMISSIBILITY

*John Z. Wu, Ren G. Dong, Daniel E. Welcome, Thomas W. McDowell

Engineering and Control Technology Branch, Health Effects Laboratory Division,

National Institute for Occupational Safety & Health, Morgantown, WV, USA

Introduction

Mechanical stress and strain in the soft tissues -- the essential factors that modulate the

growth, remodeling, morphogenesis of the biological system -- have been proposed to be

associated with the initiation and development of the hand-arm vibration syndrome1. However, the

vibration induced dynamic stress and strain in living tissues cannot be determined by using either

experimental methods or traditional lumped mass models2. In the current study, we proposed a

hybrid modeling method to analyze the biodynamic responses of the finger when gripping a

vibrating cylindrical tool handle.

Methods

The 3D finite element (FE) gripping model features a finger and a cylindrical handle (Fig.

1A-B). The model includes three finger segments (distal, middle, and proximal phalanges), three

joints [the distal interphalangeal (DIP), proximal interphalangeal (PIP), and metacarpophalangeal

(MCP) joint], and contains the major anatomical substructures of the finger (i.e., soft tissues, nail,

and bone)3. The cylinder (d = 40 mm) was considered of aluminum and covered with thermoplastic

materials (thickness 1.5 mm). The coupling of the local and global dynamic responses is

considered by introducing lumped parameters2. The effective mass of the hand-arm is represented

by the mass element M at the MCP joint. The coupling between hand, forearm, and ground is

represented using three sets of spring/damping units (ki and ci, i=1,2,3), which are linked to the

ground in x, y, and z direction. The coupling effect between the palm and cylinder is represented

by another spring/damping unit (k4 and c4), which links the MCP joint center to the cylinder center.

The bone and nail are considered as linearly elastic, whereas the soft tissues are considered as

hyperelastic and viscoelastic4. The nonlinearly elastic behaviors are characterized by using a two-

term Mooney-Rivlin model, whereas the viscoelastic properties are formulated using a three-term

Prony-series model in the frequency-domain. In addition, the Rayleigh formula is introduced to

include the tissues’ frequency-dependent viscous damping5. The model parameters were

determined by fitting the model to experimental measurements6. The simulations were

accomplished in two stages. First, the finger was deformed under static gripping, which was

Figure 1. Gripping model.

A: Finite element modeling

of a finger. B: Hybrid model

of gripping vibration. The

model was constructed

using a commercially

available FE software

ABAQUS.

Page 70: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

70

realized by applying moments at the DIP, PIP, and MCP joints; the joint moments represent the

musculoskeletal forces during gripping. Secondly, vibratory loading was applied at the cylinder

center, which represents tool vibration, such that the finger vibrates at the deformed states.

Results and Discussions

Fig. 2A shows the simulated static contact pressure on the soft tissues of the finger when

the hand grip force reached approximately 30N and before the vibratory loading was applied on

the cylinder. According to the model predictions, the maximal tissue stress is manifested in the

middle finger segment, which is different from those observed in the power gripping tests3. The

simulated frequency-dependent vibration transmissibility of the finger segments is illustrated in

Fig. 2B. The transmissibility shown is the total transmissibility that included the vibrations in all

three directions. The results indicate that resonant frequencies at the distal, middle, and proximal

segments are 115 Hz, 105 Hz, and 88 Hz, respectively. The corresponding transmissibility

magnitude increases slightly from the distal to the middle and to the proximal segments. The

resonant frequency increases with increasing grip force (results not shown). The general trends of

the finger vibration characteristics predicted using the proposed model agree well with those

measured experimentally6. Using the proposed model, the coupling effects among the muscle

forces and the vibrations of the soft tissues of the finger and the global hand-arm system can be

naturally simulated.

References

1. Dong RG, Welcome DE, McDowell TW, Xu XS, Krajnak K, and Wu JZ, 2012. A proposed theory on biodynamic

frequency weighting for hand-transmitted vibration exposure, Industrial Health 50(5): 412-424.

2. Dong RG, Dong JH, Wu JZ, Rakheja S. 2007. Modeling of biodynamic responses distributed at the fingers and

the palm of the human hand-arm system. J Biomech. 40:2335-40.

3. Wu JZ, Dong RG, Warren CM, Welcome DE, McDowell TW. 2014. Analysis of the effects of surface stiffness

on the contact interaction between a finger and a cylindrical handle using a three-dimensional hybrid model. Med

Eng Phys. 36:831-41.

4. Wu JZ, Dong RG, Smutz WP, Schopper AW. 2003. Nonlinear and viscoelastic characteristics of skin under

compression: experiment and analysis. Biomed Mater Eng. 13:373-85.

5. Wu JZ, Dong RG, Welcome DE. 2006. Analysis of the point mechanical impedance of fingerpad in vibration.

Med Eng Phys. 28:816-26.

6. Welcome DE, Dong RG, Xu XS, Warren CM, McDowell TW. 2014. The effects of vibration-reducing gloves on

finger vibration. Int J Indus Ergon. 44:45-59.

Figure 2: Predicted static contact pressure and transmissibility of the finger segments. A: Distribution of the

contact pressure on the soft tissues. B: Predicted transmissibility of the finger segments. DIS, MID, and PRO

represent the distal, middle, and proximal segment of the finger.

Page 71: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

71

VALIDATION OF A 3D VISCO-HYPER-ELASTIC FINITE ELEMENT MODEL FOR A PRE-STRESSED

VIBRATED DISTAL FOREFINGER PHALANX: MECHANICAL AND FIRST THERMAL ANALYSIS

*Christophe Noël

Laboratoire de Modélisation des Systèmes Mécaniques de Prévention

Institut national de recherche et de sécurité (INRS)

1 rue du Morvan - CS 60027 - F-54519 VANDOEUVRE cedex, France

Introduction

Extensive exposure of the hand-arm system to regular vibration can lead to various disorders and injuries due

in part to changes of mechanical quantities like dynamic stress or strain arising from the propagation of such vibration.1

Nowadays the direct measurement of this biodynamic response inside soft tissues is still a great issue, thereby finite

element models have been developed in order to assess the dynamic mechanical variables by numerical computation.2

Despite previous modelling approaches succeeded in reproducing qualitative observations, they have not been fully

correlated with experimental data. Our work aims at establishing and verifying a reliable high fidelity 3D finite

element model allowing the simulation of mechanical and thermal effects generated by vibration transmitted to a

statically preloaded distal forefinger phalanx. In particular, we wish to identify both the most suitable hyper-elastic

and damping behaviour laws and their related parameters which best fit measured static and dynamic finger’s stiffness.

A special attention was paid to the choice of a physiological and phenomenological damping law relevant for soft

tissues since damping is directly linked to the dissipated mechanical power3 which could be partly responsible for the

onset of hand-arm vibration syndromes.1-2

Methods

Both static and dynamic finger’s rigidities were measured

for 20 subjects aged from 19 to 39 with normal cutaneous sensory

threshold (monofilament size 3.61 in the Semmes-Weinstein test).

Each subject was advised to place its forefinger distal phalanx nail

on a specific support as depicted on Fig. 1. The static stiffness was

then measured thanks to a force sensor and a laser telemeter by

loading the finger with the contact indenter. The dynamic stiffness

modulus and the phase were next valued in the frequency band

[25Hz-500Hz] with an impedance head and a force sensor for compression levels corresponding to static stiffness of

8 N.mm-1 and 10 N.mm-1. The experimental setup was checked by measuring the pure real stiffness of a spring and

by comparison with data acquired for polyurethane foam and soft rubber on a commercial dynamic mechanical

analysis (DMA) tester.

Regarding modelling, as shown in Fig. 2 a 3D geometry and associated tetrahedral meshes (5072 nodes,

19676 meshes) were built for an index finger with the following anatomical elements: nail, bones for the distal-middle-

proximal (half) phalanges, interphalangeal articular cartilage and surrounding homogeneous skin and subcutaneous

tissues. Boundary conditions and dimensions (average lengths of subjects for

outer sizes and inferred from morphological rules4 for inner dimensions) are

summed up on Fig. 2. Bones, nail and cartilage are modelled as standard

linear solids (Zener model) with parameters coming from bibliography.5 Soft

tissue visco-hyper-elastic laws and parameters were identified by splitting

the whole issue in two steps. Firstly, we have dealt solely with the non-

viscous elastic behaviour law. The Ogden-Hill law was tested the most

suitable compressible constitutive law. The inherent parameters were then

identified by using a non-linear data-fitting algorithm between measured and

computed static stiffness. Our work main contribution is based on the way to take into account damping properties.

Starting from the well-known quasi-linear viscoelasticity3-5 theory, the second Piola-Kirchhoff stress tensor can be re-

written in the spectral domain for the case of an infinitesimal harmonic strain around a large static deformation. In this

way, this stress tensor is composed as the product of a tensor related to the static state and a complex function of

frequency describing the damping behaviour. The resulting mathematical form is therefore quite similar to that used

in conventional linear viscoelasticity and thereby it is a mean to use the infinite variety of linear damping models.

Many of such models have been implemented (rheological or fractional derivative models) but those based on the

Fig. 1: Experimental apparatus

Fig. 2: Modelling settings

Page 72: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

72

decomposition of relaxation functions as continuous sum of relaxation spectra3 have led to the best results possibly

because many of them are based on physiological background. Damping parameters are determined by minimizing

the gap (magnitude and phase) between the numerical and the experimental dynamic stiffness.

Results and Discussions

For the hyper-elastic static step, we chose an Ogden-Hill law of order one namely with three physical

parameters which were identified as explained previously. As shown on Fig. 3(a), we selected as comparison metric

the static stiffness derivative in function of the static stiffness. The gap between the simulations and the measurements

is really tiny around a few per cent and remains always inside the bounds of the 95% inter-subjects confidence interval.

As regards damping properties, we used as relaxation spectrum the box spectrum function most adapted for biological

soft tissues containing collagen fibres such as skin.5 Measured dynamic stiffness around preload corresponding to a

static stiffness of 10 N.mm-1 was selected for the parameters identification process. As drawn on Fig. 3(b), simulations

are in good agreement with experimental data. Mainly, numerical results well highlight the stiffness gradual rise up

to 100 Hz with steeper slope at higher frequencies. Moreover, the stiffness was computed at a pre-stressed of 8 N.mm-

1 and remains very close to measured data. This confirms that our model is sufficiently accurate and predictive.

Fig. 3: Comparison of experimental and computational static (a) and dynamic (b) stiffness

As a first application displayed on Fig. 4(a), we computed the average of the mechanical power density dissipated

during one cycle when the forefinger is vibrated by a single harmonic excitation at 100 Hz with acceleration amplitude

of 40 m.s-2 (usual grinder). The maximum power density is around 1mW.mm-3, localized in the vibrated area width

and spreads up to the bone. This mechanical dissipated power density can be introduced as an external heat source in

Pennes bioheat5 equation which models the heat transfer in living tissues by taking into account the heat generated

both by the blood flow and the metabolism. Therefore as depicted in Fig. 4(b), the temperature field induced by

previous vibration can be computed. For an exposure time of 10 min and surrounding air at 23 °C, it reaches a

maximum of 38.5 °C in the same area as the higher mechanical power. Even though this temperature is not high

enough to cause direct damages (collagen denaturation), it has been shown that a moderate increase could nevertheless

lead to changes in the rate of biochemical reactions including enzymatic or cellular activities.5

Fig. 4: Mechanical power density (a) - logarithmic scale [mW.mm-3] and induced temperature [°C] field (b)

References

1. Burns, T., Breathnach, S., Cox, N., Griffiths, C. (2010). Rook’s textbook of dermatology. Chichester, Wiley.

2. Wu, J.Z., Dong, R.G., Welcome, D.E., Xu, X.S. (2010). A method for analyzing vibration power absorption

density in human fingertip. Journal of Sound and Vibration 329: 5600–5614.

3. Lakes, R. (2009). Viscoelastic materials. New York, Cambridge University Press.

4. Schmidt, H.-M., Lanz, U. (2004). Surgical anatomy of the hand. Stuttgart, Thieme-Verlag.

5. Xu, F., Lu, T. (2011). Introduction to skin biothermomechanics and thermal pain. Berlin, Springer-Verlag.

2 4 6 8 100

5

10

15

20

25

30

Static stiffness [N.mm-1]

Sta

tic s

tiffness d

erivative [N

.mm

-2]

Modelling

Experimental

95% confidence interval

25 31.540 50 63 80 100 125 160 200 250 315 400 500 0

10

20

30

40

50

60

70

Frequency [Hz]

Dynam

ic s

tifn

ess m

agnitude [N

.mm

-1]

Modelling@pre-stressed=10N.mm-1

Experimental@pre-stressed=10N.mm-1

Modelling@pre-stressed=8N.mm-1

Experimental@pre-stressed=8N.mm-1

(a) (b)

(a) (b)

Page 73: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

73

BIOMECHANICAL BENT-ARM MODEL OF THE HAND-ARM SYSTEM COUPLED

WITH AN ANTI-VIBRATION GLOVE

*Shu Wang+, Subhash Rakheja+, Paul-Emile Boileau++

+Concave Research Centre, Concordia University, Montreal, QC, Canada ++IRSST, Montreal, QC, Canada

Introduction

The control of hand-transmitted vibration (HTV) can be realized through isolating hands

from vibrating tool handles. Gloves with different vibration isolation materials have been widely

proposed to obtain some degree of vibration suppression. Air bladder glove is one of the anti-

vibration gloves for which the air enclosed in tiny bladders provides vibration isolation effect

between hands and the tool handle in specific frequency ranges. In this paper, an air bladder anti-

vibration glove model proposed in [1] is integrated to a biomechanical bent-arm model of hand-

arm system (HAS) proposed in [2] to investigate its vibration isolation effectiveness.

Methods

Figure 1(a) shows the coupled gloved hand-arm-tool system model, for analysis of the

vibration responses along the 𝑧ℎ- axis. The model reported for the bent-arm posture was formulated

and analyzed to assess its suitability for application to a percussion tool model, shown in Fig. 1(b).

The responses of the HAS model coupled with the tool were assessed in terms of its ability to

predict measured driving-point mechanical impedance (DPMI) and vibration transmissibility

responses near the wrist, elbow and the shoulder joints, and dynamic responses of the tool.

Furthermore, the suitability of the HAS model was assessed by determining its static deflections

under two different levels of static push force (50 N and 75 N).

(a) (b)

Figure 1: (a) Gloved hand-arm-tool model in bent-arm posture; and (b) percussion tool model

The parameters of the HAS model associated with different push forces (50 N and 75 N)

and a constant grip force of 30 N were identified by minimizing a weighted sum of errors between

the model and measured DPMI and vibration transmissibility responses [2]. The baseline

parameters for the air glove model were taken as those reported in [1]. The measured DPMI

responses, corresponding to 50 N and 75 N push, respectively, and 30 N grip force were attained

Page 74: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

74

through laboratory tests with six male subjects. The measured data were extracted using broad

band zh-axis vibration in the 2.5 to 500 Hz frequency range (frequency-weighted rms acceleration

= 5.25 ms-2). The zh-axis vibration transmissibility responses distributed in the hand- arm system

were obtained through solutions of the equations of motion for the bent-arm model. For instance

the vibration transmissibility response at the wrist, Tw(jω) at excitation frequency ɷ was obtained

from the motion response magnitudes of the palm mass Zp and handle Zc, such that:

(1)

Results and Discussions

Figure 2 shows the comparisons of the vibration transmissibility responses at the wrist of

the bent-arm model with and without the anti-vibration glove with the mean measured data of the

bare hand corresponding to two different levels of the push force (50 N and 75 N) and constant

grip force of 30 N. Although some differences are noted, particularly for higher push force, the

bent-arm model yields generally good agreements with the mean measured data for bare hand. The

comparisons of the vibration transmissibility of the bare-hand and the gloved hand models suggest

that the addition of anti-vibration glove tends to amplify vibration slightly around the primary peak

near 12 Hz. The glove, however, tends to attenuate palm vibration in the 32 to 100 Hz frequency

range. Similar trends are also evident in the model responses under 30 N grip and 75 N push forces,

for which peak amplification is seen to occur around 14 Hz. The results suggest that the anti-

vibration glove considered may not yield effective vibration protection for the operators exposed

to the low-frequency power tool, but could provide attenuation of medium frequency vibration

transmitted to the hand, particularly at higher push force. The palm vibration isolation could be

enhanced by reducing the glove stiffness, which would likely lead to thicker isolation material and

loss of dexterity. The gloves also showed considerably higher vibration transmission to the fingers.

Figure 2: Comparisons of 𝑧ℎ-axis vibration transmissibility responses of the bare and gloved

hand-arm models at the wrist with the mean measured responses of the bare hand: a) 50 N push,

30 N grip forces; b) 75 N push, 30 N grip forces.

References

1. Dong, R.G., McDowell, T.W., Welcome, D.E., Warren, C., Wu, J.Z., Rakheja, S., 2009. Analysis of anti-vibration

gloves mechanism and evaluation methods. J. sound and Vibration, 321, 435-453.

2. Adewusi S., 2009. Distributed biodynamic characteristics of the human hand-arm system coupled with vibrating

handles and power tools. Ph.D. thesis, Montreal, Concordia University.

( )( )

( )

p

w

c

Z jT j

Z j

(a) (b)

Page 75: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

75

THE INFLUENCE OF THE USER ON THE POWER TOOL FUNCTIONALITY

- A FORCE SENSING HANDLE FOR A HAMMER DRILL -

Sven Matthiesen, *Sebastian Mangold, Tim Bruchmueller, Daniel Stelzer, Bernhard Truenkle

IPEK – Institute of Product Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany

Introduction

This paper presents an approach to investigate the influence of the user’s posture, grip force and push force

on the functionality – feed rate per time – of a hammer drill.

The continuous comparison between required and achieved product functions - known as validation - is one

of the key activities within the product development process. In the case of power tools, these product functions depend

on the one hand on the interactions between the user and the power tool, and on the other hand on the interactions

between the power tool and its application1. Therefore, in validation activities, it is necessary to understand the power

tool as a super system consisting of these three aggregated subsystems. In power tool development most validation

activities take place in test centers. Testing conditions, defined by the product developers, are usually very strict in

order to overcome the uncertainties caused by the complex interactions of the power tool with applications and users.

Anyway, the quality of power tool validation is still limited by the heterogeneous interactions between user and power

tool. This heterogeneity may lead to variant drilling effectiveness (feed rate per time) of a newly designed hammer

mechanism in a hammer drill prototype. This unclear influence on the technical system is problematic for the designers

because they cannot validate the effectiveness of their product improvement. To overcome this uncertainty,

mechanical analogous systems on test rigs may replace the individual human user. Therefore, the dynamic reaction of

user’s hand-arm movements has to be equivalent to that of the mechanical analogous system2. Unfortunately hand-

arm-models are usually designed to consider the same vibration on a power tool handle as a hand-arm-system. The

functionality of the super system consisting of the power tool, the user and the application hasn’t been included in the

modeling of hand-arm-models, yet. Additionally, it is difficult to apply and adjust the required push force on the power

tool under sufficient static deflection of the model’s masses.3

It is well known that a user’s posture, grip force and push force have distinct influences and have to be

included in the analysis of the dynamic behavior of the hand-arm-system. To develop a test rig for feed rate

measurement it is necessary to understand which of the mentioned parameters have to be considered in the

development of a sufficient hand-arm-model. This paper presents a force sensing handle for hammer drills and

discusses the various parameters influencing the feed rate. Based on this handle it will be possible to evaluate hand-

arm-models on their ability to induce user-like forces on a power tool handle of an operating hammer drill.

Methods

Figure 1 (left) displays the modified hammer drill with its force sensing handle. Figure 1 (right) displays the

schematic setup of the modified hammer drill with all its sensors, numbered from 1 to 6.

Fig.1: Modified hammer drill and schematic force sensing handle

The force sensing handle is connected by piezoelectric force transducers (1 and 2) with the housing of the hammer

drill. The single axis force transducer in the upper connection (1) allows the measurement of the dynamic force in the

direction of hammering action. The bottom force transducer (2) measures in two directions – the hammering direction

and the tangential direction relative to the drilling axis. Both sensors are preloaded and therefore capable of detecting

the dynamic pulling and compression forces simultaneously on the top and bottom of the user’s hand. Next to the

force transducers, towards the hand of the user, two tri-axial accelerometers (4 and 5) allow the measurement of the

Page 76: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

76

acceleration forces in the axial direction of the hammer action and tangential to the drilling axis. The hand enclosed

area of the force sensing handle contains a customized grip force measurement device (3). The handle is split in half

and connected through a three point bending beam applied with four strain gauges. Grip forces in the direction of the

hammer action can be measured but orthogonal ratios cannot be detected. To evaluate the drilling process a laser

distance sensor (6) measures the feed rate of the hammer drill. The laser beam points onto the tip of the drill to reduce

inaccuracies caused by angular changes during the drilling process.

The functionality of the power tool is quantified through the feed rate (distance per second) while hammer

drilling concrete. To investigate the user’s influence on the power tool functionality an explorative study with one

male user was conducted. The user was asked to drill holes with one hand in two postures (displayed in figure 2) by

holding push force and grip force as constant as possible. In order to do so, the push and grip force was displayed to

the user with a sample rate of 2 Hz. The posture was observed and controlled by a visual comparison between shown

postures in figure 2 and a web cam live stream. For each posture configuration, using two grip forces and two push

forces, the feed rate was measured in ten trials. The range of a reasonable push force variation was identified through

a screening test measuring the push force of several male and female users.

Results

In Figure 2 the measured feed rate is displayed depending on the push force, grip force and posture for the

best five trials (push force and grip force within 10% variation). The bar chart shows the average feed rate. The

variance of the five best trials is shown by the black line within this plot.

Fig. 2: Measured feed rate while hammer drilling depending on push force, grip force and posture

The push force has a large influence on the hammer drill’s feed rate and therefore on the hammer drill’s

functionality. In contrast, the different postures and grip forces have no substantial influence on the feed rate. The

measured push force in the screening test was in the range between 50 N and 300 N. As a result of this investigation

it can be stated that a test rig hand-arm-model for feed rate measurement of hammer drills has to produce the same

push forces as the user (up to 300N) under sufficient static deflection of the model’s masses. It does not necessarily

have to have adjustable parameters for grip force and postures. Further investigations have to figure out, if this finding

is also valid for the validation of other product functions like power consumption or power tools’ life expectancy.

References

1. Matthiesen, S., Schäfer, T., Mangold, S. (2012): Modelling and Simulation of the Hand-Arm-System during

Impact Influences. ASME International Mechanical Engineering Congress and Exposition, Volume 2:

Biomedical and Biotechnology: 909-918.

2. Marcotte, P., Boutin, J., Jasinski, J. (2010): Development of a hand–arm mechanical analogue for evaluating

chipping hammer vibration emission values. J. of Sound and Vibration 329, Issue 10: 55-82

3. Dong, R. G., Welcome, D. E., Wu, J. Z., McDowell, T. W. (2008): Development of hand-arm system models for

vibrating tool analysis and test rig construction. Noise Control Engineering Journal 56(1): 35–44.

Page 77: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

77

A METHOD TO DEVELOP HAND-ARM MODELS FOR SINGLE IMPULSE STIMULATION

*Sven Matthiesen, Sebastian Mangold, Tobias Schäfer, Sebastian Schmidt

IPEK – Institute of Product Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany

Introduction

The aim of this paper is to describe a method of calibrating a durable and test-rig-suitable hand-arm model

that is valid for simulating the responses of the hand-arm system to high impulsive accelerations.

Developing or optimizing power tools, is nearly impossible without considering the interdependencies

between human, tool and application. Therefore, the super system (user, power tool and application) must be

considered as a holistic system. In validation tasks within the product development process, the impossibility of

dividing this system leads to many uncertainties. Through the intensive interaction between the user and the power

tool, there is a significant impact on the life expectancy and functionality of the power tool. Therefore, the researchers

aim is to develop mechanical analogous systems to describe the mechanical influence of the hand-arm system on

power tools. By implementing those models into test rigs, most researchers pursue the approach of low-complexity,

linear, and lumped-parameter models1. Biomechanically motivated models that investigate internal forces or vibration

transmission within the hand-arm-system and have a higher model complexity do not have the necessary durability

for test rig application1. Despite an abundance of investigations that model the human response on vibrating power

tools, only a few investigations focus on high deflecting single impulses. In the case of such impulses, according to

Griffin2, the user performs a shock motion, because it is a deterministic, non-periodic movement. A method to analyze

such shock motion will be presented in this paper. Additionally, the method will be demonstrated by the development

of an example model that describes those interactions between a power tool and the user.

Methods

In principle, there are three methods that investigate the human response to motion stimulations (mechanical

impedance) caused by power tools. Figure 1 illustrates these methods: (1) Use of a stimulation system (e.g. shaker

systems) with a measurement handle to not only stimulate the hand-arm-system but also measure the force and

deflection at the handle bar. (2) Manipulation of a power tool’s handle to measure force and deflection in real

applications. (3) Creation of a model of the overall system (tool, hand-arm-system and application) to simulate the

force and deflection. The aim of this study is to describe a method to parameterize a durable and test-rig-suitable hand-

arm model that is valid for high deflections and very high accelerations. The method of using a shaker as a substitute

system (1) to investigate the driving point impedance of the hand-arm-system, is widely described for vibrations (e.g.

Dong3). Unfortunately nowadays there are no stimulation systems

available with high deflections and very high accelerations to

stimulate realistic impulses. By manipulating the power tool’s

handle (2) there is a risk of unknown influences caused by the

implementation of the sensors (mass, stiffness). Such manipulated

handles are described in a few studies, but not in case of high

impulsive power tools. This paper presents an example for method

(3) – An investigation of the human response on motion stimulations

by using a theoretical overall model for power tool and user

interaction. With this approach neither a substitute stimulation

system nor an integrated force measurement system in the power

tool handle is needed. The method is based on the idea that any kind of user interaction at the power tool handle will

directly lead to an influence of the power tool’s behavior. Figure 2 illustrates this innovative method. At first,, a model

without user influence is used to predict the power tool’s behavior under well-known conditions. Second, the

interaction between the subsystems user and power tool is visually analyzed with a high-speed camera system to obtain

hints of how the model needs to be structured (e.g. movements in only one direction). Third, the model of the power

tool’s behavior without user influence (model-based to eliminate the well-known influence) has to be combined with

the user’s structure model of the second step. In this third step, the parameters of the user’s structure model have to

be iterated, until the behavior of the power tool in the overall system’s simulation matches the observed power tool’s

behavior in real application.

To demonstrate this method a highly accelerating power tool, a direct fastening device (i.e., bolt setting

device and a powder actuated nail gun) is used as a sample in this study. These power tools are usually used in

Fig. 1: methods to develop a hand-arm model

Page 78: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

78

construction and manufacturing to fix sheet metal parts onto steel or concrete. Caused by a pyrotechnical combustion

of a powder cartridge, the tool accelerates up to 3600 m/s² in one single shock. Within the first step, the power tool is

simplified to a spring-mass-damper system. This model describes the masses’ movements while setting nails without

the user’s influence. To identify the internal tool characteristic, the power tool safety features are manipulated so that

it is possible to actuate it without any user interaction. By comparing the measured and simulated masses’ movement

(velocity), the spring value, damping value and the motion force (Fcartridge - responsible for power tools movement) are

calculated in MATLAB Simulink®. Without user interaction, the force (Fpressing down) is zero and the masses (m1 & m2)

do not exist. The power tool loses contact to the ground right after combustion. Therefore, no forces are induced into

the power tool from application. Thus, an application or nailing model is not needed. Within the second step, the

interactions between a user and the power tool has been visually analyzed with a high-speed camera. It has been

observed that the power tool’s movement is mostly in one direction. Additionally, it has been observed that at first,

the user’s ball of the thumb is compressed completely, and afterwards, the hand starts to accelerate. As a result, a one

dimensional linear spring-damping system with graded stiffness and damping rate, as shown in figure 2, is needed to

simulate the interactions between a user and the power tool. After building a power tool model (step 1) and a structure

model of the user (step 2), the whole system can be built up in MATLAB Simulink® through the combination of the

two sub-models in the third step. The masses, spring value, and damping value of the defined user’s structure model

of the second step can be found through the comparison of the masses’ movement (velocity) of the power tool in this

overall system simulation and those measured in real application with the user.

Fig. 2: The three steps to develop a hand-arm model for a direct fastening device

Results

With the presented method, it is possible to parameterize a durable and test-rig-suitable hand-arm model that

is valid for simulating responses to high acceleration caused by impulses. Furthermore, it has been shown that the

user-power tool interaction, in case of impulsive movements, can be modeled as a linear lumped-parameters model.

The parameters of this user replacement model were determined to develop a test rig for power tools. Despite

differences in users’ statures, it is possible to simulate different repercussions by only varying the model masses. The

parameters of the spring-damping-system can be left unchanged. The parameter of the second mass (m2) differs by

0.4 kg, and the parameter of the first mass (m1) differs by 0.5 kg in two exemplary users using a constant contact

pressing force of 20 N.

References

1. Rakheja, S., Wu, J. Z., Dong, R. G., Schopper, A. W. (2002). A comparison of biodynamic models of the human

hand-arm system for applications to hand-held power tools. J. of Sound and Vibration 249(1): 55-82

2. Griffin, M. J. (1990). Handbook of human vibration. London: Academic Press.

3. Dong, R. G., Welcome D. E., Xueyan, X. S., Warren, C., McDowell, T. W., Wu, J. Z. (2012). Modeling of the

biodynamic responses distributed at the fingers and palm of the hand in three orthogonal directions, J. of Sound

and Vibration 332(4): 1125-1140.

Page 79: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

79

A METHOD TO DESIGN A HAND-ARM MODEL WITH TRANSLATIONAL AND ROTATIONAL

DEGREES OF FREEDOM FOR HIGH ACCELERATED APPLICATIONS

- A CASE STUDY WITH HAND HELD POWER TOOLS -

Sven Matthiesen , *René Germann , Sebastian Mangold

IPEK – Institute of Product Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany

Introduction

This paper addresses the problem of describing the human hand-arm-system accelerated by high impact

forces in two directions. For this purpose, a method for describing the dynamic behavior of the hand-arm-system in

one direction was extended in this study.

Highly accelerated power tools, such as bolt setting devices, are influenced by very high loads during their

use. Because the loads are partially from the intensive interaction between a user and the power tools, the life

expectancy and functionality of the power tool may significantly depend on that interaction. Therefore, an accurate

description of the influence caused by the user on power tools is very important in the product design process. One

possibility to describe the interactions between the user and a power tool is the use of the mechanical impedance1. In

order to measure this, the force between the user and the power tool and the velocity at the handle have to be measured

with accelerometers and force sensors. Analyzing highly accelerated power tools with these modifications leads to

strong measuring inaccuracies due to the sensor apparent masses. Therefore, in case of highly accelerated power tools,

it is necessary to use a method that modifies the masses as little as possible. Describing the discovered interactions

between the user and the power tool can be done with a physical hand-arm-model which consists of rigid bodies

connected to spring and damper elements. With such models, it becomes possible to design a test rig which interacts

like a hand-arm-system with the tool and analyze the behavior of highly accelerated power tools under realistic,

reproductive conditions. This paper presents an approach to identify the structure and the relevant parameters of such

a model.

Methods

To develop a well-working test rig for highly accelerating power tools, it is necessary to define some

boundary conditions that keep the development of the hand-arm-model into defined limits. These boundary conditions

imply, for the transformation of the hand-arm-model into a test rig, a design with as little complexity as possible,

realistic weights and a realistic response2. Matthiesen et

al.3 developed a method that enables analyzing highly

accelerated power tools with very little modifications.

The method is based on the theory that any user

influence will lead to specific movement of the power

tool’s masses. Furthermore, Matthiesen et al.3 has

shown that the influence of the user can be measured

through the comparison of the tool actuated with or

without the user. Therefore, the movements of the

masses in these two cases have to be measured, and the

difference can be evaluated. The difference in

movement is equal to the forces applied by the user.

However, Matthiesen et al.3 presented this method (Figure 1) only for translational movement of highly accelerated

power tools in their main direction. Many power tools do have an additional rotational or translational movement,

which leads to the need of hand-arm models valid for planar motion. Therefore, the method gets extended in this paper

by analyzing the movement of a direct fastening device’s masses in the translational and rotational directions. Based

on the method shown in figure 1, it is necessary to analyze the movements of the power tool’s masses without a user’s

influence. This can be achieved by little modifications in the tool so that it can be actuated without any user influence.

During the experiment, the movements of the power tool’s masses are filmed by a high-speed camera system. Making

use of tracking software, which is able to track the global and inner displacement of the device during the test case, it

is possible to describe the movement of both the handle and the whole power tool. Those movements can be described

in a rigid body simulation model. The model therefore has been implemented in Matlab Simulink® - valid for free

movements in plane – and has been iterated as long as simulated masses movements fit the measured ones. To describe

the behavior of the power tool with the influence of the user, the experiment is repeated with the modified power tool

Figure 1: Method for analyzing the influence of the user

with high accelerated power tools

Simulation model of the complete system power tool with user interaction

Simulation model of the power

tool

Analyzing the power tool

without the user

Analyzing the power tool with the user

Page 80: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

80

but this time, it is operated by the user and analyzed by the high speed camera system again afterwards. According to

the method shown in figure 1, the influence of the user is now equal to the difference between the measured data with

the user and the simulated data of the power tool’s model. A hand-arm-model, which has an equivalent output as the

hand-arm-system, has to influence the masses’ movements of the simulated power tool in a way that is equivalent to

the measured data of the power tool with the user. Under consideration of the boundary conditions, it is possible to

design a hand-arm-model that consists of rigid bodies, translational and rotational connectors, and several spring and

damper elements.

Results and Discussions

The developed model of the hand-arm-systems is displayed in figure 2. It consists of three masses connected

by springs and dampers. The translational spring / damper system cGH / dGH is responsible for a delayed force

transmission from the power tool to the rest of the model, which is equivalent to the realistic response of the power

tool. The connection between this spring/damper system and mass m1H has a rotational degree of freedom. The masses

m1H, m2H and m3H are connected together with a spring-mounted and damped rotational degree of freedom by the

constants cHA / dHA. The connection to the model ground is implemented with the spring / damper system cAD / dAD.

In combination with the power tool’s model, a simulation model of the complete system power tool and user model

can be created. Once more, this overall model has been iterated until simulated movements of the power tool masses

fit the measured ones.

Figure 2: Rigid body simulation modell of the

hand-arm-system

Figure 3: Measured and simulated velocity for one user –

above: main setting direction , below: offset direction

The designed model meets the requested boundary conditions of a simple rigid body model and is able to

accurately simulate the influence of one specific user on a power tool. The presented method is able to define an

explicit structure and the fitting parameters for a model of a highly accelerated hand-arm-system. Figure 3 displays

the simulation results of the main setting and the offset direction in comparison to the measured data. A distinctive

feature of the model is the universal adaptability to different users. By adjusting the parameters of the model, it is

possible to simulate the system with one fixed structure for different users. Afterwards, the simulation model can be

transferred into a test rig. When analyzing more complex applications, further investigations are required to explore

the three-dimensional simulations of these applications. It will also be challenging to create a biomechanically-

motivated hand-arm-model that is suitable for simulating different hand-arm postures.

References

1. Suggs, C. W., Abrams, C. F. (1971): Mechanical impedance techniques for evaluating the dynamic characteristics

of biological materials. Journal of Agricultural Engineering Research 16 (3): 307–315.

2. Dong, R. G., Welcome, D. E., Wu, J. Z., McDowell, T. W. (2008): Development of hand-arm system models for

vibrating tool analysis and test rig construction. Noise Control Engineering Journal 56 (1): 35–44.

3. Matthiesen, S., Schäfer, T., Mangold, S. (2012): Modelling and Simulation of the Hand-Arm-System during

Impact Influences. ASME International Mechanical Engineering Congress and Exposition, Volume 2:

Biomedical and Biotechnology: 909–918.

0 0.005 0.01 0.015 0.02 0.025 0.03-1

-0.5

0

0.5

1

time in s

velo

city in

m/s

measured

simulated

0 0.005 0.01 0.015 0.02 0.025 0.03-2

-1

0

1

2

time in s

velo

city in

m/s

measured

simulated

Offset direction

Main setting

direction

Page 81: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

81

Session VII: Combined Exposures and Health Effects

Chair: Ron House and Danny Riley

Presenter Title and authors Page

Tammy Eger Keynote 2: Understanding the link between occupational

exposure to foot-transmitted vibration and the

development of vibration induced white-feet

*Tammy Eger Mallorie Leduc, Katie Goggins, Aaron

Thompson, and Ron House

82

Enrico Marchetti Combined effect of noise and hand-arm vibration

exposures on the cochlear function

Tirabasso A., Botti T., Lunghi A., Di Giovanni R., Sacco

F., Marchetti E., Cerini L., Sanjust F. , Moleti A., Sisto R.

84

Alice Turcot The challenging diagnosis and management of thoracic

outlet syndrome in HAVS syndrome

Alice Turcot and Jessica Ruel-Laliberté

86

Enrico Marchetti Muscular sync and hand-arm fatigue

L. Fattorini, A. Tirabasso, A. Lunghi, R. Di Giovanni, F.

Sacco, E. Marchetti

88

Page 82: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

82

UNDERSTANDING THE LINK BETWEEN OCCUPATIONAL EXPOSURE TO

FOOT-TRANSMITTED VIBRATION AND THE DEVELOPMENT OF

VIBRATION-INDUCED WHITE-FEET

*Tammy Eger+,++ Mallorie Leduc+, Katie Goggins+,

Aaron Thompson+++,++++, and Ron House+++,++++

+Centre for Research in Occupational Safety and Health, Laurentian University, Sudbury ON, Canada ++School of Human Kinetics, Laurentian University, Sudbury, ON, Canada

+++Department of Medicine, Division of Occupational Medicine, University of Toronto, Toronto, ON, Canada ++++Department of Occupational and Environmental Health, St. Michael’s Hospital, Toronto, ON, Canada

Introduction

Workers in a number of industries are exposed to vibration that is transmitted into their

bodies through the feet. For example, jumbo drill operators in mining, crusher operators in

construction, and all-terrain-vehicle drivers in agriculture are commonly exposed to foot-

transmitted vibration (FTV). This paper will review current knowledge regarding the development

of vibration-induced white-feet (VWFt) by examining clinical evidence and findings from field

and laboratory studies investigating FTV.

Findings from Clinical Studies

Recent evidence suggests workers exposed to FTV can develop a medical condition

analogous to hand-arm vibration syndrome (HAVS). A worker with VWFt may present with

numbness and tingling in their toes/feet, and cold induced blanching in their toes1. However, data

on VWFt are limited as previous research suggested workers who had vascular problems in the

feet were likely experiencing symptoms secondary to vascular damage associated with exposure

to hand-arm vibration2. Two cases offer evidence which supports the development of VWFt

independent of exposure to hand-arm vibration1,3. In one case, a mink farmer exposed to FTV from

contact with the pedal of an agricultural tractor developed cold-induced blanching in his foot3 and

in the second case a miner with exposure to FTV from operating a bolter was diagnosed with

VWFt1. Neither worker had symptoms compatible with HAVS.

Findings from Field Studies

Field measures documenting the characteristics of occupational exposure to FTV are

limited and have emerged primarily from the mining industry with researchers reporting FTV

exposure associated with the operation of locomotives, bolters, jumbo drills, raise platforms, pit

drill/platforms, cavo loaders, scissor lifts, and crushers4-7. ISO 2631-1 frequency weighted r.m.s

acceleration magnitudes reported (vertical axis) range from a high of 2.62 m/s2 for the Cavo

loader8, to 0.84 m/s2 when drilling off a raise platform5, to 0.76 m/s2 when driving a locomotive6,

to 0.45 m/s2 when operating a bolter6, and to a low of 0.22 m/s2 when standing on a crusher

platform5. However, it might be more relevant to consider vibration exposure frequency, and not

just magnitude, when determining injury risk. When miners were asked to report symptoms of

pain/ache/discomfort in the feet 33% of the surveyed locomotive operators (exposed to FTV with

a vertical axis dominant frequency below 5Hz) reported symptoms while 75% of the raise

operators (exposed to vertical axis FTV with a 40 Hz dominant frequency) reported symptoms5.

Furthermore, in a study of 27 miners six had symptoms of VWFt and all six drilled off a raise

Page 83: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

83

platform (40 Hz dominant frequency)7. In 2011 Leduc and colleagues4 reported miners exposed to

FTV with a vertical axis dominant frequency of 31.5 Hz (Jumbo Driller) and 40 Hz (raise platform

driller) had symptoms of VWFt and the bolter operator described in the case study by Thompson

et al., 2010 was also exposed to FTV (40Hz dominant frequency)1. Although not conclusive as

some of the operators in the Leduc study also had a history of hand-arm vibration exposure, these

data suggest workers exposed to FTV in the 30-40Hz range could be at an increased risk of

developing VWFt.

Findings from Laboratory Transmissibility Studies

In a recent laboratory study9 vibration transmissibility was measured from the floor

(vibration platform surface) to the top of the greater toe (first metatarsal) and the floor to the ankle

(medial malleolus) for FTV with a dominant frequency of 25, 30, 35, 40, 45, and 50 Hz. Floor to

ankle transmissibility magnitude was greatest at 30Hz and floor to toe transmissibility magnitude

was greatest at 50Hz. Harazin and Grzesik10 evaluated vibration transmissibility from the floor to

the metatarsus, ankle, knee, hip shoulder and head at frequencies ranging from 4–250 Hz in 1/3

octave bands. They found the magnitude of vibration transmitted by the foot was amplified in the

frequency range of 31.5-125Hz at the metatarsus and 25-63Hz at the ankle.

Summary and Future Research

This review offers evidence from clinical, field and laboratory studies that suggest workers

exposed to FTV are at risk of developing VWFt. Moreover, injury risk appears to be greater in

workers exposed to FTV in the 30-40 Hz range. Further research is required to characterize

resonant frequencies for different regions of the toes, foot and lower limb with an aim to develop

exposure guidelines for workers and controls to protect workers from exposure to FTV frequencies

and magnitudes associated with injury development.

References

1. Thompson, A., House, R., Krajnak, K., and Eger, T. (2010). Vibration-white foot: a case report. Occupational

Medicine, 60, 572-574.

2. House, R., Jiang, D., Thompson, A., Eger, T., Krajnak, K., Sauve, J., and Schweigert, M. (2011). Vasospasm in

the feet in workers assessed for HAVS. Occupational Medicine, 61, 115-120.

3. Tingsgard I, Rasmussen K. (1994). Vibration-induced white toes. Ugeskr Laeger. 156, 4836-4838

4. Leduc, M., Eger, T., Godwin, A., Dickey, J.P., and House, R. (2011). Examination of vibration characteristics

and reported musculoskeletal discomfort in workers exposed to vibration via the feet. Journal of Low Frequency

Noise, Vibration and Active Control. Vol 30(3), 197-206.

5. Eger, T., Thompson, A., Leduc, M., Krajnak, K., Goggins, K., Godwin, A., and House, R. (2014) Vibration

induced white-feet: Overview and field study of vibration exposure and reported symptoms in workers. WORK:

A Journal of Prevention, Assessment & Rehabilitation 47(1): 101-110

6. Eger, T., Salmoni, A., Cann, A., and Jack, R. (2006). Whole-body vibration exposure experienced by mining

equipment operators. Occupational Ergonomics, 6(3/4), 121-127.

7. Hedlund, U. (1989). Raynaud’s Phenonmenon of fingers and toes of miners exposed to local and whole-body

vibration and cold. International Archives of Occupational and Environmental Health, 61, 457-461.

8. Ouellette, S., and Marcotte, P. (2010). Mine workers exposure to noise and vibrations. Report for SOREDEM

(CANMET-MMSL 10-010(J).

9. Goggins, K., Godwin, A., Boudreau-Lariviere, C., and Eger, T. (2014). Examination of vibration

transmissibility from floor to metatarsal and floor to ankle between 25 and 50hz. 5th American Conference on

Human Vibration, Guelph, ON, June 10-13.

10. Harazin, B. & Grzesik, J. (1998). The transmission of vertical whole-body vibration to the body segments of

standing subjects. Journal of Sound and Vibration, 215(4), 775-787.

Page 84: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

84

COMBINED EFFECT OF NOISE AND HAND-ARM VIBRATION EXPOSURES

ON THE COCHLEAR FUNCTION

A. Tirabasso+, T. Botti+, A. Lunghi+, R. Di Giovanni+, F. Sacco+, *E. Marchetti+,++, L. Cerini+,

F. Sanjust +, A. Moleti+++, R. Sisto

+INAIL Research, Department of Occupational and Environmental Medicine, Epidemiology and Hygiene

++Sapienza University of Roma, Department of Physiology and Pharmacology “V. Erspamer” +++University of Roma Tor Vergata, Department of Physics, Rome, Italy

Corresponding author: [email protected]

Introduction

Epidemiological studies1,2 and animal3 experiments pointed out a synergistic interaction of

mechanical vibration and noise exposure in inducing hearing impairment4. From the

epidemiological point of view, the evidence of this synergistic effect is quite well assessed;

however, there is still uncertainty of the mechanistic explanation of this phenomenon.

Until now, experiments on human subjects have been performed using audiometry as the

unique test for hearing status assessment. The audiometric test suffers from some limitations,

because it is based on the active collaboration of the subject. Recently, a more objective technique

has been proposed that is based on biomarkers of the cochlear functionality: the otoacoustic

emissions (OAEs).

The present paper studies the combined HAV and noise effect on human subjects in the

laboratory and makes use of OAEs to assess changes of the cochlear functionality in relation to

the exposure condition.

Methods

OAEs are spontaneous or evoked sounds generated by the inner ear. They propagate back

toward the ear canal where they can be recorded by a sensitive microphone. Since OAEs are the

effect (linear and nonlinear) of cochlear activity, they provide information about the cochlear

performance. Twelve normoacusic volunteers were randomly exposed to 1) HAV only, 2) noise

only, and 3) HAV plus noise. Before exposure, all subjects were screened by means of standard

pure tone audiometry and DPOAE (Distortion Product OAE) test with high frequency-resolution.

DPOAEs have been recorded with and without contralateral acoustical stimulation (CAS) of 80

dB SPL in order to assess the exposure effects on the medial olivo-cochlear (MOC) efferent

system. The CAS suppresses the OAE amplitude in normoacusic young non-exposed subjects. In

the condition, 1) each volunteer was exposed on his right side to HAV of 30 m/s2rms acceleration

at 60 Hz for 3 minutes (RMS Shaker plus handle for grip force measuring). The grip force that the

subject was required to sustain was 20% of the maximum voluntary contraction (MVC). During

exposure to HAV, the subject wore ear muffles in order to be insulated from the background noise

produced by the shaker. In the condition 2) the subject was exposed to white noise (0-10 kHz, 95

dBA) by a loudspeaker probe inserted in the right ear canal.

The exposure to noise and HAV was obtained by combining conditions 1) and 2). Each

exposure condition was repeated 5 times, and during exposure intervals, DPOAEs were recorded

Page 85: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

85

in the right ear canal. After the last exposure, DPOAE and audiometric tests were performed.

Finally, DPOAEs were recorded every 10 minutes for half an hour during recovery. A suitable,

time-frequency wavelet analysis has been carried out to separate DPOAE distortion and reflection

components. A paired student’s t test was performed to assess the statistical significance of the

differences in each frequency band.

Results and Discussion

Statistical significance for pre-post audiometry comparison was negative in all conditions.

Statistical significance for pre-post DPOAE amplitude comparison was negative in the case of

condition 2) but positivefor some frequency bands in conditions 1) and 3). The two exposure

conditions, HAV only and combined HAV and noise, gave statistically significant pre-post

differencesin the mid frequencies, particularly at

3605 Hz. The two conditions gave opposite

effects: in the case of HAV only, there was an

increase, while in the case of a combined exposure,

there was a decrease in DPOAE amplitude (see

Fig. 1). After 30 minutes of the last exposure, full

recovery could be observed in all cases. These

results deserve to be investigated with a larger

sample. Moreover, in order to ascertain the

mechanistic interaction of noise and vibration in

inducing effects on the cochlear’s function, it is

important to follow the transmission of HAV from

the entering point to the inner ear.

Figure 1. Differences between post-exposure (exp) or

recovery (rec) and pre-exposure (pre) DPOAE amplitudes

without (A) and with (B) CAS (averaged on 12 subjects and

in the frequency band centered at 3605 Hz) measured in

Vibration (V) and Noise&Vibration (NV) condition. Stars

indicate significant differences between pre- and post-

exposure DPOAE amplitude.

References

1. Pyykkö, I., Starck, J., Färkkilä, M., Hoikkala, M., Korhonen, O. and Nurminen, M. Hand-arm vibration in the

aetiology of hearing loss in lumberjacks, British Journal of Industrial Medicine, 38, 281-289, (1981).

2. Pyykkö, I., Starck, J. and Pekkarinen, J. Further evidence of a relation between noise-induced permanent threshold

shift and vibration-induced digital vasospasm, American Journal of Otolaryngology, 4, 391-398, (1986).

3. Zou, J., Bretlau, P., Pyykkö, I., Starck, J. and Toppila, E. Sensorineural Hearing Loss after Vibration: an Animal

Model for Evaluating Prevention and Treatment of Inner Ear Hearing Loss, Acta Oto-laryngologica, 121, 143-

148, (2001).

4. Zhu S., Sakakibara S., Yamada S. (1997). “Combined effects of hand-arm vibration and noise on temporary

threshold shifts of hearing in healthy subjects,” Int. Arch. Occup. Environ. Health 69, 433-436.

Page 86: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

86

THE CHALLENGING DIAGNOSIS AND MANAGEMENT OF THORACIC OUTLET

SYNDROME IN HAVS SYNDROME

*Alice Turcot, Jessica Ruel-Laliberté

Institut national de santé publique du Québec, Québec, CANADA

Introduction

Thoracic outlet syndrome (TOS) is defined as a group of symptoms that result from the entrapment

of the brachial plexus and/or subclavian vessels in the thoracic outlet region, between the neck and the

axilla. There are 3 types of TOS, depending on which structure is compressed: neurogenic (brachial plexus),

venous (subclavian veins, 4%–5%) and arterial (subclavian artery, 1% of cases). The most common type is

neurogenic which accounts for more than 90% of cases. The neurogenic type can be subdivided into true

neurogenic and disputed neurogenic, depending on whether nerve conduction studies show changes or not,

respectively. The prevalence is also debated and varies with the clinical location where the diagnosis is

made and with the medical specialty of the treating physician. According to Edwards,2 it is estimated at

approximately 10 cases per 100,000 for all of the types. TOS patients present symptoms that may overlap

or mimic hand-arm vibration syndrome (HAVS), such as hand weakness, loss of dexterity, pain,

paresthesia, fatigue or Raynaud’s phenomenon. Furthermore, the differential diagnosis of TOS is extensive,

including cervical radiculopathy, peripheral nerve entrapment, and shoulder pathology. Accurate diagnosis

is difficult due to the absence of clearly defined diagnostic criteria. TOS was described for a group of

workers suffering from white fingers related to hand-arm vibration.

The purpose of this presentation is to review the controversy surrounding the diagnosis and

management of TOS, to review the etiologies with special regard to work-related risk factors and vibrating

tools, and to present the results of an analysis that explores whether workers with a combined diagnosis of

TOS and white fingers have a different clinical presentation than those with only a white finger diagnosis.

Two clinical cases of TOS identified in the database will also be presented.

Methods

We searched OVID SP (EBM Reviews-Cochrane Central Register of Controlled Trials May 2013,

EBM Reviews-Cochrane Database of Systematic Reviews 2005 to April 2013, Ovid MEDLINE(R) 1946

to 2013, Global Health 1973 to 2013) in French and English focusing on TOS, diagnosis, work-related risk

factors, and treatment (review, meta-analysis). A total of 462 articles were retrieved. One database was also

analyzed, by paying particular attention to the clinical presentation, diagnostic tests and functional

limitations. The participants in this study come from a database of people who applied for compensation to

the Commission de la Santé et de la Sécurité du Travail (CSST, Quebec workers’ compensation board)

between 1993 and 2003. Three hundred and forty-three (344) individuals with white fingers were thus

included in the study. From this same database, 42 simultaneously had TOS and white fingers. Their

characteristics were thus compared to the 302 individuals with white fingers only.

Results and Discussions

To date, very few studies have compared the clinical presentation of subjects with a combined

diagnosis of TOS and HAVS to those with only HAVS. TOS has been described as linked to a combination

or not of constitutional factors (cervical rib, etc.) coupled with muscular dysfunction and repetitive trauma.

However, few epidemiological studies on the prevalence or incidence of TOS among workers from different

Page 87: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

87

economic activity sectors or even dealing with the analysis of ergonomic risks related to TOS have been

described. TOS has been described for workers exposed to hand-arm vibration among workers on a

shipyard or construction site)3,4. TOS has been described for symptomatic subjects, namely musicians,

archers, swimmers or for sports requiring a prolonged awkward posture. A diagnosis of TOS and its

treatment remain controversial, and for some, TOS (neurogenic) is a highly overdiagnosed condition and

is treated all too frequently with unnecessary and potentially harmful surgery without an objective, clinical,

radiographic, and electrophysiological basis. There are few randomized studies that compare the surgical

approach to the conservative approach. Many more articles deal with the surgical approach in the treatment

of TOS. However, one notes a consensus that a conservative approach is offered first, followed by the

surgical approach when the conservative treatment fails.5

Analysis of the database reveals that subjects suffering from TOS and white fingers are not different

from workers with white fingers for the type and number of vibrating tools, past exposure to vibration, and

the economic activity sector. Different diagnostic terms are used by clinicians to describe TOS. The TOS

sub-type is not described; it is assumed that it is neurogenic. Fifty-seven percent (57%) of people with

combined TOS present one of the clinical tests for positive thoracic outlet compared to 18.5% of those with

white fingers (OR=5.16; CI (95%): 2.45-10.89; p-value < 0.001, adjusted for years of exposure to

vibration). Although, the information is not available for 124 workers with white fingers only. The TOS

diagnosis is not retained consensually in all of the cases. The clinical presentation of the two groups is

comparable, in terms of presence of white fingers, functional limitations and the anatomopathological

deficits assigned. Also, specific recommendations regarding the functional limitations related to TOS are

not given. Eighty-one percent (88.1%) of people with combined TOS present numbness compared to 76.6%

of the people with white fingers alone (OR=3.42; CI (95%): 1.01-11.57; p-value =0.048, adjusted for years

of exposure to vibration). Carpal tunnel syndrome is described in 22.0% of workers with TOS compared to

23.6 % of workers with white fingers (OR=0.87; CI (95%): 0.38-2.01; p-value=0.748 adjusted for years of

exposure). Little surgery is offered to subjects with TOS.

Considering the nature of the study, research should be pursued before concluding that there are

differences in the clinical presentations. The work-related etiological factors of TOS are not studied

systematically, but should be. Carpal tunnel syndrome present in HAVS could be secondary to the presence

of compression higher up, as described in double crush syndrome, but further studies are needed. TOS

diagnosis should therefore be systematized in a medical protocol, and a consensual definition of the disease

is necessary. There is a need to describe the prevalence of the disease in workers in order to understand the

role of ergonomic stressors and vibration, and thus produce appropriate recommendations for treatment.

References

1. Klaassen, Z., Sorenson, E., Tubbs, R.S., Arva, R., Meloy, P., Shirk, S., and Loukas, M. (2014). Thoracic outlet

syndrome: a neurological and vascular disorder. Clinical Anatomy 27(5): 724-732.

2. Edwards, D., Mulkern, E., Raja, A., and Barker, P. (1999). Trans-axillary first rib excision for thoracic outlet

syndrome. Journal of the Royal College of Surgeons of Edinburgh 44(6): 362-365.

3. Letz, R., Cherniack, M.G., Gerr, F., Hershman, D., and Pace, P. (1992). A cross sectional epidemiological survey

of shipyard workers exposed to hand-arm vibration. British Journal of Industrial Medicine 49(1): 53-62.

4. Hagberg, M. (2002). Clinical assessment of musculoskeletal disorders in workers exposed to hand-arm vibration.

International archives of occupational and environmental health 75: 97-105.

5. Povlsen, B., Belzberg, A., Hansson, T., and Dorsi, M. (2010). Treatment for thoracic outlet syndrome (Review).

Cochrane Database of Systematic Reviews. Published in The Cochrane Library Issue 1.

Page 88: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

88

MUSCULAR SYNC AND HAND-ARM FATIGUE

L. Fattorini+, A. Tirabasso++, A. Lunghi++, R. Di Giovanni++, F. Sacco++, *Enrico Marchetti+,++

+Sapienza Università di Roma, Department of Physiology and Pharmacology “V. Erspamer”, Rome, Italy ++National Institute for Insurance against Accidents at Work

Department of medicine, epidemiology, workplace and environmental hygiene, Rome, Italy

Introduction

Muscular fatigue is a topic that deserves greater attention in a world that has made an even greater

use of vibrating tools. Since, 1997, when Martin and Park1 introduced a measuring parameter of muscular

synchronization with the external mechanical vibration frequency, there have been few developments on

the consequences of this synchronization. The presence of an external, mechanical, and rhythmic stimulus

induces a coherent activation of most muscular fibers (e.g., motor unit synchronization) which may impair

the physiological muscular activation while performing the motor task. The Sync level (SL) is defined as

the spectral power density integrated around the mechanical vibration frequency and then divided by the

integral of the whole spectral density. The present work is aimed to both assess the relationship between

SL and fatigue and reproduce the standard experimental conditions similar to those met in field.

Methods

The experiment consisted of exposing the hand-arm system (HAS) to vibration at various

frequencies and grip forces, and comparing the assessed parameters without mechanical vibration (MV).

Sixteen subjects, 9 females and 7 males, participated in the experimental study. MV on the handle was

elicited by an electrodynamic shaker (RMS SW 1508, Germany, EU) driven by a controller (Vibration

Research VR 7500-2, Germany, EU) at 20, 30, 33 and 40 Hz. The signal had a constant velocity of 27

mm/s. In order to take into account interpersonal differences, the exerted grip force(GF) was expressed in

terms of Maximum Voluntary Contraction (MVC). In the motor task, the participant maintained a grip force

of20, 30, 40, and 60 % MVC on the dominant hand for 45 seconds. The posture was standardized in

accordance with the UNI EN ISO 10819 (1998) for glove testing. Muscular activity has been assessed by

surface electromyography (sEMG) of extensor carpi radialis longus (ECRL) muscles. The sEMG was

acquired by the wireless system Zero Wire (Cometa, Italy, EU). Additionally, EMG signals were

transmitted and recorded on the digital analyzer OROS OR38 (Oros, France, EU). Furthermore, data

analysis was performed off-line with ad hoc applications developed with MatLab Release 2008a

(Mathworks, Massachusetts, USA). As reported by Martin1, the SL index was computed at the specific

vibration frequency at the beginning and at the end of the measurement. In this study, delta SL (∆SL) was

defined as a percentage difference of the early exposure (first 3 seconds of steady state of grip force) and

the late exposure (last 3 seconds of exposure). Median frequency decay (MDFd) was evaluated in EMG

windows of 1 second, from which a linear regression was calculated. The MDFd being accountable of the

long term muscular fatiguing response to vibration2 and presents negative values.

Results and Discussions

Studying the ∆SL results, see Fig. 1, while it is evident that a clear relationshipexists at 20, 30, 33

Hz of vibration, this relationship disappear at 40 Hz. Interestingly, only at 20% of MVCshowed an increase

of ∆SL with SV augment. The max value is reached at the max force level and a SV of 30 Hz. When

comparing ∆SL with MDFd (Fig. 2), it is possible to catch a parallel: both parameters have an increase in

frequencies and force. While the SL represents the tendency of muscular fibres to synchronize to the

external vibration frequency, the MDFd is thought to be an indicator of muscular fatigue2.

Page 89: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

89

Figure 1: the ∆SL related to vibration frequencies expressed in terms of grip force (% of MVC).

Figure 2: MDFd for the extensor muscle for various frequency and grip force (% of MVC)

In conclusion, it is possible to point out that during long-lasting grip tasks and mechanical vibration

exposure, the muscular fatigue is driven, apart from other factors, by the synchronization of muscular fibres

on the mechanical vibration frequency. Vibration exposures at 30 and 33 Hz seem to be more fatiguing than

others, especially at higher force levels. It is well known that in the range around 30-33 Hz,one of the HAS

resonances3 is present. This resonance mechanic phenomenon has been revealed here by

electromyographical data.

References

1. Martin BJ, Park HS. “Analysis of the tonic vibration reflex: influence of vibration variables on motor

unit synchronization and fatigue”, European Journal of Applied Physiology, 1997;75(6):504–11.

2. De Luca, CJ, “Myoelectric manifestation of localized muscular fatigue in humans”, Crit Rev Biomed

Eng. 1984;11(4):251-79.

3. Marchetti E, Lunghi A, Fattorini L, Nataletti P, Morgia F. Difference between men and women in hand-

trasmitted vibration power absorption.2007, 11th International conference on HandArmVibration,

Bologna

0

20

40

60

80

100

20hz 30hz 33hz 40Hz

De

lta

SL (

%)

SV (Hz)

20%

30%

40%

60%

-0.6

-0.5

-0.4

-0.3

-0.2

-0.1

0

0 20 30 33 40

MD

F d[H

z/se

c]

SV [Hz]

GF20

GF30

GF40

GF60

Page 90: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

90

Session VIII: Risk Assessment and Epidemiology

Chairs: Lihua He and Marco Tarabini

Presenter Title and authors Page

Paul Pitts Evaluation of risk for vascular hand-arm vibration injury

– development of a new ISO technical report

Paul Pitts and Anthony Brammer

91

Frank Bochmann Risk assessment of musculoskeletal disorders among

workers exposed to hand-arm-vibration: design, exposure

assessment methods and first results of an

epidemiological case-control study

Frank Bochmann, Uwe Kaulbars, Winfried Eckert, Yi

Sun

93

Per Vihlborg Vibration survey of workers in Swedish mechanical

industry

Per Vihlborg, Ing-Liss Bryngelsson, Lars-Gunnar

Gunnarsson, Pål Graff, Bernt Lindgren

95

Jacek Kuczyński Improved methods of assessment of vibration risk

Jacek Kuczyński

97

Xiangrong Xu A survey on occupational hazards of coal workers using

hand-transmitted vibrating tools in a northern china coal

mine

Xiangrong Xu, Manman Gong, Zhiwei Yuan, Rugang

Wang, Sheng Wang, Lihua He

99

Page 91: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

91

EVALUATION OF RISK FOR VASCULAR HAND-ARM VIBRATION INJURY –

DEVELOPMENT OF A NEW ISO TECHNICAL REPORT

*Paul Pitts+, Anthony Brammer++

+Health and Safety Executive (HSE), Harpur Hill, Buxton, UK ++Ergonomic Technology Center, University of Connecticut Health, Farmington, CT, U.S.A., and

Envir-O-Health Solutions, Ottawa ON, Canada

Introduction

Since ISO 5349 was first introduced in 1986 (superseded in 2001 by ISO 5349-11), there have been

concerns raised by technical experts that the prediction of incidence of vascular injury from certain machine

types could be improved.2 The standard seemed to over-predict risk from low-frequency machines like sand

rammers, while perhaps over-predicting risk from machines generating large amounts of high-frequency

energy, such as chipping hammers. In order to address these concerns, the ISO hand-arm vibration Working

Group agreed to consider the options for an alternative frequency weighting for vascular hand-arm vibration

injury and have now produced a new method for evaluation in an ISO Technical Report.

This paper reviews the basis for the proposed frequency weighting and the evaluation methodology

provided in a new draft ISO Technical Report: “Mechanical Vibration — Measurement and evaluation of

human exposure to hand-transmitted vibration — Supplementary method for assessing risk of vascular

injury”.

Justification for new frequency weighting for vascular injury

In 2008 the ISO working group on hand-arm vibration (ISO TC 108 SC 4 WG 3) began work to

define a new frequency weighting for vascular hand-arm vibration injury. A set of candidate weightings

were proposed and publicised3 in order to encourage research into the suitability and limitations of the

different weightings:

• Wh-bl: The band-limiting component of the existing frequency weighting,1 Wh

• W hT: A weighting based on epidemiological data of VWF incidence4

• Whf: A weighting based on finger vibration power absorption5

Investigation of these candidate weightings showed that the differences between WhT and Whf

weighted levels is very small across a cross-section of tool types.3 Assessment of the weightings with injury

showed no strong link to any individual weighting,6 but analysis of the apparent relative risk from selected

machine types was able to demonstrate the case for a vascular injury weighting, encompassing the

frequency range from 20 to 400 Hz.7

Following this work, and on the recommendation of experts attending a workshop on frequency

weightings for vascular injury at the Twelfth International Conference on Hand-Arm Vibration (Ottawa),

the ISO technical Committee agreed to develop a Technical Report. The purpose of this Technical report

would be to:

• define a evaluation methodology that supplements that given in ISO 5349-1, and

• ensure that additional data is collected in a common format to help to improve knowledge and

understanding of vascular vibration risks.

Frequency Weighting Wp and Daily Exposure Threshold

Figure 1 compares Wp (a band-limiting filter between 20 and 400 Hz) with ISO 5349-1 frequency

weighting, Wh. In order to have potential value as a measure that is distinct from Wh, acceleration values

assessed with the Wp weighting should not be strongly correlated with equivalent Wh weighted values.

Figure 2 compares average Wh and Wp weighted acceleration values for 39 tool categories across a range of

Page 92: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

92

industries. Analysis shows a statistically significant moderate (Pearson’s r value 0.65) positive correlation

between the two data sets.

Figure 8 Wp and Wh weightings

Figure 9 Comparison of average Wp and Wh weighted

values for a number of different tool categories

To distinguish exposures using Wp from those based on Wh, it is recommended that daily exposure

be assessed as a daily exposure value Ep,d, rather than as an A(8) value. The analysis of Brammer and Pitts

permits an estimate to be made of the smallest daily vibration exposure at which vascular symptoms may

be expected to occur.7 The threshold for the onset and continuing development of white fingers appears to

be in the range: Ep,d = 1150 - 1750 ms-1.5.

It is intended that the new Technical Report be limited to research on vascular hand-arm vibration

injury. It should not be used in place of ISO 5349-1 and data derived from it should not be used instead of

ISO 5349-1 data for fulfilling duties under national regulation, guidance or recommendations for either

workplace vibration exposures or machinery vibration emissions.

Acknowledgements

This publication and the work it describes were in funded by the National Institute for Occupational Safety

and Health under research grant 5R01 OH008997 and the Health and Safety Executive (HSE). Its contents,

including any opinions and/or conclusions expressed, are those of the authors alone and do not necessarily

reflect HSE policy.

References

1. ISO 5349-1 (2001): Mechanical Vibration and Shock – Evaluation of human exposure to hand-transmitted

vibration – Part 1 General requirements, International Organization for Standardization, Geneva, Switzerland.

2. Griffin, M.J., Bovenzi, M., and Nelson, C.M. (2003). Dose-response patterns for vibration-induced white finger,

Occupational & Environmental Medicine, 60, 16-26.

3. Pitts, P.M. (2010). Evaluation of candidates for additional frequency weightings for hand-arm vibration

measurements. VDI-Berichte, 2097, 125-136.

4. Tominaga, Y. (2005). New frequency Weighting of Hand-Arm Vibration. Industrial Health, 43, 509-515.

5. Dong, R.G., Welcome, D.E., McDowell, T.W., Xu, X.S., Krajnak, K., and Wu, J.Z. (2012). A proposed theory

on biodynamic frequency weighting for hand-transmitted vibration exposure, Industrial Health 50(5), 412-424.

6. Pitts, P.M., Mason, H.J., Poole K.A., and Young, C.E. (2011). Relative performance of frequency weighting Wh

and candidates for alternative frequency weightings when used to predict the occurrence of hand-arm vibration

induced injuries. Canadian Acoustics, 39(2), 96-97.

7. Brammer, A.J., and Pitts, P.M. (2012). Frequency weighting for vibration-induced white finger compatible with

exposure-response models. Industrial Health, 50(5), 397-411.

Page 93: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

93

RISK ASSESSMENT OF MUSCULOSKELETAL DISORDERS AMONG WORKERS

EXPOSED TO HAND-ARM-VIBRATION: DESIGN, EXPOSURE ASSESSMENT

METHODS AND FIRST RESULTS OF AN EPIDEMIOLOGICAL CASE-CONTROL

STUDY

*Frank Bochmann+, Uwe Kaulbars+, Winfried Eckert++, Yi Sun+

+ IFA-Institute for Occupational Safety and Health of German Social Accident Insurrance

Sankt Augustin, Germany ++BG-Bau – Berufsgenossenschaft der Bauwirtschaft, Böblingen, Germany

Introduction

Mechanical vibration arises from a wide variety of processes and operations performed in

industry, such as mining, construction and forestry. Studies from different countries indicate an

elevated risk of musculoskeletal disorders among vibration-exposed workers in compare to non-

exposed workers. In Germany, there are approximately 1.5 to 2 million employees are currently

exposed to hand-arm vibration which may represents a threat to their health. Although the human

responses to vibration depend both on the magnitude and frequency of the vibration signal, their

impacts on human health are poorly investigated. In order to quantitatively evaluate the effects of

frequency dependent hand-arm-vibration on the risk of musculoskeletal disorders of the hand-arm-

shoulder system, an epidemiological case-control-study was conducted among workers in the

construction, mining and metal industries in Germany.

Methods

In total, 250 clinical confirmed cases and 750 controls are recruited by the German Social Accident

Insurance Institutions. The individual work history, its related working activities and the use of

hand-transmitted vibration equipment were collected in a standardized personal interview by

trained and experiences work safety inspectors of the German Social Accident Insurance

Institutions. In addition, a database on the magnitude and frequency spectrum of mechanical

vibrations of commonly used hand-transmitted vibration equipment was established based on

standardized industrial hygiene measurements. Information on relevant confounding factors such

as sports, leisure activities and co-morbidities are also collected in the standardized personal

interview.

Page 94: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

94

Results and Discussions

Detailed information on study design, exposure assessment methods, quality control and first

results will be presented.

Page 95: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

95

VIBRATION SURVEY OF WORKERS IN SWEDISH MECHANICAL INDUSTRY

*Per Vihlborg+, Ing-Liss Bryngelsson+, Lars-Gunnar Gunnarsson+,++,

Pål Graff+, Bernt Lindgren+++

+Department of Occupational and Environmental Medicine, Örebro University Hospital,

Sweden ++School of Medicine, Örebro University, Sweden

+++Feelgood Occupational Health Unit Hallsberg, Sweden

Background

Working with handheld vibrating tools is common in the Swedish industry and one of the

main causes of occupational disease. There are well known effects on vascular, neurological and

musculoskeletal symptoms in the hands from vibrations.

Aim

Investigate the frequency of vibration related symptoms in a mechanical industry. The

workers got information about adverse health from vibrations and some also got a medical

intervention, we then did a follow up 3 years after the initial investigation.

Methods

This report is based on examinations performed at an occupational health service of

workers at a company in a mechanical industry unit.

66 out of 68 persons underwent hearing tests and 24 persons also presented symptoms

suggestive of hand-arm vibration syndrome (HAVS). Those 24 persons where offered a medical

examination.

The medical examination consisted of questionnaires regarding symptoms and exposure,

standardized medical examination and in selected cases, quantitative sensory testing (QST)

accomplished at the Department of Occupational and Environmental Medicine, Örebro University

Hospital.

The exposure to vibrations has been measured and estimated below 2,5 m/s2.

Results

Of the total of 23 people that was medical examinated 21 had problem with white fingers,

neurological symtom includning carpaltunnel syndrome. 13 of the 23 person examinated had both

neurlogical symtoms and white finger. Subjects studied were judged to have HAVS. QST was

conducted on the workers with suspected vibration syndrome or other comorbidity and A third of

those surveyed showed signs of carpal tunnel syndrome (CTS)

No significance was found between exposure time, age and place of work. There was no

excess risk for HAVS among those who were snuff users compared to non-users. There was

significant excess risks (OR 23,3 95% CI: 1,12-458) for white fingers for the welders compere to

Page 96: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

96

other workers when data were adjusted for snuff habits and exposure time compere to other

workers.

The follow-up examination three years later showed equal symptom prevalence except on

those with CTS which had improved after surgery. Where 4 patients showed no symptoms after

surgery.

Conclusion

This study shows that HAVS is common in blue collar workers exposed to vibrations even

if the vibration exposure is not very high. Symptoms of HAVS were stationary between surveys

even if the workers were informed of the adverse health effects from vibration exposure. The study

shows the importance to carry out reoccurring medical checks in employment (MKA) to find

people with CTS and other vibration related symptoms to reduce negative impact from work

environment.

Page 97: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

97

IMPROVED METHODS OF ASSESSMENT OF VIBRATION RISK

Jacek Kuczyński

International Marketing Manager, Svantek, Poland

Introduction

Measurement methods described in ISO 5349-1 and

ISO 5349-2 are subject to a high level of uncertainty (±20% to

40%) due to the estimation of daily exposure time. The only

right solution to decrease the level of this uncertainty is the use

of daily vibration exposure meters (DVEM). Similar to noise

dosimeters, daily vibration exposure meters must be small

enough to be worn and must not interfere with normal working

activities. ISO 5349-2 mentions that contact force measurement

should be used to detect when the worker's hands first make

contact with the vibrating surface and when contact is broken.

With the development of the new and very small MEMS

sensors, it became possible to situate the force sensor beside the

vibration accelerometer. This solution allows the user to both

automatically obtain information about the period while the

hand is in contact with the vibrating surface and evaluate the

total contact time per day.

Methods

The study was performed with the SV 103 (Svantek Sp. Z o.o., 2014), SVANTEK’s new

vibration exposure level meter that meets ISO 8041:2005 and was designed to perform

measurements in accordance to ISO 5349-1 and ISO 5349-2 with special adapters mounted on the

operator's hand. The task was to drill four holes in a reinforced concrete block, and this was

performed by 3 operators. Each operator drilled the first two holes without gloves and the next two

holes with ISO 10819:1996 certified anti-vibration gloves on. The task was performed with the

hammer function of the drill enabled (a model DeWALT D25103 with a manufacturer stated

vibration amplitude of 9.2 ms-2 in accordance to IEC 60745).

Results and Discussions

Results of A(8) for each operator show the relation between contact force values and

vibration magnitudes. Therefore contact force should be taken into consideration when evaluating

the daily exposure.

The analysis of the 1/3 octave spectrogram proved selection of exposure times to be correct

and additionally helped to evaluate the efficiency of anti-vibration gloves usage. The spectrogram

clearly showed 4 activities for all operators, however the spectrum for Operators 1 and 3 contained

lesser values on higher frequencies for the last two drills which resulted from the use of anti-

vibration gloves. Despite the use of anti-vibration gloves, the spectrogram for Operator 2 (Figure

2) showed every hole drilled at a similar frequency content. These results show that an increase of

contact force may significantly reduce the efficiency of anti-vibration gloves.

Fig. 1: SV 103 Vibration

dosimeter

Page 98: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

98

Table 1: Measurement results for 3 tasks

Operator Force threshold

N

Exposure time

mm:ss

Vector AEQ

ms-2

A(8)

ms-2

Force Aver

N

1 10 01:41 7.590 0.45 65.3

20 01:31 7.963 0.45 70.9

2

10 02:23 8.659 0.61 93.7

20 02:10 9.023 0.61 101.5

3

10 03:46 8.193 0.73 22.6

20 01:43 9.246 0.55 29.5

Figure 2 Spectrogram of 1/3 octave (Operator 2)

References

1. Jolanta Malinowska-Borowska, Barbara Harazin, Grzegorz Zieliński (2012), Measuring Coupling Forces

Woodcutters Exert on Saws in Real Working Conditions, International Journal of Occupational Safety and

Ergonomics (JOSE) 2012, Vol. 18, No. 1, 77–83

2. International Organization for Standardization (1996) Mechanical vibration and shock -- Hand-arm vibration

-- Measurement and evaluation of the vibration transmissibility of gloves at the palm of the hand, ISO 10819.

3. International Organization for Standardization (2007) Mechanical vibration and shock -- Coupling forces at

the man--machine interface for hand-transmitted vibration, ISO 15230.

4. Technical Report (2012) Mechanical vibration and shock - Hand-transmitted vibration - Influence of

coupling forces at the hand-machine interface on exposure evaluation, CEN/TR 16391

Page 99: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

99

A SURVEY ON OCCUPATIONAL HAZARDS OF COAL WORKERS USING HAND-

HELD VIBRATING TOOLS IN A NORTHERN CHINA COAL MINE

*Xiangrong Xu, Manman Gong, Zhiwei Yuan, Rugang Wang, Sheng Wang, Lihua He

Peking University Health Science Center, Beijing, China

Corresponding author: HE Li-hua ([email protected])

Introduction

Hand-transmitted Vibration (HTV), also known as Hand-arm Vibration or Segmental

Vibration, means when using hand-held vibrating tools or vibration artifacts, mechanical vibration

or shock can be transmitted to the hand and arms or act directly on workers. The exposure occurs

in many industrial productions, especially in labor-intensive manufacturing and construction

processes. In recent years, while some reports have focused on the health effects of the hand-

transmitted vibration exposure among workers in the southern part of our country, few studies

reported the exposure effects in the northern part of the country. So, this study is aimed to

investigate and analyze the vibration-induced symptoms of the coal workers who used hand-held

vibrating tools in a northern China coal mine in order to identify the impact of HTV exposure on

coal workers and to provide basic data for further research.

Methods

167 coal workers who using hand-held vibrating tools in a northern China coal mine are as

research subjects. The study received 167 valid questionnaires in total and the response rate is

100%. Subjects are all man, have a mean age of 35.1(SD±7.7) years and have a mean working

years of 5.1(SD±4.1) years.

This study conducted questionnaire investigation, health test, and vibration exposure

measurement. The sense of touch, temperature sensation and pain were measured with the

instruments made by Beijing Orient Long Technologies co., ltd. Besides, we measured hand grip

strength and examined hand and wrist by X-ray test. Human vibration analyzer (Svantek (Poland),

SV 106) was used to measure the intensity of HTV at workplaces with hand-transmitted vibration

exposure. Each workers participated in the test performed three trials at each measurement site.

The average 8h-energy-equivalent frequency-weighted acceleration, A(8), was calculated

according to the newest version of China national standard.

Database was established using Epidata 3.1 software. Double entry and validation was

adopted for all data by specially trained professional person and analysis was carried out by SPSS

16.0. We used Chi-square test and the multi-factor logistic regression analysis. The significance

level was set to 0.05.

Results

1. The intensity of hand-transmitted vibration. 8h-energy-equivalent frequency-weighted

acceleration is calculated as 6.55m/s2, exceeding the national standard which is 3.5m/s2.

2. The occurrence of self-conscious symptoms on hand and wrist. The statistically differences

of the incidence of hand numbness and hand bilges were found in different working years groups

(p<0.05). Comparing these by duration of daily exposure to vibration, we found the incidence of

hand numbness, carpal tunnel syndrome and white fingers have statistically significant differences

Page 100: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

100

(p<0.05).

3. The occurrence of self-conscious symptoms on others. The statistically differences of all these

symptoms incidence was not found in different working years groups (p≥0.05). But comparing

these by duration of daily exposure to vibration, we found the incidence of tinnitus, memory loss,

dizziness and headache have statistically significant differences (p<0.05).

4. The Physical Examination Results of coal workers. Comparing the physical examination

results of the different working years groups, we found that the abnormal rate of vibratory sense

(both hands) and the incidence of joint space narrowing have statistically significant difference

(p<0.05). What's more, comparing the physical examination results by duration of daily exposure

to vibration, we found that the differences between the abnormal rate of vibratory sense (the right

hand) and the incidence of osteosclerosis have statistically significant difference (p<0.05).

5. Analysis on risk factors of typical symptoms. The incidence of hand numbness was higher

with the working years growing and the relative risk of 6-9 years group was 9.9 times as much

as that of <3 years group (95%CI:4.75–31.08). The incidence of hand numbness increased with

duration of daily exposure to vibration and the relative risk of 2h-4h group was 36.7 times as much

as that of <2h group(95%CI: 1.61–839.92). Compared with non

drinkers, the risk for hand numbness was 4.6 (95%CI:1.51–14.02) among drinkers. Also,

compared with wearing gloves, the risk for hand numbness was 7.5 (95%CI:2.10–26.65)

among not wearing.

Discussion

The results show that HTV seriously damages workers’ health. The main self-conscious

symptoms were hand numbness, hyperhidrosis palmaris, tinnitus and memory loss. Among these,

the incidence of hand numbness was highest which was 35.5%. The physical examination results

showed that temperature sensation, pain, sense of touch and vibratory sense were abnormal, among

these, the abnormal rate of temperature sensation was highest which was 39.2%.

In this investigation, the incidence of vibration induced white finger was 4.2% which was much

lower than that in drillers of the northeast China (10.1%~45.0%). The main reason is that all the

subjects work at the state owned large coal mine enterprise were required to use the vibration

isolation gloves strictly. Secondly, the average working years are shorter. Thirdly, compared with

the northeast China, local temperature is higher.

The logistic regression analysis was used to analyze hand numbness and we found that

long working years, longer duration of daily exposure to vibration and drinking were risk factors

and wearing the vibration isolation gloves are protective factors. But with increased working years

or prolonged duration of daily exposure to vibration, workers' awareness of HTV hazards will be

enhanced. Therefore the changes were not obvious. Occupational exposure to HTV can do harm

to health. Strengthening protection and lowering intensity should be done to protect workers.

Simultaneously, technical innovation and technological transformation should be taken to

decrease the vibration and reduce the risk.

Page 101: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

101

Session IX: Tests for and Diagnosis of Health Effects II

Chairs: Paul Pitts and Ying Ye

Presenter Title and authors Page

Anthony J. Brammer Vibrotactile perception thresholds at the fingertip

measured with and without a surround

Gongqiang Yu, Anthony J. Brammer, Martin G.

Cherniack

102

Yanzhi Liu Ultrasonic observation and the significance of the

patients with hand-arm vibration disease

Yanzhi Liu, Qiongjie Lu, Xiangrong Xu, Zhimin Li,

Lihua He

104

Qingsong Chen The effectiveness of nailfold capillaroscopy in the

diagnosis of hand-arm vibration syndrome among gold

miners

Guiping Chen, Bin Xiao, Maogong Shi, Danying Zhang,

Fansong Zeng, Bei Yang, Hansheng Lin, Xuqin Cao,

Qingsong Chen

106

Page 102: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

102

VIBROTACTILE PERCEPTION THRESHOLDS AT THE FINGERTIP MEASURED

WITH AND WITHOUT A SURROUND

Gongqiang Yu+, *Anthony J. Brammer+,++, and Martin G. Cherniack+

+Ergonomic Technology Center, Health Center, University Connecticut, Farmington, CT, USA ++Envir-O-Health Solutions, Ottawa, ON, Canada

Introduction

Techniques for determining the vibrotactile sensitivity of the mechanoreceptor populations at the fingertips

by means of vibrotactile perception thresholds (VPTs) have been codified in international standards (ISO 13091-1,

and 13091-2). Statistically significant associations between vibrotactile thresholds mediated by the SAI, FAI and FAII

receptor populations at the fingertips and symptoms of deteriorating tactile acuity have been reported in a field study

of manual workers (Wakulczyk et al, 1997). Thus, well-defined VPT values for healthy persons provide important

baseline data, since they can be used to examine sensory neuropathies for clinical diagnostic purposes. However,

different equipment and methods for performing vibrotactile measurements might lead to different results. Therefore,

a specially designed instrument has been developed according to configurations specified in ISO 13091-1, and used

to measure mechanoreceptor-specific VPTs at the fingertips. Results are compared between VPTs obtained from

healthy males and females, and between VPTs obtained either with, or without, a surround.

Apparatus and Method

Twelve males (with mean age and SD of 30 ± 6 years) and nine females (aged 29 ± 5 years) who are

employees of UConn Health, with no history of neuromuscular or vascular disorders or of serious injures of the upper

extremities, participated in the tests. VPT measurements were performed using the apparatus designed and

implemented in the authors’ laboratory. The tactometer consists of a stimulator mounted on a vertically adjustable

track; an arm support on which the hand and forearm rest with palm facing upwards (as shown in Figure 1); an

accelerometer attached to the stimulator to sense the motion of a fingertip; electronics to produce short duration stimuli

of known magnitude and to process the motion; and a computer to administer the stimuli and psychophysical

algorithm, and to calculate perception thresholds. For the current study the probe diameter was 3 mm, the surround

diameter 6 mm, the force applied to the probe and surround was 0.6 N, and the nominal skin indentation was 0.5 mm.

The stimulus frequencies were 3.15, 4, 5, 20, 25, 31.5 100, 125, 160 Hz (harmonic distortion was less than 14%).

Intermittent stimulation with a rapid, "1-up-1-

down" stepped algorithm was employed, with a

step size of 2 dB/trial (the step size was initially

6 dB/trial until the subject responded). The

subjects’ skin temperature was 27-35 ºC, and

room temperature was 20-25 ºC.

Figure 1: Sketch of stimulator and fingertip-

probe/surround contact [reproduced from

Figure 1 of ISO 13091-1].

Results and Discussion

VPTs were determined at the middle and little fingers of both hands. VPT values were expressed in dB (re.

10-6 m/s2), and were averaged over the two repetitions of all the four fingers of the same subject. These VPTs were

adjusted to an age of 30 years by applying the values in Table 1 (ISO 13091-2), and to a probe diameter of 4 mm by

reducing the observed thresholds at 100, 125 and 160 Hz by 1.2 dB (Gescheider et al. 2002).

Page 103: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

103

Table 1. VPT data age adjustment/year (based on age of 30)

Frequency (Hz) 3.15 4 5 20 25 31.5 100 125 160

Adjust (dB)/year 0.03 0.03 0.03 0.08 0.08 0.08 0.25 0.3 0.35

As shown in Figure 2, this study found that male subjects possess higher (i.e., less sensitive) VPTs than

females at low frequencies (4 and 5 Hz, t-test, p < 0.01), and at high frequencies (100, 125, and 160 Hz, t-test, p <

0.005). In contrast, male and female thresholds at mid frequencies were in agreement. These frequencies are believed

to be mediated by the FAI receptors (anatomical correlate: Meisner corpuscles). As shown in Figure 3, the mean VPTs

for male subjects are in reasonable agreement irrespective of whether the probe has a surround, as shown in "Method

B" of Figure 1 (current study), or does not have a surround, as shown in "Method A" of Figure 1 (data from Brammer

et al, 2007). For the stimulation frequencies that are common to both studies (4, 20, 31.5, 100 and 160 Hz), there is

no statistically significant difference between the mean VPTs (t-test). The study without a surround employed

stimulation conditions identical to those used here except for the contact force, which was 0.05 N.

Figure 2. VPTs of male and female subjects Figure 3. Comparison of VPTs of males

in current study and Brammer at al 2007.

References

1 Brammer, A.J., Piercy, J.E., Pyykkö, I., Toppila, E., and Starck, J. (2007). Method for detecting small changes in

vibrotactile perception threshold related to tactile acuity. J. Acoust. Soc. Am. 121, 1238-1247.

2 Gescheider, G.A., Bolanowski, S.H., Pope, J.V., and Verrillo, R.T. (2002). A four-channel analysis of the tactile

sensitivity of the fingertip: frequency selectivity, spatial summation, and temporal summation. Somatosensory &

Motor Research, 19(2), 114-124.

3 ISO 13091-1 (2001). Mechanical Vibration - Vibrotactile Perception Thresholds for the Assessment of Nerve

Dysfunction - Part 1: Methods of Measurement at the Fingertips. Geneva, International Organization for

Standardization.

4 ISO 13091-2 (2003). Mechanical Vibration - Vibrotactile Perception Thresholds for the Assessment of Nerve

Dysfunction - Part 2: Analysis and Interpretation of Measurements at the Fingertips. Geneva, International

Organization for Standardization.

5 Wakulczyk, G.C., Brammer A.J., and Piercy J.E. (1997). Association between a quantitative measure of tactile

acuity and hand symptoms reported by operators of power tools. J. Hand Surgery, 22: 873-881.

Acknowledgement: Work supported by National Institute for Occupational Safety and Health research grant 5R01

OH008997

Page 104: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

104

ULTRASONIC OBSERVATION AND THE SIGNIFICANCE OF THE PATIENTS WITH

HAND-ARM VIBRATION DISEASE

*Yanzhi Liu+, Qiongjie Lu+, Xiangrong Xu+, Zhimin Li+, Lihua He++

+Shenzhen Prevention and Treatment Center for Occupational Diseases, Guangdong, China ++Peking University Health Science Center, Beijing, China

Corresponding author: Lihua He ([email protected])

Introduction

Hand-arm vibration disease (HAVD) is a legal occupational disease in China, which mainly

refers to hand peripheral circulation and (or) hand neurological dysfunction caused by prolonged

intensive exposure to hand-transmitted vibration (HTV) at workplaces. The vibration exposure

may also cause damage to bones, joints, and muscles of the arms. A considerable proportion of

workers suffering from the disease after some years of work using hand-held vibrating tools. Now,

the diagnosis of HAVD mainly depends on the patient’s history and clinical manifestations, less

application of imaging examination. In order to improve the diagnostic accuracy and the level of

diagnosis on HAVD in China, we performed high frequency ultrasound in patients with HAVD,

and analyze the ultrasonic characteristics of the median nerve and transverse carpal ligament.

Methods

We collected data from 15 patients (30 wrists) who were treated in our hospital from May

2014 to August 2015, all were male, aged between 25 to 45 years old with average age of 34.8

years old. They were exposed to HTV for 5 to 17 years, with average working years of 9.7 years.

They all met Diagnosis of occupational hand-arm vibration disease diagnostic criteria (GBZ7-

2002). All the patients worked on the grinding operation for golf products manufacturing

enterprises. Their occupational history was clear. All patients had different degrees of hand

peripheral circulation and (or) arm neurological dysfunction symptoms and signs. The main

symptoms were hand bilges, numbness, weakness, sweating, etc. Cold-water restored temperature

test showed: the restored temperature time was prolonged. EMG showed different degrees of

abnormality. Patients with the primary Raynaud's syndrome, peripheral vascular obstruction as

well as lead, mercury and other occupation poisoning history were excluded. At the same time, 20

healthy volunteers (40 wrists) were selected as the control group, and all were male, aged between

27 to 44 years old with an average of 35.7 years. We used color Doppler ultrasonic diagnostic

apparatus (GE E9 LOGIQ). Probe frequency was 6-15MHZ, initial set to muscle test conditions.

We used SPSS 17 statistical software for statistical analysis. The measurement data were expressed

by means of mean±SD. The mean was compared by t-test and the significance level was set to

0.05.

Results

The transverse carpal ligament of 15 patients (30 wrists) with HAVD and 20 cases (40

wrists) of the control group showed a strong hyperechoic and separated in the meantime hypoecho

band. The median nerve transection in the two groups was round, oval and low echo area.

Longitudinal section showed parallel, streaky and low echo area. 15 cases (30 wrists) with HAVD

were not detected inhomogeneous echo enhancement of the carpal transverse ligament, median

nerve swelling, and the echo blurred. There was no obvious difference in the morphology and the

Page 105: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

105

echo of the two groups.

In 15 cases (30 wrists) with HAVD, the patients' carpal transverse ligament thickness at

the hook of the hamate bone was (0.33±0.05) cm, the median nerve diameter was (0.22±0.02) cm.

Compared with the control group separately, the differences were not statistically significant

(p>0.05).

15 cases (30 wrists) with HAVD who were (0.08±0.02) cm2 compared with the control

group who were (0.10±0.01) cm2 in the median nerve area at the hook of the hamate and pisiform

bone, the difference was not statistically significant (p>0.05).

Discussion

Cold-water restored temperature test and the electro-physiological examination cannot

directly reflect the adjacent relationship and provide the morphological changes caused by nerve

compression. But clinicians also want to understand the relationship between peripheral nerve and

blood vessels, so it is becoming more and more important for the study of imaging diagnosis. At

present, although X-ray, magnetic resonance imaging and so on can be displayed directly, yet it is

time consuming and expensive. However, as a traditional diagnostic method, ultrasonagraphy is

widely used in clinical practice because of its advantages, such as real-time, direct, noninvasive,

low price and so on. With the development of ultrasonic technology, the resolution of high

frequency ultrasound has reached 400μm, and it can clearly show the nerve tissue around it. And

compared with magnetic resonance imaging, it is easier to observe the real-time activity of nerve

and tendon. The anatomy of the median nerve is always in contact with the transverse carpal

ligament, which is especially helpful to the recognition of ultrasonic images.

In the research of HAVD with X-ray and magnetic resonance imaging, in addition to the

display of patients with wrist joint bone sclerosis, osteoporosis, and wrist joint necrosis, magnetic

resonance imaging also shows the damage of the joint fluid and soft tissue. In the application of

ultrasonagraphy in this group: 15 cases (30 wrists) with HAVD were not detected inhomogeneous

echo enhancement of the transverse carpal ligament, median nerve swelling, and the echo blurred.

There was no significant difference in the morphology and echo between the two groups. No

obvious effusion and soft tissue injury were found in the joint cavity. This study has not yet

indicated that the arm vibration may cause damage to the wrist and middle nerve, but the cause of

the arm vibration disease is more complicated. Whether or not it will cause damage to the wrist of

the patient needs further research.

In some study, patients with HAVD mainly showed the prolongation of the distal motor

latency of median nerve and ulnar nerve. In this study, 15 cases (30 wrists) with HAVD and the

control group (20 cases, 40 wrists) shows no statistical significance in comparison of transverse

carpal ligament thickness at the hook of hamate bone and median nerve diameter. Combined with

the related research, HAVD may have a functional effect on the patient's median nerve. But the

effect on the morphology of the median nerve and the transverse carpal ligament was not obvious.

But there are few data collected at present, and the influence of the median nerve and transverse

carpal ligaments in the patients still need to be further explored.

Ultrasound examination can be clear to show the contents of carpal tunnel imaging changes

by combination of static and dynamic display, observe its morphology and echo performance,

particularly, measure the thickness and the inner diameter of the median nerve, and quantify the

cross-sectional area of the wrist. So we suggest that this can be used as a new diagnostic criteria

for clinical diagnosis of HAVD to provide an objective and scientific basis for diagnosis.

Page 106: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

106

THE EFFECITVENESS OF NAILFOLD CAPILLAROSCOPY IN THE DIAGNOSIS OF

HAND-ARM VIBRATION SYNDROME AMONG GOLD MINERS

Guiping Chen+, Bin Xiao+, Maogong Shi++, Danying Zhang+, Fansong Zeng+, Bei Yang++,

Hansheng Lin+, Xuqin Cao+, *Qingsong Chen+

+Guangdong Province Hospital for Occupational Disease Prevention and Treatment; and

Guangdong Provincial Key Laboratory of Occupational Disease Prevention and Treatment,

Guangzhou, Guangdong 510300, China ++Occupational Disease Hospital of Yantai City, Shandong 264000, China

*Correspondence to: [email protected]

Introduction

Hand-held vibrating tools operated by workers over a long period of time can lead to the

development of hand-arm vibration syndrome (HAVS)1. Among the symptoms of the syndrome,

vibration-induced white finger (VWF) is the most typical. Capillaroscopy is extensively utilized

in the clinical diagnosis of Raynaud’s syndrome, but it is relatively less frequently used in the

diagnosis of HAVS. The purpose of this study was to investigate the effectiveness of

nailfoldcapillaroscopy on the diagnosis of HAVS.

Methods

A total of 114 male gold miners were recruited, 35 with HAVS, 39 without HAVS as vibration-

exposed controls (VEC), and 40 as non-vibration-exposed controls(NVEC). Video of

capillaroscopy was used to capture images of the 2nd,3rd, and 4th fingers of both hands of all subjects

at heart level after 10 minutes of rest at a room temperature of 20°C. The number of capillaries/mm,

avascular areas, microhemorrahages, and enlarged capillaries were evaluated under blinded

conditions2,3. The effectiveness of nailfoldcapillaroscopy on the diagnosis of HAVS was

systematically assessed by statistical differences in morphological criteria among the groups as

well as sensitivity and specificity according to ROC curve analysis.

Results and Discussions

Significant differences in morphological criteria (avascular areas, microhemorrhages, and

enlarged capillaries, Figure1) existed between the groups (P<0.05; Table 1). Avascularareas in

HAVS, VEC, and NVEC appeared in 74.3%, 43.6%, and 25.0%of subjects, respectively. A higher

percentage of subjects had microhemorrhages in the HAVS group (65.7%) compared with the other

groups (VEC: 7.7% and NVEC: 7.5%). As shown in Figure 2, the number of capillaries/mm ROC

Curve(95%CI) had cut-off value 8.25 capillaries/mm, sensitivity 68.6% and specificity 79.5%,

with an area of 0.780(0.684, 0.877, P<0.001).

Nailfold capillary damage in gold miners was more severe in HAVS patients than in VEC and

NVEC subjects. This suggested that nailfold microcirculation morphological criteria (ie, the

number of capillaries/mm, avascular areas, microhemorrahages, and enlarged capillaries) had high

value in the diagnosis of HAVS.

Page 107: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

107

(a) Avascular area (b)Microhemorrhage (c)Enlarged capillary

Figure1.Variations of abnormal nailfold capillaries

Table1: Morphological criteria

HAVS(n=35) VEC(n=39) NVEC(n=40) P

Microhemorrhages,n(%) 23(65.7)a,c 3(7.7) 3(7.5) <0.001

Enlarged capillaries,n(%) 21(60.0)c 10(25.6)b 10(25.0) 0.04

Avascularareas,n (%) 26(74.3)c 17(43.6) b 10(25.0) <0.001

Number of capillaries/mm,mean±SD 7.41±1.79a,c 8.87±1.80b 9.69±1.22 <0.001 aHAVS vs. VEC:P<0.05;bVEC vs. NVEC:P<0.05;cHAVS vs. NVEC:P<0.05.

(a) Number of capillaries/mm boxplot(b) Number of capillaries/mm ROC Curve

Figure 2: Number of capillaries/mm boxplot and ROC Curve

References

1. Busi Nayantumbu, Chris M. Barber, Mary Ross et al. (2007). Hand-arm vibration syndrome in South

African gold miners. Occupational Medicine 57: 25-29.

2. MaurizionCutolo, Carmen Pizzorni, Alberto Suli (2005). Capillaroscopy. Best Practice & Research

Clinical Rheumatology 19(3): 437-452.

3. Francesca Ingegnoli, Roberta Gualtierotti, Chiara Lubatti et al. (2013). Nailfold capillary patterns in

healthy subjects: A real issue in capillaroscopy. Microvascular Research 90: 90-95.

Page 108: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

108

Session IX: Prevention, Intervention, and Training

Chairs: Paul-Émile Boileau and Qingsong Chen

Presenter Title and authors Page

Hans Lindell Zero vibration injuries – a Swedish holistic approach

fighting vibration injuries

Hans Lindell

109

Alice Turcot The engineer and the physician: can they understand each

other when they talk about machine vibration?

Alice Turcot, Marie Fortier

111

Mallorie Leduc Building awareness: hand arm vibration syndrome

training and education in the construction industry

Mallorie Leduc, Ron House, and Tammy Eger

113

Karim Hamouda Performance evaluation of vibration-reducing gloves at

the fingers using finger adapter

Karim Hamouda, Pierre Marcotte, Subhash Rakheja

115

Page 109: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

109

ZERO VIBRATION INJURIES – A SWEDISH HOLISTIC APPROACH FIGHTING

VIBRATION INJURIES

Hans Lindell

Swerea IVF, Box 104, 431 22, Mölndal, Sweden

[email protected]

Introduction

Vibration injuries constitute the second most common cause of occupational injuries

among males in Sweden and the incidence among women is steadily increasing1. In the current

situation several industry sectors do not comply with EU directives2,3 for vibration exposure often

due to no availability of machines with low vibration levels. Also in areas where there are effective

technical solutions, lack of knowledge is an important factor leading to constant or increasing

vibration injury. The problem is complex and needs a broad co-operation in the society in order to

be solved. The machine producers don’t experience that there is a demand for low vibration

machines and have difficulties to find robust technical solutions, and the machine users on the

other hand often have difficulties to find low vibrating alternatives. The occupational medicine

cannot cure the injuries. The Swedish work environment authority, employer and labor

organizations also have difficulties to effectively address the problem. The economic cost of

vibration injury is significant in Sweden. According to Swedish Parliament Research Service4 the

total health insurance expenditure for all diagnoses that can be associated with vibrations in 2009

is estimated to about 7 billion SEK annually.

However the project “Zero Vibration Injuries” is a Swedish initiative with the objective to

take a holistic approach on the problem. It is starting in June 2015 and will end in August 2017

and is financed by the Swedish Innovation Agency, Vinnova. The project is holistic in the sense

that the consortium involves all stakeholders in the society, i.e. machine manufacturers, a

comprehensive range of machine users, the Swedish work environment authority, employer and

labor organizations together with occupational medicine and vibration researchers. The consortium

will have a great potential to set requirements on vibrating machines and bring about change in

society.

The strategy is to develop low vibration concept prototypes representing main problem

areas which will then form the basis for specifying requirements on manufacturers from the user

side. The project will demonstrate that machines do not need to vibrate and injure people. The

development of low vibration machines will be based on newly developed technology with

Nonlinear Tuned Vibration Absorbers5 for machines with a reciprocating action and Automatic

Balancing6 for those with rotating vibrations. Also the high frequency content of vibrations above

1250 Hz, that ISO 5349 does not include, will be reduced since it is believed to cause substantial

vibration damage.

EU has a comprehensive regulatory framework from 2005 to deal with vibration injuries.

This constitutes the Vibration Directive stipulating maximum vibration dose and requirements for

health checks but also by the Machine Directive. The Machine Directive provides that machine

manufacturers are obligated to make use of state-of-the-art technology for vibration reduction and

declare how much the machines vibrate. The problem of vibration injuries is not about a lack of

regulation but primarily of non-compliance, which in turn is largely due to lack of low vibration

Page 110: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

110

machine alternatives and legal enforcement from authorities. An excellent summary of the current

situation and history behind is made by P. Donati7.

Methods

The project has two main approaches to address the vibration problem.

The first approach is to develop representative conceptual machines with a hand-arm

weighted vibrations target level below 2.5 m/s2 and with reduced high frequency content,

i.e. >1250 Hz. This is accomplished by using newly developed technology for reciprocating

machines and automatic balancing for rotating machines together with traditional vibration

reduction approaches.

The second approach is to take precautions against high frequency transient impact

vibration. There are numerous findings8-11 that indicate that the acceleration weighting curve in

ISO 5349 is not sufficient to cover effects from high frequency and transient vibrations which is

also stated in the standard itself. Reducing high frequency vibrations is from a technical

perspective generally much easier than at lower frequencies but today there is no incentive for

machine manufacturers since there is no standard to measure it. Hopefully will this change in the

near future. The conceptual machines will have a low level of high frequency vibrations, i.e

frequencies above 1250 Hz.

The low vibration conceptual machines will after completion form the basis for

specification requirements from the machine user industry and will in turn both push and give

incentive for the machine producer industry to adopt new technology and develop machines that

do not injure the operator. In this way the project hopes to make a substantial contribution to a

society where occupational injuries by vibrating machines are less frequent.

References

1. AFA Försäkring Arbetsskaderapport 2014, In Swedish.

2. EU Machine Directive (1989/392/EC)

3. EU Vibration Directive (2002/44/CE)

4. Riksdagens Utrednings Tjänst, Arbetsmiljöfrågor – Vibrationer, Dnr:2012:822

5. Lindell H. Patent WO 2014/095936 A1

6. Lindell H, (1996) “Vibration reduction on hand-held grinders by automatic balancing”, Central European journal

of public health 4, No 1, 43-45

7. Donati P. “Joël’s Breaker: Forty Years of European Vibration Prevention” Industrial Health 2012, 50, 370–376

8. Barregård L. et al. Investigation of car repair shop workers in Gothenburg - Report 1 & 2, (1992)

9. Lindell H, Lönnroth I, Ottertun H. (1998) Transient vibration from impact wrenches: Vibration negative effect

on blood cells and standards for measurement, Eighth International Conference on Hand-Arm Vibration, Umeå,

Sweden, June 9-12, 113-117

10. Hideo Ando et al. Effect of impulsive vibration on red blood cells in vitro, Scand J Work Environ Health

2005;31(4):286-90.

11. Govinda Raju, S. et al. Vibration from a riveting hammer causes severe nerve damage in the rat tail model,

Muscle&Nerve, Volume 44, Issue 5, p. 795–804, 2011

Acknowledgements

This project was funded by AFA Insurance and the Swedish Innovation Agency VINNOVA.

Page 111: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

111

THE ENGINEER AND THE PHYSICIAN: CAN THEY UNDERSTAND EACH OTHER

WHEN THEY TALK ABOUT MACHINE VIBRATION?

*Alice Turcot, Marie Fortier

Institut national de santé publique du Québec, Québec, CANADA

Introduction

Hand-arm vibration syndrome (HAVS) is a disease related to exposure to the vibrations generated by

vibrating tools. In Québec, it is estimated that 400,000 workers are exposed to hand-arm vibration from grinders,

concrete breakers, orbital sanders, pneumatic wrenches, chain saws, jack hammers, etc.1 However, the number of

workers exposed to whole-body vibration (WBV) is not known.

HAVS consists of three distinct types of diseases, namely vascular disease, neurologic disease and

musculoskeletal disease. These three types of diseases can evolve simultaneously or separately and threaten the quality

of life of the workers affected. We are dealing with a complex disease whose pathophysiological mechanisms are still

not completely understood. Risk evaluation by measuring the acceleration of the vibrations requires training in

measurement itself and specific knowledge in order to properly evaluate the factors that could limit the analysis, such

as working postures, the presence of impacts, the gripping and thrusting strength, etc. In fact, the biodynamic

behaviour of the hand-arm system subjected to vibration is complex. All of the parameters that come into play in risk

evaluation still have to be mastered. Different modalities developed by engineers allow biodynamic behaviour to be

studied, including modeling. The same is true for the study of WBV relating to risk assessment and risk prevention

measures, the health effects that must be better described, and the modeling that allows a better understanding of the

behaviour of the whole body subjected to vibration.

Study of HAVS and the diseases linked to WBV therefore requires knowledge belonging to at least two

different disciplines, namely medicine and engineering. Does a common language base exist as well as a desire to

implement interdisciplinary action between physicians and engineers? Can these experts understand each other? The

goal of the present study is to document whether a common base of exchanges exists between these two disciplines,

and to document the obstacles or issues, to allow interdisciplinary practice and to ensure an effective transfer of

knowledge between the two disciplines.

Methods

To answer these questions, we analyzed the university curriculum in Québec in the fields of medicine and

engineering, specifically the types of courses planned in the undergraduate, master's and doctoral programs that

address occupational health and safety in these respective disciplines. Subsequently, we identified the number of

scientific presentations that refer to an interdisciplinary study in the context of international and American conferences

since 2001 dealing with hand-arm vibration or WBV. Finally, using a semi-structured questionnaire, we proceeded to

analyze the content of interviews conducted with physicians (n=5) and engineers (n=5), representing academia and

having worked directly or indirectly on the prevention of vibration. The duration of the interviews varied from 1.5

hours to two hours.

Results and Discussion

The study revealed a certain number of obstacles and barriers in interdisciplinary collaboration. In particular,

regarding the university curriculum of these two disciplines, the diversity and abundance of knowledge on both sides

do not allow sufficient attention to be paid to the issue of vibration in occupational health. However, two studies show

that the interdisciplinary collaboration introduced in university training is providing winning results for future

physicians when medical disciplines that already share a common language are involved.2,3 The situation is very

different with engineering and medicine because they do not have a common knowledge perspective. Analysis of the

academic curriculum, for physicians as well as engineers, reveals that risk measurement, knowledge of the health

effects, and the understanding of preventive measures are fragmentary.

Between 2001 and 2014, 14 American or international conferences dealt with hand-arm or whole-body

vibration. However, based on the retrieval of topics in conference proceedings, interdisciplinary collaboration remains

Page 112: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

112

fragmentary and limited. Research on the biomechanical aspects of vibration, on preventive measures, and on the

medical and diagnostic aspects of disease, remains active without being networked in Canada.

While preliminary, this study also identified major obstacles in physician-engineer collaboration in the field.

These obstacles relate to the complexity of the risk and to all of the technical parameters that must be taken into

account in measurement; the unfamiliarity with measurement methods for engineers as well as physicians; the difficult

updating of knowledge about vibration in the vast field of occupational health priorities; the versatility of occupational

health physicians, limiting their specialization with respect to vibration; the lack of a culture of exchanges regarding

the solving of problems in the field of vibration; the lack of recognition of vibration as a priority health problem; and

research funding determined by "popular" topics where vibration is not included, etc. The results of a prior study on

risk perception had already shown the lack of awareness of risk, by physicians, workers, and employers.4 A survey in

United States has shown that a large portion of the surveyed American Society of Safety Engineers safety and health

members haven’t heard of WBV, suggesting enhanced efforts by governmental, professional, and educational

organizations to increase WBV topic knowledge among safety and health practitioners.5 As a result, it is not surprising

to note that interdisciplinary collaboration is problematic. To make up for this lack of a common language between

the two disciplines, it would be beneficial to establish a community of practice, in order to create a common space for

exchanges between the experts from the different disciplines, including clinicians.

Furthermore, the present study shows that efforts must be made in the transfer of knowledge. This could be

achieved by stages determined in the literature.6 Also, research topics such as the characterization of vibration

exposure in mining vehicles; or even measurement of the vibration emitted from different tools, under simulated

laboratory conditions; the contribution of factors such as gripping strength to the transmissibility of the vibration to

the hand-arm system; the measurement of vibration according to different ISO standards; the understanding of the

variation in sensitivity of the human body, based on the different frequencies of the vibration spectrum, based on the

measurement axis, or even according to the hand-seat-foot location; modeling; the analysis of the dynamic response

of a finger exposed to vibration by using finite element models, are many examples of topics involving a language

belonging to engineers, difficult for occupational physicians in the field to adopt, and requiring particular attention to

the factors promoting the transfer of knowledge at all stages in the process.

The challenges of occupational physicians and engineers do not seem to dovetail. More specific ergonomic

knowledge in the university curricula of both disciplines could possibly be the beginning of a common basis for the

work of engineers and occupational physicians.

References

1. Martin, R. et al. (2004). Estimation du nombre de travailleurs québécois exposés à des vibrations au-delà du

seuil d’intervention, Agence de santé et des services sociaux de Chaudière-Appalaches, Direction de la santé

publique, Sainte-Marie de Beauce, Québec, Canada.

2. Nørgaard, B., Draborg, E., Vestergaard, E., Odgaard, E., Jensen, D.C., and Sørensen, J. (2013). Interprofessional

clinical training improves self-efficacy of health care students. Medical Teacher 35(6): e1235-e1242.

3. Hallin, K., Kiessling, A., Waldner, A., and Henriksson, P. (2009). Active interprofessional education in a patient

based setting increases perceived collaborative and professional competence. Medical Teacher 31(2): 151-157.

4. Tessier, B., and Turcot, A. (2012). Perceptions à l’égard des risques reliés à l’utilisation des outils vibrants en

milieu de travail. Agence de la santé et des services sociaux de Chaudière-Appalaches, Direction de santé

publique, Sainte-Marie de Beauce, Québec, Canada.

5. Paschold, H.W. (2008). Survey of whole-body vibration awareness and knowledge among safety and health

professionals in the United States. 2nd American Conference on Human Vibration, Proceedings, June 4-6, pp. 81-

82.

6. Lemire, N., Souffez, K., and Laurendeau, M.C. (2009). Animer un processus de transfert des connaissances, Bilan

des connaissances et outil d’animation. Institut national de santé publique du Québec, Direction de la recherche

et développement, Québec, Canada, No publication 1012, p. 13.

Page 113: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

113

BUILDING AWARENESS: HAND ARM VIBRATION SYNDROME TRAINING AND

EDUCATION IN THE CONSTRUCTION INDUSTRY

*Mallorie Leduc+, Ron House++, and Tammy Eger+

+Centre for Research in Occupational Safety and Health, Laurentian University,

Sudbury, ON, Canada, ++University of Toronto & St. Michael’s Hospital, Toronto, ON, Canada,

Introduction

Exposure to hand operated vibrating tools within the construction industry places workers

at risk for developing hand-arm vibration syndrome (HAVS). Damage to the vascular,

neurological, and musculoskeletal systems of the hand and arm is typically progressive with

continued vibration exposure and often irreversible. As such, prevention efforts are imperative for

the management of HAVS. The use of anti-vibration (AV) gloves is often recommended as

personal protective equipment while operating vibrating tools. In Ontario, Canada, it is the duty of

an employer to “provide information, instruction and supervision to a worker to protect the health

or safety of the worker.”1 In 2014, basic worker health and safety awareness training was made

mandatory for all workers in Ontario. The training outlines the duties of the workers, supervisors,

and employers according to the Occupational Health and Safety Act, common workplace hazards,

participation in joint health and safety committees, and additional resources within Ontario’s

workplace health and safety system. Furthermore, fall protection training for workers working at

heights and Workplace Hazardous Materials Information System (WHMIS) training for the safe

use, storage and removal of chemicals and hazardous materials in the workplace is mandatory

within the industry. However, without education focused specifically on prevention and reduction

strategies of HAVS in the construction industry, a continued lack of awareness and under-

recognition of the common occupational disease will persist. The purpose of the study was

twofold: (1) to outline health and safety training obtained by construction workers, and (2) to assess

which factors influence AV glove utilization of construction workers following an educational

intervention and occupational health clinic assessment for HAVS.

Methods

100 workers from the construction industry referred for an assessment of HAVS at a

hospital-based out patient occupational health clinic in Toronto, Ontario, Canada were recruited.

A baseline questionnaire was given to all participants at their assessment, which documented their

prior health and safety training opportunities and AV glove utilization. A HAVS education

resource, a one page double-sided laminated document, was given to all participants. Participants

were given three copies and were asked to distribute at their respective workplace. Two months

following the assessment and educational intervention, a follow up questionnaire was mailed to all

participants. The training results were analyzed using descriptive statistics and a stepwise logistic

regression was used to assess the predictors of AV glove utilization following the educational

intervention and assessment.

Page 114: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

114

Results and Discussions

Almost all of the participants indicated they had completed health and safety training

within their workplace (90% Occupational Health and Safety Act, 96% WHMIS, 85% general

health and safety training). In contrast, only 5% received HAVS training while 49% indicated they

received some form of other training regarding the use of protective gloves. However, only 8%

received training on AV gloves in particular. Only 4.1% of the participants reported wearing AV

gloves when exposed to hand-arm vibration at baseline.

57 participants completed the follow-up questionnaire. Following assessment at the

occupational health clinic and receiving the educational intervention, 42.9% indicated to have

increased their use of AV gloves. Associated with increased AV glove use was participants sharing

of the educational information with their employers, supervisors and health and safety

representatives. A logistic regression was performed to ascertain the effects of information sharing

on the likelihood of participants increasing AV glove use. The logistic regression model was

statistically significant, χ2(1) = 13.349, p < .001. The model explained 34.3% (Nagelkerke R2) of

the variance in AV glove use and correctly classified 75.6% of the cases. Only one predictor

variable was statistically significant: sharing the information with their employer. Participants who

share the educational information with their employer had 14.67 times higher odds to increase AV

glove use than those who did not share the educational information with their employer.

The current health and safety training opportunities within the construction industry are

not adequately preventing and protecting workers from HAVS. Training opportunities targeted

specifically on education and the prevention of HAVS are rarely being offered to workers. The

educational intervention proved most effective in increasing AV glove use when the information

was shared within the workplace, especially with the participant’s employer. Therefore, the

employer is an important component in leading positive behavior change of their employees.

HAVS focused education may be a missing and integral role in the prevention and recognition of

HAVS within the workplace. Increasing the knowledge of workers may improve their ability to

seek appropriate medical treatment and begin dialogue with physicians’ related to the origin of

their symptoms and may indirectly influence the reporting of occupational diseases2. Furthermore,

the purchasing of tools with lower vibration emission values, process changes, reduction in

employee exposure duration, and provision of additional education opportunities regarding HAVS

were also important control changes made by the employer that occurred at many worksites as a

result of the educational intervention3. Creating dialogue and increasing awareness and education

of HAVS within the workplace at both the worker and employer level should be considered

moving forward.

References

1. Occupational Health and Safety Act, RSO (1990). C 0.1, Section 25(2)(a).

2. Curti, S., Sauni, R., Spreeuwers, D., De Schryver, A., Valenty, M., Riviere, S., Mattioli, S. (2015).

Interventions to increase the reporting of occupational diseases by physicians. Cochrane Database of

Systematic Reviews. Issue 3. Art No.: CD010305.DOI:10.1002/14651858.CD010305.pub2.

3. Thompson, A.M.S., House, R., Holness, D.L. (2012). Education of employers and employees on

effective prevention of hand-arm vibration syndrome: results of an innovation grant study.

Proceedings from the 4th American Conference on Human Vibration. June 13-15th, 2012. Hartford,

USA.

Page 115: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

115

PERFORMANCE EVALUATION OF VIBRATION REDUCING GLOVES AT THE

FINGERS USING FINGER ADAPTER

*Karim Hamouda+, Pierre Marcotte++, Subhash Rakheja+

+Concave Research Centre, Concordia University, Montreal, QC, Canada ++IRSST, Montreal, QC, Canada

Introduction

Vibration-reducing (VR) gloves are widely used in many industries to protect workers from

exposure to vibration transmitted by hand-held power tools. Effectiveness of different VR gloves

in reducing hand-transmitted vibration (HTV) has been extensively investigated through

measurements at the palm using standardized palm-adapter1. Vibration transmission properties of

VR gloves to the fingers, however, have been addressed in only a few studies2. Moreover, the

standardized procedure for assessing vibration attenuation performance of VR gloves requires

measurement of vibration transmission at the palm only, assuming similar vibration transmission

to the fingers. The reported studies, however, have shown substantial differences between the

palm- and finger-vibration transmissibility characteristics2. In this study, a finger adapter is

designed to measure finger vibration transmission properties of different VR gloves, in addition to

the palm vibration transmission using the standardized palm adapter.

Methods

Palm-and finger vibration transmission of 12 different

VR gloves were measured in the laboratory with 12

subjects. Measurements were performed on an

instrumented handle, capable of monitoring hand-grip

and push forces, mounted on a vibration exciter, as

described in ISO 108191. Test gloves included air, gel,

gel-foam, hybrid and leather. The standardized palm

adapter, containing a miniature three-axis accelerometer,

was used to measure vibration at the palm. A reported

study has observed peak fingers vibration near middle

phalanges of index and middle fingers. Two Velcro finger

vibration adapters, each containing a miniature three-axis

accelerometer, were thus designed to measure vibration

near mid-phalanges of index and middle fingers. Each

glove was cut near these locations so as to tightly secure

finger adapters on the gloved hand of each subject, as

shown in Fig. 1. Repeatability and reproducibility of

measurements were thorough evaluated through repeated

measurements under a band-limited random vibration in the 25 to 1600 Hz range, as defined in

ISO 108191. Palm and finger vibration responses of gloves were subsequently acquired for each

subject, while subject grasped the handle with 30 N grip and 50 N push force. Each measurement

was repeated twice and data were analyzed to obtain palm as well as fingers vibration

transmissibility characteristics of the VR gloves.

Fig. 1: Gloved hand with fingers

adapters

Fig. 1: Gloved hand with fingers

adapters

Page 116: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

116

Results and Discussions

Figure 2 shows the palm and fingers vibration transmissibility characteristics of 12 gloves,

averaged over the 12 subjects. Figure also shows mean transmissibility measured with bare hand (BH) of

the subjects. The finger responses of VR gloves are presented for both the middle- and index-fingers. The

overall vibration isolation effectiveness of each glove was evaluated from the frequency-weighted rms

accelerations using the total effective acceleration transmissibility (TEAT) method3. Identical weighting

was used for both the palm and the fingers vibration. Table 1 summarizes overall vibration transmission to

the palm and fingers with different gloves used in the study. While the air gloves are considered as VR

gloves according to ISO 108191, the index and middle fingers’ transmissibility characteristics show

vibration amplification in mid-frequency range and only limited attenuation in high-frequency range.

Fig. 2: Bare and gloved hand; 1/3 octave band frequency response for (a) palm, (b) index and (c) middle fingers.

Table 1: Weighted M- and H- vibration transmissibility of gloves measured at the palm and fingers.

Palm Index Middle

Glove M -

Spectrum

H -

Spectrum

M -

Spectrum

H -

Spectrum

M -

Spectrum

H -

Spectrum

Air 1 0.81 0.59 1.30 0.96 1.24 0.92

Air 2 0.81 0.65 1.83 0.75 1.38 0.91

Air 3 0.79 0.63 1.74 0.80 1.28 0.89

Gel 1 0.95 1.02 1.84 1.08 1.29 1.21

Gel 2 0.82 0.55 1.90 0.50 1.53 0.78

Gel 3 0.87 0.82 1.73 0.80 1.29 0.91

Foam Gel 1 0.94 1.02 1.80 1.09 1.26 1.22

Foam Gel 2 0.89 0.81 1.77 1.01 1.33 0.98

Hybrid 1 0.77 0.57 1.71 0.93 1.21 1.11

Hybrid 2 0.80 0.63 1.74 0.92 1.23 1.11

Hybrid 3 0.79 0.61 1.73 0.91 1.21 1.07

Leather 0.95 1.05 1.78 1.39 1.24 1.22

References

1. ISO 10819 (2013). Mechanical Vibration and Shock - Method for the Measurement and Evaluation of the

Vibration Transmissibility of Gloves at the Palm of the Hand, Geneva, Switzerland.

2. Welcome, D.E., Dong, R.G., Xu, X.S., Warren, C. & McDowell, T.W. (2014). The effects of vibration-reducing

gloves on finger vibration. Int.J.Ind.Ergonomics 44: 45-59.

3. Dong, R., Rakheja, S., Smutz, W., Schopper, A., Welcome, D. & Wu, J. (2002). Effectiveness of a new method

(TEAT) to assess vibration transmissibility of gloves. Int.J.Ind.Ergonomics 30: 33-48.

Page 117: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

117

Index of Authors

Almagirby Almaky 62 Grétarsson Snævar

Leó 42

Bain James 7 Griffin Michael J. 22

Berbyuk Viktor 42 Gunnarsson Lars-

Gunnar 95

Bochmann Frank 93 Hagberg Mats 16

Boileau Paul-Émile 73 Hamouda Karim 115

Botti Teresa 60,84 Harada Noriaki 14

Brammer Anthony J. 12,91,102 Hase Ryosuke 14

Bruchmueller Tim 75 He Lihua 9,99,104

Bryngelsson Ing-Liss 95 Holness L 18

Burström Lage 3 Hossain Mahbub 14

Byrnell Heather 36 House Ron 18,82,113

Cao Xuqing 5,24 Hua Yue 67

Cao Xuqin 106 Huang Hanlin 49

Carré Matt J. 62 Inclima Rick 38

Cerini L. 84 Ishitake Tatsuya 14

Chen Guiping 5,24,47,51,106 Johanning Eckardt 38

Chen Qingsong 5,24,47,49,51,106 Josefsson Mattias 42

Cherniack Martin G. 102 Kalra M. 33

Dewangan Krishna 33 Kaulbars Uwe 29,93

Dickey James P. 36 Kawano Yoshinao 14

Dong Ren G. 27,44,54,56,69 Kuczynski Jacek 97

Eckert Winfried 93 Kurozawa Youichi 14

Eger Tammy 36,82,113 Landsbergis Paul 38

Fattorini L. 88 Lang Li 5,24,49,51

Fortier Marie 111 Leduc Mallorie 82,113

Ganghoffer Jean-François 67 Lemerle Pierre 67

Gerhardsson Lars 16 Li Zhimin 104

Germann René 79 Li Hongling 51

Gillstrom Lennart 16 Lin Hansheng 5,24,47,49,106

Giovanni Raoul Di 60,84,88 Lindell Hans 42,109

Godwin Alison 36 Lindgren Bernt 95

Goggins Katie 82 Liu Yanzhi 104

Gong Manman 9,99 Lu Qiongjie 104

Graff Pål 95 Lunghi Alessandro 60,84,88

Page 118: Proceedings _ Part II _ Collection of Abstracts - 09-30-2015

118

Mangold Sebastian 75,77,79 Toibana Norikuni 14

Marchetti Enrico 60,84,88 Truenkle Bernhard 75

Marcotte Pierre 33,115 Turcot Alice 86,111

Matthiesen Sven 75,77,79 Vihlborg Per 95

McDowell Thomas W. 44,54,56,69 Wahlström Jens 3

McKay Siobhan C. 20 Wang Shu 73

Moleti A. 84 Wang Rugang 9,99

Nilsson Tohr 3 Wang Sheng 9,99

Noël Christophe 58,71 Warren Christopher 27,44,54,56

Persson Magnus 7 Welcome Daniel E. 27,44,54,56,69

Pitts Paul 91 Wu John Z. 54,56,69

Rakheja Subhash 33,73,115 Xiao Bin 5,24,47,49,51,106

Rempel David 31 Xie Lan 64

Riley Danny 7 Xu Xiangrong 9,99,104

Rongong Jem A. 62 Xu Xueyan S. 44,54,56

Ruel-Laliberté Jessica 86 Xu Guoyong 24,47

Sacco Floriana 60,84,88 Yan Maosheng 51

Saggin Bortolino 40,64 Yan Hua 5,47

Sanjust Filippo 60,84 Yan Maosheng 5,47

Scaccabarozzi Diego 40,64 Yang Aichu 5,24,49

Schäfer Tobias 77 Yang Bei 106

Schmidt Sebastian 77 Ye Ying 22

Shi Maogong 106 Yu Gongqiang 102

Shiralkar Sandy P. 20 Yuan Zhiwei 9,99

Sinsel Erik W. 27 Zeng Fansong 5,49,51,106

Sisto Renata 60,84 Zhang Danying 24,51,106

Stelzer Daniel 75 Zimmerman Jordan 7

Sun Yi 93

Takahashi Tsunehiko 14

Tang Shichuan 47,49

Tarabini Marco 40,64

Taraschuk I 18

Thompson Aaron 82

Tirabasso Angelo 60,84,88