pretium edge tap module installation and testing

9
SRP 003-126, Issue 1 STANDARD RECOMMENDED PROCEDURE 003-126 | ISSUE 1 | OCTOBER 2012| PAGE 1 OF 9 | PRETERMINATED SYSTEMS | CABLES | CONNECTORS | CABLE ASSEMBLIES | HARDWARE | TOOL KITS AND ACCESSORIES | TEST EQUIPMENT | SPLICE EQUIPMENT | FAN-OUT KITS | Pretium EDGE ® Tap Module Installation and Testing 1. General 1.1 This procedure describes Pretium EDGE Tap Modules, which are available for both multimode and single mode applications. Compatible with all Pretium EDGE rack-mountable connector housings, TAP modules have twelve front-mounted shuttered LC adapters and two MTP ® connectors in back (Figure 1). 1.2 The module contains 12 fiber optic splitters which divide the incoming optical signals into two outputs, one for live link traffic and one for monitoring. The monitor traffic is routed via the “TAP”-labeled MTP connector to a monitoring device which filters the data and sends it to various software tools for analysis, where it is then viewed in application-layer software for security threats, performance issues, or system optimization. IMPORTANT: Please note that Tap module systems have two outputs for each input, which may require two power meters, and depending on the system configuration, possibly require an additional craftsperson in another location. 1.4 If this procedure is reissued, a summary of the changes will appear in this paragraph. 2 1 B A 1 4 3 B A 2 6 5 B A 3 8 7 B A 4 10 9 B A 5 12 11 B A 6 VOID W A R R A N T Y Port Tap Module M Part Number: Serial MADE IN MEXICO US PATENT NO. TAP LIVE Figure 1 HPA-0753 related literature | SRP-003-794, Pretium EDGE ® Solution SRP-006-136, Multifiber Connector and Port Cleaning with the TKT-CLEAN-MFC-M kit table of contents | 1. General .................................................................................................................................................1 2. Precautions ...........................................................................................................................................2 3. Tools and Materials ...............................................................................................................................2 4. Connector and Adapter Cleaning ..........................................................................................................2 5. Calculating System Loss .Budgets .......................................................................................................3 6. The Functionality of the Tap Module Splitters .......................................................................................5 7. Installing Pretium EDGE Tap Modules ...................................................................................................6 8. Referencing the Test Equipment for a Tap Module ...............................................................................6 9. Testing Pretium EDGETap Modules .....................................................................................................8

Upload: others

Post on 17-Nov-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Pretium EDGE Tap Module Installation and Testing

SRP 003-126, Issue 1

STANDARD RECOMMENDED PROCEDURE 003-126 | ISSUE 1 | OCTOBER 2012| PAGE 1 OF 9

| PR

ETE

RM

INAT

ED

SY

STE

MS

| C

AB

LES

| C

ON

NE

CTO

RS

| C

AB

LE A

SS

EM

BLI

ES

| H

AR

DW

AR

E |

TOO

L K

ITS

AN

D A

CC

ES

SO

RIE

S |

TES

T E

QU

IPM

EN

T | S

PLI

CE

EQ

UIP

ME

NT

| FA

N-O

UT

KIT

S |

Pretium EDGE® Tap ModuleInstallation and Testing

1. General

1.1 This procedure describes Pretium EDGE Tap Modules, which are available for both multimode and single mode applications. Compatible with all Pretium EDGE rack-mountable connector housings, TAP modules have twelve front-mounted shuttered LC adapters and two MTP® connectors in back (Figure 1).

1.2 Themodulecontains12fiberopticsplitterswhichdividetheincomingopticalsignalsintotwooutputs,oneforlivelinktrafficandoneformonitoring.Themonitortrafficisroutedviathe“TAP”-labeledMTPconnectortoamonitoringdevicewhichfiltersthedataandsendsittovarioussoftwaretoolsforanalysis, where it is then viewed in application-layer software for security threats, performance issues, or system optimization.

IMPORTANT: Please note that Tap module systems have two outputs for each input, which may requiretwopowermeters,anddependingonthesystemconfiguration,possiblyrequireanadditionalcraftsperson in another location.

1.4 If this procedure is reissued, a summary of the changes will appear in this paragraph.

21

B

A

1

43

B

A

2

65

B

A

3

87

B

A

4

109

B

A

5

1211

B

A

6

VOID

WARRANTY

Port Tap Module

MPart Number:

Serial MADE IN MEXICO

US PATENT NO.

TAP

LIVE

Figure 1HPA-0753

related literature |

SRP-003-794, Pretium EDGE® Solution

SRP-006-136,MultifiberConnectorandPortCleaningwiththeTKT-CLEAN-MFC-Mkit

table of contents |1. General .................................................................................................................................................12. Precautions ...........................................................................................................................................23. Tools and Materials ...............................................................................................................................24. Connector and Adapter Cleaning ..........................................................................................................25. Calculating System Loss .Budgets .......................................................................................................36. The Functionality of the Tap Module Splitters .......................................................................................57. Installing Pretium EDGE Tap Modules ...................................................................................................68. Referencing the Test Equipment for a Tap Module ...............................................................................6

9. Testing Pretium EDGETap Modules .....................................................................................................8

Page 2: Pretium EDGE Tap Module Installation and Testing

STANDARD RECOMMENDED PROCEDURE 003-126 | ISSUE 1 | OCTOBER 2012 | PAGE 2 OF 9

2. Precautions2.1 Laser Precautions

\WARNING:DONOTusemagnifiersinthepresenceoflaserlight-diffusedlaserlightcancauseeyedamageoffocusedwithopticalinstruments.Neverlookdirectlyintotheendofaconnectorthatmaybe carrying laser light. Should accidental eye exposure to laser light be suspected, arrange for an eye examination immediately

2.2 Cable Handling Precautions

NOTE: Fiber optic cable is sensitive to excessive pulling, bending, and crushing forces. Do not bend cables more sharply than their minimum recommended bend radius. Do not apply more pulling forcetothecableassemblythanspecified.Donotcrushthecableorallowittokink.Doingsomaycause damage that can alter the transmission characteristics of the cable; the cable may have to be replaced.

3. Tools and Materials

3.1 The following tools and materials are required for this procedure: •Two(2)powermeterswithLCportadapters

•Two(2)LC-LCjumpers

•One(1)SC-LCjumperforthelightsource

•One(1)LC-LCadapter •Lightsource •OneMTPtoLCharness •LCportcleaner(p/nCLEANER-PORT-LC) •MTPConnectorandPortCleaningTool(p/n2104466-01)

For multimode applications:

•Mandrelwrapsuitableforyourcabletype(availableinp/nOTS-COMBOMAN)

4. Connector and Adapter Cleaning

4.1 Cleaning the LC adapters with an LC port cleaner before each mating is recommended (Figure 2).

4.2 The use of an MTP Connector and Port Cleaning Tool to clean MTP connectors and ports before each mating is recommended (Figure 3).

Figure 2HPA-0738

Figure 3HPA-0754

Page 3: Pretium EDGE Tap Module Installation and Testing

STANDARD RECOMMENDED PROCEDURE 003-126 | ISSUE 1 | OCTOBER 2012 | PAGE 3 OF 9

5. Calculating System Loss Budgets

5.1 This section describes how to calculate the loss budgets of a system using a Pretium EDGE Tap Module.NotethatyouwillneedtocalculateonelossbudgetfortheLIVEsystem(Figure4)and two different loss budgets for the Tap output (Figure 5 and 6).

Table 1 indicates the system loss values of the system components:

Table 1

5.2. To calculate the system losses, add the loss values of the components as illustrated in the examples shown in Figures 4, 5, and 6.

Multimode Fiber Single Mode Fiber

OM4

Ultra-bendable

optimized 50µm

(850 nm)

Bend-improved

single Mode

(1310 nm)

Component Loss, max (dB)1 Loss, max (dB)1

MTP® mated pair loss 0.35 0.75LC mated pair loss 0.15 0.5Splitter 50/50 (dB) 3.8 3.6Splitter 30/70 (dB) 6.6 /1.8 6.0 / 2.0

1 Insertion loss specifications when mated to other system components of a like performance specification

B

6 1211

AB

5 109

AB

4 87

AB

3 6

Port Tap M

odule

Part N

umber

Serial

MA

DE

IN M

EX

ICO

TAP

LIV

E

5

AB

2 43

AB

1 21

A

WAR

RAN

TY

VO

ID

Tap Module “A”Pretium EDGE Module “B”HPA-0825

Figure 4

“Near end” “Far end”

Budget loss for a LIVE multimode system using OM4 fiber and 50 /50 splitters:

0.15 0.35 0.353.8 0.15+ + +

LC mated pair

LC mated pair

50/50 splitter

MTP mated pair

MTP mated pair

0.15 +3.8 + 0.35 +0.35 + 0.15 = 4.8 dB + fiber loss

Note: Fiber lossdepends on length of system

B

612

11

A

B

510

9

A

B

48

7

A

B

36

PnP

Mod

ule

Part

Num

ber

Seria

lM

ADE

IN M

EXIC

O

5

A

B

24

3

A

B

12

1

A

WAR

RANTY

VOID

Page 4: Pretium EDGE Tap Module Installation and Testing

STANDARD RECOMMENDED PROCEDURE 003-126 | ISSUE 1 | OCTOBER 2012 | PAGE 4 OF 9

B

6 1211

AB

5 109

AB

4 87

AB

3 6

Port Tap M

odule

Part N

umber

Serial

MA

DE

IN M

EX

ICO

TAP

LIV

E

5

AB

2 43

AB

1 21

A

WAR

RAN

TY

VO

ID

Tap port test harness

Tap Module “A”

HPA-0826

Figure 5

“Near end”

Budget loss for a “Near end” Tap port test harness multimode system using OM4 fiber and 50 /50 splitters:

0.15

0.35

3.8

0.15

++

+

LC mated pair

LC mated pair

50/50 splitter

MTP mated pair

0.15 +3.8 + 0.35 + 0.15 = 4.45 dB + fiber loss

Note: Fiber lossdepends on length of system

B

6 1211

AB

5 109

AB

4 87

AB

3 6

Port Tap M

odule

Part N

umber

Serial

MA

DE

IN M

EX

ICO

TAP

LIV

E

5

AB

2 43

AB

1 21

A

WAR

RAN

TY

VO

ID

Tap Module “A”Pretium EDGE Module “B”

HPA-0827 Figure 6

“Far end”“Near end”

Budget loss for a “Far end” to Tap Port harness multimode system using OM4 fiber and 50 /50 splitters:

0.35 0.35

0.35

3.8 0.15

0.15

+

+

+

+ +

LC mated pair

LC mated pair

50/50 splitter

MTP mated pair

MTP mated pair

MTP mated pair

Tap port test harenss

0.15 +3.8 + 0.35 + 0.35 + .035 + 0.15 = 5.15 dB + fiber loss

B

612

11

A

B

510

9

A

B

48

7

A

B

36

PnP

Mod

ule

Part

Num

ber

Seria

lM

ADE

IN M

EXIC

O

5

A

B

24

3

A

B

12

1

A

WAR

RANTY

VOID

Note: Fiber lossdepends on length of system

Page 5: Pretium EDGE Tap Module Installation and Testing

STANDARD RECOMMENDED PROCEDURE 003-126 | ISSUE 1 | OCTOBER 2012 | PAGE 5 OF 9

6. The Functionality of the Tap Module SplittersDirectionality

6.1 Insimplestterms,thesplittersinsideaTapmoduleactlikeadividerofaone-waytrafficflow–inthiscase, light.

The even-numbered LC connectors in a Tap module serve only for source inputandtheirtrafficissplitbetweentheLIVEandTAPoutputs(Figure7,top).

In the same fashion, the Tap module’s odd-numbered LC connectors receivelivetrafficfromtheLIVEMTPinputport.TheinputtrafficfromtheLIVEinputportissplitbetweentheLIVELCoddfibersandtheMTPTAPport(Figure7,bottom).

Tables 2 and 3 in Section 9 provide a full representation of the source and output positions

6.2 Tap modules therefore must be tested with directionality in mind. The source must be always connected to the input of the splitter and the meter must be connected to the output of the splitter. Connecting a source to the output of a splitter will result in high attenuation.

Wavelength Considerations

6.3 Thesplittersonmultimodemodulesareoptimizedfor850nmVCSEL(Vertical-cavitySurface-emittingLasers), thus when testing multimode systems, use only the 850 nm wavelength.

6.4 Single mode systems may be tested at both 1310 and 1550 nm.

B

6 1211

AB

5 109

AB

4 87

AB

3 6

TAP

LIV

E

5

AB

2 43

AB

1 21

A

WAR

RAN

TY

VO

ID

Input into LC # 2

Live output from LC # 1

LIVE output

HPA-0755

Tap Outputon MTP Fiber 1 TAP

Output

TAPOutput

B

6 1211

AB

5 109

AB

4 87

AB

3 6

TAP

LIV

E

5

AB

2 43

AB

1 21

A

WAR

RAN

TY

VO

ID

LIVE source

Figure 7

Tap Outputon MTP Fiber 2

Page 6: Pretium EDGE Tap Module Installation and Testing

STANDARD RECOMMENDED PROCEDURE 003-126 | ISSUE 1 | OCTOBER 2012 | PAGE 6 OF 9

7. Installing a Pretium EDGE Tap Module

7.1 PretiumEDGETapmodulesareinstalledjustliketheirnormalPretiumEDGEmodulecounterparts.Refer to the Installation chapter in SRP-003-794, Pretium EDGE Solution, for complete instructions. This procedure covers module installation, trouble shooting, and other module-related topics as well.

7.2 Install the Tap module and its Tap MTP harness into your system housing (this procedure illustrates an MTP to LC harness).

8. Referencing the Test Equipment for a Tap Module

8.1 Start by powering on the source and meter and allowing a minimum of 5 minutes for them to warm up and stabilize.

For multimode systems: set the unit to the 850 nm wavelength.

For single mode systems: Set the unit to auto-switch between 1310 and 1550 nm wavelengths.

8.2 To reference the source and two meters:

Step 1: Clean and insert the SC-end of the SC toLCjumper(ReferenceJumperno.1,or RJ1) into the output of the light source.

Step 2: Clean and insert the LC end of RJ1 jumperintotheLCportadapterofMeter no. 1 (M1) (Figure 8).

For multimode only:Wrapthejumper5timesand secure it in a 25 mm mandrel with tape (standard 50 µm multimode procedure).

Step 3: VerifythatRJ1 is acceptable at your system’s wavelength(s) and reference this power to 0.00 dB.

Step 4: Disconnect and move the meter-end LC of RJ1 to Meter no. 2 (M2) and repeat step 3. Disconnect M2 after this step.

Step 5: Clean and insert the LC end of RJ1 into an LC adapter.

Light Source (Tx)

Do NOT disconnect

Figure 8

HPA-0758

Meter no. 1 (RX)

Meter no. 2 (RX) M2

0.00

22 mm mandrel wrap for multimode only

Reference Jumper no.1 RJ1

M1

Page 7: Pretium EDGE Tap Module Installation and Testing

STANDARD RECOMMENDED PROCEDURE 003-126 | ISSUE 1 | OCTOBER 2012 | PAGE 7 OF 9

Step 6: CleanandinstallanLCtoLCjumper- ReferenceJumperno.2(RJ2) into M1 and the LC adapter (Figure 9).

Step 7: VerifythattheRJ1/ RJ2 mated pair are acceptablewithaloss≤0.15dB.

Step 8: Disconnect RJ2’s LC connector from the LC adapter and protect it with a clean dust cap until you are ready to start the system testing.

Step 9: CleanandinstallanLCtoLCjumper- ReferenceJumperno.3(RJ3) into M2 and the LC adapter (Figure 10).

Step 10: VerifythattheRJ1/RJ3 mated pair are acceptablewithaloss≤0.15dB.

Step 11: Disconnect RJ1’s LC connector from the LC adapter and protect it with a clean dust cap.

Step 12: Leave the LC adapter on the end of RJ3 for the remainder of this procedure since it will be required for mating to the TAP port test harness.

8.3 Referencing is now complete. Move the Light Source and RJ1 to the front of the Tap module; move M2, RJ3, and the LC adapter to the end of the Tap harness; and move M1 and RJ2 to the Pretium EDGE modules at the far end of the system (See Figure 11).

IMPORTANT: Fromthisstepon,doNOTdisconnecttheconnectorsoneithertheLightSourceormeterportadapters.

Do NOT disconnect

Do NOT disconnect

Figure 9 HPA-0759

LC adapter

0.15 dB

multimode only

RJ1 Reference Jumper no. 2 RJ2

M1 Light Source

Do NOT disconnect

Light Source

M1

Figure 10 HPA-0760

LC adapter

Dust cap

RJ2 Do NOT disconnect

0.3 dB

multimode only

RJ 1

RJ3

M2

0.15 dB

Page 8: Pretium EDGE Tap Module Installation and Testing

STANDARD RECOMMENDED PROCEDURE 003-126 | ISSUE 1 | OCTOBER 2012 | PAGE 8 OF 9

9. Testing Pretium EDGE Tap Modules

9.1 Table 2 provides a complete guide to the testing sequence for testing with the light source at the Tap module“A”(“Nearend”)andameteratModule“B”,orthe“Farend”ofthesystemshowninFigure11.

Source LC Position at “A' Module “B” LC Position Meter no. 2 -TAP Port Test HarnessA-2 B-1 1A-4 B-3 3A-6 B-5 5A-8 B-7 7A-10 B-9 9A-12 B-11 11

Table 2

9.2 To begin testing a Tap module (Figure 11):

Step 1: Install the Light Source/RJ1 LC connector into LC number 2 port of the Tap module.

Step 2: Install RJ2’sLCconnectorintothenumber1portofthePretiumEdgemodule(Module“B”in Figure 11).

Step 3: Install LC connector number 1 from the Tap port test harness into the LC adapter on the end of RJ3.

Step 4: Saveorrecordthefirstfiber’smeasurements.Thereadingwillbethetotalsystemloss.

B

6 1211

AB

5 109

AB

4 87

AB

3 6

Port Tap M

odule

Part N

umber

Serial

MA

DE

IN M

EX

ICO

TAP

LIV

E

5

AB

2 43

AB

1 21

A

WAR

RAN

TY

VO

ID

Light Source

Tap port test harness

Link under test

M1

M2

RJ2 RJ1

Do NOT disconnect

Do NOT disconnect

0.00 dB

0.00 dB

Tap Module “A”

Pretium EDGE Module “B”

B

23

B

12

1

A

B

2 43

AB

1 21

A

11

1

HPA-0757

Figure 11

multimode only

Do NOT disconnect

RJ3

“Near end”“Far end”

B

61211

AB

5109

AB

48

7

AB

36

PnP

Mod

ule

Par

t Num

ber

Ser

ial

MA

DE

IN M

EX

ICO

5

AB

24

3

AB

12

1

A

WAR

RAN

TY

VO

ID

Page 9: Pretium EDGE Tap Module Installation and Testing

STANDARD RECOMMENDED PROCEDURE 003-126 | ISSUE 1 | OCTOBER 2012 | PAGE 9 OF 9

Corning Cable Systems LLC • PO Box 489 • Hickory, NC 28603-0489 USA 1-800-743-2671 • FAX +1-828-325-5060 • International +1-828-901-5000 • http://www.corning.com/cablesystems

CorningCableSystemsreservestherighttoimprove,enhance,andmodifythefeaturesandspecificationsofCorningCableSystems’productswithoutpriornotification.Pretium EDGE is a registered trademark of Corning Cable Systems Brands, Inc. MTP is a registered trademark of USConec, Ltd. All other trademarks are the properties of theirrespectiveowners.CorningCableSystemsisISO9001certified.

©2012 Corning Cable Systems. All rights reserved. Published in the USA.

9.3 Table3providesacompleteguidetothetestingsequencefortestingwiththeLightSourceatthe“B”module(“Farend”)andameteratTapmodule“A”(“Nearend”)ofthesystemasshowninFigure12.

Source LC Position at “B” Meter no.1 LC Position at “A”: Meter no. 2 -TAP Port Test HarnessB-2 A-1 2B-4 A-3 4B-6 A-5 6B-8 A-7 8B-10 A-9 10B-12 A-11 12

Table 3

9.4 Totesttheodd-numberedportsatthefrontoftheTapModule,switchthe“Near”and“Far”locationsofthe Light Source/RJ1 and M1/RJ2. At the end of the Tap cable assembly, move the LC adapter on M2/RJ3 to connector number 2 (Figure 12).

9.5 TocompletethetestingofthefirstTapmodule,saveorrecordeachfiber’smeasurementsasyoufollow the sequence shown in Table 3.

9.6 Repeat the steps in this section on the remaining Tap modules.

B

6 1211

AB

5 109

AB

4 87

AB

3 6

Port Tap M

odule

Part N

umber

Serial

MA

DE

IN M

EX

ICO

TAP

LIV

E

5

AB

2 43

AB

1 21

A

WAR

RAN

TY

VO

ID

Light Source Tap port test harness

Link under test RJ2

M1

M2

RJ1

0.00 dB

0.00 dB

B

61211

AB

5109

AB

48

7

AB

36

PnP

Mod

ule

Par

t Num

ber

Ser

ial

MA

DE

IN M

EX

ICO

5

AB

24

3

AB

12

1

A

WAR

RAN

TY

VO

ID

Tap Module “A”

Pretium EDGE Module “B”

B

23

B

12

1

A

B

2 43

AB

1 21

A

12

RJ3 and adapter

2

HPA-0761

Figure 12

multimode only

“Near end”“Far end”