Pressure Vessel API 510 EXTERNAL INSPECTION
IN-SERVICE INSPECTION REPORT
FL5 No. 2 Flash Tank 50-2024WestRock
Evadale, TX13-January-2021
Prepared by: Stuart A Vawter
OilPatchAIS312 Richey St.
Pasadena, Tx 77506 281-532-5750
www.OilPatchNDT.com
Pressure Vessel
API 510 EXTERNAL INSPECTION IN-SERVICE INSPECTION REPORT
Client WestRock Location Evadale, Tx Area No. 5 Fiberline (WRE) Date 13-January-2021
Equip # 50-2024 Inspector Stuart A Vawter Description FL5 No. 2 Flash Tank Certification API 510 #42697
Table of Contents
API 510 External Visual In-Service Inspection Report
External Visual Inspection Checklist
Photographs
Pressure Vessel
API 510 EXTERNAL INSPECTION IN-SERVICE INSPECTION REPORT
Client WestRock Location Evadale, Tx Area No. 5 Fiberline (WRE) Date 13-January-2021
Equip # 50-2024 Inspector Stuart A Vawter Description FL5 No. 2 Flash Tank Certification API 510 #42697
Scope of Inspection: An API 510 In-service external visual inspection was performed on 01/13/2021. Equipment Access: Ground and decks. Accessed on 2nd, 3rd and 4th floor of No. 5 FL structure. Summary of Results: An API 510 In-service External Visual inspection was performed on 50-2024 and accessible components. The Carbon-Steel vessel showed no signs of bulges or blisters noted at the time of inspection. Flange leak noted on southside near top head (Reported to client immediately) Housekeeping (Combustible debris and trash) noted on and around vessel. Damaged insulation, broken insulation bands, and missing inspection plugs noted. There were no other findings that would render the tank unfit for continued service at time of inspection. Description: Carbon-Steel. (U1A) Outside Diameter 18’-6”, Over All Height 46’-9” (DRW) Corrosion Allowance 0.375” (U1A) Design pressure: 30 PSIG with Full Vacuum. (U1A) Built in 1993. (U1A)
Pressure Vessel
API 510 EXTERNAL INSPECTION IN-SERVICE INSPECTION REPORT
Client WestRock Location Evadale, Tx Area No. 5 Fiberline (WRE) Date 13-January-2021
Equip # 50-2024 Inspector Stuart A Vawter Description FL5 No. 2 Flash Tank Certification API 510 #42697
Priority Flange leak noted on southside near top head (Reported to client immediately) 2
Housekeeping (Combustible debris and trash) noted on and around vessel. 3
Damaged insulation, broken insulation bands, and missing inspection plugs noted. 3
Priority 1 = High likelihood and consequence of failure. Critical code or standard deficiency. May not be fit for continued
service without action. Priority 2 = Medium likelihood and consequence of failure. Repair may be needed for continued effective service. Priority 3 = Low likelihood and consequence of failure. Non-critical code or standard deficiency. Industry best practice
or preventative maintenance. Housekeeping items.
Next Recommended Inspection: Based on the continued use in this service and due to findings in above report it is recommended: Based on the continued use it is recommended: External Visual in 5 year on or before 13-January-2026
Pressure Vessel
API 510 EXTERNAL INSPECTION IN-SERVICE INSPECTION REPORT
Client WestRock Location Evadale, Tx Area No. 5 Fiberline (WRE) Date 13-January-2021
Equip # 50-2024 Inspector Stuart A Vawter Description FL5 No. 2 Flash Tank Certification API 510 #42697
Observations: N
/A
AC
CEP
TAB
LE
NO
T A
CC
EPTA
BLE
FUR
THER
INSP
ECT
Inspection Comments
External Visual Inspection
General
V1. Nameplate, Manufacturer Data Sheet and P&ID have
corresponding information. Manufacture nameplate noted and legible
V2. Corrosion
V3. Leaks YES NO Flange leaks noted on vessel at the time of inspection. Reported to
client immediately.
V4. Vibration
V5. Dissimilar Flange Rating YES
NO
V6. Ladder/Stairway
V7. Platform
V8. Guy Wires
V9. Electrical Ground None noted at time of inspection
V10. Coating/Painting
V11. Expansion Joints or Bellows
V12. Gauge/Site Glass
V13. Shell/Headers/Channels Fully Insulated.
V14. Heads Fully Insulated.
Supports
V15. Foundation
V16. Anchor Bolts .
V17. Saddle/Skirt
Pressure Vessel
API 510 EXTERNAL INSPECTION IN-SERVICE INSPECTION REPORT
Client WestRock Location Evadale, Tx Area No. 5 Fiberline (WRE) Date 13-January-2021
Equip # 50-2024 Inspector Stuart A Vawter Description FL5 No. 2 Flash Tank Certification API 510 #42697
Observations:
N/A
AC
CEP
TAB
LE
NO
T A
CC
EPTA
BLE
FU
RTH
ER IN
SPEC
T
Inspection Comments
V18. Coating/Paint deterioration
V19. Davit
V20. Fireproofing
Connections
V21. Small Branches
V22. Nozzles
V23. Manways
V24. Reinforcing Pads Fully insulated
V25. Inadequate Thread Engagement YES NO
V26. Bolting
V27. Flanges .
Insulation
V28. Jacket Missing insulation plugs
V29. Banding Broken band near top head
V30. Seals/Joints
Relief Devices
V32. Two PRD‘s noted but had no access to them at time of
inseption
SET PRESSURE:
PRD NAME:
NOTES:
.
Inspected by: _Stuart A Vawter_
Company: __OilPatch AIS__
Date: 01/13/21
API 510 Cert. # __42697__
Signature: Stuart A Vawter
Pressure Vessel
API 510 EXTERNAL INSPECTION IN-SERVICE INSPECTION REPORT
Client WestRock Location Evadale, Tx Area No. 5 Fiberline (WRE) Date 13-January-2021
Equip # 50-2024 Inspector Stuart A Vawter Description FL5 No. 2 Flash Tank Certification API 510 #42697
REFERENCE PHOTOGRAPHS
Overall View
Pressure Vessel
API 510 EXTERNAL INSPECTION IN-SERVICE INSPECTION REPORT
Client WestRock Location Evadale, Tx Area No. 5 Fiberline (WRE) Date 13-January-2021
Equip # 50-2024 Inspector Stuart A Vawter Description FL5 No. 2 Flash Tank Certification API 510 #42697
Nameplate
Pressure Vessel
API 510 EXTERNAL INSPECTION IN-SERVICE INSPECTION REPORT
Client WestRock Location Evadale, Tx Area No. 5 Fiberline (WRE) Date 13-January-2021
Equip # 50-2024 Inspector Stuart A Vawter Description FL5 No. 2 Flash Tank Certification API 510 #42697
Typical top head viewed thru grating.
Pressure Vessel
API 510 EXTERNAL INSPECTION IN-SERVICE INSPECTION REPORT
Client WestRock Location Evadale, Tx Area No. 5 Fiberline (WRE) Date 13-January-2021
Equip # 50-2024 Inspector Stuart A Vawter Description FL5 No. 2 Flash Tank Certification API 510 #42697
“R”-Stamp Nameplate
Pressure Vessel
API 510 EXTERNAL INSPECTION IN-SERVICE INSPECTION REPORT
Client WestRock Location Evadale, Tx Area No. 5 Fiberline (WRE) Date 13-January-2021
Equip # 50-2024 Inspector Stuart A Vawter Description FL5 No. 2 Flash Tank Certification API 510 #42697
Typical Lower Cone Condition 2nd Nameplate
Pressure Vessel
API 510 EXTERNAL INSPECTION IN-SERVICE INSPECTION REPORT
Client WestRock Location Evadale, Tx Area No. 5 Fiberline (WRE) Date 13-January-2021
Equip # 50-2024 Inspector Stuart A Vawter Description FL5 No. 2 Flash Tank Certification API 510 #42697
Broken Insulation bands Damaged Insulation
Missing Insulation plugs
Pressure Vessel
API 510 EXTERNAL INSPECTION IN-SERVICE INSPECTION REPORT
Client WestRock Location Evadale, Tx Area No. 5 Fiberline (WRE) Date 13-January-2021
Equip # 50-2024 Inspector Stuart A Vawter Description FL5 No. 2 Flash Tank Certification API 510 #42697
Housekeeping (Trash amd combustiable material on and around vessel)
Pressure Vessel
API 510 EXTERNAL INSPECTION IN-SERVICE INSPECTION REPORT
Client WestRock Location Evadale, Tx Area No. 5 Fiberline (WRE) Date 13-January-2021
Equip # 50-2024 Inspector Stuart A Vawter Description FL5 No. 2 Flash Tank Certification API 510 #42697
Flange Leak Reproted to client
Pressure Vessel
API 510 EXTERNAL INSPECTION IN-SERVICE INSPECTION REPORT
Client WestRock Location Evadale, Tx Area No. 5 Fiberline (WRE) Date 13-January-2021
Equip # 50-2024 Inspector Stuart A Vawter Description FL5 No. 2 Flash Tank Certification API 510 #42697
Signage